[{"data":1,"prerenderedAt":4179},["ShallowReactive",2],{"blog-post-fr-dessiner-plan-situation-guide":3,"blog-alternates-draw-situation-plan":926},{"id":4,"title":5,"articleId":6,"body":7,"category":905,"date":906,"description":907,"extension":908,"lastUpdated":909,"locale":910,"meta":911,"navigation":741,"path":912,"publishDate":906,"readTime":913,"refreshInterval":914,"seo":915,"slug":916,"stem":917,"tags":918,"__hash__":925},"blog\u002Fblog\u002Fdraw-situation-plan.fr.md","Dessiner un plan de situation : Guide étape par étape selon le RGIE","draw-situation-plan",{"type":8,"value":9,"toc":880},"minimark",[10,19,37,40,43,48,53,56,61,86,90,93,203,205,209,216,395,403,405,409,412,416,449,453,473,477,494,498,501,505,525,527,531,538,543,555,560,574,591,593,597,600,626,628,632,724,726,730,798,802,805,808,811,815,818,821,825,839,841,845,865,867],[11,12,13,14,18],"p",{},"Le plan de situation (aussi appelé schéma de position) montre ",[15,16,17],"strong",{},"où exactement"," chaque composant électrique se trouve dans votre bâtiment. Pour une nouvelle installation domestique ou une modification ou extension importante, il est établi avec le schéma unifilaire. Les installations existantes et petits changements suivent des règles précises ; l'organisme agréé examine le dossier concret.",[20,21,22],"blockquote",{},[11,23,24,27,28,32,33,36],{},[15,25,26],{},"En bref :"," Tandis que le schéma unifilaire représente le ",[29,30,31],"em",{},"raccordement logique"," (quel interrupteur commande quel luminaire, via quel circuit), le plan de situation montre la ",[29,34,35],{},"position physique"," de chaque composant sur le plan d'étage.",[11,38,39],{},"Ce guide explique comment préparer un plan de situation vérifiable, étape par étape. Seul un organisme agréé peut conclure à la conformité du dossier complet et de l'installation réalisée.",[41,42],"hr",{},[44,45,47],"h2",{"id":46},"étape-1-préparer-le-plan-détage","Étape 1 : Préparer le plan d'étage",[49,50,52],"h3",{"id":51},"dimensions-et-échelle","Dimensions et échelle",[11,54,55],{},"Le plan d'étage constitue la base de votre plan de situation. Vous pouvez le reprendre d'un plan de construction ou le dessiner vous-même.",[11,57,58],{},[15,59,60],{},"Important :",[62,63,64,72,79],"ul",{},[65,66,67,68,71],"li",{},"Utilisez une ",[15,69,70],{},"échelle uniforme"," (courante : 1:50 ou 1:100).",[65,73,74,75,78],{},"Dessinez tous les ",[15,76,77],{},"murs, portes et fenêtres",".",[65,80,81,82,85],{},"Marquez le ",[15,83,84],{},"sens d'ouverture"," des portes (quart de cercle) — cela influence la position des interrupteurs.",[49,87,89],{"id":88},"étiqueter-les-pièces","Étiqueter les pièces",[11,91,92],{},"Identifiez chaque pièce avec sa désignation et idéalement sa surface :",[94,95,96,112],"table",{},[97,98,99],"thead",{},[100,101,102,106,109],"tr",{},[103,104,105],"th",{},"Abréviation",[103,107,108],{},"Pièce",[103,110,111],{},"Surface typique",[113,114,115,127,138,149,160,171,182,193],"tbody",{},[100,116,117,121,124],{},[118,119,120],"td",{},"SÉJ",[118,122,123],{},"Séjour",[118,125,126],{},"25–40 m²",[100,128,129,132,135],{},[118,130,131],{},"CUI",[118,133,134],{},"Cuisine",[118,136,137],{},"10–20 m²",[100,139,140,143,146],{},[118,141,142],{},"CH",[118,144,145],{},"Chambre",[118,147,148],{},"12–18 m²",[100,150,151,154,157],{},[118,152,153],{},"SDB",[118,155,156],{},"Salle de bain",[118,158,159],{},"5–10 m²",[100,161,162,165,168],{},[118,163,164],{},"COU",[118,166,167],{},"Couloir",[118,169,170],{},"5–15 m²",[100,172,173,176,179],{},[118,174,175],{},"GAR",[118,177,178],{},"Garage",[118,180,181],{},"15–30 m²",[100,183,184,187,190],{},[118,185,186],{},"CAV",[118,188,189],{},"Cave",[118,191,192],{},"variable",[100,194,195,198,201],{},[118,196,197],{},"EXT",[118,199,200],{},"Extérieur",[118,202,192],{},[41,204],{},[44,206,208],{"id":207},"étape-2-utiliser-les-symboles-rgie","Étape 2 : Utiliser les symboles RGIE",[11,210,211,212,215],{},"Le ",[15,213,214],{},"tableau 2.23"," du RGIE donne une liste non exhaustive de symboles. Si aucun symbole n'est repris pour un composant, un autre signe clairement identifiable peut être utilisé s'il est défini dans la légende. Voici dix groupes utiles pour le plan de situation :",[94,217,218,234],{},[97,219,220],{},[100,221,222,225,228,231],{},[103,223,224],{},"N°",[103,226,227],{},"Symbole",[103,229,230],{},"Description",[103,232,233],{},"Utilisation",[113,235,236,252,267,283,299,315,331,347,363,379],{},[100,237,238,241,244,249],{},[118,239,240],{},"1",[118,242,243],{},"⏚ Demi-cercle",[118,245,246],{},[15,247,248],{},"Prise simple",[118,250,251],{},"Marquer position murale",[100,253,254,257,260,265],{},[118,255,256],{},"2",[118,258,259],{},"⏚⏚ Double demi-cercle",[118,261,262],{},[15,263,264],{},"Prise double",[118,266,251],{},[100,268,269,272,275,280],{},[118,270,271],{},"3",[118,273,274],{},"○ avec croix",[118,276,277],{},[15,278,279],{},"Plafonnier",[118,281,282],{},"Centre de la pièce\u002Fposition",[100,284,285,288,291,296],{},[118,286,287],{},"4",[118,289,290],{},"─○ avec trait",[118,292,293],{},[15,294,295],{},"Applique murale",[118,297,298],{},"Sur le mur",[100,300,301,304,307,312],{},[118,302,303],{},"5",[118,305,306],{},"Symbole interrupteur",[118,308,309],{},[15,310,311],{},"Interrupteur unipolaire",[118,313,314],{},"À côté de la porte (côté ouverture)",[100,316,317,320,323,328],{},[118,318,319],{},"6",[118,321,322],{},"Symbole interrupteur 2 flèches",[118,324,325],{},[15,326,327],{},"Interrupteur sériel",[118,329,330],{},"Commande 2 luminaires",[100,332,333,336,339,344],{},[118,334,335],{},"7",[118,337,338],{},"Symbole interrupteur avec ligne",[118,340,341],{},[15,342,343],{},"Interrupteur va-et-vient",[118,345,346],{},"Deux points, un luminaire",[100,348,349,352,355,360],{},[118,350,351],{},"8",[118,353,354],{},"Rectangle avec éclair",[118,356,357],{},[15,358,359],{},"Tableau de distribution",[118,361,362],{},"Généralement couloir\u002Flocal technique",[100,364,365,368,371,376],{},[118,366,367],{},"9",[118,369,370],{},"⏚ avec PE",[118,372,373],{},[15,374,375],{},"Prise de terre",[118,377,378],{},"Point de mise à la terre",[100,380,381,384,387,392],{},[118,382,383],{},"10",[118,385,386],{},"Cercle avec R",[118,388,389],{},[15,390,391],{},"Détecteur de fumée",[118,393,394],{},"Chaque chambre, couloir, cage d'escalier",[20,396,397],{},[11,398,399,402],{},[15,400,401],{},"Conseil :"," Utilisez les symboles RGIE du Tableau 2.23 pour les composants courants. Si des symboles différents sont nécessaires, ils doivent être clairement identifiables et expliqués dans la légende — les symboles non définis ou non expliqués seront refusés lors du contrôle.",[41,404],{},[44,406,408],{"id":407},"étape-3-dessiner-les-composants","Étape 3 : Dessiner les composants",[11,410,411],{},"Placez maintenant les symboles sur le plan d'étage. Les règles suivantes aident au positionnement correct :",[49,413,415],{"id":414},"prises-de-courant","Prises de courant",[62,417,418,425,431,437,443],{},[65,419,420,421,424],{},"Dessiner ",[15,422,423],{},"sur le mur",", à la position réelle.",[65,426,427,430],{},[15,428,429],{},"Cuisine :"," Relever séparément les prises de travail et appareils fixes réels ; quantité et circuits dédiés découlent de l'usage et de l'étude professionnelle.",[65,432,433,436],{},[15,434,435],{},"Pièces de vie :"," Dessiner les prises prévues ou existantes ; le RGIE ne fixe aucun nombre général par surface.",[65,438,439,442],{},[15,440,441],{},"Salle de bain :"," Prises basse tension à partir de la zone 2 (uniquement pour les baignoires ; la prise doit être protégée par un dispositif différentiel à très haute sensibilité ≤ 10 mA, ou individuellement par un transformateur de séparation d'une puissance maximale de 100 W) ou hors zones. Pour les douches, la zone 2 n'existe pas (art. 7.1.3.2 n° 3b, art. 7.1.5.2d).",[65,444,445,448],{},[15,446,447],{},"Extérieur :"," Déterminer professionnellement les influences externes, l'indice IP requis et la protection 30 mA applicable ; un différentiel dédié n'est pas une conclusion générale du plan.",[49,450,452],{"id":451},"interrupteurs","Interrupteurs",[62,454,455,461,467],{},[65,456,457,460],{},[15,458,459],{},"À côté de la porte"," du côté de l'ouverture, à environ 105 cm de hauteur (recommandation pratique — le RGIE ne prescrit pas de hauteur spécifique pour les interrupteurs, mais exige qu'ils soient « facilement accessibles »).",[65,462,463,466],{},[15,464,465],{},"Interrupteurs va-et-vient"," pour les pièces à plusieurs entrées ou en début\u002Ffin d'escalier.",[65,468,469,470,78],{},"Reliez les interrupteurs et les luminaires associés par une ",[15,471,472],{},"ligne pointillée",[49,474,476],{"id":475},"points-lumineux","Points lumineux",[62,478,479,485,491],{},[65,480,481,484],{},[15,482,483],{},"Plafonniers"," au centre de la pièce ou à la position prévue.",[65,486,487,490],{},[15,488,489],{},"Appliques murales"," à la position sur le mur.",[65,492,493],{},"Dessiner tous les points lumineux réellement prévus ou présents ; leur nombre relève de l'usage et de l'étude.",[49,495,497],{"id":496},"informations-régionales-de-sécurité-incendie","Informations régionales de sécurité incendie",[11,499,500],{},"Les détecteurs peuvent être ajoutés dans une couche bâtiment distincte. Les exigences varient selon la région et l'usage et se vérifient auprès de la source officielle compétente actuelle. Elles ne constituent pas une mention générale du plan RGIE et restent séparées des références électriques.",[49,502,504],{"id":503},"consommateurs-spéciaux","Consommateurs spéciaux",[62,506,507,513,519],{},[65,508,509,512],{},[15,510,511],{},"Borne de recharge"," (véhicule électrique) : garage ou mur extérieur, circuit dédié.",[65,514,515,518],{},[15,516,517],{},"Chauffe-eau\u002FBoiler :"," Circuit dédié, dessiner la position.",[65,520,521,524],{},[15,522,523],{},"Pompe à chaleur\u002FClimatisation :"," Marquer unité extérieure + unité intérieure.",[41,526],{},[44,528,530],{"id":529},"étape-4-attribuer-les-numéros-de-circuits","Étape 4 : Attribuer les numéros de circuits",[11,532,533,534,537],{},"Chaque composant du plan de situation reçoit le ",[15,535,536],{},"même numéro de circuit"," que dans le schéma unifilaire. C'est essentiel pour l'attribution lors du contrôle.",[11,539,540],{},[15,541,542],{},"Comment ça marche :",[544,545,546,549,552],"ol",{},[65,547,548],{},"Le RGIE identifie les circuits élémentaires par une lettre majuscule (A, B, C, ...) et les éléments individuels (point lumineux, prise) par un numéro d'ordre — par ex. « A1, A2, ... ».",[65,550,551],{},"Inscrivez cet identifiant à côté de chaque composant sur le plan de situation.",[65,553,554],{},"Une numérotation simplifiée (par ex. « C1 » ou « 1 ») est courante en pratique, pour autant que le schéma unifilaire et le plan de situation restent cohérents.",[11,556,557],{},[15,558,559],{},"Exemple :",[62,561,562,565,568,571],{},[65,563,564],{},"Circuit 1 : Éclairage rez-de-chaussée → Tous les luminaires du RDC reçoivent « 1 ».",[65,566,567],{},"Circuit 2 : Prises séjour → Toutes les prises du séjour reçoivent « 2 ».",[65,569,570],{},"Circuit 3 : Prises cuisine → Toutes les prises de cuisine reçoivent « 3 ».",[65,572,573],{},"Circuit 4 : Dédié four → Une prise avec « 4 ».",[20,575,576,585],{},[11,577,578,580,581,584],{},[15,579,60],{}," Les numéros doivent correspondre ",[15,582,583],{},"exactement"," entre le schéma unifilaire et le plan de situation. Les incohérences sont l'une des causes les plus fréquentes de remarques lors du contrôle.",[11,586,587,590],{},[15,588,589],{},"Obligation de documentation :"," Art. 9.1.2 n° 1 (schéma unifilaire) et art. 9.1.2 n° 2 (plan de situation).",[41,592],{},[44,594,596],{"id":595},"étape-5-légende-et-étiquetage","Étape 5 : Légende et étiquetage",[11,598,599],{},"Complétez votre plan avec :",[62,601,602,608,614,620],{},[65,603,604,607],{},[15,605,606],{},"Légende"," avec tous les symboles utilisés et leur signification.",[65,609,610,613],{},[15,611,612],{},"Cartouche"," avec : nom du propriétaire, adresse, date, auteur du plan, échelle.",[65,615,616,619],{},[15,617,618],{},"Flèche nord"," (optionnel, mais utile).",[65,621,622,625],{},[15,623,624],{},"Indication d'étage"," pour les bâtiments à plusieurs niveaux (un plan par étage).",[41,627],{},[44,629,631],{"id":630},"erreurs-fréquentes","Erreurs fréquentes",[94,633,634,647],{},[97,635,636],{},[100,637,638,641,644],{},[103,639,640],{},"Erreur",[103,642,643],{},"Conséquence",[103,645,646],{},"Solution",[113,648,649,660,671,682,692,703,714],{},[100,650,651,654,657],{},[118,652,653],{},"Présenter les règles incendie régionales comme règle RGIE",[118,655,656],{},"Mauvaise base de contrôle",[118,658,659],{},"Vérifier séparément la source régionale actuelle et identifier la couche",[100,661,662,665,668],{},[118,663,664],{},"Traiter toutes les prises extérieures pareil",[118,666,667],{},"Influences ou protection potentiellement erronées",[118,669,670],{},"Étudier indice IP et protection 30 mA pour le projet",[100,672,673,676,679],{},[118,674,675],{},"Étiquetage \u002F numéros de circuits manquants",[118,677,678],{},"Remarque",[118,680,681],{},"Numéroter chaque composant",[100,683,684,687,689],{},[118,685,686],{},"Symboles non définis\u002Fnon expliqués",[118,688,678],{},[118,690,691],{},"Utiliser les symboles RGIE (Tableau 2.23) ; choisir des symboles différents de façon claire et les expliquer dans la légende",[100,693,694,697,700],{},[118,695,696],{},"Interrupteur du mauvais côté de la porte",[118,698,699],{},"Non pratique (pas d'infraction RGIE)",[118,701,702],{},"Vérifier le sens d'ouverture",[100,704,705,708,711],{},[118,706,707],{},"Prise de salle de bains représentée dans une zone erronée",[118,709,710],{},"Le plan et l'exécution peuvent produire un constat de sécurité",[118,712,713],{},"Vérifier professionnellement zones et protections selon le chapitre 7.1 actuel",[100,715,716,719,721],{},[118,717,718],{},"Pas de légende",[118,720,678],{},[118,722,723],{},"Joindre un tableau de symboles",[41,725],{},[44,727,729],{"id":728},"checklist-avant-soumission","Checklist avant soumission",[62,731,734,744,750,756,762,768,774,780,786,792],{"className":732},[733],"contains-task-list",[65,735,738,743],{"className":736},[737],"task-list-item",[739,740],"input",{"disabled":741,"type":742},true,"checkbox"," Toutes les pièces étiquetées",[65,745,747,749],{"className":746},[737],[739,748],{"disabled":741,"type":742}," Toutes les prises, interrupteurs, luminaires dessinés",[65,751,753,755],{"className":752},[737],[739,754],{"disabled":741,"type":742}," Informations incendie régionales, si affichées, vérifiées et identifiées séparément",[65,757,759,761],{"className":758},[737],[739,760],{"disabled":741,"type":742}," Prises extérieures relevées avec étude IP et protection propre au projet",[65,763,765,767],{"className":764},[737],[739,766],{"disabled":741,"type":742}," Numéros de circuits sur chaque composant",[65,769,771,773],{"className":770},[737],[739,772],{"disabled":741,"type":742}," Les numéros correspondent au schéma unifilaire",[65,775,777,779],{"className":776},[737],[739,778],{"disabled":741,"type":742}," Symboles RGIE utilisés (Tableau 2.23)",[65,781,783,785],{"className":782},[737],[739,784],{"disabled":741,"type":742}," Légende présente",[65,787,789,791],{"className":788},[737],[739,790],{"disabled":741,"type":742}," Cartouche avec nom, adresse, date",[65,793,795,797],{"className":794},[737],[739,796],{"disabled":741,"type":742}," Un plan par étage",[44,799,801],{"id":800},"faire-la-visite-de-concordance-sur-place","Faire la visite de concordance sur place",[11,803,804],{},"Parcourez le bâtiment avec le projet imprimé ou affiché. Partez du tableau et suivez chaque circuit. Ne vérifiez pas seulement la présence d'une prise : distinguez prise multiple, prise commandée, boîte de connexion, raccordement fixe et point lumineux. La référence d'un interrupteur doit permettre d'identifier le luminaire ou l'appareil commandé. Les équipements cachés par un meuble, les points extérieurs, les locaux techniques et les dépendances sont souvent oubliés.",[11,806,807],{},"Comparez ensuite le schéma unifilaire. Un élément A3 sur le plan de situation doit correspondre au même A3 du circuit A. Les doublons, numéros sautés et appareils déplacés après le relevé créent des dossiers contradictoires. Pour plusieurs niveaux ou bâtiments, adoptez une structure de feuilles explicite et conservez numéro, version et date de version sur chaque document diffusé.",[11,809,810],{},"Le plan décrit l'état réel et non le seul projet initial. Ne clôturez une modification qu'après vérification de la position et du parcours concernés. Pour une modification domestique non importante, le Livre 1 peut accepter une description succincte à la place d'un nouveau schéma unifilaire ; la modification ou l'extension reste à reporter sur le plan de situation. Une modification ou extension importante exige des plans actualisés et le contrôle des travaux concernés avant mise en usage.",[44,812,814],{"id":813},"ce-quun-symbole-ne-démontre-pas","Ce qu'un symbole ne démontre pas",[11,816,817],{},"Un symbole n'atteste ni hauteur de pose, ni indice de protection, ni respect des volumes de salle de bains, ni qualité de terre, ni temps de coupure. Il faut une visite, des mesures et parfois les documents du fabricant. Les obligations de détecteurs de fumée relèvent aussi des règles régionales de construction et de logement ; elles ne doivent pas être transformées en exigence générale du plan RGIE.",[11,819,820],{},"PlanElec relie position et affectation électrique dans le même projet, mais chaque proposition doit être contrôlée. Un équipement non placé, sans circuit ou présent uniquement sur une image de référence ne peut pas être considéré comme achevé. L'auto-contrôle est indicatif et limité aux règles prises en charge. L'évaluation officielle appartient à l'organisme agréé.",[44,822,824],{"id":823},"source-officielle","Source officielle",[62,826,827,836],{},[65,828,829],{},[830,831,835],"a",{"href":832,"rel":833},"https:\u002F\u002Feconomie.fgov.be\u002Ffr\u002Fpublications\u002Freglement-general-sur-les",[834],"nofollow","SPF Économie : RGIE, Livre 1 dans sa version officielle actuelle",[65,837,838],{},"La section 3.1.2 et le tableau 2.23 constituent la base. Si le tableau ne prévoit aucun symbole, un signe non ambigu défini dans la légende peut être employé.",[41,840],{},[44,842,844],{"id":843},"articles-connexes","Articles connexes",[62,846,847,853,859],{},[65,848,849],{},[830,850,852],{"href":851},"\u002Ffr\u002Fblog\u002Fschema-unifilaire","Créer un schéma unifilaire en Belgique",[65,854,855],{},[830,856,858],{"href":857},"\u002Ffr\u002Fblog\u002Fcontrole-electrique","Contrôle électrique en Belgique",[65,860,861],{},[830,862,864],{"href":863},"\u002Ffr\u002Fblog\u002Fplanifier-tableau-electrique","Planifier un tableau électrique : Conception et dimensionnement",[41,866],{},[11,868,869],{},[29,870,871,872,875,876],{},"Avec ",[15,873,874],{},"PlanElec",", créez votre plan de situation directement à partir du plan d'étage — dessinez les pièces, placez les appareils par glisser-déposer, les symboles RGIE sont utilisés automatiquement. ",[830,877,879],{"href":878},"\u002F","Essayer gratuitement →",{"title":881,"searchDepth":882,"depth":882,"links":883},"",2,[884,889,890,897,898,899,900,901,902,903,904],{"id":46,"depth":882,"text":47,"children":885},[886,888],{"id":51,"depth":887,"text":52},3,{"id":88,"depth":887,"text":89},{"id":207,"depth":882,"text":208},{"id":407,"depth":882,"text":408,"children":891},[892,893,894,895,896],{"id":414,"depth":887,"text":415},{"id":451,"depth":887,"text":452},{"id":475,"depth":887,"text":476},{"id":496,"depth":887,"text":497},{"id":503,"depth":887,"text":504},{"id":529,"depth":882,"text":530},{"id":595,"depth":882,"text":596},{"id":630,"depth":882,"text":631},{"id":728,"depth":882,"text":729},{"id":800,"depth":882,"text":801},{"id":813,"depth":882,"text":814},{"id":823,"depth":882,"text":824},{"id":843,"depth":882,"text":844},"guide","2026-03-30","Guide complet pour préparer un plan de situation vérifiable : plan d'étage, symboles RGIE, références de circuits et contrôle professionnel.","md","2026-08-29","fr",{},"\u002Fblog\u002Fdraw-situation-plan.fr","12 min",12,{"title":5,"description":907},"dessiner-plan-situation-guide","blog\u002Fdraw-situation-plan.fr",[919,920,921,905,922,923,924],"plan de situation","RGIE","symboles","dessin","plan électrique","plan d'étage","0DsnGLD1kt8JxB2vtO-3DC_dtbOB7BM1DKJOaH5m2zA",[927,1806,2668,3304],{"id":928,"title":929,"articleId":6,"body":930,"category":905,"date":906,"description":1790,"extension":908,"lastUpdated":909,"locale":1791,"meta":1792,"navigation":741,"path":1793,"publishDate":906,"readTime":913,"refreshInterval":914,"seo":1794,"slug":1795,"stem":1796,"tags":1797,"__hash__":1805},"blog\u002Fblog\u002Fdraw-situation-plan.de.md","Situationsplan zeichnen: Schritt-für-Schritt-Anleitung nach AREI",{"type":8,"value":931,"toc":1766},[932,939,955,958,960,964,968,971,976,999,1003,1006,1103,1105,1109,1116,1285,1293,1295,1299,1302,1306,1337,1341,1360,1364,1381,1385,1388,1392,1412,1414,1418,1425,1430,1441,1446,1460,1477,1479,1483,1486,1512,1514,1518,1610,1612,1616,1679,1683,1686,1689,1692,1696,1699,1702,1706,1710,1713,1716,1727,1729,1733,1753,1755],[11,933,934,935,938],{},"Der Situationsplan (auch Lageplan oder Plan de Situation) zeigt, ",[15,936,937],{},"wo genau"," sich jede elektrische Komponente in Ihrem Gebäude befindet. Bei neuen hauswirtschaftlichen Anlagen und wesentlichen Änderungen oder Erweiterungen gehört er zusammen mit dem Eindrahtschema zu den vorgeschriebenen Plänen. Für Bestands- und Kleinänderungsfälle gelten genau abgegrenzte Regeln; der Kontrollorganismus beurteilt das konkrete Dossier.",[20,940,941],{},[11,942,943,946,947,950,951,954],{},[15,944,945],{},"Kurz erklärt:"," Während das Eindrahtschema die ",[29,948,949],{},"logische Verschaltung"," darstellt (welcher Schalter steuert welche Leuchte, über welchen Stromkreis), zeigt der Situationsplan die ",[29,952,953],{},"physische Position"," jeder Komponente im Grundriss.",[11,956,957],{},"In dieser Anleitung lernen Sie, wie Sie einen prüfbaren Situationsplan Schritt für Schritt vorbereiten. Ob das gesamte Dossier und die ausgeführte Anlage den Vorschriften entsprechen, beurteilt ausschließlich ein zugelassener Kontrollorganismus.",[41,959],{},[44,961,963],{"id":962},"schritt-1-grundriss-vorbereiten","Schritt 1: Grundriss vorbereiten",[49,965,967],{"id":966},"maße-und-maßstab","Maße und Maßstab",[11,969,970],{},"Der Grundriss bildet die Basis Ihres Situationsplans. Sie können ihn aus einem Bauplan übernehmen oder selbst zeichnen.",[11,972,973],{},[15,974,975],{},"Wichtig:",[62,977,978,985,992],{},[65,979,980,981,984],{},"Verwenden Sie einen ",[15,982,983],{},"einheitlichen Maßstab"," (üblich: 1:50 oder 1:100).",[65,986,987,988,991],{},"Zeichnen Sie alle ",[15,989,990],{},"Wände, Türen und Fenster"," ein.",[65,993,994,995,998],{},"Markieren Sie ",[15,996,997],{},"Öffnungsrichtungen"," von Türen (Viertelkreis) — das beeinflusst die Schalterposition.",[49,1000,1002],{"id":1001},"räume-beschriften","Räume beschriften",[11,1004,1005],{},"Versehen Sie jeden Raum mit seiner Bezeichnung und idealerweise der Fläche:",[94,1007,1008,1021],{},[97,1009,1010],{},[100,1011,1012,1015,1018],{},[103,1013,1014],{},"Kürzel",[103,1016,1017],{},"Raum",[103,1019,1020],{},"Typische Fläche",[113,1022,1023,1033,1043,1053,1063,1073,1082,1093],{},[100,1024,1025,1028,1031],{},[118,1026,1027],{},"WZ",[118,1029,1030],{},"Wohnzimmer",[118,1032,126],{},[100,1034,1035,1038,1041],{},[118,1036,1037],{},"KÜ",[118,1039,1040],{},"Küche",[118,1042,137],{},[100,1044,1045,1048,1051],{},[118,1046,1047],{},"SZ",[118,1049,1050],{},"Schlafzimmer",[118,1052,148],{},[100,1054,1055,1058,1061],{},[118,1056,1057],{},"BZ",[118,1059,1060],{},"Badezimmer",[118,1062,159],{},[100,1064,1065,1068,1071],{},[118,1066,1067],{},"FL",[118,1069,1070],{},"Flur",[118,1072,170],{},[100,1074,1075,1078,1080],{},[118,1076,1077],{},"GA",[118,1079,178],{},[118,1081,181],{},[100,1083,1084,1087,1090],{},[118,1085,1086],{},"KE",[118,1088,1089],{},"Keller",[118,1091,1092],{},"variabel",[100,1094,1095,1098,1101],{},[118,1096,1097],{},"AU",[118,1099,1100],{},"Außenbereich",[118,1102,1092],{},[41,1104],{},[44,1106,1108],{"id":1107},"schritt-2-arei-symbole-verwenden","Schritt 2: AREI-Symbole verwenden",[11,1110,1111,1112,1115],{},"Das AREI gibt in ",[15,1113,1114],{},"Tabelle 2.23"," eine nicht erschöpfende Liste der zu verwendenden Symbole vor. Ist für ein Bauteil kein Symbol in der Tabelle enthalten, darf ein anderes eindeutig identifizierbares Symbol verwendet werden, sofern es in der Legende definiert ist. Hier sind zehn wichtige Symbolgruppen für den Situationsplan:",[94,1117,1118,1134],{},[97,1119,1120],{},[100,1121,1122,1125,1128,1131],{},[103,1123,1124],{},"Nr.",[103,1126,1127],{},"Symbol",[103,1129,1130],{},"Beschreibung",[103,1132,1133],{},"Verwendung",[113,1135,1136,1151,1165,1180,1195,1210,1225,1240,1255,1270],{},[100,1137,1138,1140,1143,1148],{},[118,1139,240],{},[118,1141,1142],{},"⏚ Halbkreis",[118,1144,1145],{},[15,1146,1147],{},"Einfache Steckdose",[118,1149,1150],{},"Wandposition markieren",[100,1152,1153,1155,1158,1163],{},[118,1154,256],{},[118,1156,1157],{},"⏚⏚ Doppel-Halbkreis",[118,1159,1160],{},[15,1161,1162],{},"Doppelsteckdose",[118,1164,1150],{},[100,1166,1167,1169,1172,1177],{},[118,1168,271],{},[118,1170,1171],{},"○ mit Kreuz",[118,1173,1174],{},[15,1175,1176],{},"Deckenleuchte",[118,1178,1179],{},"Mitte des Raums\u002FPosition",[100,1181,1182,1184,1187,1192],{},[118,1183,287],{},[118,1185,1186],{},"─○ mit Strich",[118,1188,1189],{},[15,1190,1191],{},"Wandleuchte",[118,1193,1194],{},"An der Wand",[100,1196,1197,1199,1202,1207],{},[118,1198,303],{},[118,1200,1201],{},"Schaltzeichen",[118,1203,1204],{},[15,1205,1206],{},"Einfacher Schalter",[118,1208,1209],{},"Neben der Tür (Öffnungsseite)",[100,1211,1212,1214,1217,1222],{},[118,1213,319],{},[118,1215,1216],{},"Schaltzeichen mit 2 Pfeilen",[118,1218,1219],{},[15,1220,1221],{},"Serienschalter",[118,1223,1224],{},"Steuert 2 Leuchten",[100,1226,1227,1229,1232,1237],{},[118,1228,335],{},[118,1230,1231],{},"Schaltzeichen mit Linie",[118,1233,1234],{},[15,1235,1236],{},"Wechselschalter",[118,1238,1239],{},"Zwei Stellen, ein Licht",[100,1241,1242,1244,1247,1252],{},[118,1243,351],{},[118,1245,1246],{},"Rechteck mit Blitz",[118,1248,1249],{},[15,1250,1251],{},"Verteilerkasten",[118,1253,1254],{},"Meist Flur\u002FTechnikraum",[100,1256,1257,1259,1262,1267],{},[118,1258,367],{},[118,1260,1261],{},"⏚ mit PE",[118,1263,1264],{},[15,1265,1266],{},"Erdungsanschluss",[118,1268,1269],{},"Erdungspunkt",[100,1271,1272,1274,1277,1282],{},[118,1273,383],{},[118,1275,1276],{},"Kreis mit R",[118,1278,1279],{},[15,1280,1281],{},"Rauchmelder",[118,1283,1284],{},"Fluchtwege (Flur, Treppenhaus), regional unterschiedlich",[20,1286,1287],{},[11,1288,1289,1292],{},[15,1290,1291],{},"Tipp:"," Verwenden Sie für gängige Bauteile die AREI-Symbole aus Tabelle 2.23. Werden abweichende Symbole benötigt, müssen diese eindeutig sein und in der Legende erläutert werden — undefinierte bzw. nicht erklärte Symbole werden bei der Kontrolle beanstandet.",[41,1294],{},[44,1296,1298],{"id":1297},"schritt-3-komponenten-einzeichnen","Schritt 3: Komponenten einzeichnen",[11,1300,1301],{},"Jetzt platzieren Sie die Symbole im Grundriss. Folgende Regeln helfen bei der korrekten Positionierung:",[49,1303,1305],{"id":1304},"steckdosen","Steckdosen",[62,1307,1308,1313,1319,1325,1331],{},[65,1309,1310,1312],{},[15,1311,1194],{}," einzeichnen, an der tatsächlichen Position.",[65,1314,1315,1318],{},[15,1316,1317],{},"Küche:"," Tatsächliche Arbeitssteckdosen und feste Geräte einzeln erfassen; Anzahl und Einzelstromkreise aus Nutzung und Fachplanung ableiten.",[65,1320,1321,1324],{},[15,1322,1323],{},"Wohnräume:"," Tatsächlich geplante oder vorhandene Steckdosen einzeichnen; das AREI schreibt keine allgemeine Anzahl pro Fläche vor.",[65,1326,1327,1330],{},[15,1328,1329],{},"Badezimmer:"," Niederspannungs-Steckdosen erst ab Bereich 2 (nur bei Badewannen; die Steckdose muss durch eine Differenzstrom-Schutzeinrichtung mit sehr hoher Empfindlichkeit ≤ 10 mA oder jeweils einzeln durch einen Trenntransformator mit max. 100 W geschützt sein) bzw. außerhalb der Bereiche. Bei Duschen existiert Bereich 2 nicht (Art. 7.1.3.2 Nr. 3b, Art. 7.1.5.2d).",[65,1332,1333,1336],{},[15,1334,1335],{},"Außen:"," Tatsächliche äußere Einflüsse, erforderliche IP-Ausführung und anwendbaren 30-mA-Schutz fachlich bestimmen; ein pauschal eigener RCD ist keine allgemeine Aussage dieses Plans.",[49,1338,1340],{"id":1339},"schalter","Schalter",[62,1342,1343,1349,1354],{},[65,1344,1345,1348],{},[15,1346,1347],{},"Neben der Tür"," auf der Öffnungsseite, ca. 105 cm Höhe (Praxisempfehlung -- das AREI schreibt keine spezifische Schalthöhe vor, fordert aber 'leicht zugänglich').",[65,1350,1351,1353],{},[15,1352,1236],{}," bei Räumen mit mehreren Eingängen oder am Treppenanfang\u002F-ende.",[65,1355,1356,1357,78],{},"Verbinden Sie Schalter und zugehörige Leuchten mit einer ",[15,1358,1359],{},"gestrichelten Linie",[49,1361,1363],{"id":1362},"leuchten","Leuchten",[62,1365,1366,1372,1378],{},[65,1367,1368,1371],{},[15,1369,1370],{},"Deckenleuchten"," in die Raummitte oder an die geplante Position.",[65,1373,1374,1377],{},[15,1375,1376],{},"Wandleuchten"," an der Wandposition.",[65,1379,1380],{},"Alle tatsächlich geplanten oder vorhandenen Lichtpunkte einzeichnen; die benötigte Anzahl folgt Nutzung und Planung.",[49,1382,1384],{"id":1383},"regionale-brandschutzangaben","Regionale Brandschutzangaben",[11,1386,1387],{},"Rauchmelder können als getrennte Gebäudeinformation ergänzt werden. Anforderungen unterscheiden sich nach Region und Nutzung und werden gegen die aktuell zuständige amtliche Quelle geprüft. Sie sind keine pauschale Inhaltsvorgabe des AREI-Lageplans und werden im Dossier klar von elektrischen Stromkreisreferenzen getrennt.",[49,1389,1391],{"id":1390},"sonderverbraucher","Sonderverbraucher",[62,1393,1394,1400,1406],{},[65,1395,1396,1399],{},[15,1397,1398],{},"Wallbox"," (Elektroauto): Garage oder Außenwand, eigener Stromkreis.",[65,1401,1402,1405],{},[15,1403,1404],{},"Boiler\u002FDurchlauferhitzer:"," Eigener Stromkreis, Position einzeichnen.",[65,1407,1408,1411],{},[15,1409,1410],{},"Wärmepumpe\u002FKlimaanlage:"," Außeneinheit + Inneneinheit markieren.",[41,1413],{},[44,1415,1417],{"id":1416},"schritt-4-stromkreisnummern-zuordnen","Schritt 4: Stromkreisnummern zuordnen",[11,1419,1420,1421,1424],{},"Jede Komponente im Situationsplan erhält die ",[15,1422,1423],{},"gleiche Stromkreisnummer"," wie im Eindrahtschema. Das ist essentiell für die Zuordnung bei der Kontrolle.",[11,1426,1427],{},[15,1428,1429],{},"So funktioniert es:",[544,1431,1432,1435,1438],{},[65,1433,1434],{},"Das AREI kennzeichnet Elementarstromkreise per Großbuchstaben (A, B, C, ...) und die einzelnen Elemente (Lichtpunkt, Steckdose) per laufender Nummer — z. B. „A1, A2, ...\".",[65,1436,1437],{},"Schreiben Sie diese Kennung an jede Komponente im Situationsplan.",[65,1439,1440],{},"Eine vereinfachte reine Durchnummerierung (z. B. „K1\" oder „1\") ist als Praxis-Variante verbreitet, sofern Eindrahtschema und Situationsplan konsistent bleiben.",[11,1442,1443],{},[15,1444,1445],{},"Beispiel:",[62,1447,1448,1451,1454,1457],{},[65,1449,1450],{},"Stromkreis 1: Beleuchtung Erdgeschoss → Alle Leuchten im EG erhalten „1\".",[65,1452,1453],{},"Stromkreis 2: Steckdosen Wohnzimmer → Alle WZ-Steckdosen erhalten „2\".",[65,1455,1456],{},"Stromkreis 3: Steckdosen Küche → Alle KÜ-Steckdosen erhalten „3\".",[65,1458,1459],{},"Stromkreis 4: Dediziert Backofen → Eine Steckdose mit „4\".",[20,1461,1462,1471],{},[11,1463,1464,1466,1467,1470],{},[15,1465,975],{}," Die Nummern müssen zwischen Eindrahtschema und Situationsplan ",[15,1468,1469],{},"exakt übereinstimmen",". Inkonsistenzen sind einer der häufigsten Gründe für eine Beanstandung bei der Kontrolle.",[11,1472,1473,1476],{},[15,1474,1475],{},"Dokumentationspflicht:"," Art. 9.1.2 Nr. 1 (Einstrich-Schema) und Art. 9.1.2 Nr. 2 (Lageplan\u002FSituationsplan).",[41,1478],{},[44,1480,1482],{"id":1481},"schritt-5-legende-und-beschriftung","Schritt 5: Legende und Beschriftung",[11,1484,1485],{},"Ergänzen Sie Ihren Plan um:",[62,1487,1488,1494,1500,1506],{},[65,1489,1490,1493],{},[15,1491,1492],{},"Legende"," mit allen verwendeten Symbolen und ihrer Bedeutung.",[65,1495,1496,1499],{},[15,1497,1498],{},"Titelblock"," (Cartouche) mit: Name des Eigentümers, Adresse, Datum, Planersteller, Maßstab.",[65,1501,1502,1505],{},[15,1503,1504],{},"Nordpfeil"," (optional, aber hilfreich).",[65,1507,1508,1511],{},[15,1509,1510],{},"Stockwerk-Kennzeichnung"," bei mehrgeschossigen Gebäuden (ein Plan pro Etage).",[41,1513],{},[44,1515,1517],{"id":1516},"häufige-fehler","Häufige Fehler",[94,1519,1520,1533],{},[97,1521,1522],{},[100,1523,1524,1527,1530],{},[103,1525,1526],{},"Fehler",[103,1528,1529],{},"Konsequenz",[103,1531,1532],{},"Lösung",[113,1534,1535,1546,1557,1568,1578,1589,1600],{},[100,1536,1537,1540,1543],{},[118,1538,1539],{},"Regionale Brandschutzangaben als AREI-Regel behandeln",[118,1541,1542],{},"Falsche Prüfgrundlage",[118,1544,1545],{},"Separat gegen aktuelle regionale Quelle prüfen und kennzeichnen",[100,1547,1548,1551,1554],{},[118,1549,1550],{},"Außensteckdose pauschal behandeln",[118,1552,1553],{},"Äußere Einflüsse oder Schutz können falsch sein",[118,1555,1556],{},"IP-Ausführung und 30-mA-Schutz projektspezifisch prüfen",[100,1558,1559,1562,1565],{},[118,1560,1561],{},"Fehlende Beschriftung \u002F Stromkreisnummern",[118,1563,1564],{},"Beanstandung",[118,1566,1567],{},"Jede Komponente nummerieren",[100,1569,1570,1573,1575],{},[118,1571,1572],{},"Undefinierte\u002Fnicht erklärte Symbole",[118,1574,1564],{},[118,1576,1577],{},"AREI-Symbole (Tab. 2.23) nutzen; abweichende Symbole eindeutig wählen und in der Legende erläutern",[100,1579,1580,1583,1586],{},[118,1581,1582],{},"Schalter auf falscher Türseite",[118,1584,1585],{},"Unpraktisch (kein AREI-Verstoß)",[118,1587,1588],{},"Öffnungsrichtung prüfen",[100,1590,1591,1594,1597],{},[118,1592,1593],{},"Badezimmer-Steckdose falsch zum Bereich dargestellt",[118,1595,1596],{},"Plan und Ausführung können einen sicherheitsrelevanten Befund auslösen",[118,1598,1599],{},"Bereiche und Schutz nach aktuellem Kapitel 7.1 fachlich prüfen",[100,1601,1602,1605,1607],{},[118,1603,1604],{},"Keine Legende",[118,1606,1564],{},[118,1608,1609],{},"Symboltabelle beifügen",[41,1611],{},[44,1613,1615],{"id":1614},"checkliste-vor-der-abgabe","Checkliste vor der Abgabe",[62,1617,1619,1625,1631,1637,1643,1649,1655,1661,1667,1673],{"className":1618},[733],[65,1620,1622,1624],{"className":1621},[737],[739,1623],{"disabled":741,"type":742}," Alle Räume beschriftet",[65,1626,1628,1630],{"className":1627},[737],[739,1629],{"disabled":741,"type":742}," Alle Steckdosen, Schalter, Leuchten eingezeichnet",[65,1632,1634,1636],{"className":1633},[737],[739,1635],{"disabled":741,"type":742}," Regionale Brandschutzinformationen, falls dargestellt, getrennt geprüft und gekennzeichnet",[65,1638,1640,1642],{"className":1639},[737],[739,1641],{"disabled":741,"type":742}," Außensteckdosen mit projektspezifischer IP- und Schutzbewertung erfasst",[65,1644,1646,1648],{"className":1645},[737],[739,1647],{"disabled":741,"type":742}," Stromkreisnummern an jeder Komponente",[65,1650,1652,1654],{"className":1651},[737],[739,1653],{"disabled":741,"type":742}," Nummern stimmen mit Eindrahtschema überein",[65,1656,1658,1660],{"className":1657},[737],[739,1659],{"disabled":741,"type":742}," AREI-Symbole verwendet (Tabelle 2.23)",[65,1662,1664,1666],{"className":1663},[737],[739,1665],{"disabled":741,"type":742}," Legende vorhanden",[65,1668,1670,1672],{"className":1669},[737],[739,1671],{"disabled":741,"type":742}," Titelblock mit Name, Adresse, Datum",[65,1674,1676,1678],{"className":1675},[737],[739,1677],{"disabled":741,"type":742}," Ein Plan pro Stockwerk",[44,1680,1682],{"id":1681},"praxisprüfung-stimmen-plan-und-gebäude-wirklich-überein","Praxisprüfung: Stimmen Plan und Gebäude wirklich überein?",[11,1684,1685],{},"Gehen Sie nach dem Zeichnen mit dem Plan durch das Gebäude. Beginnen Sie am Verteiler und folgen Sie jedem Stromkreis. Prüfen Sie nicht nur, ob eine Steckdose vorhanden ist, sondern auch, ob Mehrfachsteckdose, geschaltete Steckdose, Verbindungsdose, fester Anschluss oder Lichtpunkt richtig unterschieden sind. Bei Schaltern muss die Referenz erkennen lassen, welchen Lichtpunkt oder welches Gerät sie steuern. Geräte hinter Einbaumöbeln, Außenelemente, Technikräume und Nebengebäude werden leicht übersehen.",[11,1687,1688],{},"Danach folgt der Kreuzvergleich mit dem Eindrahtschema. Ein Element mit Kennung A3 im Lageplan muss dort als dasselbe Element im Stromkreis A erscheinen. Doppelte Kennungen, übersprungene Nummern und nachträglich verschobene Geräte sind typische Ursachen für widersprüchliche Dokumente. Verwenden Sie bei mehreren Etagen oder Gebäudeteilen eine nachvollziehbare Blattstruktur und behalten Sie Nummer, Fassung und Fassungsdatum auf jedem ausgegebenen Plan bei.",[11,1690,1691],{},"Der Lageplan bildet den realen Zustand ab, nicht bloß die ursprüngliche Absicht. Markieren Sie Änderungen daher erst als abgeschlossen, nachdem Leitungsführung und Geräteposition auf der Baustelle geprüft wurden. Bei einer kleinen, nicht wesentlichen Änderung kann nach Buch 1 für das Eindrahtschema eine kurze Beschreibung genügen; die Änderung oder Erweiterung bleibt aber im Lageplan darzustellen. Bei wesentlichen Änderungen oder Erweiterungen werden Einstrich-Schema und Lageplan erstellt beziehungsweise aktualisiert und die betroffenen Arbeiten vor Ingebrauchnahme geprüft.",[44,1693,1695],{"id":1694},"grenzen-die-der-plan-nicht-entscheiden-kann","Grenzen, die der Plan nicht entscheiden kann",[11,1697,1698],{},"Ein Symbol beweist weder richtige Montagehöhe noch Schutzart, Badezimmerbereich, Erdungsqualität oder korrekte Abschaltzeit. Solche Eigenschaften benötigen Ortsprüfung, Messungen und gegebenenfalls Herstellerunterlagen. Rauchmelderpflichten stammen zudem aus regionalem Bau- und Wohnrecht und dürfen nicht pauschal als Lageplanpflicht des AREI behandelt werden. Der Plan kann Rauchmelder als hilfreiche Gebäudeelemente zeigen, doch die elektrische Kontrolle und regionale Anforderungen bleiben getrennte Fragen.",[11,1700,1701],{},"PlanElec hält Geräteposition und elektrische Zuordnung in einem Projektmodell zusammen. Prüfen Sie dennoch jede vorgeschlagene Verbindung. Nicht platzierte, noch keinem Stromkreis zugeordnete oder nur als Referenz importierte Elemente dürfen nicht stillschweigend als fertig gelten. Der orientierende Selbstcheck deckt nur unterstützte Regeln ab; die offizielle Beurteilung erfolgt durch einen zugelassenen Kontrollorganismus.",[44,1703,1705],{"id":1704},"amtliche-quelle","Amtliche Quelle",[49,1707,1709],{"id":1708},"abnahmefähige-lesbarkeit-vorbereiten","Abnahmefähige Lesbarkeit vorbereiten",[11,1711,1712],{},"Drucken oder exportieren Sie den Plan einmal in der vorgesehenen Blattgröße. Symbole, Referenzen und Raumgrenzen müssen ohne extremes Zoomen unterscheidbar bleiben. Überlagerte Kennungen werden versetzt, aber mit einer klaren Bezugslinie verbunden. Eine Farbe kann bei der Bearbeitung helfen, darf jedoch nicht die einzige Bedeutung tragen, weil Ausdrucke schwarzweiß sein können.",[11,1714,1715],{},"Führen Sie eine offene-Punkte-Liste für nicht zugängliche Dosen, unbekannte Schalterbeziehungen oder vermutete Leitungswege. Solche Punkte werden vor der finalen Fassung geklärt oder sichtbar als unbekannt behandelt. Ein präzise markierter Datenmangel ist fachlich ehrlicher als ein Symbol an einer geschätzten Position. Lassen Sie zuletzt eine zweite Person stichprobenartig Referenzen zwischen Lageplan, Einstrich-Schema und Verteilerbeschriftung verfolgen.",[62,1717,1718,1724],{},[65,1719,1720],{},[830,1721,1723],{"href":832,"rel":1722},[834],"FÖD Wirtschaft: RGIE\u002FAREI Buch 1, aktuelle amtliche Veröffentlichung",[65,1725,1726],{},"Relevant sind insbesondere Buch 1 V06, Abschnitt 3.1.2 und Tabelle 2.23. Das AREI erlaubt ein anderes eindeutig identifizierbares Symbol, wenn Tabelle 2.23 keines enthält und die Legende es erklärt.",[41,1728],{},[44,1730,1732],{"id":1731},"verwandte-artikel","Verwandte Artikel",[62,1734,1735,1741,1747],{},[65,1736,1737],{},[830,1738,1740],{"href":1739},"\u002Fde\u002Fblog\u002Fwas-ist-eindrahtschema","Was ist ein Eindrahtschema?",[65,1742,1743],{},[830,1744,1746],{"href":1745},"\u002Fde\u002Fblog\u002Felektrische-kontrolle","Elektrische Kontrolle in Belgien",[65,1748,1749],{},[830,1750,1752],{"href":1751},"\u002Fde\u002Fblog\u002Fschaltschrank-planen-aufbau","Schaltschrank planen: Aufbau und Dimensionierung",[41,1754],{},[11,1756,1757],{},[29,1758,1759,1760,1762,1763],{},"Mit ",[15,1761,874],{}," erstellen Sie Ihren Situationsplan direkt aus dem Grundriss — Räume zeichnen, Geräte per Drag & Drop platzieren, AREI-Symbole werden automatisch verwendet. ",[830,1764,1765],{"href":878},"Jetzt kostenlos testen →",{"title":881,"searchDepth":882,"depth":882,"links":1767},[1768,1772,1773,1780,1781,1782,1783,1784,1785,1786,1789],{"id":962,"depth":882,"text":963,"children":1769},[1770,1771],{"id":966,"depth":887,"text":967},{"id":1001,"depth":887,"text":1002},{"id":1107,"depth":882,"text":1108},{"id":1297,"depth":882,"text":1298,"children":1774},[1775,1776,1777,1778,1779],{"id":1304,"depth":887,"text":1305},{"id":1339,"depth":887,"text":1340},{"id":1362,"depth":887,"text":1363},{"id":1383,"depth":887,"text":1384},{"id":1390,"depth":887,"text":1391},{"id":1416,"depth":882,"text":1417},{"id":1481,"depth":882,"text":1482},{"id":1516,"depth":882,"text":1517},{"id":1614,"depth":882,"text":1615},{"id":1681,"depth":882,"text":1682},{"id":1694,"depth":882,"text":1695},{"id":1704,"depth":882,"text":1705,"children":1787},[1788],{"id":1708,"depth":887,"text":1709},{"id":1731,"depth":882,"text":1732},"Komplette Anleitung für einen belastbaren Situationsplan: vom Grundriss über AREI-Symbole und Stromkreisreferenzen bis zum fachlich geprüften Dokument.","de",{},"\u002Fblog\u002Fdraw-situation-plan.de",{"title":929,"description":1790},"situationsplan-zeichnen-anleitung","blog\u002Fdraw-situation-plan.de",[1798,1799,1800,1801,1802,1803,1804],"situationsplan","AREI","symbole","anleitung","zeichnen","elektroplan","grundriss","hkZq6XS7LruPXf48TTaBKsx4f9v98z7RdhGLCf9JSSs",{"id":1807,"title":1808,"articleId":6,"body":1809,"category":905,"date":906,"description":2654,"extension":908,"lastUpdated":909,"locale":2655,"meta":2656,"navigation":741,"path":2657,"publishDate":906,"readTime":913,"refreshInterval":914,"seo":2658,"slug":2659,"stem":2660,"tags":2661,"__hash__":2667},"blog\u002Fblog\u002Fdraw-situation-plan.en.md","Draw a Situation Plan: Step-by-Step Guide According to AREI\u002FRGIE",{"type":8,"value":1810,"toc":2632},[1811,1818,1834,1837,1839,1843,1847,1850,1855,1877,1881,1884,1979,1981,1985,1992,2159,2167,2169,2173,2176,2180,2213,2217,2237,2241,2258,2262,2265,2269,2289,2291,2295,2302,2307,2318,2323,2337,2354,2356,2360,2363,2389,2391,2395,2486,2488,2492,2555,2559,2562,2565,2568,2572,2575,2578,2582,2593,2595,2599,2619,2621],[11,1812,1813,1814,1817],{},"The situation plan (also called position plan or plan de situation) shows ",[15,1815,1816],{},"where exactly"," each electrical component is located in your building. For a new domestic installation and a substantial change or extension, it is prepared with the single-line diagram. Existing-installation and minor-change cases have defined rules; the approved control body assesses the actual dossier.",[20,1819,1820],{},[11,1821,1822,1825,1826,1829,1830,1833],{},[15,1823,1824],{},"In brief:"," While the single-line diagram shows the ",[29,1827,1828],{},"logical wiring"," (which switch controls which light, via which circuit), the situation plan shows the ",[29,1831,1832],{},"physical position"," of each component on the floor plan.",[11,1835,1836],{},"This guide explains how to prepare a reviewable situation plan step by step. Only an approved control body can decide whether the complete dossier and the installed work comply with the applicable rules.",[41,1838],{},[44,1840,1842],{"id":1841},"step-1-prepare-the-floor-plan","Step 1: Prepare the Floor Plan",[49,1844,1846],{"id":1845},"dimensions-and-scale","Dimensions and Scale",[11,1848,1849],{},"The floor plan forms the basis of your situation plan. You can take it from a construction plan or draw it yourself.",[11,1851,1852],{},[15,1853,1854],{},"Important:",[62,1856,1857,1864,1870],{},[65,1858,1859,1860,1863],{},"Use a ",[15,1861,1862],{},"uniform scale"," (common: 1:50 or 1:100).",[65,1865,1866,1867,78],{},"Draw all ",[15,1868,1869],{},"walls, doors, and windows",[65,1871,1872,1873,1876],{},"Mark the ",[15,1874,1875],{},"opening direction"," of doors (quarter circle) — this affects switch placement.",[49,1878,1880],{"id":1879},"label-the-rooms","Label the Rooms",[11,1882,1883],{},"Give each room its designation and ideally its area:",[94,1885,1886,1899],{},[97,1887,1888],{},[100,1889,1890,1893,1896],{},[103,1891,1892],{},"Abbreviation",[103,1894,1895],{},"Room",[103,1897,1898],{},"Typical Area",[113,1900,1901,1911,1921,1931,1941,1951,1959,1969],{},[100,1902,1903,1906,1909],{},[118,1904,1905],{},"LR",[118,1907,1908],{},"Living Room",[118,1910,126],{},[100,1912,1913,1916,1919],{},[118,1914,1915],{},"KI",[118,1917,1918],{},"Kitchen",[118,1920,137],{},[100,1922,1923,1926,1929],{},[118,1924,1925],{},"BR",[118,1927,1928],{},"Bedroom",[118,1930,148],{},[100,1932,1933,1936,1939],{},[118,1934,1935],{},"BA",[118,1937,1938],{},"Bathroom",[118,1940,159],{},[100,1942,1943,1946,1949],{},[118,1944,1945],{},"HA",[118,1947,1948],{},"Hallway",[118,1950,170],{},[100,1952,1953,1955,1957],{},[118,1954,1077],{},[118,1956,178],{},[118,1958,181],{},[100,1960,1961,1964,1967],{},[118,1962,1963],{},"BS",[118,1965,1966],{},"Basement",[118,1968,192],{},[100,1970,1971,1974,1977],{},[118,1972,1973],{},"EX",[118,1975,1976],{},"Exterior",[118,1978,192],{},[41,1980],{},[44,1982,1984],{"id":1983},"step-2-use-areirgie-symbols","Step 2: Use AREI\u002FRGIE Symbols",[11,1986,1987,1988,1991],{},"AREI\u002FRGIE ",[15,1989,1990],{},"Table 2.23"," gives a non-exhaustive list of symbols. If a component has no listed symbol, another clearly identifiable symbol may be used when the legend defines it. Ten useful symbol groups for a position plan are:",[94,1993,1994,2008],{},[97,1995,1996],{},[100,1997,1998,2001,2003,2005],{},[103,1999,2000],{},"No.",[103,2002,1127],{},[103,2004,230],{},[103,2006,2007],{},"Usage",[113,2009,2010,2025,2039,2054,2069,2084,2099,2114,2129,2144],{},[100,2011,2012,2014,2017,2022],{},[118,2013,240],{},[118,2015,2016],{},"⏚ Semicircle",[118,2018,2019],{},[15,2020,2021],{},"Single socket outlet",[118,2023,2024],{},"Mark wall position",[100,2026,2027,2029,2032,2037],{},[118,2028,256],{},[118,2030,2031],{},"⏚⏚ Double semicircle",[118,2033,2034],{},[15,2035,2036],{},"Double socket outlet",[118,2038,2024],{},[100,2040,2041,2043,2046,2051],{},[118,2042,271],{},[118,2044,2045],{},"○ with cross",[118,2047,2048],{},[15,2049,2050],{},"Ceiling light",[118,2052,2053],{},"Centre of room\u002Fposition",[100,2055,2056,2058,2061,2066],{},[118,2057,287],{},[118,2059,2060],{},"─○ with line",[118,2062,2063],{},[15,2064,2065],{},"Wall light",[118,2067,2068],{},"On the wall",[100,2070,2071,2073,2076,2081],{},[118,2072,303],{},[118,2074,2075],{},"Switch symbol",[118,2077,2078],{},[15,2079,2080],{},"Single-pole switch",[118,2082,2083],{},"Next to door (opening side)",[100,2085,2086,2088,2091,2096],{},[118,2087,319],{},[118,2089,2090],{},"Switch symbol with 2 arrows",[118,2092,2093],{},[15,2094,2095],{},"Series switch",[118,2097,2098],{},"Controls 2 luminaires",[100,2100,2101,2103,2106,2111],{},[118,2102,335],{},[118,2104,2105],{},"Switch symbol with line",[118,2107,2108],{},[15,2109,2110],{},"Two-way switch",[118,2112,2113],{},"Two locations, one light",[100,2115,2116,2118,2121,2126],{},[118,2117,351],{},[118,2119,2120],{},"Rectangle with lightning",[118,2122,2123],{},[15,2124,2125],{},"Distribution board",[118,2127,2128],{},"Usually hallway\u002Futility room",[100,2130,2131,2133,2136,2141],{},[118,2132,367],{},[118,2134,2135],{},"⏚ with PE",[118,2137,2138],{},[15,2139,2140],{},"Earth connection",[118,2142,2143],{},"Earthing point",[100,2145,2146,2148,2151,2156],{},[118,2147,383],{},[118,2149,2150],{},"Circle with R",[118,2152,2153],{},[15,2154,2155],{},"Smoke detector",[118,2157,2158],{},"Escape routes (hallway, staircase), regionally varies",[20,2160,2161],{},[11,2162,2163,2166],{},[15,2164,2165],{},"Tip:"," Use the AREI\u002FRGIE symbols from Table 2.23 for common components. If deviating symbols are needed, they must be clearly identifiable and explained in the legend — undefined or unexplained symbols will be rejected during inspection.",[41,2168],{},[44,2170,2172],{"id":2171},"step-3-draw-the-components","Step 3: Draw the Components",[11,2174,2175],{},"Now place the symbols on the floor plan. The following rules help with correct positioning:",[49,2177,2179],{"id":2178},"socket-outlets","Socket Outlets",[62,2181,2182,2189,2195,2201,2207],{},[65,2183,2184,2185,2188],{},"Draw ",[15,2186,2187],{},"on the wall"," at the actual position.",[65,2190,2191,2194],{},[15,2192,2193],{},"Kitchen:"," Record the actual worktop outlets and fixed appliances individually; derive quantities and dedicated circuits from use and professional design.",[65,2196,2197,2200],{},[15,2198,2199],{},"Living spaces:"," Draw the actual planned or installed sockets; AREI\u002FRGIE sets no general count per floor area.",[65,2202,2203,2206],{},[15,2204,2205],{},"Bathroom:"," Low-voltage sockets only from Zone 2 (bathtubs only; the socket must be protected by a residual current device (RCD) of very high sensitivity ≤ 10 mA, or individually by an isolating transformer of max. 100 W) or outside the zones. For showers, Zone 2 does not exist (Art. 7.1.3.2 Nr. 3b, Art. 7.1.5.2d).",[65,2208,2209,2212],{},[15,2210,2211],{},"Outdoor:"," Professionally determine external influences, required IP rating and applicable 30 mA protection; a dedicated RCD is not a blanket conclusion of the position plan.",[49,2214,2216],{"id":2215},"switches","Switches",[62,2218,2219,2225,2231],{},[65,2220,2221,2224],{},[15,2222,2223],{},"Next to the door"," on the opening side, approximately 105 cm height (practical recommendation — the AREI does not prescribe a specific switch height, but requires 'easily accessible').",[65,2226,2227,2230],{},[15,2228,2229],{},"Two-way switches"," for rooms with multiple entrances or at the top\u002Fbottom of stairs.",[65,2232,2233,2234,78],{},"Connect switches and associated luminaires with a ",[15,2235,2236],{},"dashed line",[49,2238,2240],{"id":2239},"lighting-points","Lighting Points",[62,2242,2243,2249,2255],{},[65,2244,2245,2248],{},[15,2246,2247],{},"Ceiling lights"," in the centre of the room or at the planned position.",[65,2250,2251,2254],{},[15,2252,2253],{},"Wall lights"," at the wall position.",[65,2256,2257],{},"Draw every actual planned or installed lighting point; quantity follows use and design.",[49,2259,2261],{"id":2260},"regional-fire-safety-information","Regional fire-safety information",[11,2263,2264],{},"Smoke alarms may be added as a separate building overlay. Requirements differ by region and use and must be checked against the current competent official source. They are not a blanket AREI\u002FRGIE position-plan field and should remain distinguishable from electrical circuit references.",[49,2266,2268],{"id":2267},"special-consumers","Special Consumers",[62,2270,2271,2277,2283],{},[65,2272,2273,2276],{},[15,2274,2275],{},"EV charger"," (electric vehicle): garage or exterior wall, dedicated circuit.",[65,2278,2279,2282],{},[15,2280,2281],{},"Water heater\u002FBoiler:"," Dedicated circuit, mark the position.",[65,2284,2285,2288],{},[15,2286,2287],{},"Heat pump\u002FAir conditioning:"," Mark outdoor unit + indoor unit.",[41,2290],{},[44,2292,2294],{"id":2293},"step-4-assign-circuit-numbers","Step 4: Assign Circuit Numbers",[11,2296,2297,2298,2301],{},"Each component on the situation plan receives the ",[15,2299,2300],{},"same circuit number"," as in the single-line diagram. This is essential for identification during inspection.",[11,2303,2304],{},[15,2305,2306],{},"How it works:",[544,2308,2309,2312,2315],{},[65,2310,2311],{},"The AREI identifies elementary circuits by a capital letter (A, B, C, ...) and the individual elements (lighting point, socket) by a sequential number — e.g. \"A1, A2, ...\".",[65,2313,2314],{},"Write this identifier next to each component on the situation plan.",[65,2316,2317],{},"A simplified plain numbering (e.g. \"C1\" or \"1\") is common in practice, as long as the single-line diagram and situation plan remain consistent.",[11,2319,2320],{},[15,2321,2322],{},"Example:",[62,2324,2325,2328,2331,2334],{},[65,2326,2327],{},"Circuit 1: Ground floor lighting → All ground floor luminaires get \"1\".",[65,2329,2330],{},"Circuit 2: Living room sockets → All living room sockets get \"2\".",[65,2332,2333],{},"Circuit 3: Kitchen sockets → All kitchen sockets get \"3\".",[65,2335,2336],{},"Circuit 4: Dedicated oven → One socket with \"4\".",[20,2338,2339,2348],{},[11,2340,2341,2343,2344,2347],{},[15,2342,1854],{}," The numbers must match ",[15,2345,2346],{},"exactly"," between the single-line diagram and the situation plan. Inconsistencies are one of the most common reasons for remarks during inspection.",[11,2349,2350,2353],{},[15,2351,2352],{},"Documentation requirement:"," Art. 9.1.2 Nr. 1 (single-line diagram) and Art. 9.1.2 Nr. 2 (situation plan).",[41,2355],{},[44,2357,2359],{"id":2358},"step-5-legend-and-labelling","Step 5: Legend and Labelling",[11,2361,2362],{},"Complete your plan with:",[62,2364,2365,2371,2377,2383],{},[65,2366,2367,2370],{},[15,2368,2369],{},"Legend"," with all symbols used and their meaning.",[65,2372,2373,2376],{},[15,2374,2375],{},"Title block"," (cartouche) with: owner's name, address, date, plan creator, scale.",[65,2378,2379,2382],{},[15,2380,2381],{},"North arrow"," (optional, but helpful).",[65,2384,2385,2388],{},[15,2386,2387],{},"Floor indication"," for multi-storey buildings (one plan per floor).",[41,2390],{},[44,2392,2394],{"id":2393},"common-mistakes","Common Mistakes",[94,2396,2397,2409],{},[97,2398,2399],{},[100,2400,2401,2404,2407],{},[103,2402,2403],{},"Mistake",[103,2405,2406],{},"Consequence",[103,2408,646],{},[113,2410,2411,2422,2433,2444,2454,2465,2476],{},[100,2412,2413,2416,2419],{},[118,2414,2415],{},"Treating regional fire rules as an AREI rule",[118,2417,2418],{},"Wrong inspection basis",[118,2420,2421],{},"Verify separately against the current regional source and label it",[100,2423,2424,2427,2430],{},[118,2425,2426],{},"Treating every outdoor socket alike",[118,2428,2429],{},"External influences or protection may be wrong",[118,2431,2432],{},"Assess IP rating and 30 mA protection for the project",[100,2434,2435,2438,2441],{},[118,2436,2437],{},"Missing labels \u002F circuit numbers",[118,2439,2440],{},"Remark",[118,2442,2443],{},"Number every component",[100,2445,2446,2449,2451],{},[118,2447,2448],{},"Undefined\u002Funexplained symbols",[118,2450,2440],{},[118,2452,2453],{},"Use AREI symbols (Table 2.23); choose deviating symbols clearly and explain them in the legend",[100,2455,2456,2459,2462],{},[118,2457,2458],{},"Switch on wrong side of door",[118,2460,2461],{},"Impractical (not an AREI violation)",[118,2463,2464],{},"Check opening direction",[100,2466,2467,2470,2473],{},[118,2468,2469],{},"Bathroom socket shown in the wrong zone",[118,2471,2472],{},"Plan and installation can produce a safety finding",[118,2474,2475],{},"Professionally check zones and protection against current chapter 7.1",[100,2477,2478,2481,2483],{},[118,2479,2480],{},"No legend",[118,2482,2440],{},[118,2484,2485],{},"Include symbol table",[41,2487],{},[44,2489,2491],{"id":2490},"checklist-before-submission","Checklist Before Submission",[62,2493,2495,2501,2507,2513,2519,2525,2531,2537,2543,2549],{"className":2494},[733],[65,2496,2498,2500],{"className":2497},[737],[739,2499],{"disabled":741,"type":742}," All rooms labelled",[65,2502,2504,2506],{"className":2503},[737],[739,2505],{"disabled":741,"type":742}," All sockets, switches, lighting points drawn",[65,2508,2510,2512],{"className":2509},[737],[739,2511],{"disabled":741,"type":742}," Regional fire-safety information, if shown, checked separately and labelled",[65,2514,2516,2518],{"className":2515},[737],[739,2517],{"disabled":741,"type":742}," Outdoor sockets recorded with project-specific IP and protection assessment",[65,2520,2522,2524],{"className":2521},[737],[739,2523],{"disabled":741,"type":742}," Circuit numbers on every component",[65,2526,2528,2530],{"className":2527},[737],[739,2529],{"disabled":741,"type":742}," Numbers match the single-line diagram",[65,2532,2534,2536],{"className":2533},[737],[739,2535],{"disabled":741,"type":742}," AREI symbols used (Table 2.23)",[65,2538,2540,2542],{"className":2539},[737],[739,2541],{"disabled":741,"type":742}," Legend present",[65,2544,2546,2548],{"className":2545},[737],[739,2547],{"disabled":741,"type":742}," Title block with name, address, date",[65,2550,2552,2554],{"className":2551},[737],[739,2553],{"disabled":741,"type":742}," One plan per floor",[44,2556,2558],{"id":2557},"site-walk-does-the-drawing-match-the-building","Site walk: does the drawing match the building?",[11,2560,2561],{},"Walk through the building with the draft. Start at the distribution board and follow every circuit. Check more than the presence of a socket: distinguish a multiple socket, switched socket, junction box, fixed connection and lighting point correctly. A switch reference should reveal which light or item it controls. Devices behind fitted furniture, exterior points, plant rooms and outbuildings are easy to miss.",[11,2563,2564],{},"Next, cross-check the single-line diagram. An item labelled A3 on the position plan must be the same A3 on circuit A in the diagram. Duplicate labels, skipped numbers and devices moved after the first survey commonly create contradictory records. For several floors or buildings, use a clear sheet structure and retain the document number, revision and revision date on every issued plan.",[11,2566,2567],{},"The position plan records the real installation, not merely the original design. Mark a change as complete only after the cable route and device location have been checked on site. For a minor, non-substantial domestic change, Book 1 can allow a short description instead of a new single-line diagram; the change or extension still has to appear on the position plan. Substantial changes or extensions require updated diagrams and inspection of the affected work before it is put into service.",[44,2569,2571],{"id":2570},"what-a-position-symbol-cannot-prove","What a position symbol cannot prove",[11,2573,2574],{},"A symbol does not prove mounting height, enclosure rating, bathroom-zone suitability, earthing quality or disconnection time. Those properties require site inspection, measurements and sometimes manufacturer documents. Smoke-alarm duties also arise from regional building and housing rules, not from a blanket AREI position-plan rule. They can be useful building information without being misrepresented as an electrical-diagram requirement.",[11,2576,2577],{},"PlanElec keeps device positions and electrical assignments in one project model, but every proposed link still needs review. Unplaced devices, items without a circuit and imported reference graphics must not silently look finished. The advisory self-check covers supported rules only; official assessment remains with an approved control body.",[44,2579,2581],{"id":2580},"official-source","Official source",[62,2583,2584,2590],{},[65,2585,2586],{},[830,2587,2589],{"href":832,"rel":2588},[834],"FPS Economy: current official RGIE\u002FAREI Book 1 publication",[65,2591,2592],{},"The relevant basis is Book 1 V06 section 3.1.2 and Table 2.23. Where Table 2.23 has no symbol, the AREI\u002FRGIE permits another unambiguous symbol defined in the legend.",[41,2594],{},[44,2596,2598],{"id":2597},"related-articles","Related Articles",[62,2600,2601,2607,2613],{},[65,2602,2603],{},[830,2604,2606],{"href":2605},"\u002Fen\u002Fblog\u002Fwhat-is-single-line-diagram","What Is a Single-Line Diagram?",[65,2608,2609],{},[830,2610,2612],{"href":2611},"\u002Fen\u002Fblog\u002Felectrical-inspection","Electrical Inspection in Belgium",[65,2614,2615],{},[830,2616,2618],{"href":2617},"\u002Fen\u002Fblog\u002Fdistribution-board-planning-guide","Distribution Board Planning: Layout and Sizing",[41,2620],{},[11,2622,2623],{},[29,2624,2625,2626,2628,2629],{},"With ",[15,2627,874],{},", create your situation plan directly from the floor plan — draw rooms, drag and drop devices, AREI symbols are used automatically. ",[830,2630,2631],{"href":878},"Try for free →",{"title":881,"searchDepth":882,"depth":882,"links":2633},[2634,2638,2639,2646,2647,2648,2649,2650,2651,2652,2653],{"id":1841,"depth":882,"text":1842,"children":2635},[2636,2637],{"id":1845,"depth":887,"text":1846},{"id":1879,"depth":887,"text":1880},{"id":1983,"depth":882,"text":1984},{"id":2171,"depth":882,"text":2172,"children":2640},[2641,2642,2643,2644,2645],{"id":2178,"depth":887,"text":2179},{"id":2215,"depth":887,"text":2216},{"id":2239,"depth":887,"text":2240},{"id":2260,"depth":887,"text":2261},{"id":2267,"depth":887,"text":2268},{"id":2293,"depth":882,"text":2294},{"id":2358,"depth":882,"text":2359},{"id":2393,"depth":882,"text":2394},{"id":2490,"depth":882,"text":2491},{"id":2557,"depth":882,"text":2558},{"id":2570,"depth":882,"text":2571},{"id":2580,"depth":882,"text":2581},{"id":2597,"depth":882,"text":2598},"Complete guide to a reviewable situation plan: from floor-plan preparation through AREI\u002FRGIE symbols and circuit references to professional review.","en",{},"\u002Fblog\u002Fdraw-situation-plan.en",{"title":1808,"description":2654},"draw-situation-plan-guide","blog\u002Fdraw-situation-plan.en",[2662,1799,2663,905,2664,2665,2666],"situation plan","symbols","drawing","electrical plan","floor plan","qpyo4C7vpPkqVOYtek9krFnEECkxCfKuJsOeO7aWJQc",{"id":4,"title":5,"articleId":6,"body":2669,"category":905,"date":906,"description":907,"extension":908,"lastUpdated":909,"locale":910,"meta":3301,"navigation":741,"path":912,"publishDate":906,"readTime":913,"refreshInterval":914,"seo":3302,"slug":916,"stem":917,"tags":3303,"__hash__":925},{"type":8,"value":2670,"toc":3279},[2671,2675,2685,2687,2689,2691,2693,2695,2699,2713,2715,2717,2795,2797,2799,2803,2939,2945,2947,2949,2951,2953,2975,2977,2991,2993,3005,3007,3009,3011,3025,3027,3029,3033,3037,3045,3049,3059,3071,3073,3075,3077,3095,3097,3099,3169,3171,3173,3226,3228,3230,3232,3234,3236,3238,3240,3242,3251,3253,3255,3269,3271],[11,2672,13,2673,18],{},[15,2674,17],{},[20,2676,2677],{},[11,2678,2679,27,2681,32,2683,36],{},[15,2680,26],{},[29,2682,31],{},[29,2684,35],{},[11,2686,39],{},[41,2688],{},[44,2690,47],{"id":46},[49,2692,52],{"id":51},[11,2694,55],{},[11,2696,2697],{},[15,2698,60],{},[62,2700,2701,2705,2709],{},[65,2702,67,2703,71],{},[15,2704,70],{},[65,2706,74,2707,78],{},[15,2708,77],{},[65,2710,81,2711,85],{},[15,2712,84],{},[49,2714,89],{"id":88},[11,2716,92],{},[94,2718,2719,2729],{},[97,2720,2721],{},[100,2722,2723,2725,2727],{},[103,2724,105],{},[103,2726,108],{},[103,2728,111],{},[113,2730,2731,2739,2747,2755,2763,2771,2779,2787],{},[100,2732,2733,2735,2737],{},[118,2734,120],{},[118,2736,123],{},[118,2738,126],{},[100,2740,2741,2743,2745],{},[118,2742,131],{},[118,2744,134],{},[118,2746,137],{},[100,2748,2749,2751,2753],{},[118,2750,142],{},[118,2752,145],{},[118,2754,148],{},[100,2756,2757,2759,2761],{},[118,2758,153],{},[118,2760,156],{},[118,2762,159],{},[100,2764,2765,2767,2769],{},[118,2766,164],{},[118,2768,167],{},[118,2770,170],{},[100,2772,2773,2775,2777],{},[118,2774,175],{},[118,2776,178],{},[118,2778,181],{},[100,2780,2781,2783,2785],{},[118,2782,186],{},[118,2784,189],{},[118,2786,192],{},[100,2788,2789,2791,2793],{},[118,2790,197],{},[118,2792,200],{},[118,2794,192],{},[41,2796],{},[44,2798,208],{"id":207},[11,2800,211,2801,215],{},[15,2802,214],{},[94,2804,2805,2817],{},[97,2806,2807],{},[100,2808,2809,2811,2813,2815],{},[103,2810,224],{},[103,2812,227],{},[103,2814,230],{},[103,2816,233],{},[113,2818,2819,2831,2843,2855,2867,2879,2891,2903,2915,2927],{},[100,2820,2821,2823,2825,2829],{},[118,2822,240],{},[118,2824,243],{},[118,2826,2827],{},[15,2828,248],{},[118,2830,251],{},[100,2832,2833,2835,2837,2841],{},[118,2834,256],{},[118,2836,259],{},[118,2838,2839],{},[15,2840,264],{},[118,2842,251],{},[100,2844,2845,2847,2849,2853],{},[118,2846,271],{},[118,2848,274],{},[118,2850,2851],{},[15,2852,279],{},[118,2854,282],{},[100,2856,2857,2859,2861,2865],{},[118,2858,287],{},[118,2860,290],{},[118,2862,2863],{},[15,2864,295],{},[118,2866,298],{},[100,2868,2869,2871,2873,2877],{},[118,2870,303],{},[118,2872,306],{},[118,2874,2875],{},[15,2876,311],{},[118,2878,314],{},[100,2880,2881,2883,2885,2889],{},[118,2882,319],{},[118,2884,322],{},[118,2886,2887],{},[15,2888,327],{},[118,2890,330],{},[100,2892,2893,2895,2897,2901],{},[118,2894,335],{},[118,2896,338],{},[118,2898,2899],{},[15,2900,343],{},[118,2902,346],{},[100,2904,2905,2907,2909,2913],{},[118,2906,351],{},[118,2908,354],{},[118,2910,2911],{},[15,2912,359],{},[118,2914,362],{},[100,2916,2917,2919,2921,2925],{},[118,2918,367],{},[118,2920,370],{},[118,2922,2923],{},[15,2924,375],{},[118,2926,378],{},[100,2928,2929,2931,2933,2937],{},[118,2930,383],{},[118,2932,386],{},[118,2934,2935],{},[15,2936,391],{},[118,2938,394],{},[20,2940,2941],{},[11,2942,2943,402],{},[15,2944,401],{},[41,2946],{},[44,2948,408],{"id":407},[11,2950,411],{},[49,2952,415],{"id":414},[62,2954,2955,2959,2963,2967,2971],{},[65,2956,420,2957,424],{},[15,2958,423],{},[65,2960,2961,430],{},[15,2962,429],{},[65,2964,2965,436],{},[15,2966,435],{},[65,2968,2969,442],{},[15,2970,441],{},[65,2972,2973,448],{},[15,2974,447],{},[49,2976,452],{"id":451},[62,2978,2979,2983,2987],{},[65,2980,2981,460],{},[15,2982,459],{},[65,2984,2985,466],{},[15,2986,465],{},[65,2988,469,2989,78],{},[15,2990,472],{},[49,2992,476],{"id":475},[62,2994,2995,2999,3003],{},[65,2996,2997,484],{},[15,2998,483],{},[65,3000,3001,490],{},[15,3002,489],{},[65,3004,493],{},[49,3006,497],{"id":496},[11,3008,500],{},[49,3010,504],{"id":503},[62,3012,3013,3017,3021],{},[65,3014,3015,512],{},[15,3016,511],{},[65,3018,3019,518],{},[15,3020,517],{},[65,3022,3023,524],{},[15,3024,523],{},[41,3026],{},[44,3028,530],{"id":529},[11,3030,533,3031,537],{},[15,3032,536],{},[11,3034,3035],{},[15,3036,542],{},[544,3038,3039,3041,3043],{},[65,3040,548],{},[65,3042,551],{},[65,3044,554],{},[11,3046,3047],{},[15,3048,559],{},[62,3050,3051,3053,3055,3057],{},[65,3052,564],{},[65,3054,567],{},[65,3056,570],{},[65,3058,573],{},[20,3060,3061,3067],{},[11,3062,3063,580,3065,584],{},[15,3064,60],{},[15,3066,583],{},[11,3068,3069,590],{},[15,3070,589],{},[41,3072],{},[44,3074,596],{"id":595},[11,3076,599],{},[62,3078,3079,3083,3087,3091],{},[65,3080,3081,607],{},[15,3082,606],{},[65,3084,3085,613],{},[15,3086,612],{},[65,3088,3089,619],{},[15,3090,618],{},[65,3092,3093,625],{},[15,3094,624],{},[41,3096],{},[44,3098,631],{"id":630},[94,3100,3101,3111],{},[97,3102,3103],{},[100,3104,3105,3107,3109],{},[103,3106,640],{},[103,3108,643],{},[103,3110,646],{},[113,3112,3113,3121,3129,3137,3145,3153,3161],{},[100,3114,3115,3117,3119],{},[118,3116,653],{},[118,3118,656],{},[118,3120,659],{},[100,3122,3123,3125,3127],{},[118,3124,664],{},[118,3126,667],{},[118,3128,670],{},[100,3130,3131,3133,3135],{},[118,3132,675],{},[118,3134,678],{},[118,3136,681],{},[100,3138,3139,3141,3143],{},[118,3140,686],{},[118,3142,678],{},[118,3144,691],{},[100,3146,3147,3149,3151],{},[118,3148,696],{},[118,3150,699],{},[118,3152,702],{},[100,3154,3155,3157,3159],{},[118,3156,707],{},[118,3158,710],{},[118,3160,713],{},[100,3162,3163,3165,3167],{},[118,3164,718],{},[118,3166,678],{},[118,3168,723],{},[41,3170],{},[44,3172,729],{"id":728},[62,3174,3176,3181,3186,3191,3196,3201,3206,3211,3216,3221],{"className":3175},[733],[65,3177,3179,743],{"className":3178},[737],[739,3180],{"disabled":741,"type":742},[65,3182,3184,749],{"className":3183},[737],[739,3185],{"disabled":741,"type":742},[65,3187,3189,755],{"className":3188},[737],[739,3190],{"disabled":741,"type":742},[65,3192,3194,761],{"className":3193},[737],[739,3195],{"disabled":741,"type":742},[65,3197,3199,767],{"className":3198},[737],[739,3200],{"disabled":741,"type":742},[65,3202,3204,773],{"className":3203},[737],[739,3205],{"disabled":741,"type":742},[65,3207,3209,779],{"className":3208},[737],[739,3210],{"disabled":741,"type":742},[65,3212,3214,785],{"className":3213},[737],[739,3215],{"disabled":741,"type":742},[65,3217,3219,791],{"className":3218},[737],[739,3220],{"disabled":741,"type":742},[65,3222,3224,797],{"className":3223},[737],[739,3225],{"disabled":741,"type":742},[44,3227,801],{"id":800},[11,3229,804],{},[11,3231,807],{},[11,3233,810],{},[44,3235,814],{"id":813},[11,3237,817],{},[11,3239,820],{},[44,3241,824],{"id":823},[62,3243,3244,3249],{},[65,3245,3246],{},[830,3247,835],{"href":832,"rel":3248},[834],[65,3250,838],{},[41,3252],{},[44,3254,844],{"id":843},[62,3256,3257,3261,3265],{},[65,3258,3259],{},[830,3260,852],{"href":851},[65,3262,3263],{},[830,3264,858],{"href":857},[65,3266,3267],{},[830,3268,864],{"href":863},[41,3270],{},[11,3272,3273],{},[29,3274,871,3275,875,3277],{},[15,3276,874],{},[830,3278,879],{"href":878},{"title":881,"searchDepth":882,"depth":882,"links":3280},[3281,3285,3286,3293,3294,3295,3296,3297,3298,3299,3300],{"id":46,"depth":882,"text":47,"children":3282},[3283,3284],{"id":51,"depth":887,"text":52},{"id":88,"depth":887,"text":89},{"id":207,"depth":882,"text":208},{"id":407,"depth":882,"text":408,"children":3287},[3288,3289,3290,3291,3292],{"id":414,"depth":887,"text":415},{"id":451,"depth":887,"text":452},{"id":475,"depth":887,"text":476},{"id":496,"depth":887,"text":497},{"id":503,"depth":887,"text":504},{"id":529,"depth":882,"text":530},{"id":595,"depth":882,"text":596},{"id":630,"depth":882,"text":631},{"id":728,"depth":882,"text":729},{"id":800,"depth":882,"text":801},{"id":813,"depth":882,"text":814},{"id":823,"depth":882,"text":824},{"id":843,"depth":882,"text":844},{},{"title":5,"description":907},[919,920,921,905,922,923,924],{"id":3305,"title":3306,"articleId":6,"body":3307,"category":905,"date":906,"description":4165,"extension":908,"lastUpdated":909,"locale":4166,"meta":4167,"navigation":741,"path":4168,"publishDate":906,"readTime":913,"refreshInterval":914,"seo":4169,"slug":4170,"stem":4171,"tags":4172,"__hash__":4178},"blog\u002Fblog\u002Fdraw-situation-plan.nl.md","Situatieschema tekenen: Stap-voor-stap handleiding volgens AREI",{"type":8,"value":3308,"toc":4141},[3309,3316,3332,3335,3337,3341,3345,3348,3353,3376,3380,3383,3476,3478,3482,3489,3657,3664,3666,3670,3673,3677,3709,3713,3733,3737,3754,3758,3761,3765,3785,3787,3791,3798,3803,3814,3819,3833,3850,3852,3856,3859,3884,3886,3890,3982,3984,3988,4051,4055,4058,4061,4064,4068,4071,4074,4078,4082,4085,4088,4091,4102,4104,4108,4128,4130],[11,3310,3311,3312,3315],{},"Het situatieschema (ook wel situatieplan of plan de situation) toont ",[15,3313,3314],{},"waar precies"," elk elektrisch onderdeel zich in uw gebouw bevindt. Voor een nieuwe huishoudelijke installatie en een belangrijke wijziging of uitbreiding wordt het samen met het eendraadschema opgesteld. Voor bestaande installaties en kleine wijzigingen gelden afgebakende regels; het erkende controleorganisme beoordeelt het concrete dossier.",[20,3317,3318],{},[11,3319,3320,3323,3324,3327,3328,3331],{},[15,3321,3322],{},"Kort uitgelegd:"," Terwijl het éénlijnschema de ",[29,3325,3326],{},"logische schakeling"," weergeeft (welke schakelaar bedient welk lichtpunt, via welk circuit), toont het situatieschema de ",[29,3329,3330],{},"fysieke positie"," van elk onderdeel op het grondplan.",[11,3333,3334],{},"Deze handleiding legt stap voor stap uit hoe u een controleerbaar situatieschema voorbereidt. Alleen een erkend controleorganisme kan besluiten of het volledige dossier en de uitgevoerde installatie aan de voorschriften voldoen.",[41,3336],{},[44,3338,3340],{"id":3339},"stap-1-grondplan-voorbereiden","Stap 1: Grondplan voorbereiden",[49,3342,3344],{"id":3343},"afmetingen-en-schaal","Afmetingen en schaal",[11,3346,3347],{},"Het grondplan vormt de basis van uw situatieschema. U kunt het overnemen van een bouwplan of zelf tekenen.",[11,3349,3350],{},[15,3351,3352],{},"Belangrijk:",[62,3354,3355,3362,3369],{},[65,3356,3357,3358,3361],{},"Gebruik een ",[15,3359,3360],{},"uniforme schaal"," (gebruikelijk: 1:50 of 1:100).",[65,3363,3364,3365,3368],{},"Teken alle ",[15,3366,3367],{},"muren, deuren en ramen"," in.",[65,3370,3371,3372,3375],{},"Markeer de ",[15,3373,3374],{},"openingsrichting"," van deuren (kwartcirkel) — dit beïnvloedt de schakelaarspositie.",[49,3377,3379],{"id":3378},"ruimtes-labelen","Ruimtes labelen",[11,3381,3382],{},"Voorzie elke ruimte van een benaming en idealiter het oppervlak:",[94,3384,3385,3398],{},[97,3386,3387],{},[100,3388,3389,3392,3395],{},[103,3390,3391],{},"Afkorting",[103,3393,3394],{},"Ruimte",[103,3396,3397],{},"Typisch oppervlak",[113,3399,3400,3410,3419,3429,3439,3448,3456,3466],{},[100,3401,3402,3405,3408],{},[118,3403,3404],{},"WK",[118,3406,3407],{},"Woonkamer",[118,3409,126],{},[100,3411,3412,3414,3417],{},[118,3413,1086],{},[118,3415,3416],{},"Keuken",[118,3418,137],{},[100,3420,3421,3424,3427],{},[118,3422,3423],{},"SK",[118,3425,3426],{},"Slaapkamer",[118,3428,148],{},[100,3430,3431,3434,3437],{},[118,3432,3433],{},"BK",[118,3435,3436],{},"Badkamer",[118,3438,159],{},[100,3440,3441,3443,3446],{},[118,3442,1945],{},[118,3444,3445],{},"Hal\u002FGang",[118,3447,170],{},[100,3449,3450,3452,3454],{},[118,3451,1077],{},[118,3453,178],{},[118,3455,181],{},[100,3457,3458,3461,3464],{},[118,3459,3460],{},"KL",[118,3462,3463],{},"Kelder",[118,3465,1092],{},[100,3467,3468,3471,3474],{},[118,3469,3470],{},"BU",[118,3472,3473],{},"Buitenzone",[118,3475,1092],{},[41,3477],{},[44,3479,3481],{"id":3480},"stap-2-arei-symbolen-gebruiken","Stap 2: AREI-symbolen gebruiken",[11,3483,3484,3485,3488],{},"AREI-",[15,3486,3487],{},"tabel 2.23"," geeft een niet-uitputtende lijst van symbolen. Staat voor een onderdeel geen symbool in de tabel, dan mag een ander eenduidig herkenbaar symbool worden gebruikt als de legende het definieert. Tien nuttige symboolgroepen voor het situatieschema zijn:",[94,3490,3491,3506],{},[97,3492,3493],{},[100,3494,3495,3497,3500,3503],{},[103,3496,1124],{},[103,3498,3499],{},"Symbool",[103,3501,3502],{},"Beschrijving",[103,3504,3505],{},"Gebruik",[113,3507,3508,3523,3537,3552,3567,3582,3597,3612,3627,3642],{},[100,3509,3510,3512,3515,3520],{},[118,3511,240],{},[118,3513,3514],{},"⏚ Halve cirkel",[118,3516,3517],{},[15,3518,3519],{},"Enkel stopcontact",[118,3521,3522],{},"Wandpositie markeren",[100,3524,3525,3527,3530,3535],{},[118,3526,256],{},[118,3528,3529],{},"⏚⏚ Dubbele halve cirkel",[118,3531,3532],{},[15,3533,3534],{},"Dubbel stopcontact",[118,3536,3522],{},[100,3538,3539,3541,3544,3549],{},[118,3540,271],{},[118,3542,3543],{},"○ met kruis",[118,3545,3546],{},[15,3547,3548],{},"Plafondlamp",[118,3550,3551],{},"Midden van de ruimte\u002Fpositie",[100,3553,3554,3556,3559,3564],{},[118,3555,287],{},[118,3557,3558],{},"─○ met streep",[118,3560,3561],{},[15,3562,3563],{},"Wandlamp",[118,3565,3566],{},"Aan de wand",[100,3568,3569,3571,3574,3579],{},[118,3570,303],{},[118,3572,3573],{},"Schakelaarsteken",[118,3575,3576],{},[15,3577,3578],{},"Enkelpolige schakelaar",[118,3580,3581],{},"Naast de deur (openingszijde)",[100,3583,3584,3586,3589,3594],{},[118,3585,319],{},[118,3587,3588],{},"Schakelaarsteken met 2 pijlen",[118,3590,3591],{},[15,3592,3593],{},"Serieschakelaar",[118,3595,3596],{},"Bedient 2 lichtpunten",[100,3598,3599,3601,3604,3609],{},[118,3600,335],{},[118,3602,3603],{},"Schakelaarsteken met lijn",[118,3605,3606],{},[15,3607,3608],{},"Wisselschakelaar",[118,3610,3611],{},"Twee plaatsen, één licht",[100,3613,3614,3616,3619,3624],{},[118,3615,351],{},[118,3617,3618],{},"Rechthoek met bliksem",[118,3620,3621],{},[15,3622,3623],{},"Verdeelkast",[118,3625,3626],{},"Meestal hal\u002Ftechnische ruimte",[100,3628,3629,3631,3634,3639],{},[118,3630,367],{},[118,3632,3633],{},"⏚ met PE",[118,3635,3636],{},[15,3637,3638],{},"Aardingsaansluiting",[118,3640,3641],{},"Aardingspunt",[100,3643,3644,3646,3649,3654],{},[118,3645,383],{},[118,3647,3648],{},"Cirkel met R",[118,3650,3651],{},[15,3652,3653],{},"Rookmelder",[118,3655,3656],{},"Elke slaapkamer, hal, trappenhuis",[20,3658,3659],{},[11,3660,3661,3663],{},[15,3662,2165],{}," Gebruik voor gangbare onderdelen de AREI-symbolen uit Tabel 2.23. Zijn afwijkende symbolen nodig, dan moeten die eenduidig zijn en in de legende worden toegelicht — niet-gedefinieerde of niet-toegelichte symbolen worden bij de keuring afgekeurd.",[41,3665],{},[44,3667,3669],{"id":3668},"stap-3-componenten-intekenen","Stap 3: Componenten intekenen",[11,3671,3672],{},"Nu plaatst u de symbolen op het grondplan. Volgende regels helpen bij de correcte positionering:",[49,3674,3676],{"id":3675},"stopcontacten","Stopcontacten",[62,3678,3679,3685,3691,3697,3703],{},[65,3680,3681,3684],{},[15,3682,3683],{},"Op de wand"," tekenen, op de werkelijke positie.",[65,3686,3687,3690],{},[15,3688,3689],{},"Keuken:"," Registreer echte werkstopcontacten en vaste toestellen apart; aantal en eigen kringen volgen uit gebruik en professioneel ontwerp.",[65,3692,3693,3696],{},[15,3694,3695],{},"Woonruimtes:"," Teken werkelijk geplande of aanwezige stopcontacten; het AREI legt geen algemeen aantal per oppervlakte op.",[65,3698,3699,3702],{},[15,3700,3701],{},"Badkamer:"," Laagspanningsstopcontacten pas vanaf zone 2 (alleen bij badkuipen; het stopcontact moet beveiligd zijn door een differentieelschakelaar met zeer hoge gevoeligheid ≤ 10 mA, of afzonderlijk door een scheidingstransformator met een maximaal vermogen van 100 W) of buiten de zones. Bij douches bestaat zone 2 niet (Art. 7.1.3.2 Nr. 3b, Art. 7.1.5.2d).",[65,3704,3705,3708],{},[15,3706,3707],{},"Buiten:"," Laat externe invloeden, vereiste IP-graad en toepasselijke 30 mA-beveiliging professioneel bepalen; een eigen RCD is geen algemene conclusie van het situatieschema.",[49,3710,3712],{"id":3711},"schakelaars","Schakelaars",[62,3714,3715,3721,3727],{},[65,3716,3717,3720],{},[15,3718,3719],{},"Naast de deur"," aan de openingszijde, ca. 105 cm hoogte (praktijkaanbeveling — het AREI schrijft geen specifieke schakelaarhoogte voor, maar vereist wel 'gemakkelijk bereikbaar').",[65,3722,3723,3726],{},[15,3724,3725],{},"Wisselschakelaars"," bij ruimtes met meerdere ingangen of aan het begin\u002Feinde van de trap.",[65,3728,3729,3730,78],{},"Verbind schakelaars en bijbehorende lichtpunten met een ",[15,3731,3732],{},"stippellijn",[49,3734,3736],{"id":3735},"verlichtingspunten","Verlichtingspunten",[62,3738,3739,3745,3751],{},[65,3740,3741,3744],{},[15,3742,3743],{},"Plafondlampen"," in het midden van de ruimte of op de geplande positie.",[65,3746,3747,3750],{},[15,3748,3749],{},"Wandlampen"," op de wandpositie.",[65,3752,3753],{},"Teken alle werkelijk geplande of aanwezige lichtpunten; het aantal volgt uit gebruik en ontwerp.",[49,3755,3757],{"id":3756},"regionale-brandveiligheidsinformatie","Regionale brandveiligheidsinformatie",[11,3759,3760],{},"Rookmelders kunnen als afzonderlijke gebouwlaag worden toegevoegd. Vereisten verschillen volgens regio en gebruik en worden tegen de huidige bevoegde officiële bron gecontroleerd. Ze zijn geen algemeen inhoudsveld van het AREI-situatieschema en blijven herkenbaar gescheiden van elektrische kringreferenties.",[49,3762,3764],{"id":3763},"speciale-verbruikers","Speciale verbruikers",[62,3766,3767,3773,3779],{},[65,3768,3769,3772],{},[15,3770,3771],{},"Laadpaal"," (elektrisch voertuig): garage of buitenmuur, eigen circuit.",[65,3774,3775,3778],{},[15,3776,3777],{},"Boiler\u002FDoorstromer:"," Eigen circuit, positie intekenen.",[65,3780,3781,3784],{},[15,3782,3783],{},"Warmtepomp\u002FAirco:"," Buitenunit + binnenunit markeren.",[41,3786],{},[44,3788,3790],{"id":3789},"stap-4-circuitnummers-toewijzen","Stap 4: Circuitnummers toewijzen",[11,3792,3793,3794,3797],{},"Elk onderdeel in het situatieschema krijgt ",[15,3795,3796],{},"hetzelfde circuitnummer"," als in het éénlijnschema. Dit is essentieel voor de toewijzing bij de keuring.",[11,3799,3800],{},[15,3801,3802],{},"Zo werkt het:",[544,3804,3805,3808,3811],{},[65,3806,3807],{},"Het AREI identificeert elementaire kringen met een hoofdletter (A, B, C, ...) en de afzonderlijke elementen (lichtpunt, stopcontact) met een volgnummer — bijv. \"A1, A2, ...\".",[65,3809,3810],{},"Schrijf deze aanduiding bij elk onderdeel in het situatieschema.",[65,3812,3813],{},"Een vereenvoudigde doorlopende nummering (bijv. \"K1\" of \"1\") is in de praktijk gangbaar, zolang het éénlijnschema en het situatieschema consistent blijven.",[11,3815,3816],{},[15,3817,3818],{},"Voorbeeld:",[62,3820,3821,3824,3827,3830],{},[65,3822,3823],{},"Circuit 1: Verlichting gelijkvloers → Alle lichtpunten op het gelijkvloers krijgen \"1\".",[65,3825,3826],{},"Circuit 2: Stopcontacten woonkamer → Alle WK-stopcontacten krijgen \"2\".",[65,3828,3829],{},"Circuit 3: Stopcontacten keuken → Alle KE-stopcontacten krijgen \"3\".",[65,3831,3832],{},"Circuit 4: Apart oven → Eén stopcontact met \"4\".",[20,3834,3835,3844],{},[11,3836,3837,3839,3840,3843],{},[15,3838,3352],{}," De nummers moeten tussen éénlijnschema en situatieschema ",[15,3841,3842],{},"exact overeenkomen",". Inconsistenties zijn een van de meest voorkomende redenen voor opmerkingen bij de keuring.",[11,3845,3846,3849],{},[15,3847,3848],{},"Documentatieplicht:"," Art. 9.1.2 Nr. 1 (éénlijnschema) en Art. 9.1.2 Nr. 2 (situatieschema\u002Flageplan).",[41,3851],{},[44,3853,3855],{"id":3854},"stap-5-legende-en-opschrift","Stap 5: Legende en opschrift",[11,3857,3858],{},"Vul uw plan aan met:",[62,3860,3861,3866,3872,3878],{},[65,3862,3863,3865],{},[15,3864,1492],{}," met alle gebruikte symbolen en hun betekenis.",[65,3867,3868,3871],{},[15,3869,3870],{},"Titelblok"," (cartouche) met: naam eigenaar, adres, datum, planmaker, schaal.",[65,3873,3874,3877],{},[15,3875,3876],{},"Noordpijl"," (optioneel, maar nuttig).",[65,3879,3880,3883],{},[15,3881,3882],{},"Verdiepingsaanduiding"," bij gebouwen met meerdere verdiepingen (één plan per verdieping).",[41,3885],{},[44,3887,3889],{"id":3888},"veelgemaakte-fouten","Veelgemaakte fouten",[94,3891,3892,3905],{},[97,3893,3894],{},[100,3895,3896,3899,3902],{},[103,3897,3898],{},"Fout",[103,3900,3901],{},"Gevolg",[103,3903,3904],{},"Oplossing",[113,3906,3907,3918,3929,3940,3950,3961,3972],{},[100,3908,3909,3912,3915],{},[118,3910,3911],{},"Regionale brandregels als AREI-regel voorstellen",[118,3913,3914],{},"Verkeerde keuringsbasis",[118,3916,3917],{},"Controleer apart tegen actuele regionale bron en label de laag",[100,3919,3920,3923,3926],{},[118,3921,3922],{},"Elk buitenstopcontact gelijk behandelen",[118,3924,3925],{},"Externe invloeden of bescherming kunnen fout zijn",[118,3927,3928],{},"Beoordeel IP-graad en 30 mA-beveiliging per project",[100,3930,3931,3934,3937],{},[118,3932,3933],{},"Ontbrekende opschriften \u002F circuitnummers",[118,3935,3936],{},"Opmerking",[118,3938,3939],{},"Elk onderdeel nummeren",[100,3941,3942,3945,3947],{},[118,3943,3944],{},"Niet-gedefinieerde\u002Fniet-toegelichte symbolen",[118,3946,3936],{},[118,3948,3949],{},"AREI-symbolen (Tabel 2.23) gebruiken; afwijkende symbolen eenduidig kiezen en in de legende toelichten",[100,3951,3952,3955,3958],{},[118,3953,3954],{},"Schakelaar aan verkeerde deurzijde",[118,3956,3957],{},"Onpraktisch (geen AREI-overtreding)",[118,3959,3960],{},"Openingsrichting controleren",[100,3962,3963,3966,3969],{},[118,3964,3965],{},"Badkamerstopcontact in een verkeerde zone weergegeven",[118,3967,3968],{},"Plan en uitvoering kunnen een veiligheidsbevinding opleveren",[118,3970,3971],{},"Laat zones en bescherming volgens huidig hoofdstuk 7.1 professioneel controleren",[100,3973,3974,3977,3979],{},[118,3975,3976],{},"Geen legende",[118,3978,3936],{},[118,3980,3981],{},"Symbooltabel bijvoegen",[41,3983],{},[44,3985,3987],{"id":3986},"checklist-voor-indiening","Checklist voor indiening",[62,3989,3991,3997,4003,4009,4015,4021,4027,4033,4039,4045],{"className":3990},[733],[65,3992,3994,3996],{"className":3993},[737],[739,3995],{"disabled":741,"type":742}," Alle ruimtes gelabeld",[65,3998,4000,4002],{"className":3999},[737],[739,4001],{"disabled":741,"type":742}," Alle stopcontacten, schakelaars, lichtpunten ingetekend",[65,4004,4006,4008],{"className":4005},[737],[739,4007],{"disabled":741,"type":742}," Regionale brandveiligheidsinformatie, indien getoond, apart gecontroleerd en gelabeld",[65,4010,4012,4014],{"className":4011},[737],[739,4013],{"disabled":741,"type":742}," Buitenstopcontacten vastgelegd met projectspecifieke IP- en beveiligingsbeoordeling",[65,4016,4018,4020],{"className":4017},[737],[739,4019],{"disabled":741,"type":742}," Circuitnummers bij elk onderdeel",[65,4022,4024,4026],{"className":4023},[737],[739,4025],{"disabled":741,"type":742}," Nummers komen overeen met éénlijnschema",[65,4028,4030,4032],{"className":4029},[737],[739,4031],{"disabled":741,"type":742}," AREI-symbolen gebruikt (Tabel 2.23)",[65,4034,4036,4038],{"className":4035},[737],[739,4037],{"disabled":741,"type":742}," Legende aanwezig",[65,4040,4042,4044],{"className":4041},[737],[739,4043],{"disabled":741,"type":742}," Titelblok met naam, adres, datum",[65,4046,4048,4050],{"className":4047},[737],[739,4049],{"disabled":741,"type":742}," Eén plan per verdieping",[44,4052,4054],{"id":4053},"loop-het-plan-na-in-het-gebouw","Loop het plan na in het gebouw",[11,4056,4057],{},"Neem de tekening mee door het gebouw. Start bij de verdeelkast en volg elke kring. Controleer niet alleen of er een stopcontact staat, maar onderscheid meervoudig of geschakeld stopcontact, verbindingsdoos, vaste aansluiting en lichtpunt. Een schakelaarreferentie moet tonen welk lichtpunt of toestel wordt bediend. Punten achter vast meubilair, buitenpunten, technische ruimten en bijgebouwen worden vaak vergeten.",[11,4059,4060],{},"Vergelijk daarna het eendraadschema. A3 op het situatieschema moet hetzelfde element A3 in kring A zijn. Dubbele referenties, overgeslagen nummers en na de opname verplaatste toestellen veroorzaken tegenstrijdige documenten. Gebruik bij meerdere verdiepingen of gebouwen een heldere bladstructuur en behoud nummer, versie en versiedatum op elk uitgereikt plan.",[11,4062,4063],{},"Het situatieschema beschrijft de werkelijke installatie, niet alleen het ontwerp. Rond een wijziging pas af nadat ligging en positie ter plaatse zijn gecontroleerd. Bij een niet-belangrijke huishoudelijke wijziging kan Boek 1 een korte beschrijving toestaan in plaats van een nieuw eendraadschema; de wijziging of uitbreiding blijft wel op het situatieschema staan. Belangrijke wijzigingen of uitbreidingen vragen bijgewerkte plannen en een controle van de betrokken werken vóór ingebruikname.",[44,4065,4067],{"id":4066},"wat-een-symbool-niet-bewijst","Wat een symbool niet bewijst",[11,4069,4070],{},"Een symbool bewijst geen montagehoogte, beschermingsgraad, badkamerzone, aardingskwaliteit of uitschakeltijd. Daarvoor zijn plaatsbezoek, metingen en soms fabrikantdocumenten nodig. Rookmelderplichten komen bovendien uit regionale bouw- en woonregels en mogen niet als algemene AREI-planplicht worden voorgesteld. Ze kunnen nuttige gebouwinformatie zijn zonder de elektrische keuringsvraag te vervangen.",[11,4072,4073],{},"PlanElec koppelt toestelpositie en elektrische toewijzing in één projectmodel, maar elk voorstel moet worden nagekeken. Een niet-geplaatst toestel, een toestel zonder kring of een object dat alleen in een referentiebeeld staat, is niet afgewerkt. De zelfcontrole is indicatief en beperkt tot ondersteunde regels; het officiële oordeel ligt bij een erkend controleorganisme.",[44,4075,4077],{"id":4076},"officiële-bron","Officiële bron",[49,4079,4081],{"id":4080},"leesbaarheid-in-de-uitgave","Leesbaarheid in de uitgave",[11,4083,4084],{},"Exporteer het plan eenmaal op de bedoelde papiergrootte. Symbolen, referenties en ruimtegrenzen moeten zonder extreem zoomen leesbaar blijven. Verplaats overlappende labels met een duidelijke verwijslijn. Kleur mag helpen tijdens bewerking, maar kan niet de enige betekenis dragen omdat een keuringskopie zwart-wit kan zijn.",[11,4086,4087],{},"Houd een lijst bij van ontoegankelijke dozen, onbekende schakelrelaties en vermoedelijke trajecten. Los ze vóór de eindversie op of toon ze eerlijk als onbekend. Een gemarkeerde lacune is beter dan een symbool op een gegokte plaats. Laat ten slotte iemand anders enkele referenties tussen situatieschema, eendraadschema en kastlabel volgen.",[11,4089,4090],{},"Controleer ook dat vaste toestellen, bronnen en verdeelkasten niet verdwijnen achter algemene ruimtetekst. Een verwijslijn moet naar precies één object leiden. Bewaar bij correcties de vorige vrijgegeven versie, zodat duidelijk blijft welke ruimtelijke toestand eerder werd gecontroleerd.",[62,4092,4093,4099],{},[65,4094,4095],{},[830,4096,4098],{"href":832,"rel":4097},[834],"FOD Economie: huidige officiële AREI\u002FRGIE-publicatie van Boek 1",[65,4100,4101],{},"Afdeling 3.1.2 en tabel 2.23 vormen de basis. Als tabel 2.23 geen symbool bevat, mag een ander ondubbelzinnig symbool met uitleg in de legende worden gebruikt.",[41,4103],{},[44,4105,4107],{"id":4106},"gerelateerde-artikelen","Gerelateerde artikelen",[62,4109,4110,4116,4122],{},[65,4111,4112],{},[830,4113,4115],{"href":4114},"\u002Fblog\u002Feendraadschema-maken","Een eendraadschema maken in België",[65,4117,4118],{},[830,4119,4121],{"href":4120},"\u002Fblog\u002Felektrische-keuring","Elektrische keuring in België",[65,4123,4124],{},[830,4125,4127],{"href":4126},"\u002Fblog\u002Fverdeelkast-plannen-opbouw","Verdeelkast plannen: Opbouw en dimensionering",[41,4129],{},[11,4131,4132],{},[29,4133,4134,4135,4137,4138],{},"Met ",[15,4136,874],{}," maakt u uw situatieschema rechtstreeks vanuit het grondplan — ruimtes tekenen, apparaten slepen en neerzetten, AREI-symbolen worden automatisch gebruikt. ",[830,4139,4140],{"href":878},"Nu gratis uitproberen →",{"title":881,"searchDepth":882,"depth":882,"links":4142},[4143,4147,4148,4155,4156,4157,4158,4159,4160,4161,4164],{"id":3339,"depth":882,"text":3340,"children":4144},[4145,4146],{"id":3343,"depth":887,"text":3344},{"id":3378,"depth":887,"text":3379},{"id":3480,"depth":882,"text":3481},{"id":3668,"depth":882,"text":3669,"children":4149},[4150,4151,4152,4153,4154],{"id":3675,"depth":887,"text":3676},{"id":3711,"depth":887,"text":3712},{"id":3735,"depth":887,"text":3736},{"id":3756,"depth":887,"text":3757},{"id":3763,"depth":887,"text":3764},{"id":3789,"depth":882,"text":3790},{"id":3854,"depth":882,"text":3855},{"id":3888,"depth":882,"text":3889},{"id":3986,"depth":882,"text":3987},{"id":4053,"depth":882,"text":4054},{"id":4066,"depth":882,"text":4067},{"id":4076,"depth":882,"text":4077,"children":4162},[4163],{"id":4080,"depth":887,"text":4081},{"id":4106,"depth":882,"text":4107},"Volledige handleiding voor een controleerbaar situatieschema: van grondplan en AREI-symbolen tot kringreferenties en vakcontrole.","nl",{},"\u002Fblog\u002Fdraw-situation-plan.nl",{"title":3306,"description":4165},"situatieschema-tekenen-handleiding","blog\u002Fdraw-situation-plan.nl",[4173,1799,4174,4175,4176,1803,4177],"situatieschema","symbolen","handleiding","tekenen","grondplan","NqYsof0FX5rllS44cADWLeuZnMxcB4xvbMhzVF732bs",1788389241582]