[{"data":1,"prerenderedAt":1266},["ShallowReactive",2],{"blog-post-fr-plan-de-situation":3,"blog-alternates-what-is-a-situation-plan":302},{"id":4,"title":5,"articleId":6,"body":7,"category":276,"date":277,"description":278,"extension":279,"lastUpdated":280,"locale":281,"meta":282,"navigation":283,"path":284,"publishDate":277,"readTime":285,"refreshInterval":286,"seo":287,"slug":288,"stem":289,"tags":290,"__hash__":301},"blog\u002Fblog\u002Fwhat-is-a-situation-plan.fr.md","Qu'est-ce qu'un plan de situation ?","what-is-a-situation-plan",{"type":8,"value":9,"toc":264},"minimark",[10,15,33,40,44,61,110,113,117,122,153,157,237,240,244,258],[11,12,14],"h2",{"id":13},"un-plan-au-sol-de-votre-installation-électrique","Un plan au sol de votre installation électrique",[16,17,18,19,23,24,27,28,32],"p",{},"Le plan de situation (néerlandais : ",[20,21,22],"em",{},"situatieschema",", allemand : ",[20,25,26],{},"Situationsplan",") est un plan simplifié du bâtiment montrant la ",[29,30,31],"strong",{},"position physique"," du matériel électrique pertinent — prises, interrupteurs, luminaires, tableaux et appareils fixes. Aucune échelle universelle n'est imposée ; la lisibilité et l'absence d'ambiguïté sont essentielles.",[16,34,35,36,39],{},"Contrairement au schéma unifilaire, le plan de situation ne montre pas la hiérarchie logique des circuits, mais ",[29,37,38],{},"où exactement"," tout se trouve.",[11,41,43],{"id":42},"que-dit-le-rgie","Que dit le RGIE ?",[16,45,46,47,54,55,60],{},"La ",[48,49,53],"a",{"href":50,"rel":51},"https:\u002F\u002Feconomie.fgov.be\u002Ffr\u002Fthemes\u002Fenergie\u002Fsources-et-vecteurs-denergie\u002Felectricite\u002Fsecurite-et-controle-des\u002Fcontrole-des-installations",[52],"nofollow","page officielle du SPF Economie sur le contrôle domestique"," cite le schéma unifilaire et le plan de situation parmi les documents à remettre au minimum. Le ",[48,56,59],{"href":57,"rel":58},"https:\u002F\u002Feconomie.fgov.be\u002Fsites\u002Fdefault\u002Ffiles\u002FFiles\u002FPublications\u002Ffiles\u002FRGIE-Annexe-Livre-1-Installations-a-basse-tenstion-et-a-tres-basse-tension-2026.pdf",[52],"Livre 1 du RGIE en vigueur"," précise leur contenu et leurs repères communs :",[62,63,64,80],"table",{},[65,66,67],"thead",{},[68,69,70,74,77],"tr",{},[71,72,73],"th",{},"Document",[71,75,76],{},"Article RGIE",[71,78,79],{},"Montre",[81,82,83,97],"tbody",{},[68,84,85,91,94],{},[86,87,88],"td",{},[29,89,90],{},"Schéma unifilaire",[86,92,93],{},"Art. 9.1.2 Nr. 1",[86,95,96],{},"Structure logique — dispositifs de protection, circuits, hiérarchie",[68,98,99,104,107],{},[86,100,101],{},[29,102,103],{},"Plan de situation",[86,105,106],{},"Art. 9.1.2 Nr. 2",[86,108,109],{},"Position physique — où tout est installé dans le bâtiment, y compris l'emplacement du compteur et du système de mise à la terre",[16,111,112],{},"Les documents doivent correspondre à l'installation réelle. Des plans absents ou contradictoires peuvent être repris comme infraction ; seul l'organisme agréé établit la conclusion officielle.",[11,114,116],{"id":115},"que-doit-contenir-le-plan-de-situation","Que doit contenir le plan de situation ?",[118,119,121],"h3",{"id":120},"liste-de-vérification","Liste de vérification",[123,124,125,129,132,135,138,141,144,147,150],"ul",{},[126,127,128],"li",{},"Plan simplifié et lisible de chaque étage concerné",[126,130,131],{},"Position de toutes les prises (simple, double, avec terre)",[126,133,134],{},"Position de tous les interrupteurs (on\u002Foff, va-et-vient, variateur)",[126,136,137],{},"Points lumineux (plafond, mur, extérieur)",[126,139,140],{},"Tableau de distribution et emplacement du compteur",[126,142,143],{},"Appareils fixes (plaque de cuisson, chauffe-eau, borne de recharge)",[126,145,146],{},"Emplacement non ambigu du matériel référencé au schéma unifilaire",[126,148,149],{},"Numéros de référence des circuits (doivent correspondre au schéma unifilaire)",[126,151,152],{},"Symboles appropriés du tableau 2.23 du RGIE (chapitre 2.13)",[11,154,156],{"id":155},"plan-de-situation-vs-schéma-unifilaire","Plan de situation vs. schéma unifilaire",[62,158,159,170],{},[65,160,161],{},[68,162,163,166,168],{},[71,164,165],{},"Propriété",[71,167,103],{},[71,169,90],{},[81,171,172,183,194,204,215,226],{},[68,173,174,177,180],{},[86,175,176],{},"Représentation",[86,178,179],{},"Plan au sol physique",[86,181,182],{},"Schéma logique des circuits",[68,184,185,188,191],{},[86,186,187],{},"Montre la position ?",[86,189,190],{},"Oui — emplacement exact",[86,192,193],{},"Non",[68,195,196,199,201],{},[86,197,198],{},"Montre la hiérarchie ?",[86,200,193],{},[86,202,203],{},"Oui — du réseau au consommateur",[68,205,206,209,212],{},[86,207,208],{},"Dispositifs de protection",[86,210,211],{},"Position uniquement",[86,213,214],{},"Calibres, type, coordination",[68,216,217,220,223],{},[86,218,219],{},"Info câbles",[86,221,222],{},"Chemins visibles",[86,224,225],{},"Type et section indiqués",[68,227,228,231,234],{},[86,229,230],{},"À l'échelle",[86,232,233],{},"Pas d'échelle universelle ; lisible et sans ambiguïté",[86,235,236],{},"Non coté à l'échelle",[16,238,239],{},"Les deux documents se complètent et sont également obligatoires.",[11,241,243],{"id":242},"articles-connexes","Articles connexes",[123,245,246,252],{},[126,247,248],{},[48,249,251],{"href":250},"\u002Ffr\u002Fblog\u002Fschema-unifilaire","Créer un schéma unifilaire — étape par étape",[126,253,254],{},[48,255,257],{"href":256},"\u002Ffr\u002Fblog\u002Fcout-plan-electrique","Combien coûte un plan électrique en Belgique ?",[16,259,260],{},[48,261,263],{"href":262},"\u002F","Créez votre plan de situation avec PlanElec — gratuit →",{"title":265,"searchDepth":266,"depth":266,"links":267},"",2,[268,269,270,274,275],{"id":13,"depth":266,"text":14},{"id":42,"depth":266,"text":43},{"id":115,"depth":266,"text":116,"children":271},[272],{"id":120,"depth":273,"text":121},3,{"id":155,"depth":266,"text":156},{"id":242,"depth":266,"text":243},"faq","2026-03-06","Le plan de situation montre où tous les composants électriques sont physiquement installés dans votre bâtiment. Découvrez ce qu'il doit contenir et comment il se distingue du schéma unifilaire.","md","2026-08-29","fr",{},true,"\u002Fblog\u002Fwhat-is-a-situation-plan.fr","3 min",12,{"title":5,"description":278},"plan-de-situation","blog\u002Fwhat-is-a-situation-plan.fr",[291,292,293,22,26,294,295,296,297,298,299,300],"AREI","RGIE","plan de situation","situation plan","schéma unifilaire","eendraadschema","Eindrahtschema","contrôle électrique","plan au sol","Belgique","C0nI_Vt_a9zOgViA9ATEI6ri8t5FF9JKFGPnVfaTAEc",[303,565,827,1008],{"id":304,"title":305,"articleId":6,"body":306,"category":276,"date":277,"description":551,"extension":279,"lastUpdated":280,"locale":552,"meta":553,"navigation":283,"path":554,"publishDate":277,"readTime":285,"refreshInterval":286,"seo":555,"slug":556,"stem":557,"tags":558,"__hash__":564},"blog\u002Fblog\u002Fwhat-is-a-situation-plan.de.md","Was ist ein Situationsplan?",{"type":8,"value":307,"toc":542},[308,312,325,332,336,349,388,391,395,399,432,436,516,519,523,537],[11,309,311],{"id":310},"ein-grundriss-ihrer-elektroinstallation","Ein Grundriss Ihrer Elektroinstallation",[16,313,314,315,317,318,320,321,324],{},"Der Situationsplan (niederländisch: ",[20,316,22],{},", französisch: ",[20,319,293],{},") ist ein vereinfachter Grundriss Ihres Gebäudes, auf dem die ",[29,322,323],{},"physische Position"," der relevanten elektrischen Komponenten eingezeichnet ist — etwa Steckdosen, Schalter, Leuchten, Verteiler und feste Geräte. Ein bestimmter Maßstab ist nicht pauschal vorgeschrieben; der Plan muss vor allem lesbar und eindeutig sein.",[16,326,327,328,331],{},"Anders als das Eindrahtschema zeigt der Situationsplan nicht die logische Schaltungshierarchie, sondern ",[29,329,330],{},"wo genau"," sich alles befindet.",[11,333,335],{"id":334},"was-sagt-das-arei","Was sagt das AREI?",[16,337,338,339,343,344,348],{},"Die ",[48,340,342],{"href":50,"rel":341},[52],"offizielle Übersicht des SPF Economie zur häuslichen Elektrokontrolle"," nennt Eindrahtschema und Situationsplan als mindestens vorzulegende Unterlagen. Das aktuelle ",[48,345,347],{"href":57,"rel":346},[52],"AREI\u002FRGIE Buch 1"," beschreibt Inhalt und gemeinsame Referenzen:",[62,350,351,364],{},[65,352,353],{},[68,354,355,358,361],{},[71,356,357],{},"Dokument",[71,359,360],{},"AREI-Artikel",[71,362,363],{},"Zeigt",[81,365,366,377],{},[68,367,368,372,374],{},[86,369,370],{},[29,371,297],{},[86,373,93],{},[86,375,376],{},"Logische Struktur — Schutzgeräte, Stromkreise, Hierarchie",[68,378,379,383,385],{},[86,380,381],{},[29,382,26],{},[86,384,106],{},[86,386,387],{},"Physische Position — wo ist alles im Gebäude installiert, inkl. Lage des Zählerkastens und der Erdungsanlage",[16,389,390],{},"Die Unterlagen müssen den tatsächlichen Zustand wiedergeben. Fehlende oder widersprüchliche Pläne können als Verstoß im Kontrollbericht erscheinen; den offiziellen Befund stellt allein der zugelassene Kontrollorganismus fest.",[11,392,394],{"id":393},"was-muss-auf-den-situationsplan","Was muss auf den Situationsplan?",[118,396,398],{"id":397},"checkliste","Checkliste",[123,400,401,404,407,410,413,416,419,422,429],{},[126,402,403],{},"Lesbarer, vereinfachter Grundriss jeder betroffenen Etage",[126,405,406],{},"Position aller Steckdosen (Einzel, Doppel, mit Erdung)",[126,408,409],{},"Position aller Schalter (Ein\u002FAus, Wechsel, Dimmer)",[126,411,412],{},"Beleuchtungspunkte (Decke, Wand, Außen)",[126,414,415],{},"Verteilerkasten und Zählerposition",[126,417,418],{},"Festanschlussgeräte (Kochfeld, Boiler, Wallbox)",[126,420,421],{},"Eindeutige Lage der im Eindrahtschema genannten Betriebsmittel",[126,423,424,425,428],{},"Stromkreis-Referenznummern (die Nummerierung muss zwischen Situationsplan und Eindrahtschema ",[29,426,427],{},"identisch"," sein)",[126,430,431],{},"Passende Symbole aus AREI\u002FRGIE Tabelle 2.23 (Kapitel 2.13)",[11,433,435],{"id":434},"situationsplan-vs-eindrahtschema","Situationsplan vs. Eindrahtschema",[62,437,438,449],{},[65,439,440],{},[68,441,442,445,447],{},[71,443,444],{},"Eigenschaft",[71,446,26],{},[71,448,297],{},[81,450,451,462,473,483,494,505],{},[68,452,453,456,459],{},[86,454,455],{},"Darstellung",[86,457,458],{},"Physischer Grundriss",[86,460,461],{},"Logisches Schaltbild",[68,463,464,467,470],{},[86,465,466],{},"Zeigt Position?",[86,468,469],{},"Ja — wo genau",[86,471,472],{},"Nein",[68,474,475,478,480],{},[86,476,477],{},"Zeigt Hierarchie?",[86,479,472],{},[86,481,482],{},"Ja — vom Netz bis zum Verbraucher",[68,484,485,488,491],{},[86,486,487],{},"Schutzgeräte",[86,489,490],{},"Nur Position",[86,492,493],{},"Nennwerte, Typ, Koordination",[68,495,496,499,502],{},[86,497,498],{},"Kabelangaben",[86,500,501],{},"Verläufe sichtbar",[86,503,504],{},"Typ und Querschnitt angegeben",[68,506,507,510,513],{},[86,508,509],{},"Maßstab",[86,511,512],{},"Nicht pauschal vorgegeben; lesbar und eindeutig",[86,514,515],{},"Nicht maßstäblich",[16,517,518],{},"Beide Dokumente ergänzen sich und sind gleichermaßen Pflicht.",[11,520,522],{"id":521},"verwandte-artikel","Verwandte Artikel",[123,524,525,531],{},[126,526,527],{},[48,528,530],{"href":529},"\u002Fde\u002Fblog\u002Feindrahtschema-erstellen","Eindrahtschema selbst erstellen — Schritt für Schritt",[126,532,533],{},[48,534,536],{"href":535},"\u002Fde\u002Fblog\u002Felektroplan-kosten","Was kostet ein Elektroplan in Belgien?",[16,538,539],{},[48,540,541],{"href":262},"Erstellen Sie jetzt Ihren Situationsplan mit PlanElec — kostenlos →",{"title":265,"searchDepth":266,"depth":266,"links":543},[544,545,546,549,550],{"id":310,"depth":266,"text":311},{"id":334,"depth":266,"text":335},{"id":393,"depth":266,"text":394,"children":547},[548],{"id":397,"depth":273,"text":398},{"id":434,"depth":266,"text":435},{"id":521,"depth":266,"text":522},"Der Situationsplan zeigt, wo alle elektrischen Komponenten in Ihrem Gebäude physisch installiert sind. Erfahren Sie, was drauf muss und wie er sich vom Eindrahtschema unterscheidet.","de",{},"\u002Fblog\u002Fwhat-is-a-situation-plan.de",{"title":305,"description":551},"was-ist-ein-situationsplan","blog\u002Fwhat-is-a-situation-plan.de",[291,292,26,22,293,294,297,559,295,560,561,562,563],"Eendraadschema","Stromabnahme","Keuring","Grundriss","Belgien","zF0HlnER8EfaDeyGlgElnlbLSqOUhslAS7U9UO0nJnk",{"id":566,"title":567,"articleId":6,"body":568,"category":276,"date":277,"description":814,"extension":279,"lastUpdated":280,"locale":815,"meta":816,"navigation":283,"path":817,"publishDate":277,"readTime":285,"refreshInterval":286,"seo":818,"slug":6,"stem":819,"tags":820,"__hash__":826},"blog\u002Fblog\u002Fwhat-is-a-situation-plan.en.md","What Is a Situation Plan?",{"type":8,"value":569,"toc":805},[570,574,587,594,598,611,651,654,658,662,695,699,779,782,786,800],[11,571,573],{"id":572},"a-floor-plan-of-your-electrical-installation","A floor plan of your electrical installation",[16,575,576,577,579,580,582,583,586],{},"A situation plan (Dutch: ",[20,578,22],{},", French: ",[20,581,293],{},") is a simplified floor plan showing the ",[29,584,585],{},"physical location"," of relevant electrical equipment — such as sockets, switches, lights, distribution boards and fixed appliances. No universal drawing scale is prescribed; clarity and unambiguous locations matter.",[16,588,589,590,593],{},"Unlike a single-line diagram, the situation plan doesn't show the logical circuit hierarchy, but rather ",[29,591,592],{},"exactly where"," everything is located.",[11,595,597],{"id":596},"what-does-the-arei-say","What does the AREI say?",[16,599,600,601,605,606,610],{},"The Federal Public Service Economy's ",[48,602,604],{"href":50,"rel":603},[52],"official domestic-inspection guidance"," lists the single-line diagram and situation plan among the minimum documents to provide. The current ",[48,607,609],{"href":57,"rel":608},[52],"AREI\u002FRGIE Book 1"," defines their content and shared references:",[62,612,613,625],{},[65,614,615],{},[68,616,617,619,622],{},[71,618,73],{},[71,620,621],{},"AREI Article",[71,623,624],{},"Shows",[81,626,627,639],{},[68,628,629,634,636],{},[86,630,631],{},[29,632,633],{},"Single-line diagram",[86,635,93],{},[86,637,638],{},"Logical structure — protection devices, circuits, hierarchy",[68,640,641,646,648],{},[86,642,643],{},[29,644,645],{},"Situation plan",[86,647,106],{},[86,649,650],{},"Physical location — where everything is installed in the building, incl. location of the meter board and earthing system",[16,652,653],{},"The documents must reflect the real installation. Missing or inconsistent plans may be recorded as an infringement; only the approved inspection body determines the official outcome.",[11,655,657],{"id":656},"what-must-be-on-the-situation-plan","What must be on the situation plan?",[118,659,661],{"id":660},"checklist","Checklist",[123,663,664,667,670,673,676,679,682,685,692],{},[126,665,666],{},"Clear, simplified floor plan of each relevant storey",[126,668,669],{},"Position of all sockets (single, double, earthed)",[126,671,672],{},"Position of all switches (on\u002Foff, two-way, dimmer)",[126,674,675],{},"Lighting points (ceiling, wall, outdoor)",[126,677,678],{},"Distribution board and meter location",[126,680,681],{},"Fixed appliances (hob, boiler, EV charger)",[126,683,684],{},"Unambiguous locations for the equipment referenced on the single-line diagram",[126,686,687,688,691],{},"Circuit reference numbers (numbering must be ",[29,689,690],{},"identical"," between situation plan and single-line diagram)",[126,693,694],{},"Appropriate symbols from AREI\u002FRGIE Table 2.23 (Chapter 2.13)",[11,696,698],{"id":697},"situation-plan-vs-single-line-diagram","Situation plan vs. single-line diagram",[62,700,701,712],{},[65,702,703],{},[68,704,705,708,710],{},[71,706,707],{},"Property",[71,709,645],{},[71,711,633],{},[81,713,714,725,736,746,757,768],{},[68,715,716,719,722],{},[86,717,718],{},"Representation",[86,720,721],{},"Physical floor plan",[86,723,724],{},"Logical circuit diagram",[68,726,727,730,733],{},[86,728,729],{},"Shows position?",[86,731,732],{},"Yes — exact location",[86,734,735],{},"No",[68,737,738,741,743],{},[86,739,740],{},"Shows hierarchy?",[86,742,735],{},[86,744,745],{},"Yes — from grid to consumer",[68,747,748,751,754],{},[86,749,750],{},"Protection devices",[86,752,753],{},"Position only",[86,755,756],{},"Ratings, type, coordination",[68,758,759,762,765],{},[86,760,761],{},"Cable info",[86,763,764],{},"Routes visible",[86,766,767],{},"Type and cross-section listed",[68,769,770,773,776],{},[86,771,772],{},"Scaled",[86,774,775],{},"No universal scale; clear and unambiguous",[86,777,778],{},"Not to scale",[16,780,781],{},"Both documents complement each other and are equally mandatory.",[11,783,785],{"id":784},"related-articles","Related articles",[123,787,788,794],{},[126,789,790],{},[48,791,793],{"href":792},"\u002Fen\u002Fblog\u002Fsingle-line-diagram","How to create a single-line diagram — step by step",[126,795,796],{},[48,797,799],{"href":798},"\u002Fen\u002Fblog\u002Felectrical-plan-costs","How much does an electrical plan cost in Belgium?",[16,801,802],{},[48,803,804],{"href":262},"Create your situation plan with PlanElec now — free →",{"title":265,"searchDepth":266,"depth":266,"links":806},[807,808,809,812,813],{"id":572,"depth":266,"text":573},{"id":596,"depth":266,"text":597},{"id":656,"depth":266,"text":657,"children":810},[811],{"id":660,"depth":273,"text":661},{"id":697,"depth":266,"text":698},{"id":784,"depth":266,"text":785},"A situation plan shows where all electrical components are physically installed in your building. Learn what it must include and how it differs from a single-line diagram.","en",{},"\u002Fblog\u002Fwhat-is-a-situation-plan.en",{"title":567,"description":814},"blog\u002Fwhat-is-a-situation-plan.en",[291,292,294,22,26,293,821,296,297,295,822,823,824,825],"single-line diagram","inspection","keuring","floor plan","Belgium","Sl_CbBTNKJDErh1j4L7pwbtQxJMic81QjWr0KyapMbw",{"id":4,"title":5,"articleId":6,"body":828,"category":276,"date":277,"description":278,"extension":279,"lastUpdated":280,"locale":281,"meta":1005,"navigation":283,"path":284,"publishDate":277,"readTime":285,"refreshInterval":286,"seo":1006,"slug":288,"stem":289,"tags":1007,"__hash__":301},{"type":8,"value":829,"toc":996},[830,832,840,844,846,854,888,890,892,894,914,916,978,980,982,992],[11,831,14],{"id":13},[16,833,18,834,23,836,27,838,32],{},[20,835,22],{},[20,837,26],{},[29,839,31],{},[16,841,35,842,39],{},[29,843,38],{},[11,845,43],{"id":42},[16,847,46,848,54,851,60],{},[48,849,53],{"href":50,"rel":850},[52],[48,852,59],{"href":57,"rel":853},[52],[62,855,856,866],{},[65,857,858],{},[68,859,860,862,864],{},[71,861,73],{},[71,863,76],{},[71,865,79],{},[81,867,868,878],{},[68,869,870,874,876],{},[86,871,872],{},[29,873,90],{},[86,875,93],{},[86,877,96],{},[68,879,880,884,886],{},[86,881,882],{},[29,883,103],{},[86,885,106],{},[86,887,109],{},[16,889,112],{},[11,891,116],{"id":115},[118,893,121],{"id":120},[123,895,896,898,900,902,904,906,908,910,912],{},[126,897,128],{},[126,899,131],{},[126,901,134],{},[126,903,137],{},[126,905,140],{},[126,907,143],{},[126,909,146],{},[126,911,149],{},[126,913,152],{},[11,915,156],{"id":155},[62,917,918,928],{},[65,919,920],{},[68,921,922,924,926],{},[71,923,165],{},[71,925,103],{},[71,927,90],{},[81,929,930,938,946,954,962,970],{},[68,931,932,934,936],{},[86,933,176],{},[86,935,179],{},[86,937,182],{},[68,939,940,942,944],{},[86,941,187],{},[86,943,190],{},[86,945,193],{},[68,947,948,950,952],{},[86,949,198],{},[86,951,193],{},[86,953,203],{},[68,955,956,958,960],{},[86,957,208],{},[86,959,211],{},[86,961,214],{},[68,963,964,966,968],{},[86,965,219],{},[86,967,222],{},[86,969,225],{},[68,971,972,974,976],{},[86,973,230],{},[86,975,233],{},[86,977,236],{},[16,979,239],{},[11,981,243],{"id":242},[123,983,984,988],{},[126,985,986],{},[48,987,251],{"href":250},[126,989,990],{},[48,991,257],{"href":256},[16,993,994],{},[48,995,263],{"href":262},{"title":265,"searchDepth":266,"depth":266,"links":997},[998,999,1000,1003,1004],{"id":13,"depth":266,"text":14},{"id":42,"depth":266,"text":43},{"id":115,"depth":266,"text":116,"children":1001},[1002],{"id":120,"depth":273,"text":121},{"id":155,"depth":266,"text":156},{"id":242,"depth":266,"text":243},{},{"title":5,"description":278},[291,292,293,22,26,294,295,296,297,298,299,300],{"id":1009,"title":1010,"articleId":6,"body":1011,"category":276,"date":277,"description":1254,"extension":279,"lastUpdated":280,"locale":1255,"meta":1256,"navigation":283,"path":1257,"publishDate":277,"readTime":285,"refreshInterval":286,"seo":1258,"slug":1259,"stem":1260,"tags":1261,"__hash__":1265},"blog\u002Fblog\u002Fwhat-is-a-situation-plan.nl.md","Wat is een situatieschema?",{"type":8,"value":1012,"toc":1245},[1013,1017,1030,1037,1041,1054,1093,1096,1100,1102,1135,1139,1219,1222,1226,1240],[11,1014,1016],{"id":1015},"een-plattegrond-van-uw-elektrische-installatie","Een plattegrond van uw elektrische installatie",[16,1018,1019,1020,1022,1023,1025,1026,1029],{},"Het situatieschema (Frans: ",[20,1021,293],{},", Duits: ",[20,1024,26],{},") is een vereenvoudigde plattegrond met de ",[29,1027,1028],{},"fysieke positie"," van het relevante elektrische materieel — bijvoorbeeld stopcontacten, schakelaars, lichtpunten, verdeelborden en vaste toestellen. Er geldt geen universele tekenschaal; leesbaarheid en eenduidige locaties zijn doorslaggevend.",[16,1031,1032,1033,1036],{},"In tegenstelling tot het eendraadschema toont het situatieschema niet de logische circuithiërarchie, maar ",[29,1034,1035],{},"waar precies"," alles zich bevindt.",[11,1038,1040],{"id":1039},"wat-zegt-het-arei","Wat zegt het AREI?",[16,1042,1043,1044,1048,1049,1053],{},"De ",[48,1045,1047],{"href":50,"rel":1046},[52],"officiële FOD-pagina over huishoudelijke controles"," noemt het eendraadschema en situatieschema als minimaal voor te leggen documenten. Het actuele ",[48,1050,1052],{"href":57,"rel":1051},[52],"AREI\u002FRGIE Boek 1"," beschrijft de inhoud en gezamenlijke verwijzingen:",[62,1055,1056,1068],{},[65,1057,1058],{},[68,1059,1060,1062,1065],{},[71,1061,73],{},[71,1063,1064],{},"AREI-artikel",[71,1066,1067],{},"Toont",[81,1069,1070,1081],{},[68,1071,1072,1076,1078],{},[86,1073,1074],{},[29,1075,559],{},[86,1077,93],{},[86,1079,1080],{},"Logische structuur — beschermingstoestellen, kringen, hiërarchie",[68,1082,1083,1088,1090],{},[86,1084,1085],{},[29,1086,1087],{},"Situatieschema",[86,1089,106],{},[86,1091,1092],{},"Fysieke positie — waar alles in het gebouw is geïnstalleerd, incl. locatie van de meterkast en aardingsinstallatie",[16,1094,1095],{},"De documenten moeten met de werkelijke installatie overeenstemmen. Ontbrekende of tegenstrijdige plannen kunnen als inbreuk in het verslag komen; alleen het erkende keuringsorganisme bepaalt de officiële conclusie.",[11,1097,1099],{"id":1098},"wat-moet-op-het-situatieschema-staan","Wat moet op het situatieschema staan?",[118,1101,661],{"id":660},[123,1103,1104,1107,1110,1113,1116,1119,1122,1125,1132],{},[126,1105,1106],{},"Duidelijke, vereenvoudigde plattegrond van elke betrokken verdieping",[126,1108,1109],{},"Positie van alle stopcontacten (enkel, dubbel, geaard)",[126,1111,1112],{},"Positie van alle schakelaars (aan\u002Fuit, wissel, dimmer)",[126,1114,1115],{},"Verlichtingspunten (plafond, wand, buiten)",[126,1117,1118],{},"Verdeelbord en meterpositie",[126,1120,1121],{},"Vast aangesloten toestellen (kookplaat, boiler, laadpaal)",[126,1123,1124],{},"Eenduidige locaties van het materieel waarnaar het eendraadschema verwijst",[126,1126,1127,1128,1131],{},"Kringreferentienummers (de nummering moet tussen situatieschema en eendraadschema ",[29,1129,1130],{},"identiek"," zijn)",[126,1133,1134],{},"Passende symbolen uit AREI\u002FRGIE-tabel 2.23 (hoofdstuk 2.13)",[11,1136,1138],{"id":1137},"situatieschema-vs-eendraadschema","Situatieschema vs. eendraadschema",[62,1140,1141,1152],{},[65,1142,1143],{},[68,1144,1145,1148,1150],{},[71,1146,1147],{},"Eigenschap",[71,1149,1087],{},[71,1151,559],{},[81,1153,1154,1165,1176,1186,1197,1208],{},[68,1155,1156,1159,1162],{},[86,1157,1158],{},"Weergave",[86,1160,1161],{},"Fysieke plattegrond",[86,1163,1164],{},"Logisch schakelschema",[68,1166,1167,1170,1173],{},[86,1168,1169],{},"Toont positie?",[86,1171,1172],{},"Ja — exacte locatie",[86,1174,1175],{},"Nee",[68,1177,1178,1181,1183],{},[86,1179,1180],{},"Toont hiërarchie?",[86,1182,1175],{},[86,1184,1185],{},"Ja — van net tot verbruiker",[68,1187,1188,1191,1194],{},[86,1189,1190],{},"Beschermingstoestellen",[86,1192,1193],{},"Alleen positie",[86,1195,1196],{},"Waarden, type, coördinatie",[68,1198,1199,1202,1205],{},[86,1200,1201],{},"Kabelinfo",[86,1203,1204],{},"Routes zichtbaar",[86,1206,1207],{},"Type en doorsnede vermeld",[68,1209,1210,1213,1216],{},[86,1211,1212],{},"Op schaal",[86,1214,1215],{},"Geen universele schaal; duidelijk en eenduidig",[86,1217,1218],{},"Niet op schaal",[16,1220,1221],{},"Beide documenten vullen elkaar aan en zijn beide verplicht.",[11,1223,1225],{"id":1224},"gerelateerde-artikelen","Gerelateerde artikelen",[123,1227,1228,1234],{},[126,1229,1230],{},[48,1231,1233],{"href":1232},"\u002Fblog\u002Feendraadschema-maken","Eendraadschema zelf maken — stap voor stap",[126,1235,1236],{},[48,1237,1239],{"href":1238},"\u002Fblog\u002Fkosten-elektriciteitsplan","Wat kost een elektroplan in België?",[16,1241,1242],{},[48,1243,1244],{"href":262},"Maak nu uw situatieschema met PlanElec — gratis →",{"title":265,"searchDepth":266,"depth":266,"links":1246},[1247,1248,1249,1252,1253],{"id":1015,"depth":266,"text":1016},{"id":1039,"depth":266,"text":1040},{"id":1098,"depth":266,"text":1099,"children":1250},[1251],{"id":660,"depth":273,"text":661},{"id":1137,"depth":266,"text":1138},{"id":1224,"depth":266,"text":1225},"Het situatieschema toont waar alle elektrische componenten fysiek in uw gebouw zijn geïnstalleerd. Ontdek wat erop moet staan en hoe het verschilt van een eendraadschema.","nl",{},"\u002Fblog\u002Fwhat-is-a-situation-plan.nl",{"title":1010,"description":1254},"wat-is-een-situatieschema","blog\u002Fwhat-is-a-situation-plan.nl",[291,292,22,1262,293,26,294,296,297,295,823,1263,1264],"situatieplan","plattegrond","België","r54HTwjraF1ziwZwDOVYpCsF3_vt6HiqucwSFQ_KwsE",1788389260722]