[{"data":1,"prerenderedAt":23219},["ShallowReactive",2],{"blog-teaser-fr":3},[4,1251,2005,3322,4431,5002,5445,5874,6258,6624,7000,7394,7934,8425,8834,9286,9650,10097,10268,10580,10784,11133,11822,12271,12536,12921,13196,13880,14143,14552,15579,16439,17702,18552,18846,19185,19379,19701,20158,20421,20674,20870,21253,21499,21700,22104,22477,22996],{"id":5,"title":6,"articleId":7,"body":8,"category":1228,"date":1229,"description":1230,"extension":1231,"lastUpdated":1229,"locale":1232,"meta":1233,"navigation":1234,"path":1235,"publishDate":1229,"readTime":1236,"refreshInterval":1237,"seo":1238,"slug":1239,"stem":1240,"tags":1241,"__hash__":1250},"blog\u002Fblog\u002Fbill-of-materials-electrical.fr.md","Liste de matériel d’une installation électrique : quels postes doit-elle contenir ?","bill-of-materials-electrical",{"type":9,"value":10,"toc":1211},"minimark",[11,16,20,196,199,213,217,236,247,250,254,261,272,393,408,412,415,554,557,569,573,576,707,710,740,747,751,754,757,796,802,806,813,816,846,856,860,867,870,904,915,919,922,925,928,943,952,956,1016,1020,1035,1038,1076,1079,1090,1097,1124,1128,1135,1170,1174,1200,1206],[12,13,15],"h2",{"id":14},"quels-postes-doit-contenir-la-liste-de-matériel-dune-installation-électrique","Quels postes doit contenir la liste de matériel d’une installation électrique ?",[17,18,19],"p",{},"Sept groupes : tableau, appareils de protection, canalisations, boîtes, interrupteurs et prises, mise à la terre, petit matériel. Une liste n’est pas complète parce que les sept intitulés y figurent, mais parce que chaque poste a une origine traçable — un nombre issu du plan, une règle du RGIE ou une hypothèse explicitement énoncée par votre entreprise. Sans cette origine, la quantité n’est pas vérifiable et, à la version suivante du plan, elle n’est plus corrigeable.",[21,22,23,42],"table",{},[24,25,26],"thead",{},[27,28,29,33,36,39],"tr",{},[30,31,32],"th",{},"Groupe de postes",[30,34,35],{},"Postes individuels typiques",[30,37,38],{},"La quantité découle de",[30,40,41],{},"Ancrage normatif",[43,44,45,67,89,107,128,147,175],"tbody",{},[27,46,47,51,54,57],{},[48,49,50],"td",{},"Tableau",[48,52,53],{},"Coffret avec paroi arrière et porte, rangées et rails, plastrons, peignes, embouts, bornes d’alimentation, repérage",[48,55,56],{},"Nombre de modules par rangée, séparation par tarif",[48,58,59,63,64],{},[60,61,62],"em",{},"5.3.5.1. points a. et c.",", ",[60,65,66],{},"3.1.3.1.",[27,68,69,72,75,78],{},[48,70,71],{},"Appareils de protection",[48,73,74],{},"Interrupteur-sectionneur général, dispositifs différentiels 300 mA et 30 mA, disjoncteurs, éventuellement parafoudre",[48,76,77],{},"Nombre de circuits terminaux et leur répartition entre les différentiels",[48,79,80,63,83,63,86],{},[60,81,82],{},"5.3.5.1. point b.",[60,84,85],{},"4.2.4.3. point b.",[60,87,88],{},"5.2.1.2.",[27,90,91,94,97,100],{},[48,92,93],{},"Canalisations",[48,95,96],{},"Câble par type, nombre de conducteurs et section, en mètres ; tubes, tube préfilé, câble enterré",[48,98,99],{},"Cheminement par circuit, plus la marge",[48,101,102,63,105],{},[60,103,104],{},"3.1.2.2. point a.",[60,106,88],{},[27,108,109,112,115,118],{},[48,110,111],{},"Boîtes",[48,113,114],{},"Boîtes de connexion et de dérivation, boîtes d’encastrement pour maçonnerie ou cloison creuse, boîtes de sortie plafond et mur, boîtes de tirage",[48,116,117],{},"Nombre d’appareils plus nombre de points de dérivation",[48,119,120,63,122,63,125],{},[60,121,104],{},[60,123,124],{},"5.2.6.1.",[60,126,127],{},"5.3.5.2. point a.",[27,129,130,133,136,139],{},[48,131,132],{},"Interrupteurs et prises",[48,134,135],{},"Mécanismes, touches et enjoliveurs, plaques de finition par combinaison, variantes étanches avec joint",[48,137,138],{},"Nombre de points de commande et de prises au plan de position",[48,140,141,63,144],{},[60,142,143],{},"3.1.2.3. point a.",[60,145,146],{},"5.3.5.2. points a. et b.",[27,148,149,152,155,158],{},[48,150,151],{},"Mise à la terre",[48,153,154],{},"Boucle de terre, conducteur de terre, sectionneur de terre, conducteur principal d’équipotentialité, conducteurs supplémentaires, bornes de raccordement",[48,156,157],{},"Périmètre du bâtiment, nombre d’éléments conducteurs étrangers, salles de bains",[48,159,160,63,163,63,166,63,169,63,172],{},[60,161,162],{},"5.4.2.1.",[60,164,165],{},"5.4.2.2.",[60,167,168],{},"5.4.3.5.",[60,170,171],{},"5.4.4.1.",[60,173,174],{},"5.4.4.2.",[27,176,177,180,183,186],{},[48,178,179],{},"Petit matériel",[48,181,182],{},"Moyens de fixation et colliers, bornes, serre-câbles, couvercles, matériel de repérage, joints",[48,184,185],{},"Ratio par poste — convention d’entreprise",[48,187,188,63,191,63,194],{},[60,189,190],{},"5.2.9.5.",[60,192,193],{},"5.2.6.2. point b.",[60,195,66],{},[17,197,198],{},"La dernière ligne est marquée différemment à dessein : pour le petit matériel, le RGIE ne fixe aucune quantité. Il fixe des conditions dont les postes découlent — voir plus loin.",[17,200,201,202,207,208,212],{},"Cet article ne contient aucun prix. Non par prudence, mais parce qu’une fourchette de prix sans source nommée ni date est fausse au bout d’un trimestre et continue pourtant d’être citée. Pour le volet coûts : ",[203,204,206],"a",{"href":205},"\u002Ffr\u002Fblog\u002Fcout-plan-electrique","Combien coûte un plan électrique ?"," et ",[203,209,211],{"href":210},"\u002Ffr\u002Fblog\u002Fcomparatif-cout-soi-meme-vs-electricien","Comparatif de coût : dessiner soi-même ou faire appel à un électricien",".",[12,214,216],{"id":215},"la-liste-de-matériel-est-elle-obligatoire-selon-le-rgie","La liste de matériel est-elle obligatoire selon le RGIE ?",[17,218,219,220,224,225,228,229,232,233,212],{},"Non. Le RGIE ne connaît la liste de matériel que comme ",[221,222,223],"strong",{},"annexe autorisée"," au dossier : « Les schémas, plans et documents peuvent être complétés par des documents reprenant de façon plus détaillée les différentes caractéristiques du matériel électrique et\u002Fou des produits » (",[60,226,227],{},"sous-section 3.1.2.1. point c.","). Le verbe est ",[60,230,231],{},"peuvent",", pas ",[60,234,235],{},"doivent",[17,237,238,239,242,243,246],{},"Sont obligatoires, pour toute nouvelle installation domestique, le schéma unifilaire et le plan de position, établis par le responsable de l’exécution des travaux (",[60,240,241],{},"sous-section 3.1.2.1. point a.","). Si vous joignez la liste de matériel en annexe, elle suit le régime des annexes : elle est actualisée et tenue sur place à la disposition de toute personne autorisée à surveiller, contrôler, entretenir, réparer ou transformer l’installation (",[60,244,245],{},"sous-section 3.1.2.1. point d.",").",[17,248,249],{},"Conséquence pratique : la liste de matériel est un outil de chiffrage et d’approvisionnement, pas un document de contrôle. L’organisme agréé ne relève pas son absence. Il relève en revanche la présence de matériel qui n’a rien à faire là — et c’est précisément ce qu’une liste propre prévient, puisqu’elle fige le choix en amont.",[12,251,253],{"id":252},"quelles-données-le-plan-doit-il-porter-pour-que-les-quantités-soient-justes","Quelles données le plan doit-il porter pour que les quantités soient justes ?",[17,255,256,257,260],{},"Le schéma unifilaire fournit presque toute la liste des postes, mais pas la quantité la plus importante. La ",[60,258,259],{},"sous-section 3.1.2.2. point a."," exige au minimum : le type, la section et le nombre de conducteurs de chaque canalisation, le mode de pose, le type et les caractéristiques des dispositifs de protection à courant différentiel-résiduel, le type et les caractéristiques des dispositifs de protection contre les surintensités, les interrupteurs, les boîtes de connexion, les boîtes de dérivation, les socles de prise de courant, les points lumineux, les machines et appareils fixes et les sources.",[17,262,263,264,267,268,271],{},"L’énumération est remarquablement complète — et elle ne comporte ",[221,265,266],{},"aucune longueur",". La longueur des canalisations n’est exigée que pour les installations non domestiques (",[60,269,270],{},"sous-section 3.1.2.2. point b.","). Dans le logement, la donnée d’entrée déterminante du métré de câble ne figure donc dans aucun document obligatoire.",[21,273,274,287],{},[24,275,276],{},[27,277,278,281,284],{},[30,279,280],{},"Quantité dans la liste",[30,282,283],{},"Donnée d’entrée",[30,285,286],{},"Figure dans un document obligatoire ?",[43,288,289,307,321,333,345,357,372,383],{},[27,290,291,294,297],{},[48,292,293],{},"Nombre de prises",[48,295,296],{},"Socles de prise au schéma et au plan de position",[48,298,299,300,63,303,306],{},"oui (",[60,301,302],{},"3.1.2.2. a.",[60,304,305],{},"3.1.2.3. a.",")",[27,308,309,312,315],{},[48,310,311],{},"Nombre d’interrupteurs",[48,313,314],{},"Interrupteurs au schéma, leur position au plan",[48,316,299,317,63,319,306],{},[60,318,302],{},[60,320,305],{},[27,322,323,326,329],{},[48,324,325],{},"Nombre de boîtes",[48,327,328],{},"Boîtes de connexion et de dérivation au schéma",[48,330,299,331,306],{},[60,332,302],{},[27,334,335,338,341],{},[48,336,337],{},"Nombre de disjoncteurs",[48,339,340],{},"Nombre de circuits terminaux",[48,342,299,343,306],{},[60,344,302],{},[27,346,347,350,353],{},[48,348,349],{},"Type de câble et section",[48,351,352],{},"Type, section, nombre de conducteurs par canalisation",[48,354,299,355,306],{},[60,356,302],{},[27,358,359,364,367],{},[48,360,361],{},[221,362,363],{},"Longueur de câble en m",[48,365,366],{},"Cheminement le long des murs, gabarits, niveaux",[48,368,369],{},[221,370,371],{},"non — uniquement pour les installations non domestiques",[27,373,374,377,380],{},[48,375,376],{},"Matériel de terre",[48,378,379],{},"Périmètre du bâtiment, nombre d’éléments conducteurs étrangers",[48,381,382],{},"non — découle du chapitre 5.4, pas du schéma",[27,384,385,387,390],{},[48,386,179],{},[48,388,389],{},"Mode de pose, entraxes de fixation, mode de raccordement",[48,391,392],{},"non — convention d’entreprise",[17,394,395,396,399,400,403,404,212],{},"Le plan de position porte la ",[221,397,398],{},"position"," de ce même matériel, ni son nombre ni sa longueur (",[60,401,402],{},"sous-section 3.1.2.3. point a.","). Le métré de câble n’en découle qu’une fois un tracé dessiné ; la méthode est développée dans ",[203,405,407],{"href":406},"\u002Ffr\u002Fblog\u002Fcheminements-et-longueurs-de-cables","Cheminements et longueurs de câbles",[12,409,411],{"id":410},"combien-dappareils-de-protection-faut-il-et-doù-vient-ce-nombre","Combien d’appareils de protection faut-il — et d’où vient ce nombre ?",[17,413,414],{},"Pas de l’expérience, mais de quatre règles qui fixent ensemble le nombre de modules au tableau. C’est la partie de la liste de matériel que le RGIE pilote le plus directement.",[21,416,417,430],{},[24,418,419],{},[27,420,421,424,427],{},[30,422,423],{},"Règle",[30,425,426],{},"Référence",[30,428,429],{},"Effet sur la quantité",[43,431,432,444,456,468,484,500,516,528,541],{},[27,433,434,437,441],{},[48,435,436],{},"Tableau principal équipé d’un interrupteur-sectionneur général ; en domestique, pas moins de 40 A",[48,438,439],{},[60,440,82],{},[48,442,443],{},"1 poste, intensité assignée au moins égale à 40 A",[27,445,446,449,453],{},[48,447,448],{},"À l’origine de l’installation, au moins un dispositif différentiel de 300 mA au plus, assurant le sectionnement",[48,450,451],{},[60,452,85],{},[48,454,455],{},"au moins 1 poste 300 mA",[27,457,458,461,465],{},[48,459,460],{},"Immédiatement en aval, au moins un dispositif à haute ou très haute sensibilité, auquel sont raccordés prises, éclairage, salle de bains, lave-linge, sèche-linge et lave-vaisselle",[48,462,463],{},[60,464,85],{},[48,466,467],{},"au moins 1 poste 30 mA",[27,469,470,477,481],{},[48,471,472,473,476],{},"Au maximum ",[221,474,475],{},"huit circuits terminaux"," par dispositif différentiel de ce type",[48,478,479],{},[60,480,85],{},[48,482,483],{},"à partir du neuvième circuit concerné, un différentiel 30 mA supplémentaire",[27,485,486,492,497],{},[48,487,472,488,491],{},[221,489,490],{},"huit socles de prise"," par circuit terminal",[48,493,494],{},[60,495,496],{},"5.3.5.2. point b.",[48,498,499],{},"à partir de la neuvième prise, un circuit de plus avec disjoncteur et câble",[27,501,502,509,513],{},[48,503,504,505,508],{},"Au moins ",[221,506,507],{},"deux circuits d’éclairage distincts"," au-delà de deux locaux",[48,510,511],{},[60,512,496],{},[48,514,515],{},"minimum 2 circuits d’éclairage",[27,517,518,521,525],{},[48,519,520],{},"Circuit distinct par appareil de 2600 W ou plus, ainsi que pour lave-linge, lave-vaisselle, sèche-linge, cuisinière, plaque de cuisson et four électriques",[48,522,523],{},[60,524,88],{},[48,526,527],{},"1 circuit, 1 protection et 1 câble par appareil cité",[27,529,530,533,538],{},[48,531,532],{},"Dispositifs différentiels au moins de type A en domestique ; à l’origine, courant nominal d’au moins 40 A",[48,534,535],{},[60,536,537],{},"5.3.5.3. point a.",[48,539,540],{},"exclut le type AC et impose un calibre plancher",[27,542,543,546,551],{},[48,544,545],{},"Appareils de protection et de manœuvre de tarifs différents sur des panneaux distincts écartés d’au moins 10 cm, ou dans des tableaux distincts",[48,547,548],{},[60,549,550],{},"5.3.5.1. point c.",[48,552,553],{},"agrandit le coffret ou en impose un second",[17,555,556],{},"Cette chaîne explique pourquoi une liste de matériel construite à partir d’un comptage par local est presque toujours trop courte : le nombre de prises ne détermine pas seulement les postes « prise », mais aussi, par la règle des huit, le nombre de circuits, donc le nombre de disjoncteurs, le nombre de câbles et in fine le calibre du coffret.",[17,558,559,560,564,565,212],{},"Le détail des appareils exigeant un circuit propre figure dans ",[203,561,563],{"href":562},"\u002Ffr\u002Fblog\u002Fcircuit-dedie-obligatoire-appareils","Quels appareils exigent un circuit dédié"," ; la composition du tableau dans ",[203,566,568],{"href":567},"\u002Ffr\u002Fblog\u002Fplanifier-tableau-electrique","Planifier un tableau électrique",[12,570,572],{"id":571},"quel-matériel-de-mise-à-la-terre-est-systématiquement-oublié","Quel matériel de mise à la terre est systématiquement oublié ?",[17,574,575],{},"L’essentiel. La terre apparaît au schéma unifilaire sous forme d’un symbole, mais dans la liste de matériel sous forme de six à dix postes assortis de sections minimales imposées. Ces sections sont des chiffres du règlement, pas du catalogue.",[21,577,578,590],{},[24,579,580],{},[27,581,582,585,588],{},[30,583,584],{},"Poste",[30,586,587],{},"Minimum imposé",[30,589,426],{},[43,591,592,605,618,631,644,657,669,681,694],{},[27,593,594,597,600],{},[48,595,596],{},"Boucle de terre en fondation",[48,598,599],{},"au moins 35 mm² de section géométrique, conducteur plein ou 7 âmes câblées, sans soudure",[48,601,602],{},[60,603,604],{},"5.4.2.1. points b.1.3. et b.1.2.",[27,606,607,610,613],{},[48,608,609],{},"Métal de la boucle",[48,611,612],{},"cuivre électrolytique recuit nu ou cuivre plombé",[48,614,615],{},[60,616,617],{},"5.4.2.1. point b.1.4.",[27,619,620,623,626],{},[48,621,622],{},"Fixation de la boucle",[48,624,625],{},"uniquement cuivre ou matière sans action corrosive",[48,627,628],{},[60,629,630],{},"5.4.2.1. point b.1.5.",[27,632,633,636,639],{},[48,634,635],{},"Prise de terre complémentaire horizontale",[48,637,638],{},"au moins 35 mm², profondeur d’au moins 0,80 m, longueur minimale 15 m",[48,640,641],{},[60,642,643],{},"5.4.2.1. point b.3.",[27,645,646,649,652],{},[48,647,648],{},"Prise de terre complémentaire, barre ou piquet",[48,650,651],{},"longueur minimale 1,50 m, dont au moins 1,50 m enfoncé sous le niveau −0,60 m",[48,653,654],{},[60,655,656],{},"5.4.2.1. point b.4.1.",[27,658,659,662,665],{},[48,660,661],{},"Conducteur de terre",[48,663,664],{},"16 mm² cuivre avec revêtement anticorrosion, sinon 25 mm² cuivre, 50 mm² en aluminium ou acier",[48,666,667],{},[60,668,165],{},[27,670,671,674,677],{},[48,672,673],{},"Sectionneur de terre",[48,675,676],{},"dispositif de coupure démontable uniquement à l’aide d’un outil",[48,678,679],{},[60,680,168],{},[27,682,683,686,689],{},[48,684,685],{},"Conducteur principal d’équipotentialité",[48,687,688],{},"moitié de la section du plus gros conducteur de protection, minimum 6 mm² cuivre, limitation à 25 mm² admise",[48,690,691],{},[60,692,693],{},"5.4.4.1. point a.",[27,695,696,699,702],{},[48,697,698],{},"Conducteurs supplémentaires d’équipotentialité",[48,700,701],{},"au moins 2,5 mm² si protégés mécaniquement, 4 mm² sinon",[48,703,704],{},[60,705,706],{},"5.4.4.2. point a.",[17,708,709],{},"Trois points absents des chiffrages :",[711,712,713,724,734],"ul",{},[714,715,716,719,720,723],"li",{},[221,717,718],{},"La boucle de terre est du matériel de chantier, pas du matériel électrique."," Elle est exigée pour tout nouveau bâtiment dont le fond de fouille atteint au moins 60 cm (",[60,721,722],{},"5.4.2.1. point b.1.1.","), et elle est posée bien avant que quiconque ne pense aux prises. Établir la liste électrique après le gros œuvre revient à perdre ce poste de vue par construction.",[714,725,726,729,730,733],{},[221,727,728],{},"Les extrémités restent visitables"," (",[60,731,732],{},"5.4.2.1. point b.1.6.","). C’est une exigence d’exécution avec conséquence matérielle : regard, couvercle, repérage.",[714,735,736,739],{},[221,737,738],{},"La liaison équipotentielle principale n’est pas une borne unique",", mais un conducteur par élément conducteur étranger — eau, gaz, chauffage — avec une borne de raccordement sur la conduite concernée. La quantité découle des techniques spéciales, pas du plan électrique.",[17,741,742,743,212],{},"Le régime de neutre applicable est traité dans ",[203,744,746],{"href":745},"\u002Ffr\u002Fblog\u002Fmise-a-la-terre-tt-tns-belgique","Mise à la terre TT ou TN-S",[12,748,750],{"id":749},"pourquoi-les-boîtes-de-dérivation-et-dencastrement-manquent-elles-si-souvent","Pourquoi les boîtes de dérivation et d’encastrement manquent-elles si souvent ?",[17,752,753],{},"Parce que mentalement elles appartiennent au câble et, au catalogue, aux accessoires — alors que le RGIE les nomme explicitement comme éléments à part entière.",[17,755,756],{},"Quatre règles les rendent incontournables :",[711,758,759,769,778,787],{},[714,760,761,764,765,768],{},[221,762,763],{},"Les connexions ne peuvent se trouver qu’à certains endroits :"," dans les tableaux de répartition et de manœuvre, dans des boîtes de connexion ou de dérivation, aux bornes d’interrupteurs ou de socles de prise, ou dans des boîtes de plafond suffisamment grandes auxquelles sont suspendus les luminaires (",[60,766,767],{},"sous-section 5.2.6.1.","). Chaque dérivation au plan est donc un poste de matériel.",[714,770,771,729,774,777],{},[221,772,773],{},"Les connexions dans les tubes sont interdites",[60,775,776],{},"sous-section 5.2.9.3. point f.","). Un tracé dessiné sans boîte est un tracé non conforme.",[714,779,780,729,783,786],{},[221,781,782],{},"Dans les boîtes de connexion, de dérivation et de tirage, les conducteurs restent accessibles ; les tés et coudes sont interdits",[60,784,785],{},"sous-section 5.2.9.3. point i.2.","). Cela exclut la boîte la plus petite possible et se répercute sur le calibre, donc sur le prix.",[714,788,789,729,792,795],{},[221,790,791],{},"Les socles de prise encastrés dans les parois sont logés dans des boîtes métalliques ou en matière isolante",[60,793,794],{},"sous-section 5.3.5.2. point a.","). La boîte d’encastrement n’est donc pas une option mais du matériel obligatoire — une par point encastré, et d’un type différent en cloison creuse et en maçonnerie.",[17,797,798,799,801],{},"S’y ajoute que les boîtes de connexion et de dérivation font partie du contenu obligatoire du schéma unifilaire (",[60,800,259],{},"). Un schéma qui les omet est incomplet — et une liste de matériel dérivée d’un tel schéma l’est également.",[12,803,805],{"id":804},"quelle-réserve-de-câble-faut-il-prévoir","Quelle réserve de câble faut-il prévoir ?",[17,807,808,809,812],{},"Sur la ",[221,810,811],{},"valeur"," de la marge, le RGIE ne dit rien — ni pourcentage, ni longueur de réserve, ni facteur de chute. Tout chiffre que vous utilisez est une convention d’entreprise et doit figurer comme telle dans la feuille de calcul.",[17,814,815],{},"Ce que le règlement fixe, ce sont les conditions dont une réserve découle :",[711,817,818,824,830,840],{},[714,819,820,821,246],{},"Les raccordements aux appareils ne peuvent être soumis à des efforts de traction ou de torsion (",[60,822,823],{},"sous-section 5.2.6.2. point b.",[714,825,826,827,246],{},"Dans les portions verticales, les efforts de traction dus au poids propre ne peuvent s’exercer sur les bornes de raccordement (",[60,828,829],{},"sous-section 5.2.9.5.",[714,831,832,833,836,837,246],{},"Dans les tubes, il doit rester possible ",[221,834,835],{},"à tout moment"," de tirer ou de retirer les conducteurs ou câbles (",[60,838,839],{},"sous-section 5.2.9.3. point e.",[714,841,842,843,845],{},"Dans les boîtes, les conducteurs restent accessibles (",[60,844,785],{},"), ce qui suppose une boucle dans le boîtier.",[17,847,848,849,851,852,212],{},"La marge n’est donc pas un coussin de sécurité posé sur un calcul incertain, mais un poste de matériel avec une finalité. Qui l’applique forfaitairement documente le pourcentage, son origine et la version à laquelle il se rapporte. La détermination de la longueur de base est traitée dans ",[203,850,407],{"href":406}," ; le matériel d’accompagnement induit par chaque mode de pose dans ",[203,853,855],{"href":854},"\u002Ffr\u002Fblog\u002Fmodes-de-pose-rgie","Modes de pose selon le RGIE",[12,857,859],{"id":858},"combien-demplacements-libres-faut-il-prévoir-au-tableau","Combien d’emplacements libres faut-il prévoir au tableau ?",[17,861,862,863,866],{},"Le RGIE n’impose ",[221,864,865],{},"aucun"," emplacement libre. Un balayage intégral des neuf parties dans les versions néerlandaise, française et allemande ne fournit aucune référence citant un nombre de modules libres, un pourcentage ou une réserve minimale. Annoncer un chiffre, c’est annoncer une convention d’entreprise — ce qui est légitime, à condition de le dire.",[17,868,869],{},"Ce que le règlement exige à la place, et qui pousse pratiquement dans le même sens :",[711,871,872,882,888,893,898],{},[714,873,874,875,878,879,246],{},"Les circuits sont réalisés de manière à pouvoir être identifiés ultérieurement lors de la surveillance, du contrôle, de l’entretien, de la réparation, de la ",[221,876,877],{},"modification ou de l’extension"," de l’installation (",[60,880,881],{},"sous-section 3.1.3.1.",[714,883,884,885,887],{},"Les dispositifs de commande, de protection et de sectionnement sont repérés individuellement de façon claire, apparente et indélébile (",[60,886,881],{},"). Le matériel de repérage est donc un poste, pas une politesse.",[714,889,890,891,246],{},"Les circuits raccordés en amont de l’interrupteur général du tableau doivent être identifiés comme tels (",[60,892,881],{},[714,894,895,896,246],{},"Toute modification ou extension est reportée sur le plan de position, qui donne à tout moment la situation existante (",[60,897,241],{},[714,899,900,901,246],{},"Le matériel du tableau reste facilement accessible, en domestique sans moyens spéciaux (",[60,902,903],{},"sous-section 5.3.5.1. point c.",[17,905,906,907,910,911,914],{},"Et une règle de coffret plus souvent oubliée que les emplacements libres : dans les installations domestiques, les tableaux de répartition et de manœuvre sont de classe I ou II, ",[221,908,909],{},"avec paroi arrière et porte",", en matière incombustible et non hygroscopique ; l’inamovibilité de la paroi arrière est assurée pendant toute la durée de vie du matériel (",[60,912,913],{},"sous-section 5.3.5.1. point a.","). Porte et paroi arrière ne sont donc pas une variante d’équipement.",[12,916,918],{"id":917},"où-passe-la-frontière-entre-coût-matériel-et-coût-main-dœuvre","Où passe la frontière entre coût matériel et coût main-d’œuvre ?",[17,920,921],{},"À la question de savoir si la quantité découle du plan ou de l’exécution.",[17,923,924],{},"Le coût matériel découle de nombres de pièces et de mètres, et se dérive du modèle. Le coût main-d’œuvre découle des tracés, des supports, de l’accessibilité et de l’ordre d’intervention — des grandeurs qui ne figurent ni au schéma unifilaire ni au plan de position. La même prise coûte le même matériel qu’elle soit posée en cloison creuse ou dans du béton ; l’effort, lui, varie d’un facteur important.",[17,926,927],{},"En pratique, pour le chiffrage :",[711,929,930,937,940],{},[714,931,932,933,936],{},"Une liste de matériel n’est ",[221,934,935],{},"pas la moitié d’une offre",". C’est la moitié que l’on peut vérifier.",[714,938,939],{},"Les postes qui touchent aux deux — saignées, percements, carottages, échafaudage — relèvent explicitement du volet main-d’œuvre, faute de quoi ils n’apparaissent nulle part.",[714,941,942],{},"Le mode de pose tranche les deux volets à la fois : il détermine le matériel d’accompagnement nécessaire et la lourdeur de l’exécution.",[17,944,945,946,207,948,951],{},"Les chiffres des deux volets figurent dans ",[203,947,206],{"href":205},[203,949,950],{"href":210},"Comparatif de coût : soi-même ou électricien",". Cet article ne les répète volontairement pas : les prix vieillissent, la méthode non.",[12,953,955],{"id":954},"quelles-erreurs-de-chiffrage-rendent-la-liste-inutilisable","Quelles erreurs de chiffrage rendent la liste inutilisable ?",[711,957,958,969,975,981,987,998,1004,1010],{},[714,959,960,963,964,63,966,968],{},[221,961,962],{},"Compter par local au lieu de compter par circuit."," Les règles des huit — prises par circuit, circuits terminaux par différentiel (",[60,965,496],{},[60,967,85],{},") — génèrent des postes qui n’apparaissent dans aucune liste par pièce.",[714,970,971,974],{},[221,972,973],{},"Retenir la distance à vol d’oiseau plutôt que le cheminement."," À l’intérieur, la ligne droite se situe systématiquement bien en dessous du parcours réel : ce n’est pas une estimation, c’est une borne inférieure.",[714,976,977,980],{},[221,978,979],{},"Utiliser les longueurs nettes sans marge."," La marge existe pour les quatre raisons citées plus haut, pas par précaution.",[714,982,983,986],{},[221,984,985],{},"Oublier le matériel de terre",", parce qu’il tient en un symbole au schéma et relève du gros œuvre dans le calendrier.",[714,988,989,992,993,995,996,246],{},[221,990,991],{},"Traiter boîtes d’encastrement et boîtes de dérivation comme des accessoires",", alors qu’elles sont un contenu obligatoire du schéma (",[60,994,104],{},") et imposées en maçonnerie (",[60,997,127],{},[714,999,1000,1003],{},[221,1001,1002],{},"Ne pas distinguer plaques de finition et mécanismes."," Une combinaison triple, c’est une plaque et trois mécanismes, pas trois appareils complets.",[714,1005,1006,1009],{},[221,1007,1008],{},"Un circuit sans câble dessiné disparaît silencieusement"," et rend la longueur totale trop faible, sans qu’aucune ligne ne manque.",[714,1011,1012,1015],{},[221,1013,1014],{},"Reprendre des prix d’une version antérieure"," sans mentionner la date ni la source. Une quantité sans prix est incomplète ; un prix sans date est faux.",[12,1017,1019],{"id":1018},"comment-la-liste-de-matériel-est-elle-produite-dans-planelec-et-que-ne-dit-elle-pas","Comment la liste de matériel est-elle produite dans PlanElec — et que ne dit-elle pas ?",[17,1021,1022,1023,1026,1027,1030,1031,1034],{},"Via l’onglet ",[221,1024,1025],{},"Export",". La ",[221,1028,1029],{},"liste de matériel"," y figure comme document distinct ; le bouton ",[221,1032,1033],{},"Ouvrir l’aperçu du matériel"," l’affiche en détail, et le PDF provient de la même dérivation.",[17,1036,1037],{},"Ce que contient l’aperçu :",[711,1039,1040,1063,1073],{},[714,1041,1042,1043,63,1046,63,1049,63,1052,63,1055,63,1057,63,1060,212],{},"Des postes répartis en sept catégories : ",[221,1044,1045],{},"Consommateurs",[221,1047,1048],{},"Matériel et mécanismes",[221,1050,1051],{},"Enjoliveurs et plaques",[221,1053,1054],{},"Matériel d’installation",[221,1056,71],{},[221,1058,1059],{},"Câble",[221,1061,1062],{},"Répartition",[714,1064,1065,1066,207,1069,1072],{},"Deux vues : ",[221,1067,1068],{},"Par catégorie",[221,1070,1071],{},"Par local"," ; les postes sans affectation de local apparaissent à part, pour ne pas disparaître en silence.",[714,1074,1075],{},"Un bandeau indiquant le nombre de consommateurs, de postes, de pièces et la longueur de câble.",[17,1077,1078],{},"Depuis la mise à jour du 16 juillet 2026, l’aperçu décompose prises, interrupteurs et raccordements sélectionnés en éléments neutres du point de vue de la marque — mécanismes, enjoliveurs, plaques et boîtes d’installation. Les appareils raccordés à demeure comprennent la boîte de raccordement, la borne et le serre-câble ; les accessoires propres à l’appareil, non. Coffrets et peignes suivent le nombre de rangées et de modules modélisé.",[17,1080,1081,1082,1085,1086,1089],{},"Six ",[221,1083,1084],{},"hypothèses de base"," sont affichées explicitement dans l’aperçu au lieu d’agir en arrière-plan. La plus importante pour le chiffrage : les longueurs de câble sont des ",[221,1087,1088],{},"longueurs nettes issues du modèle ; la chute et les réserves de pose n’y sont pas intégrées."," La marge évoquée plus haut n’y figure donc pas encore. Aussi explicitement : la boîte d’encastrement suit un mur associé de façon univoque ; à défaut, le type cloison creuse est retenu dans les locaux comportant une cloison creuse, et le type encastré dans les autres cas.",[17,1091,1092,1093,1096],{},"Ce que la liste ne fait délibérément ",[221,1094,1095],{},"pas"," :",[711,1098,1099,1105,1111,1117],{},[714,1100,1101,1104],{},[221,1102,1103],{},"Elle ne donne aucun prix et ne vaut pas bon de commande."," Tous les postes sont neutres en marque et doivent être résolus en articles concrets et vérifiés professionnellement avant commande.",[714,1106,1107,1110],{},[221,1108,1109],{},"Elle n’invente aucune quantité manquante."," Un circuit sans tracé de câble apparaît à 0 m avec la mention « Routage manquant », au lieu d’être estimé. Une liste anormalement courte contient le plus souvent exactement ces lignes.",[714,1112,1113,1116],{},[221,1114,1115],{},"Elle n’ajoute aucun matériel de terre"," absent du modèle. Boucle de terre, conducteur de terre et liaisons équipotentielles sont un contenu du modèle, pas un ajout automatique.",[714,1118,1119,1120,1123],{},"Pour les installations PV, les ",[221,1121,1122],{},"données matériel DC incomplètes sont signalées comme remarques"," — strings, types de modules ou longueurs de tracé manquants — au lieu d’être comblées.",[12,1125,1127],{"id":1126},"ce-que-lautocontrôle-rgie-ne-fait-pas-ici","Ce que l’autocontrôle RGIE ne fait pas ici",[17,1129,1130,1131,1134],{},"L’autocontrôle évalue l’",[221,1132,1133],{},"installation"," projetée, pas l’exhaustivité d’une liste de matériel. Concrètement :",[711,1136,1137,1144,1151,1157,1160],{},[714,1138,1139,1140,1143],{},"Il ne vérifie ",[221,1141,1142],{},"aucune quantité",". Aucune règle ne signale qu’un poste manque, qu’il est sous-dimensionné ou compté deux fois.",[714,1145,1146,1147,1150],{},"Pour la terre, il vérifie seulement que liaison équipotentielle principale et prise de terre sont ",[221,1148,1149],{},"documentées"," et que le régime de neutre est cohérent — pas la section du conducteur posé ni le métré de boucle de terre nécessaire.",[714,1152,1139,1153,1156],{},[221,1154,1155],{},"ni prix, ni disponibilité, ni affectation d’article."," Des postes neutres en marque le restent.",[714,1158,1159],{},"Il ne calcule la chute de tension que si le chemin est complet ; si un tronçon manque, il signale une lacune de données plutôt qu’un résultat. Pour la liste de matériel, cela signifie que le métré de câble peut être incomplet sans qu’aucune règle ne se déclenche.",[714,1161,1162,1163,1166,1167,1169],{},"Il ne remplace ",[221,1164,1165],{},"ni"," la mesure ",[221,1168,1165],{}," le contrôle. L’évaluation officielle relève exclusivement d’un organisme agréé.",[12,1171,1173],{"id":1172},"pour-aller-plus-loin","Pour aller plus loin",[711,1175,1176,1180,1184,1188,1192,1196],{},[714,1177,1178],{},[203,1179,407],{"href":406},[714,1181,1182],{},[203,1183,855],{"href":854},[714,1185,1186],{},[203,1187,568],{"href":567},[714,1189,1190],{},[203,1191,563],{"href":562},[714,1193,1194],{},[203,1195,206],{"href":205},[714,1197,1198],{},[203,1199,950],{"href":210},[17,1201,1202],{},[203,1203,1205],{"href":1204},"\u002Ffr","Ouvrir PlanElec et dériver la liste de matériel →",[17,1207,1208],{},[60,1209,1210],{},"Base réglementaire : RGIE Livre 1 V06 — sous-sections 3.1.2.1., 3.1.2.2., 3.1.2.3., 3.1.3.1., 4.2.4.3., 5.2.1.2. avec tableau 5.1., 5.2.6.1., 5.2.6.2., 5.2.9.3., 5.2.9.5., 5.3.5.1., 5.3.5.2., 5.3.5.3., 5.4.2.1., 5.4.2.2., 5.4.3.5., 5.4.4.1. et 5.4.4.2. Font foi le texte officiel, l’état réel de l’installation et le contrôle de l’organisme agréé.",{"title":1212,"searchDepth":1213,"depth":1213,"links":1214},"",2,[1215,1216,1217,1218,1219,1220,1221,1222,1223,1224,1225,1226,1227],{"id":14,"depth":1213,"text":15},{"id":215,"depth":1213,"text":216},{"id":252,"depth":1213,"text":253},{"id":410,"depth":1213,"text":411},{"id":571,"depth":1213,"text":572},{"id":749,"depth":1213,"text":750},{"id":804,"depth":1213,"text":805},{"id":858,"depth":1213,"text":859},{"id":917,"depth":1213,"text":918},{"id":954,"depth":1213,"text":955},{"id":1018,"depth":1213,"text":1019},{"id":1126,"depth":1213,"text":1127},{"id":1172,"depth":1213,"text":1173},"guide","2026-08-31","Sept groupes de postes, leur dérivation depuis le schéma unifilaire et le plan de position, les postes systématiquement oubliés — matériel de terre, boîtes, réserve de câble, emplacements libres — et là où le RGIE fixe une quantité, et là où il n’en fixe aucune.","md","fr",{},true,"\u002Fblog\u002Fbill-of-materials-electrical.fr","13 min",12,{"title":6,"description":1230},"liste-de-materiel-installation-electrique","blog\u002Fbill-of-materials-electrical.fr",[1242,1243,1029,1244,1245,1246,1247,1248,1249],"RGIE","AREI","nomenclature","calcul de prix","mise à la terre","tableau électrique","schéma unifilaire","Belgique","tW7GQjyuIkr1Cfc0SWMluGUJAaMaCgruwLWZUd37ISw",{"id":1252,"title":1253,"articleId":1254,"body":1255,"category":1228,"date":1229,"description":1991,"extension":1231,"lastUpdated":1229,"locale":1232,"meta":1992,"navigation":1234,"path":1993,"publishDate":1229,"readTime":1994,"refreshInterval":1237,"seo":1995,"slug":1996,"stem":1997,"tags":1998,"__hash__":2004},"blog\u002Fblog\u002Fcable-routes-and-lengths.fr.md","Cheminements et longueurs de câbles : comment déterminer la longueur d’une canalisation sur un plan électrique ?","cable-routes-and-lengths",{"type":9,"value":1256,"toc":1978},[1257,1261,1264,1271,1373,1376,1380,1390,1407,1410,1417,1420,1424,1427,1540,1546,1558,1562,1565,1581,1585,1592,1595,1620,1624,1642,1645,1670,1673,1677,1680,1770,1777,1780,1784,1787,1793,1798,1810,1813,1817,1824,1831,1834,1837,1863,1875,1879,1882,1936,1938,1968,1973],[12,1258,1260],{"id":1259},"comment-déterminer-la-longueur-dune-canalisation-sur-un-plan-électrique","Comment déterminer la longueur d’une canalisation sur un plan électrique ?",[17,1262,1263],{},"Pas à vol d’oiseau, mais comme le parcours que le câble suit réellement : horizontalement le long des murs, verticalement aux deux extrémités jusqu’à l’appareil, avec les contournements de portes et de fenêtres et avec la réserve au tableau et dans la boîte. La ligne droite n’est pas une estimation approximative de ce parcours — c’est une borne inférieure, et à l’intérieur elle se situe régulièrement 30 à 60 % sous la valeur réelle.",[17,1265,1266,1267,1270],{},"Ce n’est pas un détail. La longueur est la donnée d’entrée de la chute de tension, donc un critère du choix de la section (",[60,1268,1269],{},"sous-section 5.2.1.2. point b.","), et c’est l’unité de mesure de votre calcul de matériel. Une longueur devinée rend les deux calculs inutilisables, sans que personne ne s’en aperçoive.",[21,1272,1273,1286],{},[24,1274,1275],{},[27,1276,1277,1280,1283],{},[30,1278,1279],{},"Portion du parcours",[30,1281,1282],{},"Ce qui la détermine",[30,1284,1285],{},"D’où vient la valeur",[43,1287,1288,1299,1310,1321,1333,1347,1361],{},[27,1289,1290,1293,1296],{},[48,1291,1292],{},"Parcours horizontal le long des murs",[48,1294,1295],{},"Plan et gabarit de pose autorisé",[48,1297,1298],{},"mesurable sur plan",[27,1300,1301,1304,1307],{},[48,1302,1303],{},"Segment vertical entre le gabarit et l’appareil",[48,1305,1306],{},"Hauteur de pose de l’appareil par rapport à la hauteur du parcours",[48,1308,1309],{},"hauteur de pose moins hauteur du parcours",[27,1311,1312,1315,1318],{},[48,1313,1314],{},"Segment vertical vers le niveau suivant",[48,1316,1317],{},"Hauteur sous plafond et position de la gaine technique",[48,1319,1320],{},"plan d’architecte, coupe",[27,1322,1323,1326,1331],{},[48,1324,1325],{},"Contournement des portes, fenêtres et baies",[48,1327,1328],{},[60,1329,1330],{},"sous-section 5.2.9.10. point b.",[48,1332,1298],{},[27,1334,1335,1338,1341],{},[48,1336,1337],{},"Tronçon enterré vers une annexe",[48,1339,1340],{},"Tracé de la tranchée plus une descente et une remontée à la profondeur",[48,1342,1343,1344],{},"minimum 0,60 m selon ",[60,1345,1346],{},"sous-section 5.2.9.2. point a.",[27,1348,1349,1352,1355],{},[48,1350,1351],{},"Réserve au point de raccordement dans le tableau",[48,1353,1354],{},"Position des bornes, repiquage, modifiabilité ultérieure",[48,1356,1357,1358],{},"convention d’entreprise — ",[221,1359,1360],{},"pas une norme",[27,1362,1363,1366,1369],{},[48,1364,1365],{},"Réserve dans la boîte, l’interrupteur ou l’appareil",[48,1367,1368],{},"Mode de raccordement et place dans le boîtier",[48,1370,1357,1371],{},[221,1372,1360],{},[17,1374,1375],{},"Les deux dernières lignes sont marquées ainsi à dessein : le RGIE ne fixe aucune valeur pour les marges et longueurs de réserve. Pourquoi une obligation en découle malgré tout, voir plus loin.",[12,1377,1379],{"id":1378},"pourquoi-la-ligne-droite-est-elle-systématiquement-trop-courte","Pourquoi la ligne droite est-elle systématiquement trop courte ?",[17,1381,1382,1383,1385,1386,1389],{},"Parce qu’une canalisation encastrée n’a pas le droit de cheminer en diagonale. La ",[60,1384,1330],{}," soumet les canalisations électriques noyées ",[221,1387,1388],{},"sans conduit"," dans les murs des locaux à un gabarit fixe :",[711,1391,1392,1395,1398,1401,1404],{},[714,1393,1394],{},"Le parcours ne comporte que des tracés horizontaux et verticaux ; les tracés horizontaux dans un plafond sont perpendiculaires aux parois verticales.",[714,1396,1397],{},"Les parcours horizontaux se trouvent entre 25 et 35 cm du plancher ou du plafond, et également entre 25 et 35 cm au-dessus de la face inférieure du linteau des fenêtres, à condition que les canalisations demeurent alors à 25 cm au moins sous le plafond.",[714,1399,1400],{},"Les parcours verticaux se trouvent le plus près possible d’un angle du local, ou entre 10 et 20 cm des chambranles ou huisseries des portes.",[714,1402,1403],{},"La pose hors de ce gabarit se fait à la verticale d’une machine ou d’un appareil électrique visibles.",[714,1405,1406],{},"L’épaisseur de l’enduit de revêtement n’est pas inférieure à 0,4 cm.",[17,1408,1409],{},"Le gabarit a une finalité de sécurité — celui qui percera plus tard doit savoir où rien ne passe — et un effet secondaire sur la longueur : chaque diagonale devient un escalier fait d’un segment horizontal et d’un segment vertical, et chaque baie de porte impose un contournement par le haut ou par le bas.",[17,1411,1412,1413,1416],{},"Un exemple chiffré. Un interrupteur se trouve à 6,0 m du tableau à vol d’oiseau, en travers de la pièce. Le long des murs, cela fait 4,2 m plus 3,6 m, soit 7,8 m. S’y ajoutent la montée depuis le point de raccordement du tableau vers le parcours horizontal, disons 0,9 m, et la descente du parcours vers la hauteur d’interrupteur de 110 cm, environ 0,8 m. Total : 9,5 m — ",[221,1414,1415],{},"58 % de plus que la ligne droite",", et sans la moindre réserve.",[17,1418,1419],{},"Pour un socle de prise de courant, cette dernière étape disparaît presque : si le parcours horizontal se situe entre 25 et 35 cm du plancher et la prise à 30 cm, la descente verticale est quasi nulle. C’est précisément pour cela qu’il vaut mieux traiter interrupteurs et prises séparément plutôt que d’appliquer un pourcentage forfaitaire à tout.",[12,1421,1423],{"id":1422},"que-change-le-mode-de-pose-pour-la-longueur","Que change le mode de pose pour la longueur ?",[17,1425,1426],{},"Il détermine si le gabarit s’applique et quelles contraintes géométriques s’ajoutent.",[21,1428,1429,1441],{},[24,1430,1431],{},[27,1432,1433,1436,1439],{},[30,1434,1435],{},"Mode de pose",[30,1437,1438],{},"Effet sur le tracé",[30,1440,426],{},[43,1442,1443,1456,1469,1482,1497,1510,1523],{},[27,1444,1445,1448,1451],{},[48,1446,1447],{},"Encastré sans conduit, dans les murs",[48,1449,1450],{},"Soumis au gabarit ; enduit ≥ 0,4 cm",[48,1452,1453],{},[60,1454,1455],{},"5.2.9.10. point b.",[27,1457,1458,1461,1464],{},[48,1459,1460],{},"Noyé dans le béton ou le ciment",[48,1462,1463],{},"Recouvrement ≥ 3 cm ; le tracé suit coffrage et armature, pas la ligne la plus courte",[48,1465,1466],{},[60,1467,1468],{},"5.2.9.10. point a.",[27,1470,1471,1474,1477],{},[48,1472,1473],{},"Encastré sous conduit",[48,1475,1476],{},"Le gabarit du 5.2.9.10 b ne s’applique pas selon la lettre du texte ; en revanche rayons de courbure minimaux et obligation de pouvoir à tout moment tirer ou retirer les conducteurs",[48,1478,1479],{},[60,1480,1481],{},"5.2.9.3. point e.",[27,1483,1484,1487,1490],{},[48,1485,1486],{},"Apparent, chemin de câbles, goulotte",[48,1488,1489],{},"Tracé plus libre, mais les efforts de traction dus au poids propre ne peuvent s’exercer sur les bornes dans les parties verticales",[48,1491,1492,63,1494],{},[60,1493,190],{},[60,1495,1496],{},"5.2.9.6.",[27,1498,1499,1502,1505],{},[48,1500,1501],{},"Sous moulures et plinthes",[48,1503,1504],{},"Le tracé suit la plinthe, donc en pratique le périmètre du local",[48,1506,1507],{},[60,1508,1509],{},"5.2.9.4.",[27,1511,1512,1515,1518],{},[48,1513,1514],{},"Enterré",[48,1516,1517],{},"Au moins 0,60 m de profondeur sauf impossibilité technique ⇒ deux segments verticaux en plus de la tranchée",[48,1519,1520],{},[60,1521,1522],{},"5.2.9.2. point a.",[27,1524,1525,1528,1535],{},[48,1526,1527],{},"Très basse tension (TBT)",[48,1529,1530,1531,1534],{},"Le ",[60,1532,1533],{},"point b."," du 5.2.9.10 est expressément exclu — sonnerie et circuits TBTS ne sont pas soumis au gabarit",[48,1536,1537],{},[60,1538,1539],{},"5.2.9.15. point b.",[17,1541,1542,1543,1545],{},"Les rayons de courbure des conduits cintrés sur chantier sont chiffrés : au moins dix fois le diamètre extérieur pour les conduits métalliques, huit fois pour les conduits thermoplastiques souples et cinq fois pour les conduits thermoplastiques rigides (",[60,1544,839],{},"). Pour un conduit de 25 mm, cela fait 12,5 à 25 cm de rayon par angle. Dans un logement comptant une dizaine de changements de direction par circuit, cela s’additionne.",[17,1547,1548,1549,1553,1554,212],{},"Quel mode de pose convient dans quel cas : voir ",[203,1550,1552],{"href":1551},"\u002Ffr\u002Fblog\u002Fpreflex-vs-pose-libre","Preflex ou pose libre"," ; les types de câbles eux-mêmes dans ",[203,1555,1557],{"href":1556},"\u002Ffr\u002Fblog\u002Fcable-xvb-vs-vob","XVB ou VOB",[12,1559,1561],{"id":1560},"compte-t-on-la-distance-simple-ou-laller-retour","Compte-t-on la distance simple ou l’aller-retour ?",[17,1563,1564],{},"La distance simple, du tableau au récepteur. Le conducteur de retour est dans la formule, pas dans la saisie : en monophasé le facteur 2, en triphasé le facteur √3. Saisir le double revient à compter le retour deux fois et à surdimensionner la section sans raison.",[17,1566,1567,1568,1571,1572,1576,1577,212],{},"Le critère lui-même ne figure pas comme chiffre dans le RGIE. La ",[60,1569,1570],{},"section 5.2.5."," — « Chute de tension » en français, « Spanningsval » en néerlandais, « Spannungsänderung » en allemand — demande seulement de limiter les chutes de tension aux valeurs décrites dans les règles de l’art. Les 3 % pour l’éclairage et 5 % pour les autres circuits terminaux, largement répandus, relèvent d’une interprétation selon l’IEC\u002FNBN HD 60364-5-52. Méthode de calcul, régimes de réseau et exemples : ",[203,1573,1575],{"href":1574},"\u002Ffr\u002Fblog\u002Fchute-de-tension-section-cable","Calculer la chute de tension"," ; la correspondance section–protection : ",[203,1578,1580],{"href":1579},"\u002Ffr\u002Fblog\u002Fsection-cable-disjoncteur","Section de câble par disjoncteur",[12,1582,1584],{"id":1583},"comment-compter-une-canalisation-scindée-à-une-boîte-de-dérivation","Comment compter une canalisation scindée à une boîte de dérivation ?",[17,1586,1587,1588,1591],{},"Physiquement il s’agit de plusieurs câbles, électriquement d’un seul parcours. Pour la chute de tension, c’est la somme sur ",[221,1589,1590],{},"l’ensemble"," du trajet, de la protection amont jusqu’au récepteur, et non le tronçon le plus long. Trois tronçons de 12 m donnent 36 m ; qui ne calcule que le dernier segment sous-estime le résultat de deux tiers.",[17,1593,1594],{},"Pourquoi le découpage doit néanmoins figurer dans le modèle :",[711,1596,1597,1603,1608,1614],{},[714,1598,1599,1600,1602],{},"Chaque tronçon peut avoir sa propre section et son propre mode de pose. Les deux relèvent du contenu obligatoire du schéma unifilaire pour les installations domestiques (",[60,1601,259],{},"), et les deux pèsent différemment dans le calcul.",[714,1604,1605,1606,246],{},"Les boîtes de connexion et de dérivation sont elles-mêmes un contenu obligatoire du schéma et doivent en outre figurer avec leur position sur le plan de position (",[60,1607,402],{},[714,1609,1610,1611,1613],{},"Les connexions ne peuvent se trouver qu’à des endroits définis : dans les tableaux, dans des boîtes de connexion ou de dérivation, aux bornes d’interrupteurs et de socles de prise, ou dans des boîtes de plafond suffisamment grandes (",[60,1612,767],{},"). Une jonction en pleine maçonnerie n’est pas une option de tracé, c’est une infraction.",[714,1615,1616,1617,1619],{},"Pour les installations sous conduit encastré s’ajoute ceci : dans les boîtes de connexion, de dérivation et de tirage, les conducteurs et câbles restent accessibles, et les tés et coudes sont interdits (",[60,1618,785],{},"). La boîte est donc aussi géométriquement un point de passage, pas un simple point de raccordement.",[12,1621,1623],{"id":1622},"quelles-marges-et-réserves-sont-dusage-et-que-dit-le-rgie","Quelles marges et réserves sont d’usage — et que dit le RGIE ?",[17,1625,1626,1627,1630,1631,1633,1634,1637,1638,1641],{},"Sur l’ampleur d’une marge, le RGIE ne dit ",[221,1628,1629],{},"rien",". Ni la ",[60,1632,1570],{},", ni la ",[60,1635,1636],{},"section 5.2.9.",", ni les prescriptions documentaires de la ",[60,1639,1640],{},"section 3.1.2."," ne mentionnent un pourcentage, une longueur de réserve ou un facteur de chute. Tout chiffre que vous utilisez à ce titre est une convention de votre entreprise — et doit apparaître comme telle dans votre note de calcul.",[17,1643,1644],{},"Ce que le règlement fixe en revanche, ce sont les conditions dont la réserve découle :",[711,1646,1647,1652,1657,1665],{},[714,1648,1649,1650,246],{},"Les raccordements aux appareils ne peuvent être soumis à des efforts de traction et de torsion (",[60,1651,823],{},[714,1653,1654,1655,246],{},"Dans les parties verticales, les efforts de traction dus au poids propre des canalisations ne peuvent s’exercer sur les bornes de raccordement (",[60,1656,829],{},[714,1658,1659,1660,836,1662,1664],{},"Dans les conduits, il doit être possible ",[221,1661,835],{},[60,1663,839],{},"). Un cheminement calculé au plus juste rend précisément cela impossible.",[714,1666,842,1667,1669],{},[60,1668,785],{},") — ce qui n’est pas réalisable sans une boucle dans le boîtier.",[17,1671,1672],{},"En pratique : la marge n’est pas un coussin de sécurité posé sur un calcul incertain, c’est un poste de matériel avec une finalité. Si vous l’appliquez forfaitairement en pourcentage de la longueur totale, documentez le pourcentage, son origine et l’état d’avancement auquel il se rapporte. Une valeur sans origine n’est plus traçable au stade suivant et se retrouve silencieusement dans les offres.",[12,1674,1676],{"id":1675},"la-longueur-doit-elle-figurer-sur-le-schéma-unifilaire","La longueur doit-elle figurer sur le schéma unifilaire ?",[17,1678,1679],{},"Ici le RGIE distingue deux cas, et cette distinction est souvent négligée.",[21,1681,1682,1697],{},[24,1683,1684],{},[27,1685,1686,1689,1692,1695],{},[30,1687,1688],{},"Document et type d’installation",[30,1690,1691],{},"Données exigées sur la canalisation",[30,1693,1694],{},"Longueur exigée ?",[30,1696,426],{},[43,1698,1699,1716,1737,1752],{},[27,1700,1701,1704,1707,1712],{},[48,1702,1703],{},"Schéma unifilaire, installation domestique",[48,1705,1706],{},"Type, section, nombre de conducteurs, mode de pose",[48,1708,1709],{},[221,1710,1711],{},"non",[48,1713,1714],{},[60,1715,104],{},[27,1717,1718,1721,1727,1732],{},[48,1719,1720],{},"Schéma de circuits, installation non domestique",[48,1722,1723,1724],{},"Mode de pose, nature, nombre et section des conducteurs ",[221,1725,1726],{},"et longueur des canalisations électriques",[48,1728,1729],{},[221,1730,1731],{},"oui",[48,1733,1734],{},[60,1735,1736],{},"3.1.2.2. point b.",[27,1738,1739,1742,1745,1747],{},[48,1740,1741],{},"Parties communes d’un immeuble d’habitation",[48,1743,1744],{},"Peut se limiter aux prescriptions applicables aux installations domestiques",[48,1746,1711],{},[48,1748,1749],{},[60,1750,1751],{},"3.1.2.1. point e.",[27,1753,1754,1757,1763,1766],{},[48,1755,1756],{},"Plan de position, installation domestique",[48,1758,1759,1760,1762],{},"La ",[221,1761,398],{}," des tableaux, boîtes de connexion et de dérivation, socles de prise, points lumineux, interrupteurs, machines et appareils fixes et sources",[48,1764,1765],{},"non — position, pas longueur",[48,1767,1768],{},[60,1769,143],{},[17,1771,1772,1773,1776],{},"Dans le logement, la longueur est donc une ",[221,1774,1775],{},"donnée de dimensionnement, pas une obligation de dessin",". C’est précisément ce qui la rend dangereuse : parce qu’elle ne doit apparaître nulle part sur le schéma, personne ne la vérifie — alors que la section qui en découle, elle, y figure et est vérifiée. Sans longueur consignée, impossible de justifier après coup pourquoi 2,5 mm² ici et 4 mm² là.",[17,1778,1779],{},"Pour une installation non domestique, c’est net : sans indication de longueur, le schéma de circuits est incomplet.",[12,1781,1783],{"id":1782},"de-la-longueur-à-la-liste-de-matériel-et-au-prix","De la longueur à la liste de matériel et au prix",[17,1785,1786],{},"Par deux sorties distinctes qui utilisent la même longueur résolue.",[17,1788,1759,1789,1792],{},[221,1790,1791],{},"liste de câbles"," donne une ligne par câble : type, nombre de conducteurs, section, longueur, De et Vers, les modes de pose rencontrés le long du tracé et la classe CPR ; s’y ajoutent le courant, la chute de tension en volts et en pourcent, la tension d’arrivée et la limite appliquée. Si une longueur manque, la ligne reste sans chiffre plutôt qu’avec une valeur estimée.",[17,1794,1759,1795,1797],{},[221,1796,1029],{}," regroupe les mêmes câbles par référence et les exprime en mètres ; s’il existe un prix au mètre, le poste en découle. Deux points méritent d’être dits explicitement :",[711,1799,1800,1807],{},[714,1801,1802,1803,1806],{},"Les longueurs indiquées sont des ",[221,1804,1805],{},"longueurs nettes du modèle ; les chutes et réserves de pose ne sont pas incluses."," La marge du paragraphe précédent n’y est donc pas.",[714,1808,1809],{},"Un circuit sans tracé de câble ne disparaît pas : il apparaît avec 0 m et la mention « Tracé manquant ». Une liste de matériel qui paraît étrangement maigre pour une maison entière contient généralement exactement ces lignes.",[17,1811,1812],{},"L’aperçu du projet fait la même distinction : il affiche soit une longueur totale complète, soit un sous-total marqué « ≥ » avec le nombre de longueurs manquantes, soit aucun chiffre. Une longueur totale réelle de 0 m et une longueur inconnue sont deux états différents.",[12,1814,1816],{"id":1815},"comment-planelec-pose-t-il-le-tracé-automatiquement-et-où-faut-il-encore-des-points-de-passage","Comment PlanElec pose-t-il le tracé automatiquement, et où faut-il encore des points de passage ?",[17,1818,1819,1820,1823],{},"Dans le plan de situation, sous ",[221,1821,1822],{},"Liaisons et câbles → Tracé de câble",". Si des câbles existent dans la topologie, vous câblez d’un coup tout le niveau actif ou une canalisation sélectionnée individuellement.",[17,1825,1826,1827,1830],{},"L’algorithme cherche le chemin le plus court ",[221,1828,1829],{},"le long des murs dessinés",", pas en travers de la pièce : les points de départ et d’arrivée sont projetés sur l’arête de mur la plus proche, puis une recherche de plus court chemin parcourt les nœuds de murs. S’il n’existe pas de chemin par les murs — par exemple parce que le plan y est interrompu — le tracé revient à la ligne directe. La longueur affichée suit exactement la polyligne visible ; les segments de mur volontairement obliques ne sont pas artificiellement rallongés à une mesure orthogonale.",[17,1832,1833],{},"Pour retoucher, sélectionnez une ligne de câble : un clic sur un tronçon insère un point de passage et démarre le déplacement, un double-clic le supprime. Un point déplacé n’est enregistré qu’au relâchement et s’annule en une seule étape. Lors de la reconstruction d’un circuit, la référence du câble, la longueur manuelle et le tracé enregistré sont conservés.",[17,1835,1836],{},"Quatre limites à connaître :",[711,1838,1839,1845,1851,1857],{},[714,1840,1841,1844],{},[221,1842,1843],{},"Le tracé automatique est bidimensionnel."," Il se situe dans le plan du niveau ; les différences de hauteur à l’intérieur d’un même étage — la montée vers le gabarit, la descente vers l’interrupteur — n’entrent pas dans la longueur. C’est à cela que servent les points de passage, ou la longueur manuelle.",[714,1846,1847,1850],{},[221,1848,1849],{},"Entre niveaux",", vous désignez explicitement un escalier, une gaine ou un passage vertical existant. PlanElec n’invente aucune liaison verticale. S’il en manque une ou si les hauteurs ne sont pas fiables, le tracé reste incomplet plutôt que de livrer une longueur apparente. Si la liaison existe, la différence de hauteur est comptée.",[714,1852,1853,1856],{},[221,1854,1855],{},"La longueur manuelle prime"," sur le tracé calculé. C’est l’échappatoire assumée pour les distances relevées — et l’endroit exact où une ancienne valeur peut subsister sans qu’on le remarque si le tracé change ensuite.",[714,1858,1859,1862],{},[221,1860,1861],{},"Le cheminement par les murs est une hypothèse d’exécution",", pas un constat. Que le câble soit dans le gabarit, sous conduit ou en apparent dépend du mode de pose que vous fixez par tronçon — pas du calculateur de tracé.",[17,1864,1865,1866,1870,1871,212],{},"Le mode d’emploi pas à pas se trouve dans le guide ",[203,1867,1869],{"href":1868},"\u002Ffr\u002Fhelp\u002Fcommandes-circuits-et-chemins-de-cables","Commandes, circuits et chemins de câbles",". Quel type d’interrupteur se trouve au bout de la chaîne : voir ",[203,1872,1874],{"href":1873},"\u002Ffr\u002Fblog\u002Fva-et-vient-permutateur-schema-unifilaire","Va-et-vient, permutateur ou double allumage",[12,1876,1878],{"id":1877},"ce-que-lautocontrôle-rgie-ne-fait-pas-concernant-la-longueur","Ce que l’autocontrôle RGIE ne fait pas concernant la longueur",[17,1880,1881],{},"L’autocontrôle est indicatif et n’évalue que les règles prises en charge, sur la base des données saisies. Concrètement sur la longueur :",[711,1883,1884,1891,1898,1908,1916,1929],{},[714,1885,1886,1887,1890],{},"Il ne calcule la chute de tension ",[221,1888,1889],{},"que si le parcours est complet",". S’il manque la longueur ne fût-ce que d’un tronçon entre la protection et le récepteur, ou si le parcours ne peut être remonté sans rupture, il signale une lacune de données au lieu d’un résultat. C’est voulu : une valeur calculée sur des données partielles serait systématiquement trop favorable.",[714,1892,1893,1894,1897],{},"Il travaille avec des ",[221,1895,1896],{},"hypothèses, pas des mesures"," : 80 % du courant assigné de la protection amont comme cas de charge, cos φ 0,95, cuivre, un modèle purement résistif sans réactance ni correction de température.",[714,1899,1900,1901,1904,1905,1907],{},"Les limites de 3 % et 5 % relèvent d’une ",[221,1902,1903],{},"interprétation IEC\u002FNBN",", pas du texte du RGIE. La ",[60,1906,1570],{}," renvoie aux règles de l’art.",[714,1909,1139,1910,1912,1913,1915],{},[221,1911,1095],{}," si le tracé dessiné correspond à la pose réelle, si le gabarit du ",[60,1914,1455],{}," est respecté, ni si une réserve est prévue. Aucun dessin ne le révèle.",[714,1917,1139,1918,1920,1921,1924,1925,1928],{},[221,1919,1095],{}," le courant admissible sous le mode de pose réel, le groupement et la température ambiante. La ",[60,1922,1923],{},"sous-section 4.4.1.4."," cite expressément ces facteurs d’influence ; le ",[60,1926,1927],{},"tableau 4.11."," qui s’y trouve ne limite que la protection par section et ne constitue pas une justification complète.",[714,1930,1162,1931,1166,1933,1935],{},[221,1932,1165],{},[221,1934,1165],{}," le contrôle. L’appréciation officielle relève exclusivement d’un organisme agréé.",[12,1937,1173],{"id":1172},[711,1939,1940,1945,1949,1953,1958,1962],{},[714,1941,1942],{},[203,1943,1944],{"href":1574},"Calculer la chute de tension : quelle longueur de câble est admissible ?",[714,1946,1947],{},[203,1948,1580],{"href":1579},[714,1950,1951],{},[203,1952,1552],{"href":1551},[714,1954,1955],{},[203,1956,1957],{"href":1556},"XVB ou VOB : quel câble pour quel usage ?",[714,1959,1960],{},[203,1961,1874],{"href":1873},[714,1963,1964],{},[203,1965,1967],{"href":1966},"\u002Ffr\u002Fblog\u002Fdessiner-plan-situation-guide","Dessiner un plan de position",[17,1969,1970],{},[203,1971,1972],{"href":1204},"Ouvrir PlanElec et tracer les câbles →",[17,1974,1975],{},[60,1976,1977],{},"Base réglementaire : RGIE Livre 1 V06 — sous-sections 3.1.2.1., 3.1.2.2., 3.1.2.3., 4.4.1.4. avec le tableau 4.11., 5.2.1.2., 5.2.6.1., 5.2.6.2., 5.2.9.2., 5.2.9.3., 5.2.9.4., 5.2.9.5., 5.2.9.6., 5.2.9.10. et 5.2.9.15., ainsi que la section 5.2.5. Font foi le texte officiel, l’état réel de l’installation et le contrôle de l’organisme agréé.",{"title":1212,"searchDepth":1213,"depth":1213,"links":1979},[1980,1981,1982,1983,1984,1985,1986,1987,1988,1989,1990],{"id":1259,"depth":1213,"text":1260},{"id":1378,"depth":1213,"text":1379},{"id":1422,"depth":1213,"text":1423},{"id":1560,"depth":1213,"text":1561},{"id":1583,"depth":1213,"text":1584},{"id":1622,"depth":1213,"text":1623},{"id":1675,"depth":1213,"text":1676},{"id":1782,"depth":1213,"text":1783},{"id":1815,"depth":1213,"text":1816},{"id":1877,"depth":1213,"text":1878},{"id":1172,"depth":1213,"text":1173},"La distance à vol d’oiseau est systématiquement trop courte. Gabarit de pose du 5.2.9.10, mode de pose et tracé, découpage aux boîtes de dérivation, marges relevant des règles de l’art et cas où le RGIE exige la longueur au schéma.",{},"\u002Fblog\u002Fcable-routes-and-lengths.fr","12 min",{"title":1253,"description":1991},"cheminements-et-longueurs-de-cables","blog\u002Fcable-routes-and-lengths.fr",[1242,1243,1999,2000,2001,2002,1029,2003,1248,1249],"cheminement de câble","longueur de câble","chute de tension","mode de pose","plan de position","8U0Ucp_LCvYvBQ1wBppO8pj_kqkdX23F2Pbp5SyTUAQ",{"id":2006,"title":2007,"articleId":2008,"body":2009,"category":1228,"date":1229,"description":3310,"extension":1231,"lastUpdated":1229,"locale":1232,"meta":3311,"navigation":1234,"path":3312,"publishDate":1229,"readTime":1994,"refreshInterval":1237,"seo":3313,"slug":3314,"stem":3315,"tags":3316,"__hash__":3321},"blog\u002Fblog\u002Finstallation-methods-arei.fr.md","Modes de pose selon le RGIE : quelle mention doit figurer au schéma unifilaire ?","installation-methods-arei",{"type":9,"value":2010,"toc":3295},[2011,2015,2037,2043,2373,2380,2384,2397,2417,2421,2426,2489,2495,2512,2516,2519,2541,2555,2574,2578,2581,2653,2659,2666,2670,2680,2683,2687,2697,2707,2717,2737,2757,2774,2778,2787,2790,2797,2801,2804,2904,2929,2933,2936,3109,3116,3123,3127,3130,3177,3181,3256,3258,3285,3290],[12,2012,2014],{"id":2013},"quels-modes-de-pose-le-rgie-reconnaît-il-et-lequel-figure-au-schéma-unifilaire","Quels modes de pose le RGIE reconnaît-il — et lequel figure au schéma unifilaire ?",[17,2016,2017,2018,2020,2021,2024,2025,2028,2029,2031,2032,729,2035,246],{},"Le RGIE énumère de manière limitative les modes de pose admis pour les canalisations basse tension : dix-sept lettres, de ",[60,2019,203],{}," à ",[60,2022,2023],{},"q",", à la ",[60,2026,2027],{},"sous-section 5.2.2.1.",", des lignes aériennes à la pose enterrée, en montage apparent, encastrée, sous plinthes et gouttières, jusqu’aux canalisations chauffantes dans les plafonds et planchers. Pour la plupart de ces modes, la ",[60,2030,1636],{}," ajoute des règles propres et contraignantes. Et le mode retenu n’est pas une affaire interne à l’installateur : le schéma unifilaire d’une installation domestique doit reprendre, à côté du type, de la section et du nombre de conducteurs, ",[221,2033,2034],{},"le mode de pose des canalisations électriques",[60,2036,259],{},[17,2038,2039,2040,2042],{},"La raison figure ailleurs dans le règlement. Le courant admissible IZ d’une canalisation est notamment fonction « du mode de pose et de l’environnement des canalisations électriques » (",[60,2041,1923],{},"). Sans le mode de pose, impossible donc de juger si une section convient au circuit — d’où sa présence au schéma.",[21,2044,2045,2063],{},[24,2046,2047],{},[27,2048,2049,2055,2057,2060],{},[30,2050,2051,2052,306],{},"Lettre (",[60,2053,2054],{},"5.2.2.1.",[30,2056,1435],{},[30,2058,2059],{},"Application courante en logement",[30,2061,2062],{},"Règles particulières",[43,2064,2065,2084,2100,2115,2130,2146,2162,2178,2194,2210,2226,2242,2258,2277,2294,2311,2327,2343,2358],{},[27,2066,2067,2069,2072,2075],{},[48,2068,203],{},[48,2070,2071],{},"lignes aériennes",[48,2073,2074],{},"alimentation d’une annexe",[48,2076,2077,2080,2081,306],{},[60,2078,2079],{},"5.2.9.1."," (renvoie au livre 3, ",[60,2082,2083],{},"chapitre 7.1.",[27,2085,2086,2089,2092,2095],{},[48,2087,2088],{},"b.1",[48,2090,2091],{},"enterrées directement",[48,2093,2094],{},"prise de jardin, carport",[48,2096,2097,2099],{},[60,2098,1522],{}," : 0,60 m de profondeur au minimum, câbles uniquement",[27,2101,2102,2105,2108,2111],{},[48,2103,2104],{},"b.2",[48,2106,2107],{},"enterrées avec protection mécanique",[48,2109,2110],{},"câble sous bande de protection",[48,2112,2113],{},[60,2114,1522],{},[27,2116,2117,2120,2123,2126],{},[48,2118,2119],{},"b.3",[48,2121,2122],{},"enterrées dans des fourreaux",[48,2124,2125],{},"traversée sous une allée ou une terrasse",[48,2127,2128],{},[60,2129,1522],{},[27,2131,2132,2135,2138,2141],{},[48,2133,2134],{},"c",[48,2136,2137],{},"lignes de contacts roulants ou glissants",[48,2139,2140],{},"sans objet en logement",[48,2142,2143],{},[60,2144,2145],{},"5.2.1.4. point a.",[27,2147,2148,2151,2154,2157],{},[48,2149,2150],{},"d",[48,2152,2153],{},"en montage apparent",[48,2155,2156],{},"XVB visible en cave, garage, local technique",[48,2158,2159,2161],{},[60,2160,190],{}," : câbles uniquement ; distance à la paroi ≤ 0,3 × diamètre extérieur",[27,2163,2164,2167,2170,2173],{},[48,2165,2166],{},"e",[48,2168,2169],{},"sous conduits encastrés",[48,2171,2172],{},"standard en construction neuve : VOB en préflex",[48,2174,2175],{},[60,2176,2177],{},"5.2.9.3.",[27,2179,2180,2183,2186,2189],{},[48,2181,2182],{},"f",[48,2184,2185],{},"sous moulures, plinthes et chambranles",[48,2187,2188],{},"rénovation, goulotte apparente",[48,2190,2191,2193],{},[60,2192,1509],{}," : conducteurs isolés ou câbles unipolaires uniquement",[27,2195,2196,2199,2202,2205],{},[48,2197,2198],{},"g",[48,2200,2201],{},"à l’air libre avec attaches ou sur chemins de câbles, échelles, tablettes, corbeaux",[48,2203,2204],{},"local technique, chaufferie",[48,2206,2207,2209],{},[60,2208,190],{}," : distance à toute paroi ≥ 0,3 × diamètre extérieur",[27,2211,2212,2215,2218,2221],{},[48,2213,2214],{},"h",[48,2216,2217],{},"sous goulottes et gouttières",[48,2219,2220],{},"tracé de distribution en local technique",[48,2222,2223,2225],{},[60,2224,1496],{}," : dans les gouttières, câbles uniquement",[27,2227,2228,2231,2234,2237],{},[48,2229,2230],{},"i",[48,2232,2233],{},"dans des gaines",[48,2235,2236],{},"tracé au-dessus du sol",[48,2238,2239],{},[60,2240,2241],{},"5.2.9.7.",[27,2243,2244,2247,2250,2253],{},[48,2245,2246],{},"j",[48,2248,2249],{},"dans des caniveaux ouverts, fermés ou remplis de sable",[48,2251,2252],{},"caniveau de sol, application industrielle",[48,2254,2255],{},[60,2256,2257],{},"5.2.9.8.",[27,2259,2260,2263,2266,2269],{},[48,2261,2262],{},"k",[48,2264,2265],{},"dans les vides de construction, alvéoles et blocs manufacturés",[48,2267,2268],{},"blocs creux, faux plafond",[48,2270,2271,207,2274],{},[60,2272,2273],{},"5.2.9.9.",[60,2275,2276],{},"4.3.3.5. point b.",[27,2278,2279,2282,2285,2288],{},[48,2280,2281],{},"l",[48,2283,2284],{},"dans les huisseries",[48,2286,2287],{},"cloison sèche, ossature bois",[48,2289,2290,207,2292],{},[60,2291,2273],{},[60,2293,2276],{},[27,2295,2296,2299,2302,2305],{},[48,2297,2298],{},"m",[48,2300,2301],{},"en encastrements directs, sans conduits",[48,2303,2304],{},"XVB directement dans la saignée",[48,2306,2307,2310],{},[60,2308,2309],{},"5.2.9.10."," : gabarit, béton ≥ 3 cm, enduit ≥ 0,4 cm",[27,2312,2313,2316,2319,2322],{},[48,2314,2315],{},"n",[48,2317,2318],{},"dans les canalisations préfabriquées",[48,2320,2321],{},"rare en logement",[48,2323,2324],{},[60,2325,2326],{},"5.2.9.11.",[27,2328,2329,2332,2335,2338],{},[48,2330,2331],{},"o",[48,2333,2334],{},"sur des isolateurs",[48,2336,2337],{},"installations anciennes",[48,2339,2340],{},[60,2341,2342],{},"5.2.9.12.",[27,2344,2345,2347,2350,2353],{},[48,2346,17],{},[48,2348,2349],{},"par immersion dans l’eau",[48,2351,2352],{},"technique de piscine",[48,2354,2355],{},[60,2356,2357],{},"5.2.2.1. point p.",[27,2359,2360,2362,2365,2368],{},[48,2361,2023],{},[48,2363,2364],{},"dans les plafonds, planchers et murs pour canalisations et panneaux chauffants",[48,2366,2367],{},"chauffage par le sol, trames chauffantes",[48,2369,2370],{},[60,2371,2372],{},"5.2.9.13.",[17,2374,2375,2376,2379],{},"D’autres modes de pose ne sont pas interdits, mais ils relèvent de la clause résiduelle : ils répondent « aux règles de l’art en la matière » (",[60,2377,2378],{},"sous-section 5.2.2.4.","). Travailler hors de la liste, c’est donc quitter le domaine pour lequel le RGIE formule lui-même une règle.",[12,2381,2383],{"id":2382},"quelle-est-la-différence-entre-le-point-e-et-le-point-m","Quelle est la différence entre le point e et le point m ?",[17,2385,2386,2387,2389,2390,2392,2393,2396],{},"C’est la confusion la plus fréquente, car dans le langage courant les deux s’appellent « encastré ». La différence est le conduit. Le point ",[60,2388,2166],{}," s’intitule littéralement « sous conduits encastrés » — le texte néerlandais dit « in verzonken buizen ». Le point ",[60,2391,2298],{}," s’intitule au contraire « en encastrements directs, ",[221,2394,2395],{},"sans"," conduits ».",[17,2398,2399,2400,2402,2403,2406,2407,2402,2409,2412,2413,2416],{},"Ce n’est pas une nuance de vocabulaire mais la frontière entre deux corps de règles. Pour ",[60,2401,2166],{},", c’est la ",[60,2404,2405],{},"sous-section 5.2.9.3."," qui s’applique, avec les règles des conduits : rayons de courbure, conducteurs toujours enfilables et retirables, pas de connexion dans le conduit. Pour ",[60,2408,2298],{},[60,2410,2411],{},"sous-section 5.2.9.10."," avec le gabarit et les recouvrements minimaux. Le choix du matériel dans chaque cas et son coût sont comparés dans ",[203,2414,2415],{"href":1551},"préflex ou pose libre"," ; le présent article décrit la systématique dans laquelle ces deux variantes se situent.",[12,2418,2420],{"id":2419},"pourquoi-le-mode-de-pose-détermine-t-il-le-courant-admissible","Pourquoi le mode de pose détermine-t-il le courant admissible ?",[17,2422,1759,2423,2425],{},[60,2424,1923],{}," énumère cinq grandeurs dont dépend IZ. Le mode de pose en est une, et c’est la seule qui ne se lit pas sur le câble lui-même.",[21,2427,2428,2441],{},[24,2429,2430],{},[27,2431,2432,2438],{},[30,2433,2434,2435],{},"Grandeur selon ",[60,2436,2437],{},"4.4.1.4.",[30,2439,2440],{},"Ce qu’elle signifie sur le plan",[43,2442,2443,2453,2461,2469,2478],{},[27,2444,2445,2448],{},[48,2446,2447],{},"section des conducteurs",[48,2449,2450,2451,306],{},"mention au schéma unifilaire (",[60,2452,104],{},[27,2454,2455,2458],{},[48,2456,2457],{},"isolation des conducteurs",[48,2459,2460],{},"type de câble, par exemple XVB ou VOB",[27,2462,2463,2466],{},[48,2464,2465],{},"constitution de la canalisation électrique",[48,2467,2468],{},"unipolaire ou multipolaire, armure, écran",[27,2470,2471,2474],{},[48,2472,2473],{},"mode de pose et environnement",[48,2475,2450,2476,306],{},[60,2477,104],{},[27,2479,2480,2483],{},[48,2481,2482],{},"température ambiante",[48,2484,2485,2486],{},"emplacement de la canalisation, voir ",[60,2487,2488],{},"5.2.3.1.",[17,2490,2491,2492,2494],{},"Le calcul proprement dit ne figure pas dans le RGIE. Le texte se borne à dire que le courant admissible « est calculé conformément aux règles de l’art » (",[60,2493,2437],{},") et que les ministres compétents peuvent en fixer les modalités. En pratique, les tableaux et les facteurs de correction viennent donc de la série de normes NBN HD 60364-5-52, et non du RGIE.",[17,2496,2497,2498,2500,2501,2504,2505,2508,2509,212],{},"Ce que le RGIE fixe, en revanche, est souvent confondu avec cela : le ",[60,2499,1927],{}," donne, pour les installations domestiques, l’intensité nominale ",[221,2502,2503],{},"maximale"," par section, séparément pour le coupe-circuit à fusible et pour le disjoncteur : pour 1,5 mm² 10 A et 16 A, pour 2,5 mm² 16 A et 20 A, pour 4 mm² 20 A et 25 A, pour 6 mm² 32 A et 40 A, pour 10 mm² 50 A et 63 A. Ce tableau ignore le mode de pose. C’est un plafond, pas une autorisation : la condition IZ ≥ IB de la ",[60,2506,2507],{},"sous-section 5.2.1.2. point a."," doit être satisfaite en plus. La correspondance section-protection est développée dans ",[203,2510,2511],{"href":1579},"section de câble et disjoncteur",[12,2513,2515],{"id":2514},"que-font-le-groupement-la-température-ambiante-et-lisolant-thermique-au-courant-admissible","Que font le groupement, la température ambiante et l’isolant thermique au courant admissible ?",[17,2517,2518],{},"Les trois abaissent IZ, et dans les trois cas le RGIE fournit la condition, pas le facteur.",[17,2520,2521,2524,2525,2528,2529,2532,2533,2536,2537,2540],{},[221,2522,2523],{},"Groupement."," Le RGIE fixe la limite avec précision : un câble ou conducteur isolé est ",[221,2526,2527],{},"installé séparément"," lorsqu’il se trouve à une distance supérieure ou égale à 20 mm de tout autre câble ou conducteur isolé (",[60,2530,2531],{},"section 2.7.1.","). En deçà, il est posé « en faisceaux ou en nappe ». Cette distinction a une conséquence directe dans le RGIE — mais pour la propagation du feu, pas pour l’échauffement : posés séparément, les conducteurs et câbles ont au moins la caractéristique F1 ou la classe Eca (",[60,2534,2535],{},"sous-section 5.2.7.2.",") ; en faisceaux ou en nappe, au moins F2 ou la classe Cca (",[60,2538,2539],{},"sous-section 5.2.7.3.","), et ce « indépendamment de la distance sur laquelle » ils sont effectivement groupés. Le facteur thermique de groupement, lui, relève à nouveau des règles de l’art.",[17,2542,2543,2546,2547,2550,2551,2554],{},[221,2544,2545],{},"Température ambiante."," La ",[60,2548,2549],{},"sous-section 5.2.3.1."," exige que les canalisations conviennent à la température ambiante locale la plus basse comme la plus élevée et ne soient posées que dans la plage de température indiquée par le fabricant. S’y ajoute la ",[60,2552,2553],{},"section 5.2.8."," : les canalisations ne peuvent être soumises à des températures nuisibles au voisinage de conduites de chauffage, d’air chaud ou de fumée, et doivent en être suffisamment éloignées ou séparées par un écran thermique. Poser une canalisation le long du collecteur de chauffage, c’est modifier son environnement thermique — lequel relève de la même mention que le mode de pose.",[17,2556,2557,2560,2561,2563,2564,2566,2567,2570,2571,2573],{},[221,2558,2559],{},"Isolant thermique."," Ici, une constatation honnête s’impose : le RGIE ne contient ",[221,2562,865],{}," facteur de réduction propre aux canalisations posées dans ou sous un isolant thermique. L’« isolation thermique » y apparaît comme précaution pour les températures inférieures à −25 °C (",[60,2565,2488],{},") et au chapitre des panneaux chauffants, où le matériau isolant en contact avec l’installation de chauffage doit être incombustible (",[60,2568,2569],{},"5.2.9.13. point b.5.","). Une canalisation posée dans une toiture inclinée isolée relève donc du « mode de pose et environnement » de ",[60,2572,2437],{}," et s’apprécie selon les règles de l’art — pas selon un tableau RGIE qui n’existe pas.",[12,2575,2577],{"id":2576},"où-la-mention-doit-elle-figurer-schéma-unifilaire-plan-de-position-ou-liste-de-matériel","Où la mention doit-elle figurer : schéma unifilaire, plan de position ou liste de matériel ?",[17,2579,2580],{},"Ces trois documents ont dans le RGIE des contenus obligatoires nettement distincts.",[21,2582,2583,2595],{},[24,2584,2585],{},[27,2586,2587,2590,2593],{},[30,2588,2589],{},"Document",[30,2591,2592],{},"Mode de pose exigé ?",[30,2594,426],{},[43,2596,2597,2611,2626,2640],{},[27,2598,2599,2602,2607],{},[48,2600,2601],{},"schéma unifilaire (domestique)",[48,2603,2604,2606],{},[221,2605,1731],{},", explicitement",[48,2608,2609],{},[60,2610,104],{},[27,2612,2613,2616,2622],{},[48,2614,2615],{},"plan de position (domestique)",[48,2617,2618,2619,2621],{},"non — il indique la ",[221,2620,398],{}," des éléments",[48,2623,2624],{},[60,2625,143],{},[27,2627,2628,2631,2636],{},[48,2629,2630],{},"schéma de circuits (non domestique)",[48,2632,2633,2635],{},[221,2634,1731],{},", avec la longueur et le nombre de conducteurs",[48,2637,2638],{},[60,2639,1736],{},[27,2641,2642,2644,2647],{},[48,2643,1029],{},[48,2645,2646],{},"non prescrite",[48,2648,2649,2650],{},"admise comme annexe au titre de ",[60,2651,2652],{},"3.1.2.1. point c.",[17,2654,2655,2656,2658],{},"La liste de matériel n’est pas un document obligatoire au sens du RGIE. La ",[60,2657,227],{}," permet seulement de compléter schémas et plans par des documents « précisant les différentes caractéristiques du matériel électrique et\u002Fou des produits ». Une liste de câbles reprenant le mode de pose par canalisation est exactement cela : utile pour le métré et l’exécution, mais elle ne dispense pas de porter la mention au schéma unifilaire lui-même.",[17,2660,2661,2662,2665],{},"La répartition entre schéma et plan de position est détaillée dans ",[203,2663,2664],{"href":406},"cheminements et longueurs de câbles"," ; on y lit aussi pourquoi la longueur n’est obligatoire que dans le schéma de circuits non domestique.",[12,2667,2669],{"id":2668},"quand-le-mode-de-pose-change-t-il-à-lintérieur-dune-même-canalisation","Quand le mode de pose change-t-il à l’intérieur d’une même canalisation ?",[17,2671,2672,2673,2676,2677,246],{},"Une canalisation n’a que rarement un seul mode de pose. Du tableau à travers le mur, sur le plafond, puis en terre et enfin contre une façade : cela en fait quatre. Le RGIE dispose d’une notion pour ce cas. On entend par ",[221,2674,2675],{},"origine du circuit"," l’origine de la canalisation électrique, « soit l’endroit où change la section, la nature ou la constitution de la canalisation électrique ainsi que son mode de pose » (",[60,2678,2679],{},"section 2.6.1.",[17,2681,2682],{},"Concrètement : chaque changement de mode de pose ouvre un tronçon d’étude distinct. Pour le dimensionnement, c’est le plus défavorable qui compte — une canalisation qui traverse deux mètres de faisceau de conduits avant de courir librement dans le plafond ne se dimensionne pas sur la partie libre. Pour le schéma : tous les modes rencontrés doivent être documentés, pas seulement le plus long.",[12,2684,2686],{"id":2685},"quelles-règles-sappliquent-aux-canalisations-encastrées","Quelles règles s’appliquent aux canalisations encastrées ?",[17,2688,2689,2690,2693,2694,2696],{},"Pour l’encastrement direct sans conduit (",[60,2691,2692],{},"point m","), la ",[60,2695,2411],{}," est la disposition de référence, et elle est inhabituellement concrète.",[17,2698,2699,2700,2703,2704,246],{},"Les canalisations noyées dans le ",[221,2701,2702],{},"béton ou le ciment"," sont couvertes d’une couche d’au moins 3 cm ; les conducteurs pourvus de la seule isolation principale ne peuvent pas y être noyés (",[60,2705,2706],{},"point a.",[17,2708,2709,2710,2713,2714,2716],{},"Les canalisations encastrées sans conduit ",[221,2711,2712],{},"dans les murs des locaux"," doivent en outre rester dans le gabarit (",[60,2715,1533],{},") :",[711,2718,2719,2722,2725,2728,2731,2734],{},[714,2720,2721],{},"le parcours ne comporte que des tracés horizontaux et verticaux, les tracés horizontaux dans un plafond étant perpendiculaires aux parois verticales ;",[714,2723,2724],{},"les parcours horizontaux se trouvent entre 25 et 35 cm du plancher ou du plafond, et également entre 25 et 35 cm au-dessus de la face inférieure du linteau des fenêtres, pour autant qu’ils demeurent alors à 25 cm au moins sous le plafond ;",[714,2726,2727],{},"les parcours verticaux se trouvent le plus près possible d’un angle du local ou entre 10 et 20 cm des chambranles ou huisseries des portes ;",[714,2729,2730],{},"hors de ce gabarit, seule la pose à la verticale d’une machine ou d’un appareil visible est admise ;",[714,2732,2733],{},"les canalisations ne sont soumises à aucune contrainte mécanique, ni lors de la pose ni ultérieurement, et sont fixées sans détérioration aux parois ;",[714,2735,2736],{},"l’épaisseur de l’enduit de revêtement n’est pas inférieure à 0,4 cm.",[17,2738,2739,2740,2742,2743,2746,2747,2750,2751,2754,2755,246],{},"Pour les conduits, c’est la ",[60,2741,2405],{}," qui prend le relais : les conducteurs ou câbles doivent pouvoir être enfilés et retirés à tout moment (",[60,2744,2745],{},"point e.","), les connexions dans le conduit sont interdites (",[60,2748,2749],{},"point f.","), et dans les conduits encastrés les tés et coudes sont proscrits tandis que les conducteurs restent accessibles dans les boîtes de jonction, de dérivation et de tirage (",[60,2752,2753],{},"point i.2.","). Les conduits en matériau combustible ne sont admis que noyés à 3 cm au moins dans des matériaux incombustibles (",[60,2756,2749],{},[17,2758,2759,2760,2763,2764,2766,2767,2770,2771,2773],{},"Une exception importante : pour les ",[221,2761,2762],{},"installations à très basse tension",", le gabarit de ",[60,2765,1455],{}," ne s’applique explicitement pas (",[60,2768,2769],{},"sous-section 5.2.9.15. point b.","). Les lignes de bus, de sonnerie et de commande en TBT ne doivent donc pas suivre le gabarit — les autres règles de la ",[60,2772,1636],{}," restent d’application.",[12,2775,2777],{"id":2776},"que-prévoit-le-rgie-pour-les-canalisations-enterrées","Que prévoit le RGIE pour les canalisations enterrées ?",[17,2779,1759,2780,2782,2783,2786],{},[60,2781,1346],{}," est l’une des dispositions les plus nettes du chapitre. Dans le sol et dans les fourreaux souterrains inaccessibles, seuls des ",[221,2784,2785],{},"câbles"," peuvent être posés, à l’exception des conducteurs de protection indépendants. La profondeur minimale est de 0,60 m mesurée à partir de la surface du sol, « sauf impossibilité technique ». Si cette profondeur ne peut être atteinte, la protection est assurée par un fourreau continu ou à joints étanches en matériau durable et résistant.",[17,2788,2789],{},"Le câble doit en outre remplir l’une de trois conditions : écran électrique mis à la terre avec armure ou gaine extérieure renforcée ; ou gaine extérieure résistante complétée par une couverture continue qui protège des outils lors de travaux de fouille et déborde des deux côtés ; ou pose dans un fourreau ou un système équivalent. L’une de ces conditions remplie, aucune mesure supplémentaire n’est requise pour la protection contre les chocs électriques.",[17,2791,2792,2793,2796],{},"Pour la signalisation dans le sol, le ",[60,2794,2795],{},"point d."," contient ses propres règles : repères aux extrémités des tronçons rectilignes, au moins tous les deux cents mètres, d’une surface d’au moins 0,01 m² et portant un éclair en relief. Les branchements des utilisateurs du réseau basse tension en sont dispensés.",[12,2798,2800],{"id":2799},"quel-câble-pour-quel-mode-de-pose","Quel câble pour quel mode de pose ?",[17,2802,2803],{},"Le mode de pose restreint le choix du câble, indépendamment de la section.",[21,2805,2806,2817],{},[24,2807,2808],{},[27,2809,2810,2812,2815],{},[30,2811,1435],{},[30,2813,2814],{},"Admis",[30,2816,426],{},[43,2818,2819,2832,2843,2854,2866,2879,2892],{},[27,2820,2821,2824,2827],{},[48,2822,2823],{},"enterré",[48,2825,2826],{},"câbles uniquement",[48,2828,2829],{},[60,2830,2831],{},"5.2.9.2. a.",[27,2833,2834,2837,2839],{},[48,2835,2836],{},"à l’air libre et en montage apparent",[48,2838,2826],{},[48,2840,2841],{},[60,2842,190],{},[27,2844,2845,2848,2850],{},[48,2846,2847],{},"gouttière",[48,2849,2826],{},[48,2851,2852],{},[60,2853,1496],{},[27,2855,2856,2859,2862],{},[48,2857,2858],{},"goulotte",[48,2860,2861],{},"également conducteurs isolés ; hors des locaux du service électrique, à parois pleines et couvercle ouvrable à l’outil",[48,2863,2864],{},[60,2865,1496],{},[27,2867,2868,2871,2874],{},[48,2869,2870],{},"moulures, plinthes et chambranles",[48,2872,2873],{},"conducteurs isolés ou câbles unipolaires",[48,2875,2876],{},[60,2877,2878],{},"5.2.9.4. b.",[27,2880,2881,2884,2887],{},[48,2882,2883],{},"conduits",[48,2885,2886],{},"conducteurs isolés ou câbles",[48,2888,2889],{},[60,2890,2891],{},"5.2.9.3. b.",[27,2893,2894,2897,2900],{},[48,2895,2896],{},"vides de construction",[48,2898,2899],{},"pas de conducteurs pourvus de la seule isolation principale",[48,2901,2902],{},[60,2903,2273],{},[17,2905,2906,2907,2909,2910,2913,2914,2917,2918,2921,2922,2924,2925,212],{},"S’y ajoute la classe de réaction au feu. Dans les ",[221,2908,2896],{}," ainsi que dans les ",[221,2911,2912],{},"moulures, plinthes ou chambranles en matériaux combustibles",", la ",[60,2915,2916],{},"sous-section 4.3.3.5. point b."," exige explicitement la caractéristique ou la classe de ",[60,2919,2920],{},"5.2.7.3."," — donc F2 ou au moins Cca. Une cloison à ossature bois est un vide de construction. Le type de câble adapté à chaque usage est traité dans ",[203,2923,1557],{"href":1556}," ; pour les locaux humides s’ajoutent les règles de volumes de ",[203,2926,2928],{"href":2927},"\u002Ffr\u002Fblog\u002Fcables-salle-de-bain-rgie","câbles de salle de bain et volumes RGIE",[12,2930,2932],{"id":2931},"comment-planelec-enregistre-t-il-le-mode-de-pose-et-que-montre-lexport","Comment PlanElec enregistre-t-il le mode de pose, et que montre l’export ?",[17,2934,2935],{},"PlanElec connaît douze modes de pose pertinents pour le logement et conserve pour chacun la référence RGIE dont il relève :",[21,2937,2938,2951],{},[24,2939,2940],{},[27,2941,2942,2945,2948],{},[30,2943,2944],{},"Choix dans PlanElec",[30,2946,2947],{},"Code court",[30,2949,2950],{},"Référence RGIE enregistrée",[43,2952,2953,2966,2982,2995,3008,3020,3032,3045,3058,3070,3083,3096],{},[27,2954,2955,2958,2961],{},[48,2956,2957],{},"en saillie",[48,2959,2960],{},"AP",[48,2962,2963],{},[60,2964,2965],{},"5.2.2.1. d",[27,2967,2968,2971,2974],{},[48,2969,2970],{},"conduit apparent sur paroi",[48,2972,2973],{},"AR",[48,2975,2976,2978,2979],{},[60,2977,2965],{}," \u002F ",[60,2980,2981],{},"5.2.9.3. h",[27,2983,2984,2987,2990],{},[48,2985,2986],{},"encastré dans gaine flexible",[48,2988,2989],{},"UR",[48,2991,2992],{},[60,2993,2994],{},"5.2.2.1. e",[27,2996,2997,3000,3003],{},[48,2998,2999],{},"encastré direct",[48,3001,3002],{},"UD",[48,3004,3005],{},[60,3006,3007],{},"5.2.2.1. m",[27,3009,3010,3013,3016],{},[48,3011,3012],{},"sous conduit",[48,3014,3015],{},"IR",[48,3017,3018],{},[60,3019,2177],{},[27,3021,3022,3025,3028],{},[48,3023,3024],{},"faisceau de conduits",[48,3026,3027],{},"RB",[48,3029,3030],{},[60,3031,2177],{},[27,3033,3034,3037,3040],{},[48,3035,3036],{},"cloison creuse \u002F panneau mural",[48,3038,3039],{},"HW",[48,3041,3042],{},[60,3043,3044],{},"5.2.2.1. k + l",[27,3046,3047,3050,3053],{},[48,3048,3049],{},"plinthe \u002F goulotte",[48,3051,3052],{},"FL",[48,3054,3055],{},[60,3056,3057],{},"5.2.2.1. f",[27,3059,3060,3062,3065],{},[48,3061,2823],{},[48,3063,3064],{},"EV",[48,3066,3067],{},[60,3068,3069],{},"5.2.2.1. b.1 + b.2",[27,3071,3072,3075,3078],{},[48,3073,3074],{},"enterré dans un fourreau",[48,3076,3077],{},"ER",[48,3079,3080],{},[60,3081,3082],{},"5.2.2.1. b.3",[27,3084,3085,3088,3091],{},[48,3086,3087],{},"chemin de câbles",[48,3089,3090],{},"KW",[48,3092,3093],{},[60,3094,3095],{},"5.2.2.1. g + h",[27,3097,3098,3101,3104],{},[48,3099,3100],{},"libre en plafond ou creux",[48,3102,3103],{},"FV",[48,3105,3106],{},[60,3107,3108],{},"5.2.2.1. g",[17,3110,3111,3112,3115],{},"Le mode de pose est attaché au tronçon, pas au câble entier : un cheminement sur le plan peut changer de mode d’un tronçon à l’autre, et chaque tronçon reçoit sa propre couleur avec le code de deux lettres. Au schéma unifilaire, ",[221,3113,3114],{},"un seul"," mode déterminant est tracé par défaut — le plus restrictif de ceux rencontrés. Les modes pour lesquels l’outil ne dispose d’aucune table de référence fiable reçoivent délibérément la priorité, plutôt que d’être masqués derrière un classement thermique inventé.",[17,3117,3118,3119,3122],{},"Depuis la mise à jour du 28 août 2026, les canalisations sous conduit, les faisceaux de conduits, les canalisations enterrées sous fourreau et les conduits apparents se choisissent séparément ; chaque mode de pose porte, dans le menu câble, l’éditeur, l’aperçu et le PDF, le même signe complet avec sa propre ligne support. Cette ligne support est précisément ce qui permet de distinguer l’apparent de l’encastré : elle représente le conducteur, et le côté où se trouvent les signes de paroi ",[221,3120,3121],{},"est"," l’information. Depuis le 29 août 2026, le mode de pose se clique directement dans le schéma ; le menu câble apparaît à l’endroit choisi et reste accessible dans le panneau des propriétés. Dans la liste de câbles, il apparaît en colonne propre « Mode de pose ».",[12,3124,3126],{"id":3125},"ce-que-lautocontrôle-rgie-ne-fait-pas-sur-ce-point","Ce que l’autocontrôle RGIE ne fait pas sur ce point",[17,3128,3129],{},"L’autocontrôle est indicatif. Pour le mode de pose, cela signifie concrètement :",[711,3131,3132,3140,3148,3160,3165],{},[714,3133,1139,3134,3136,3137,3139],{},[221,3135,1095],{}," le courant admissible sous le mode de pose encodé. Ce qui est vérifié, c’est la correspondance entre la section du câble et l’intensité nominale de la protection — c’est-à-dire le ",[60,3138,1927],{},", qui ignore le mode de pose. Le groupement, la température ambiante et l’isolant n’entrent dans aucun contrôle.",[714,3141,1139,3142,3144,3145,3147],{},[221,3143,1095],{}," le respect du gabarit de ",[60,3146,1455],{},", l’épaisseur de l’enduit ou du béton, ni la profondeur d’une canalisation enterrée. Ce sont des cotes sur chantier, pas des données du modèle.",[714,3149,3150,3151,3154,3155,2978,3157,3159],{},"Il vérifie ",[221,3152,3153],{},"une"," règle dépendante du mode de pose : les câbles posés dans les vides de construction doivent être sous conduit ou atteindre au moins la classe Cca (",[60,3156,2276],{},[60,3158,2920],{},"). Si la classe de réaction au feu manque, PlanElec signale une donnée absente et non une erreur ; si elle est inférieure à Cca sans conduit documenté, c’est une erreur.",[714,3161,1139,3162,3164],{},[221,3163,1095],{}," si le mode de pose encodé correspond à ce qui a réellement été posé ensuite. C’est un constat visuel sur place.",[714,3166,1162,3167,3169,3170,3172,3173,212],{},[221,3168,1165],{}," mesure ",[221,3171,1165],{}," contrôle ; l’appréciation officielle relève exclusivement d’un organisme agréé. L’étendue complète est décrite dans ",[203,3174,3176],{"href":3175},"\u002Ffr\u002Fhelp\u002Fce-que-verifie-l-autocontrole","ce que vérifie l’autocontrôle",[12,3178,3180],{"id":3179},"quelles-erreurs-ressortent-au-contrôle","Quelles erreurs ressortent au contrôle ?",[711,3182,3183,3194,3202,3211,3221,3229,3239,3247],{},[714,3184,3185,3188,3189,207,3191,3193],{},[221,3186,3187],{},"Conducteurs isolés au lieu de câbles en apparent ou en gouttière."," Des conducteurs VOB visibles contre le mur ou posés dans une gouttière contreviennent à ",[60,3190,190],{},[60,3192,1496],{}," : seuls les câbles y sont admis.",[714,3195,3196,3199,3200],{},[221,3197,3198],{},"Saignée hors gabarit."," Tracés en diagonale et parcours au milieu de la paroi : le classique de ",[60,3201,1455],{},[714,3203,3204,3207,3208,246],{},[221,3205,3206],{},"Recouvrement insuffisant."," Moins de 0,4 cm d’enduit au-dessus de la canalisation ou moins de 3 cm de béton pour les canalisations noyées (",[60,3209,3210],{},"5.2.9.10. points a. et b.",[714,3212,3213,3216,3217,3220],{},[221,3214,3215],{},"Connexion dans le conduit."," Bornes et connecteurs à l’intérieur d’un conduit sont interdits (",[60,3218,3219],{},"5.2.9.3. point f.",") ; les raccordements dans les boîtes de tirage et de jonction se font sur un bornier approprié.",[714,3222,3223,3226,3227,246],{},[221,3224,3225],{},"Conduit devenu inutilisable."," Coudes trop serrés ou conduits surchargés violent l’exigence de pouvoir enfiler et retirer les conducteurs à tout moment (",[60,3228,1481],{},[714,3230,3231,3234,3235,2978,3237,246],{},[221,3232,3233],{},"Vide de construction en Eca au lieu de Cca et sans conduit."," Constat fréquent en ossature bois et en faux plafond (",[60,3236,2276],{},[60,3238,2920],{},[714,3240,3241,3244,3245,246],{},[221,3242,3243],{},"Câble enterré trop peu profond."," Moins de 0,60 m sans fourreau continu (",[60,3246,1522],{},[714,3248,3249,3252,3253,3255],{},[221,3250,3251],{},"Mode de pose absent du schéma."," Un schéma unifilaire reprenant type, section et nombre de conducteurs mais pas le mode de pose est incomplet (",[60,3254,104],{},") — quelle que soit la qualité d’exécution de l’installation.",[12,3257,1173],{"id":1172},[711,3259,3260,3265,3269,3274,3279],{},[714,3261,3262],{},[203,3263,3264],{"href":1579},"Section de câble et disjoncteur",[714,3266,3267],{},[203,3268,407],{"href":406},[714,3270,3271],{},[203,3272,3273],{"href":1556},"XVB ou VOB : quel câble pour quel usage",[714,3275,3276],{},[203,3277,3278],{"href":1551},"Préflex ou pose libre",[714,3280,3281],{},[203,3282,3284],{"href":3283},"\u002Ffr\u002Fblog\u002Fschema-unifilaire","Réaliser un schéma unifilaire pas à pas",[17,3286,3287],{},[203,3288,3289],{"href":1204},"Ouvrir PlanElec et encoder les modes de pose →",[17,3291,3292],{},[60,3293,3294],{},"Base réglementaire : RGIE\u002FAREI livre 1 V06 — sections 2.6.1., 2.7.1., 2.7.2., 5.2.2., 5.2.8., sous-sections 3.1.2.1., 3.1.2.2., 3.1.2.3., 4.3.3.5., 4.4.1.4. avec le tableau 4.11., 5.2.1.2., 5.2.3.1., 5.2.7.2., 5.2.7.3. et section 5.2.9. avec les sous-sections 5.2.9.1. à 5.2.9.15. Le texte officiel, l’état réel de l’installation et le jugement de l’organisme agréé restent déterminants.",{"title":1212,"searchDepth":1213,"depth":1213,"links":3296},[3297,3298,3299,3300,3301,3302,3303,3304,3305,3306,3307,3308,3309],{"id":2013,"depth":1213,"text":2014},{"id":2382,"depth":1213,"text":2383},{"id":2419,"depth":1213,"text":2420},{"id":2514,"depth":1213,"text":2515},{"id":2576,"depth":1213,"text":2577},{"id":2668,"depth":1213,"text":2669},{"id":2685,"depth":1213,"text":2686},{"id":2776,"depth":1213,"text":2777},{"id":2799,"depth":1213,"text":2800},{"id":2931,"depth":1213,"text":2932},{"id":3125,"depth":1213,"text":3126},{"id":3179,"depth":1213,"text":3180},{"id":1172,"depth":1213,"text":1173},"Les dix-sept modes de pose de la sous-section 5.2.2.1, leurs règles particulières à la section 5.2.9, leur influence sur le courant admissible et l’endroit où la mention est obligatoire — avec la référence RGIE en regard de chaque affirmation.",{},"\u002Fblog\u002Finstallation-methods-arei.fr",{"title":2007,"description":3310},"modes-de-pose-rgie","blog\u002Finstallation-methods-arei.fr",[1242,1243,3317,1248,3318,3319,3320,1249],"modes de pose","courant admissible","pose de câbles","gabarit de pose","XnO16CX903WzGSzKEl5cZqrc7hoXgXXKGSlWAjrxeic",{"id":3323,"title":3324,"articleId":3325,"body":3326,"category":1228,"date":1229,"description":4418,"extension":1231,"lastUpdated":1229,"locale":1232,"meta":4419,"navigation":1234,"path":4420,"publishDate":1229,"readTime":4421,"refreshInterval":1237,"seo":4422,"slug":4423,"stem":4424,"tags":4425,"__hash__":4430},"blog\u002Fblog\u002Fmulti-storey-electrical-planning.fr.md","Installation électrique sur plusieurs étages : chaque niveau a-t-il besoin de son propre tableau ?","multi-storey-electrical-planning",{"type":9,"value":3327,"toc":4401},[3328,3332,3343,3354,3364,3368,3371,3509,3523,3527,3530,3539,3556,3567,3667,3699,3709,3713,3724,3727,3756,3763,3768,3772,3790,3811,3821,3827,3831,3834,3837,3913,3923,3931,3935,3942,3948,3960,3978,3991,3995,3998,4010,4026,4031,4035,4038,4053,4061,4075,4083,4096,4100,4107,4115,4119,4130,4133,4166,4179,4183,4193,4199,4217,4221,4224,4231,4244,4247,4275,4286,4290,4293,4298,4316,4321,4362,4364,4391,4396],[12,3329,3331],{"id":3330},"chaque-niveau-a-t-il-besoin-de-son-propre-tableau","Chaque niveau a-t-il besoin de son propre tableau ?",[17,3333,3334,3335,3338,3339,3342],{},"Non. Le RGIE ne connaît aucune règle du type « un tableau par étage ». Il impose un tableau principal de répartition et de manœuvre muni d’un interrupteur-sectionneur général dont l’intensité assignée, dans les installations domestiques, n’est pas inférieure à 40 A (",[60,3336,3337],{},"sous-section 5.3.5.1. point b.","), et il impose que les tableaux de répartition et de manœuvre des installations domestiques soient facilement accessibles sans moyens spéciaux (",[60,3340,3341],{},"point c.","). Qu’un second tableau à l’étage fasse partie de l’ensemble, c’est vous qui en décidez — pas la norme.",[17,3344,3345,3346,3349,3350,3353],{},"Ce que la norme impose en revanche, ce sont des limites de nombre, et ce sont elles qui font grimper le nombre de circuits dans une maison de rangée de trois ou quatre niveaux : le nombre de socles de prise de courant simples ou multiples est limité à huit par circuit terminal, et les circuits alimentant les appareils d’éclairage sont au moins au nombre de deux circuits distincts pour les unités d’habitation qui comprennent plus de deux locaux et\u002Fou emplacements (",[60,3347,3348],{},"sous-section 5.3.5.2. point b.","). S’y ajoute la limite de huit circuits terminaux au maximum par dispositif de protection à courant différentiel-résiduel à haute ou très haute sensibilité (",[60,3351,3352],{},"sous-section 4.2.4.3. point b.","). Un tableau divisionnaire découle de ces limites et des longueurs de canalisation — pas d’une limite d’étage.",[17,3355,3356,3357,3360,3361,3363],{},"Le terme que le RGIE emploie aide à structurer le raisonnement : un ",[221,3358,3359],{},"circuit élémentaire"," est la portion d’une installation électrique comprise entre deux dispositifs successifs de protection contre les surintensités — circuit principal ou circuit divisionnaire — ou existant en aval du dernier de ces dispositifs, et c’est alors un circuit terminal (",[60,3362,2679],{},"). La ligne montante qui alimente un tableau divisionnaire n’est donc pas un circuit terminal mais un circuit principal. Toutes les règles qui visent les circuits terminaux — les huit socles, les huit circuits par différentiel — ne s’y appliquent pas.",[12,3365,3367],{"id":3366},"quand-un-tableau-divisionnaire-par-étage-se-justifie-t-il-et-quand-non","Quand un tableau divisionnaire par étage se justifie-t-il — et quand non ?",[17,3369,3370],{},"La décision se lit dans quatre grandeurs observables : le nombre de circuits terminaux, le tracé le plus long, l’accessibilité et l’extension prévue. Le tableau ci-dessous résume ce qui se présente en pratique dans une habitation belge ; la colonne « norme » nomme la disposition qui crée la limite.",[21,3372,3373,3390],{},[24,3374,3375],{},[27,3376,3377,3380,3384,3387],{},[30,3378,3379],{},"Situation",[30,3381,3383],{"align":3382},"center","Un seul tableau suffit",[30,3385,3386],{"align":3382},"Tableau divisionnaire justifié",[30,3388,3389],{},"Référence RGIE",[43,3391,3392,3406,3421,3435,3450,3465,3479,3494],{},[27,3393,3394,3397,3400,3403],{},[48,3395,3396],{},"Deux niveaux, maison de rangée compacte, moins d’environ 15 circuits terminaux",[48,3398,3399],{"align":3382},"✓",[48,3401,3402],{"align":3382},"—",[48,3404,3405],{},"aucune prescription ; le nombre découle de 5.3.5.2. b et 4.2.4.3. b",[27,3407,3408,3411,3413,3415],{},[48,3409,3410],{},"Plus de 16 circuits terminaux, donc plus de deux différentiels sensibles",[48,3412,3402],{"align":3382},[48,3414,3399],{"align":3382},[48,3416,3417,3418,306],{},"8 circuits terminaux au maximum par différentiel sensible (",[60,3419,3420],{},"4.2.4.3. b",[27,3422,3423,3426,3428,3430],{},[48,3424,3425],{},"Canalisation la plus longue nettement au-delà de 25 à 30 m depuis le tableau",[48,3427,3402],{"align":3382},[48,3429,3399],{"align":3382},[48,3431,3432,3433,306],{},"chute de tension à limiter selon les règles de l’art (",[60,3434,1570],{},[27,3436,3437,3440,3442,3444],{},[48,3438,3439],{},"Combles avec pompe à chaleur, préparation de borne de recharge ou bureau prévus",[48,3441,3402],{"align":3382},[48,3443,3399],{"align":3382},[48,3445,3446,3447,306],{},"puissance d’alimentation à déterminer avec les facteurs de simultanéité (",[60,3448,3449],{},"section 3.2.1.",[27,3451,3452,3455,3457,3459],{},[48,3453,3454],{},"Tableau à la cave, étage accessible seulement par une échelle",[48,3456,3402],{"align":3382},[48,3458,3399],{"align":3382},[48,3460,3461,3462,306],{},"facilement accessible sans moyens spéciaux (",[60,3463,3464],{},"5.3.5.1. c",[27,3466,3467,3470,3472,3474],{},[48,3468,3469],{},"Tarifs d’énergie distincts ou compteur GRD propre par niveau",[48,3471,3402],{"align":3382},[48,3473,3399],{"align":3382},[48,3475,3476,3477,306],{},"panneaux distincts écartés de 10 cm au moins, ou tableaux distincts (",[60,3478,3464],{},[27,3480,3481,3484,3486,3488],{},[48,3482,3483],{},"Appartement locatif par étage, chacun avec sa propre installation",[48,3485,3402],{"align":3382},[48,3487,3399],{"align":3382},[48,3489,3490,3491,306],{},"chaque unité d’habitation est une installation domestique à part (",[60,3492,3493],{},"3.1.2.1. a",[27,3495,3496,3499,3501,3503],{},[48,3497,3498],{},"Rénovation, un étage reste provisoirement inchangé",[48,3500,3399],{"align":3382},[48,3502,3402],{"align":3382},[48,3504,3505,3506,306],{},"le contrôle est limité à la partie ajoutée ou modifiée (",[60,3507,3508],{},"6.4.7.3.",[17,3510,3511,3512,3515,3516,3518,3519,3522],{},"Deux arguments plaident souvent ",[221,3513,3514],{},"contre"," un second tableau : chaque tableau supplémentaire est un endroit de plus qui doit rester accessible, manœuvrable et entretenable sans moyens spéciaux (",[60,3517,3464],{},"), et il doit porter un repérage individuel avec la tension d’alimentation indiquée clairement de manière apparente (",[60,3520,3521],{},"sous-section 3.1.3.3. point a.","). Dans un duplex de deux chambres, cela coûte plus cher que ce qu’il fait économiser en câble.",[12,3524,3526],{"id":3525},"comment-dimensionner-la-ligne-montante-vers-le-tableau-divisionnaire","Comment dimensionner la ligne montante vers le tableau divisionnaire ?",[17,3528,3529],{},"En trois étapes, dont seule la dernière est chiffrée dans le RGIE.",[17,3531,3532,3535,3536,3538],{},[221,3533,3534],{},"D’abord la puissance d’alimentation."," En déterminant la puissance d’alimentation d’une installation ou d’une partie de celle-ci, il peut être tenu compte des facteurs de simultanéité et d’utilisation des récepteurs (",[60,3537,3449],{},"). Le RGIE n’y avance aucune valeur — quel facteur est approprié relève des règles de l’art et de l’usage réel de l’étage.",[17,3540,3541,3544,3545,3548,3552,3553,3555],{},[221,3542,3543],{},"Ensuite le courant admissible."," Le courant admissible ",[60,3546,3547],{},"I",[3549,3550,3551],"sub",{},"Z"," d’une canalisation électrique est fonction de la section des conducteurs, de leur isolation, de la constitution de la canalisation, du mode de pose et de l’environnement, ainsi que de la température ambiante (",[60,3554,1923],{},"). Une ligne montante qui parcourt 6 m à la verticale dans une gaine fermée n’a pas le même courant admissible que la même canalisation posée librement sur un chemin de câbles — le mode de pose fait partie du calcul, ce n’est pas de la cosmétique.",[17,3557,3558,3561,3562,729,3564,3566],{},[221,3559,3560],{},"Enfin le calibre."," Pour les installations domestiques, le ",[60,3563,1927],{},[60,3565,1923],{},") limite l’intensité nominale maximale du dispositif de protection en fonction de la section des conducteurs :",[21,3568,3569,3582],{},[24,3570,3571],{},[27,3572,3573,3576,3579],{},[30,3574,3575],{},"Section du conducteur",[30,3577,3578],{},"Intensité nominale maximale du coupe-circuit à fusible",[30,3580,3581],{},"Intensité nominale maximale du disjoncteur",[43,3583,3584,3595,3605,3615,3626,3637,3647,3657],{},[27,3585,3586,3589,3592],{},[48,3587,3588],{},"1,5 mm²",[48,3590,3591],{},"10 A",[48,3593,3594],{},"16 A",[27,3596,3597,3600,3602],{},[48,3598,3599],{},"2,5 mm²",[48,3601,3594],{},[48,3603,3604],{},"20 A",[27,3606,3607,3610,3612],{},[48,3608,3609],{},"4 mm²",[48,3611,3604],{},[48,3613,3614],{},"25 A",[27,3616,3617,3620,3623],{},[48,3618,3619],{},"6 mm²",[48,3621,3622],{},"32 A",[48,3624,3625],{},"40 A",[27,3627,3628,3631,3634],{},[48,3629,3630],{},"10 mm²",[48,3632,3633],{},"50 A",[48,3635,3636],{},"63 A",[27,3638,3639,3642,3644],{},[48,3640,3641],{},"16 mm²",[48,3643,3636],{},[48,3645,3646],{},"80 A",[27,3648,3649,3652,3654],{},[48,3650,3651],{},"25 mm²",[48,3653,3646],{},[48,3655,3656],{},"100 A",[27,3658,3659,3662,3664],{},[48,3660,3661],{},"35 mm²",[48,3663,3656],{},[48,3665,3666],{},"125 A",[17,3668,3669,3670,3673,3674,3676,3678,3679,3681,3684,3685,3687,3689,3690,3692,3694,3695,3697,212],{},"Ce tableau est un plafond, pas un conseil. Il dit ce qu’une section supporte comme calibre — pas quelle section convient à votre ligne montante. La condition supplémentaire figure à la ",[60,3671,3672],{},"sous-section 4.4.3.2."," : le courant nominal ",[60,3675,3547],{},[3549,3677,2315],{}," du dispositif de protection contre les surcharges doit être égal ou supérieur au courant d’emploi ",[60,3680,3547],{},[3549,3682,3683],{},"B"," du circuit et inférieur au courant admissible ",[60,3686,3547],{},[3549,3688,3551],{}," de la canalisation qu’il protège ; son courant conventionnel de fonctionnement ",[60,3691,3547],{},[3549,3693,2182],{}," est inférieur ou égal à 1,45 fois ",[60,3696,3547],{},[3549,3698,3551],{},[17,3700,3701,3704,3705,3708],{},[221,3702,3703],{},"Pratique de métier, pas norme :"," dans une habitation belge, une ligne montante vers un tableau d’étage aboutit le plus souvent à 6 mm² avec un disjoncteur C32, ou à 10 mm² avec un C40, et l’interrupteur-sectionneur du tableau divisionnaire est exécuté en 40 A — le plus petit calibre courant qui couvre la plage et qui satisfait de toute façon au minimum de ",[60,3706,3707],{},"5.3.5.1. b",". Le RGIE n’impose aucune de ces valeurs ; il ne fait que plafonner.",[12,3710,3712],{"id":3711},"la-ligne-montante-doit-elle-être-protégée-dans-le-tableau-principal","La ligne montante doit-elle être protégée dans le tableau principal ?",[17,3714,3715,3716,3719,3720,3723],{},"En principe oui, et à son origine. Un dispositif de protection contre les courts-circuits est placé à l’origine de tout circuit constitué de canalisations électriques ayant des caractéristiques équivalentes (",[60,3717,3718],{},"sous-section 4.4.2.2. point a.","). Pour les surcharges, le principe est le même : le dispositif est placé en principe à l’endroit où un changement de section, de nature, de mode de pose ou de constitution entraîne une réduction du courant admissible dans les conducteurs (",[60,3721,3722],{},"sous-section 4.4.3.1.",") — donc précisément là où le jeu de barres du tableau principal se prolonge en un câble de 6 mm².",[17,3725,3726],{},"Le RGIE prévoit trois dérogations que l’on rencontre réellement dans les installations réparties sur plusieurs niveaux :",[711,3728,3729,3738,3747],{},[714,3730,3731,3734,3735,246],{},[221,3732,3733],{},"La protection amont suffit."," Il est permis de ne pas installer de dispositif de protection contre les courts-circuits à l’origine d’un circuit, à condition de vérifier que le dispositif placé en amont puisse encore assurer sa fonction (",[60,3736,3737],{},"4.4.2.2. a",[714,3739,3740,3743,3744,246],{},[221,3741,3742],{},"Trois mètres de latitude."," Le dispositif de protection peut être placé sur la canalisation jusqu’à 3 m au maximum de l’origine du circuit, à condition que cette portion ne comporte aucun dispositif susceptible de causer des échauffements particuliers — connexions, dérivations, réductions de section, appareillage — et qu’elle ne soit pas placée à proximité de matériaux combustibles (",[60,3745,3746],{},"4.4.2.2. b",[714,3748,3749,3752,3753,246],{},[221,3750,3751],{},"La somme des dérivations."," Il est admis de se dispenser de toute protection contre les surcharges pour une canalisation électrique alimentant plusieurs dérivations protégées individuellement contre les surcharges, sous réserve que la somme des courants nominaux ou de réglage des dispositifs de protection de ces dérivations soit inférieure au courant nominal ou de réglage du dispositif qui protègerait contre les surcharges la canalisation considérée (",[60,3754,3755],{},"sous-section 4.4.3.3.",[17,3757,3758,3759,3762],{},"C’est la troisième dérogation que l’on lit de travers pour les lignes montantes. Elle n’autorise pas à laisser l’alimentation sans protection — elle autorise à omettre la protection ",[221,3760,3761],{},"contre les surcharges"," lorsque la somme des calibres en aval ne peut de toute façon jamais surcharger la canalisation. La protection contre les courts-circuits, elle, reste due. Dans un tableau divisionnaire comptant huit C16 et deux C20, les calibres totalisent 168 A ; une ligne montante de 6 mm² ne tombe pas sous cette dispense.",[17,3764,3765,3766,246],{},"N’oubliez pas le repérage : les circuits raccordés en amont de l’interrupteur général du tableau de répartition et de manœuvre se doivent d’être repérés comme tels (",[60,3767,881],{},[12,3769,3771],{"id":3770},"le-rgie-exige-t-il-la-sélectivité-entre-tableau-principal-et-tableau-divisionnaire","Le RGIE exige-t-il la sélectivité entre tableau principal et tableau divisionnaire ?",[17,3773,3774,3775,3778,3779,207,3782,3785,3786,3789],{},"Pour une installation domestique ordinaire : ",[221,3776,3777],{},"non."," Le mot sélectivité n’apparaît dans le RGIE que dans le contexte des installations de sécurité et des installations critiques. On y lit que le fonctionnement correct d’un circuit avec des consommateurs de sécurité, respectivement d’un circuit de sécurité, ne peut pas être affecté par un défaut électrique dans un autre circuit, et que « cela exige la sélectivité entre les dispositifs de protection » (",[60,3780,3781],{},"sous-sections 5.5.7.1. point a.",[60,3783,3784],{},"5.5.7.2."," ; formulation identique pour les installations critiques au ",[60,3787,3788],{},"chapitre 5.6.","). Pour la ligne montante vers l’étage des chambres d’une maison unifamiliale, aucune prescription équivalente n’existe.",[17,3791,3792,3793,729,3796,3799,3800,3803,3804,3807,3808,246],{},"Ce que le RGIE règle en revanche, c’est la ",[221,3794,3795],{},"coordination des dispositifs de protection placés en série",[60,3797,3798],{},"sous-section 4.4.1.3.",") — et ce n’est pas la sélectivité. Lorsque plusieurs dispositifs de protection sont placés en série, ils peuvent être coordonnés de façon qu’en cas de court-circuit en aval, le dispositif amont agisse pour limiter l’énergie traversant les dispositifs situés en aval à une valeur inférieure à celle que ces dispositifs et les canalisations qu’ils protègent peuvent supporter. Lorsque les dispositifs de protection en série sont des disjoncteurs, cette protection d’accompagnement porte un nom précis dans le texte : la ",[221,3801,3802],{},"filiation",". Pour en déterminer les caractéristiques, il est nécessaire de demander les tableaux de filiation des dispositifs de protection, établis conformément aux normes produit sur les disjoncteurs (",[60,3805,3806],{},"4.4.1.3.","). Dans les installations non domestiques, le repérage individuel du tableau de répartition et de manœuvre doit même indiquer l’utilisation de la technique de filiation, si elle est d’application (",[60,3809,3810],{},"sous-section 3.1.3.3. point b.",[17,3812,3813,3814,3816,3817,3820],{},"La différence en une phrase : la ",[221,3815,3802],{}," fait qu’un disjoncteur aval survit à un court-circuit qu’il ne pourrait pas couper seul, et lui confère un pouvoir de coupure ultime renforcé. La ",[221,3818,3819],{},"sélectivité"," fait qu’un défaut à l’étage ne plonge pas toute la maison dans le noir. La première est une question de sécurité, réglée par le RGIE ; la seconde est une question de confort et de disponibilité, et reste, hors installations de sécurité, un choix de conception.",[17,3822,3823,3826],{},[221,3824,3825],{},"Pratique de métier :"," un étagement — en amont plus lent et plus gros, en aval plus rapide et plus petit, et pour les différentiels en jouant en plus sur la sensibilité et le temps de retard — est courant et raisonnable dans les installations sur plusieurs niveaux. Mais c’est une mise en œuvre selon l’IEC 60364-5-53 et les données du fabricant, pas une obligation RGIE. Celui qui la défend dans un rapport de contrôle comme une « exigence RGIE » s’appuie sur une disposition qui n’existe pas.",[12,3828,3830],{"id":3829},"un-même-circuit-peut-il-alimenter-plusieurs-étages","Un même circuit peut-il alimenter plusieurs étages ?",[17,3832,3833],{},"Oui. Le RGIE ne connaît aucune règle qui limiterait un circuit terminal à un seul niveau. Un circuit d’éclairage qui alimente ensemble le hall, la cage d’escalier et le palier est admis — et c’est le cas normal dans les maisons de rangée belges, la cage d’escalier appartenant géométriquement aux deux niveaux.",[17,3835,3836],{},"Toutes les limites de nombre et d’affectation restent toutefois pleinement applicables, et elles se comptent par-delà les étages :",[21,3838,3839,3851],{},[24,3840,3841],{},[27,3842,3843,3846,3849],{},[30,3844,3845],{},"Limite",[30,3847,3848],{},"Valeur",[30,3850,426],{},[43,3852,3853,3866,3878,3889,3901],{},[27,3854,3855,3858,3861],{},[48,3856,3857],{},"Socles de prise de courant simples ou multiples par circuit terminal",[48,3859,3860],{},"huit au maximum",[48,3862,3863],{},[60,3864,3865],{},"5.3.5.2. b",[27,3867,3868,3871,3874],{},[48,3869,3870],{},"Circuits d’éclairage distincts pour plus de deux locaux et\u002Fou emplacements",[48,3872,3873],{},"deux au minimum",[48,3875,3876],{},[60,3877,3865],{},[27,3879,3880,3883,3885],{},[48,3881,3882],{},"Circuits terminaux par différentiel à haute ou très haute sensibilité",[48,3884,3860],{},[48,3886,3887],{},[60,3888,3420],{},[27,3890,3891,3894,3897],{},[48,3892,3893],{},"Différentiel placé à l’origine de l’installation électrique",[48,3895,3896],{},"300 mA au maximum",[48,3898,3899],{},[60,3900,3420],{},[27,3902,3903,3906,3909],{},[48,3904,3905],{},"Appareils fixes commandés par un appareil de manœuvre commun dans un circuit mixte",[48,3907,3908],{},"assimilés à 1 socle",[48,3910,3911],{},[60,3912,3865],{},[17,3914,3915,3916,3918,3919,3922],{},"Les troisième et quatrième lignes jouent ensemble dès qu’un tableau divisionnaire entre en scène. Immédiatement en aval du dispositif de protection placé à l’origine de l’installation électrique, au moins un dispositif de protection à courant différentiel-résiduel à haute ou très haute sensibilité est placé, auquel sont raccordés au moins les socles de prise de courant non destinés aux appareils fixes, l’éclairage, les lieux contenant une baignoire et\u002Fou une douche, ainsi que les lave-linges, sèche-linges et lave-vaisselles — avec au maximum huit circuits terminaux par différentiel (",[60,3917,3420],{},"). Une salle de bains à l’étage alimentée depuis le tableau qui s’y trouve a donc besoin de cette affectation ",[221,3920,3921],{},"là aussi"," ; le différentiel de 300 mA à l’origine de l’installation ne la remplace pas.",[17,3924,3925,3926,3928,3929,212],{},"Deux limites pratiques découlent du principe et non d’un article : un circuit terminal réparti sur trois niveaux devient long, et les chutes de tension dans les canalisations électriques doivent être limitées aux valeurs décrites dans les règles de l’art (",[60,3927,1570],{}," — le RGIE n’y cite lui-même aucun pourcentage). Et un circuit qui se disperse sur trois niveaux complique la recherche de défaut, parce qu’on ne met plus cette partie d’installation hors tension en un seul endroit. Comment établir les longueurs correspondantes de façon défendable : ",[203,3930,407],{"href":406},[12,3932,3934],{"id":3933},"comment-traverser-le-plancher-avec-la-ligne-montante","Comment traverser le plancher avec la ligne montante ?",[17,3936,3937,3938,3941],{},"La traversée elle-même est réglée. Dans les traversées de planchers, on assure la protection de la canalisation électrique, au ras du sol fini, contre les dégradations mécaniques et contre l’écoulement des liquides pouvant être répandus sur le sol fini. Si la traversée s’effectue en conducteurs posés sous conduits, ceux-ci sont étanches et leur extrémité supérieure fait saillie au-dessus du plancher, d’une hauteur au moins égale à celle des plinthes s’il en existe, et de 10 cm au moins (",[60,3939,3940],{},"sous-section 5.2.1.5.","). La même disposition impose, pour les traversées entre locaux pouvant présenter des différences importantes d’état hygrométrique, des précautions spéciales contre l’introduction et la condensation d’eau ; les conduits non obturés sont alors inclinés vers le local le plus humide.",[17,3943,3944,3945,3947],{},"Pour le tracé vertical à l’intérieur d’un étage, ce sont les gabarits de pose qui s’appliquent : les canalisations noyées sans conduit dans les murs des locaux ne comportent que des tracés horizontaux et verticaux, les parcours verticaux se trouvant le plus près possible d’un angle du local ou entre 10 et 20 cm des chambranles ou huisseries des portes (",[60,3946,1330],{},"). Les parcours horizontaux se situent entre 25 et 35 cm du plancher ou du plafond.",[17,3949,1759,3950,3952,3953,63,3956,3959],{},[221,3951,2858],{}," est un mode de pose nommé comme tel par le RGIE (",[60,3954,3955],{},"sous-section 5.2.2.1. point h.1",[60,3957,3958],{},"figure 5.11.",") — et le bon choix dès que plusieurs canalisations empruntent le même tracé vertical. Deux points d’attention :",[711,3961,3962,3968],{},[714,3963,3964,3965,246],{},"Lorsqu’on utilise dans une gouttière ou une goulotte des canalisations électriques de circuits à des tensions différentes, les connexions pour jonctions, raccordements ou dérivations sont exécutées dans des compartiments séparant les canalisations à tensions différentes (",[60,3966,3967],{},"sous-section 5.2.9.6.",[714,3969,3970,3971,3974,3975,3977],{},"Les conducteurs isolés et les câbles installés en faisceaux ou en nappe ont au moins la caractéristique F2 ou au moins la classe C",[3549,3972,3973],{},"ca"," — et cette disposition s’applique indépendamment de la distance sur laquelle ils sont effectivement installés en faisceau (",[60,3976,2539],{},"). Une gaine montante avec six câbles est exactement un faisceau de ce type.",[17,3979,3980,3983,3984,207,3987,3990],{},[221,3981,3982],{},"Ce qui ne figure pas ici :"," l’obturation coupe-feu de la gaine entre les étages. Le RGIE n’impose la résistance au feu des canalisations et des tableaux que dans le contexte des installations de sécurité et des installations critiques (",[60,3985,3986],{},"chapitres 5.5.",[60,3988,3989],{},"5.6.","). Le compartimentage d’un immeuble de logement relève du droit de la construction — les normes de base en prévention incendie et les prescriptions régionales — et non du RGIE. N’inventez donc pas d’article RGIE pour cela ; en cas de doute, renvoyez au dossier de sécurité incendie du projet.",[12,3992,3994],{"id":3993},"comment-mener-la-liaison-équipotentielle-sur-plusieurs-niveaux","Comment mener la liaison équipotentielle sur plusieurs niveaux ?",[17,3996,3997],{},"Il y a deux liaisons équipotentielles, et une seule des deux parcourt tout le bâtiment.",[17,3999,1759,4000,4003,4004,4007,4008,246],{},[221,4001,4002],{},"liaison équipotentielle principale"," est à l’échelle du bâtiment. Le conducteur principal d’équipotentialité a une section au moins égale à la moitié de celle du plus gros des conducteurs de protection de l’installation, le conducteur de terre étant exclu, avec un minimum de 6 mm² en cuivre ; sa section peut être limitée à 25 mm² en cuivre, ou à la section électriquement équivalente s’il s’agit d’un autre métal (",[60,4005,4006],{},"sous-section 5.4.4.1. point a.","). Ce conducteur possède une isolation de couleur vert-jaune et suit les prescriptions applicables aux conducteurs de protection (",[60,4009,1533],{},[17,4011,1759,4012,4015,4016,729,4019,4022,4023,246],{},[221,4013,4014],{},"liaison équipotentielle supplémentaire"," est au contraire expressément locale. Dans un lieu contenant une baignoire et\u002Fou une douche, elle relie localement toutes les masses du matériel électrique et tous les éléments conducteurs étrangers simultanément accessibles ",[221,4017,4018],{},"situés dans ce lieu",[60,4020,4021],{},"sous-section 7.1.4.4.","). Une salle de bains à l’étage reçoit donc sa propre liaison équipotentielle supplémentaire ; elle n’est pas remontée depuis le rez-de-chaussée. Les sections : au moins la moitié de celle du conducteur de protection relié à une masse, et en aucun cas moins de 2,5 mm² pour les conducteurs protégés mécaniquement, 4 mm² pour ceux qui ne le sont pas (",[60,4024,4025],{},"sous-section 5.4.4.2. point a.",[17,4027,4028,4029,212],{},"Conséquence pratique pour la ligne montante : le conducteur de protection monte dans le même câble ; les éléments conducteurs étrangers — canalisations d’eau et de chauffage, structures métalliques — sont raccordés là où ils pénètrent dans le bâtiment, via la liaison équipotentielle principale, et pas une seconde fois par étage. Quel schéma de mise à la terre se cache derrière tout cela : ",[203,4030,746],{"href":745},[12,4032,4034],{"id":4033},"comment-les-étages-doivent-ils-apparaître-sur-le-plan-de-position-et-le-schéma-unifilaire","Comment les étages doivent-ils apparaître sur le plan de position et le schéma unifilaire ?",[17,4036,4037],{},"Le RGIE sépare proprement les deux documents, et cette séparation détermine où un étage devient visible.",[17,4039,1530,4040,4042,4043,4045,4046,4048,4049,4052],{},[221,4041,2003],{}," indique la ",[221,4044,398],{}," des tableaux de répartition et de manœuvre, des boîtes de connexion, des boîtes de dérivation, des socles de prise de courant, des points lumineux, des interrupteurs, des machines et appareils fixes et des sources dont mention est faite sur le schéma unifilaire (",[60,4047,402],{},"). Le pluriel de « tableaux de répartition et de manœuvre » est le point décisif : un tableau divisionnaire à l’étage doit être ",[221,4050,4051],{},"situé"," sur le plan de position. Un schéma seul ne suffit pas.",[17,4054,1530,4055,4057,4058,4060],{},[221,4056,1248],{}," reprend les caractéristiques des canalisations électriques — type, section, nombre de conducteurs —, le mode de pose, le type et les caractéristiques des dispositifs de protection à courant différentiel-résiduel et contre les surintensités, les interrupteurs, les boîtes de connexion et de dérivation, les socles de prise de courant, les points lumineux, les machines et appareils fixes ainsi que les sources (",[60,4059,259],{},"). Pour une ligne montante, cela signifie concrètement : type, section, nombre de conducteurs et mode de pose sont des données obligatoires, pas un supplément.",[17,4062,4063,4064,4066,4067,4071,4072,4074],{},"Quant au repérage : sur le schéma unifilaire, chaque circuit élémentaire est identifié par une lettre majuscule ; chaque point lumineux, chaque socle de prise de courant et chaque unité de commande par un numéro donnant l’ordre dans lequel on les rencontre dans le circuit élémentaire, en partant du dispositif de protection contre les surintensités situé en amont. Sur le plan de position, ces mêmes éléments portent la lettre de leur circuit et le numéro d’ordre attribué au schéma unifilaire (",[60,4065,241],{},", figures 3.1. et 3.2.). Ce repérage est indépendant de l’étage — un circuit ",[4068,4069,4070],"code",{},"C"," qui court sur deux niveaux s’appelle ",[4068,4073,4070],{}," aux deux niveaux.",[17,4076,4077,4078,4080,4081,246],{},"Chaque tableau de répartition et de manœuvre est en outre repéré de manière claire, bien visible et indélébile par un repérage individuel, la tension d’alimentation étant indiquée clairement de manière apparente (",[60,4079,3521],{},"), et les dispositifs de commande, de protection et de sectionnement des circuits portent des repérages individuels, à moins que toute possibilité de confusion soit écartée (",[60,4082,881],{},[17,4084,4085,4088,4089,4093,4094,212],{},[221,4086,4087],{},"Ce que le RGIE n’impose pas :"," qu’une feuille distincte existe par étage, ou qu’un schéma distinct soit dessiné par tableau. Les deux relèvent de la pratique de représentation — une pratique très établie, parce qu’un plan de position superposant deux niveaux devient illisible. Comment les deux documents se délimitent : ",[203,4090,4092],{"href":4091},"\u002Ffr\u002Fblog\u002Fschema-unifilaire-vs-plan-situation","Schéma unifilaire ou plan de position"," ; la construction d’un plan de position est traitée dans ",[203,4095,1967],{"href":1966},[12,4097,4099],{"id":4098},"chaque-étage-a-t-il-besoin-dun-détecteur-de-fumée","Chaque étage a-t-il besoin d’un détecteur de fumée ?",[17,4101,4102,4103,4106],{},"Ce n’est ",[221,4104,4105],{},"pas une question RGIE."," Le RGIE n’impose pas de détecteur de fumée pour les installations domestiques. L’obligation vient du droit régional du logement : la Flandre, la Wallonie et Bruxelles règlent chacune de leur côté combien de détecteurs doivent être placés et où, et les exigences diffèrent aussi bien par le nombre par niveau que par le champ d’application aux logements existants.",[17,4108,4109,4110,4114],{},"Pour la planification sur plusieurs étages, seule la conséquence compte : la preuve des détecteurs ne relève pas du rapport de contrôle RGIE mais de la conformité régionale, et là où les détecteurs fonctionnent en 230 V, leur circuit apparaît tout normalement sur le schéma unifilaire. Les règles régionales en détail figurent dans ",[203,4111,4113],{"href":4112},"\u002Ffr\u002Fblog\u002Fdetecteur-fumee-obligatoire-belgique","Détecteur de fumée obligatoire en Belgique"," — là et pas ici, pour qu’il n’en existe qu’une seule version tenue à jour.",[12,4116,4118],{"id":4117},"que-vaut-il-si-vous-aménagez-un-étage-après-coup","Que vaut-il si vous aménagez un étage après coup ?",[17,4120,4121,4122,4125,4126,4129],{},"Un grenier aménagé constitue presque toujours une ",[221,4123,4124],{},"extension importante",". Le RGIE la définit comme une modification ou une extension d’une installation électrique qui a un impact supplémentaire — pas encore couvert par un contrôle de conformité — sur la sécurité des personnes ou des biens, et il cite expressément comme exemple « l’ajout d’un circuit dans une installation domestique » (",[60,4127,4128],{},"section 2.11.2.",", définitions). Un nouveau tableau divisionnaire avec six circuits y répond plusieurs fois.",[17,4131,4132],{},"Trois conséquences en découlent :",[711,4134,4135,4145,4158],{},[714,4136,4137,4140,4141,4144],{},[221,4138,4139],{},"Contrôle avant mise en usage."," Toute modification importante ou extension importante fait l’objet d’un contrôle de conformité avant la mise en usage de ladite modification ou extension ; ce contrôle de conformité est limité à la partie ajoutée ou modifiée de l’installation (",[60,4142,4143],{},"sous-section 6.4.7.3.","). L’ancienne installation du rez-de-chaussée n’est donc pas contrôlée automatiquement. Toute modification ou extension ayant un impact sur la partie non modifiée doit néanmoins être mentionnée dans le rapport de contrôle.",[714,4146,4147,4150,4151,4154,4155,4157],{},[221,4148,4149],{},"300 mA pour toute l’installation."," Dans le cas d’une modification importante ou d’une extension importante dans une ancienne installation électrique domestique, l’",[221,4152,4153],{},"ensemble"," de l’installation électrique est protégé par au moins un dispositif de protection à courant différentiel-résiduel dont le courant différentiel de fonctionnement est au maximum 300 mA (",[60,4156,3352],{},"). C’est la prescription qui rend régulièrement un aménagement de combles plus cher que prévu.",[714,4159,4160,4163,4164,246],{},[221,4161,4162],{},"Le plan de position suit."," Toute modification ou extension apportée à une installation électrique domestique est représentée sur le plan de position, qui donne à tout moment la situation existante des éléments de l’installation. Toute ancienne partie dont la réalisation sur place a été entamée avant le 1\u002F10\u002F1981 et figurant sur les schémas unifilaires est repérée par la mention « partie ancienne » (",[60,4165,241],{},[17,4167,4168,4169,4171,4172,4174,4175,212],{},"Pour les modifications qui ne peuvent ",[221,4170,1095],{}," être qualifiées d’importantes, il n’est pas obligatoire d’établir un nouveau schéma unifilaire ; une description succincte de la modification, comportant les nom, qualité et adresse du ou des responsables de l’exécution du travail, datée et signée par ceux-ci, suffit (",[60,4173,3493],{},"). Le plan de position doit malgré tout rester actuel. La séquence complète pour une construction neuve figure dans la ",[203,4176,4178],{"href":4177},"\u002Ffr\u002Fblog\u002Fschema-unifilaire-construction-neuve-checklist","Checklist schéma unifilaire construction neuve",[12,4180,4182],{"id":4181},"maison-unifamiliale-ou-immeuble-à-appartements-cela-change-t-il-la-réponse","Maison unifamiliale ou immeuble à appartements — cela change-t-il la réponse ?",[17,4184,4185,4186,4189,4190,4192],{},"Oui, et sur un point qu’on néglige souvent. Tant que tous les étages appartiennent à ",[221,4187,4188],{},"une seule"," unité d’habitation, l’ensemble constitue une seule installation domestique : un schéma unifilaire, un plan de position, un contrôle, et les limites de nombre de ",[60,4191,3865],{}," valent pour cette unique unité.",[17,4194,4195,4196,4198],{},"Dès qu’une unité d’habitation propre apparaît par étage, plusieurs installations domestiques apparaissent — chacune avec son propre tableau principal de répartition et de manœuvre muni d’un interrupteur-sectionneur général d’au moins 40 A (",[60,4197,3707],{},"), son propre schéma, son propre plan de position et son propre contrôle. Les huit socles par circuit terminal se comptent alors par unité d’habitation, pas par bâtiment.",[17,4200,4201,4202,4205,4206,4209,4210,4213,4214,212],{},"Pour les ",[221,4203,4204],{},"parties communes"," — éclairage de la cage d’escalier, installation de sonnerie, éclairage extérieur, local des compteurs — il existe un assouplissement explicite : en dérogation aux prescriptions applicables aux installations non domestiques, il est autorisé de se limiter, pour les schémas, plans et documents des parties communes d’un ensemble résidentiel, aux prescriptions d’application pour une installation domestique (",[60,4207,4208],{},"sous-section 3.1.2.1. point e.","). Il en va de même pour le repérage des tableaux de répartition et de manœuvre correspondants (",[60,4211,4212],{},"sous-section 3.1.3.3. point c.","). En pratique : pour le tableau de la cage d’escalier, un schéma unifilaire au format domestique habituel suffit — vous ne devez documenter ni courants de court-circuit présumés, ni impédances, ni catégories d’emploi, comme l’exigerait sinon ",[60,4215,4216],{},"3.1.2.2. b",[12,4218,4220],{"id":4219},"comment-aligner-les-étages-dans-planelec","Comment aligner les étages dans PlanElec ?",[17,4222,4223],{},"Dans PlanElec, les étages ne sont pas des dessins séparés mais des niveaux d’un même modèle de bâtiment. Vous les créez, vous les ordonnez et vous copiez le contour extérieur ou la structure du bâtiment d’un niveau au suivant ; un point zéro commun maintient les plans superposables, et un calque de référence affiche l’étage voisin avec une opacité réglable.",[17,4225,4226,4227,4230],{},"L’alignement proprement dit passe par des ",[221,4228,4229],{},"paires de points"," : vous placez le même point remarquable d’abord dans le plan courant, ensuite dans le plan de référence affiché. À partir de deux paires de points, le décalage et la rotation se déduisent automatiquement. PlanElec indique ensuite l’écart moyen et l’écart maximal en centimètres, ainsi que l’écart résiduel par paire de points ; les touches fléchées déplacent de 1 cm, avec Maj de 10 cm. L’échelle reste fixe — l’alignement est rigide et ne déforme jamais un étage pour faire coïncider des points.",[17,4232,4233,4234,63,4237,207,4240,4243],{},"La liaison verticale est un élément à part entière, décliné en ",[221,4235,4236],{},"escalier",[221,4238,4239],{},"gaine",[221,4241,4242],{},"zone montante",". Un escalier se dessine sur un étage et apparaît sur l’étage voisin comme le même élément manipulable, représenté en miroir — trait plein jusqu’à la ligne de coupe, pointillé au-delà. Les modifications apportées au jumeau projeté sont réécrites sur l’étage source. Une paire de points peut être reprise directement d’un escalier ou d’une gaine.",[17,4245,4246],{},"Côté électricité, il en dépend plus qu’il n’y paraît :",[711,4248,4249,4256,4263,4269],{},[714,4250,4251,4252,4255],{},"Les ",[221,4253,4254],{},"chaînes de commande"," sont valables à l’échelle du projet. Pendant le dessin, vous prolongez une chaîne via le sélecteur d’étage ; l’affichage indique combien de membres se trouvent à cet étage et combien au total, sur combien d’étages.",[714,4257,4258,4259,4262],{},"L’",[221,4260,4261],{},"affectation aux circuits"," fonctionne d’un étage à l’autre : des récepteurs situés sur plusieurs étages s’affectent ensemble à un disjoncteur existant, et la sélection survit au changement d’étage.",[714,4264,4251,4265,4268],{},[221,4266,4267],{},"cheminements de câbles physiques"," traversent bel et bien les étages, mais en deux sortes d’étapes : les étapes d’étage se dessinent et se modifient localement sur leur propre niveau, tandis que l’étape verticale se choisit via un connecteur au lieu d’être dessinée. La longueur verticale est déduite des hauteurs d’étage et du décalage horizontal tant qu’elle n’est pas mesurée — et elle entre dans la longueur de câble, donc dans le calcul de chute de tension. Les hauteurs d’étage sont marquées comme hypothèse ou comme valeur confirmée ; par défaut 2,50 m de hauteur libre et 0,30 m d’épaisseur de plancher.",[714,4270,4251,4271,4274],{},[221,4272,4273],{},"tableaux divisionnaires"," apparaissent comme un tableau à part entière, avec une ligne d’alimentation depuis le tableau amont. PlanElec crée pour cela le disjoncteur d’alimentation dans le tableau qui alimente, y raccroche l’interrupteur-sectionneur du tableau divisionnaire et propose calibre et section sur la base de la charge attendue et d’un facteur de simultanéité de 0,7. L’affectation d’un tableau à un étage naît du fait que vous placez le symbole du tableau dans le plan de cet étage.",[17,4276,4277,4278,4281,4282,4285],{},"À l’",[221,4279,4280],{},"exportation",", chaque étage reçoit sa propre page du plan de position, avec son propre cartouche ; les étages sans murs dessinés sont ignorés. Le schéma unifilaire est construit sur la base d’",[221,4283,4284],{},"une feuille par tableau",", tableau principal en tête, et un même tableau peut occuper plusieurs pages A4. Entre les feuilles, PlanElec place des renvois dans les deux sens : sur la feuille du tableau principal, le départ vers le tableau divisionnaire porte le numéro de feuille de ce dernier, et sur la feuille du tableau divisionnaire, l’alimentation porte le numéro de feuille du tableau amont.",[12,4287,4289],{"id":4288},"ce-que-lauto-contrôle-rgie-ne-fait-pas-ici","Ce que l’auto-contrôle RGIE ne fait pas ici",[17,4291,4292],{},"L’auto-contrôle est indicatif et n’évalue que les règles prises en charge, sur la base des données saisies. Pour les installations sur plusieurs étages, cela signifie concrètement :",[17,4294,4295],{},[221,4296,4297],{},"Ce qu’il vérifie :",[711,4299,4300,4303,4306,4313],{},[714,4301,4302],{},"Qu’une ligne d’alimentation entre deux tableaux dispose d’un dispositif de protection propre dans le tableau amont, pointe vers un tableau cible existant et soit affectée de manière cohérente des deux côtés. Si l’un de ces éléments manque, c’est une erreur, pas une remarque.",[714,4304,4305],{},"La chute de tension avec la longueur de câble réelle, étapes verticales des cheminements inter-étages comprises. Si la longueur manque, il n’en résulte pas une erreur mais un signalement non bloquant indiquant que la donnée fait défaut.",[714,4307,4308,4309,4312],{},"Un étagement entre différentiels amont et aval — explicitement comme ",[221,4310,4311],{},"recommandation de pratique selon l’IEC 60364-5-53",", non comme règle RGIE, et donc sous forme d’avertissement que vous pouvez outrepasser.",[714,4314,4315],{},"La couverture en détecteurs de fumée par étage — également comme avertissement outrepassable et explicitement comme renvoi au droit régional, pas au RGIE. Si des chambres ou des couloirs sont renseignés comme type de local, PlanElec signale local par local ; ce n’est que si aucun type de local de ce genre n’est reconnaissable à un étage que la règle par étage sert de repli.",[17,4317,4318],{},[221,4319,4320],{},"Ce qu’il ne vérifie pas :",[711,4322,4323,4329,4338,4344,4350,4356],{},[714,4324,1759,4325,4328],{},[221,4326,4327],{},"section de la ligne montante",". La canalisation entre deux tableaux est tenue à jour comme circuit avec dispositif de protection, mais pas comme segment de câble propre avec une section. La section affichée à la création est un aperçu de calcul et non une valeur enregistrée — elle n’apparaît donc ni dans le contrôle des sections ni dans le calcul de chute de tension.",[714,4330,4258,4331,4334,4335,4337],{},[221,4332,4333],{},"étagement en ampères"," entre la protection d’alimentation et l’interrupteur-sectionneur du tableau divisionnaire. C’est un choix délibéré : la coordination des dispositifs de protection placés en série passe, selon ",[60,4336,3806],{},", par l’énergie laissée passer et le pouvoir de coupure, donc par les tableaux de filiation du fabricant, et non par le courant nominal.",[714,4339,1759,4340,4343],{},[221,4341,4342],{},"sélectivité en court-circuit entre disjoncteurs."," Aucune règle ne la traite — et selon le RGIE, aucune obligation n’existe non plus en dehors des installations de sécurité et des installations critiques.",[714,4345,1759,4346,4349],{},[221,4347,4348],{},"zone montante comme concept."," C’est un type de connecteur vertical dans le plan, au service du cheminement des câbles ; aucune règle de contrôle ne l’évalue.",[714,4351,4258,4352,4355],{},[221,4353,4354],{},"obturation coupe-feu, le compartimentage et la fermeture des gaines."," Cela sort du RGIE et sort de l’auto-contrôle.",[714,4357,1162,4358,1166,4360,1935],{},[221,4359,1165],{},[221,4361,1165],{},[12,4363,1173],{"id":1172},[711,4365,4366,4371,4375,4379,4383,4387],{},[714,4367,4368],{},[203,4369,4370],{"href":567},"Planifier un tableau électrique : conception et modules",[714,4372,4373],{},[203,4374,1967],{"href":1966},[714,4376,4377],{},[203,4378,407],{"href":406},[714,4380,4381],{},[203,4382,746],{"href":745},[714,4384,4385],{},[203,4386,4178],{"href":4177},[714,4388,4389],{},[203,4390,4113],{"href":4112},[17,4392,4393],{},[203,4394,4395],{"href":1204},"Ouvrir PlanElec et créer les étages →",[17,4397,4398],{},[60,4399,4400],{},"Base réglementaire : RGIE Livre 1 V06 — sections 2.6.1. et 2.11.2., sous-sections 3.1.2.1., 3.1.2.2., 3.1.2.3., 3.1.3.1., 3.1.3.3., section 3.2.1., sous-section 4.2.4.3., chapitre 4.4. (sous-sections 4.4.1.3., 4.4.1.4. avec le tableau 4.11., 4.4.2.2., 4.4.3.1., 4.4.3.2., 4.4.3.3.), sous-sections 5.2.1.5., 5.2.2.1., 5.2.7.3., 5.2.9.6., 5.2.9.10., section 5.2.5., sous-sections 5.3.5.1., 5.3.5.2., 5.4.4.1., 5.4.4.2., 5.5.7.1., 5.5.7.2., 6.4.7.3. et 7.1.4.4. Font foi le texte officiel, l’état réel de l’installation et le contrôle de l’organisme agréé.",{"title":1212,"searchDepth":1213,"depth":1213,"links":4402},[4403,4404,4405,4406,4407,4408,4409,4410,4411,4412,4413,4414,4415,4416,4417],{"id":3330,"depth":1213,"text":3331},{"id":3366,"depth":1213,"text":3367},{"id":3525,"depth":1213,"text":3526},{"id":3711,"depth":1213,"text":3712},{"id":3770,"depth":1213,"text":3771},{"id":3829,"depth":1213,"text":3830},{"id":3933,"depth":1213,"text":3934},{"id":3993,"depth":1213,"text":3994},{"id":4033,"depth":1213,"text":4034},{"id":4098,"depth":1213,"text":4099},{"id":4117,"depth":1213,"text":4118},{"id":4181,"depth":1213,"text":4182},{"id":4219,"depth":1213,"text":4220},{"id":4288,"depth":1213,"text":4289},{"id":1172,"depth":1213,"text":1173},"Quand un tableau divisionnaire par étage se justifie, comment dimensionner et protéger la ligne montante, ce que le RGIE dit réellement de la sélectivité, et comment les étages apparaissent sur le plan de position et le schéma unifilaire — avec l’article RGIE à côté de chaque affirmation.",{},"\u002Fblog\u002Fmulti-storey-electrical-planning.fr","15 min",{"title":3324,"description":4418},"installation-electrique-plusieurs-etages","blog\u002Fmulti-storey-electrical-planning.fr",[1242,4426,4427,4428,1248,2003,4429,1249],"étages","tableau divisionnaire","ligne montante","plusieurs niveaux","YDJtlqf9WcJOfnxXhyvwFvm8dwFeOhkIhvtFma5u3f8",{"id":4432,"title":4433,"articleId":4434,"body":4435,"category":1228,"date":1229,"description":4992,"extension":1231,"lastUpdated":1229,"locale":1232,"meta":4993,"navigation":1234,"path":4994,"publishDate":1229,"readTime":4995,"refreshInterval":1237,"seo":4996,"slug":4997,"stem":4998,"tags":4999,"__hash__":5001},"blog\u002Fblog\u002Fswitch-types-single-line-diagram.fr.md","Va-et-vient, permutateur ou double allumage : lequel figure sur le schéma unifilaire ?","switch-types-single-line-diagram",{"type":9,"value":4436,"toc":4978},[4437,4441,4444,4455,4578,4588,4592,4603,4606,4615,4619,4622,4625,4650,4653,4657,4663,4672,4695,4701,4705,4708,4711,4723,4726,4730,4737,4744,4747,4751,4754,4764,4778,4791,4795,4802,4840,4846,4850,4853,4860,4867,4871,4878,4888,4894,4897,4903,4906,4909,4942,4946,4968,4973],[12,4438,4440],{"id":4439},"quel-montage-pour-combien-de-points-de-commande","Quel montage pour combien de points de commande ?",[17,4442,4443],{},"Le nombre d'endroits depuis lesquels vous voulez commander le même point lumineux détermine le montage. Un seul endroit : un interrupteur simple. Deux endroits : deux interrupteurs va-et-vient. Trois endroits ou plus : toujours deux va-et-vient aux extrémités, avec entre eux un permutateur par point de commande supplémentaire. Le double allumage sort de cette série : il commande séparément deux circuits depuis un seul endroit.",[17,4445,4446,4447,4450,4451,4454],{},"Ces fonctions ne relèvent pas du jargon de chantier : le ",[60,4448,4449],{},"tableau 2.23."," du RGIE, repris au ",[60,4452,4453],{},"chapitre 2.13.",", leur attribue à chacune un symbole propre. Le même tableau vaut pour le schéma unifilaire et pour le plan de position d'une installation domestique.",[21,4456,4457,4476],{},[24,4458,4459],{},[27,4460,4461,4464,4467,4470,4473],{},[30,4462,4463],{},"Points de commande",[30,4465,4466],{},"Montage",[30,4468,4469],{},"Description au tableau 2.23, rubrique E",[30,4471,4472],{},"Appareils",[30,4474,4475],{},"Liaison entre les points",[43,4477,4478,4495,4511,4528,4545,4561],{},[27,4479,4480,4483,4486,4489,4492],{},[48,4481,4482],{},"1",[48,4484,4485],{},"allumage simple",[48,4487,4488],{},"« Interrupteur — symbole général »",[48,4490,4491],{},"1 interrupteur",[48,4493,4494],{},"aucune",[27,4496,4497,4500,4503,4506,4509],{},[48,4498,4499],{},"1, mais deux groupes d'éclairage distincts",[48,4501,4502],{},"double allumage",[48,4504,4505],{},"« Commutateur unipolaire (double allumage : pour établir ou interrompre séparément deux circuits d'un seul endroit) »",[48,4507,4508],{},"1 commutateur à deux canaux",[48,4510,4494],{},[27,4512,4513,4516,4519,4522,4525],{},[48,4514,4515],{},"2",[48,4517,4518],{},"va-et-vient",[48,4520,4521],{},"« Interrupteur unipolaire va-et-vient (à deux directions : pour établir ou interrompre un circuit de deux endroits différents) »",[48,4523,4524],{},"2 interrupteurs va-et-vient",[48,4526,4527],{},"2 conducteurs de navette",[27,4529,4530,4533,4536,4539,4542],{},[48,4531,4532],{},"3",[48,4534,4535],{},"va-et-vient avec permutateur",[48,4537,4538],{},"« Commutateur intermédiaire pour va-et-vient … associé avec deux interrupteurs va-et-vient aux deux extrémités »",[48,4540,4541],{},"2 va-et-vient + 1 permutateur",[48,4543,4544],{},"2 navettes par tronçon",[27,4546,4547,4550,4553,4556,4559],{},[48,4548,4549],{},"n ≥ 3",[48,4551,4552],{},"va-et-vient avec permutateurs",[48,4554,4555],{},"idem",[48,4557,4558],{},"2 va-et-vient + (n − 2) permutateurs",[48,4560,4544],{},[27,4562,4563,4566,4569,4572,4575],{},[48,4564,4565],{},"illimité",[48,4567,4568],{},"commande par boutons-poussoirs",[48,4570,4571],{},"« Bouton-poussoir » associé à « Télérupteur »",[48,4573,4574],{},"1 bouton-poussoir par endroit + 1 télérupteur au tableau",[48,4576,4577],{},"1 ligne de commande commune, boutons en parallèle",[17,4579,4580,4581,4584,4585,4587],{},"Le RGIE ne prescrit pas lui-même ces nombres de conducteurs : ils découlent du principe de montage. Ce qu'il impose, c'est que le schéma unifilaire mentionne le type, la section et le ",[221,4582,4583],{},"nombre de conducteurs"," de chaque canalisation, ainsi que les interrupteurs eux-mêmes (",[60,4586,259],{},"). Un va-et-vient dessiné comme un simple circuit d'éclairage omet donc une donnée obligatoire.",[12,4589,4591],{"id":4590},"quelle-différence-entre-un-va-et-vient-et-un-double-allumage","Quelle différence entre un va-et-vient et un double allumage ?",[17,4593,4594,4595,4598,4599,4602],{},"Les deux se présentent comme un mécanisme « double », mais font l'inverse l'un de l'autre. Le va-et-vient bascule un circuit vers deux sorties possibles : associé à un second va-et-vient, il commande ",[221,4596,4597],{},"le même"," point lumineux depuis deux endroits. Le commutateur unipolaire à double allumage commande ",[221,4600,4601],{},"deux circuits différents"," séparément, depuis un seul endroit.",[17,4604,4605],{},"Conséquence pratique : un double allumage ne remplace jamais un va-et-vient, ni l'inverse. Poser un double allumage dans un couloir où il faut deux points de commande donne deux touches qui allument chacune sa propre lampe, pas une lampe commandée des deux côtés.",[17,4607,4608,4609,4612,4613,246],{},"Attention aussi à la terminologie. Le texte français du RGIE écrit « commutateur intermédiaire pour va-et-vient » là où le chantier dit ",[60,4610,4611],{},"permutateur",", et « commutateur unipolaire (double allumage) » là où l'on dit interrupteur double. Si vous employez d'autres appellations, reprenez la description du tableau 2.23 dans la légende de vos plans — le RGIE autorise tout symbole clairement identifiable pour autant qu'il soit défini dans cette légende (",[60,4614,241],{},[12,4616,4618],{"id":4617},"combien-de-conducteurs-faut-il-pour-un-va-et-vient","Combien de conducteurs faut-il pour un va-et-vient ?",[17,4620,4621],{},"Entre les deux va-et-vient courent deux navettes. S'y ajoutent la phase vers le premier interrupteur, le conducteur commandé du second interrupteur vers le point lumineux, le neutre jusqu'au luminaire et le conducteur de protection là où il est requis. Un permutateur ne change pas ce principe : il s'intercale dans les navettes, avec deux conducteurs de chaque côté.",[17,4623,4624],{},"Deux règles RGIE encadrent le choix de ces conducteurs :",[711,4626,4627,4640],{},[714,4628,4629,4632,4633,729,4636,4639],{},[221,4630,4631],{},"Section."," Pour les canalisations qui ne font pas partie intégrante d'un appareil, une section inférieure à 2,5 mm² est en principe interdite. Le ",[60,4634,4635],{},"tableau 5.1.",[60,4637,4638],{},"sous-section 5.2.1.2.",") admet expressément 1,5 mm² pour les « canalisations électriques appartenant à des circuits ne comportant pas de socle de prise de courant » — c'est exactement le cas d'un circuit d'éclairage pur avec ses interrupteurs.",[714,4641,4642,4645,4646,4649],{},[221,4643,4644],{},"Couleur."," La combinaison vert-jaune est réservée aux conducteurs de protection et d'équipotentialité ; l'usage du vert et\u002Fou du jaune pour l'isolant d'un conducteur actif est interdit (",[60,4647,4648],{},"sous-section 5.1.6.2.","). Le bleu est réservé au neutre dans les circuits qui en comportent un. Lorsque le circuit ne comporte pas de neutre, le conducteur bleu d'un câble multiconducteur peut servir à un autre usage — sauf comme conducteur de protection ou d'équipotentialité. Une navette peut donc être bleue dans un câble sans neutre, jamais vert-jaune.",[17,4651,4652],{},"Pour les types de câbles, le tableau 2.23 donne ses propres exemples : un câble XVB Cca comportant un certain nombre de conducteurs d'une section donnée, ou des conducteurs H07V-U Eca posés dans un tube encastré. Portez au schéma le type réellement posé et le mode de pose réel : les deux font partie du contenu obligatoire du schéma unifilaire.",[12,4654,4656],{"id":4655},"quel-symbole-sur-le-schéma-unifilaire-quel-symbole-sur-le-plan-de-position","Quel symbole sur le schéma unifilaire, quel symbole sur le plan de position ?",[17,4658,4659,4660,212],{},"Le symbole est le même — le tableau 2.23 vaut pour les deux documents. La différence tient à la question à laquelle chacun répond, et surtout au ",[221,4661,4662],{},"repérage",[17,4664,4665,4666,4668,4669,4671],{},"Le schéma unifilaire doit faire apparaître les interrupteurs, au même titre que les boîtes de jonction et de dérivation, les socles de prise de courant, les points lumineux, les machines et appareils fixes, les protections et les caractéristiques des canalisations (",[60,4667,259],{},"). Chaque circuit élémentaire reçoit une lettre majuscule ; chaque point lumineux, chaque socle et chaque unité de commande reçoit un numéro d'ordre à partir du dispositif de protection contre les surintensités situé en amont (",[60,4670,241],{},", figure 3.1.).",[17,4673,4674,4675,4678,4679,4681,4682,729,4685,4687,4688,4691,4692,4694],{},"Le plan de position doit indiquer l'",[221,4676,4677],{},"emplacement"," de ces mêmes interrupteurs (",[60,4680,402],{},"). Et c'est là que se trouve la règle la plus souvent omise : chaque interrupteur et chaque unité de commande sont identifiés par la lettre du circuit dans lequel ils se trouvent ",[221,4683,4684],{},"et par le numéro d'ordre du point lumineux ou de l'appareil qu'il commande",[60,4686,241],{},", figure 3.2.). Deux va-et-vient qui commandent ensemble le point lumineux ",[4068,4689,4690],{},"B3"," portent donc tous deux la mention ",[4068,4693,4690],{},", et non deux numéros propres consécutifs.",[17,4696,4697,4698,212],{},"C'est précisément pourquoi la chaîne de commande n'est pas un détail cosmétique : sans relation établie entre l'interrupteur et son point lumineux, ce repérage ne peut pas être correct. L'articulation entre les deux documents est développée dans ",[203,4699,4700],{"href":4091},"schéma unifilaire et plan de position",[12,4702,4704],{"id":4703},"quand-préférer-des-boutons-poussoirs-avec-télérupteur-à-un-montage-à-permutateurs","Quand préférer des boutons-poussoirs avec télérupteur à un montage à permutateurs ?",[17,4706,4707],{},"À partir de trois ou quatre points de commande, le câblage d'un montage à permutateurs enfle vite : chaque point supplémentaire demande deux navettes aller et retour. Des boutons-poussoirs raccordés en parallèle sur une ligne de commande unique, actionnant un télérupteur, passent mieux à l'échelle. La rubrique E du tableau 2.23 contient les deux symboles nécessaires : le « bouton-poussoir » et le « télérupteur ».",[17,4709,4710],{},"Deux points d'attention :",[711,4712,4713,4716],{},[714,4714,4715],{},"Le télérupteur se trouve dans le tableau de répartition et de manœuvre : c'est donc là qu'il figure au schéma unifilaire, avec sa protection en amont. Ce n'est pas une propriété de l'interrupteur du couloir.",[714,4717,4718,4719,4722],{},"Le RGIE admet explicitement les « auxiliaires de commandes » et les « dispositifs électroniques » comme dispositif de commande, aux côtés des interrupteurs et des disjoncteurs (",[60,4720,4721],{},"sous-section 5.3.3.2. point b.","). Un télérupteur ou un relais n'est donc pas un montage dérogatoire — mais il doit répondre aux normes correspondantes.",[17,4724,4725],{},"Une variante voisine est la minuterie ou l'interrupteur horaire ; le tableau 2.23 leur consacre également un symbole. Le choix entre télérupteur et minuterie est fonctionnel, non normatif : le premier maintient l'état jusqu'à l'impulsion suivante, la seconde retombe après une durée réglée.",[12,4727,4729],{"id":4728},"un-interrupteur-peut-il-être-unipolaire-et-peut-il-couper-le-neutre","Un interrupteur peut-il être unipolaire — et peut-il couper le neutre ?",[17,4731,4732,4733,4736],{},"Unipolaire, oui. La ",[60,4734,4735],{},"sous-section 5.3.3.2. point c."," prévoit explicitement que, si des dangers ne peuvent en résulter, il est permis de ne pas couper tous les conducteurs actifs. Un interrupteur d'éclairage classique qui coupe la phase entre dans ce cadre.",[17,4738,4739,4740,4743],{},"La même disposition pose immédiatement une limite : ",[221,4741,4742],{},"sauf pour l'exécution des mesures, un dispositif de commande unipolaire n'est pas placé sur le conducteur neutre."," Un interrupteur unipolaire raccordé par erreur sur le neutre laisse l'appareil sous tension alors qu'il paraît éteint. C'est un constat classique lors d'un contrôle, et ce n'est pas déductible d'un dessin : cela se vérifie hors tension, sur place.",[17,4745,4746],{},"La coupure bipolaire reste possible et parfois souhaitable, par exemple pour un appareil raccordé à demeure qui doit pouvoir être séparé du réseau. Le tableau 2.23 propose à cet effet l'« interrupteur bipolaire » et l'« interrupteur bipolaire va-et-vient ». La polarité est donc une propriété distincte de la fonction de commande, pas un autre montage.",[12,4748,4750],{"id":4749},"combien-de-points-lumineux-une-chaîne-de-commande-peut-elle-alimenter","Combien de points lumineux une chaîne de commande peut-elle alimenter ?",[17,4752,4753],{},"Deux règles RGIE se mélangent souvent ici.",[17,4755,4756,4757,4760,4761,4763],{},"La limite de huit vise les ",[221,4758,4759],{},"socles de prise de courant"," : le nombre de socles simples ou multiples est limité à huit par circuit terminal (",[60,4762,3348],{},"). Un circuit d'éclairage pur n'y est pas soumis.",[17,4765,4766,4767,4770,4771,4774,4775,4777],{},"Dès que socles, appareils d'éclairage et autres appareils fixes partagent le ",[221,4768,4769],{},"même"," circuit terminal, ce sont les prescriptions des circuits de prises qui s'appliquent — et le texte précise alors qu'« un appareil fixe ou un ensemble d'appareils fixes commandé par un appareil de manœuvre commun ",[4772,4773,3121],"span",{}," assimilé à un socle de prise de courant » (",[60,4776,3348],{},"). Quatre spots suspendus à une même chaîne de commande comptent donc, dans un circuit mixte, pour une seule unité et non pour quatre.",[17,4779,4780,4781,729,4784,4786,4787,212],{},"Par ailleurs, pour les unités d'habitation comprenant plus de deux locaux et\u002Fou emplacements, les circuits alimentant les appareils d'éclairage sont ",[221,4782,4783],{},"au moins au nombre de deux circuits distincts",[60,4785,3348],{},"). Un unique circuit d'éclairage pour toute une habitation n'est donc pas un choix de conception mais un manquement. Le décompte dans les circuits mixtes est détaillé dans ",[203,4788,4790],{"href":4789},"\u002Ffr\u002Fblog\u002Fprises-par-circuit","prises par circuit",[12,4792,4794],{"id":4793},"où-peut-on-placer-linterrupteur-dans-une-salle-de-bains","Où peut-on placer l'interrupteur dans une salle de bains ?",[17,4796,4797,4798,4801],{},"Pour les locaux contenant une baignoire et\u002Fou une douche, la ",[60,4799,4800],{},"sous-section 7.1.5.2."," fixe volume par volume ce qui est admis. Pour les organes de commande — dont un interrupteur d'éclairage ordinaire — cela donne :",[21,4803,4804,4814],{},[24,4805,4806],{},[27,4807,4808,4811],{},[30,4809,4810],{},"Volume",[30,4812,4813],{},"Dispositif de commande admis ?",[43,4815,4816,4824,4832],{},[27,4817,4818,4821],{},[48,4819,4820],{},"volume 0",[48,4822,4823],{},"Non admis, sauf les dispositifs faisant partie des appareils fixes admis dans ce volume et alimentés en TBTS, source hors volumes 0 et 1 (point b.)",[27,4825,4826,4829],{},[48,4827,4828],{},"volume 1",[48,4830,4831],{},"Uniquement les dispositifs de commande alimentés en TBTS, source hors volumes 0 et 1 (point c., 4.)",[27,4833,4834,4837],{},[48,4835,4836],{},"volume 2",[48,4838,4839],{},"Les dispositifs de commande alimentés en basse tension sont admis (point d., 5.), à côté de la variante TBTS (point d., 4.)",[17,4841,4842,4843,212],{},"Un va-et-vient 230 V se place donc hors des volumes 0 et 1. L'interrupteur à tirette au plafond est une solution courante et dispose de son propre symbole au tableau 2.23 (« interrupteur unipolaire à tirette »), mais il n'échappe pas aux règles de volumes : c'est l'appareil lui-même qui doit se trouver dans un volume admis. Les volumes et les règles de canalisations associées sont développés dans ",[203,4844,4845],{"href":2927},"câbles de salle de bains et zones RGIE",[12,4847,4849],{"id":4848},"quand-la-domotique-remplace-t-elle-le-montage-à-permutateurs","Quand la domotique remplace-t-elle le montage à permutateurs ?",[17,4851,4852],{},"Dès qu'un même point lumineux doit être commandé depuis de nombreux endroits et selon plusieurs ambiances, une solution sur bus devient plus praticable qu'un montage à permutateurs qui s'allonge. Le RGIE lui consacre une rubrique propre au tableau 2.23 : la rubrique J, « Domotique ». L'unité de commande y est représentée par un rectangle en deux parties — en bas le symbole de base (par exemple un interrupteur, ou un socle avec interrupteur), en haut le type de commande de l'unité.",[17,4854,4855,4856,4859],{},"Ce que la domotique ne fait pas disparaître : tout appareil d'utilisation ou machine électrique est manœuvré par un dispositif de commande, et ce dispositif reste nécessaire même lorsque le fonctionnement dépend d'un relais, d'un thermostat ou de tout autre organe analogue (",[60,4857,4858],{},"sous-section 5.3.3.2. point d.","). L'actionneur au tableau ne remplace pas le dispositif de commande exigé : il en est un. Ce qui change, c'est le dessin — vous documentez une unité de commande avec son type de commande au lieu de trois permutateurs en série.",[17,4861,4862,4863,212],{},"Les critères de choix et les pièges des installations mixtes sont traités dans ",[203,4864,4866],{"href":4865},"\u002Ffr\u002Fblog\u002Fdomotique-rgie","domotique et RGIE",[12,4868,4870],{"id":4869},"comment-la-chaîne-de-commande-se-construit-elle-dans-planelec-et-que-change-t-elle-au-schéma","Comment la chaîne de commande se construit-elle dans PlanElec, et que change-t-elle au schéma ?",[17,4872,4873,4874,4877],{},"Dans le plan d'étage, l'outil ",[221,4875,4876],{},"Chaîne de commande"," relie un interrupteur aux luminaires qu'il commande. PlanElec peut proposer une chaîne pour les interrupteurs et luminaires libres d'un local ; une chaîne valide contient au moins un interrupteur et un luminaire, et un appareil ne peut appartenir simultanément à deux chaînes. La chaîne reste cohérente à l'échelle du projet lorsqu'elle traverse plusieurs niveaux ; chaque étage n'affiche que ses tronçons locaux et les marqueurs de continuation.",[17,4879,1759,4880,4883,4884,4887],{},[221,4881,4882],{},"fonction de commande"," se déduit de la chaîne : un interrupteur donne un allumage simple, deux interrupteurs deviennent des va-et-vient aux deux extrémités, et à partir de trois le premier et le dernier restent des va-et-vient tandis que les intermédiaires deviennent des permutateurs. La ",[221,4885,4886],{},"polarité"," se choisit séparément — les deux propriétés ne sont combinées qu'au moment du tracé. À partir de trois points de commande, la variante bipolaire n'est pas représentée, faute de permutateur bipolaire dans le jeu de symboles RGIE ; la combinaison est alors dessinée en unipolaire.",[17,4889,4890,4891,4893],{},"Les boutons-poussoirs, les gradateurs et le double allumage ne sont volontairement ",[221,4892,1095],{}," déduits automatiquement. Le double allumage reste disponible comme choix manuel, précisément parce qu'il décrit deux circuits séparés depuis un seul endroit : vous affectez chaque luminaire délibérément au canal A ou B.",[17,4895,4896],{},"Depuis la mise à jour du 30 août 2026, la liaison entre un interrupteur et ses points lumineux est conservée durablement et met à jour le schéma unifilaire dès que les appareils sont affectés à un circuit. Les luminaires pas encore placés restent dans le même groupe de commande et rejoignent automatiquement la chaîne au moment de leur placement. L'éclairage automatique ne complète que les points lumineux manquants — par tranche de 8 m² entamée, et de 6 m² en cuisine et en salle de bains.",[17,4898,4899,4900,212],{},"Le maniement pas à pas est décrit dans le guide ",[203,4901,4902],{"href":1868},"commandes, circuits et chemins de câbles",[12,4904,4905],{"id":3125},"Ce que l'autocontrôle RGIE ne fait pas sur ce point",[17,4907,4908],{},"L'autocontrôle est indicatif et n'évalue que les règles prises en charge, à partir des données saisies. Concrètement, pour les interrupteurs :",[711,4910,4911,4918,4923,4928,4935],{},[714,4912,4913,4914,4917],{},"Il vérifie la ",[221,4915,4916],{},"plausibilité"," d'un groupe de commande : un groupe doit contenir au moins un interrupteur et au moins une charge commandée. Un groupe sans interrupteur, sans charge ou réduit à un seul élément est signalé.",[714,4919,1139,4920,4922],{},[221,4921,1095],{}," que le montage choisi correspond à la commande voulue. Deux va-et-vient placés dans deux pièces différentes forment une chaîne techniquement valide et rarement pertinente.",[714,4924,1139,4925,4927],{},[221,4926,1095],{}," qu'un interrupteur unipolaire est bien raccordé sur la phase et non sur le neutre. Cela ne ressort pas d'un dessin et doit être constaté hors tension, sur place.",[714,4929,4930,4931,4934],{},"Un ",[221,4932,4933],{},"télérupteur",", un gradateur modulaire, une minuterie d'escalier ou un interrupteur crépusculaire ne sont pas dessinés dans le schéma unifilaire actuel. Ils ne disparaissent pas en silence : avant l'export, PlanElec les signale explicitement comme « modules de tableau non représentables » à vérifier ou à supprimer.",[714,4936,1162,4937,3169,4939,4941],{},[221,4938,1165],{},[221,4940,1165],{}," contrôle. L'appréciation officielle relève exclusivement d'un organisme agréé.",[12,4943,4945],{"id":4944},"à-lire-aussi","À lire aussi",[711,4947,4948,4954,4959,4963],{},[714,4949,4950],{},[203,4951,4953],{"href":4952},"\u002Ffr\u002Fblog\u002Fsymboles-electriques-rgie","Les symboles RGIE pour les deux documents",[714,4955,4956],{},[203,4957,4958],{"href":3283},"Réaliser un schéma unifilaire étape par étape",[714,4960,4961],{},[203,4962,1967],{"href":1966},[714,4964,4965],{},[203,4966,4967],{"href":4865},"Domotique et RGIE",[17,4969,4970],{},[203,4971,4972],{"href":1204},"Ouvrir PlanElec et enregistrer vos chaînes de commande →",[17,4974,4975],{},[60,4976,4977],{},"Référence : RGIE Livre 1 V06 — chapitre 2.13 et tableau 2.23, sous-sections 3.1.2.1., 3.1.2.2., 3.1.2.3., 5.1.6.2., 5.2.1.2. avec le tableau 5.1., 5.3.3.2., 5.3.5.2. et 7.1.5.2. Le texte officiel, l'état réel de l'installation et le contrôle de l'organisme agréé restent déterminants.",{"title":1212,"searchDepth":1213,"depth":1213,"links":4979},[4980,4981,4982,4983,4984,4985,4986,4987,4988,4989,4990,4991],{"id":4439,"depth":1213,"text":4440},{"id":4590,"depth":1213,"text":4591},{"id":4617,"depth":1213,"text":4618},{"id":4655,"depth":1213,"text":4656},{"id":4703,"depth":1213,"text":4704},{"id":4728,"depth":1213,"text":4729},{"id":4749,"depth":1213,"text":4750},{"id":4793,"depth":1213,"text":4794},{"id":4848,"depth":1213,"text":4849},{"id":4869,"depth":1213,"text":4870},{"id":3125,"depth":1213,"text":4905},{"id":4944,"depth":1213,"text":4945},"Le nombre de points de commande détermine le montage. Symboles du tableau 2.23, conducteurs par variante, repérage sur le plan de position et frontière avec la domotique — avec la référence RGIE en regard de chaque affirmation.",{},"\u002Fblog\u002Fswitch-types-single-line-diagram.fr","11 min",{"title":4433,"description":4992},"va-et-vient-permutateur-schema-unifilaire","blog\u002Fswitch-types-single-line-diagram.fr",[1242,1243,4518,4611,4502,1248,2003,5000,1249],"éclairage","QEWY-3GMNabV9vFVbdW5193tdGMVUuTVZPPhnrLkSuY",{"id":5003,"title":5004,"articleId":5005,"body":5006,"category":1228,"date":5432,"description":5433,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":5434,"navigation":1234,"path":5435,"publishDate":5432,"readTime":5436,"refreshInterval":1237,"seo":5437,"slug":5438,"stem":5439,"tags":5440,"__hash__":5444},"blog\u002Fblog\u002Farei-electrical-symbols.fr.md","Symboles électriques du RGIE : guide pour unifilaire et plan de position","arei-electrical-symbols",{"type":9,"value":5007,"toc":5417},[5008,5012,5023,5026,5030,5033,5049,5052,5056,5059,5174,5177,5181,5184,5195,5198,5202,5205,5219,5222,5226,5229,5236,5240,5243,5260,5263,5267,5290,5294,5297,5300,5303,5307,5310,5313,5339,5357,5361,5364,5367,5376,5380,5383,5386,5390,5407,5412],[12,5009,5011],{"id":5010},"réponse-directe-le-tableau-223-est-la-référence-pas-une-liste-fermée","Réponse directe : le tableau 2.23 est la référence, pas une liste fermée",[17,5013,5014,5015,5018,5019,5022],{},"Pour le schéma unifilaire et le plan de position d'une installation domestique, le RGIE Livre 1 renvoie aux symboles graphiques du ",[221,5016,5017],{},"chapitre 2.13, tableau 2.23",". Le texte précise que cette liste est ",[221,5020,5021],{},"non limitative",". Lorsqu'aucun signe ne correspond à un équipement, un autre symbole clairement identifiable peut être utilisé si sa signification est définie dans la légende des documents.",[17,5024,5025],{},"Cette souplesse n'autorise pas des pictogrammes ambigus. Le signe doit rester compréhensible sur tout le dossier et les caractéristiques techniques obligatoires ne disparaissent pas. Le présent guide couvre le domestique selon le Livre 1 V06 ; les installations non domestiques ou certains schémas multifilaires demandent d'autres symboles normalisés et davantage d'informations.",[12,5027,5029],{"id":5028},"symbole-caractéristique-et-référence-trois-fonctions","Symbole, caractéristique et référence : trois fonctions",[17,5031,5032],{},"La sous-section 3.1.2.1 relie les signes du chapitre 2.13 aux plans domestiques. Pour lire correctement un document, distinguez :",[5034,5035,5036,5043,5046],"ol",{},[714,5037,5038,5039,5042],{},"le ",[221,5040,5041],{},"symbole de base",", qui identifie la famille de matériel ;",[714,5044,5045],{},"les valeurs et mentions, qui décrivent ses propriétés électriques ;",[714,5047,5048],{},"la lettre de circuit et le numéro, qui relient la topologie à la position réelle.",[17,5050,5051],{},"Un dessin de DDR sans type ni courant assigné est incomplet. Une ligne entre disjoncteur et prise ne donne ni nature, ni section, ni nombre de conducteurs, ni mode de pose. Un point sur le plan qui ne porte pas la même référence que l'unifilaire ne peut pas être rapproché de façon fiable du circuit.",[12,5053,5055],{"id":5054},"les-familles-du-tableau-223","Les familles du tableau 2.23",[17,5057,5058],{},"Ce tableau résume la signification ; la géométrie officielle de chaque signe reste celle du RGIE.",[21,5060,5061,5074],{},[24,5062,5063],{},[27,5064,5065,5068,5071],{},[30,5066,5067],{},"Famille",[30,5069,5070],{},"Exemples",[30,5072,5073],{},"Rôle documentaire",[43,5075,5076,5087,5098,5108,5119,5130,5141,5152,5163],{},[27,5077,5078,5081,5084],{},[48,5079,5080],{},"Signes généraux",[48,5082,5083],{},"DC, AC, monophasé, triphasé",[48,5085,5086],{},"préciser la nature du courant",[27,5088,5089,5092,5095],{},[48,5090,5091],{},"Ensembles et boîtes",[48,5093,5094],{},"tableau, boîte générale, connexion\u002Fdérivation, coffret de branchement",[48,5096,5097],{},"représenter les nœuds de l'installation",[27,5099,5100,5102,5105],{},[48,5101,93],{},[48,5103,5104],{},"souterraine, aérienne, apparente, encastrée, sous conduit, nombre de conducteurs",[48,5106,5107],{},"décrire constitution et pose",[27,5109,5110,5113,5116],{},[48,5111,5112],{},"Protections",[48,5114,5115],{},"fusible, disjoncteur, DDR, terre",[48,5117,5118],{},"montrer les fonctions de protection",[27,5120,5121,5124,5127],{},[48,5122,5123],{},"Interrupteurs et commandes",[48,5125,5126],{},"va-et-vient, permutateur, poussoir, variateur, détecteur",[48,5128,5129],{},"relier commande et point commandé",[27,5131,5132,5135,5138],{},[48,5133,5134],{},"Prises",[48,5136,5137],{},"simple, multiple, avec terre, commandée, données",[48,5139,5140],{},"distinguer les points de raccordement",[27,5142,5143,5146,5149],{},[48,5144,5145],{},"Récepteurs",[48,5147,5148],{},"éclairage, chauffage, appareil ménager, moteur, borne de recharge",[48,5150,5151],{},"identifier les charges fixes ou localisées",[27,5153,5154,5157,5160],{},[48,5155,5156],{},"Sources et convertisseurs",[48,5158,5159],{},"transformateur, cellule solaire, redresseur, onduleur, DC\u002FDC",[48,5161,5162],{},"documenter production et conversion",[27,5164,5165,5168,5171],{},[48,5166,5167],{},"Domotique",[48,5169,5170],{},"signe de base complété par commande locale, sans fil, programmée ou par capteur",[48,5172,5173],{},"associer fonction électrique et mode de commande",[17,5175,5176],{},"Le tableau n'est pas une liste de matériel à installer. Un signe officiel ne prouve ni le choix, ni le raccordement, ni le dimensionnement correct de l'équipement.",[12,5178,5180],{"id":5179},"canalisation-la-ligne-ne-suffit-jamais","Canalisation : la ligne ne suffit jamais",[17,5182,5183],{},"Le schéma unifilaire indique au minimum le type, la section, le nombre de conducteurs et le mode de pose. Le tableau 2.23 fournit des signes pour une canalisation apparente ou encastrée, en conduit, aérienne ou souterraine, ainsi que des exemples combinant ces données.",[17,5185,5186,5187,5190,5191,5194],{},"Une notation telle que ",[4068,5188,5189],{},"3G2,5"," indique trois conducteurs, dont le conducteur vert-jaune de protection, de 2,5 mm². Une écriture avec ",[4068,5192,5193],{},"×"," ne porte pas automatiquement la même information sur le PE. La représentation doit correspondre à la pose réelle, et non à la solution graphique la plus courte.",[17,5196,5197],{},"Le symbole ne réalise pas le calcul. Courant admissible, mode de pose, groupement, température, chute de tension, boucle de défaut et protection doivent être vérifiés séparément.",[12,5199,5201],{"id":5200},"protections-lire-le-signe-avec-ses-valeurs","Protections : lire le signe avec ses valeurs",[17,5203,5204],{},"Le RGIE différencie fusible, disjoncteur et dispositif différentiel. Les informations associées donnent son sens au symbole :",[711,5206,5207,5210,5213,5216],{},[714,5208,5209],{},"courant assigné et courbe du disjoncteur ;",[714,5211,5212],{},"type, sensibilité différentielle et courant assigné du DDR ;",[714,5214,5215],{},"fonctions identifiées pour un appareil à plusieurs déclencheurs ;",[714,5217,5218],{},"connexion de terre réellement présente.",[17,5220,5221],{},"La seule mention “30 mA” ne précise ni type A\u002FF\u002FB, ni instantanéité ou sélectivité. “20 A” sans caractéristique et sans canalisation associée ne suffit pas. Relevez les données du matériel installé et du calcul, jamais d'un plan générique.",[12,5223,5225],{"id":5224},"une-référence-identique-sur-les-deux-plans","Une référence identique sur les deux plans",[17,5227,5228],{},"Chaque circuit élémentaire reçoit une lettre majuscule sur l'unifilaire. Points lumineux, socles et unités de commande sont numérotés dans l'ordre à partir de la protection contre les surintensités. Le plan de position reprend lettre et numéro.",[17,5230,5231,5232,5235],{},"Ainsi, ",[4068,5233,5234],{},"D2"," doit désigner le même élément sur chaque document. Un interrupteur est repéré par son circuit et le numéro du point ou appareil commandé. Cette règle évite qu'un symbole spatial soit présent sans relation électrique explicite. Prise multiple, prise commandée et prise de données ne devraient pas partager un signe générique lorsque leur différence décrit l'installation.",[12,5237,5239],{"id":5238},"créer-un-symbole-avec-légende","Créer un symbole avec légende",[17,5241,5242],{},"Lorsqu'aucun signe officiel n'est adapté :",[5034,5244,5245,5248,5251,5254,5257],{},[714,5246,5247],{},"vérifier si un symbole général complété d'un libellé suffit ;",[714,5249,5250],{},"sinon choisir une forme simple et non confondable ;",[714,5252,5253],{},"définir clairement forme, abréviation et fonction dans la légende ;",[714,5255,5256],{},"conserver le même signe dans tout le dossier ;",[714,5258,5259],{},"placer les propriétés techniques sur l'unifilaire ou dans le dossier.",[17,5261,5262],{},"Un logo commercial ne décrit généralement pas une fonction électrique. Un signe personnel non défini reste ambigu, même si son auteur le comprend.",[12,5264,5266],{"id":5265},"erreurs-fréquentes","Erreurs fréquentes",[711,5268,5269,5272,5275,5278,5281,5284,5287],{},[714,5270,5271],{},"importer un symbole DIN, IEC ou logiciel sans vérifier son sens dans le document ;",[714,5273,5274],{},"employer le même dessin pour prise simple, multiple, commandée et données ;",[714,5276,5277],{},"oublier section, conducteurs ou mode de pose ;",[714,5279,5280],{},"indiquer 30 mA sans type et courant assigné du DDR ;",[714,5282,5283],{},"utiliser des références différentes entre unifilaire et position ;",[714,5285,5286],{},"réduire le photovoltaïque à un panneau sans source, onduleur ni caractéristiques ;",[714,5288,5289],{},"styliser le dessin jusqu'à rendre le signe ou la légende méconnaissable.",[12,5291,5293],{"id":5292},"vérifier-la-lisibilité-du-pdf-final","Vérifier la lisibilité du PDF final",[17,5295,5296],{},"Un bon symbole peut devenir inutilisable après mise en page. Ouvrez l'export à une taille de lecture normale : bord de page ou trait coupe-t-il une valeur, les références restent-elles lisibles, les prises ordinaires et commandées sont-elles encore distinctes, chaque texte est-il rattaché au bon appareil ?",[17,5298,5299],{},"Ne faites pas dépendre le sens de la seule couleur : le dossier peut être imprimé ou copié en noir et blanc. Forme, texte et référence doivent suffire. La légende figure sur les pages concernées ou est référencée sans ambiguïté dans le même jeu documentaire. Les abréviations restent constantes.",[17,5301,5302],{},"Comparez aussi les références des deux plans. Ce contrôle ne remplace aucune mesure, mais repère code doublé, récepteur absent ou symbole copié au mauvais endroit avant remise du dossier.",[12,5304,5306],{"id":5305},"une-méthode-reproductible-du-relevé-à-la-légende","Une méthode reproductible, du relevé à la légende",[17,5308,5309],{},"Ne commencez pas par dessiner. Établissez d'abord un inventaire où chaque point réel reçoit local, circuit, numéro d'ordre, fonction et caractéristiques à inscrire près du signe. Choisissez ensuite le signe de base du tableau 2.23. Cette séquence évite qu'une icône ressemblante impose une fonction erronée. Un ventilateur fixe, une prise et une boîte de connexion peuvent dépendre du même circuit, mais restent trois matériels distincts.",[17,5311,5312],{},"Relisez chaque entrée en quatre passages :",[5034,5314,5315,5321,5327,5333],{},[714,5316,5317,5320],{},[221,5318,5319],{},"Signe de base :"," la famille est-elle correcte, par exemple protection, prise, luminaire, source ou machine fixe ?",[714,5322,5323,5326],{},[221,5324,5325],{},"Caractéristiques :"," polarité, courant assigné, sensibilité différentielle, type de canalisation, nombre et section des conducteurs sont-ils présents quand ils sont nécessaires à la lecture ?",[714,5328,5329,5332],{},[221,5330,5331],{},"Repère :"," le point du plan de position reprend-il exactement la lettre et le numéro attribués sur l'unifilaire ?",[714,5334,5335,5338],{},[221,5336,5337],{},"Légende :"," chaque combinaison propre au projet est-elle définie une fois et facilement retrouvée sur chaque feuille concernée ?",[17,5340,5341,5342,5345,5346,2020,5349,5352,5353,5356],{},"Prenons le circuit ",[4068,5343,5344],{},"K"," : il part après un DDR identifié et une protection de 20 A, continue par un câble 3G2,5 documenté et alimente trois raccordements fixes. La protection porte ses valeurs, le câble ses caractéristiques et les raccordements les repères ",[4068,5347,5348],{},"K1",[4068,5350,5351],{},"K3",". Un seul pictogramme « cuisine » ne conserverait pas cette structure. Si ",[4068,5354,5355],{},"K2"," change ensuite de fonction, gardez le repère stable et mettez à jour signe, désignation et caractéristiques sur les deux plans.",[12,5358,5360],{"id":5359},"traiter-les-cas-limites-sans-masquer-linformation","Traiter les cas limites sans masquer l'information",[17,5362,5363],{},"Pour un appareil combiné, déterminez quelles fonctions électriques doivent rester visibles pour le contrôle et la maintenance. Un bloc de prises peut être regroupé si quantité et commande ne prêtent pas à confusion. Un actionneur intelligent à plusieurs sorties demandera plutôt un signe de base, un code de légende et un renvoi vers sa fiche technique. La légende ne permet jamais de faire disparaître canalisation, protection ou source.",[17,5365,5366],{},"Versionnez les signes propres au projet comme les autres données de l'installation. Après une modification, notez date et repères concernés, puis vérifiez toutes les feuilles. Ne conservez pas une ancienne légende à côté des PDF actuels dans le dossier remis. En cas de doute, faites valider la représentation par le professionnel responsable et, si nécessaire, par l'organisme agréé avant l'exécution.",[17,5368,1759,5369,5375],{},[203,5370,5374],{"href":5371,"rel":5372},"https:\u002F\u002Feconomie.fgov.be\u002Ffr\u002Fpublications\u002Freglement-general-sur-les",[5373],"nofollow","publication officielle du RGIE Livre 1"," reste la source primaire. Vérifiez-y l'édition applicable à la date du document. Les bibliothèques d'icônes de fabricants ou les signes empruntés à une norme étrangère ne remplacent ni le tableau 2.23 ni les règles belges relatives aux plans.",[12,5377,5379],{"id":5378},"le-catalogue-planelec-sans-promesse-excessive","Le catalogue PlanElec, sans promesse excessive",[17,5381,5382],{},"PlanElec propose un catalogue de symboles pour la documentation électrique belge. Les composants saisis peuvent alimenter schéma unifilaire et plan de position, puis être exportés en PDF. L'auto-contrôle indicatif ne couvre que les règles prises en charge pour lesquelles les données nécessaires existent.",[17,5384,5385],{},"Le catalogue ne prouve pas que tout équipement spécial est modélisé ou contrôlé. Vérifiez type réel, valeurs, références et emplacement. Un symbole bien rendu n'est ni un dimensionnement, ni une déclaration de conformité RGIE, ni un rapport d'organisme agréé.",[12,5387,5389],{"id":5388},"articles-liés","Articles liés",[711,5391,5392,5397,5402],{},[714,5393,5394],{},[203,5395,5396],{"href":4091},"Schéma unifilaire ou plan de position : différence et complémentarité",[714,5398,5399],{},[203,5400,5401],{"href":3283},"Créer un schéma unifilaire étape par étape",[714,5403,5404],{},[203,5405,5406],{"href":1579},"Section de câble et protection",[17,5408,5409],{},[203,5410,5411],{"href":1204},"Ouvrir PlanElec pour saisir les symboles et exporter les deux plans →",[17,5413,5414],{},[60,5415,5416],{},"Référence : RGIE Livre 1 V06, chapitre 2.13 et sous-sections 3.1.2.1 à 3.1.2.3. Le tableau 2.23 officiel et l'installation réelle restent déterminants.",{"title":1212,"searchDepth":1213,"depth":1213,"links":5418},[5419,5420,5421,5422,5423,5424,5425,5426,5427,5428,5429,5430,5431],{"id":5010,"depth":1213,"text":5011},{"id":5028,"depth":1213,"text":5029},{"id":5054,"depth":1213,"text":5055},{"id":5179,"depth":1213,"text":5180},{"id":5200,"depth":1213,"text":5201},{"id":5224,"depth":1213,"text":5225},{"id":5238,"depth":1213,"text":5239},{"id":5265,"depth":1213,"text":5266},{"id":5292,"depth":1213,"text":5293},{"id":5305,"depth":1213,"text":5306},{"id":5359,"depth":1213,"text":5360},{"id":5378,"depth":1213,"text":5379},{"id":5388,"depth":1213,"text":5389},"2026-08-29","Comprendre le tableau 2.23, les informations à ajouter aux symboles et la règle de légende quand aucun signe officiel ne décrit exactement un équipement domestique.",{},"\u002Fblog\u002Farei-electrical-symbols.fr","9 min",{"title":5004,"description":5433},"symboles-electriques-rgie","blog\u002Farei-electrical-symbols.fr",[1243,1242,5441,5442,1248,2003,5443,1249],"symboles électriques","tableau 2.23","légende","uKW2FGShS_0GYbwWR7IGZKaHdFafNKTfhsIWmWTD7Hk",{"id":5446,"title":5447,"articleId":5448,"body":5449,"category":5859,"date":5432,"description":5860,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":5861,"navigation":1234,"path":5862,"publishDate":5432,"readTime":5863,"refreshInterval":1237,"seo":5864,"slug":5865,"stem":5866,"tags":5867,"__hash__":5873},"blog\u002Fblog\u002Fheat-pump-single-line-diagram.fr.md","Pompe à chaleur sur le schéma unifilaire : circuit et données à représenter","heat-pump-single-line-diagram",{"type":9,"value":5450,"toc":5837},[5451,5458,5461,5465,5468,5494,5497,5501,5504,5507,5516,5519,5525,5538,5542,5545,5571,5578,5582,5585,5602,5610,5614,5617,5637,5644,5648,5659,5676,5683,5685,5690,5693,5697,5700,5704,5707,5711,5714,5718,5721,5741,5744,5748,5751,5754,5758,5761,5764,5767,5771,5774,5777,5797,5800,5804,5807,5813,5817,5825,5829],[17,5452,5453,5454,5457],{},"Une pompe à chaleur ne se résume pas toujours à un seul récepteur. Une unité extérieure, un module intérieur, une résistance d’appoint, des circulateurs, une régulation ou un ballon sanitaire peuvent recevoir des alimentations différentes. Le schéma unifilaire doit décrire cette ",[221,5455,5456],{},"architecture électrique réellement installée",", et non le dessin hydraulique simplifié d’une brochure.",[17,5459,5460],{},"Le RGIE Livre 1 V06 ne prescrit pas un symbole, un disjoncteur ou un type de différentiel unique pour toutes les pompes à chaleur. Les règles générales relatives aux circuits, aux protections, aux canalisations et aux documents s’appliquent avec les instructions électriques du modèle exact. La qualité du schéma dépend donc d’un relevé précis.",[12,5462,5464],{"id":5463},"réunir-les-données-avant-de-dessiner","Réunir les données avant de dessiner",[17,5466,5467],{},"Examinez le tableau, les plaques signalétiques et les notices d’installation. Pour chaque élément alimenté, relevez :",[711,5469,5470,5473,5476,5479,5482,5485,5488,5491],{},[714,5471,5472],{},"la référence et la fonction de l’appareil ;",[714,5474,5475],{},"la tension et le raccordement monophasé ou triphasé ;",[714,5477,5478],{},"le courant nominal et la protection maximale demandée par le constructeur ;",[714,5480,5481],{},"la présence d’un variateur ou d’une électronique inverter ;",[714,5483,5484],{},"les indications relatives au différentiel et aux composantes continues possibles ;",[714,5486,5487],{},"le type de câble, le nombre de conducteurs, la section et le trajet réel ;",[714,5489,5490],{},"l’éventuel interrupteur de proximité ou dispositif de sectionnement ;",[714,5492,5493],{},"les alimentations séparées de l’appoint, de la régulation, d’une pompe ou du ballon.",[17,5495,5496],{},"Une puissance thermique de 8 kW n’est ni la puissance électrique absorbée ni la puissance de raccordement. Le document électrique doit reprendre les grandeurs électriques pertinentes.",[12,5498,5500],{"id":5499},"déterminer-le-nombre-réel-de-circuits","Déterminer le nombre réel de circuits",[17,5502,5503],{},"Un monobloc peut disposer d’une seule alimentation. Un système split peut alimenter séparément les unités extérieure et intérieure. Une résistance intégrée peut partager le bornier principal ou dépendre d’un départ distinct. La commande peut être alimentée par le module intérieur ou par sa propre protection.",[17,5505,5506],{},"Évitez donc de recopier systématiquement :",[5508,5509,5514],"pre",{"className":5510,"code":5512,"language":5513,"meta":1212},[5511],"language-text","Tableau → disjoncteur → pompe à chaleur\n","text",[4068,5515,5512],{"__ignoreMap":1212},[17,5517,5518],{},"Une réalisation peut plutôt présenter cette structure :",[5508,5520,5523],{"className":5521,"code":5522,"language":5513,"meta":1212},[5511],"Tableau principal\n├─ circuit PAC1 → protection → câble → unité extérieure\u002Finverter\n├─ circuit PAC2 → protection → câble → unité intérieure\u002Frégulation\n└─ circuit PAC3 → protection → câble → appoint électrique\n",[4068,5524,5522],{"__ignoreMap":1212},[17,5526,5527,5528,63,5531,207,5534,5537],{},"Les repères ",[4068,5529,5530],{},"PAC1",[4068,5532,5533],{},"PAC2",[4068,5535,5536],{},"PAC3"," sont des exemples. Utilisez les lettres de circuit du projet et conservez-les sur le plan de situation.",[12,5539,5541],{"id":5540},"informations-à-placer-sur-chaque-départ","Informations à placer sur chaque départ",[17,5543,5544],{},"La chaîne entre le tableau et le récepteur doit pouvoir être relue sans deviner. Indiquez au minimum :",[5034,5546,5547,5550,5553,5556,5559,5562,5565,5568],{},[714,5548,5549],{},"le repère du circuit ;",[714,5551,5552],{},"le type, le nombre de pôles et le courant assigné de la protection contre les surintensités ;",[714,5554,5555],{},"le différentiel présent, avec sensibilité et type ;",[714,5557,5558],{},"le type de câble ou de conducteur, leur nombre et leur section ;",[714,5560,5561],{},"l’affectation des phases pour une alimentation polyphasée ;",[714,5563,5564],{},"une désignation précise, telle que « pompe à chaleur – unité extérieure » ;",[714,5566,5567],{},"la puissance électrique ou le courant nominal utile ;",[714,5569,5570],{},"le sectionneur, contacteur ou dispositif de gestion de puissance s’il fait partie de l’installation fixe.",[17,5572,5573,5574,5577],{},"Le choix de la ",[203,5575,5576],{"href":1579},"section de câble et du disjoncteur"," exige davantage que la puissance nominale. Longueur, mode de pose, groupement, température, chute de tension, courant de court-circuit et notice constructeur interviennent dans le dimensionnement complet.",[12,5579,5581],{"id":5580},"différentiel-partir-du-modèle-réel","Différentiel : partir du modèle réel",[17,5583,5584],{},"L’électronique de puissance du compresseur peut produire des formes de courant de défaut différentes de celles d’une charge résistive. Cela ne signifie ni qu’un type B est toujours obligatoire, ni qu’un type A convient toujours. Vérifiez ensemble :",[711,5586,5587,5590,5593,5596,5599],{},[714,5588,5589],{},"la notice obligatoire du modèle et de ses options ;",[714,5591,5592],{},"la présence éventuelle d’une détection interne du courant continu résiduel ;",[714,5594,5595],{},"le schéma de mise à la terre et les conditions de coupure ;",[714,5597,5598],{},"la sélectivité avec les différentiels placés en amont ;",[714,5600,5601],{},"les courants de fuite cumulés des autres équipements.",[17,5603,5604,5605,5609],{},"Le guide ",[203,5606,5608],{"href":5607},"\u002Ffr\u002Fblog\u002Fdifferentiel-type-a-vs-type-b","différentiel type A ou type B"," sépare forme d’onde, immunité renforcée et sélectivité. Le schéma doit représenter l’appareil installé et ses caractéristiques, pas une recommandation générique.",[12,5611,5613],{"id":5612},"choisir-un-symbole-et-définir-la-légende","Choisir un symbole et définir la légende",[17,5615,5616],{},"Le tableau 2.23 du RGIE Livre 1 V06 n’est pas exhaustif. Lorsqu’aucun symbole standard n’exprime clairement la configuration, un signe non ambigu peut être utilisé à condition d’être défini dans la légende. Par exemple :",[711,5618,5619,5625,5631],{},[714,5620,5621,5624],{},[4068,5622,5623],{},"PAC-E"," : unité extérieure ;",[714,5626,5627,5630],{},[4068,5628,5629],{},"PAC-I"," : unité intérieure ;",[714,5632,5633,5636],{},[4068,5634,5635],{},"AE"," : appoint électrique.",[17,5638,5639,5640,5643],{},"La signification doit rester identique dans tout le dossier. Ne réutilisez pas la même abréviation pour une pompe de circulation. La page ",[203,5641,5642],{"href":4952},"symboles électriques du RGIE"," détaille la règle de légende.",[12,5645,5647],{"id":5646},"relier-unifilaire-et-plan-de-situation","Relier unifilaire et plan de situation",[17,5649,5650,5651,5654,5655,5658],{},"Le schéma unifilaire explique ",[221,5652,5653],{},"comment"," la pompe à chaleur est alimentée et protégée. Le plan de situation indique ",[221,5656,5657],{},"où"," se trouvent les équipements électriques fixes. Selon le chantier, localisez :",[711,5660,5661,5664,5667,5670,5673],{},[714,5662,5663],{},"les unités extérieure et intérieure ;",[714,5665,5666],{},"l’interrupteur de proximité ou le sectionneur ;",[714,5668,5669],{},"le coffret de commande ou le tableau secondaire ;",[714,5671,5672],{},"la résistance d’appoint fixe ;",[714,5674,5675],{},"les cheminements fixes utiles à la compréhension ou à la maintenance.",[17,5677,5678,5679,5682],{},"Chaque élément reprend le même repère de circuit que sur l’unifilaire. Un schéma hydraulique peut compléter le dossier mais ne remplace pas les plans électriques. Consultez ",[203,5680,5681],{"href":4091},"schéma unifilaire ou plan de situation"," pour leur articulation.",[12,5684,5266],{"id":5265},[5686,5687,5689],"h3",{"id":5688},"écrire-seulement-pac-8-kw","Écrire seulement « PAC 8 kW »",[17,5691,5692],{},"Cette valeur est souvent thermique. Elle ne renseigne ni l’alimentation, ni la protection, ni la canalisation électrique.",[5686,5694,5696],{"id":5695},"oublier-lappoint-électrique","Oublier l’appoint électrique",[17,5698,5699],{},"Une résistance peut modifier fortement la pointe électrique et disposer d’un départ propre. Elle doit apparaître lorsqu’elle appartient à l’installation fixe.",[5686,5701,5703],{"id":5702},"copier-la-protection-dun-autre-modèle","Copier la protection d’un autre modèle",[17,5705,5706],{},"Deux appareils de puissance thermique comparable peuvent avoir une alimentation et des exigences différentielles différentes.",[5686,5708,5710],{"id":5709},"livrer-le-projet-au-lieu-de-las-built","Livrer le projet au lieu de l’as-built",[17,5712,5713],{},"Les phases, options et trajets peuvent évoluer sur chantier. Le schéma, les étiquettes du tableau et le dossier doivent être réconciliés après la pose.",[12,5715,5717],{"id":5716},"vérification-documentaire-finale","Vérification documentaire finale",[17,5719,5720],{},"Avant la remise du dossier, vérifiez :",[711,5722,5723,5726,5729,5732,5735,5738],{},[714,5724,5725],{},"concordance entre plaques signalétiques et noms du schéma ;",[714,5727,5728],{},"présence de toutes les unités et alimentations auxiliaires ;",[714,5730,5731],{},"correspondance des pôles, calibres et différentiels avec le matériel posé ;",[714,5733,5734],{},"traçabilité des câbles et des phases ;",[714,5736,5737],{},"mêmes repères sur tableau, unifilaire et plan de situation ;",[714,5739,5740],{},"conservation des notices et des modifications dans le dossier de l’installation.",[17,5742,5743],{},"Cette revue ne remplace pas le calcul électrique, la réalisation par une personne compétente ni le contrôle réglementaire par un organisme agréé.",[12,5745,5747],{"id":5746},"quand-réviser-à-nouveau-le-schéma","Quand réviser à nouveau le schéma",[17,5749,5750],{},"Une mise à jour n’est pas réservée au remplacement complet de la pompe à chaleur. Elle est aussi nécessaire lorsqu’un appoint est activé, qu’une option électrique est ajoutée, qu’un modèle monophasé devient triphasé ou qu’une régulation externe est raccordée à demeure. Toute modification du différentiel, du disjoncteur, du câble ou des phases doit rejoindre l’as-built.",[17,5752,5753],{},"Comparez les données avant\u002Faprès, les conducteurs disponibles, les protections, les prescriptions du nouveau modèle, les positions et les notices. Un circuit déconnecté mais encore présent doit être identifié sans ambiguïté. Laisser apparaître un appareil hors service comme actif est aussi trompeur qu’omettre une résistance nouvellement raccordée.",[12,5755,5757],{"id":5756},"exemple-groupe-extérieur-module-intérieur-et-appoint","Exemple : groupe extérieur, module intérieur et appoint",[17,5759,5760],{},"Imaginons une installation composée d'un groupe extérieur triphasé, d'un module intérieur alimenté séparément et d'un appoint électrique. Ne la réduisez pas immédiatement à un seul bloc. Vérifiez sur le modèle livré et le câblage réel si trois circuits terminaux existent ou si certains éléments sont alimentés depuis le groupe extérieur. Seuls les circuits réellement séparés reçoivent chaîne de protection, canalisation et repère propres.",[17,5762,5763],{},"Pour chaque départ existant, relevez l'absorption électrique maximale dans la documentation contraignante du fabricant, pas la puissance thermique d'une brochure commerciale. Indiquez phases, neutre et conducteur de protection selon le câble posé. Un groupe extérieur triphasé peut côtoyer une commande ou un module intérieur monophasé ; la fonction commune « pompe à chaleur » n'efface pas ces différences. Examinez surtout l'appoint, dont la puissance raccordée et les étages peuvent dépasser largement l'entrée du compresseur.",[17,5765,5766],{},"Placez groupe extérieur, module intérieur, dispositif fixe de sectionnement et appoint séparé à leur emplacement réel sur le plan de position. Ne présentez pas bus, sondes et commandes comme des circuits de puissance. S'ils sont utiles à la maintenance, expliquez-les dans la légende ou la documentation technique sans les confondre avec l'alimentation secteur.",[12,5768,5770],{"id":5769},"tenir-compte-de-la-mise-en-service-et-des-modes-de-fonctionnement","Tenir compte de la mise en service et des modes de fonctionnement",[17,5772,5773],{},"Après mise en service, confrontez le départ dessiné aux plaques, bornes, paramètres installateur et relevés d'essai. Limitation de charge, contact de blocage ou gestion énergétique peuvent modifier le fonctionnement, mais ne remplacent pas automatiquement le dimensionnement et l'analyse des protections. Ne documentez comme hypothèse que les réglages réellement appliqués, protégés contre une modification involontaire et pertinents pour l'étude.",[17,5775,5776],{},"Examinez des situations qu'un cycle normal masque facilement :",[711,5778,5779,5782,5785,5788,5791,5794],{},[714,5780,5781],{},"dégivrage avec appoint simultané ;",[714,5783,5784],{},"mode secours ou cycle sanitaire utilisant la résistance ;",[714,5786,5787],{},"démarrage et comportement du variateur selon le fabricant ;",[714,5789,5790],{},"alimentation distincte d'un chauffage de bac ou de traçage ;",[714,5792,5793],{},"sectionnement sûr pour la maintenance ;",[714,5795,5796],{},"redémarrage après coupure ou délestage.",[17,5798,5799],{},"Cette liste n'impose ni disjoncteur, ni DDR, ni section universels. Elle identifie les données que le concepteur doit résoudre avec la notice exacte et les conditions de pose. Mesures et temps de coupure restent à vérifier sur place.",[12,5801,5803],{"id":5802},"interfaces-avec-pv-batterie-et-gestion-de-charge","Interfaces avec PV, batterie et gestion de charge",[17,5805,5806],{},"Une pompe à chaleur peut recevoir un signal d'autoconsommation sans être électriquement « derrière l'onduleur PV » si la topologie AC dit autre chose. Dessinez les chemins d'énergie selon les raccordements réels et décrivez séparément communications ou contacts smart-grid. En alimentation de secours, vérifiez que la pompe dépend effectivement du tableau secouru et que limites de démarrage et de puissance autorisent ce mode. Un réglage dans une application ne prouve pas le raccordement.",[17,5808,1759,5809,5812],{},[203,5810,5374],{"href":5371,"rel":5811},[5373]," fixe le cadre général des schémas et protections. Valeurs d'entrée, protections externes et variantes de raccordement propres au modèle proviennent de la notice actuelle de l'équipement installé.",[12,5814,5816],{"id":5815},"documenter-dans-planelec","Documenter dans PlanElec",[17,5818,5819,5820,5824],{},"Dans ",[203,5821,5823],{"href":5822},"\u002Ffr\u002F","PlanElec",", vous pouvez rattacher les éléments de la pompe à chaleur aux circuits réellement posés, saisir protections et canalisations, puis exporter schéma unifilaire et plan de situation en PDF. Une légende reste nécessaire pour tout symbole propre au projet. L’auto-contrôle indicatif peut signaler certaines saisies prises en charge ; il ne certifie ni conformité RGIE, ni accord constructeur, et ne produit pas un rapport officiel.",[12,5826,5828],{"id":5827},"sources-et-version-examinée","Sources et version examinée",[17,5830,5831,5832,5836],{},"La base réglementaire est la publication officielle du ",[203,5833,5835],{"href":5371,"rel":5834},[5373],"RGIE Livre 1",", notamment le tableau 2.23 et la partie 3 relative aux plans, complétée par la notice électrique du modèle installé. Version examinée : Livre 1 V06, 29 août 2026.",{"title":1212,"searchDepth":1213,"depth":1213,"links":5838},[5839,5840,5841,5842,5843,5844,5845,5852,5853,5854,5855,5856,5857,5858],{"id":5463,"depth":1213,"text":5464},{"id":5499,"depth":1213,"text":5500},{"id":5540,"depth":1213,"text":5541},{"id":5580,"depth":1213,"text":5581},{"id":5612,"depth":1213,"text":5613},{"id":5646,"depth":1213,"text":5647},{"id":5265,"depth":1213,"text":5266,"children":5846},[5847,5849,5850,5851],{"id":5688,"depth":5848,"text":5689},3,{"id":5695,"depth":5848,"text":5696},{"id":5702,"depth":5848,"text":5703},{"id":5709,"depth":5848,"text":5710},{"id":5716,"depth":1213,"text":5717},{"id":5746,"depth":1213,"text":5747},{"id":5756,"depth":1213,"text":5757},{"id":5769,"depth":1213,"text":5770},{"id":5802,"depth":1213,"text":5803},{"id":5815,"depth":1213,"text":5816},{"id":5827,"depth":1213,"text":5828},"tutorial","Représentez unités extérieure et intérieure, appoint, protections, câble et données constructeur d’une pompe à chaleur selon le RGIE Livre 1 V06.",{},"\u002Fblog\u002Fheat-pump-single-line-diagram.fr","10 min",{"title":5447,"description":5860},"pompe-chaleur-schema-unifilaire","blog\u002Fheat-pump-single-line-diagram.fr",[5868,5869,1242,5870,5871,5872,1249],"Pompe à chaleur","Schéma unifilaire","Circuit","Unité extérieure","Appoint électrique","ZIHSQDwmcxks1-wtt7WBpTQhpiSvAy13uPAisAu1ozE",{"id":5875,"title":5876,"articleId":5877,"body":5878,"category":5859,"date":5432,"description":6247,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":6248,"navigation":1234,"path":6249,"publishDate":5432,"readTime":4995,"refreshInterval":1237,"seo":6250,"slug":6251,"stem":6252,"tags":6253,"__hash__":6257},"blog\u002Fblog\u002Fnew-build-single-line-checklist.fr.md","Schéma unifilaire d’une construction neuve : checklist RGIE fiable","new-build-single-line-checklist",{"type":9,"value":5879,"toc":6228},[5880,5884,5887,5890,5894,5897,5917,5920,5924,5927,5950,5953,5957,5960,5980,5983,5987,5990,5993,5997,6000,6003,6010,6014,6017,6020,6024,6027,6030,6034,6037,6054,6057,6061,6064,6067,6071,6074,6077,6081,6154,6158,6161,6164,6168,6171,6174,6178,6181,6189,6193,6196,6200,6218,6223],[12,5881,5883],{"id":5882},"objectif-décrire-linstallation-réellement-exécutée","Objectif : décrire l'installation réellement exécutée",[17,5885,5886],{},"Pour une nouvelle installation domestique, le responsable de l'exécution établit schéma unifilaire et plan de position. L'unifilaire n'est pas une esquisse que l'on oublie après le chantier. Avant le contrôle de conformité, il doit correspondre aux tableaux, protections, canalisations, circuits, récepteurs et sources réellement placés.",[17,5888,5889],{},"Cette checklist suit le RGIE Livre 1 V06 et vise le cas AC habituel. Les règles applicables depuis le 1er avril 2026 aux systèmes DC mis à la terre constituent un domaine distinct ; les rôles de conducteurs et symboles AC ne peuvent pas y être transposés au hasard.",[12,5891,5893],{"id":5892},"_1-identifier-la-série-de-documents","1. Identifier la série de documents",[17,5895,5896],{},"Avant de tracer les circuits, indiquez :",[711,5898,5899,5902,5905,5908,5911,5914],{},[714,5900,5901],{},"numéro, version et date de version ;",[714,5903,5904],{},"adresse de l'installation ;",[714,5906,5907],{},"nom et qualité du responsable de l'exécution ;",[714,5909,5910],{},"numéro de TVA s'il s'applique ;",[714,5912,5913],{},"emplacements de date et signature ;",[714,5915,5916],{},"tension et nature du courant sur l'unifilaire.",[17,5918,5919],{},"Unifilaire et plan de position partagent la même version. Nom de fichier et date d'export ne suffisent pas après impression ou fusion de PDF. Ne préremplissez ni visa de l'inspecteur ni mention “conforme au RGIE” sur un document de travail. Le visa résulte du contrôle réel.",[12,5921,5923],{"id":5922},"_2-établir-les-données-de-raccordement","2. Établir les données de raccordement",[17,5925,5926],{},"Commencez par les informations du branchement et la réalisation, pas par un modèle générique :",[711,5928,5929,5932,5935,5938,5941,5944,5947],{},[714,5930,5931],{},"alimentation mono- ou triphasée ;",[714,5933,5934],{},"tension nominale et AC\u002FDC ;",[714,5936,5937],{},"présence du neutre et du conducteur de protection ;",[714,5939,5940],{},"compteur et organisation du raccordement ;",[714,5942,5943],{},"protection de branchement et interrupteur-sectionneur principal ;",[714,5945,5946],{},"réseau et mise à la terre nécessaires à l'étude des protections ;",[714,5948,5949],{},"sources ou transformateurs supplémentaires.",[17,5951,5952],{},"Une prise 230 V ne prouve pas si le bâtiment reçoit 3×400 V+N ou 3×230 V. Une mauvaise hypothèse affecte pôles, neutre, câblage des DDR et récepteurs. Contrat, tableau et mesures doivent se confirmer.",[12,5954,5956],{"id":5955},"_3-représenter-toute-la-chaîne-de-protection","3. Représenter toute la chaîne de protection",[17,5958,5959],{},"Incluez tableau principal et tableaux divisionnaires avec leurs alimentations. Chaque circuit terminal reste traçable depuis l'origine. Relevez selon le projet :",[711,5961,5962,5965,5968,5971,5974,5977],{},[714,5963,5964],{},"interrupteur principal et protections amont ;",[714,5966,5967],{},"DDR avec type, courant différentiel assigné, courant assigné et comportement temporel pertinent ;",[714,5969,5970],{},"fusibles ou disjoncteurs avec calibre et courbe nécessaires ;",[714,5972,5973],{},"liaisons et tableaux secondaires utiles à la structure ;",[714,5975,5976],{},"appareils de réserve comme réserve, sans canalisation fictive ;",[714,5978,5979],{},"identification unique de chaque tableau et départ.",[17,5981,5982],{},"La série 300 mA puis 30 mA ne démontre pas la sélectivité. Forme d'onde, immunité renforcée et temporisation sont distinctes. Coordination des références, court-circuit et temps de coupure restent à calculer.",[12,5984,5986],{"id":5985},"_4-référencer-chaque-circuit-terminal","4. Référencer chaque circuit terminal",[17,5988,5989],{},"Chaque circuit élémentaire reçoit une lettre majuscule. Points lumineux, prises et commandes sont numérotés depuis la protection amont. La même référence apparaît sur l'étiquette du tableau et au plan de position.",[17,5991,5992],{},"Pour chaque départ, identifiez : usage, charges, circuit éclairage\u002Fprises\u002Fmixte\u002Fdédié, appareils fixes, boîtes intermédiaires, DDR associé et concordance avec les deux plans. “Cuisine” ne distingue pas éclairage, prises de travail, lave-vaisselle et plaque lorsque ces fonctions utilisent plusieurs circuits.",[12,5994,5996],{"id":5995},"_5-compléter-les-canalisations","5. Compléter les canalisations",[17,5998,5999],{},"La sous-section 3.1.2.2 exige nature, section, nombre de conducteurs et mode de pose. Ces données se rattachent au segment concerné. Après une dérivation, canalisation ou pose peuvent changer ; une seule mention au départ ne doit pas masquer la différence.",[17,6001,6002],{},"Le dimensionnement complet examine aussi courant d'emploi, calibre et capacité admissible, pose et groupement, température, longueur et chute de tension, court-circuit et boucle de défaut, sections minimales et conducteur de protection. Le tableau 4.11 donne des plafonds domestiques pour le cuivre, pas un calcul universel.",[17,6004,6005,6006,6009],{},"Une étiquette ",[4068,6007,6008],{},"XVB 3G2,5"," ne sert que si elle correspond au matériel posé. Confirmez avec ce qui reste visible et les documents d'exécution.",[12,6011,6013],{"id":6012},"_6-ajouter-points-boîtes-et-commandes","6. Ajouter points, boîtes et commandes",[17,6015,6016],{},"L'unifilaire reprend prises, éclairages, interrupteurs, boîtes de connexion\u002Fdérivation et appareils fixes. Utilisez le tableau 2.23. Si aucun signe ne convient, définissez un symbole univoque dans la légende.",[17,6018,6019],{},"Différenciez lorsque nécessaire : prise simple\u002Fmultiple, avec terre, commandée ou données ; point lumineux et commande ; poussoir, relais, détecteur ou domotique ; appareil raccordé à demeure ou charge de prise ; boîte de connexion ou de dérivation. Un rectangle général bien libellé vaut mieux qu'une icône décorative non définie.",[12,6021,6023],{"id":6022},"_7-ne-pas-oublier-les-sources","7. Ne pas oublier les sources",[17,6025,6026],{},"PV, onduleur, batterie, générateur ou transformateur appartiennent à la structure. Leurs caractéristiques figurent sur l'unifilaire ou dans le dossier. Pour une installation photovoltaïque domestique basse tension, la section 9.1.2 ajoute instructions d'exploitation et entretien, consignes de sécurité et références techniques du matériel installé.",[17,6028,6029],{},"Un symbole de panneau près du tableau ne décrit pas point de raccordement, protections et convertisseurs. Établissez quelles sources peuvent fournir, où elles se connectent et par quels appareils. Ne supposez pas qu'une batterie exporte. Les installations de sécurité ou critiques peuvent nécessiter plans et listes supplémentaires.",[12,6031,6033],{"id":6032},"_8-synchroniser-le-plan-de-position","8. Synchroniser le plan de position",[17,6035,6036],{},"Placez chaque tableau, boîte, prise, lumière, commande, appareil fixe et source avec la même référence. Faites le contrôle dans les deux sens :",[5034,6038,6039,6042,6045,6048,6051],{},[714,6040,6041],{},"retrouver chaque élément unifilaire sur le plan ;",[714,6043,6044],{},"retrouver chaque symbole spatial sur l'unifilaire ;",[714,6046,6047],{},"comparer lettre et numéro ;",[714,6049,6050],{},"confirmer niveau, local et tableau ;",[714,6052,6053],{},"inclure boîtes cachées et éléments extérieurs.",[17,6055,6056],{},"N'inventez pas un trajet de câble invisible. Le plan localise les éléments requis ; un plan de câbles ou de prises de terre supplémentaire ne se crée qu'avec des informations sûres.",[12,6058,6060],{"id":6059},"_9-figer-létat-réel-avant-le-contrôle","9. Figer l'état réel avant le contrôle",[17,6062,6063],{},"La nouvelle installation subit le contrôle de conformité avant mise en usage. L'organisme compare exécution et plans et vérifie notamment terre, isolement, continuité et coordination des protections.",[17,6065,6066],{},"Avant le rendez-vous, confrontez chantier et dossier : référence ou calibre réellement posé, changement de câble, prise\u002Flumière\u002Fboîte ajoutée, circuit déplacé sous un autre DDR, étiquettes et versions. Corrigez installation et documents ensemble. On ne résout pas un défaut technique en modifiant seulement le dessin.",[12,6068,6070],{"id":6069},"_10-organiser-dossier-et-évolutions","10. Organiser dossier et évolutions",[17,6072,6073],{},"Le dossier domestique contient les deux plans, rapports et, selon le cas, preuves et documents de modification. Le propriétaire le conserve en deux exemplaires et le transmet au nouveau propriétaire.",[17,6075,6076],{},"Après contrôle, une modification importante demande des plans actualisés. Les modifications non importantes suivent leur règle de description et le plan de position reste à jour. Conservez séparément version visée et révisions ultérieures.",[12,6078,6080],{"id":6079},"vérification-finale","Vérification finale",[711,6082,6085,6094,6100,6106,6112,6118,6124,6130,6136,6142,6148],{"className":6083},[6084],"contains-task-list",[714,6086,6089,6093],{"className":6087},[6088],"task-list-item",[6090,6091],"input",{"disabled":1234,"type":6092},"checkbox"," identité, version, adresse et responsable complets",[714,6095,6097,6099],{"className":6096},[6088],[6090,6098],{"disabled":1234,"type":6092}," tension, courant et raccordement réels",[714,6101,6103,6105],{"className":6102},[6088],[6090,6104],{"disabled":1234,"type":6092}," tous les tableaux, protections et sources représentés",[714,6107,6109,6111],{"className":6108},[6088],[6090,6110],{"disabled":1234,"type":6092}," chaque circuit terminal identifié",[714,6113,6115,6117],{"className":6114},[6088],[6090,6116],{"disabled":1234,"type":6092}," canalisation, section, conducteurs et pose indiqués",[714,6119,6121,6123],{"className":6120},[6088],[6090,6122],{"disabled":1234,"type":6092}," prises, lumières, boîtes, commandes et appareils fixes présents",[714,6125,6127,6129],{"className":6126},[6088],[6090,6128],{"disabled":1234,"type":6092}," symboles officiels ou légende sans ambiguïté",[714,6131,6133,6135],{"className":6132},[6088],[6090,6134],{"disabled":1234,"type":6092}," références identiques au tableau et au plan de position",[714,6137,6139,6141],{"className":6138},[6088],[6090,6140],{"disabled":1234,"type":6092}," modifications de chantier intégrées",[714,6143,6145,6147],{"className":6144},[6088],[6090,6146],{"disabled":1234,"type":6092}," dossier PV et systèmes particuliers complété",[714,6149,6151,6153],{"className":6150},[6088],[6090,6152],{"disabled":1234,"type":6092}," calculs et mesures réalisés hors du dessin",[12,6155,6157],{"id":6156},"réconcilier-étude-chantier-et-mise-en-service","Réconcilier étude, chantier et mise en service",[17,6159,6160],{},"Un projet neuf évolue presque toujours entre offre et mise sous tension. Tenez une liste d'écarts avec repère prévu, réalisation effective, décision responsable, documents touchés et preuve encore manquante. Un tableau déplacé, une prise extérieure ajoutée, la puissance d'une pompe à chaleur modifiée ou un onduleur PV ajouté tardivement sont des cas typiques. Le schéma d'étude ne devient as-built que lorsque chaque ligne est résolue ou explicitement déclarée non exécutée.",[17,6162,6163],{},"Parcourez ensuite l'installation avec les étiquettes et les relevés de mise en service. Ne commandez pas les circuits en vous fiant seulement aux noms supposés des locaux. Comparez l'étiquette physique du tableau, le repère de l'unifilaire et le point du plan de position. Si conducteurs, protections ou réglages changent pendant la mise en service, corrigez les documents après intervention. Un PDF exporté tôt n'est pas une version finale parce que sa mise en page paraît achevée.",[12,6165,6167],{"id":6166},"exemple-de-revue-dun-circuit-terminal-neuf","Exemple de revue d'un circuit terminal neuf",[17,6169,6170],{},"Pour un sèche-linge raccordé à demeure, « buanderie » ne suffit pas. Le dossier montre tableau d'origine et chaîne de protection, repère stable du circuit, canalisation avec nombre et section des conducteurs, puis appareil fixe terminal. Le même code est inscrit à l'emplacement réel sur le plan de position. Notice du fabricant, caractéristiques et réglages requis restent conservés séparément comme documentation technique.",[17,6172,6173],{},"Contrôlez ensuite les interfaces. Le chemin du conducteur de protection est-il traçable ? Le mode de raccordement réel correspond-il au dessin ? Une alimentation individuelle prévue est-elle devenue commune sur chantier ? Une boîte de dérivation manque-t-elle sur l'unifilaire ? Ces questions évitent qu'un jeu formellement complet ne conserve un état d'étude dépassé.",[12,6175,6177],{"id":6176},"remettre-une-série-documentaire-maîtrisée","Remettre une série documentaire maîtrisée",[17,6179,6180],{},"Identifiez l'édition finale par projet, adresse, indice et date d'export. Regroupez unifilaire, plan de position, rapport de contrôle et documents techniques utiles dans un dossier ordonné. Séparez clairement copies de travail et versions remplacées. Le propriétaire doit savoir quels fichiers sont actuels et que chaque transformation ultérieure impose une nouvelle mise à jour.",[17,6182,1759,6183,6188],{},[203,6184,6187],{"href":6185,"rel":6186},"https:\u002F\u002Feconomie.fgov.be\u002Ffr\u002Fthemes\u002Fenergie\u002Fsources-et-vecteurs-denergie\u002Felectricite\u002Fsecurite-et-controle-des\u002Fcontrole-des-installations",[5373],"page officielle du SPF Économie sur le contrôle domestique"," énumère les plans à fournir au minimum et résume leur contenu. Elle ne remplace ni les prescriptions détaillées du RGIE Livre 1 V06 ni l'appréciation compétente du projet concret.",[12,6190,6192],{"id":6191},"préparer-avec-planelec","Préparer avec PlanElec",[17,6194,6195],{},"PlanElec peut regrouper fond de plan, topologie et données des tableaux, exporter les deux plans en PDF et exécuter un auto-contrôle indicatif des règles prises en charge. Il ne remplace ni vérification du raccordement, ni calcul de câble, ni relevé de chantier ou mesure. Un contrôle logiciel sans erreur n'est pas une déclaration de conformité ; l'organisme agréé réalise le contrôle officiel.",[12,6197,6199],{"id":6198},"guides-liés","Guides liés",[711,6201,6202,6207,6212],{},[714,6203,6204],{},[203,6205,6206],{"href":4091},"Coordonner unifilaire et plan de position",[714,6208,6209],{},[203,6210,6211],{"href":4952},"Comprendre les symboles RGIE",[714,6213,6214],{},[203,6215,6217],{"href":6216},"\u002Ffr\u002Fblog\u002Fcontrole-electrique","Préparer le contrôle électrique",[17,6219,6220],{},[203,6221,6222],{"href":1204},"Démarrer un projet neuf dans PlanElec →",[17,6224,6225],{},[60,6226,6227],{},"Référence : RGIE Livre 1 V06, notamment chapitre 2.13, section 3.1.2, chapitre 6.4 et section 9.1.2. Le texte officiel et l'installation exécutée restent déterminants.",{"title":1212,"searchDepth":1213,"depth":1213,"links":6229},[6230,6231,6232,6233,6234,6235,6236,6237,6238,6239,6240,6241,6242,6243,6244,6245,6246],{"id":5882,"depth":1213,"text":5883},{"id":5892,"depth":1213,"text":5893},{"id":5922,"depth":1213,"text":5923},{"id":5955,"depth":1213,"text":5956},{"id":5985,"depth":1213,"text":5986},{"id":5995,"depth":1213,"text":5996},{"id":6012,"depth":1213,"text":6013},{"id":6022,"depth":1213,"text":6023},{"id":6032,"depth":1213,"text":6033},{"id":6059,"depth":1213,"text":6060},{"id":6069,"depth":1213,"text":6070},{"id":6079,"depth":1213,"text":6080},{"id":6156,"depth":1213,"text":6157},{"id":6166,"depth":1213,"text":6167},{"id":6176,"depth":1213,"text":6177},{"id":6191,"depth":1213,"text":6192},{"id":6198,"depth":1213,"text":6199},"Du raccordement aux protections, canalisations, références et plan de position : checklist complète d’un projet domestique neuf selon le RGIE Livre 1 V06.",{},"\u002Fblog\u002Fnew-build-single-line-checklist.fr",{"title":5876,"description":6247},"schema-unifilaire-construction-neuve-checklist","blog\u002Fnew-build-single-line-checklist.fr",[1243,1242,6254,1248,6255,2003,6256,1249],"construction neuve","checklist","contrôle de conformité","RmEHvd7IooT1ovGWXUMeyvEXFLFopu17OAL8Zmsbwo0",{"id":6259,"title":6260,"articleId":6261,"body":6262,"category":5859,"date":5432,"description":6612,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":6613,"navigation":1234,"path":6614,"publishDate":5432,"readTime":4995,"refreshInterval":1237,"seo":6615,"slug":6616,"stem":6617,"tags":6618,"__hash__":6623},"blog\u002Fblog\u002Fpv-ev-charger-single-line-diagram.fr.md","Combiner photovoltaïque et borne de recharge sur le schéma unifilaire","pv-ev-charger-single-line-diagram",{"type":9,"value":6263,"toc":6596},[6264,6271,6274,6278,6281,6301,6304,6308,6311,6317,6320,6324,6327,6350,6357,6361,6364,6367,6390,6397,6401,6404,6421,6424,6428,6431,6437,6440,6457,6460,6464,6467,6470,6474,6477,6480,6500,6504,6507,6510,6514,6517,6520,6523,6527,6530,6533,6550,6553,6557,6560,6563,6567,6572,6576,6593],[17,6265,6266,6267,6270],{},"Une application énergétique peut montrer le soleil qui charge directement la voiture. Sur le schéma électrique, l’installation photovoltaïque et la borne constituent généralement ",[221,6268,6269],{},"deux branches distinctes"," du même réseau de distribution interne. L’onduleur injecte côté AC ; une borne classique consomme via son circuit terminal séparé. Un gestionnaire d’énergie mesure et pilote les deux, sans les transformer en série électrique.",[17,6272,6273],{},"Le schéma commun doit montrer les sources, les directions possibles, les limites de protection et les points de mesure. Il ne doit pas promettre un niveau d’autoconsommation, une puissance disponible ou une acceptation du gestionnaire de réseau qui dépend du projet réel.",[12,6275,6277],{"id":6276},"inventorier-trois-sous-ensembles","Inventorier trois sous-ensembles",[17,6279,6280],{},"Séparez d’abord :",[5034,6282,6283,6289,6295],{},[714,6284,6285,6288],{},[221,6286,6287],{},"Réseau et distribution principale :"," raccordement, compteur, protection générale, terre et tableaux concernés.",[714,6290,6291,6294],{},[221,6292,6293],{},"Production PV :"," modules ou chaînes, partie DC, onduleur, protection AC et point d’injection.",[714,6296,6297,6300],{},[221,6298,6299],{},"Recharge :"," circuit séparé, protections contre surintensités et courants de défaut, câble, point de connexion et éventuelle gestion de charge.",[17,6302,6303],{},"Un appareil hybride ou une borne bidirectionnelle peut imposer une autre architecture. Ne la représentez que d’après le concept autorisé du fabricant, avec les références de modèle et de version conservées au dossier.",[12,6305,6307],{"id":6306},"architecture-ac-courante","Architecture AC courante",[17,6309,6310],{},"Une installation conventionnelle peut se lire ainsi :",[5508,6312,6315],{"className":6313,"code":6314,"language":5513,"meta":1212},[5511],"Réseau ↔ compteur ↔ tableau principal\n                    ├─ branche PV AC ↔ protection ↔ onduleur ↔ partie PV DC\n                    └─ branche recharge → protection → câble → borne → véhicule\n                                        └─ mesure\u002Fgestion de charge, si présente\n",[4068,6316,6314],{"__ignoreMap":1212},[17,6318,6319],{},"La double flèche indique une direction énergétique possible, pas une fonction de protection. Une borne unidirectionnelle demeure un récepteur même si son logiciel propose la « recharge au surplus solaire ».",[12,6321,6323],{"id":6322},"détailler-la-branche-photovoltaïque","Détailler la branche photovoltaïque",[17,6325,6326],{},"Le chapitre 7.112 du RGIE Livre 1 V06 ajoute des prescriptions pour les installations photovoltaïques domestiques à basse tension jusqu’à 10 kVA. Le schéma et le dossier doivent permettre d’identifier :",[711,6328,6329,6332,6335,6338,6341,6344,6347],{},[714,6330,6331],{},"générateur PV et organisation utile des chaînes ou modules ;",[714,6333,6334],{},"canalisations DC, polarité et section ;",[714,6336,6337],{},"sectionnement et protections DC installés ou intégrés ;",[714,6339,6340],{},"modèle exact d’onduleur et puissance AC maximale ;",[714,6342,6343],{},"canalisation AC, protection contre les surintensités, différentiel et autres dispositifs conçus ;",[714,6345,6346],{},"point de raccordement précis au tableau ;",[714,6348,6349],{},"avertissements et identifications de l’installation réalisée.",[17,6351,5604,6352,6356],{},[203,6353,6355],{"href":6354},"\u002Ffr\u002Fblog\u002Fpanneaux-solaires-schema","panneaux photovoltaïques sur le schéma"," développe cette branche. Une case générique « protection PV » ne décrit pas les fonctions réellement présentes.",[12,6358,6360],{"id":6359},"conserver-un-circuit-distinct-pour-la-borne","Conserver un circuit distinct pour la borne",[17,6362,6363],{},"Le chapitre 7.22 prévoit un circuit séparé pour chaque point de connexion d’une installation de recharge conductive fixe. Chaque circuit AC séparé est protégé individuellement par un différentiel de maximum 30 mA. La protection doit rester efficace en présence de composantes continues perturbatrices, soit par un différentiel approprié, soit par sa coordination avec une détection de courant de défaut continu. Une protection contre les surintensités est également prévue pour chaque circuit.",[17,6365,6366],{},"Indiquez donc :",[711,6368,6369,6372,6375,6378,6381,6384,6387],{},[714,6370,6371],{},"repère du circuit et phases utilisées ;",[714,6373,6374],{},"protection contre les surintensités, nombre de pôles et courant assigné ;",[714,6376,6377],{},"type de différentiel et éventuelle détection DC coordonnée ;",[714,6379,6380],{},"type de câble, nombre de conducteurs et section ;",[714,6382,6383],{},"borne et nombre de points de connexion ;",[714,6385,6386],{},"puissance nominale ou courant maximal de recharge ;",[714,6388,6389],{},"équipements fixes de commande, mesure ou coupure.",[17,6391,6392,6393,6396],{},"La combinaison acceptable dépend du RGIE, des normes produit et de la notice exacte. Le guide ",[203,6394,6395],{"href":5607},"type A ou type B"," fournit le contexte mais ne valide pas un modèle particulier.",[12,6398,6400],{"id":6399},"montrer-la-gestion-dénergie-à-sa-juste-place","Montrer la gestion d’énergie à sa juste place",[17,6402,6403],{},"La recharge au surplus PV ou la limitation du prélèvement nécessite une mesure et une régulation. Le système peut comporter compteur d’énergie, transformateurs de courant, contrôleur, communication et borne pilotable. Placez les éléments électriques fixes là où ils sont réellement raccordés :",[711,6405,6406,6409,6412,6415,6418],{},[714,6407,6408],{},"point de mesure au raccordement ou au tableau concerné ;",[714,6410,6411],{},"capteurs de courant avec phases et sens corrects ;",[714,6413,6414],{},"alimentation du contrôleur ;",[714,6416,6417],{},"contacteur ou contact de commande s’il réalise une coupure ou autorisation électrique ;",[714,6419,6420],{},"liaison de données uniquement dans la mesure utile à la compréhension.",[17,6422,6423],{},"Une ligne pointillée peut distinguer la communication des conducteurs de puissance si la légende l’explique. Évitez « 100 % solaire » : production, consommation du bâtiment, demande du véhicule et stratégie varient.",[12,6425,6427],{"id":6426},"phases-et-bilan-de-puissance","Phases et bilan de puissance",[17,6429,6430],{},"Représentez l’affectation réelle des phases. Un onduleur monophasé et une borne triphasée ne deviennent pas une même branche parce qu’un compteur effectue un bilan. Une limite configurée dans le logiciel ne remplace ni le dimensionnement des conducteurs ni la protection contre les surintensités.",[17,6432,1759,6433,6436],{},[203,6434,6435],{"href":1579},"coordination entre section et disjoncteur"," reste donc à établir complètement et séparément pour les branches PV et recharge.",[17,6438,6439],{},"L’étude vérifie notamment :",[711,6441,6442,6445,6448,6451,6454],{},[714,6443,6444],{},"puissance de raccordement et charges admissibles par phase ;",[714,6446,6447],{},"production et consommation simultanées ;",[714,6449,6450],{},"courant dans les jeux de barres et appareils amont selon les directions possibles ;",[714,6452,6453],{},"court-circuit, sélectivité et chute de tension ;",[714,6455,6456],{},"plages de mesure et limites constructeur de la régulation.",[17,6458,6459],{},"Le schéma consigne le résultat retenu, pas l’ensemble du calcul.",[12,6461,6463],{"id":6462},"identifier-clairement-la-recharge-bidirectionnelle","Identifier clairement la recharge bidirectionnelle",[17,6465,6466],{},"Si la borne peut renvoyer l’énergie du véhicule vers l’installation ou le réseau, elle n’est plus seulement réceptrice. Le point 7.22.5.4 renvoie alors aux règles des unités de production décentralisée et prévoit des avertissements aux bornes et tableaux concernés. Synergrid précise qu’une infrastructure bidirectionnelle, ou techniquement capable de l’être, relève de C10\u002F11 et de l’homologation C10\u002F26 ; une borne strictement unidirectionnelle n’en relève pas.",[17,6468,6469],{},"Représentez directions, sectionnement et protections selon le concept approuvé. Un schéma de wallbox classique ne doit pas être réutilisé pour Vehicle-to-Home ou Vehicle-to-Grid.",[12,6471,6473],{"id":6472},"plan-de-situation-et-dossier","Plan de situation et dossier",[17,6475,6476],{},"Localisez modules, onduleur, sectionneurs pertinents, tableaux, mesure fixe, borne et place de stationnement associée. Répétez les repères de circuits de l’unifilaire. Conservez fiches techniques, déclarations, paramètres et modifications dans le dossier de l’installation.",[17,6478,6479],{},"La revue finale vérifie :",[711,6481,6482,6485,6488,6491,6494,6497],{},[714,6483,6484],{},"concordance du schéma, des étiquettes et de l’as-built ;",[714,6486,6487],{},"continuité lisible des deux branches jusqu’au point commun ;",[714,6489,6490],{},"directions d’énergie correctes ;",[714,6492,6493],{},"protections placées du bon côté sans doublons fictifs ;",[714,6495,6496],{},"gestion de charge représentée comme commande, jamais comme substitut à une protection ;",[714,6498,6499],{},"fonction uni- ou bidirectionnelle clairement identifiée.",[12,6501,6503],{"id":6502},"répercuter-les-évolutions-ultérieures","Répercuter les évolutions ultérieures",[17,6505,6506],{},"Ces systèmes évoluent souvent après la réception : nouvel onduleur, modules supplémentaires, second point de recharge, batterie ou nouvelle mesure. Ne changez pas seulement le nom d’un appareil ; retracez chaque branche jusqu’au tableau commun.",[17,6508,6509],{},"Consignez la source ou le point ajouté, la nouvelle valeur AC et les directions possibles, les protections révisées, la position et les phases des capteurs, les canalisations et les étiquettes. Une limite logicielle reste liée à une version d’appareil et à des paramètres conservés. Une batterie ou un véhicule bidirectionnel n’est pas une fonction invisible de l’application : source, sectionnement, protection et avertissements doivent rester traçables. Archivez l’ancien plan et identifiez clairement la révision en vigueur.",[12,6511,6513],{"id":6512},"exemple-ajouter-un-second-point-de-recharge-à-une-installation-pv","Exemple : ajouter un second point de recharge à une installation PV",[17,6515,6516],{},"Un bâtiment possède déjà un onduleur PV et une borne unidirectionnelle ; un second point de connexion est ajouté. Ne copiez pas simplement le premier symbole. Déterminez s'il s'agit d'un autre appareil, d'une station à deux points ou d'une architecture différente, puis localisez les protections contre les surintensités et les courants différentiels réellement présentes. Le chapitre 7.22 prévoit une possibilité étroite de protection commune contre les surintensités pour plusieurs points non utilisés simultanément si chaque point reste correctement protégé. Ce n'est pas une autorisation générale de partager circuits ou DDR.",[17,6518,6519],{},"Mettez ensuite à jour puissance de raccordement, affectation des phases et gestion de charge. Les points peuvent partager dynamiquement une limite, mais le dessin doit encore identifier chacun, sa subdivision électrique réelle et la charge maximale autorisée. Les capteurs de courant correspondent aux bons conducteurs et au bon sens. Une interface logicielle montrant deux places ne prouve ni le câblage as-built ni les protections intégrées.",[17,6521,6522],{},"Réexaminez aussi la branche PV. Si seule la consommation évolue, modules et onduleur restent peut-être identiques, mais le tableau commun et les directions de courant peuvent demander une nouvelle étude. L'ajout simultané d'un onduleur hybride ou d'une batterie introduit une autre source ou un autre mode, avec logique de protection, sectionnement et documentation propre.",[12,6524,6526],{"id":6525},"constituer-les-preuves-de-mise-en-service","Constituer les preuves de mise en service",[17,6528,6529],{},"Associez chaque frontière importante du schéma à une preuve : plaque ou fiche pour les puissances, architecture fabricant pour les protections intégrées, relevés d'essai pour l'installation exécutée et export de configuration pour les limites pertinentes. Marquez les hypothèses comme ouvertes. N'indiquez un type de DDR ou une détection DC comme installé qu'après vérification de l'appareil et de son montage.",[17,6531,6532],{},"Lors de la revue finale, parcourez plusieurs états d'énergie :",[5034,6534,6535,6538,6541,6544,6547],{},[714,6536,6537],{},"recharge nocturne sans production PV ;",[714,6539,6540],{},"production PV avec faible consommation du bâtiment ;",[714,6542,6543],{},"PV et véhicule face à une limite dynamique d'importation ;",[714,6545,6546],{},"perte de mesure ou de communication du gestionnaire de charge ;",[714,6548,6549],{},"pour un appareil bidirectionnel, retour d'énergie du véhicule.",[17,6551,6552],{},"Pour chaque état, chemin, limite, protection et comportement de repli doivent s'expliquer par la conception et le système fabricant. L'unifilaire ne reproduit pas chaque décision logicielle, mais ne cache ni composant électrique pertinent ni direction possible d'une source.",[12,6554,6556],{"id":6555},"distinguer-homologation-produit-et-procédure-réseau","Distinguer homologation produit et procédure réseau",[17,6558,6559],{},"Documentation RGIE, homologation Synergrid et procédure du gestionnaire de réseau répondent à des questions différentes. Une protection correctement étudiée ne prouve pas l'inscription C10\u002F26 ; un produit homologué ne prouve pas son installation correcte dans ce bâtiment. Synergrid précise actuellement qu'une borne strictement unidirectionnelle ne requiert pas l'homologation C10\u002F26 au titre de C10\u002F11 éd.2.4 ; d'autres conditions techniques ou réseau peuvent subsister.",[17,6561,6562],{},"Conservez modèle, firmware, capacité uni- ou bidirectionnelle, échanges avec le gestionnaire et réglages réels avec l'indice du plan. Le dossier montre ainsi l'état technique auquel contrôle ou autorisation se rapportait.",[12,6564,6566],{"id":6565},"réaliser-les-documents-dans-planelec","Réaliser les documents dans PlanElec",[17,6568,5819,6569,6571],{},[203,6570,5823],{"href":5822},", vous pouvez saisir les branches PV et recharge, les rapprocher du plan de situation et exporter les deux documents en PDF. L’auto-contrôle indicatif peut signaler certaines données prises en charge. Il ne calcule pas toute la coordination des protections, ne donne pas l’accord du gestionnaire de réseau, ne certifie pas la conformité RGIE et ne produit pas de rapport officiel.",[12,6573,6575],{"id":6574},"sources-officielles","Sources officielles",[711,6577,6578,6585],{},[714,6579,6580,6584],{},[203,6581,6583],{"href":5371,"rel":6582},[5373],"RGIE Livre 1 publié par le SPF Économie"," : chapitres 7.22 et 7.112, parties 3 et 9, version V06 examinée.",[714,6586,6587,6592],{},[203,6588,6591],{"href":6589,"rel":6590},"https:\u002F\u002Fwww.synergrid.be\u002Ffr\u002Fhomologation\u002Felectricite\u002Funites-de-production-decentralisee",[5373],"Synergrid : homologation des unités de production décentralisée"," : C10\u002F11 éd.2.4, C10\u002F26 et distinction de la recharge bidirectionnelle.",[17,6594,6595],{},"Revue de fond au 29 août 2026. Les conditions de raccordement et versions constructeur doivent être revérifiées avant exécution.",{"title":1212,"searchDepth":1213,"depth":1213,"links":6597},[6598,6599,6600,6601,6602,6603,6604,6605,6606,6607,6608,6609,6610,6611],{"id":6276,"depth":1213,"text":6277},{"id":6306,"depth":1213,"text":6307},{"id":6322,"depth":1213,"text":6323},{"id":6359,"depth":1213,"text":6360},{"id":6399,"depth":1213,"text":6400},{"id":6426,"depth":1213,"text":6427},{"id":6462,"depth":1213,"text":6463},{"id":6472,"depth":1213,"text":6473},{"id":6502,"depth":1213,"text":6503},{"id":6512,"depth":1213,"text":6513},{"id":6525,"depth":1213,"text":6526},{"id":6555,"depth":1213,"text":6556},{"id":6565,"depth":1213,"text":6566},{"id":6574,"depth":1213,"text":6575},"Représentez onduleur PV, borne, circuits distincts, protections, mesure d’énergie et retour possible dans un schéma unifilaire commun.",{},"\u002Fblog\u002Fpv-ev-charger-single-line-diagram.fr",{"title":6260,"description":6612},"photovoltaique-borne-recharge-schema-unifilaire","blog\u002Fpv-ev-charger-single-line-diagram.fr",[6619,6620,5869,1242,6621,6622,1249],"Photovoltaïque","Borne de recharge","Gestion de puissance","Réinjection","eZp3p5rDSsmfRJ2xQUD6MEBgFp7TlGlJ6T1lQX2QL8A",{"id":6625,"title":6626,"articleId":6627,"body":6628,"category":5859,"date":5432,"description":6988,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":6989,"navigation":1234,"path":6990,"publishDate":5432,"readTime":5863,"refreshInterval":1237,"seo":6991,"slug":6992,"stem":6993,"tags":6994,"__hash__":6999},"blog\u002Fblog\u002Fpv-situation-plan.fr.md","Photovoltaïque sur le plan de situation : modules, onduleur et cheminements","pv-situation-plan",{"type":9,"value":6629,"toc":6966},[6630,6637,6640,6644,6647,6670,6673,6677,6680,6697,6704,6708,6711,6728,6731,6735,6738,6741,6747,6750,6754,6757,6774,6780,6784,6787,6790,6804,6809,6813,6817,6820,6824,6827,6831,6834,6838,6841,6845,6848,6868,6871,6875,6895,6899,6902,6905,6909,6912,6915,6918,6922,6925,6928,6932,6935,6938,6945,6949,6955,6959],[17,6631,6632,6633,6636],{},"Dans un projet photovoltaïque, le schéma unifilaire retient souvent toute l’attention : chaînes, onduleur, protections et raccordement y apparaissent. Le plan de situation répond à une autre question : ",[221,6634,6635],{},"où se trouvent"," les éléments électriques fixes ? Pour une maintenance, une transformation ou un contrôle ultérieur, il faut retrouver les champs de modules, l’onduleur et le parcours jusqu’au tableau.",[17,6638,6639],{},"Ce document n’est ni une étude de stabilité de toiture, ni un second schéma DC complet. Il complète l’unifilaire sans recopier toute sa logique électrique.",[12,6641,6643],{"id":6642},"partir-dun-relevé-as-built","Partir d’un relevé as-built",[17,6645,6646],{},"Utilisez un plan reconnaissable avec niveaux, locaux, accès et zones extérieures importantes. Une vue de toiture ou de façade peut être nécessaire. Relevez sur place :",[711,6648,6649,6652,6655,6658,6661,6664,6667],{},[714,6650,6651],{},"champs de modules et orientation réelle ;",[714,6653,6654],{},"position des onduleurs centraux ou micro-onduleurs ;",[714,6656,6657],{},"sectionnements DC et AC fixes lorsqu’ils existent ;",[714,6659,6660],{},"tableau principal ou secondaire raccordé ;",[714,6662,6663],{},"traversées et cheminements fixes importants ;",[714,6665,6666],{},"armoire de comptage si elle clarifie la liaison ;",[714,6668,6669],{},"batterie, commutation de secours ou autre source intégrée.",[17,6671,6672],{},"Ne reprenez pas le plan d’offre sans contrôle. L’implantation des modules, la place de l’onduleur et le passage des câbles peuvent changer pendant les travaux.",[12,6674,6676],{"id":6675},"représenter-la-zone-de-modules","Représenter la zone de modules",[17,6678,6679],{},"Le champ doit être localisable sans ambiguïté. Selon l’échelle, indiquez :",[711,6681,6682,6685,6688,6691,6694],{},[714,6683,6684],{},"modules individuels ou groupes clairement délimités ;",[714,6686,6687],{},"versant, annexe, façade ou zone au sol concernée ;",[714,6689,6690],{},"repères de chaînes lorsqu’ils assurent la liaison avec l’unifilaire ;",[714,6692,6693],{},"coffrets DC fixes de jonction ou de coupure ;",[714,6695,6696],{},"bords, accès ou compartiments utiles pour comprendre l’emplacement électrique.",[17,6698,6699,6700,6703],{},"Il n’est pas nécessaire de dessiner chaque connecteur sous chaque module. La connexion des chaînes, la polarité, les conducteurs et la protection sont détaillés surtout dans le ",[203,6701,6702],{"href":6354},"schéma unifilaire photovoltaïque",". Les repères de chaîne et d’équipement doivent être identiques.",[12,6705,6707],{"id":6706},"localiser-précisément-londuleur","Localiser précisément l’onduleur",[17,6709,6710],{},"Placez le symbole au lieu réel et distinguez si nécessaire :",[711,6712,6713,6716,6719,6722,6725],{},[714,6714,6715],{},"onduleur central de chaînes ;",[714,6717,6718],{},"plusieurs onduleurs ;",[714,6720,6721],{},"micro-onduleurs près des modules ;",[714,6723,6724],{},"onduleur hybride et batterie séparée ;",[714,6726,6727],{},"dispositifs fixes de coupure associés.",[17,6729,6730],{},"La seule mention « garage » peut être trop vague dans un grand local. Montrez le mur ou la zone technique. Pour un appareil extérieur, identifiez la façade.",[12,6732,6734],{"id":6733},"dessiner-les-cheminements-utiles","Dessiner les cheminements utiles",[17,6736,6737],{},"Le plan doit permettre de suivre spatialement la liaison fixe du champ à l’onduleur, puis au tableau. Montrez les traversées de bâtiment, gaines, colonnes montantes et changements de niveau qui seront cachés après finition.",[17,6739,6740],{},"Différenciez le trajet DC du trajet AC par un type de ligne ou un texte, pas par la couleur seule. Le PDF imprimé en noir et blanc doit rester lisible :",[5508,6742,6745],{"className":6743,"code":6744,"language":5513,"meta":1212},[5511],"PV-DC  ─ ─ ─  cheminement continu depuis les modules\nPV-AC  ─────  cheminement alternatif vers le tableau\nDATA   ·····  liaison fixe de mesure ou communication\n",[4068,6746,6744],{"__ignoreMap":1212},[17,6748,6749],{},"Définissez ces conventions dans la légende. Elles ne précisent pas le type de câble ou le mode de pose, qui restent indiqués sur l’unifilaire.",[12,6751,6753],{"id":6752},"symboles-et-légende-de-projet","Symboles et légende de projet",[17,6755,6756],{},"Le tableau 2.23 du RGIE Livre 1 V06 n’est pas exhaustif. Un signe propre au projet pour le champ PV, l’onduleur ou un sectionneur DC est acceptable s’il est non ambigu et défini dans la légende. Vérifiez :",[711,6758,6759,6762,6765,6768,6771],{},[714,6760,6761],{},"taille suffisante dans le PDF final ;",[714,6763,6764],{},"distinction de forme ou de texte entre onduleur et stockage ;",[714,6766,6767],{},"mêmes références sur toutes les pages ;",[714,6769,6770],{},"information qui ne dépend pas seulement de la couleur ;",[714,6772,6773],{},"séparation claire entre appareil électrique et élément du bâtiment.",[17,6775,6776,6777,6779],{},"La page ",[203,6778,5642],{"href":4952}," explique cette règle de légende.",[12,6781,6783],{"id":6782},"conserver-les-références-communes","Conserver les références communes",[17,6785,6786],{},"La partie 3 du RGIE Livre 1 V06 relie plan de situation et unifilaire par les références de circuits. Le départ AC de l’onduleur porte donc le même repère sur les deux documents. Les références de chaînes ou d’appareils utilisées des deux côtés restent elles aussi identiques.",[17,6788,6789],{},"Effectuez un contrôle croisé :",[5034,6791,6792,6795,6798,6801],{},[714,6793,6794],{},"Chaque élément PV fixe du plan de situation existe sur l’unifilaire ou dans sa légende.",[714,6796,6797],{},"Chaque élément spatialement pertinent de l’unifilaire possède une position retrouvable.",[714,6799,6800],{},"Les noms de tableaux et de niveaux concordent.",[714,6802,6803],{},"Adresse, date et indice de version sont identiques.",[17,6805,5604,6806,6808],{},[203,6807,5681],{"href":4091}," détaille leur complémentarité.",[12,6810,6812],{"id":6811},"configurations-particulières","Configurations particulières",[5686,6814,6816],{"id":6815},"micro-onduleurs","Micro-onduleurs",[17,6818,6819],{},"Pour de nombreux appareils identiques, un groupe avec quantité, type et modules associés peut être plus lisible que des symboles superposés. Le parallélisme électrique reste décrit sur l’unifilaire.",[5686,6821,6823],{"id":6822},"batterie-domestique","Batterie domestique",[17,6825,6826],{},"Localisez batterie, onduleur, coupures fixes et éventuel tableau de secours. La batterie reçoit son propre symbole. Les contraintes d’implantation proviennent de l’étude et du constructeur ; le plan consigne la position exécutée.",[5686,6828,6830],{"id":6829},"annexe-ou-installation-au-sol","Annexe ou installation au sol",[17,6832,6833],{},"Montrez le trajet entre bâtiments, le point d’entrée et les tableaux secondaires. Une flèche « vers maison » sans destination précise n’aide pas une intervention future.",[5686,6835,6837],{"id":6836},"installation-existante","Installation existante",[17,6839,6840],{},"La partie 8 prévoit, pour certaines installations photovoltaïques domestiques existantes jusqu’à 10 kVA, une dérogation limitée permettant une description écrite éventuellement accompagnée de photos. Cette règle de l’existant ne doit pas être généralisée à une construction neuve ou à une modification importante. Faites qualifier le cas concret.",[12,6842,6844],{"id":6843},"dossier-et-photographies","Dossier et photographies",[17,6846,6847],{},"Les photos complètent utilement le plan pour les parcours cachés, la toiture et les plaques signalétiques, mais ne remplacent pas automatiquement les plans structurés. Conservez :",[711,6849,6850,6853,6856,6859,6862,6865],{},[714,6851,6852],{},"plan de situation et unifilaire finaux ;",[714,6854,6855],{},"données des modules et onduleurs ;",[714,6857,6858],{},"informations de chaînes et mesures disponibles ;",[714,6860,6861],{},"notices et déclarations des équipements ;",[714,6863,6864],{},"rapports de l’organisme agréé ;",[714,6866,6867],{},"modifications ultérieures avec nouvel indice.",[17,6869,6870],{},"Le propriétaire garde le dossier disponible et le fait mettre à jour lors des transformations.",[12,6872,6874],{"id":6873},"contrôle-avant-export","Contrôle avant export",[711,6876,6877,6880,6883,6886,6889,6892],{},[714,6878,6879],{},"Les champs, onduleurs et appareils fixes sont-ils à leur position réelle ?",[714,6881,6882],{},"Les trajets DC et AC sont-ils distingués et légendés ?",[714,6884,6885],{},"Les repères de circuits, chaînes et tableaux concordent-ils avec l’unifilaire ?",[714,6887,6888],{},"Symboles et textes restent-ils lisibles au format d’impression ?",[714,6890,6891],{},"Le document correspond-il à l’as-built plutôt qu’à l’offre initiale ?",[714,6893,6894],{},"Adresse, date et version sont-elles identiques sur les deux plans ?",[12,6896,6898],{"id":6897},"organiser-un-plan-sur-plusieurs-feuilles","Organiser un plan sur plusieurs feuilles",[17,6900,6901],{},"Si toiture, local technique et tableaux ne tiennent pas lisiblement sur une page, créez des vues nommées. Une feuille générale relie bâtiment, versants et tableaux ; des détails agrandissent les champs et zones techniques. Numérotez les feuilles et utilisez des renvois explicites, par exemple « PV-DC suite feuille S2 ».",[17,6903,6904],{},"Chaque extrait conserve des repères d’orientation : niveau, local, nord ou façade reconnaissable. Ne répétez pas un identifiant à plusieurs endroits sauf s’il existe réellement plusieurs appareils. Un tableau de références peut relier symbole, ID, circuit et feuille. Le dossier reste ainsi exploitable sans miniaturiser les textes ni tracer des lignes ambiguës sur toute la page.",[12,6906,6908],{"id":6907},"exemple-deux-versants-et-un-onduleur-dans-le-local-technique","Exemple : deux versants et un onduleur dans le local technique",[17,6910,6911],{},"Prenons une maison avec modules sur versants est et ouest, deux chaînes DC et un onduleur dans le local technique. Représentez deux champs identifiés plutôt qu'une icône au milieu du toit. Indiquez quelle référence de chaîne appartient à chaque versant et où ses câbles DC entrent dans le bâtiment. Ne dessinez un trajet commun vers le local que si les canalisations posées suivent réellement ce chemin.",[17,6913,6914],{},"Attribuez à l'onduleur un repère stable et sa position réelle sur le mur. Si sectionnement DC, protection contre les surtensions ou autre matériel fixe est externe, localisez-le aussi et reliez son identifiant à l'unifilaire. Laissez les fonctions intégrées au dossier de l'appareil au lieu d'inventer des boîtiers. Le trajet AC aboutit au bon tableau et au bon circuit ; une ligne dirigée vers le local le plus proche ne donne aucune traçabilité.",[17,6916,6917],{},"Vérifiez l'orientation du détail de toiture. Versant, corniche, faîte, nord et contours reconnaissables doivent permettre de retrouver champ et pénétration sur place. Le plan de position n'est pas un plan mécanique et ne montre pas chaque crochet. Il représente toutefois les différences utiles à l'affectation électrique, au travail sûr et au diagnostic ultérieur.",[12,6919,6921],{"id":6920},"relever-honnêtement-les-chemins-cachés-ou-inaccessibles","Relever honnêtement les chemins cachés ou inaccessibles",[17,6923,6924],{},"N'inventez pas un tracé géométriquement exact lorsqu'une installation existante le masque. Signalez un tronçon caché ou repris d'une documentation conservée et gardez la source de l'information. Des photos des entrées, étiquettes, traversées et du local réduisent l'incertitude. Un trait interrompu n'a ce sens que si la légende le définit.",[17,6926,6927],{},"Séparez trois états de preuve : observé sur place, confirmé par un document technique fiable et encore à résoudre. Les inconnues vont dans une liste de relevé, pas sous forme de lignes certaines dans l'édition finale. Avant contrôle, le professionnel responsable décide si une investigation ou un accès supplémentaire est nécessaire.",[12,6929,6931],{"id":6930},"répercuter-chaque-modification-de-toiture","Répercuter chaque modification de toiture",[17,6933,6934],{},"Après remplacement de modules, extension de champ ou changement d'onduleur, révisez davantage que la surface du toit. Mettez à jour identifiants de champs et chaînes, trajet, point d'entrée, emplacement des appareils, références DC et AC et pièces techniques. Même si des modules sont remplacés dans une chaîne existante, conservez nombre et puissance réellement installés dans les informations du dossier. Une nouvelle répartition des chaînes doit apparaître de façon identique sur unifilaire et plan de position.",[17,6936,6937],{},"Archivez séparément l'ancienne édition avec sa date. Il devient possible de rattacher photo et rapport de contrôle au bon état. Le portail cloud de l'onduleur fournit éventuellement des données de production, mais ne remplace ni relevé spatial ni révision du plan.",[17,6939,1759,6940,6944],{},[203,6941,6943],{"href":6185,"rel":6942},[5373],"page officielle du SPF Économie sur les contrôles domestiques"," cite les sources d'énergie sur les deux plans et la documentation PV dans le dossier. Le détail nécessaire dépend de l'installation et du Livre 1 V06 actuel, pas d'un modèle de toiture générique.",[12,6946,6948],{"id":6947},"réaliser-le-plan-dans-planelec","Réaliser le plan dans PlanElec",[17,6950,6951,6952,6954],{},"Avec ",[203,6953,5823],{"href":5822},", vous placez les composants PV sur le plan de situation, saisissez la structure électrique sur l’unifilaire et exportez les deux PDF. Le logiciel reprend les données introduites. Son auto-contrôle indicatif peut signaler certaines informations prises en charge, sans remplacer le relevé sur place ou le contrôle agréé et sans certifier la conformité RGIE.",[12,6956,6958],{"id":6957},"sources-et-version","Sources et version",[17,6960,6961,6962,6965],{},"La base est la publication officielle du ",[203,6963,5835],{"href":5371,"rel":6964},[5373]," : tableau 2.23, partie 3, chapitre 7.112, dérogation étroite de la partie 8 et dossier de la partie 9. Examen selon V06 au 29 août 2026.",{"title":1212,"searchDepth":1213,"depth":1213,"links":6967},[6968,6969,6970,6971,6972,6973,6974,6980,6981,6982,6983,6984,6985,6986,6987],{"id":6642,"depth":1213,"text":6643},{"id":6675,"depth":1213,"text":6676},{"id":6706,"depth":1213,"text":6707},{"id":6733,"depth":1213,"text":6734},{"id":6752,"depth":1213,"text":6753},{"id":6782,"depth":1213,"text":6783},{"id":6811,"depth":1213,"text":6812,"children":6975},[6976,6977,6978,6979],{"id":6815,"depth":5848,"text":6816},{"id":6822,"depth":5848,"text":6823},{"id":6829,"depth":5848,"text":6830},{"id":6836,"depth":5848,"text":6837},{"id":6843,"depth":1213,"text":6844},{"id":6873,"depth":1213,"text":6874},{"id":6897,"depth":1213,"text":6898},{"id":6907,"depth":1213,"text":6908},{"id":6920,"depth":1213,"text":6921},{"id":6930,"depth":1213,"text":6931},{"id":6947,"depth":1213,"text":6948},{"id":6957,"depth":1213,"text":6958},"Localisez modules PV, onduleur, sectionnements fixes, tableaux et cheminements sur le plan de situation avec les mêmes repères que l’unifilaire.",{},"\u002Fblog\u002Fpv-situation-plan.fr",{"title":6626,"description":6988},"photovoltaique-plan-situation","blog\u002Fpv-situation-plan.fr",[6619,6995,6996,6997,1242,6998,1249],"Plan de situation","Modules PV","Onduleur","Cheminement","HmvIof4wJuEzmShL7f9c1xp5V4LSZWbA2ySZgbsw7mg",{"id":7001,"title":5396,"articleId":7002,"body":7003,"category":1228,"date":5432,"description":7384,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":7385,"navigation":1234,"path":7386,"publishDate":5432,"readTime":5436,"refreshInterval":1237,"seo":7387,"slug":7388,"stem":7389,"tags":7390,"__hash__":7393},"blog\u002Fblog\u002Fsingle-line-vs-situation-plan.fr.md","single-line-vs-situation-plan",{"type":9,"value":7004,"toc":7369},[7005,7009,7017,7020,7024,7027,7030,7034,7037,7063,7066,7069,7073,7076,7092,7095,7098,7102,7118,7128,7132,7135,7158,7161,7165,7168,7171,7174,7178,7239,7243,7246,7249,7252,7255,7259,7262,7286,7289,7306,7310,7321,7324,7331,7335,7338,7341,7343,7359,7364],[12,7006,7008],{"id":7007},"la-différence-en-une-phrase","La différence en une phrase",[17,7010,1530,7011,7013,7014,7016],{},[221,7012,1248],{}," représente les liens électriques entre alimentation, protections, canalisations et récepteurs. Le ",[221,7015,2003],{},", aussi appelé plan de situation dans l'usage courant, place les éléments dans le bâtiment. Une référence commune relie le chemin électrique à la pièce réelle.",[17,7018,7019],{},"Les deux documents sont prévus pour une nouvelle installation domestique et pour une modification ou extension importante. Ils ne sont pas interchangeables : un plan d'architecte ne décrit pas le calibre du disjoncteur, tandis qu'un circuit unifilaire ne localise pas la prise à côté de la porte.",[12,7021,7023],{"id":7022},"un-en-tête-et-une-version-cohérents","Un en-tête et une version cohérents",[17,7025,7026],{},"La sous-section 3.1.2.1 du Livre 1 V06 demande un numéro, une version et une date de version non équivoques. Les plans domestiques indiquent aussi nom et qualité du responsable de l'exécution, son numéro de TVA lorsqu'il existe, et l'adresse de l'installation. Tension et nature du courant figurent sur l'unifilaire.",[17,7028,7029],{},"Lorsque la conformité est constatée lors du contrôle, les plans sont datés et signés ou visés, puis rejoignent le rapport dans le dossier. Un PDF exporté avant cette visite n'est donc ni un plan déjà approuvé, ni un rapport positif.",[12,7031,7033],{"id":7032},"ce-que-contient-lunifilaire","Ce que contient l'unifilaire",[17,7035,7036],{},"La sous-section 3.1.2.2 énumère au minimum :",[711,7038,7039,7042,7045,7048,7051,7054,7057,7060],{},[714,7040,7041],{},"nature, section et nombre de conducteurs des canalisations ;",[714,7043,7044],{},"modes de pose ;",[714,7046,7047],{},"type et caractéristiques des dispositifs différentiels ;",[714,7049,7050],{},"type et caractéristiques des protections contre les surintensités ;",[714,7052,7053],{},"interrupteurs, boîtes de connexion et de dérivation ;",[714,7055,7056],{},"prises et points lumineux ;",[714,7058,7059],{},"machines et appareils fixes ;",[714,7061,7062],{},"sources telles que transformateur, cellule solaire, onduleur ou batterie.",[17,7064,7065],{},"Le schéma répond à des questions de structure : quel DDR précède le circuit C, quel disjoncteur protège la canalisation, comment une boîte se ramifie-t-elle et quelles charges suivent ? Il ne donne pas une position à l'échelle.",[17,7067,7068],{},"Chaque circuit élémentaire reçoit une lettre majuscule. Points lumineux, socles et unités de commande sont numérotés depuis la protection contre les surintensités située en amont. Cet ordre est électrique, pas une promenade à travers les pièces.",[12,7070,7072],{"id":7071},"ce-que-contient-le-plan-de-position","Ce que contient le plan de position",[17,7074,7075],{},"La sous-section 3.1.2.3 demande la localisation des éléments représentés sur l'unifilaire, notamment :",[711,7077,7078,7081,7084,7087,7089],{},[714,7079,7080],{},"tableaux de distribution et de manœuvre ;",[714,7082,7083],{},"boîtes de connexion et de dérivation ;",[714,7085,7086],{},"prises, points lumineux et interrupteurs ;",[714,7088,7059],{},[714,7090,7091],{},"sources, onduleurs et batteries.",[17,7093,7094],{},"Un fond de plan lisible distingue niveaux et locaux. L'échelle aide, mais l'emplacement doit surtout être univoque. Une prise dessinée au milieu de la chambre n'identifie pas correctement la paroi. Les boîtes cachées sont importantes pour la maintenance future.",[17,7096,7097],{},"Le plan de position n'est pas nécessairement un tracé complet des câbles. Le RGIE exige les emplacements précités ; il ne faut pas inventer un parcours invisible. Des câbles souterrains ou installations particulières peuvent demander des plans complémentaires.",[12,7099,7101],{"id":7100},"la-référence-commune-fait-le-lien","La référence commune fait le lien",[17,7103,7104,7105,7107,7108,2020,7111,7114,7115,7117],{},"Imaginons le circuit ",[4068,7106,3683],{}," avec trois prises et un point lumineux. L'unifilaire attribue ",[4068,7109,7110],{},"B1",[4068,7112,7113],{},"B4"," dans l'ordre électrique. Le plan place les quatre références aux emplacements réels. L'interrupteur du point ",[4068,7116,7113],{}," porte une identification qui rend cette commande explicite.",[17,7119,7120,7121,7123,7124,7127],{},"L'inspecteur peut ainsi partir du tableau vers le récepteur, puis revenir de la pièce à la protection. Si ",[4068,7122,4690],{}," manque sur le plan, sa position reste inconnue. Si une prise ",[4068,7125,7126],{},"B5"," apparaît dans la cuisine mais pas sur l'unifilaire, les documents ne décrivent pas le même état.",[12,7129,7131],{"id":7130},"produire-les-deux-à-partir-du-même-relevé","Produire les deux à partir du même relevé",[17,7133,7134],{},"Une méthode robuste est de :",[5034,7136,7137,7140,7143,7146,7149,7152,7155],{},[714,7138,7139],{},"relever étages, locaux, tableaux et sources ;",[714,7141,7142],{},"établir protections et circuits terminaux ;",[714,7144,7145],{},"rattacher chaque prise, appareil et boîte au bon circuit ;",[714,7147,7148],{},"attribuer une seule fois les références ;",[714,7150,7151],{},"compléter canalisation et caractéristiques sur le chemin électrique ;",[714,7153,7154],{},"vérifier les emplacements sur place ;",[714,7156,7157],{},"exporter les deux plans avec même version et même date de situation.",[17,7159,7160],{},"Les étiquettes du tableau sont des indices, pas une preuve. Dans l'existant, l'identification peut nécessiter une recherche sûre par une personne compétente. Une liaison cachée supposée ne devient pas vraie parce qu'elle a été dessinée proprement.",[12,7162,7164],{"id":7163},"modifications-partie-ancienne-et-historique","Modifications, partie ancienne et historique",[17,7166,7167],{},"Pour une modification non importante, une description succincte, datée et signée peut suffire à la place d'un nouvel unifilaire si les conditions du RGIE sont remplies. Toute modification ou extension est toutefois reportée sur le plan de position afin qu'il montre en permanence l'état existant. Une modification importante demande les plans actualisés correspondants.",[17,7169,7170],{},"Les parties dont l'exécution sur place a commencé avant le 1er octobre 1981 et qui apparaissent sur l'unifilaire portent la mention “partie ancienne”. Cette mention ne constitue pas une conformité générale : les dérogations réellement applicables doivent encore être examinées.",[17,7172,7173],{},"Versionnez les plans comme une paire. Un plan de position version 4 avec un unifilaire version 2 ne permet pas de savoir quel ensemble a été contrôlé. Les anciennes versions visées restent dans le dossier pour conserver l'historique.",[12,7175,7177],{"id":7176},"incohérences-typiques","Incohérences typiques",[21,7179,7180,7190],{},[24,7181,7182],{},[27,7183,7184,7187],{},[30,7185,7186],{},"Écart",[30,7188,7189],{},"Problème créé",[43,7191,7192,7207,7215,7223,7231],{},[27,7193,7194,7204],{},[48,7195,7196,7199,7200,7203],{},[4068,7197,7198],{},"C1–C6"," sur l'unifilaire, seulement ",[4068,7201,7202],{},"C1–C5"," au plan",[48,7205,7206],{},"un point n'est pas localisé ou documenté",[27,7208,7209,7212],{},[48,7210,7211],{},"lettre différente sur la même prise",[48,7213,7214],{},"lieu et protection ne se correspondent plus",[27,7216,7217,7220],{},[48,7218,7219],{},"onduleur uniquement au plan",[48,7221,7222],{},"source et chaîne de protection manquent",[27,7224,7225,7228],{},[48,7226,7227],{},"boîte uniquement sur l'unifilaire",[48,7229,7230],{},"sa position physique est inconnue",[27,7232,7233,7236],{},[48,7234,7235],{},"adresse ou version différente",[48,7237,7238],{},"les fichiers peuvent représenter deux états distincts",[12,7240,7242],{"id":7241},"utilisation-pendant-le-contrôle","Utilisation pendant le contrôle",[17,7244,7245],{},"L'organisme agréé vérifie notamment si l'exécution correspond au schéma unifilaire et au plan de position. L'unifilaire rend protections et canalisations traçables ; le plan permet de retrouver les points sur place. Mesures et examen visuel complètent cette comparaison.",[17,7247,7248],{},"Deux plans cohérents peuvent encore contenir une erreur de conception. Inversement, une partie techniquement correcte reste mal documentée si les plans se contredisent. Séparez donc trois validations : dossier complet, étude professionnelle et contrôle officiel de l'exécution. Aucune ne découle automatiquement d'un PDF propre.",[17,7250,7251],{},"Après un résultat conforme, le propriétaire reçoit plans visés et rapport pour son dossier. L'organisme conserve une copie pendant la période réglementée, sans retirer au propriétaire son obligation de maintenir sa propre version à jour.",[17,7253,7254],{},"La copie de l'organisme est un filet de sécurité, pas un système de versionnage. Une modification conservée uniquement sur une feuille séparée rend de nouveau l'ensemble ambigu. Rattachez chaque évolution à la bonne version des deux plans.",[12,7256,7258],{"id":7257},"une-réconciliation-pratique-avant-validation","Une réconciliation pratique avant validation",[17,7260,7261],{},"Ne comparez pas seulement les pages côte à côte. Travaillez circuit par circuit. Partez de la liste des lettres, suivez chaque circuit depuis sa protection jusqu'au dernier récepteur et posez les mêmes questions aux deux documents : quels points existent, quel repère portent-ils, où se trouvent-ils et quelle fonction fixe remplissent-ils ? Notez toute différence comme tâche ouverte au lieu de la masquer sous un nom de local général.",[17,7263,7264,7265,7268,7269,7272,7273,7276,7277,7279,7280,7282,7283,7285],{},"Pour le circuit ",[4068,7266,7267],{},"H",", la liste pourrait contenir le plafonnier ",[4068,7270,7271],{},"H1",", l'applique ",[4068,7274,7275],{},"H2"," et leurs interrupteurs. L'unifilaire montre leur position électrique derrière protection et canalisation. Le plan de position situe ",[4068,7278,7271],{}," dans le hall et ",[4068,7281,7275],{}," dehors. Si ",[4068,7284,7275],{}," manque sur une feuille, l'autre n'est pas automatiquement exacte : confrontez relevé et installation exécutée, puis corrigez les deux documents.",[17,7287,7288],{},"Effectuez aussi des contrôles transversaux :",[711,7290,7291,7294,7297,7300,7303],{},[714,7292,7293],{},"chaque tableau et source fixe de l'unifilaire possède un emplacement repérable ;",[714,7295,7296],{},"les boîtes de connexion et de dérivation pertinentes gardent le même identifiant ;",[714,7298,7299],{},"une machine fixe n'est pas réduite au nom du local ;",[714,7301,7302],{},"chaque renvoi entre feuilles aboutit au bon circuit, pas à un groupe au nom voisin ;",[714,7304,7305],{},"en-tête, adresse, pagination, date et indice forment un jeu documentaire identifiable.",[12,7307,7309],{"id":7308},"exemple-enregistrer-une-petite-extension","Exemple : enregistrer une petite extension",[17,7311,7312,7313,7316,7317,7320],{},"Lorsqu'une prise est ajoutée dans un bureau, déterminez d'abord le circuit auquel elle a réellement été raccordée. Si elle est le point suivant du circuit ",[4068,7314,7315],{},"D",", elle peut devenir ",[4068,7318,7319],{},"D6"," ; inscrivez ce repère à sa position électrique sur l'unifilaire et à sa position physique sur le plan. Ne déduisez pas canalisation et protection de la prise graphiquement la plus proche. Vérifiez le raccordement réel et augmentez ensemble date et indice des deux feuilles.",[17,7322,7323],{},"Pour une modification non importante, le RGIE peut permettre une description succincte au lieu d'un nouvel unifilaire, tandis que le plan de position doit toujours reprendre les modifications et l'état existant des éléments. Qualifier les travaux d'importants ou non demande une appréciation compétente. N'utilisez pas cette disposition pour accumuler des interventions non reportées pendant des années. Dès que l'affectation ou l'état actuel n'est plus clair, consolidez les plans.",[17,7325,1759,7326,7330],{},[203,7327,7329],{"href":6185,"rel":7328},[5373],"page officielle du SPF Économie sur le contrôle des installations domestiques"," résume le contenu et le lien entre les deux documents. Le Livre 1 officiel à jour reste déterminant ; ses exemples guident la présentation, mais ne se copient pas sans relevé.",[12,7332,7334],{"id":7333},"le-rôle-exact-de-planelec","Le rôle exact de PlanElec",[17,7336,7337],{},"PlanElec rassemble positions du fond de plan et topologie électrique dans un projet. Il permet d'exporter unifilaire et plan de position en PDF ; l'auto-contrôle indicatif examine uniquement les règles prises en charge et décidables avec les données saisies. Une base commune limite la double saisie sans garantir la justesse du relevé.",[17,7339,7340],{},"PlanElec ne voit pas les câbles cachés, ne réalise aucune mesure et ne vise aucun plan. Affectations, caractéristiques et canalisations doivent être contrôlées professionnellement. Le contrôle officiel appartient à un organisme agréé.",[12,7342,4945],{"id":4944},[711,7344,7345,7349,7354],{},[714,7346,7347],{},[203,7348,4953],{"href":4952},[714,7350,7351],{},[203,7352,7353],{"href":4177},"Checklist de l'unifilaire d'une construction neuve",[714,7355,7356],{},[203,7357,7358],{"href":1966},"Dessiner un plan de position étape par étape",[17,7360,7361],{},[203,7362,7363],{"href":1204},"Ouvrir PlanElec pour préparer et exporter les deux plans →",[17,7365,7366],{},[60,7367,7368],{},"Référence : RGIE Livre 1 V06, section 3.1.2 et section 9.1.2. Le texte officiel, l'état réel et le contrôle de l'organisme agréé restent déterminants.",{"title":1212,"searchDepth":1213,"depth":1213,"links":7370},[7371,7372,7373,7374,7375,7376,7377,7378,7379,7380,7381,7382,7383],{"id":7007,"depth":1213,"text":7008},{"id":7022,"depth":1213,"text":7023},{"id":7032,"depth":1213,"text":7033},{"id":7071,"depth":1213,"text":7072},{"id":7100,"depth":1213,"text":7101},{"id":7130,"depth":1213,"text":7131},{"id":7163,"depth":1213,"text":7164},{"id":7176,"depth":1213,"text":7177},{"id":7241,"depth":1213,"text":7242},{"id":7257,"depth":1213,"text":7258},{"id":7308,"depth":1213,"text":7309},{"id":7333,"depth":1213,"text":7334},{"id":4944,"depth":1213,"text":4945},"L’unifilaire décrit les circuits et protections, le plan de position localise les éléments. Les mêmes références rendent les deux documents RGIE cohérents.",{},"\u002Fblog\u002Fsingle-line-vs-situation-plan.fr",{"title":5396,"description":7384},"schema-unifilaire-vs-plan-situation","blog\u002Fsingle-line-vs-situation-plan.fr",[1243,1242,1248,2003,7391,7392,1249],"circuit","dossier électrique","EoB0_BMWN3-8bHkgA2kQM2Z3SS8vhSl5B9wOGl1gahs",{"id":7395,"title":7396,"articleId":7397,"body":7398,"category":1228,"date":7915,"description":7916,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":7917,"navigation":1234,"path":7918,"publishDate":7915,"readTime":7919,"refreshInterval":7920,"seo":7921,"slug":7922,"stem":7923,"tags":7924,"__hash__":7933},"blog\u002Fblog\u002Fsynergrid-c10-26-list.fr.md","Liste Synergrid C10\u002F26 : mon onduleur est-il sur la liste – et sinon ?","synergrid-c10-26-list",{"type":9,"value":7399,"toc":7898},[7400,7415,7419,7426,7435,7439,7493,7500,7504,7511,7618,7622,7629,7633,7687,7691,7699,7703,7746,7750,7756,7782,7785,7789,7798,7802,7812,7818,7824,7830,7832,7848,7851,7863,7867,7870,7878,7881,7884,7891,7895],[17,7401,7402,7405,7406,7409,7410,7414],{},[221,7403,7404],{},"Réponse courte :"," la liste Synergrid C10\u002F26 est le registre belge de tous les onduleurs, onduleurs hybrides et systèmes de stockage homologués selon la prescription technique C10\u002F11 (annexe D). En règle générale, les gestionnaires de réseau (Fluvius, ORES, RESA, Sibelga) n'acceptent à la déclaration que des appareils repris sur la liste – dans la ",[221,7407,7408],{},"version de firmware"," indiquée. Si un appareil n'est pas listé, il ne reste que la preuve de conformité individuelle selon la C10\u002F11, que le gestionnaire de réseau doit accepter. Pour savoir si un appareil y figure, utilisez gratuitement la ",[203,7411,7413],{"href":7412},"\u002Ffr\u002Ftools\u002Fverification-onduleur-synergrid-c10-26","vérification Synergrid C10\u002F26 de PlanElec"," – les données sont comparées à la liste officielle ; vérifiez la date des données affichée.",[12,7416,7418],{"id":7417},"quest-ce-que-la-liste-synergrid-c1026","Qu'est-ce que la liste Synergrid C10\u002F26 ?",[17,7420,7421,7422,7425],{},"Synergrid est la fédération des gestionnaires belges de réseaux d'électricité et de gaz. La prescription ",[221,7423,7424],{},"C10\u002F11"," fixe les exigences techniques que les unités de production décentralisées (onduleurs PV, batteries domestiques, cogénération, éolien) doivent respecter sur le réseau basse tension : fonctions de protection en cas de perturbation, comportement en fréquence et en tension, régulation de puissance.",[17,7427,1759,7428,7431,7432,212],{},[221,7429,7430],{},"liste C10\u002F26"," en est la traduction pratique : les fabricants font tester leurs appareils selon la C10\u002F11 ; les types approuvés sont publiés avec numéro de référence, version de firmware et caractéristiques techniques. Synergrid met la liste à jour en continu sous forme de fichier Excel ; la version actuelle se réfère à la ",[221,7433,7434],{},"C10\u002F11 édition 2.4 (15\u002F10\u002F2025)",[12,7436,7438],{"id":7437},"pourquoi-la-liste-compte-pour-la-déclaration-et-le-contrôle","Pourquoi la liste compte pour la déclaration et le contrôle",[21,7440,7441,7451],{},[24,7442,7443],{},[27,7444,7445,7448],{},[30,7446,7447],{},"Étape",[30,7449,7450],{},"Rôle de la liste C10\u002F26",[43,7452,7453,7463,7473,7483],{},[27,7454,7455,7460],{},[48,7456,7457],{},[221,7458,7459],{},"Déclaration au gestionnaire de réseau",[48,7461,7462],{},"Fluvius, ORES, RESA et Sibelga exigent un appareil de la liste ; le type d'onduleur est demandé dans le formulaire de déclaration",[27,7464,7465,7470],{},[48,7466,7467],{},[221,7468,7469],{},"Contrôle de conformité",[48,7471,7472],{},"L'organisme de contrôle confronte l'onduleur au schéma unifilaire et aux données du fabricant",[27,7474,7475,7480],{},[48,7476,7477],{},[221,7478,7479],{},"Autorisation d'injection",[48,7481,7482],{},"Sans appareil homologué, le gestionnaire de réseau n'autorise pas l'injection",[27,7484,7485,7490],{},[48,7486,7487],{},[221,7488,7489],{},"Mise à jour du firmware ou remplacement",[48,7491,7492],{},"Une nouvelle version de firmware ou un appareil de remplacement doit à nouveau figurer sur la liste",[17,7494,7495,7496,7499],{},"Pour les installations PV domestiques jusqu'à 10 kVA, l'art. 7.112 du RGIE s'applique en outre (exigences portant sur l'installation électrique elle-même) – les deux doivent être respectés. Le guide ",[203,7497,7498],{"href":6354},"Panneaux solaires dans le schéma unifilaire"," décrit le schéma correspondant.",[12,7501,7503],{"id":7502},"comment-lire-une-ligne-de-la-liste","Comment lire une ligne de la liste",[17,7505,7506,7507,7510],{},"Chaque ligne décrit ",[221,7508,7509],{},"une combinaison modèle + firmware",". Les colonnes essentielles :",[21,7512,7513,7523],{},[24,7514,7515],{},[27,7516,7517,7520],{},[30,7518,7519],{},"Colonne",[30,7521,7522],{},"Signification",[43,7524,7525,7538,7548,7558,7568,7578,7588,7598,7608],{},[27,7526,7527,7535],{},[48,7528,7529,7531,7532,306],{},[221,7530,426],{}," (p. ex. ",[4068,7533,7534],{},"GLV052-09-0003",[48,7536,7537],{},"Numéro d'homologation Synergrid de l'appareil – complète la marque et le modèle dans la déclaration (pas toujours univoque par modèle)",[27,7539,7540,7545],{},[48,7541,7542],{},[221,7543,7544],{},"Marque \u002F série \u002F modèle",[48,7546,7547],{},"Désignation du fabricant, exactement comme sur la plaque signalétique",[27,7549,7550,7555],{},[48,7551,7552],{},[221,7553,7554],{},"Firmware",[48,7556,7557],{},"Version logicielle testée ; l'homologation ne vaut que pour cette version",[27,7559,7560,7565],{},[48,7561,7562],{},[221,7563,7564],{},"Pac,r (W)",[48,7566,7567],{},"Puissance active nominale à la sortie AC",[27,7569,7570,7575],{},[48,7571,7572],{},[221,7573,7574],{},"Smax (VA)",[48,7576,7577],{},"Puissance apparente maximale – déterminante pour la classe de puissance ; les gestionnaires de réseau limitent généralement les unités monophasées à environ 5 kVA (vérifier le seuil exact auprès du gestionnaire de réseau)",[27,7579,7580,7585],{},[48,7581,7582],{},[221,7583,7584],{},"Phases",[48,7586,7587],{},"Monophasé ou triphasé",[27,7589,7590,7595],{},[48,7591,7592],{},[221,7593,7594],{},"Application",[48,7596,7597],{},"Solaire, stockage, cogénération, éolien, secours",[27,7599,7600,7605],{},[48,7601,7602],{},[221,7603,7604],{},"Restrictions",[48,7606,7607],{},"Conditions sous lesquelles l'appareil est admis (voir ci-dessous)",[27,7609,7610,7615],{},[48,7611,7612],{},[221,7613,7614],{},"Homologué depuis",[48,7616,7617],{},"Date de l'homologation définitive (ou provisoire)",[5686,7619,7621],{"id":7620},"pourquoi-la-version-de-firmware-compte","Pourquoi la version de firmware compte",[17,7623,7624,7625,7628],{},"Les fonctions de protection selon la C10\u002F11 sont logicielles. Un appareil dont le firmware diffère de la version listée est considéré comme ",[221,7626,7627],{},"non homologué"," lors de la déclaration et du contrôle – même si le modèle figure sur la liste. Vérifiez la version sur l'appareil ou dans l'application du fabricant et comparez-la à la ligne de la liste.",[5686,7630,7632],{"id":7631},"interpréter-correctement-les-restrictions","Interpréter correctement les restrictions",[21,7634,7635,7645],{},[24,7636,7637],{},[27,7638,7639,7642],{},[30,7640,7641],{},"Restriction sur la liste",[30,7643,7644],{},"Ce qu'elle signifie",[43,7646,7647,7657,7667,7677],{},[27,7648,7649,7654],{},[48,7650,7651],{},[221,7652,7653],{},"Uniquement dans un module \u003C 800 W",[48,7655,7656],{},"Admis uniquement comme élément d'une unité de production prête à brancher (kit plug-and-play, batterie plug-in)",[27,7658,7659,7664],{},[48,7660,7661],{},[221,7662,7663],{},"Uniquement pour petites unités de production",[48,7665,7666],{},"Pas pour les installations plus importantes soumises à des exigences étendues",[27,7668,7669,7674],{},[48,7670,7671],{},[221,7672,7673],{},"Uniquement raccordement haute tension",[48,7675,7676],{},"Pas pour les raccordements domestiques au réseau basse tension",[27,7678,7679,7684],{},[48,7680,7681],{},[221,7682,7683],{},"Uniquement comme système de secours",[48,7685,7686],{},"Homologué uniquement pour l'alimentation de secours, pas pour l'injection dans le réseau – l'appareil alimente une partie isolée de l'installation en cas de panne",[12,7688,7690],{"id":7689},"kit-plug-and-play-et-batterie-plug-in-la-même-liste","Kit plug-and-play et batterie plug-in : la même liste",[17,7692,7693,7694,7698],{},"Les micro-onduleurs et batteries plug-in jusqu'à 800 W – Marstek, Zendure, Anker Solix, HomeWizard ou Hoymiles par exemple – doivent eux aussi figurer sur la liste C10\u002F26, le plus souvent avec la restriction « uniquement en module \u003C 800 W ». Un appareil vendu en Allemagne ou aux Pays-Bas n'est donc pas automatiquement admis en Belgique : les réglages de protection réseau belges (C10\u002F11) diffèrent, et le fabricant doit faire homologuer séparément la variante belge. Vérifiez donc avant l'achat que le modèle précis est listé. Même listé, un appareil plug-and-play doit être déclaré au gestionnaire de réseau ; l'installation électrique elle-même reste soumise au RGIE. Si vous cherchez précisément une batterie, utilisez la ",[203,7695,7697],{"href":7696},"\u002Ffr\u002Ftools\u002Fverification-batterie-domestique-synergrid","vérification Synergrid C10\u002F26 pour batteries domestiques"," – la même liste, mais rédigée pour les batteries et les onduleurs hybrides.",[12,7700,7702],{"id":7701},"erreurs-fréquentes-sur-le-terrain","Erreurs fréquentes sur le terrain",[5034,7704,7705,7718,7724,7730,7736],{},[714,7706,7707,7710,7711,207,7714,7717],{},[221,7708,7709],{},"Modèle vérifié sans suffixe"," – ",[4068,7712,7713],{},"SUN2000-8KTL-M0",[4068,7715,7716],{},"SUN2000-8KTL-M1"," sont des lignes différentes.",[714,7719,7720,7723],{},[221,7721,7722],{},"Firmware non comparé"," – l'appareil est listé, mais installé avec une version plus ancienne.",[714,7725,7726,7729],{},[221,7727,7728],{},"Homologation expirée ignorée"," – Synergrid retire des lignes ; l'appareil apparaît alors sous « expired ».",[714,7731,7732,7735],{},[221,7733,7734],{},"Importation de l'étranger"," – même nom, autre variante nationale sans homologation belge.",[714,7737,7738,7741,7742,212],{},[221,7739,7740],{},"Batterie oubliée"," – l'onduleur de batterie doit lui aussi figurer sur la liste, pas seulement l'onduleur PV. Voir ",[203,7743,7745],{"href":7744},"\u002Ffr\u002Fblog\u002Fbatterie-domestique-rgie","Batterie domestique et RGIE",[12,7747,7749],{"id":7748},"vérifier-un-appareil-en-quelques-secondes","Vérifier un appareil en quelques secondes",[17,7751,1759,7752,7755],{},[203,7753,7754],{"href":7412},"vérification Synergrid C10\u002F26"," charge une copie datée de la liste officielle et la rend consultable :",[5034,7757,7758,7764,7770,7776],{},[714,7759,7760,7763],{},[221,7761,7762],{},"Tapez la marque"," – les suggestions indiquent combien de modèles sont listés par marque.",[714,7765,7766,7769],{},[221,7767,7768],{},"Affinez le modèle"," – continuez à taper jusqu'au modèle exact ; les lignes expirées sont signalées.",[714,7771,7772,7775],{},[221,7773,7774],{},"Lisez le résultat"," – le tableau affiche firmware, Smax, Pac, phases, application, restrictions et la référence Synergrid ; triable et filtrable par phases, segment et statut.",[714,7777,7778,7781],{},[221,7779,7780],{},"Pas de résultat ?"," – l'outil propose des appareils homologués techniquement comparables de la même classe de puissance.",[17,7783,7784],{},"Les filtres et le tri sont repris dans l'URL ; le lien se transmet tel quel à un client ou un collègue.",[12,7786,7788],{"id":7787},"limites-de-loutil","Limites de l'outil",[17,7790,7791,7792,7797],{},"L'outil est une aide à la recherche, pas une attestation officielle. La ",[203,7793,7796],{"href":7794,"rel":7795},"https:\u002F\u002Fwww.synergrid.be\u002Fnl\u002Fhomologatie\u002Felektriciteit\u002Fdecentrale-productie-eenheden",[5373],"liste officielle sur synergrid.be"," fait foi ; en cas de divergence, la liste officielle prévaut. L'outil ne contrôle pas l'installation électrique elle-même (protection, différentiel, section de câble, sectionneur) – c'est le rôle de l'autocontrôle RGIE dans le schéma unifilaire de PlanElec.",[12,7799,7801],{"id":7800},"questions-fréquentes","Questions fréquentes",[17,7803,7804,7807,7808,7811],{},[221,7805,7806],{},"Dois-je indiquer la référence Synergrid dans la déclaration ?","\nLes gestionnaires de réseau demandent avant tout la marque, le modèle et la version de firmware. La référence GLV est un complément utile, mais pas toujours univoque par modèle : Synergrid attribue parfois la même référence à plusieurs modèles. Indiquez donc la référence ",[221,7809,7810],{},"et"," la désignation du modèle.",[17,7813,7814,7817],{},[221,7815,7816],{},"Mon appareil est listé, mais la ligne est « expired » – que faire ?","\nL'homologation a été retirée ou est arrivée à échéance. Pour une nouvelle installation, l'appareil n'est plus admis ; les installations existantes ne sont en général pas concernées. En cas de doute, interrogez le gestionnaire de réseau.",[17,7819,7820,7823],{},[221,7821,7822],{},"La liste vaut-elle aussi pour la Wallonie et Bruxelles ?","\nOui. C10\u002F11 et C10\u002F26 sont des prescriptions Synergrid valables dans tout le pays pour tous les gestionnaires de réseau de distribution.",[17,7825,7826,7829],{},[221,7827,7828],{},"À quelle fréquence la liste change-t-elle ?","\nSynergrid publie régulièrement de nouvelles versions ; l'outil affiche la date des données importées et affiche la date des données.",[12,7831,5389],{"id":5388},[711,7833,7834,7839,7843],{},[714,7835,7836],{},[203,7837,7838],{"href":6354},"Documenter les panneaux solaires dans le schéma unifilaire",[714,7840,7841],{},[203,7842,7745],{"href":7744},[714,7844,7845],{},[203,7846,7847],{"href":6216},"Contrôle électrique en Belgique",[7849,7850],"hr",{},[17,7852,7853],{},[60,7854,7855,7856,7858,7859],{},"Planifiez installation PV et batterie avec ",[221,7857,5823],{}," dans le schéma unifilaire – onduleur, protections et documents de déclaration au même endroit. ",[203,7860,7862],{"href":7861},"\u002F","Commencer →",[12,7864,7866],{"id":7865},"vérification-défendable-étape-par-étape","Vérification défendable, étape par étape",[17,7868,7869],{},"Partez de l'étiquette de l'appareil réellement prévu, pas du titre d'une boutique. Relevez fabricant, suffixe complet, référence, puissance apparente et firmware. Une famille hybride peut contenir plusieurs puissances, variantes régionales ou branches logicielles. Un résultat limité à la marque ou au début du nom ne suffit pas.",[17,7871,7872,7873,7877],{},"Ouvrez la ",[203,7874,7876],{"href":6589,"rel":7875},[5373],"page d'homologation Synergrid"," et la liste officielle liée. Comparez chaque champ et lisez les restrictions : modes, protection externe, limitation d'injection, stockage ou combinaison de composants. Pour le Plug & Play, consultez la page et l'entrée dédiées ; une homologation de production classique ne couvre pas implicitement toute configuration à brancher.",[17,7879,7880],{},"Conservez dans le projet la ligne ou référence officielle, la date de liste, le firmware lu sur place et la date de vérification. Recommencez avant mise en service et déclaration, car appareil, firmware ou données peuvent changer entre devis et pose. En l'absence de ligne, demandez au fabricant ou importateur de clarifier l'homologation belge et au gestionnaire concerné quel justificatif il accepte. La recherche PlanElec facilite la lecture sans constituer une attestation ; la source officielle prévaut.",[17,7882,7883],{},"Séparez trois décisions. L'homologation C10\u002F26 vise l'interface réseau du type de produit. L'organisme agréé contrôle l'installation selon le RGIE. Le gestionnaire traite déclaration et conditions de raccordement. Un résultat positif ne délivre pas automatiquement les deux autres.",[17,7885,7886,7887,7890],{},"Le schéma unifilaire reprend l'onduleur exact, protections, sectionnements et câbles. Plan de position, déclarations fabricant, mise en service et rapport rejoignent le dossier. Voir ",[203,7888,7889],{"href":6354},"documenter une installation PV",". Révision effectuée le 29 août 2026 ; utilisez toujours la liste officielle en direct avant achat ou mise en service.",[5686,7892,7894],{"id":7893},"des-lignes-proches-ne-sont-pas-interchangeables","Des lignes proches ne sont pas interchangeables",[17,7896,7897],{},"Comparez variante électrique, firmware, Smax et remarques en plus du nom. Conservez référence officielle et date, pas seulement une capture. Un ensemble onduleur, batterie et protection externe peut demander plusieurs preuves. Revérifiez après mise à jour. Le marquage CE n'est pas l'homologation C10\u002F26 et aucun des deux ne remplace le contrôle. Pour une configuration sans injection, documentez composants et réglages ; la limitation n'efface pas automatiquement les obligations de raccordement. Faites clarifier les cas limites avant commande.",{"title":1212,"searchDepth":1213,"depth":1213,"links":7899},[7900,7901,7902,7906,7907,7908,7909,7910,7911,7912],{"id":7417,"depth":1213,"text":7418},{"id":7437,"depth":1213,"text":7438},{"id":7502,"depth":1213,"text":7503,"children":7903},[7904,7905],{"id":7620,"depth":5848,"text":7621},{"id":7631,"depth":5848,"text":7632},{"id":7689,"depth":1213,"text":7690},{"id":7701,"depth":1213,"text":7702},{"id":7748,"depth":1213,"text":7749},{"id":7787,"depth":1213,"text":7788},{"id":7800,"depth":1213,"text":7801},{"id":5388,"depth":1213,"text":5389},{"id":7865,"depth":1213,"text":7866,"children":7913},[7914],{"id":7893,"depth":5848,"text":7894},"2026-08-26","Ce qu'est la liste Synergrid C10\u002F26, pourquoi les gestionnaires de réseau et les organismes de contrôle l'exigent, comment lire référence, firmware, Smax et restrictions – et comment vérifier un appareil en quelques secondes.",{},"\u002Fblog\u002Fsynergrid-c10-26-list.fr","7 min",6,{"title":7396,"description":7916},"liste-synergrid-c10-26-onduleur","blog\u002Fsynergrid-c10-26-list.fr",[7925,7926,7927,7928,7929,7930,7931,7932],"synergrid","c10\u002F26","onduleur","panneaux solaires","pv","batterie domestique","kit plug-and-play","déclaration gestionnaire de réseau","Obp8M7_c6qAIpeZvdJUJD-DGQLSOQ8QBivur1xw-gjA",{"id":7935,"title":7936,"articleId":7937,"body":7938,"category":8411,"date":8412,"description":8413,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":8414,"navigation":1234,"path":8415,"publishDate":8412,"readTime":8416,"refreshInterval":5848,"seo":8417,"slug":8418,"stem":8419,"tags":8420,"__hash__":8424},"blog\u002Fblog\u002Falternative-trikker.fr.md","PlanElec comme alternative à Trikker : un comparatif","planelec-vs-trikker",{"type":9,"value":7939,"toc":8396},[7940,7943,7946,7950,8180,8196,8200,8203,8209,8215,8221,8227,8231,8234,8240,8246,8249,8252,8256,8259,8265,8271,8277,8283,8287,8291,8294,8298,8305,8309,8312,8316,8319,8321,8327,8333,8339,8345,8351,8357,8359,8383,8387],[17,7941,7942],{},"PlanElec est une alternative à Trikker fonctionnant dans le navigateur, pour établir schémas unifilaires et plans de situation d'installations belges. Trikker fonctionne sous Windows et coûte 45 € par mois HTVA. PlanElec fonctionne dans tout navigateur et est actuellement gratuit pendant l'Early Access. Qui travaille entièrement hors ligne reste mieux servi par Trikker.",[17,7944,7945],{},"Ce comparatif est rédigé par l'équipe de PlanElec. Les données relatives à Trikker proviennent de leur propre site, avec la source et la date de vérification, afin que vous puissiez contrôler chaque point vous-même.",[12,7947,7949],{"id":7948},"comparatif-en-un-coup-dœil","Comparatif en un coup d'œil",[21,7951,7952,7964],{},[24,7953,7954],{},[27,7955,7956,7959,7961],{},[30,7957,7958],{},"Critère",[30,7960,5823],{},[30,7962,7963],{},"Trikker",[43,7965,7966,7978,7991,8004,8017,8030,8043,8056,8067,8077,8090,8103,8116,8129,8142,8155,8168],{},[27,7967,7968,7973,7975],{},[48,7969,7970],{},[221,7971,7972],{},"Éditeur",[48,7974,5823],{},[48,7976,7977],{},"Bluebits BV",[27,7979,7980,7985,7988],{},[48,7981,7982],{},[221,7983,7984],{},"Plateforme",[48,7986,7987],{},"Navigateur — Windows, macOS, Linux, iPad",[48,7989,7990],{},"Windows ; macOS annoncé pour la fin de l'été 2026, version web ensuite",[27,7992,7993,7998,8001],{},[48,7994,7995],{},[221,7996,7997],{},"Installation",[48,7999,8000],{},"Aucune",[48,8002,8003],{},"Installation puis activation via serveur de licences",[27,8005,8006,8011,8014],{},[48,8007,8008],{},[221,8009,8010],{},"Plusieurs appareils",[48,8012,8013],{},"Oui, avec le même compte",[48,8015,8016],{},"Une licence vaut pour un PC à la fois",[27,8018,8019,8024,8027],{},[48,8020,8021],{},[221,8022,8023],{},"Langues",[48,8025,8026],{},"Néerlandais, français, allemand, anglais",[48,8028,8029],{},"Néerlandais, français, anglais",[27,8031,8032,8037,8040],{},[48,8033,8034],{},[221,8035,8036],{},"Prix",[48,8038,8039],{},"Early Access, actuellement gratuit",[48,8041,8042],{},"45 €\u002Fmois ou 360 €\u002Fan, HTVA",[27,8044,8045,8050,8053],{},[48,8046,8047],{},[221,8048,8049],{},"Essai gratuit",[48,8051,8052],{},"Toutes les fonctions pendant l'Early Access",[48,8054,8055],{},"Démo : max. 5 circuits, 1 page de plan de situation, filigrane",[27,8057,8058,8062,8065],{},[48,8059,8060],{},[221,8061,5869],{},[48,8063,8064],{},"Oui",[48,8066,8064],{},[27,8068,8069,8073,8075],{},[48,8070,8071],{},[221,8072,6995],{},[48,8074,8064],{},[48,8076,8064],{},[27,8078,8079,8084,8087],{},[48,8080,8081],{},[221,8082,8083],{},"Plan du bâtiment",[48,8085,8086],{},"Dessin dans l'application, ou plan DXF en arrière-plan",[48,8088,8089],{},"Import AutoCAD DWG ou DXF en arrière-plan",[27,8091,8092,8097,8100],{},[48,8093,8094],{},[221,8095,8096],{},"Plusieurs plans sur une planche",[48,8098,8099],{},"Marqués comme extraits à l'import, un étage par extrait",[48,8101,8102],{},"Non prévu",[27,8104,8105,8110,8113],{},[48,8106,8107],{},[221,8108,8109],{},"Échelle à l'import",[48,8111,8112],{},"Reprise du fichier ; à défaut d'unité, une confirmation",[48,8114,8115],{},"L'arrière-plan se place comme une image",[27,8117,8118,8123,8126],{},[48,8119,8120],{},[221,8121,8122],{},"Répartition du tableau",[48,8124,8125],{},"Partie distincte du projet",[48,8127,8128],{},"Intégrée au schéma",[27,8130,8131,8136,8139],{},[48,8132,8133],{},[221,8134,8135],{},"Autocontrôle RGIE",[48,8137,8138],{},"Aide à la conception, pas un contrôle officiel",[48,8140,8141],{},"Appréciation par l'auteur du plan",[27,8143,8144,8149,8152],{},[48,8145,8146],{},[221,8147,8148],{},"Travail hors ligne",[48,8150,8151],{},"Non, connexion internet requise",[48,8153,8154],{},"Oui, hors ligne un certain temps après activation",[27,8156,8157,8162,8165],{},[48,8158,8159],{},[221,8160,8161],{},"Maturité",[48,8163,8164],{},"Récent, base d'utilisateurs réduite",[48,8166,8167],{},"Produit établi ; chiffres actuels sur le site de l'éditeur",[27,8169,8170,8175,8178],{},[48,8171,8172],{},[221,8173,8174],{},"Reprise des fichiers",[48,8176,8177],{},"Pas d'import de fichiers Trikker",[48,8179,3402],{},[17,8181,8182],{},[60,8183,8184,8185,207,8190,8195],{},"Données Trikker vérifiées le 20 août 2026 sur ",[203,8186,8189],{"href":8187,"rel":8188},"https:\u002F\u002Fwww.trikker.be\u002F",[5373],"trikker.be",[203,8191,8194],{"href":8192,"rel":8193},"https:\u002F\u002Fwww.trikker.be\u002Fpricing",[5373],"trikker.be\u002Fpricing",". Prix et fonctions peuvent évoluer. Si vous constatez un écart, signalez-le-nous — nous adaptons ce tableau.",[12,8197,8199],{"id":8198},"pourquoi-des-électriciens-cherchent-une-alternative","Pourquoi des électriciens cherchent une alternative",[17,8201,8202],{},"Trikker est depuis plus de quinze ans la référence établie pour les schémas unifilaires en Belgique. Ceux qui cherchent une alternative ne le font généralement pas parce que le programme fonctionne mal, mais parce que leur façon de travailler ne correspond plus à un poste fixe.",[17,8204,8205,8208],{},[221,8206,8207],{},"Travailler sur plusieurs appareils."," Une licence Trikker vaut pour un PC à la fois. En changeant d'ordinateur, vous ressaisissez votre code de licence ; s'il est encore actif sur un autre appareil, il doit d'abord y être libéré. Qui alterne entre bureau, domicile et chantier s'y heurte régulièrement.",[17,8210,8211,8214],{},[221,8212,8213],{},"Pas de Windows."," Trikker fonctionne aujourd'hui sous Windows. Une version macOS est annoncée pour la fin de l'été 2026, une version web devrait suivre. Qui travaille déjà sur Mac ou iPad n'a pas de solution opérationnelle actuellement.",[17,8216,8217,8220],{},[221,8218,8219],{},"Le coût pour quelques schémas par an."," 45 € par mois ou 360 € par an représentent un investissement justifié pour un usage quotidien. Pour une entreprise qui établit quelques schémas par an, ou pour un propriétaire avec un seul dossier de vente, le calcul est différent.",[17,8222,8223,8226],{},[221,8224,8225],{},"Installateurs germanophones."," Trikker est proposé en néerlandais, français et anglais. Dans les Cantons de l'Est, une partie des installateurs travaille en allemand. PlanElec est disponible en quatre langues, allemand compris.",[12,8228,8230],{"id":8229},"la-vraie-différence-dessiner-ou-concevoir","La vraie différence : dessiner ou concevoir",[17,8232,8233],{},"C'est là que se situe la différence de fond entre les deux programmes, et c'est elle qui détermine si PlanElec constitue une amélioration pour vous ou non.",[17,8235,8236,8239],{},[221,8237,8238],{},"Trikker est un logiciel de dessin."," Vous glissez les symboles RGIE sur une feuille et construisez ainsi votre schéma unifilaire et votre plan de situation. Vous décidez de la structure, vous gardez la vue d'ensemble, et le résultat correspond exactement à ce que vous avez dessiné. Cela donne un contrôle total, et pour qui maîtrise la norme, le travail avance vite.",[17,8241,8242,8245],{},[221,8243,8244],{},"PlanElec part d'un modèle de projet."," Vous dessinez d'abord le plan du bâtiment, y placez les consommateurs, définissez les circuits et répartissez le tableau. Le schéma unifilaire en est déduit. Si vous ajoutez ensuite une prise ou un circuit, la représentation est reconstruite sans que vous ayez à redessiner le schéma à la main.",[17,8247,8248],{},"Cette différence a deux conséquences. Plan, circuits, tableau et schéma ne peuvent pas diverger, puisqu'ils proviennent des mêmes données — avec deux dessins séparés, cette cohérence est à votre charge. En contrepartie, vous êtes moins libre dans la mise en page : ce que le modèle ne connaît pas, vous ne pouvez pas non plus le dessiner.",[17,8250,8251],{},"Pour qui intègre des modifications tout au long d'une rénovation, le modèle de projet représente l'avantage pratique le plus net. Pour qui établit un schéma une seule fois sans y revenir, cet avantage pèse moins lourd.",[12,8253,8255],{"id":8254},"quand-trikker-reste-le-meilleur-choix","Quand Trikker reste le meilleur choix",[17,8257,8258],{},"Certaines situations nous amènent à recommander Trikker, bien que nous soyons concurrents.",[17,8260,8261,8264],{},[221,8262,8263],{},"Vous travaillez sans connexion internet."," Trikker a besoin d'une connexion pour l'activation et revérifie la licence de temps à autre, mais fonctionne hors ligne un certain temps entre-temps. PlanElec fonctionne dans le navigateur et nécessite une connexion. Sur des chantiers sans couverture réseau, c'est déterminant.",[17,8266,8267,8270],{},[221,8268,8269],{},"Vous recevez vos plans uniquement en DWG."," PlanElec lit le DXF, Trikker lit en plus le DWG. Si les plans de l'architecte arrivent systématiquement en DWG et que leur auteur ne peut pas fournir de DXF, Trikker vous épargne cette conversion.",[17,8272,8273,8276],{},[221,8274,8275],{},"Vous avez une méthode de travail rodée."," Quinze ans d'historique produit signifient une bibliothèque de symboles aboutie, une communauté d'utilisateurs active et des organismes de contrôle habitués à ces schémas. Changer une méthode en place demande du temps, et cet effort doit se justifier.",[17,8278,8279,8282],{},[221,8280,8281],{},"Vous ne voulez pas d'un produit en Early Access."," PlanElec est récent. Cela implique une base d'utilisateurs plus réduite et des fonctions encore en développement. Qui n'a pas cette marge de manœuvre choisira mieux un produit établi.",[12,8284,8286],{"id":8285},"ce-quil-faut-savoir-avant-de-changer","Ce qu'il faut savoir avant de changer",[5686,8288,8290],{"id":8289},"vos-schémas-existants-ne-suivent-pas","Vos schémas existants ne suivent pas",[17,8292,8293],{},"PlanElec ne peut pas lire les fichiers Trikker. La voie praticable pour changer : terminer les dossiers en cours dans Trikker et démarrer avec PlanElec au prochain nouveau projet. Redessiner intégralement une installation existante est possible, mais représente le temps d'un établissement normal.",[5686,8295,8297],{"id":8296},"ce-que-fait-lautocontrôle-et-ce-quil-ne-fait-pas","Ce que fait l'autocontrôle — et ce qu'il ne fait pas",[17,8299,8300,8301,8304],{},"L'autocontrôle RGIE de PlanElec est une aide à la conception. Il signale des points d'attention pris en charge, par exemple pour les dispositifs de protection et les sections de câbles, et indique les données manquantes. Il ne constitue ",[221,8302,8303],{},"pas un contrôle de conformité officiel"," et ne remplace pas la réception par un organisme agréé. Le rapport précise lui-même quels contrôles sont pris en charge et lesquels ne le sont pas — lisez-le avant de vous y fier.",[5686,8306,8308],{"id":8307},"ce-quun-organisme-de-contrôle-attend-du-document","Ce qu'un organisme de contrôle attend du document",[17,8310,8311],{},"Aucun logiciel de dessin, Trikker compris, ne rend un schéma automatiquement conforme. Ce qui compte, c'est que la documentation soit lisible, complète et conforme à la norme, et qu'elle corresponde à l'installation réelle. Les deux programmes produisent un PDF qui peut y répondre ; l'exactitude du contenu reste la responsabilité de l'auteur.",[5686,8313,8315],{"id":8314},"ce-que-signifie-concrètement-early-access","Ce que signifie concrètement « Early Access »",[17,8317,8318],{},"PlanElec est actuellement gratuit et aucun traitement de paiement n'est actif. Nous n'annonçons pas de prix futur aujourd'hui, parce que nous ne l'avons pas encore fixé. Ce que nous garantissons : vous exportez à tout moment votre schéma unifilaire et votre plan de situation en PDF. Ces documents restent exploitables, y compris indépendamment de l'application.",[12,8320,7801],{"id":7800},[17,8322,8323,8326],{},[221,8324,8325],{},"Combien coûte Trikker en 2026 ?","\n45 € par mois HTVA (54,45 € TVAC pour les particuliers) ou 360 € par an HTVA (435,60 € TVAC). Les deux licences se renouvellent automatiquement et sont résiliables via le portail client. Une licence gratuite avec filigrane existe pour l'enseignement. vérifié le 29 août 2026.",[17,8328,8329,8332],{},[221,8330,8331],{},"Existe-t-il une alternative gratuite à Trikker ?","\nTrikker propose lui-même une version de démonstration gratuite, limitée à cinq circuits et une page de plan de situation, avec filigrane — utilisable pour essayer, pas pour des plans officiels. PlanElec est actuellement gratuit pendant l'Early Access, avec toutes les fonctions, export PDF compris.",[17,8334,8335,8338],{},[221,8336,8337],{},"Trikker fonctionne-t-il sur Mac ?","\nPas aujourd'hui. Trikker fonctionne sous Windows ; une version macOS est annoncée pour la fin de l'été 2026 et une version web devrait suivre. PlanElec fonctionne déjà dans le navigateur sous macOS, Windows, Linux et sur iPad.",[17,8340,8341,8344],{},[221,8342,8343],{},"Puis-je importer mes schémas Trikker dans PlanElec ?","\nNon. Il n'existe pas d'import de fichiers Trikker. Qui change termine ses dossiers en cours dans Trikker et démarre avec PlanElec au projet suivant.",[17,8346,8347,8350],{},[221,8348,8349],{},"Puis-je utiliser le plan de mon architecte ?","\nOui. Chargez le plan au format DXF : PlanElec le place en arrière-plan de votre plan. Si le fichier porte une unité, PlanElec en reprend l'échelle. À défaut — cas fréquent, car les coordonnées DXF sont en soi sans unité — PlanElec propose une unité d'après les dimensions du bâtiment et vous demande de la confirmer. Dans les deux cas, ni redessin ni mesure de votre part. PlanElec ne lit pas le DWG : demandez alors un export DXF, que tout logiciel de CAO produit en quelques secondes. Un PDF convient également : si une planche porte plusieurs niveaux, vous marquez un extrait par niveau à l'import et chacun devient un plan distinct. Le fichier source reste dans le projet, ce qui permet de tirer un extrait supplémentaire plus tard sans nouveau téléversement.",[17,8352,8353,8356],{},[221,8354,8355],{},"Un organisme de contrôle accepte-t-il un schéma issu de PlanElec ?","\nUn contrôleur apprécie si la documentation est lisible, complète et conforme à la norme et si elle correspond à l'installation — pas avec quel programme elle a été réalisée. PlanElec exporte schéma unifilaire et plan de situation en PDF avec des symboles normalisés. L'exactitude du contenu reste du ressort de l'auteur.",[12,8358,5389],{"id":5388},[711,8360,8361,8366,8372,8377],{},[714,8362,8363],{},[203,8364,8365],{"href":3283},"Réaliser un schéma unifilaire : le guide complet",[714,8367,8368],{},[203,8369,8371],{"href":8370},"\u002Ffr\u002Fblog\u002Fplan-de-situation","Qu'est-ce qu'un plan de situation ?",[714,8373,8374],{},[203,8375,8376],{"href":567},"Planifier un tableau électrique : structure et répartition",[714,8378,8379],{},[203,8380,8382],{"href":8381},"\u002Ffr\u002Fblog\u002Fpremiers-pas-planelec","Premiers pas avec PlanElec",[12,8384,8386],{"id":8385},"essayer-par-vous-même","Essayer par vous-même",[17,8388,6951,8389,8391,8392],{},[221,8390,5823],{},", vous concevez plan, circuits et tableau au sein d'un même projet et exportez schéma unifilaire et plan de situation en PDF. Pendant l'Early Access, c'est actuellement gratuit, sans installation. L'autocontrôle accompagne la préparation et ne remplace pas un contrôle officiel. ",[203,8393,7862],{"href":8394,"rel":8395},"https:\u002F\u002Fplanelec.be",[5373],{"title":1212,"searchDepth":1213,"depth":1213,"links":8397},[8398,8399,8400,8401,8402,8408,8409,8410],{"id":7948,"depth":1213,"text":7949},{"id":8198,"depth":1213,"text":8199},{"id":8229,"depth":1213,"text":8230},{"id":8254,"depth":1213,"text":8255},{"id":8285,"depth":1213,"text":8286,"children":8403},[8404,8405,8406,8407],{"id":8289,"depth":5848,"text":8290},{"id":8296,"depth":5848,"text":8297},{"id":8307,"depth":5848,"text":8308},{"id":8314,"depth":5848,"text":8315},{"id":7800,"depth":1213,"text":7801},{"id":5388,"depth":1213,"text":5389},{"id":8385,"depth":1213,"text":8386},"comparison","2026-08-22","Un comparatif factuel de PlanElec et Trikker : plateforme, prix, méthode de travail et aide au RGIE — y compris les cas où Trikker reste le meilleur choix.",{},"\u002Fblog\u002Falternative-trikker.fr","8 min",{"title":7936,"description":8413},"alternative-trikker","blog\u002Falternative-trikker.fr",[7963,5823,8421,1248,8422,8423,1242],"comparatif","plan de situation","logiciel","amEPA4dzbaj_ii3CfavQhyMWCJg1Drn2JDTqaWSpDfc",{"id":8426,"title":8427,"articleId":8428,"body":8429,"category":1228,"date":8821,"description":8822,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":8823,"navigation":1234,"path":8824,"publishDate":8821,"readTime":7919,"refreshInterval":1237,"seo":8825,"slug":8826,"stem":8827,"tags":8828,"__hash__":8833},"blog\u002Fblog\u002Fvoltage-drop-cable-sizing.fr.md","Calculer la chute de tension : quelle longueur de câble ?","voltage-drop-cable-sizing",{"type":9,"value":8430,"toc":8800},[8431,8434,8438,8441,8444,8448,8458,8464,8468,8478,8498,8511,8515,8518,8597,8600,8607,8611,8615,8618,8623,8634,8638,8641,8646,8653,8657,8664,8671,8675,8678,8680,8712,8714,8718,8721,8725,8728,8732,8735,8739,8746,8750,8772,8776,8779,8786,8789,8792],[17,8432,8433],{},"Associer une section au disjoncteur est indispensable, mais ce n’est que le début du dimensionnement. Plus la canalisation est longue et le courant élevé, plus la tension disponible diminue au récepteur. Une section suffisante près du tableau peut donc devenir inadéquate pour un garage, une annexe ou une borne de recharge. Il faut répondre à deux questions distinctes : la protection est-elle compatible avec le conducteur, et la chute de tension reste-t-elle maîtrisée ? Le résultat le plus contraignant fixe la section provisoire.",[12,8435,8437],{"id":8436},"dans-quels-cas-faut-il-y-penser","Dans quels cas faut-il y penser ?",[17,8439,8440],{},"La chute de tension devient surtout visible sur les longues liaisons : abri de jardin, éclairage extérieur, tableau secondaire, pompe à chaleur ou borne de recharge. Elle dépend cependant de bien plus que la distance. Le courant, le réseau mono- ou triphasé, le cuivre ou l’aluminium, la section, la tension nominale et le facteur de puissance interviennent tous.",[17,8442,8443],{},"Il faut aussi raisonner sur le trajet électrique complet depuis le tableau. Calculer uniquement les derniers mètres jusqu’à l’appareil sous-estime le total lorsque plusieurs tronçons se succèdent.",[12,8445,8447],{"id":8446},"ce-que-dit-le-rgie-et-ce-quil-ne-dit-pas","Ce que dit le RGIE — et ce qu’il ne dit pas",[17,8449,8450,8451,207,8454,8457],{},"Le Livre 1 du RGIE, sous-section 5.2.5, ne donne pas de pourcentage numérique. Il impose de limiter la chute de tension aux valeurs décrites dans les règles de l’art. Les seuils couramment employés de ",[221,8452,8453],{},"3 % pour l’éclairage",[221,8455,8456],{},"5 % pour les autres circuits terminaux"," proviennent de l’application usuelle d’IEC\u002FNBN HD 60364-5-52 ; ce ne sont pas des chiffres écrits tels quels dans le RGIE.",[17,8459,8460,8461,212],{},"La section 5.2.1.2 demande en outre que le choix de la canalisation permette le fonctionnement sûr des appareils alimentés. Le tableau 4.11 de 4.4.1.4 limite, pour les installations domestiques, le calibre du dispositif de protection selon la section. Il ne démontre pas à lui seul la capacité de transport du câble dans toutes les conditions de pose. Le tableau 4.11 complet — avec les colonnes fusible et disjoncteur — figure dans ",[203,8462,8463],{"href":1579},"notre tableau section de câble et disjoncteur",[12,8465,8467],{"id":8466},"la-formule-utilisée","La formule utilisée",[17,8469,8470,8471,8474,8475,1096],{},"En prenant ",[4068,8472,8473],{},"L"," comme longueur ",[221,8476,8477],{},"aller simple",[711,8479,8480,8486,8492],{},[714,8481,8482,8483],{},"monophasé : ",[4068,8484,8485],{},"ΔU = 2 × ρ × L × I × cos φ \u002F S",[714,8487,8488,8489],{},"triphasé : ",[4068,8490,8491],{},"ΔU = √3 × ρ × L × I × cos φ \u002F S",[714,8493,8494,8495],{},"pourcentage : ",[4068,8496,8497],{},"ΔU% = ΔU \u002F Un × 100",[17,8499,8500,8503,8504,8506,8507,8510],{},[4068,8501,8502],{},"ρ"," représente la résistivité du conducteur, ",[4068,8505,3547],{}," le courant et ",[4068,8508,8509],{},"S"," la section en mm². Pour ce prédimensionnement, PlanElec utilise 0,0175 Ω·mm²\u002Fm pour le cuivre, 0,029 pour l’aluminium, cos φ 0,95 par défaut, ainsi que la tension nominale du circuit : 230 V pour les circuits terminaux monophasés et, pour les circuits triphasés, la tension entre conducteurs de phase (230 V ou 400 V). C’est un modèle résistif : la réactance et les corrections thermiques ne sont pas incluses.",[12,8512,8514],{"id":8513},"quelle-tension-sapplique-à-votre-circuit","Quelle tension s’applique à votre circuit ?",[17,8516,8517],{},"L’erreur de raisonnement la plus fréquente en matière de chute de tension consiste à confondre la forme du réseau et le circuit. Les 400 V d’un raccordement triphasé ne se mesurent qu’entre deux conducteurs de phase. Un circuit de prises ou d’éclairage ordinaire se raccorde, même dans une telle habitation, entre un conducteur de phase et le neutre : il voit 230 V.",[21,8519,8520,8535],{},[24,8521,8522],{},[27,8523,8524,8527,8529,8532],{},[30,8525,8526],{},"Réseau au raccordement",[30,8528,5870],{},[30,8530,8531],{},"Tension nominale",[30,8533,8534],{},"Facteur",[43,8536,8537,8550,8562,8574,8586],{},[27,8538,8539,8542,8545,8548],{},[48,8540,8541],{},"1×230 V",[48,8543,8544],{},"monophasé",[48,8546,8547],{},"230 V",[48,8549,4515],{},[27,8551,8552,8555,8558,8560],{},[48,8553,8554],{},"3×230 V sans neutre",[48,8556,8557],{},"monophasé, L–L",[48,8559,8547],{},[48,8561,4515],{},[27,8563,8564,8566,8569,8571],{},[48,8565,8554],{},[48,8567,8568],{},"triphasé",[48,8570,8547],{},[48,8572,8573],{},"√3",[27,8575,8576,8579,8582,8584],{},[48,8577,8578],{},"3N~400\u002F230 V",[48,8580,8581],{},"monophasé, L–N",[48,8583,8547],{},[48,8585,4515],{},[27,8587,8588,8590,8592,8595],{},[48,8589,8578],{},[48,8591,8568],{},[48,8593,8594],{},"400 V",[48,8596,8573],{},[17,8598,8599],{},"Comme le facteur et la tension de référence changent ensemble, l’écart est important : les mêmes 16 A sur 30 m avec 2,5 mm² donnent 2,78 % en monophasé, mais 1,38 % pour un circuit triphasé sous 400 V. Calculer par erreur un circuit monophasé comme s’il était triphasé produit un résultat environ deux fois plus favorable et conduit à sous-dimensionner la section.",[17,8601,8602,8603,212],{},"Dans un réseau sans neutre, un circuit monophasé est raccordé entre deux conducteurs de phase. La tension y vaut également 230 V et, comme les deux conducteurs transportent le courant complet, le facteur 2 reste d’application. Pour identifier votre forme de réseau, consultez ",[203,8604,8606],{"href":8605},"\u002Ffr\u002Fblog\u002Fmonophase-triphase-belgique","Monophasé ou triphasé en Belgique",[12,8608,8610],{"id":8609},"deux-exemples-concrets","Deux exemples concrets",[5686,8612,8614],{"id":8613},"éclairage-dun-abri-de-jardin","Éclairage d’un abri de jardin",[17,8616,8617],{},"Prenons 45 m de câble en cuivre, 230 V monophasé, 8 A et 1,5 mm². Avec cos φ 0,95 :",[17,8619,8620],{},[4068,8621,8622],{},"ΔU = 2 × 0,0175 × 45 × 8 × 0,95 \u002F 1,5 = 7,98 V",[17,8624,8625,8626,8629,8630,8633],{},"La perte vaut ",[221,8627,8628],{},"3,47 %",", donc plus que la valeur de 3 % utilisée pour l’éclairage. En passant à 2,5 mm², elle tombe à ",[221,8631,8632],{},"4,79 V, soit 2,08 %",". Cette section est la première taille standard qui satisfait ce critère dans le prédimensionnement.",[5686,8635,8637],{"id":8636},"circuit-de-prises-dans-un-garage","Circuit de prises dans un garage",[17,8639,8640],{},"Pour une liaison cuivre de 30 m, 230 V, 16 A et 2,5 mm² :",[17,8642,8643],{},[4068,8644,8645],{},"ΔU = 2 × 0,0175 × 30 × 16 × 0,95 \u002F 2,5 = 6,38 V",[17,8647,8648,8649,8652],{},"La chute atteint ",[221,8650,8651],{},"2,78 %",". Le calcul préliminaire emploie 5 % pour ce type de circuit : 2,5 mm² convient donc du point de vue de la chute de tension. Cela ne prouve pas encore que le câble est suffisamment chargé dans son mode de pose réel.",[12,8654,8656],{"id":8655},"utiliser-le-calculateur-gratuit","Utiliser le calculateur gratuit",[17,8658,1530,8659,8663],{},[203,8660,8662],{"href":8661},"\u002Ffr\u002Ftools\u002Fcalcul-section-cable","calculateur de chute de tension et de section"," contrôle une section choisie ou cherche une taille provisoire. Il couvre les trois formes de réseau (1×230 V, 3×230 V et 3N~400\u002F230 V) et distingue circuits monophasés et triphasés, avec une charge exprimée en A, W, kW ou kVA, ainsi que des conducteurs en cuivre ou en aluminium. Il compare les sections normalisées et distingue le contrôle de la protection de celui de la chute de tension.",[17,8665,8666,8667,8670],{},"Le calcul s’exécute directement dans le navigateur, pour que les curseurs et le résultat évoluent sans délai ; le même noyau de calcul est aussi disponible via l’API PlanElec. Ce résultat reste un ",[221,8668,8669],{},"prédimensionnement",". L’outil ne vérifie ni le mode de pose, ni le groupement, la température, l’isolant, la réactance, le courant admissible, la tenue au court-circuit, les conditions de coupure, les bornes ou les données fabricant. Une personne compétente doit valider le choix définitif.",[12,8672,8674],{"id":8673},"que-faire-si-la-chute-est-trop-élevée","Que faire si la chute est trop élevée ?",[17,8676,8677],{},"La première solution consiste souvent à augmenter la section. On peut aussi raccourcir le tracé ou installer un tableau secondaire plus près des charges. L’aluminium peut être intéressant sur une longue alimentation, à condition de prévoir les connexions et le dimensionnement adaptés. Pour une borne ou une pompe à chaleur, une alimentation triphasée réduit fortement le courant par phase à puissance totale identique. Une gestion dynamique de la charge peut enfin éviter de dépasser la puissance disponible.",[12,8679,5266],{"id":5265},[711,8681,8682,8688,8694,8700,8706],{},[714,8683,8684,8687],{},[221,8685,8686],{},"Appliquer 3 % à tous les circuits."," Le calcul préliminaire utilise 3 % pour l’éclairage et 5 % pour les autres circuits.",[714,8689,8690,8693],{},[221,8691,8692],{},"S’arrêter au tableau disjoncteur-section."," Il ne tient pas compte de la longueur ni de la charge réelle.",[714,8695,8696,8699],{},[221,8697,8698],{},"Encoder l’aller-retour."," Il faut saisir la distance simple ; la formule monophasée contient déjà le facteur 2.",[714,8701,8702,8705],{},[221,8703,8704],{},"Oublier les tronçons en amont."," Les chutes successives s’additionnent.",[714,8707,8708,8711],{},[221,8709,8710],{},"Présenter le résultat comme une preuve de conformité."," Les conditions de pose et de court-circuit manquent encore.",[12,8713,7801],{"id":7800},[5686,8715,8717],{"id":8716},"faut-il-indiquer-la-longueur-simple-ou-laller-retour","Faut-il indiquer la longueur simple ou l’aller-retour ?",[17,8719,8720],{},"Indiquez la distance simple entre le tableau et la charge. Le facteur 2 couvre le conducteur de retour en monophasé ; le calcul triphasé utilise √3.",[5686,8722,8724],{"id":8723},"une-section-de-15-mm-est-elle-permise-pour-léclairage","Une section de 1,5 mm² est-elle permise pour l’éclairage ?",[17,8726,8727],{},"Le RGIE 5.2.1.2 autorise 1,5 mm² pour un circuit terminal sans prise, si la protection et les autres conditions conviennent. Une grande longueur peut malgré tout imposer 2,5 mm² ou davantage.",[5686,8729,8731],{"id":8730},"une-section-plus-grande-est-elle-toujours-préférable","Une section plus grande est-elle toujours préférable ?",[17,8733,8734],{},"Elle réduit les pertes, mais augmente le coût, l’encombrement et les contraintes de raccordement. Le bon choix est la première section qui réussit toutes les vérifications pertinentes.",[5686,8736,8738],{"id":8737},"le-résultat-suffit-il-pour-le-contrôle-électrique","Le résultat suffit-il pour le contrôle électrique ?",[17,8740,8741,8742,8745],{},"Non. Il s’agit d’un contrôle de plausibilité, pas d’une note de calcul complète. Le ",[203,8743,8744],{"href":6216},"dossier du contrôle électrique"," comprend aussi les schémas, protections, liaisons équipotentielles et autres exigences.",[12,8747,8749],{"id":8748},"articles-associés","Articles associés",[711,8751,8752,8757,8761,8767],{},[714,8753,8754],{},[203,8755,8756],{"href":1579},"Section de câble selon le disjoncteur",[714,8758,8759],{},[203,8760,8606],{"href":8605},[714,8762,8763],{},[203,8764,8766],{"href":8765},"\u002Ffr\u002Fblog\u002Fborne-recharge-rgie","Installer une borne de recharge selon le RGIE",[714,8768,8769],{},[203,8770,8771],{"href":562},"Circuits dédiés pour les appareils",[12,8773,8775],{"id":8774},"transformer-le-pré-calcul-en-note-de-dimensionnement-vérifiable","Transformer le pré-calcul en note de dimensionnement vérifiable",[17,8777,8778],{},"Une feuille utile conserve davantage que le pourcentage final. Identifiez le tableau et le circuit, chaque tronçon, la longueur aller simple, le matériau, le raccordement des phases, la tension nominale, le courant de calcul et l'origine de ce courant. Précisez si la charge vient de la plaque signalétique, d'une étude fabricant ou d'un scénario explicitement posé. Un facteur de puissance supposé doit rester visible et ne pas être présenté comme une mesure.",[17,8780,8781,8782,8785],{},"Consignez ensuite le critère d'acceptation et sa source. La sous-section 5.2.5 du RGIE renvoie aux règles de l'art sans imprimer un pourcentage universel pour toute installation. La valeur de projet peut venir de la norme applicable, d'un cahier des charges, du gestionnaire de réseau ou des limites de l'équipement. Les valeurs de 3 % et 5 % utilisées dans les exemples ci-dessus sont des ",[221,8783,8784],{},"scénarios préliminaires modifiables",", pas une garantie RGIE. Un récepteur sensible peut imposer une plage plus étroite à ses bornes.",[17,8787,8788],{},"Séparez enfin les contrôles. La variation de tension ne répond qu'à une question. Le conducteur doit aussi supporter le courant selon le mode de pose réel, être coordonné avec la protection contre surcharge et court-circuit, respecter la coupure automatique et la tenue thermique, et convenir aux bornes et contraintes mécaniques. Plusieurs tronçons acceptables isolément peuvent donner une chute cumulée excessive. L'alimentation principale, le départ vers le tableau secondaire et le circuit final doivent donc être additionnés.",[17,8790,8791],{},"Après exécution, confrontez le trajet et le conducteur documentés au chantier. Les mesures peuvent révéler des conditions de réseau ou des connexions absentes d'un modèle purement résistif. Mettez à jour schéma unifilaire et liste de câbles si le tracé, le matériau ou la phase change. Cette trace est plus utile qu'une capture affichant seulement un résultat vert.",[17,8793,8794,8795,8799],{},"Base officielle : ",[203,8796,8798],{"href":5371,"rel":8797},[5373],"SPF Économie, Livre 1 V06 du RGIE",", sections 3.2.2 et 5.2.5. Le calculateur PlanElec reste un outil de comparaison préliminaire et ne conclut pas à la conformité.",{"title":1212,"searchDepth":1213,"depth":1213,"links":8801},[8802,8803,8804,8805,8806,8810,8811,8812,8813,8819,8820],{"id":8436,"depth":1213,"text":8437},{"id":8446,"depth":1213,"text":8447},{"id":8466,"depth":1213,"text":8467},{"id":8513,"depth":1213,"text":8514},{"id":8609,"depth":1213,"text":8610,"children":8807},[8808,8809],{"id":8613,"depth":5848,"text":8614},{"id":8636,"depth":5848,"text":8637},{"id":8655,"depth":1213,"text":8656},{"id":8673,"depth":1213,"text":8674},{"id":5265,"depth":1213,"text":5266},{"id":7800,"depth":1213,"text":7801,"children":8814},[8815,8816,8817,8818],{"id":8716,"depth":5848,"text":8717},{"id":8723,"depth":5848,"text":8724},{"id":8730,"depth":5848,"text":8731},{"id":8737,"depth":5848,"text":8738},{"id":8748,"depth":1213,"text":8749},{"id":8774,"depth":1213,"text":8775},"2026-08-02","Calculez la chute de tension de votre câble et voyez quand une section plus grande s'impose. Outil gratuit pour la Belgique, sans inscription.",{},"\u002Fblog\u002Fvoltage-drop-cable-sizing.fr",{"title":8427,"description":8822},"chute-de-tension-section-cable","blog\u002Fvoltage-drop-cable-sizing.fr",[8829,8830,8831,8832],"chute-de-tension","section-cable","calculateur","rgie","vDIznDLkl8QiGCqUYrBc1dNxFzrUoqyqjCbbLwU_JHw",{"id":8835,"title":8836,"articleId":8837,"body":8838,"category":1228,"date":9272,"description":9273,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":9274,"navigation":1234,"path":9275,"publishDate":9272,"readTime":1994,"refreshInterval":1237,"seo":9276,"slug":9277,"stem":9278,"tags":9279,"__hash__":9285},"blog\u002Fblog\u002Fsingle-phase-vs-three-phase.fr.md","Monophasé ou triphasé ? Réseau et raccordement en Belgique","single-phase-vs-three-phase",{"type":9,"value":8839,"toc":9252},[8840,8844,8847,8861,8872,8876,8947,8950,8954,8957,8996,8999,9003,9023,9032,9036,9039,9043,9046,9050,9053,9057,9060,9064,9067,9070,9074,9077,9080,9084,9087,9090,9094,9132,9136,9142,9148,9154,9158,9161,9164,9168,9171,9174,9178,9181,9185,9228,9230,9247],[12,8841,8843],{"id":8842},"réponse-courte-il-nexiste-pas-seulement-deux-cas","Réponse courte : il n'existe pas seulement deux cas",[17,8845,8846],{},"En Belgique, il faut distinguer deux questions :",[5034,8848,8849,8855],{},[714,8850,8851,8854],{},[221,8852,8853],{},"Le réseau basse tension dans la rue :"," 230 V sans neutre ou 400\u002F230 V avec neutre.",[714,8856,8857,8860],{},[221,8858,8859],{},"Le raccordement individuel du bâtiment :"," monophasé ou triphasé.",[17,8862,8863,8864,8867,8868,8871],{},"« Monophasé = 1×230 V » décrit donc un raccordement, pas une forme distincte du réseau de rue. Le 230 V monophasé peut être fourni ",[221,8865,8866],{},"phase–neutre"," depuis un réseau 400\u002F230 V ou ",[221,8869,8870],{},"phase–phase"," depuis un réseau 3×230 V. ORES précise qu'un raccordement monophasé ne comporte pas systématiquement un neutre.",[12,8873,8875],{"id":8874},"les-quatre-combinaisons","Les quatre combinaisons",[21,8877,8878,8894],{},[24,8879,8880],{},[27,8881,8882,8885,8888,8891],{},[30,8883,8884],{},"Réseau de rue",[30,8886,8887],{},"Raccordement du bâtiment",[30,8889,8890],{},"Conducteurs au raccordement",[30,8892,8893],{},"Notation technique",[43,8895,8896,8910,8922,8935],{},[27,8897,8898,8901,8904,8907],{},[48,8899,8900],{},"400\u002F230 V avec N",[48,8902,8903],{},"Monophasé",[48,8905,8906],{},"L + N",[48,8908,8909],{},"1×230 V, L–N",[27,8911,8912,8914,8917,8920],{},[48,8913,8900],{},[48,8915,8916],{},"Triphasé",[48,8918,8919],{},"L1 + L2 + L3 + N",[48,8921,8578],{},[27,8923,8924,8927,8929,8932],{},[48,8925,8926],{},"230 V sans N",[48,8928,8903],{},[48,8930,8931],{},"Deux conducteurs de phase",[48,8933,8934],{},"1×230 V, L–L",[27,8936,8937,8939,8941,8944],{},[48,8938,8926],{},[48,8940,8916],{},[48,8942,8943],{},"Trois conducteurs de phase",[48,8945,8946],{},"3×230 V sans N",[17,8948,8949],{},"Le réseau 3×230 V n'est pas anecdotique. Fluvius comptait encore 18 101 km de réseau basse tension 230 V fin 2024, surtout dans les zones urbaines et occidentales. Sibelga indique qu'environ 80 % de Bruxelles est couvert en 230 V. Cela ne signifie pas que chaque logement y est triphasé : Sibelga présente 9,2 kVA, en monophasé 230 V à 40 A, comme raccordement domestique standard.",[12,8951,8953],{"id":8952},"puissance-avec-le-même-calibre","Puissance avec le même calibre",[17,8955,8956],{},"ORES publie les valeurs suivantes à 40 A :",[21,8958,8959,8970],{},[24,8960,8961],{},[27,8962,8963,8966],{},[30,8964,8965],{},"Raccordement",[30,8967,8969],{"align":8968},"right","Puissance apparente à 40 A",[43,8971,8972,8980,8988],{},[27,8973,8974,8977],{},[48,8975,8976],{},"Monophasé 230 V",[48,8978,8979],{"align":8968},"9,2 kVA",[27,8981,8982,8985],{},[48,8983,8984],{},"Triphasé 3×230 V",[48,8986,8987],{"align":8968},"15,9 kVA",[27,8989,8990,8993],{},[48,8991,8992],{},"Triphasé 3N~400\u002F230 V",[48,8994,8995],{"align":8968},"27,7 kVA",[17,8997,8998],{},"La capacité réelle dépend toujours du disjoncteur de raccordement et des données du gestionnaire de réseau.",[12,9000,9002],{"id":9001},"borne-pompe-à-chaleur-et-photovoltaïque","Borne, pompe à chaleur et photovoltaïque",[711,9004,9005,9011,9017],{},[714,9006,9007,9010],{},[221,9008,9009],{},"Borne de recharge :"," 3,7 ou 7,4 kW peuvent être possibles en monophasé. Pour 11 ou 22 kW, il faut normalement un raccordement triphasé adapté. Tous les appareils ne fonctionnent pas en 3×230 V ; Sibelga signale des restrictions pour la recharge à 11\u002F22 kW.",[714,9012,9013,9016],{},[221,9014,9015],{},"Pompe à chaleur et taque de cuisson :"," vérifiez la plaque signalétique. Un appareil prévu pour 3N~400 V ne fonctionne pas automatiquement sur 3×230 V sans neutre.",[714,9018,9019,9022],{},[221,9020,9021],{},"Photovoltaïque :"," la puissance d'onduleur admise et la répartition des phases dépendent du gestionnaire et du raccordement réel. Une limite belge générale de 5 kWc serait trompeuse.",[17,9024,9025,9026,207,9029,212],{},"Avant un achat important, vérifiez donc à la fois ",[221,9027,9028],{},"mono\u002Ftriphasé",[221,9030,9031],{},"230 V sans N\u002F400-230 V avec N",[12,9033,9035],{"id":9034},"différentiel-sur-un-réseau-3230-v","Différentiel sur un réseau 3×230 V",[17,9037,9038],{},"Un dispositif différentiel n'a pas besoin du neutre comme « référence ». Il compare les courants dans tous les conducteurs actifs qui le traversent. En 3×230 V, les conducteurs de phase concernés doivent donc être mesurés et coupés ensemble. L'ancienne affirmation générale selon laquelle l'absence de neutre réduirait la protection différentielle était incorrecte.",[12,9040,9042],{"id":9041},"équilibrage-des-phases","Équilibrage des phases",[17,9044,9045],{},"Une répartition raisonnable des charges est une bonne pratique pour un raccordement triphasé. Le RGIE ne fixe toutefois pas une limite générale exacte de 30 %. Un tel seuil peut servir d'alerte de planification, mais ne doit pas être présenté comme une citation réglementaire. En monophasé, il n'y a pas trois phases à équilibrer.",[12,9047,9049],{"id":9048},"identifier-votre-raccordement","Identifier votre raccordement",[17,9051,9052],{},"Vérifiez le compteur, le disjoncteur de raccordement et les conducteurs entrants sans ouvrir les parties plombées. ORES illustre le monophasé 230 V, le 3×230 V et le 3×400 V + N. En cas de doute, le gestionnaire ou un électricien peut confirmer le raccordement. Le simple comptage des fils visibles peut être trompeur à cause du PE, du câblage interne ou d'une ancienne installation.",[12,9054,9056],{"id":9055},"renforcement-ou-modification","Renforcement ou modification",[17,9058,9059],{},"Il n'existe ni prix ni délai belge unique. Ils dépendent du gestionnaire, de la puissance demandée, du réseau disponible dans la rue, de l'emplacement du compteur et des adaptations intérieures. Demandez d'abord une offre concrète au gestionnaire compétent. Une modification importante peut aussi imposer des schémas mis à jour et un nouveau contrôle.",[12,9061,9063],{"id":9062},"transformer-les-plaques-signalétiques-en-décision-de-raccordement","Transformer les plaques signalétiques en décision de raccordement",[17,9065,9066],{},"Établissez un bilan des charges avant de demander davantage de puissance. Séparez les consommations continues, les pointes simultanées et les appareils pilotables. Taque, pompe à chaleur, chauffe-eau instantané, borne et onduleur ont des profils différents. Additionner toutes les plaques ne donne pas automatiquement la puissance de raccordement, mais écarter les gros appareils sans calcul serait tout aussi trompeur. Le pilotage réduit les pointes uniquement s'il est compatible avec les appareils, le compteur et la procédure du gestionnaire.",[17,9068,9069],{},"Pour chaque équipement, notez tension admise, besoin du neutre, nombre de phases et courant maximal par phase. Ajoutez courant de démarrage, facteur de puissance et conditions fabricant lorsqu'ils comptent. Le mot « triphasé » ne suffit pas : un appareil 3N~400 V peut exiger un neutre ou un couplage différent d'un modèle 3×230 V. L'électricien vérifie aussi protections, sections, conditions de coupure et éventuellement l'ordre des phases.",[12,9071,9073],{"id":9072},"comprendre-les-valeurs-en-kva","Comprendre les valeurs en kVA",[17,9075,9076],{},"En 230 V monophasé, la puissance apparente vaut approximativement tension multipliée par courant. Pour une charge triphasée équilibrée, on multiplie encore par √3 en utilisant la tension entre phases correcte. ORES affiche ainsi, à 40 A, environ 9,2 kVA en monophasé, 15,9 kVA en 3×230 V et 27,7 kVA en 3×400 V + N. Ces chiffres donnent un ordre technique, pas automatiquement la puissance active de chaque appareil, le foisonnement, le contrat ou l'accord du réseau.",[17,9078,9079],{},"En présence de déséquilibre, chaque conducteur de phase doit être examiné. Une grande capacité totale n'empêche pas la surcharge d'une phase chargée par trop d'appareils monophasés. Documentez l'affectation dans le tableau et revoyez-la après modification. Une alerte logicielle peut aider, mais un pourcentage arbitraire ne remplace pas le calcul et les conditions de raccordement.",[12,9081,9083],{"id":9082},"représenter-correctement-lalimentation","Représenter correctement l'alimentation",[17,9085,9086],{},"Indiquez tension, nature du courant et configuration au point d'alimentation. Montrez la protection principale et tous les conducteurs actifs. N'inventez aucun neutre sur un réseau 3×230 V ; en 3N~400\u002F230 V, représentez-le là où il est réellement distribué. Après conversion, contrôlez tableau, protections, câbles et circuits avant de mettre les plans à l'état réalisé.",[17,9088,9089],{},"PlanElec peut séparer réseau, raccordement, affectation de phase et circuits. Il ne connaît pas la disponibilité contraignante du réseau de rue, toutes les données appareil ni l'accord du gestionnaire. Sa sortie ne remplace donc ni demande au gestionnaire, ni étude d'exécution, ni contrôle officiel.",[12,9091,9093],{"id":9092},"erreurs-de-décision-fréquentes","Erreurs de décision fréquentes",[711,9095,9096,9102,9108,9114,9120,9126],{},[714,9097,9098,9101],{},[221,9099,9100],{},"Lire uniquement le compteur :"," l'affichage ne décrit pas toujours toute la configuration.",[714,9103,9104,9107],{},[221,9105,9106],{},"Confondre 3×230 V et 3N~400\u002F230 V :"," les tensions et conducteurs disponibles diffèrent.",[714,9109,9110,9113],{},[221,9111,9112],{},"Confondre kVA et kW :"," la puissance active dépend aussi de la charge et du facteur de puissance.",[714,9115,9116,9119],{},[221,9117,9118],{},"Prendre la puissance de borne pour le besoin total :"," les autres usages simultanés manquent.",[714,9121,9122,9125],{},[221,9123,9124],{},"Conserver les anciens plans après conversion :"," alimentation, protections et phases deviennent faux.",[714,9127,9128,9131],{},[221,9129,9130],{},"Ouvrir un élément plombé :"," utilisez les informations visibles, le gestionnaire ou un professionnel.",[12,9133,9135],{"id":9134},"trois-scénarios-concrets","Trois scénarios concrets",[17,9137,9138,9141],{},[221,9139,9140],{},"Existant 1×230 V :"," confirmez calibre et présence réelle du neutre. Une borne limitée avec pilotage peut être envisageable, mais véhicule, borne, consommation de la maison et conditions du gestionnaire décident. Une puissance publicitaire ne crée pas de capacité disponible.",[17,9143,9144,9147],{},[221,9145,9146],{},"Existant 3×230 V :"," répartissez les charges monophasées entre conducteurs et vérifiez chaque appareil triphasé pour un fonctionnement sans neutre. Le différentiel mesure ensemble les conducteurs actifs concernés. La mention « triphasé » ne suffit pas si l'électronique exige 230 V entre phase et neutre.",[17,9149,9150,9153],{},[221,9151,9152],{},"Existant 3N~400\u002F230 V :"," les charges monophasées utilisent généralement phase-neutre et l'appareil triphasé suit le couplage fabricant. Une capacité totale élevée ne supprime ni la limite par phase ni le dimensionnement des protections et câbles.",[12,9155,9157],{"id":9156},"avant-de-demander-loffre","Avant de demander l'offre",[17,9159,9160],{},"Rassemblez EAN ou référence, réglage actuel, puissance souhaitée, fiches des appareils et date visée. Demandez explicitement tension, phases et neutre disponibles à l'adresse. Faites établir les adaptations du compteur, du câble de liaison, du tableau, des différentiels et de la répartition. Ce n'est qu'ensuite que l'offre réseau et les travaux intérieurs deviennent comparables.",[17,9162,9163],{},"Après conversion, contrôlez tous les câbles, protections et équipements dépendants. Conservez l'ancien plan et publiez une nouvelle version datée correspondant à l'état réalisé.",[12,9165,9167],{"id":9166},"mesure-et-mise-en-service","Mesure et mise en service",[17,9169,9170],{},"La configuration finale ne se déduit pas uniquement des documents. Une personne qualifiée vérifie les tensions réelles avec une méthode appropriée, sans accès non autorisé aux équipements du gestionnaire. Ordre des phases, neutre et conducteur de protection sont contrôlés séparément lorsque nécessaire. Après modification, les essais et mesures requis couvrent les travaux concernés.",[17,9172,9173],{},"Pour les grosses charges pilotées, observez aussi le comportement réel. Le gestionnaire de charge doit adopter un état sûr et documenté en cas de perte de communication ou de mesure erronée. Sa limite correspond à la protection du raccordement et tient compte des pointes par phase, pas seulement d'une moyenne. Toute modification de réglage est enregistrée.",[12,9175,9177],{"id":9176},"décider-avec-plusieurs-critères","Décider avec plusieurs critères",[17,9179,9180],{},"Croisez réseau confirmé, tensions des appareils, pointes par phase, extensions prévues et coût du gestionnaire. Le triphasé n'est pas automatiquement nécessaire ou rentable ; le monophasé n'est pas automatiquement suffisant. La bonne solution répond aux besoins vérifiés et est soutenue par le processus réseau et l'étude électrique.",[12,9182,9184],{"id":9183},"sources","Sources",[711,9186,9187,9194,9201,9208,9215,9222],{},[714,9188,9189],{},[203,9190,9193],{"href":9191,"rel":9192},"https:\u002F\u002Fwww.ores.be\u002Fparticulier\u002Freconnaitre-informations-techniques\u002F",[5373],"ORES : reconnaître les informations techniques",[714,9195,9196],{},[203,9197,9200],{"href":9198,"rel":9199},"https:\u002F\u002Fwww.sibelga.be\u002Ffr\u002Fraccordements-compteurs\u002Fmon-raccordement\u002Fpuissance-electrique",[5373],"Sibelga : puissance électrique et raccordement",[714,9202,9203],{},[203,9204,9207],{"href":9205,"rel":9206},"https:\u002F\u002Fwww.sibelga.be\u002Ffr\u002Fraccordements-compteurs\u002Frecharge-electrique\u002Frecharge-a-domicile",[5373],"Sibelga : recharge à domicile",[714,9209,9210],{},[203,9211,9214],{"href":9212,"rel":9213},"https:\u002F\u002Fover.fluvius.be\u002Fsites\u002Ffluvius\u002Ffiles\u002F2025-06\u002Finvesteringsplan-2026-2035-versie-publieke-consultatie.pdf",[5373],"Fluvius : plan d'investissement 2026–2035",[714,9216,9217],{},[203,9218,9221],{"href":9219,"rel":9220},"https:\u002F\u002Fdownload.schneider-electric.com\u002Ffiles?p_File_Id=905251744&p_File_Name=ECT114.pdf&p_Reference=ECT114&p_enDocType=Cahier+Technique",[5373],"Schneider Electric : principe de fonctionnement des différentiels, y compris les circuits triphasés sans neutre",[714,9223,9224],{},[203,9225,9227],{"href":5371,"rel":9226},[5373],"SPF Économie : publication officielle actuelle du RGIE, Livre 1",[12,9229,8749],{"id":8748},[711,9231,9232,9237,9242],{},[714,9233,9234],{},[203,9235,9236],{"href":1574},"Calculer la chute de tension et choisir la section",[714,9238,9239],{},[203,9240,9241],{"href":8765},"Installer une borne en Belgique",[714,9243,9244],{},[203,9245,9246],{"href":6354},"Déclarer et documenter une installation PV",[17,9248,9249],{},[203,9250,9251],{"href":7861},"Documenter séparément réseau et raccordement dans PlanElec →",{"title":1212,"searchDepth":1213,"depth":1213,"links":9253},[9254,9255,9256,9257,9258,9259,9260,9261,9262,9263,9264,9265,9266,9267,9268,9269,9270,9271],{"id":8842,"depth":1213,"text":8843},{"id":8874,"depth":1213,"text":8875},{"id":8952,"depth":1213,"text":8953},{"id":9001,"depth":1213,"text":9002},{"id":9034,"depth":1213,"text":9035},{"id":9041,"depth":1213,"text":9042},{"id":9048,"depth":1213,"text":9049},{"id":9055,"depth":1213,"text":9056},{"id":9062,"depth":1213,"text":9063},{"id":9072,"depth":1213,"text":9073},{"id":9082,"depth":1213,"text":9083},{"id":9092,"depth":1213,"text":9093},{"id":9134,"depth":1213,"text":9135},{"id":9156,"depth":1213,"text":9157},{"id":9166,"depth":1213,"text":9167},{"id":9176,"depth":1213,"text":9177},{"id":9183,"depth":1213,"text":9184},{"id":8748,"depth":1213,"text":8749},"2026-07-27","1×230 V, 3×230 V ou 3N~400\u002F230 V : distinguez réseau de rue, neutre et nombre de phases du raccordement.",{},"\u002Fblog\u002Fsingle-phase-vs-three-phase.fr",{"title":8836,"description":9273},"monophase-triphase-belgique","blog\u002Fsingle-phase-vs-three-phase.fr",[1243,1242,8544,8568,1249,9280,9281,9282,9283,9284,7928,1248],"Fluvius","ORES","Sibelga","borne de recharge","pompe à chaleur","Eh2cAt4ywXYJrzAVKfaFXACYE5_BSWPMT3fbY3d2pWE",{"id":9287,"title":9288,"articleId":9289,"body":9290,"category":1228,"date":9638,"description":9639,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":9640,"navigation":1234,"path":9641,"publishDate":9638,"readTime":8416,"refreshInterval":7920,"seo":9642,"slug":9643,"stem":9644,"tags":9645,"__hash__":9649},"blog\u002Fblog\u002Fplanelec-capabilities-overview.fr.md","Que peut-on faire avec PlanElec ? Fonctions, automatisation et exports","planelec-capabilities-overview",{"type":9,"value":9291,"toc":9622},[9292,9295,9301,9305,9396,9400,9403,9406,9410,9413,9436,9444,9448,9451,9454,9458,9461,9479,9482,9485,9493,9497,9500,9507,9511,9514,9524,9531,9535,9555,9558,9562,9565,9582,9586,9589,9592,9595,9598,9605,9609,9612,9615,9619],[17,9293,9294],{},"PlanElec réunit le flux belge de planification électrique dans un projet commun : du plan aux récepteurs, câbles, circuits et tableau, puis au schéma unifilaire, au plan de situation et aux différentes sorties PDF. L'outil s'adresse en priorité aux entreprises d'électricité et aux bureaux d'études, tout en restant accessible aux maîtres d'ouvrage et propriétaires motivés.",[17,9296,9297,9298],{},"La réponse courte est la suivante : ",[221,9299,9300],{},"vous modélisez une fois la structure spatiale et électrique, puis vous en déduisez des plans, des listes et un auto-contrôle RGIE pris en charge.",[12,9302,9304],{"id":9303},"le-flux-en-un-coup-dœil","Le flux en un coup d'œil",[21,9306,9307,9319],{},[24,9308,9309],{},[27,9310,9311,9313,9316],{},[30,9312,7447],{},[30,9314,9315],{},"Ce que vous faites dans PlanElec",[30,9317,9318],{},"Résultat",[43,9320,9321,9332,9343,9354,9365,9375,9386],{},[27,9322,9323,9326,9329],{},[48,9324,9325],{},"Projet",[48,9327,9328],{},"Créer le bâtiment, les étages et les métadonnées",[48,9330,9331],{},"Base commune des plans et cartouches",[27,9333,9334,9337,9340],{},[48,9335,9336],{},"Plan",[48,9338,9339],{},"Dessiner les murs et les pièces ou calibrer une image de référence",[48,9341,9342],{},"Modèle spatial",[27,9344,9345,9348,9351],{},[48,9346,9347],{},"Équipements",[48,9349,9350],{},"Placer prises, interrupteurs, luminaires, raccordements fixes et tableaux",[48,9352,9353],{},"Plan de situation et base des récepteurs",[27,9355,9356,9359,9362],{},[48,9357,9358],{},"Topologie",[48,9360,9361],{},"Relier circuits, protections, câbles et dérivations",[48,9363,9364],{},"Modèle électrique",[27,9366,9367,9369,9372],{},[48,9368,50],{},[48,9370,9371],{},"Disposer les modules sur les rails DIN et vérifier les chaînes de protection",[48,9373,9374],{},"Planification modifiable du tableau",[27,9376,9377,9380,9383],{},[48,9378,9379],{},"Schéma et contrôle",[48,9381,9382],{},"Vérifier le schéma unifilaire et lancer l'auto-contrôle pris en charge",[48,9384,9385],{},"Constats et schéma documentable",[27,9387,9388,9390,9393],{},[48,9389,1025],{},[48,9391,9392],{},"Produire des PDF séparés ou un dossier de travail sélectionnable",[48,9394,9395],{},"Documents de projet pour contrôle et coordination",[12,9397,9399],{"id":9398},"créer-le-plan-et-le-plan-de-situation","Créer le plan et le plan de situation",[17,9401,9402],{},"Dans l'éditeur SVG, vous dessinez les murs extérieurs et intérieurs sous forme de polygone, de rectangle ou de segments. Les surfaces fermées deviennent des pièces. Vous pouvez importer un plan existant comme image de référence, le faire pivoter et le calibrer sur une distance connue.",[17,9404,9405],{},"Vous placez ensuite les symboles électriques sur les murs ou librement dans la pièce : prises, interrupteurs, luminaires, raccordements spéciaux, boîtes de connexion et de dérivation, tableaux, entre autres. Les chaînes d'interrupteurs et les chemins de câble restent visibles dans le même modèle spatial. Le plan de situation produit reprend ces positions réelles.",[12,9407,9409],{"id":9408},"préparer-automatiquement-les-étapes-répétitives","Préparer automatiquement les étapes répétitives",[17,9411,9412],{},"PlanElec propose plusieurs automatismes que vous pouvez contrôler séparément :",[711,9414,9415,9418,9421,9424,9427,9430,9433],{},[714,9416,9417],{},"propositions de prises, d'éclairage, d'équipement standard et de grilles de spots ;",[714,9419,9420],{},"liaison automatique des interrupteurs et luminaires libres d'une pièce ;",[714,9422,9423],{},"segments de câble issus des relations topologiques et trajets le long des murs ;",[714,9425,9426],{},"regroupement et affectation automatiques des récepteurs aux circuits ;",[714,9428,9429],{},"traitement séparé des appareils spéciaux pris en charge ;",[714,9431,9432],{},"répartition des phases dans une installation polyphasée ;",[714,9434,9435],{},"placement automatique des protections existantes sur les rails DIN avec réserve de place.",[17,9437,9438,9439,9443],{},"L'automatisation ne constitue pas une étude professionnelle infaillible. Les propositions peuvent être déplacées et réaffectées, et les trajets ou longueurs de câble peuvent être corrigés manuellement. Le guide ",[203,9440,9442],{"href":9441},"\u002Ffr\u002Fhelp\u002Fplanification-automatique","Planification automatique"," décrit le processus en détail.",[12,9445,9447],{"id":9446},"planifier-ensemble-le-tableau-et-le-schéma-unifilaire","Planifier ensemble le tableau et le schéma unifilaire",[17,9449,9450],{},"Dans l'éditeur du tableau, vous disposez l'interrupteur principal, les différentiels, les disjoncteurs et les accessoires pris en charge sur une grille réelle en modules. Les protections peuvent être placées automatiquement, puis déplacées ou reliées manuellement. Pour plusieurs phases, PlanElec affiche les charges modélisées et avertit en cas de déséquilibre marqué.",[17,9452,9453],{},"Le schéma unifilaire est dérivé de la topologie électrique. Les branches de récepteurs, protections, dérivations et données de câble restent ainsi reliées au modèle du projet. Après une modification, le schéma peut être reconstruit à partir de l'état actuel, sans devoir comparer manuellement plusieurs dessins indépendants.",[12,9455,9457],{"id":9456},"quels-documents-peut-on-exporter","Quels documents peut-on exporter ?",[17,9459,9460],{},"Les sorties centrales actuellement disponibles sont :",[711,9462,9463,9469,9474],{},[714,9464,5038,9465,9468],{},[221,9466,9467],{},"schéma unifilaire en PDF multipage"," ;",[714,9470,5038,9471,9468],{},[221,9472,9473],{},"plan de situation en PDF",[714,9475,5038,9476,212],{},[221,9477,9478],{},"rapport indicatif d'auto-contrôle RGIE",[17,9480,9481],{},"Le flux de développement\u002Fpilote ajoute les listes de circuits, de matériel et de câbles. La liste de matériel décompose les contributions modélisées de manière générique et indépendante des fabricants, en affichant ses hypothèses standard. Elle ne contient ni prix ni référence fabricant concrète et ne constitue pas encore une validation de commande.",[17,9483,9484],{},"Le générateur de dossier peut réunir les documents sélectionnés dans un PDF de travail avec page de garde, sommaire et pagination globale. Ce dossier est une sortie locale de pilote et de contrôle, pas encore un snapshot serveur final versionné. Le PDF du tableau n'est disponible que si le feature flag correspondant est actif et si le tableau contient des données.",[17,9486,9487,9488,9492],{},"Consultez ",[203,9489,9491],{"href":9490},"\u002Ffr\u002Fhelp\u002Fexporter-les-documents","Exporter les documents"," pour le statut de chaque sortie et les étapes de téléchargement.",[12,9494,9496],{"id":9495},"que-contrôle-planelec-par-rapport-au-rgie","Que contrôle PlanElec par rapport au RGIE ?",[17,9498,9499],{},"L'auto-contrôle assisté par logiciel couvre une partie documentée des règles évaluables à partir des données enregistrées. Il peut afficher des constats dans les domaines pris en charge et signaler les lacunes de couverture détectées.",[17,9501,9502,9503,9506],{},"Il ne s'agit ",[221,9504,9505],{},"ni d'un certificat de conformité",", ni d'une garantie de réussite au contrôle. Les mesures, conditions sur place, justificatifs de fabricants et domaines réglementaires qui ne sont pas entièrement modélisés restent hors de portée d'un contrôle purement logiciel. Seul un organisme de contrôle agréé rend l'évaluation officielle.",[5686,9508,9510],{"id":9509},"quelle-est-létendue-exacte-de-cette-partie","Quelle est l'étendue exacte de cette partie ?",[17,9512,9513],{},"Un installateur nous a posé la question sans détour : PlanElec couvre-t-il tout le Livre 1, y compris toutes les exceptions, ou seulement les cas les plus courants ? La réponse honnête est la seconde.",[17,9515,1530,9516,9519,9520,9523],{},[221,9517,9518],{},"texte réglementaire intégré"," est complet — Livre 1, Version 06, Parties 1 à 9. La ",[221,9521,9522],{},"logique de contrôle automatique"," n'en couvre qu'une partie : l'accent porte sur la protection, la mise à la terre, le dimensionnement des câbles et la complétude du dossier dans une installation domestique à courant alternatif. Le côté courant continu, onze des quatorze chapitres consacrés aux installations particulières ainsi que les exceptions transitoires des articles 59 et 69 n'en font pas partie.",[17,9525,9526,9527,9530],{},"Nous préférons publier cette limite plutôt que de la laisser découvrir : ",[203,9528,9529],{"href":3175},"la liste complète de ce que l'autocontrôle vérifie et ne vérifie pas"," figure dans la base de connaissances.",[12,9532,9534],{"id":9533},"à-qui-planelec-sadresse-t-il","À qui PlanElec s'adresse-t-il ?",[711,9536,9537,9543,9549],{},[714,9538,4251,9539,9542],{},[221,9540,9541],{},"entreprises d'électricité"," disposent d'un flux continu de la saisie aux plans et aux listes.",[714,9544,4251,9545,9548],{},[221,9546,9547],{},"bureaux d'études"," peuvent modéliser ensemble les relations spatiales et électriques et adapter les variantes de manière traçable.",[714,9550,4251,9551,9554],{},[221,9552,9553],{},"maîtres d'ouvrage et propriétaires motivés"," peuvent structurer un relevé ou une préparation, mais doivent faire valider le résultat par un électricien qualifié avant les travaux.",[17,9556,9557],{},"PlanElec ne remplace ni l'étude professionnelle, ni l'exécution, ni le contrôle officiel.",[12,9559,9561],{"id":9560},"état-actuel-de-learly-access","État actuel de l'Early Access",[17,9563,9564],{},"L'Early Access coûte actuellement 0 EUR et aucun paiement n'est encore actif. Les fonctions pilotes restent accompagnées de leur statut visible. Aucun prix public ni abonnement Pro achetable n'est publié à ce jour.",[17,9566,9567,9568,9572,9573,9577,9578,212],{},"Pour aller plus loin, consultez la ",[203,9569,9571],{"href":9570},"\u002Ffr\u002Ffeatures","vue complète des fonctionnalités",", suivez les guides de la ",[203,9574,9576],{"href":9575},"\u002Ffr\u002Fhelp","base de connaissances"," ou ",[203,9579,9581],{"href":9580},"\u002Fauth\u002Fregister","inscrivez-vous à PlanElec",[12,9583,9585],{"id":9584},"une-méthode-pratique-de-validation","Une méthode pratique de validation",[17,9587,9588],{},"Considérez chaque automatisme comme une proposition avec un réviseur identifié. Fixez d'abord la géométrie et les noms des locaux, puis placez uniquement les appareils réellement prévus. Vérifiez chaînes de commande et boîtes de connexion avant d'affecter les circuits : une erreur de topologie se propage vers les tronçons et le schéma unifilaire. Remplacez les valeurs par défaut par les données réelles des conducteurs et protections.",[17,9590,9591],{},"Au tableau, contrôlez phases, protection amont, groupes différentiels, réserve modulaire et chemins électriques entre appareils. La grille aide à organiser, mais ne connaît ni conditions de défaut mesurées, ni courant de court-circuit présumé, ni mode de pose, ni toutes les contraintes fabricant. Ces décisions restent à l'étude et à l'installation compétentes.",[17,9593,9594],{},"Avant export, lancez l'autocontrôle pris en charge et lisez constats et limites de couverture. Un résultat vert signifie seulement qu'aucun problème n'a été trouvé par les contrôles supportés avec les données fournies ; le Livre 1 n'est pas contrôlé intégralement. Confrontez les deux plans à l'exécution, joignez pièces et mesures requises, puis confiez le contrôle officiel à un organisme agréé.",[17,9596,9597],{},"Le statut des sorties compte aussi. Les PDF du schéma unifilaire et du plan de position sont disponibles dans le parcours normal. La liste de matériel neutre détaillée et le dossier combiné sont des sorties pilotes fonctionnelles : elles signalent données connues, partielles et manquantes, sans constituer une commande prête ni un rapport officiel. Le PDF du tableau dépend de son feature flag. Les bases techniques batterie, groupe et V2G bidirectionnel ne sont pas des parcours complets publiés.",[17,9599,9600,9601,9604],{},"Ce texte a été vérifié le 29 août 2026 par rapport à la ",[203,9602,9603],{"href":9570},"page des fonctionnalités"," et au parcours éditeur\u002Fexport accessible. Les statuts peuvent évoluer ; le libellé visible dans le produit est la référence immédiate. Conservez les versions exportées dans le dossier d'installation.",[12,9606,9608],{"id":9607},"clôturer-un-projet-sans-masquer-les-inconnues","Clôturer un projet sans masquer les inconnues",[17,9610,9611],{},"Vérifiez noms des locaux et appareils, références communes, chaîne de protection, données de canalisation, tableau et position réelle. Une alerte ouverte reçoit une valeur justifiée ou reste une tâche explicite ; elle n'est pas remplie par une hypothèse plausible. Ajoutez hors de PlanElec les notices et mesures exigées par le dossier.",[17,9613,9614],{},"La liste de matériel pilote distingue données connues, partielles et manquantes afin de ne pas inventer câbles PV, connecteurs, réserves ou articles fabricant. Utilisez-la pour revue et coordination, pas comme commande automatique. Avant le contrôle, exportez une version datée, confrontez-la au chantier et archivez la version validée. Après modification, recommencez le rapprochement.",[5686,9616,9618],{"id":9617},"exemple-de-révision","Exemple de révision",[17,9620,9621],{},"Pour ajouter un circuit de lave-vaisselle, partez de l'appareil réel, puis créez connexion, circuit, protection, câble et place au tableau. Régénérez les deux plans depuis le même état et vérifiez la référence commune. Ajoutez notices et mesures au dossier externe. PlanElec aide à garder les vues cohérentes, sans décider du mode de pose, des mesures ni de l'acceptation officielle.",{"title":1212,"searchDepth":1213,"depth":1213,"links":9623},[9624,9625,9626,9627,9628,9629,9632,9633,9634,9635],{"id":9303,"depth":1213,"text":9304},{"id":9398,"depth":1213,"text":9399},{"id":9408,"depth":1213,"text":9409},{"id":9446,"depth":1213,"text":9447},{"id":9456,"depth":1213,"text":9457},{"id":9495,"depth":1213,"text":9496,"children":9630},[9631],{"id":9509,"depth":5848,"text":9510},{"id":9533,"depth":1213,"text":9534},{"id":9560,"depth":1213,"text":9561},{"id":9584,"depth":1213,"text":9585},{"id":9607,"depth":1213,"text":9608,"children":9636},[9637],{"id":9617,"depth":5848,"text":9618},"2026-07-20","Du plan à l’affectation automatique des circuits et du tableau, puis au schéma unifilaire, au plan de situation et au dossier PDF : un aperçu honnête.",{},"\u002Fblog\u002Fplanelec-capabilities-overview.fr",{"title":9288,"description":9639},"que-peut-on-faire-avec-planelec","blog\u002Fplanelec-capabilities-overview.fr",[5823,9646,8422,1248,1247,9647,9648],"planification électrique","automatisation","export PDF","plA8g7uWtzO5dV0zqN29IqoQx1NqrJI2b2trw81oXcQ",{"id":9651,"title":9652,"articleId":9653,"body":9654,"category":1228,"date":9638,"description":10082,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":10083,"navigation":1234,"path":10084,"publishDate":9638,"readTime":1994,"refreshInterval":1237,"seo":10085,"slug":10086,"stem":10087,"tags":10088,"__hash__":10096},"blog\u002Fblog\u002Frenovation-electrical-plans.fr.md","Rénovation et RGIE : Quand avez-vous besoin de nouveaux plans électriques ?","renovation-electrical-plans",{"type":9,"value":9655,"toc":10055},[9656,9660,9663,9666,9670,9702,9705,9709,9712,9715,9719,9722,9725,9729,9733,9736,9739,9743,9746,9749,9753,9756,9759,9763,9766,9769,9773,9777,9780,9784,9787,9791,9794,9798,9818,9821,9824,9828,9831,9851,9855,9862,9882,9891,9895,9898,9902,9905,9936,9940,9943,9976,9979,10006,10010,10021,10025,10050],[12,9657,9659],{"id":9658},"quand-la-rénovation-conduit-elle-à-de-nouveaux-plans-et-à-un-contrôle","Quand la rénovation conduit-elle à de nouveaux plans et à un contrôle ?",[17,9661,9662],{},"C'est la portée électrique, et non le mot « rénovation », qui décide. Le Livre 1 V06 soumet les modifications ou extensions importantes à un contrôle avant leur mise en usage. Ce contrôle est en principe limité aux parties ajoutées ou modifiées. Si les travaux influencent une partie inchangée, celle-ci est examinée pour les caractéristiques concernées et mentionnée au rapport.",[17,9664,9665],{},"Dans une installation domestique, une intervention importante entraîne la création ou la mise à jour du schéma unifilaire et du plan de situation. Pour une modification non importante, une description succincte datée et signée peut remplacer le nouveau schéma unifilaire ; le plan de situation montre néanmoins le changement. Le RGIE ne fournit pas un tableau simpliste classant toute prise déplacée. Définissez le périmètre avec l'électricien et, si nécessaire, l'organisme agréé avant le chantier.",[12,9667,9669],{"id":9668},"une-démarche-de-décision-pratique","Une démarche de décision pratique",[5034,9671,9672,9678,9684,9690,9696],{},[714,9673,9674,9677],{},[221,9675,9676],{},"Les travaux sont-ils non électriques ?"," Peinture et revêtement de sol ne modifient pas l'installation.",[714,9679,9680,9683],{},[221,9681,9682],{},"S'agit-il d'un entretien ?"," Documentez le remplacement équivalent et vérifiez que caractéristiques et protections restent identiques.",[714,9685,9686,9689],{},[221,9687,9688],{},"Ajoute-t-on câbles, circuits, sources ou tableaux ?"," Traitez le projet comme potentiellement important jusqu'à l'avis professionnel.",[714,9691,9692,9695],{},[221,9693,9694],{},"Tension, raccordement, terre ou chaîne de protection changent-ils ?"," L'effet peut dépasser le nouvel appareil.",[714,9697,9698,9701],{},[221,9699,9700],{},"Quelles parties existantes sont touchées ?"," Délimitez-les par circuit, tableau et trajet réel.",[17,9703,9704],{},"Un sous-tableau, un circuit de borne ou pompe à chaleur, un remplacement de tableau ou une conversion du raccordement demandent ainsi un examen précoce. Une plaque de finition, une lampe ou un interrupteur équivalent sans changement électrique se rapproche de l'entretien. Ces exemples ne tranchent pas un dossier réel.",[12,9706,9708],{"id":9707},"pas-de-règle-de-contamination-générale","Pas de « règle de contamination » générale",[17,9710,9711],{},"Cette expression populaire laisse croire que le moindre travail soumet automatiquement toute la maison aux règles actuelles. Le Livre 1 ne le formule pas ainsi. Le contrôle d'une modification importante vise les parties modifiées ou ajoutées. Une partie inchangée n'est incluse que pour les propriétés influencées par les travaux. Un danger indépendant peut évidemment être observé, sans créer pour autant une règle tout ou rien.",[17,9713,9714],{},"La délimitation écrite vaut mieux que le slogan. Identifiez circuits, segments de câble, protections et locaux concernés. Marquez l'existant, le neuf et les points d'alimentation ou de protection communs. Cette transparence aide la décision professionnelle, mais ne limite pas unilatéralement le contrôle agréé.",[12,9716,9718],{"id":9717},"ce-que-fait-réellement-la-partie-8","Ce que fait réellement la Partie 8",[17,9720,9721],{},"La Partie 8 contient des dérogations précises pour des parties existantes, notamment selon leur époque. Elle ne rend pas toute ancienne installation acceptable. Chaque dérogation a son domaine et souvent des conditions. Le matériel doit rester sûr et l'âge n'excuse aucun danger immédiat. Les parties nouvelles ou fortement modifiées sont étudiées selon les règles actuellement applicables.",[17,9723,9724],{},"Pour chaque zone existante, rassemblez période de pose, anciens rapports, données des câbles et protections et transformations ultérieures. Une maison des années soixante peut contenir plusieurs générations de travaux. Son année de construction ne prouve pas la dérogation applicable à un circuit.",[12,9726,9728],{"id":9727},"documentation-lors-dune-rénovation","Documentation lors d'une rénovation",[5686,9730,9732],{"id":9731},"relever-sans-hypothèse-dangereuse","Relever sans hypothèse dangereuse",[17,9734,9735],{},"Commencez par les rapports, plans, factures et étiquettes disponibles, puis comparez-les au tableau réel. Une personne qualifiée peut isoler méthodiquement les circuits et noter quels points sont effectivement coupés. Le travail sous tension ou l'ouverture d'éléments plombés ne sont pas des méthodes de relevé. Un trajet de câble supposé reste marqué comme hypothèse jusqu'à vérification.",[17,9737,9738],{},"Créez un inventaire par circuit avec repère, locaux desservis, type et section visibles, protection, groupe différentiel, boîtes connues et appareils fixes. Séparez les inconnues des faits confirmés. Les photos conservent étiquettes et état, mais ne remplacent ni mesure ni schéma.",[5686,9740,9742],{"id":9741},"découper-le-chantier-en-lots","Découper le chantier en lots",[17,9744,9745],{},"Séparez défauts de sécurité immédiats, adaptations nécessaires aux travaux et ajouts de confort. On voit ainsi ce qui doit être résolu avant mise en service. Examinez d'abord les points communs : tableau principal, terre, alimentation et différentiels partagés peuvent relier plusieurs pièces. Un nouveau circuit de cuisine est local dans le plan, mais touche électriquement le tableau.",[17,9747,9748],{},"Pour chaque lot, notez état initial, modification prévue, caractéristiques existantes influencées et état final. Ne reportez pas la qualification des travaux jusqu'après fermeture des murs. Portée du contrôle, mesures requises et accès aux points d'essai influencent le calendrier.",[5686,9750,9752],{"id":9751},"produire-létat-réalisé","Produire l'état réalisé",[17,9754,9755],{},"Ne reprenez pas les positions prévues sans visite finale. Comparez prises, interrupteurs, luminaires, boîtes et appareils fixes pièce par pièce, puis chaque circuit avec protection, câble et place au tableau. Les parties posées avant le 1er octobre 1981 sont indiquées comme anciennes lorsqu'elles figurent au schéma unifilaire.",[17,9757,9758],{},"Chaque document porte numéro, version et date de version. Une note de modification nomme brièvement locaux ou circuits traités. Conservez les anciennes versions validées : elles aident à dater les parties existantes. Les documents actuels restent disponibles sur place pour surveillance, contrôle, entretien, réparation et transformation.",[5686,9760,9762],{"id":9761},"traiter-le-rapport-de-contrôle","Traiter le rapport de contrôle",[17,9764,9765],{},"Remettez des plans lisibles et les pièces nécessaires à l'organisme. Une mesure incorrecte ou un défaut de montage ne se corrige pas graphiquement ; il faut traiter la cause technique. Après correction, réalignez installation et documents. Rapport, plans signés, mesures et preuves produit rejoignent ensuite le dossier.",[17,9767,9768],{},"PlanElec facilite repères communs et PDF entre plan, topologie, tableau et schémas. La liste matérielle détaillée et le dossier de travail sont encore des fonctions pilote à couverture déclarée. Ils ne donnent ni prix, ni commande fabricant, ni rapport officiel, ni certificat de conformité. Étude, exécution et décision restent humaines et professionnelles.",[12,9770,9772],{"id":9771},"trois-exemples-de-périmètre","Trois exemples de périmètre",[5686,9774,9776],{"id":9775},"la-salle-de-bains-est-entièrement-refaite","La salle de bains est entièrement refaite",[17,9778,9779],{},"Nouveaux câbles, prises, éclairage et protections forment un lot nouveau. Notez aussi l'alimentation et la branche existante du tableau. L'électricien vérifie volumes, protections, conducteurs et liaisons selon la réalisation. Les autres pièces ne sont pas automatiquement « contaminées », mais les propriétés communes ou influencées doivent être étudiées.",[5686,9781,9783],{"id":9782},"un-circuit-existant-est-réparé","Un circuit existant est réparé",[17,9785,9786],{},"Pour un remplacement équivalent, enregistrez type et propriétés et vérifiez le rétablissement sûr. Si emplacement, câble, protection ou fonction changent, requalifiez les travaux. Le mot réparation ne peut masquer une extension réelle.",[5686,9788,9790],{"id":9789},"le-tableau-est-remplacé","Le tableau est remplacé",[17,9792,9793],{},"Le nouveau tableau touche de nombreuses données communes. Identifiez chaque départ avant démontage. Après travaux, étiquettes, groupes différentiels, phases, conducteurs et schémas concordent avec la réalité. Un ancien circuit inconnu est clarifié avant raccordement et non prolongé sous un nom générique.",[12,9795,9797],{"id":9796},"questions-à-poser-avant-le-chantier","Questions à poser avant le chantier",[711,9799,9800,9803,9806,9809,9812,9815],{},[714,9801,9802],{},"Quelles parties sont neuves, déplacées, remplacées ou inchangées ?",[714,9804,9805],{},"Quelles données existantes sont prouvées et lesquelles demandent mesure ou accès ?",[714,9807,9808],{},"Quels points communs d'alimentation ou de protection sont touchés ?",[714,9810,9811],{},"Les travaux sont-ils importants et qui confirme cette qualification ?",[714,9813,9814],{},"Quels plans, descriptions, mesures et documents fabricant faut-il ?",[714,9816,9817],{},"Quand placer contrôle et libération documentaire dans le calendrier ?",[17,9819,9820],{},"Ces questions ne garantissent pas un résultat juridique. Elles évitent de découvrir les tâches techniques et documentaires à la veille du contrôle.",[17,9822,9823],{},"Dans un bâtiment occupé, prévoyez aussi des états intermédiaires sûrs. Les circuits inachevés restent clairement hors service et étiquetés. Une alimentation temporaire est réalisée professionnellement et documentée séparément. À chaque phase, distinguez ce qui correspond déjà au plan réalisé de ce qui reste un état de chantier.",[5686,9825,9827],{"id":9826},"maisons-avec-plans-existants","Maisons avec plans existants",[17,9829,9830],{},"Si un schéma unifilaire et un plan de situation actuels existent :",[5034,9832,9833,9839,9845],{},[714,9834,9835,9838],{},[221,9836,9837],{},"Mettre à jour les plans"," — ajouter les nouveaux circuits, positions modifiées",[714,9840,9841,9844],{},[221,9842,9843],{},"Marquer"," ce qui est ancien et ce qui est nouveau",[714,9846,9847,9850],{},[221,9848,9849],{},"Présenter les plans mis à jour"," au contrôleur",[5686,9852,9854],{"id":9853},"maisons-sans-plans-avant-1981","Maisons sans plans (avant 1981)",[17,9856,9857,9858,9861],{},"De nombreuses maisons anciennes n'ont ",[221,9859,9860],{},"pas de documentation existante",". Dans ce cas (Art. 9.1.2) :",[5034,9863,9864,9870,9876],{},[714,9865,9866,9869],{},[221,9867,9868],{},"Relever l'installation complète"," — y compris les parties inchangées",[714,9871,9872,9875],{},[221,9873,9874],{},"Créer un nouveau schéma unifilaire complet"," — pour toute l'installation",[714,9877,9878,9881],{},[221,9879,9880],{},"Établir un plan de situation"," — dessiner toutes les prises, interrupteurs, points lumineux",[9883,9884,9885],"blockquote",{},[17,9886,9887,9890],{},[221,9888,9889],{},"Attention"," : C'est l'une des raisons les plus fréquentes pour lesquelles les rénovations coûtent nettement plus cher que prévu — l'obligation de documentation pour l'ensemble de l'installation.",[12,9892,9894],{"id":9893},"prévoir-leffort-sans-prix-forfaitaire-inventé","Prévoir l'effort sans prix forfaitaire inventé",[17,9896,9897],{},"Le coût dépend du relevé, des documents manquants, du nombre de circuits, des mesures, du chantier et de l'organisme. D'anciennes fourchettes en ligne ne sont pas une offre. Demandez des devis séparés pour relevé, étude, exécution, contrôle et corrections éventuelles. PlanElec est gratuit pendant l'Early Access et aucun paiement n'est actif, mais les prestations professionnelles restent nécessaires.",[5686,9899,9901],{"id":9900},"lavantage-planelec-pour-les-rénovations","L'avantage PlanElec pour les rénovations",[17,9903,9904],{},"Avec PlanElec, vous pouvez :",[711,9906,9907,9912,9918,9924,9930],{},[714,9908,9909],{},[221,9910,9911],{},"Documenter l'installation existante",[714,9913,9914,9917],{},[221,9915,9916],{},"Ajouter des circuits"," et les examiner avec un auto-contrôle indicatif à couverture limitée",[714,9919,9920,9923],{},[221,9921,9922],{},"Séparer clairement"," ancien et nouveau",[714,9925,9926,9929],{},[221,9927,9928],{},"Exporter le résultat en PDF"," pour le contrôleur",[714,9931,9932,9935],{},[221,9933,9934],{},"Early Access actuellement gratuit"," ; aucun paiement n'est encore activé",[12,9937,9939],{"id":9938},"checklist-pour-les-rénovateurs","Checklist pour les rénovateurs",[17,9941,9942],{},"Avant le début des travaux :",[711,9944,9946,9952,9958,9964,9970],{"className":9945},[6084],[714,9947,9949,9951],{"className":9948},[6088],[6090,9950],{"disabled":1234,"type":6092}," Vérifier : Mes travaux déclenchent-ils un nouveau contrôle ?",[714,9953,9955,9957],{"className":9954},[6088],[6090,9956],{"disabled":1234,"type":6092}," Rechercher les plans électriques existants (si disponibles)",[714,9959,9961,9963],{"className":9960},[6088],[6090,9962],{"disabled":1234,"type":6092}," Prévoir un budget pour la documentation + le contrôle",[714,9965,9967,9969],{"className":9966},[6088],[6090,9968],{"disabled":1234,"type":6092}," Impliquer un électricien à temps (pour l'installation)",[714,9971,9973,9975],{"className":9972},[6088],[6090,9974],{"disabled":1234,"type":6092}," Utiliser PlanElec pour la documentation (créer les plans soi-même)",[17,9977,9978],{},"Après la rénovation :",[711,9980,9982,9988,9994,10000],{"className":9981},[6084],[714,9983,9985,9987],{"className":9984},[6088],[6090,9986],{"disabled":1234,"type":6092}," Plans mis à jour créés ?",[714,9989,9991,9993],{"className":9990},[6088],[6090,9992],{"disabled":1234,"type":6092}," Tous les nouveaux circuits dans le schéma unifilaire ?",[714,9995,9997,9999],{"className":9996},[6088],[6090,9998],{"disabled":1234,"type":6092}," Organisme de contrôle contacté ?",[714,10001,10003,10005],{"className":10002},[6088],[6090,10004],{"disabled":1234,"type":6092}," Rapport et éventuelles remarques examinés avec l'électricien ?",[12,10007,10009],{"id":10008},"source-officielle","Source officielle",[711,10011,10012,10018],{},[714,10013,10014],{},[203,10015,10017],{"href":5371,"rel":10016},[5373],"SPF Économie : RGIE Livre 1, Version 06",[714,10019,10020],{},"Voir surtout section 3.1.2, sous-section 6.4.7.3, Partie 8 et obligations de dossier de la Partie 9.",[12,10022,10024],{"id":10023},"articles-connexes","Articles connexes",[711,10026,10027,10033,10038,10044],{},[714,10028,10029],{},[203,10030,10032],{"href":10031},"\u002Ffr\u002Fblog\u002Fancien-rgie-part-8","L'électricité dans les bâtiments anciens en Belgique : Part 8 du RGIE expliqué",[714,10034,10035],{},[203,10036,10037],{"href":205},"Combien coûte un plan électrique ? Comparatif de prix 2026",[714,10039,10040],{},[203,10041,10043],{"href":10042},"\u002Ffr\u002Fblog\u002Fque-verifie-controleur-inspection","Que vérifie le contrôleur lors de l'inspection ?",[714,10045,10046],{},[203,10047,10049],{"href":10048},"\u002Ffr\u002Fblog\u002Fdossier-electrique-vente-immobiliere","Dossier électrique lors de la vente immobilière",[17,10051,10052],{},[203,10053,10054],{"href":7861},"Documenter l'état rénové de manière traçable dans PlanElec →",{"title":1212,"searchDepth":1213,"depth":1213,"links":10056},[10057,10058,10059,10060,10061,10067,10072,10076,10079,10080,10081],{"id":9658,"depth":1213,"text":9659},{"id":9668,"depth":1213,"text":9669},{"id":9707,"depth":1213,"text":9708},{"id":9717,"depth":1213,"text":9718},{"id":9727,"depth":1213,"text":9728,"children":10062},[10063,10064,10065,10066],{"id":9731,"depth":5848,"text":9732},{"id":9741,"depth":5848,"text":9742},{"id":9751,"depth":5848,"text":9752},{"id":9761,"depth":5848,"text":9762},{"id":9771,"depth":1213,"text":9772,"children":10068},[10069,10070,10071],{"id":9775,"depth":5848,"text":9776},{"id":9782,"depth":5848,"text":9783},{"id":9789,"depth":5848,"text":9790},{"id":9796,"depth":1213,"text":9797,"children":10073},[10074,10075],{"id":9826,"depth":5848,"text":9827},{"id":9853,"depth":5848,"text":9854},{"id":9893,"depth":1213,"text":9894,"children":10077},[10078],{"id":9900,"depth":5848,"text":9901},{"id":9938,"depth":1213,"text":9939},{"id":10008,"depth":1213,"text":10009},{"id":10023,"depth":1213,"text":10024},"Une rénovation n'exige pas toujours les mêmes documents. Distinguez modification importante, parties existantes, mise à jour des plans et contrôle.",{},"\u002Fblog\u002Frenovation-electrical-plans.fr",{"title":9652,"description":10082},"renovation-rgie-plans-electriques","blog\u002Frenovation-electrical-plans.fr",[1243,1242,10089,10090,10091,10092,10093,10094,10093,1248,8422,1249,10095],"rénovation","travaux","plans électriques","nouveau contrôle","installation existante","Part 8","contrôle électrique","fNe4drehMV8I8i5z7UdbLNKY_iRqKEttoZv4SmyQwgg",{"id":10098,"title":10099,"articleId":10100,"body":10101,"category":10248,"date":10249,"description":10250,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":10251,"navigation":1234,"path":10252,"publishDate":10249,"readTime":10253,"refreshInterval":1237,"seo":10254,"slug":10255,"stem":10256,"tags":10257,"__hash__":10267},"blog\u002Fblog\u002Fdedicated-circuits-appliances.fr.md","Circuit dédié obligatoire : Quels appareils nécessitent leur propre disjoncteur ?","dedicated-circuits-appliances",{"type":9,"value":10102,"toc":10239},[10103,10107,10114,10117,10121,10124,10144,10148,10151,10154,10158,10161,10180,10188,10192,10195,10197,10215,10219,10233],[12,10104,10106],{"id":10105},"quels-appareils-exigent-un-circuit-séparé","Quels appareils exigent un circuit séparé ?",[17,10108,10109,10110,10113],{},"Le Livre 1 V06 du RGIE, sous-section 5.2.1.2, pose deux règles. Tout appareil fixe ou mobile à poste fixe dont la puissance nominale atteint ",[221,10111,10112],{},"2 600 W"," est alimenté séparément par un circuit distinct. Indépendamment de ce seuil, le lave-linge, le lave-vaisselle, le sèche-linge, la cuisinière électrique, la taque électrique et le four électrique disposent chacun d'un circuit exclusivement destiné à cet appareil. Les appareils fixes de chauffage électrique sont alimentés par un ou plusieurs circuits distincts.",[17,10115,10116],{},"Cette prescription définit la structure du circuit, pas un calibre ni une section universels. Il faut encore tenir compte de la plaque signalétique, du réseau, du mode de pose, du matériau, de la température, du groupement, de la longueur, de la variation de tension, de la protection contre les défauts et de la notice du fabricant. Une même valeur pour tous les fours, pompes à chaleur ou chargeurs serait trompeuse.",[12,10118,10120],{"id":10119},"pourquoi-un-circuit-dédié","Pourquoi un circuit dédié ?",[17,10122,10123],{},"Trois raisons pour lesquelles le RGIE impose des circuits dédiés :",[5034,10125,10126,10132,10138],{},[714,10127,10128,10131],{},[221,10129,10130],{},"Sécurité"," : Les appareils de forte puissance sollicitent le circuit en permanence près de sa limite. Un circuit partagé peut surchauffer.",[714,10133,10134,10137],{},[221,10135,10136],{},"Disponibilité"," : Si le disjoncteur déclenche, seul l'appareil concerné est coupé — pas toute la cuisine.",[714,10139,10140,10143],{},[221,10141,10142],{},"Protection des câbles"," : La section du câble peut être adaptée exactement à l'appareil.",[12,10145,10147],{"id":10146},"appliquer-la-règle-appareil-par-appareil","Appliquer la règle appareil par appareil",[17,10149,10150],{},"Commencez par la plaque signalétique et la notice. Relevez la puissance, les phases, le raccordement admis et les protections spécifiques. Une cuisinière combinée ne se traite pas nécessairement comme une taque et un four séparés ; une pompe à chaleur peut demander des alimentations distinctes pour unités extérieure, intérieure et appoint. Ces cas ne doivent pas être réduits à un modèle unique.",[17,10152,10153],{},"Sur le schéma unifilaire, attribuez à chaque circuit exclusif une référence, une protection, les données de canalisation et l'appareil terminal. Le plan de position reprend la même référence à l'emplacement réel. Après remplacement d'un appareil, vérifiez de nouveau le dimensionnement.",[12,10155,10157],{"id":10156},"buanderie-local-technique","Buanderie \u002F local technique",[17,10159,10160],{},"Même principe : chaque gros appareil obtient son propre circuit :",[711,10162,10163,10169,10174],{},[714,10164,10165,10168],{},[221,10166,10167],{},"Lave-linge"," : circuit exclusif dimensionné selon l'appareil et la pose",[714,10170,10171,10168],{},[221,10172,10173],{},"Sèche-linge",[714,10175,10176,10179],{},[221,10177,10178],{},"Chauffe-eau"," : circuit distinct dès que le seuil de 2 600 W à poste fixe est atteint",[9883,10181,10182],{},[17,10183,10184,10187],{},[221,10185,10186],{},"Conseil"," : Prévoyez également dans la buanderie un circuit de prises séparé pour le fer à repasser et autres consommateurs.",[12,10189,10191],{"id":10190},"planelec-aide-à-contrôler-les-circuits-dédiés","PlanElec aide à contrôler les circuits dédiés",[17,10193,10194],{},"L'auto-contrôle PlanElec peut signaler, pour les appareils pris en charge, qu'aucun circuit dédié n'est renseigné. L'alerte reste une aide à la planification et ne remplace ni le dimensionnement professionnel ni le contrôle officiel.",[12,10196,10024],{"id":10023},[711,10198,10199,10204,10210],{},[714,10200,10201],{},[203,10202,10203],{"href":1579},"Quelle section de câble pour quel disjoncteur ?",[714,10205,10206],{},[203,10207,10209],{"href":10208},"\u002Ffr\u002Fblog\u002F30ma-ddr-par-prise","Ai-je besoin d'un différentiel 30mA par prise ?",[714,10211,10212],{},[203,10213,10214],{"href":4789},"Combien de prises par circuit ?",[12,10216,10218],{"id":10217},"sources-et-limites","Sources et limites",[711,10220,10221,10228],{},[714,10222,10223,10227],{},[203,10224,10226],{"href":5371,"rel":10225},[5373],"SPF Économie — Livre 1 V06 du RGIE"," — sous-section 5.2.1.2 et règles complètes de dimensionnement.",[714,10229,10230,10232],{},[203,10231,7847],{"href":6216}," — contexte du dossier et du contrôle.",[17,10234,10235,10236],{},"PlanElec peut consigner ces circuits et signaler certaines affectations manquantes. L'autocontrôle reste indicatif : il ne lit pas la notice, ne connaît pas toutes les conditions de pose et ne remplace pas l'évaluation officielle. ",[203,10237,10238],{"href":7861},"Commencer la planification →",{"title":1212,"searchDepth":1213,"depth":1213,"links":10240},[10241,10242,10243,10244,10245,10246,10247],{"id":10105,"depth":1213,"text":10106},{"id":10119,"depth":1213,"text":10120},{"id":10146,"depth":1213,"text":10147},{"id":10156,"depth":1213,"text":10157},{"id":10190,"depth":1213,"text":10191},{"id":10023,"depth":1213,"text":10024},{"id":10217,"depth":1213,"text":10218},"faq","2026-07-13","Cuisinière, lave-linge, sèche-linge — le RGIE impose un circuit dédié pour certains appareils. Voici la liste complète.",{},"\u002Fblog\u002Fdedicated-circuits-appliances.fr","3 min",{"title":10099,"description":10250},"circuit-dedie-obligatoire-appareils","blog\u002Fdedicated-circuits-appliances.fr",[1243,1242,10258,10259,10260,10261,10262,10263,10264,10265,10266,1249,10095],"circuit dédié","circuit individuel","lave-linge","sèche-linge","cuisinière","lave-vaisselle","chauffe-eau","disjoncteur","section câble","_P_wMxaGvI3q-jh4Fxje20pw1fNCadISKpsjlSMbZlY",{"id":10269,"title":10270,"articleId":10271,"body":10272,"category":1228,"date":10565,"description":10566,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":10567,"navigation":1234,"path":10568,"publishDate":10569,"readTime":1994,"refreshInterval":7920,"seo":10570,"slug":10571,"stem":10572,"tags":10573,"__hash__":10579},"blog\u002Fblog\u002Fgetting-started-guide.fr.md","Premiers pas avec PlanElec : du plan au premier export","getting-started-guide",{"type":9,"value":10273,"toc":10545},[10274,10280,10284,10291,10294,10298,10304,10307,10311,10314,10317,10321,10324,10327,10330,10334,10337,10343,10347,10353,10356,10360,10363,10366,10370,10375,10381,10385,10388,10392,10395,10399,10402,10406,10409,10413,10416,10419,10423,10455,10459,10462,10465,10468,10471,10475,10498,10502,10528,10531],[17,10275,10276,10277],{},"PlanElec accompagne le projet depuis le plan spatial jusqu'au tableau, au schéma unifilaire et aux documents, en passant par la topologie électrique. Le principe essentiel pour bien débuter est le suivant : ",[221,10278,10279],{},"un symbole sur le plan indique d'abord une position ; son affectation électrique en fait ensuite un élément du schéma.",[12,10281,10283],{"id":10282},"_1-créer-le-projet-le-bâtiment-et-les-étages","1. Créer le projet, le bâtiment et les étages",[17,10285,10286,10287,10290],{},"Après connexion, ouvrez la liste des projets et choisissez ",[221,10288,10289],{},"Créer un projet",". Vous pouvez démarrer avec le parcours guidé, un modèle ou un projet vide. Pour un premier projet, le parcours guidé est recommandé car il détermine la prochaine étape à partir de l'état réel des données.",[17,10292,10293],{},"Créez ensuite le bâtiment et ses étages. Ouvrez les métadonnées du projet et renseignez le nom, l'adresse de l'installation et l'installateur. Ces informations alimenteront les cartouches, le rapport d'auto-contrôle et le dossier.",[12,10295,10297],{"id":10296},"_2-dessiner-le-plan-et-créer-les-pièces","2. Dessiner le plan et créer les pièces",[17,10299,10300,10301,10303],{},"Dans la section ",[221,10302,9336],{},", dessinez les murs extérieurs et intérieurs sous forme de polygone ou de rectangle. Vous pouvez aussi importer un plan existant comme image de référence et le calibrer sur une distance connue.",[17,10305,10306],{},"Lorsque les murs délimitent une surface fermée, PlanElec reconnaît une pièce. Nommez et classez chaque pièce. Cela facilite ensuite le choix des équipements, la vue matériel et le contrôle professionnel.",[12,10308,10310],{"id":10309},"_3-placer-les-équipements-électriques","3. Placer les équipements électriques",[17,10312,10313],{},"Ouvrez la palette et placez les prises, interrupteurs, luminaires, raccordements fixes, boîtes de connexion et le tableau à leur position prévue. Les équipements muraux s'alignent sur le mur, tandis que les luminaires peuvent rester libres dans la pièce.",[17,10315,10316],{},"Dans les pièces appropriées, PlanElec peut proposer des prises, de l'éclairage, un équipement standard ou une grille de spots. Vérifiez chaque proposition en tenant compte des portes, fenêtres, éléments fixes, usages et zones humides. L'automatisation fournit un point de départ modifiable, pas une étude professionnelle terminée.",[12,10318,10320],{"id":10319},"_4-relier-interrupteurs-récepteurs-et-topologie","4. Relier interrupteurs, récepteurs et topologie",[17,10322,10323],{},"Reliez les interrupteurs aux luminaires associés. Une chaîne peut être proposée pour les éléments encore libres d'une pièce. Contrôlez ensuite la liste des composants non connectés.",[17,10325,10326],{},"Affectez les récepteurs au tableau et au circuit appropriés. L'affectation automatique peut regrouper les points d'éclairage et les prises ordinaires et traiter séparément les appareils spéciaux pris en charge. Vérifiez les protections, la phase et les données de câble avant d'accepter la proposition.",[17,10328,10329],{},"Une boîte de connexion ou de dérivation doit être reliée comme un vrai nœud topologique pour diviser le câble en plusieurs segments. La proximité spatiale d'une boîte ne suffit pas pour l'insérer automatiquement dans le chemin électrique.",[12,10331,10333],{"id":10332},"_5-contrôler-les-chemins-de-câble","5. Contrôler les chemins de câble",[17,10335,10336],{},"Pour les équipements connectés, PlanElec peut calculer un trajet de câble le long des murs. Vérifiez le départ, l'arrivée et le parcours, puis ajoutez des points de passage manuels si nécessaire. Une longueur déterminée professionnellement peut remplacer la longueur calculée.",[17,10338,10339,10340,10342],{},"Le type, la section, le mode de pose et la longueur du câble doivent correspondre à l'installation réelle. Le guide ",[203,10341,9442],{"href":9441}," réunit le déroulement pour les récepteurs, les câbles, les circuits et le tableau.",[12,10344,10346],{"id":10345},"_6-remplir-le-tableau-électrique","6. Remplir le tableau électrique",[17,10348,10349,10350,10352],{},"Ouvrez la section ",[221,10351,50],{},", choisissez le coffret et la configuration des pôles, puis lancez le placement automatique. Les interrupteurs principaux, différentiels et disjoncteurs déjà présents sont disposés sur les rails DIN, avec une réserve de place prévue par défaut.",[17,10354,10355],{},"Contrôlez ensuite la largeur des modules, les groupes protégés et les connexions. Ajoutez les relations manquantes avec l'outil de liaison ou déplacez les modules manuellement. Dans une installation polyphasée, vérifiez également l'aperçu des phases.",[12,10357,10359],{"id":10358},"_7-contrôler-le-schéma-unifilaire-et-lauto-contrôle","7. Contrôler le schéma unifilaire et l'auto-contrôle",[17,10361,10362],{},"Le schéma unifilaire est dérivé de la topologie électrique. Vérifiez que les branches de récepteurs, protections, données de câble et dérivations sont complètes. Si une affectation est incorrecte, corrigez la relation dans le modèle de projet commun, puis contrôlez à nouveau le schéma.",[17,10364,10365],{},"L'auto-contrôle RGIE signale des constats dans les domaines actuellement pris en charge et évaluables à partir des données du projet. L'absence d'erreur ne garantit pas la conformité et ne remplace pas le contrôle officiel.",[12,10367,10369],{"id":10368},"_8-exporter-les-documents","8. Exporter les documents",[17,10371,10300,10372,10374],{},[221,10373,1025],{},", vous pouvez produire en PDF le schéma unifilaire, le plan de situation et le rapport indicatif d'auto-contrôle. Le flux de développement\u002Fpilote ajoute les listes de circuits, de matériel et de câbles ainsi qu'un dossier de travail sélectionnable. Le PDF du tableau n'apparaît que si le feature flag est actif et si le tableau contient des données.",[17,10376,10377,10378,10380],{},"Avant toute transmission, contrôlez les métadonnées, la lisibilité, l'ordre des pages et les constats ouverts. La page ",[203,10379,9491],{"href":9490}," détaille le statut de chaque sortie.",[12,10382,10384],{"id":10383},"réaliser-un-premier-cycle-fiable","Réaliser un premier cycle fiable",[17,10386,10387],{},"Pour apprendre, limitez le premier projet à un périmètre réel : un niveau, un tableau, deux circuits de prises, l'éclairage et un appareil fixe suffisent. Vous distinguerez ainsi les informations spatiales, électriques et documentaires. Un symbole répond à la question « où ? ». Son circuit, sa protection et son câble répondent à « comment est-il alimenté ? ». L'export rapproche ces vues sans inventer les mesures manquantes.",[5686,10389,10391],{"id":10390},"inventorier-avant-de-dessiner","Inventorier avant de dessiner",[17,10393,10394],{},"Relevez les indications visibles de tension et de raccordement, les tableaux, étages, pièces et points électriques. N'ouvrez jamais une partie plombée et ne déduisez pas le réseau du seul nombre de fils visibles. Pour une installation existante, des photos d'étiquettes et un relevé prudent par un professionnel valent mieux qu'une hypothèse. Laissez une section ou un calibre inconnus comme donnée ouverte au lieu d'inscrire une valeur vraisemblable.",[5686,10396,10398],{"id":10397},"contrôler-séparément-appareils-et-circuits","Contrôler séparément appareils et circuits",[17,10400,10401],{},"Placez d'abord le tableau et les équipements réellement présents. Reliez les interrupteurs aux luminaires qu'ils commandent, puis affectez les récepteurs aux circuits. Examinez chaque proposition de planification. PlanElec fournit un éditeur guidé et des suggestions, pas une approbation professionnelle automatique. Mode de pose, groupement, température, longueur, chute de tension, courant de défaut et consignes du fabricant peuvent rester hors des données enregistrées.",[5686,10403,10405],{"id":10404},"aligner-les-trois-vues","Aligner les trois vues",[17,10407,10408],{},"Utilisez les mêmes repères dans le tableau, le schéma unifilaire et le plan de situation. Après le déplacement d'un appareil, la division d'un circuit ou le remplacement d'une protection, contrôlez les trois. Une personne extérieure doit pouvoir partir d'un symbole spatial, retrouver le circuit puis le module réel du tableau. Si ce parcours échoue, le dossier n'est pas prêt.",[5686,10410,10412],{"id":10411},"faire-de-lexport-une-étape-de-revue","Faire de l'export une étape de revue",[17,10414,10415],{},"Commencez par les aperçus. Vérifiez coupures de pages, textes tronqués, légende, adresse, responsable, version et date. Rouvrez ensuite les PDF et comparez-les au projet actuel. Les PDF unifilaire et situation sont disponibles dans le flux normal. La liste détaillée de matériel et le dossier de travail restent des fonctions pilote avec des limites de couverture visibles ; ils ne constituent ni bon de commande ni rapport officiel.",[17,10417,10418],{},"L'auto-contrôle RGIE est indicatif. L'absence d'erreur signifie seulement qu'aucune règle prise en charge et décidable à partir des données n'a signalé de problème. Mesures, instructions produit, conditions du chantier et prescriptions non modélisées restent à vérifier. Faites relire projet, réalisation et documents par un électricien qualifié avant mise en service et contrôle.",[12,10420,10422],{"id":10421},"diagnostiquer-un-écart","Diagnostiquer un écart",[711,10424,10425,10431,10437,10443,10449],{},[714,10426,10427,10430],{},[221,10428,10429],{},"Équipement absent du schéma :"," vérifiez son affectation électrique, pas seulement sa position.",[714,10432,10433,10436],{},[221,10434,10435],{},"Circuit absent du plan :"," cherchez les objets non placés ou mal référencés.",[714,10438,10439,10442],{},[221,10440,10441],{},"Calibre douteux :"," résolvez d'abord les données de câble et l'étude professionnelle.",[714,10444,10445,10448],{},[221,10446,10447],{},"Anciennes données dans le PDF :"," contrôlez métadonnées, version et dernier enregistrement.",[714,10450,10451,10454],{},[221,10452,10453],{},"Auto-contrôle incomplet :"," complétez les données ; incomplet ne signifie jamais réussi.",[12,10456,10458],{"id":10457},"versions-collaboration-et-fin-réelle","Versions, collaboration et fin réelle",[17,10460,10461],{},"Donnez des noms stables au projet et aux étages. Avant une proposition automatique importante ou une restructuration, vérifiez l'enregistrement et créez si utile un export de comparaison. Une variante de conception n'est pas l'installation réalisée. Identifiez clairement l'option prévue, abandonnée ou exécutée.",[17,10463,10464],{},"À plusieurs, attribuez la responsabilité du plan, des affectations, du tableau et de la relecture finale. Une référence de circuit commune ne se renomme pas discrètement. Une note brève avec date, zone concernée et auteur évite de mélanger une version spatiale récente avec une ancienne version électrique.",[17,10466,10467],{},"Pour s'exercer, achevez une cuisine entière : pièce, prises, éclairage, commandes et appareils fixes réellement prévus. N'inventez pas câble ou disjoncteur à partir du seul nom d'appareil. Contrôlez ensuite trois équipements depuis leur symbole jusqu'au tableau et en sens inverse. Étendez la méthode aux autres pièces seulement lorsque cette chaîne fonctionne.",[17,10469,10470],{},"Une PDF ne suffit pas à déclarer le projet fini. Les positions doivent correspondre au bâtiment, les affectations rester traçables, les trois vues partager leurs repères, les inconnues être visibles et les décisions pertinentes être relues par un professionnel. Le contrôle porte sur la réalisation, pas sur la vitesse de génération.",[12,10472,10474],{"id":10473},"guides-associés-et-source","Guides associés et source",[711,10476,10477,10482,10487,10492],{},[714,10478,10479],{},[203,10480,10481],{"href":3283},"Créer le schéma unifilaire",[714,10483,10484],{},[203,10485,10486],{"href":1966},"Dessiner le plan de situation",[714,10488,10489],{},[203,10490,10491],{"href":567},"Planifier le tableau",[714,10493,10494],{},[203,10495,10497],{"href":5371,"rel":10496},[5373],"SPF Économie : livres officiels RGIE, Livre 1 V06",[12,10499,10501],{"id":10500},"liste-de-contrôle","Liste de contrôle",[711,10503,10504,10507,10510,10513,10516,10519,10522,10525],{},[714,10505,10506],{},"Le bâtiment, les étages et les pièces sont entièrement créés.",[714,10508,10509],{},"Tous les équipements électriques se trouvent à la bonne position.",[714,10511,10512],{},"Les récepteurs sont reliés à la topologie, au circuit et au tableau.",[714,10514,10515],{},"Les trajets et longueurs de câble ont été contrôlés.",[714,10517,10518],{},"La chaîne de protection et le placement du tableau sont plausibles.",[714,10520,10521],{},"Le schéma unifilaire et le plan de situation ont été vérifiés visuellement.",[714,10523,10524],{},"Les métadonnées du projet sont complètes pour la version du document.",[714,10526,10527],{},"Les constats et lacunes de couverture ont été compris et évalués.",[17,10529,10530],{},"PlanElec ne remplace ni l'étude et l'exécution professionnelles, ni le contrôle officiel. Faites vérifier le résultat par un électricien qualifié avant les travaux. Seul un organisme de contrôle agréé rend l'évaluation officielle.",[17,10532,10533,10534,10536,10537,10540,10541,10544],{},"Retrouvez d'autres instructions dans la ",[203,10535,9576],{"href":9575}," et l'ensemble du périmètre dans la ",[203,10538,10539],{"href":9570},"vue des fonctionnalités",". Vous pouvez ",[203,10542,10543],{"href":9580},"vous inscrire à PlanElec"," pendant l'Early Access actuel.",{"title":1212,"searchDepth":1213,"depth":1213,"links":10546},[10547,10548,10549,10550,10551,10552,10553,10554,10555,10561,10562,10563,10564],{"id":10282,"depth":1213,"text":10283},{"id":10296,"depth":1213,"text":10297},{"id":10309,"depth":1213,"text":10310},{"id":10319,"depth":1213,"text":10320},{"id":10332,"depth":1213,"text":10333},{"id":10345,"depth":1213,"text":10346},{"id":10358,"depth":1213,"text":10359},{"id":10368,"depth":1213,"text":10369},{"id":10383,"depth":1213,"text":10384,"children":10556},[10557,10558,10559,10560],{"id":10390,"depth":5848,"text":10391},{"id":10397,"depth":5848,"text":10398},{"id":10404,"depth":5848,"text":10405},{"id":10411,"depth":5848,"text":10412},{"id":10421,"depth":1213,"text":10422},{"id":10457,"depth":1213,"text":10458},{"id":10473,"depth":1213,"text":10474},{"id":10500,"depth":1213,"text":10501},"2026-07-07","Guide pas à pas : créer le projet et ses étages, dessiner le plan de situation, connecter les récepteurs, contrôler le tableau et exporter les PDF.",{},"\u002Fblog\u002Fgetting-started-guide.fr","2026-07-14",{"title":10270,"description":10566},"premiers-pas-planelec","blog\u002Fgetting-started-guide.fr",[10574,10575,10576,8422,10577,1247,10578],"premiers pas","onboarding","plan","récepteurs","export","XhRk0WG5-Y4GljQUOvSBEXMYvIupCNk7ntHk5r9Zp_w",{"id":10581,"title":10582,"articleId":10583,"body":10584,"category":10248,"date":10770,"description":10771,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":10772,"navigation":1234,"path":10773,"publishDate":10770,"readTime":10253,"refreshInterval":1237,"seo":10774,"slug":10775,"stem":10776,"tags":10777,"__hash__":10783},"blog\u002Fblog\u002Fsurge-protection-spd-mandatory.fr.md","Parafoudre selon le RGIE — Ce qu'il faut savoir","surge-protection-spd-mandatory",{"type":9,"value":10585,"toc":10761},[10586,10590,10597,10601,10608,10666,10670,10680,10686,10693,10696,10700,10703,10707,10710,10724,10732,10736,10744,10746,10756],[12,10587,10589],{"id":10588},"protection-contre-les-surtensions-dans-le-rgie","Protection contre les surtensions dans le RGIE",[17,10591,10592,10593,10596],{},"Le RGIE prescrit dans l'Art. 4.5.1 comme ",[221,10594,10595],{},"principe général"," que les personnes et les biens doivent être protégés contre les effets nuisibles des surtensions — entre autres les phénomènes atmosphériques et les surtensions de commutation. Toutefois, le RGIE ne contient pas d'obligation explicite pour un type de SPD spécifique (p.ex. « Type 2 »). La mise en œuvre concrète suit l'analyse de risques du projet et les prescriptions du fabricant.",[12,10598,10600],{"id":10599},"quest-ce-quun-parafoudre","Qu'est-ce qu'un parafoudre ?",[17,10602,10603,10604,10607],{},"Un SPD (Surge Protection Device) protège vos appareils électriques contre les ",[221,10605,10606],{},"pics de surtension"," causés par la foudre, les commutations dans le réseau ou d'autres perturbations. Ces pics peuvent détruire l'électronique sensible comme les ordinateurs, téléviseurs, pompes à chaleur et onduleurs.",[21,10609,10610,10623],{},[24,10611,10612],{},[27,10613,10614,10617,10620],{},[30,10615,10616],{},"Type SPD",[30,10618,10619],{},"Protection contre",[30,10621,10622],{},"Lieu d'installation",[43,10624,10625,10638,10653],{},[27,10626,10627,10632,10635],{},[48,10628,10629],{},[221,10630,10631],{},"Type 1",[48,10633,10634],{},"Foudre directe",[48,10636,10637],{},"Au raccordement principal (uniquement avec paratonnerre externe)",[27,10639,10640,10645,10648],{},[48,10641,10642],{},[221,10643,10644],{},"Type 2",[48,10646,10647],{},"Surtension indirecte",[48,10649,10650],{},[221,10651,10652],{},"Au tableau principal — recommandé",[27,10654,10655,10660,10663],{},[48,10656,10657],{},[221,10658,10659],{},"Type 3",[48,10661,10662],{},"Surtension résiduelle",[48,10664,10665],{},"À la prise (protection fine, optionnel)",[12,10667,10669],{"id":10668},"où-installer-le-spd","Où installer le SPD ?",[17,10671,10672,10673,10676,10677,1096],{},"Le SPD Type 2 s'installe dans le tableau de distribution. Une variante courante est ",[221,10674,10675],{},"après le différentiel principal"," (DDR) et ",[221,10678,10679],{},"avant les circuits de départ",[5508,10681,10684],{"className":10682,"code":10683,"language":5513},[5511],"Réseau → Interrupteur principal → Différentiel principal (300mA) → SPD Type 2 → Différentiels de groupe → Disjoncteurs\n",[4068,10685,10683],{"__ignoreMap":1212},[17,10687,10688,10689,10692],{},"Le SPD peut aussi être installé directement après l'interrupteur principal, ",[221,10690,10691],{},"avant"," le différentiel principal, avec son propre fusible de protection — selon les prescriptions du fabricant et le concept d'installation.",[17,10694,10695],{},"Le schéma reprend le SPD réel, son raccordement et ses protections. Emplacement, protection amont, longueur, terre et coordination suivent l'analyse de risques et le fabricant ; « typiquement 20 A » n'est pas une règle RGIE générale.",[12,10697,10699],{"id":10698},"cela-sapplique-t-il-aux-installations-existantes","Cela s'applique-t-il aux installations existantes ?",[17,10701,10702],{},"Il n'existe pas de réponse universelle. Il faut vérifier dispositions transitoires, date et portée des modifications et analyse de risques. La section 4.5.1 fixe des objectifs, pas « type 2 à ajouter dans chaque logement ». Un professionnel évalue foudre, alimentation, parcours, matériel et fabricant.",[12,10704,10706],{"id":10705},"spd-et-panneaux-photovoltaïques-pv","SPD et panneaux photovoltaïques (PV)",[17,10708,10709],{},"Pour le PV, les côtés AC et DC sont évalués séparément :",[711,10711,10712,10718],{},[714,10713,10714,10717],{},[221,10715,10716],{},"Côté AC"," (courant alternatif) : SPD Type 2 dans le tableau principal — comme décrit ci-dessus",[714,10719,10720,10723],{},[221,10721,10722],{},"Côté DC"," (courant continu) : SPD Type 2 à l'onduleur — protège les modules et l'onduleur contre les dommages de foudre. Le RGIE (Chapitre 7.112) n'impose pas explicitement de SPD côté DC pour les installations PV domestiques ; un SPD DC à l'onduleur est néanmoins vivement recommandé par les règles de l'art et les prescriptions du fabricant, en particulier en cas de longs câbles DC ou de câblage passant sur le toit (risque accru de foudre)",[9883,10725,10726],{},[17,10727,10728,10731],{},[221,10729,10730],{},"Important"," : De nombreux onduleurs disposent déjà d'un SPD DC intégré. Consultez la fiche technique de votre onduleur.",[12,10733,10735],{"id":10734},"source-et-limite-de-planification","Source et limite de planification",[17,10737,10738,10739,10743],{},"La source primaire est le ",[203,10740,10742],{"href":5371,"rel":10741},[5373],"RGIE Livre 1 version 06 du SPF Économie",", notamment l'objectif de la section 4.5.1. Le coût dépend des pôles, capacité d'écoulement, foudre, protection amont, place et travaux : utilisez une offre actuelle. PlanElec documente le choix et fournit un auto-contrôle limité, sans garantir étude ni conformité.",[12,10745,10024],{"id":10023},[711,10747,10748,10752],{},[714,10749,10750],{},[203,10751,10209],{"href":10208},[714,10753,10754],{},[203,10755,10043],{"href":10042},[17,10757,10758],{},[203,10759,10760],{"href":7861},"Documenter les protections choisies dans PlanElec →",{"title":1212,"searchDepth":1213,"depth":1213,"links":10762},[10763,10764,10765,10766,10767,10768,10769],{"id":10588,"depth":1213,"text":10589},{"id":10599,"depth":1213,"text":10600},{"id":10668,"depth":1213,"text":10669},{"id":10698,"depth":1213,"text":10699},{"id":10705,"depth":1213,"text":10706},{"id":10734,"depth":1213,"text":10735},{"id":10023,"depth":1213,"text":10024},"2026-07-06","Le RGIE prescrit une protection générale contre les surtensions (Art. 4.5.1), sans imposer un type de SPD spécifique. Découvrez ce que le RGIE exige réellement.",{},"\u002Fblog\u002Fsurge-protection-spd-mandatory.fr",{"title":10582,"description":10771},"parafoudre-obligatoire-rgie","blog\u002Fsurge-protection-spd-mandatory.fr",[1243,1242,10778,10779,10780,10781,10644,10782,1247,1249,10095],"parafoudre","SPD","Surge Protection Device","protection contre la foudre","nouvelle installation","BE_XA3yft0tU_pncHAT2VBc_BhXf-1C3_xRDoMtA0QU",{"id":10785,"title":10786,"articleId":10787,"body":10788,"category":1228,"date":11121,"description":11122,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":11123,"navigation":1234,"path":11124,"publishDate":11121,"readTime":5863,"refreshInterval":1237,"seo":11125,"slug":11126,"stem":11127,"tags":11128,"__hash__":11132},"blog\u002Fblog\u002Fproperty-sale-electrical-dossier.fr.md","Dossier électrique lors d’une vente en 2026 : règles et documents","property-sale-electrical-dossier",{"type":9,"value":10789,"toc":11101},[10790,10794,10805,10808,10812,10819,10822,10839,10842,10846,10849,10852,10856,10859,10883,10886,10890,10893,10896,10916,10919,10923,10930,10933,10937,10940,10944,10947,10951,10954,10957,10961,10964,10967,10971,10974,10978,10981,10984,10988,10991,10995,11040,11044,11047,11050,11064,11068,11071,11075,11091,11096],[12,10791,10793],{"id":10792},"visite-de-vente-et-dossier-électrique-deux-questions-distinctes","Visite de vente et dossier électrique : deux questions distinctes",[17,10795,10796,10797,10800,10801,10804],{},"Lors d'une vente immobilière belge, il faut distinguer : ",[221,10798,10799],{},"la vente déclenche-t-elle une visite de contrôle particulière ?"," Et : ",[221,10802,10803],{},"quelles pièces doivent accompagner l'installation électrique ?"," La phrase “sans dossier complet, le notaire ne peut pas passer l'acte” est trop absolue. Le Livre 1 organise contrôle, information et remise des documents selon le cas concret.",[17,10806,10807],{},"Ce guide s'appuie sur le RGIE Livre 1, version 06, applicable depuis le 1er avril 2026. Il traite des obligations électriques, pas de toutes les formalités immobilières régionales ou notariales.",[12,10809,10811],{"id":10810},"dans-quel-cas-la-visite-de-vente-est-elle-requise","Dans quel cas la visite de vente est-elle requise ?",[17,10813,10814,10815,10818],{},"La section 8.4.2 vise la vente d'une unité d'habitation équipée d'une ",[221,10816,10817],{},"ancienne installation domestique"," qui n'a pas encore subi le contrôle de conformité concerné. Avant le transfert, un organisme agréé effectue la visite. Le vendeur remet le rapport au notaire, qui informe l'acquéreur de son contenu et des obligations éventuelles.",[17,10820,10821],{},"Ce mécanisme ne couvre pas indistinctement chaque bâtiment vendu. Il faut déterminer :",[711,10823,10824,10827,10830,10833,10836],{},[714,10825,10826],{},"s'agit-il d'une unité d'habitation et d'une installation domestique ?",[714,10828,10829],{},"l'installation relève-t-elle des anciennes installations du Livre 1, partie 8 ?",[714,10831,10832],{},"existe-t-il déjà un rapport pertinent ?",[714,10834,10835],{},"l'installation a-t-elle été étendue, modifiée de façon importante ou entièrement rénovée ?",[714,10837,10838],{},"une exception expresse s'applique-t-elle ?",[17,10840,10841],{},"La partie 8 prévoit notamment une exception lorsque l'unité sera démolie ou l'installation entièrement rénovée et que cet engagement figure dans l'acte. Une vente judiciaire ne suit pas nécessairement le même processus. Le notaire et l'organisme agréé doivent qualifier la situation réelle.",[12,10843,10845],{"id":10844},"des-plans-manquants-nempêchent-pas-automatiquement-la-visite","Des plans manquants n'empêchent pas automatiquement la visite",[17,10847,10848],{},"Si le schéma unifilaire ou le plan de position manque lors de la visite de vente, l'organisme peut néanmoins contrôler l'installation. Leur absence est consignée comme infraction. Ce n'est pas la même chose que déclarer la visite ou l'acte impossible.",[17,10850,10851],{},"Des plans actuels restent très utiles pour identifier circuits, protections et points d'utilisation. Ils ne corrigent aucun défaut technique et ne remplacent jamais le rapport.",[12,10853,10855],{"id":10854},"le-dossier-ne-se-limite-pas-à-trois-pièces","Le dossier ne se limite pas à trois pièces",[17,10857,10858],{},"Le chapitre 9.1.2 décrit un dossier plus large que le trio “rapport, unifilaire, position”. Selon l'installation et son histoire, il comprend notamment :",[711,10860,10861,10866,10871,10874,10877,10880],{},[714,10862,5038,10863,10865],{},[221,10864,1248],{}," à jour ;",[714,10867,5038,10868,10870],{},[221,10869,2003],{}," des éléments électriques ;",[714,10872,10873],{},"les rapports de contrôle de conformité, visites et revisites ;",[714,10875,10876],{},"les documents relatifs aux modifications et extensions ;",[714,10878,10879],{},"les instructions et données techniques nécessaires à l'utilisation et à l'entretien sûrs ;",[714,10881,10882],{},"pour une production décentralisée, les plans et informations supplémentaires concernant production et protections.",[17,10884,10885],{},"Un installateur ne délivre pas un “certificat de conformité RGIE” autonome qui remplacerait le rapport de l'organisme agréé. Factures, fiches et dossier d'exécution peuvent être pertinents, mais le résultat officiel de la visite vient de l'organisme agréé.",[12,10887,10889],{"id":10888},"les-schémas-doivent-refléter-létat-réel","Les schémas doivent refléter l'état réel",[17,10891,10892],{},"L'unifilaire présente tableaux, protections, circuits, conducteurs et repérages requis. Le plan de position localise les éléments. Un plan de construction ou un ancien schéma ne suffit plus si l'installation a été transformée.",[17,10894,10895],{},"Avant la visite :",[5034,10897,10898,10901,10904,10907,10910,10913],{},[714,10899,10900],{},"repérer clairement chaque tableau et départ ;",[714,10902,10903],{},"relever types et calibres des DDR et protections contre les surintensités ;",[714,10905,10906],{},"vérifier nature et section des conducteurs, sans les deviner ;",[714,10908,10909],{},"localiser prises, éclairages, commandes et appareils fixes ;",[714,10911,10912],{},"relever prise de terre, barrette et équipotentialité ;",[714,10914,10915],{},"confronter plans, étiquettes et réalisation.",[17,10917,10918],{},"Un trajet de câble invisible ne doit pas être présenté comme une certitude. Toute ambiguïté importante doit être vérifiée techniquement.",[12,10920,10922],{"id":10921},"rapport-négatif-le-délai-de-18-mois-a-un-périmètre-précis","Rapport négatif : le délai de 18 mois a un périmètre précis",[17,10924,10925,10926,10929],{},"Dans la procédure spéciale de 8.4.2, une installation non conforme n'interdit pas automatiquement la vente. Le rapport négatif et les obligations passent à l'acquéreur. Celui-ci dispose alors de ",[221,10927,10928],{},"18 mois à compter de la date de l'acte"," pour remédier aux infractions et demander une revisite au même organisme agréé.",[17,10931,10932],{},"Ce délai ne vaut pas pour tout rapport négatif. Dans d'autres contextes de contrôle, le délai de revisite est souvent de douze mois. Il faut lire le motif, les constatations et l'échéance explicitement indiqués dans le rapport. Une échéance administrative n'autorise jamais à maintenir un danger immédiat.",[12,10934,10936],{"id":10935},"valable-25-ans-nest-pas-une-règle-universelle","“Valable 25 ans” n'est pas une règle universelle",[17,10938,10939],{},"Certaines installations domestiques doivent subir une visite périodique au plus tard tous les 25 ans. Cela ne transforme pas tout rapport en passeport valable 25 ans pour toute vente. Extension, modification importante, renforcement, rapport négatif ou décalage entre rapport et état réel peuvent déclencher une autre visite. Vérifiez adresse, périmètre, résultat et travaux ultérieurs.",[12,10941,10943],{"id":10942},"prix-et-délais-demander-des-données-réelles","Prix et délais : demander des données réelles",[17,10945,10946],{},"Le RGIE ne fixe ni tarif de dessin ou de contrôle, ni délai général de rendez-vous, ni réduction automatique du prix de vente. Ils varient selon l'installation, l'organisme, la région et les travaux. Demandez des offres et coordonnez le calendrier avec notaire, organisme et, si nécessaire, électricien. Il serait trompeur de promettre une préparation en quelques heures ou un délai uniforme.",[12,10948,10950],{"id":10949},"répartir-correctement-les-rôles","Répartir correctement les rôles",[17,10952,10953],{},"Lorsque 8.4.2 s'applique, le vendeur fait réaliser la visite et remet le rapport. L'organisme agréé contrôle et décrit les infractions ; il ne conçoit pas automatiquement les travaux. Le notaire traite les informations dans le transfert mais ne remplace aucune expertise technique. En présence d'un rapport de vente négatif, l'acquéreur reprend l'obligation réglementée de correction et de revisite.",[17,10955,10956],{},"Un électricien peut relever l'existant, corriger et mettre les plans à jour, mais il ne délivre pas le rapport officiel. Le propriétaire conserve le dossier et y trace les modifications. Si l'auteur ou le périmètre d'un document est incertain, il faut le clarifier avant la remise.",[12,10958,10960],{"id":10959},"travaux-entre-visite-et-acte","Travaux entre visite et acte",[17,10962,10963],{},"Le contrôle décrit un état à une date donnée. Ajouter des circuits, renforcer le raccordement, installer une borne ou du photovoltaïque, ou remplacer des protections après la visite peut rendre le rapport incomplet pour l'état vendu. Un schéma actualisé ne démontre pas à lui seul que les travaux ont été contrôlés. Consignez date, étendue et exécutant, puis demandez à l'organisme si une nouvelle visite s'impose.",[17,10965,10966],{},"Pour la production décentralisée, un symbole PV sur l'unifilaire ne suffit pas : raccordement, protections et données techniques utiles font partie de la documentation. Une référence d'onduleur absente ou différente ne doit jamais être complétée par supposition.",[12,10968,10970],{"id":10969},"lire-le-rapport-au-delà-de-la-conclusion","Lire le rapport au-delà de la conclusion",[17,10972,10973],{},"Vérifiez identification, raccordement, périmètre contrôlé, valeurs mesurées, dérogations, remarques et date de revisite. Une remarque n'est pas nécessairement une infraction ; inversement, quelques mesures favorables ne renversent pas une conclusion négative. Toute contradiction entre rapport et installation doit être soumise à l'organisme agréé.",[12,10975,10977],{"id":10976},"existant-rénovation-partielle-et-rénovation-complète","Existant, rénovation partielle et rénovation complète",[17,10979,10980],{},"La partie 8 prévoit des dérogations pour certaines parties anciennes, pas une dispense globale pour tout le bâtiment. Si une pièce ou un tableau seulement est modifié, le périmètre des travaux doit pouvoir être démontré. La partie modifiée peut relever des prescriptions actuelles tandis que l'existant inchangé conserve des règles spécifiques. L'exception de visite préalable en cas de rénovation complète ne s'applique que si ses conditions et la mention exigée dans l'acte sont réunies ; elle ne préjuge jamais de la conformité après travaux.",[17,10982,10983],{},"Conservez les versions successives des plans avec leur date au lieu d'effacer l'historique. Reliez chaque rapport à la version contrôlée et notez les travaux postérieurs. Photos, factures et fiches peuvent compléter cette traçabilité, sans remplacer les plans et rapports prescrits.",[5686,10985,10987],{"id":10986},"appartement-et-parties-communes","Appartement et parties communes",[17,10989,10990],{},"Dans une copropriété, installation privative et parties communes peuvent dépendre de propriétaires, tableaux et contrôles différents. Ne représentez comme partie vendue que ce qui a réellement été relevé, et identifiez clairement les alimentations communes. Le dossier de copropriété n'est pas automatiquement celui de l'unité : notaire et organisme agréé déterminent les pièces utiles au transfert concret.",[12,10992,10994],{"id":10993},"liste-de-remise","Liste de remise",[711,10996,10998,11004,11010,11016,11022,11028,11034],{"className":10997},[6084],[714,10999,11001,11003],{"className":11000},[6088],[6090,11002],{"disabled":1234,"type":6092}," Motif de contrôle et exception éventuelle confirmés",[714,11005,11007,11009],{"className":11006},[6088],[6090,11008],{"disabled":1234,"type":6092}," Rapports existants rattachés à la bonne installation",[714,11011,11013,11015],{"className":11012},[6088],[6090,11014],{"disabled":1234,"type":6092}," Schéma unifilaire et plan de position conformes à l'état réel",[714,11017,11019,11021],{"className":11018},[6088],[6090,11020],{"disabled":1234,"type":6092}," Modifications, production décentralisée et fiches utiles ajoutées",[714,11023,11025,11027],{"className":11024},[6088],[6090,11026],{"disabled":1234,"type":6092}," Tableaux et circuits lisiblement repérés",[714,11029,11031,11033],{"className":11030},[6088],[6090,11032],{"disabled":1234,"type":6092}," Infractions, échéances et responsabilités comprises",[714,11035,11037,11039],{"className":11036},[6088],[6090,11038],{"disabled":1234,"type":6092}," Originaux remis à l'acquéreur et copie conservée",[12,11041,11043],{"id":11042},"auditer-les-pièces-avant-mission-et-remise","Auditer les pièces avant mission et remise",[17,11045,11046],{},"Avant le contrôle, classez toutes les pièces disponibles par adresse, compteur ou EAN, tableau et date. Vérifiez que le dessin le plus récent concerne bien l'unité vendue. Un rapport de parties communes, une ancienne numérotation de rue ou un plan antérieur à la rénovation ne devient pas silencieusement la preuve actuelle. Listez les contradictions et demandez au notaire et à l'organisme agréé quelles pièces s'appliquent au transfert concret.",[17,11048,11049],{},"Après la visite, ne recopiez pas seulement la conclusion dans une liste de tâches. Relevez chaque constat avec son emplacement, le repère de plan concerné, la partie responsable et le délai mentionné au rapport. Faites réaliser et documenter les corrections par une personne compétente. Devis ou facture ne prouvent pas le résultat installé ; plans actualisés et éventuel contrôle de suivi complètent la chaîne de preuve.",[17,11051,1759,11052,11057,11058,11063],{},[203,11053,11056],{"href":11054,"rel":11055},"https:\u002F\u002Feconomie.fgov.be\u002Ffr\u002Fthemes\u002Fenergie\u002Fsources-et-vecteurs-denergie\u002Felectricite\u002Fsecurite-et-controle-des\u002Flivre-1-du-reglement-general",[5373],"FAQ officielle du SPF Économie pour les notaires et l'immobilier"," explique contrôle de vente, contenu du dossier et rôles. La ",[203,11059,11062],{"href":11060,"rel":11061},"https:\u002F\u002Feconomie.fgov.be\u002Ffr\u002Fthemes\u002Fenergie\u002Fsources-et-vecteurs-denergie\u002Felectricite\u002Fsecurite-et-controle-des\u002Fcontrole-des-installations\u002Ftypes-de-controle-des",[5373],"présentation officielle des types de contrôle"," précise le motif. Lisez-les avec le Livre 1 actuel et le rapport concret.",[12,11065,11067],{"id":11066},"rôle-exact-de-planelec","Rôle exact de PlanElec",[17,11069,11070],{},"PlanElec permet de relever l'installation dans l'éditeur, d'exporter schéma unifilaire et plan de position en PDF et de lancer un auto-contrôle indicatif. Il structure la préparation, mais ne produit aucun rapport officiel, ne déclare pas l'installation conforme au RGIE et ne remplace ni mesure ni visite d'un organisme agréé.",[12,11072,11074],{"id":11073},"guides-associés","Guides associés",[711,11076,11077,11082,11087],{},[714,11078,11079],{},[203,11080,11081],{"href":6216},"Préparer le contrôle électrique en Belgique",[714,11083,11084],{},[203,11085,11086],{"href":10042},"Que vérifie le contrôleur lors de la visite ?",[714,11088,11089],{},[203,11090,5401],{"href":3283},[17,11092,11093],{},[203,11094,11095],{"href":1204},"Ouvrir PlanElec pour préparer schéma, plan de position et auto-contrôle indicatif →",[17,11097,11098],{},[60,11099,11100],{},"Base réglementaire : RGIE Livre 1 V06, principalement partie 8, section 8.4.2 et chapitre 9.1. Le texte officiel, le rapport concret et l'analyse du notaire et de l'organisme agréé restent déterminants.",{"title":1212,"searchDepth":1213,"depth":1213,"links":11102},[11103,11104,11105,11106,11107,11108,11109,11110,11111,11112,11113,11114,11117,11118,11119,11120],{"id":10792,"depth":1213,"text":10793},{"id":10810,"depth":1213,"text":10811},{"id":10844,"depth":1213,"text":10845},{"id":10854,"depth":1213,"text":10855},{"id":10888,"depth":1213,"text":10889},{"id":10921,"depth":1213,"text":10922},{"id":10935,"depth":1213,"text":10936},{"id":10942,"depth":1213,"text":10943},{"id":10949,"depth":1213,"text":10950},{"id":10959,"depth":1213,"text":10960},{"id":10969,"depth":1213,"text":10970},{"id":10976,"depth":1213,"text":10977,"children":11115},[11116],{"id":10986,"depth":5848,"text":10987},{"id":10993,"depth":1213,"text":10994},{"id":11042,"depth":1213,"text":11043},{"id":11066,"depth":1213,"text":11067},{"id":11073,"depth":1213,"text":11074},"2026-06-29","Quand la visite de vente s’applique-t-elle, que contient le dossier RGIE et dans quel cas le délai de 18 mois court-il ? Guide précis selon le Livre 1 V06.",{},"\u002Fblog\u002Fproperty-sale-electrical-dossier.fr",{"title":10786,"description":11122},"dossier-electrique-vente-immobiliere","blog\u002Fproperty-sale-electrical-dossier.fr",[1243,1242,11129,7392,11130,1248,2003,11131,1249,10095],"vente immobilière","rapport de contrôle","notaire","NbDLTPWQMvQ1crpdad-dclkwR_8IZi-ROtELGS88FLs",{"id":11134,"title":11135,"articleId":11136,"body":11137,"category":1228,"date":11806,"description":11807,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":11808,"navigation":1234,"path":11809,"publishDate":11806,"readTime":8416,"refreshInterval":1237,"seo":11810,"slug":11811,"stem":11812,"tags":11813,"__hash__":11821},"blog\u002Fblog\u002Ftop-10-arei-violations.fr.md","10 points de contrôle RGIE importants : Identifier, éviter et corriger","top-10-arei-violations",{"type":9,"value":11138,"toc":11743},[11139,11142,11144,11148,11154,11158,11161,11165,11172,11176,11187,11191,11194,11196,11200,11205,11208,11217,11220,11223,11226,11240,11244,11247,11249,11253,11258,11261,11264,11267,11270,11273,11290,11293,11296,11298,11302,11307,11310,11317,11320,11323,11326,11337,11340,11343,11345,11349,11354,11357,11360,11363,11366,11369,11383,11386,11389,11391,11395,11400,11403,11406,11409,11416,11419,11486,11497,11500,11503,11505,11509,11514,11517,11524,11527,11530,11533,11544,11547,11550,11552,11556,11561,11564,11571,11574,11577,11580,11591,11594,11597,11599,11603,11608,11611,11614,11617,11620,11623,11634,11637,11640,11642,11646,11651,11654,11657,11660,11663,11666,11677,11680,11683,11685,11689,11701,11703,11708,11733],[17,11140,11141],{},"Ces dix points forment une liste professionnelle, pas un classement statistique. Aucune source nationale officielle n'étaye un taux de refus ou cet ordre. Le rapport concret reste déterminant.",[7849,11143],{},[12,11145,11147],{"id":11146},"_1-différentiel-absent-ou-inadéquat","1. Différentiel absent ou inadéquat",[17,11149,11150,11153],{},[221,11151,11152],{},"Article RGIE :"," Art. 4.2.4.3 (RCD principal) \u002F Art. 4.2.4.3b (obligation différentiel 30 mA par groupe)",[5686,11155,11157],{"id":11156},"description","Description",[17,11159,11160],{},"Un point de contrôle important est un différentiel absent, inadapté ou mal dimensionné. Pour les installations domestiques, le RGIE place notamment les circuits de prises, l'éclairage, les lieux avec baignoire ou douche, les lave-linge, sèche-linge et lave-vaisselle derrière un différentiel à haute ou très haute sensibilité. Cela n'établit aucun classement national de fréquence.",[5686,11162,11164],{"id":11163},"pourquoi-cest-un-problème","Pourquoi c'est un problème",[17,11166,11167,11168,11171],{},"Le différentiel est la protection des personnes la plus importante dans une installation électrique. Il détecte les courants de fuite (par ex. quand du courant traverse le corps humain) et coupe en quelques millisecondes. Sans différentiel, il y a ",[221,11169,11170],{},"danger de mort"," en cas de défaut d'isolement.",[5686,11173,11175],{"id":11174},"comment-corriger","Comment corriger",[711,11177,11178,11181,11184],{},[714,11179,11180],{},"Déduire le type de différentiel et la combinaison de protections du spectre de courant de défaut, du schéma de terre, des preuves fabricant et du chapitre spécial applicable. Pour une borne, évaluer ensemble le différentiel individuel du circuit AC et la protection contre les défauts DC lisses ; pour un onduleur, vérifier la variante exacte.",[714,11182,11183],{},"Maximum 8 circuits terminaux par RCD 30 mA (RGIE Art. 4.2.4.3b)",[714,11185,11186],{},"À l'origine, au moins un différentiel de maximum 300 mA est requis ; les différentiels domestiques sont au moins de type A. Une exécution temporisée ou sélective dépend de la coordination du projet, pas d'une règle universelle imposant le type A-S.",[5686,11188,11190],{"id":11189},"étendue-propre-au-projet","Étendue propre au projet",[17,11192,11193],{},"Appareil, pôles, place, câblage et mesures déterminent l'offre.",[7849,11195],{},[12,11197,11199],{"id":11198},"_2-plans-électriques-absents-ou-obsolètes","2. Plans électriques absents ou obsolètes",[17,11201,11202,11204],{},[221,11203,11152],{}," Art. 9.1.2 Nr. 1 (schéma unifilaire), Art. 9.1.2 Nr. 2 (plan de situation)",[5686,11206,11157],{"id":11207},"description-1",[17,11209,11210,11211,11213,11214,11216],{},"Le RGIE exige un ",[221,11212,1248],{}," et un ",[221,11215,8422],{}," à jour pour toute installation électrique. Souvent, ces plans manquent complètement ou ne reflètent pas l'état actuel de l'installation — par exemple parce que des circuits ont été ajoutés ou modifiés après la construction.",[5686,11218,11164],{"id":11219},"pourquoi-cest-un-problème-1",[17,11221,11222],{},"Sans plans actuels, ni le contrôleur ni un électricien ne peut évaluer l'installation en toute sécurité. En cas d'urgence (incendie, accident), il manque la documentation indiquant quel interrupteur alimente quelle zone.",[5686,11224,11175],{"id":11225},"comment-corriger-1",[711,11227,11228,11231,11234],{},[714,11229,11230],{},"Établir ou mettre à jour le schéma unifilaire et le plan de situation",[714,11232,11233],{},"Documenter tous les circuits, disjoncteurs, RCD et consommateurs",[714,11235,11236,11237],{},"Les plans doivent montrer l'",[221,11238,11239],{},"état réel actuel",[5686,11241,11243],{"id":11242},"coûts-typiques","Coûts typiques",[17,11245,11246],{},"Données vérifiées et identification des circuits déterminent le travail ; le logiciel ne remplace pas le relevé.",[7849,11248],{},[12,11250,11252],{"id":11251},"_3-mise-à-la-terre-défectueuse","3. Mise à la terre défectueuse",[17,11254,11255,11257],{},[221,11256,11152],{}," Art. 4.2.3",[5686,11259,11157],{"id":11260},"description-2",[17,11262,11263],{},"La mise à la terre fait partie du concept de protection. Une résistance mesurée supérieure à 30 ohms n'équivaut pas automatiquement à une terre absente selon l'Art. 4.2.4.3b ; elle déclenche des exigences supplémentaires de protection différentielle. Il y a notamment défaut lorsque la terre est absente ou endommagée, ou lorsque l'arrangement de protection correspondant à la mesure n'est pas réalisé. Les connexions desserrées et conducteurs corrodés doivent aussi être évalués.",[5686,11265,11164],{"id":11266},"pourquoi-cest-un-problème-2",[17,11268,11269],{},"Sans mise à la terre fonctionnelle, des boîtiers métalliques peuvent être sous tension sans que le différentiel ne se déclenche. Cela crée un piège mortel invisible.",[5686,11271,11175],{"id":11272},"comment-corriger-2",[711,11274,11275,11278,11281,11284,11287],{},[714,11276,11277],{},"Faire mesurer la résistance de terre",[714,11279,11280],{},"Au-delà de 30 ohms, vérifier l'arrangement complémentaire du Livre 1 : au moins deux différentiels à haute ou très haute sensibilité, au plus seize prises simples ou multiples par différentiel concerné et la protection complémentaire des autres circuits visés",[714,11282,11283],{},"Décider professionnellement s'il faut améliorer la prise de terre, adapter les protections ou réaliser les deux",[714,11285,11286],{},"Vérifier toutes les connexions de terre et les resserrer si nécessaire",[714,11288,11289],{},"Contrôler la corrosion du conducteur de terre",[5686,11291,11243],{"id":11292},"coûts-typiques-1",[17,11294,11295],{},"Mesure, installation, sol et travaux déterminent la solution.",[7849,11297],{},[12,11299,11301],{"id":11300},"_4-interrupteur-principal-absent","4. Interrupteur principal absent",[17,11303,11304,11306],{},[221,11305,11152],{}," Art. 5.3.5.1b (interrupteur-sectionneur principal)",[5686,11308,11157],{"id":11309},"description-3",[17,11311,11312,11313,11316],{},"Toute installation électrique doit disposer d'un ",[221,11314,11315],{},"interrupteur principal omnipolaire"," permettant de mettre toute l'installation hors tension. L'interrupteur principal doit être d'au moins 40A (pour les habitations standard).",[5686,11318,11164],{"id":11319},"pourquoi-cest-un-problème-3",[17,11321,11322],{},"En cas d'urgence, toute l'installation doit pouvoir être coupée d'un seul geste — par exemple en cas d'incendie, d'inondation ou d'accident. L'absence d'interrupteur principal peut coûter des secondes vitales.",[5686,11324,11175],{"id":11325},"comment-corriger-3",[711,11327,11328,11331,11334],{},[714,11329,11330],{},"Installer un interrupteur principal omnipolaire ≥40A avant le premier RCD",[714,11332,11333],{},"L'interrupteur doit être facilement accessible (tableau de distribution)",[714,11335,11336],{},"Pour installation triphasée : utiliser un interrupteur principal 4 pôles",[5686,11338,11243],{"id":11339},"coûts-typiques-2",[17,11341,11342],{},"Calibre, pôles, place et adaptation sont spécifiques au projet.",[7849,11344],{},[12,11346,11348],{"id":11347},"_5-zones-salle-de-bains-non-respectées","5. Zones salle de bains non respectées",[17,11350,11351,11353],{},[221,11352,11152],{}," Art. 7.1",[5686,11355,11157],{"id":11356},"description-4",[17,11358,11359],{},"Le RGIE actuel définit les volumes 0, 1 et, pour certaines configurations avec baignoire, 2. Il ne faut pas transformer le volume 3 conservé dans certaines dispositions transitoires d'anciennes installations en volume général d'un nouveau projet. Les limites dépendent de la géométrie réelle de la baignoire ou de la douche.",[5686,11361,11164],{"id":11362},"pourquoi-cest-un-problème-4",[17,11364,11365],{},"L'eau et l'électricité forment une combinaison mortelle. Les zones de salle de bains garantissent que les appareils électriques maintiennent une distance de sécurité suffisante par rapport aux sources d'eau.",[5686,11367,11175],{"id":11368},"comment-corriger-4",[711,11370,11371,11374,11377,11380],{},[714,11372,11373],{},"Déplacer prises et interrupteurs hors des zones 0 et 1 (minimum 60 cm de la baignoire\u002Fdouche)",[714,11375,11376],{},"En zone 2 : uniquement des appareils IPX4 (protection contre les éclaboussures)",[714,11378,11379],{},"Protéger tous les circuits salle de bains par un RCD 30 mA",[714,11381,11382],{},"Pas de boîtes de dérivation en zone 0 ou 1",[5686,11384,11243],{"id":11385},"coûts-typiques-3",[17,11387,11388],{},"Position, chemin, finitions et matériel déterminent les travaux.",[7849,11390],{},[12,11392,11394],{"id":11393},"_6-section-de-câble-trop-faible-pour-le-disjoncteur","6. Section de câble trop faible pour le disjoncteur",[17,11396,11397,11399],{},[221,11398,11152],{}," Art. 4.4.1 (protection contre les surintensités) \u002F Art. 5.2.1.2 (choix des canalisations électriques)",[5686,11401,11157],{"id":11402},"description-5",[17,11404,11405],{},"Le disjoncteur (MCB) doit correspondre à la section du câble. Une combinaison fréquente : disjoncteur 20A sur un câble de 1.5 mm² (qui ne supporte que 16A). Le disjoncteur ne protège alors plus le câble contre la surcharge.",[5686,11407,11164],{"id":11408},"pourquoi-cest-un-problème-5",[17,11410,11411,11412,11415],{},"Quand un câble transporte plus de courant qu'il ne peut supporter, il s'échauffe et peut provoquer des incendies. Le disjoncteur doit ",[221,11413,11414],{},"toujours être inférieur ou égal"," à la capacité du câble.",[5686,11417,11175],{"id":11418},"comment-corriger-5",[21,11420,11421,11434],{},[24,11422,11423],{},[27,11424,11425,11428,11431],{},[30,11426,11427],{},"Section de câble",[30,11429,11430],{},"Fusible max. (gG)",[30,11432,11433],{},"Disjoncteur max.",[43,11435,11436,11447,11457,11466,11476],{},[27,11437,11438,11441,11444],{},[48,11439,11440],{},"1.5 mm²",[48,11442,11443],{},"10A",[48,11445,11446],{},"16A",[27,11448,11449,11452,11454],{},[48,11450,11451],{},"2.5 mm²",[48,11453,11446],{},[48,11455,11456],{},"20A",[27,11458,11459,11461,11463],{},[48,11460,3609],{},[48,11462,11456],{},[48,11464,11465],{},"25A",[27,11467,11468,11470,11473],{},[48,11469,3619],{},[48,11471,11472],{},"32A",[48,11474,11475],{},"40A",[27,11477,11478,11480,11483],{},[48,11479,3630],{},[48,11481,11482],{},"50A",[48,11484,11485],{},"63A",[711,11487,11488,11494],{},[714,11489,11490,11491],{},"Réduire le disjoncteur à la valeur correcte ",[221,11492,11493],{},"ou",[714,11495,11496],{},"Remplacer le câble par une section plus grande",[5686,11498,11243],{"id":11499},"coûts-typiques-4",[17,11501,11502],{},"Réduire la protection et remplacer le câble sont deux solutions différentes.",[7849,11504],{},[12,11506,11508],{"id":11507},"_7-trop-de-circuits-par-différentiel","7. Trop de circuits par différentiel",[17,11510,11511,11513],{},[221,11512,11152],{}," Art. 4.2.4.3b (max. 8 circuits terminaux par RCD 30 mA) ; Art. 5.3.5.2b (max. 8 prises par circuit terminal)",[5686,11515,11157],{"id":11516},"description-6",[17,11518,11519,11520,11523],{},"Le RGIE limite le nombre de circuits par RCD 30 mA à ",[221,11521,11522],{},"maximum 8",". Dans les installations anciennes, tous les circuits sont souvent raccordés à un seul différentiel.",[5686,11525,11164],{"id":11526},"pourquoi-cest-un-problème-6",[17,11528,11529],{},"Avec trop de circuits sur un même RCD, la probabilité de déclenchements intempestifs augmente (par addition des courants de fuite). De plus, en cas de défaut, toute l'habitation est privée de courant — pas seulement la zone concernée.",[5686,11531,11175],{"id":11532},"comment-corriger-6",[711,11534,11535,11538,11541],{},[714,11536,11537],{},"Installer des RCD 30 mA supplémentaires",[714,11539,11540],{},"Répartir les circuits de manière logique (par ex. par étage ou fonction)",[714,11542,11543],{},"Maximum 8 circuits par RCD 30 mA",[5686,11545,11243],{"id":11546},"coûts-typiques-5",[17,11548,11549],{},"Place, répartition, calibre et mesures appartiennent à l'offre.",[7849,11551],{},[12,11553,11555],{"id":11554},"_8-étiquetage-manquant-des-circuits","8. Étiquetage manquant des circuits",[17,11557,11558,11560],{},[221,11559,11152],{}," Art. 3.1.3.1 (identification des circuits)",[5686,11562,11157],{"id":11563},"description-7",[17,11565,11566,11567,11570],{},"Tous les disjoncteurs et RCD dans le tableau de distribution doivent être ",[221,11568,11569],{},"clairement étiquetés",". L'étiquetage doit indiquer quelle pièce ou quel appareil est alimenté par le circuit concerné.",[5686,11572,11164],{"id":11573},"pourquoi-cest-un-problème-7",[17,11575,11576],{},"Sans étiquetage, le bon circuit ne peut pas être rapidement coupé en cas d'urgence. Pour les travaux de maintenance également, une attribution claire est indispensable.",[5686,11578,11175],{"id":11579},"comment-corriger-7",[711,11581,11582,11585,11588],{},[714,11583,11584],{},"Apposer des étiquettes lisibles sur tous les disjoncteurs",[714,11586,11587],{},"Dénomination par pièce et\u002Fou fonction (par ex. \"Cuisine prises\", \"Salle de bains éclairage\")",[714,11589,11590],{},"L'étiquetage doit correspondre au schéma unifilaire",[5686,11592,11243],{"id":11593},"coûts-typiques-6",[17,11595,11596],{},"L'étiquette est simple ; identifier sûrement un circuit inconnu peut exiger un professionnel.",[7849,11598],{},[12,11600,11602],{"id":11601},"_9-câbles-sans-protection","9. Câbles sans protection",[17,11604,11605,11607],{},[221,11606,11152],{}," Art. 5.2.2 (modes de pose) \u002F Art. 5.2.1.5 (résistance mécanique)",[5686,11609,11157],{"id":11610},"description-8",[17,11612,11613],{},"Les câbles électriques doivent être posés dans des tubes de protection (gaines), des goulottes ou des saignées murales. Des câbles apparents sans protection mécanique — par exemple en saillie ou en vrac dans la cave — constituent une infraction.",[5686,11615,11164],{"id":11616},"pourquoi-cest-un-problème-8",[17,11618,11619],{},"Les câbles non protégés peuvent être endommagés mécaniquement (clou, vis, rongeurs). Un isolant de câble endommagé peut provoquer des courts-circuits et des incendies.",[5686,11621,11175],{"id":11622},"comment-corriger-8",[711,11624,11625,11628,11631],{},[714,11626,11627],{},"Placer les câbles apparents dans des goulottes (tubes de protection)",[714,11629,11630],{},"Pour le montage en saillie : utiliser des goulottes adaptées",[714,11632,11633],{},"Étanchéifier les traversées de murs avec des manchons coupe-feu",[5686,11635,11243],{"id":11636},"coûts-typiques-7",[17,11638,11639],{},"Canalisation, environnement, protection et bâtiment définissent la solution.",[7849,11641],{},[12,11643,11645],{"id":11644},"_10-parafoudre-spd-absent-pour-nouvelle-installation","10. Parafoudre (SPD) absent pour nouvelle installation",[17,11647,11648,11650],{},[221,11649,11152],{}," Art. 4.5.1",[5686,11652,11157],{"id":11653},"description-9",[17,11655,11656],{},"L'Art. 4.5.1 prescrit de manière générale que les personnes et les biens doivent être protégés contre les effets nuisibles des surtensions — selon les règles de l'art. En pratique, un SPD (parafoudre) est exigé pour les nouvelles installations et les extensions substantielles. Pour les installations existantes, il est recommandé mais pas expressément imposé.",[5686,11658,11164],{"id":11659},"pourquoi-cest-un-problème-9",[17,11661,11662],{},"Les surtensions dues à la foudre ou aux perturbations du réseau peuvent détruire l'électronique sensible. Un SPD dévie les surtensions en toute sécurité vers la terre et protège les appareils connectés.",[5686,11664,11175],{"id":11665},"comment-corriger-9",[711,11667,11668,11671,11674],{},[714,11669,11670],{},"Installer un SPD Type 2 dans le tableau de distribution (après l'interrupteur principal, avant les RCD)",[714,11672,11673],{},"En cas d'installation paratonnerre : ajouter un SPD Type 1",[714,11675,11676],{},"Vérifier régulièrement l'indicateur d'état du SPD (vert = OK)",[5686,11678,11243],{"id":11679},"coûts-typiques-8",[17,11681,11682],{},"Choix du SPD, coordination, raccordement et tableau sont spécifiques.",[7849,11684],{},[12,11686,11688],{"id":11687},"conclusion-lauto-contrôle-comme-aide-à-la-planification","Conclusion : L'auto-contrôle comme aide à la planification",[17,11690,11691,11692,207,11696,11700],{},"PlanElec signale certains problèmes pris en charge. Il ne détecte pas les défauts physiques et l'auto-contrôle reste partiel. Sources : ",[203,11693,11695],{"href":5371,"rel":11694},[5373],"RGIE Livre 1 V06",[203,11697,11699],{"href":6185,"rel":11698},[5373],"contrôle domestique officiel",", sans classement de fréquence.",[7849,11702],{},[17,11704,11705],{},[221,11706,11707],{},"Articles connexes :",[711,11709,11710,11716,11722,11727],{},[714,11711,11712],{},[203,11713,11715],{"href":11714},"\u002Ffr\u002Fblog\u002Fcontrole-electrique-refuse","Contrôle électrique refusé — que faire ?",[714,11717,11718],{},[203,11719,11721],{"href":11720},"\u002Ffr\u002Fblog\u002Fdifferentiel-30ma","Différentiel 30 mA : quand est-il obligatoire ?",[714,11723,11724],{},[203,11725,11726],{"href":1579},"Section de câble et disjoncteur : la bonne combinaison",[714,11728,11729],{},[203,11730,11732],{"href":11731},"\u002Ffr\u002Fblog\u002Fcables-salle-de-bains-zones-rgie","Câbles salle de bains et zones RGIE",[17,11734,11735,11738,11739],{},[221,11736,11737],{},"Structurez votre planification avec PlanElec et utilisez l'auto-contrôle pour préparer la vérification professionnelle et le contrôle officiel."," ",[203,11740,11742],{"href":8394,"rel":11741},[5373],"Commencer maintenant →",{"title":1212,"searchDepth":1213,"depth":1213,"links":11744},[11745,11751,11757,11763,11769,11775,11781,11787,11793,11799,11805],{"id":11146,"depth":1213,"text":11147,"children":11746},[11747,11748,11749,11750],{"id":11156,"depth":5848,"text":11157},{"id":11163,"depth":5848,"text":11164},{"id":11174,"depth":5848,"text":11175},{"id":11189,"depth":5848,"text":11190},{"id":11198,"depth":1213,"text":11199,"children":11752},[11753,11754,11755,11756],{"id":11207,"depth":5848,"text":11157},{"id":11219,"depth":5848,"text":11164},{"id":11225,"depth":5848,"text":11175},{"id":11242,"depth":5848,"text":11243},{"id":11251,"depth":1213,"text":11252,"children":11758},[11759,11760,11761,11762],{"id":11260,"depth":5848,"text":11157},{"id":11266,"depth":5848,"text":11164},{"id":11272,"depth":5848,"text":11175},{"id":11292,"depth":5848,"text":11243},{"id":11300,"depth":1213,"text":11301,"children":11764},[11765,11766,11767,11768],{"id":11309,"depth":5848,"text":11157},{"id":11319,"depth":5848,"text":11164},{"id":11325,"depth":5848,"text":11175},{"id":11339,"depth":5848,"text":11243},{"id":11347,"depth":1213,"text":11348,"children":11770},[11771,11772,11773,11774],{"id":11356,"depth":5848,"text":11157},{"id":11362,"depth":5848,"text":11164},{"id":11368,"depth":5848,"text":11175},{"id":11385,"depth":5848,"text":11243},{"id":11393,"depth":1213,"text":11394,"children":11776},[11777,11778,11779,11780],{"id":11402,"depth":5848,"text":11157},{"id":11408,"depth":5848,"text":11164},{"id":11418,"depth":5848,"text":11175},{"id":11499,"depth":5848,"text":11243},{"id":11507,"depth":1213,"text":11508,"children":11782},[11783,11784,11785,11786],{"id":11516,"depth":5848,"text":11157},{"id":11526,"depth":5848,"text":11164},{"id":11532,"depth":5848,"text":11175},{"id":11546,"depth":5848,"text":11243},{"id":11554,"depth":1213,"text":11555,"children":11788},[11789,11790,11791,11792],{"id":11563,"depth":5848,"text":11157},{"id":11573,"depth":5848,"text":11164},{"id":11579,"depth":5848,"text":11175},{"id":11593,"depth":5848,"text":11243},{"id":11601,"depth":1213,"text":11602,"children":11794},[11795,11796,11797,11798],{"id":11610,"depth":5848,"text":11157},{"id":11616,"depth":5848,"text":11164},{"id":11622,"depth":5848,"text":11175},{"id":11636,"depth":5848,"text":11243},{"id":11644,"depth":1213,"text":11645,"children":11800},[11801,11802,11803,11804],{"id":11653,"depth":5848,"text":11157},{"id":11659,"depth":5848,"text":11164},{"id":11665,"depth":5848,"text":11175},{"id":11679,"depth":5848,"text":11243},{"id":11687,"depth":1213,"text":11688},"2026-06-20","Dix contrôles récurrents pour les installations domestiques belges, sans classement, taux de refus ni promesse de coût non étayés.",{},"\u002Fblog\u002Ftop-10-arei-violations.fr",{"title":11135,"description":11807},"10-infractions-rgie-frequentes","blog\u002Ftop-10-arei-violations.fr",[8832,11814,11815,11816,11817,11818,11819,11820],"infractions","controle-electrique","controle","differentiel","mise-a-la-terre","belgique","defauts","EyYmtaObKX3yKclo6JgAwWPQWj-Ivamc7KDwkbEW6JM",{"id":11823,"title":11824,"articleId":11825,"body":11826,"category":1228,"date":12259,"description":12260,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":12261,"navigation":1234,"path":12262,"publishDate":12259,"readTime":12263,"refreshInterval":1237,"seo":12264,"slug":12265,"stem":12266,"tags":12267,"__hash__":12270},"blog\u002Fblog\u002Finspection-failed-what-now.fr.md","Contrôle électrique refusé — que faire ? Guide étape par étape après un contrôle négatif","inspection-failed-what-now",{"type":9,"value":11827,"toc":12233},[11828,11834,11837,11841,11848,11852,11897,11900,11904,11908,11915,11919,11922,11926,11933,11937,11940,11972,11975,11979,11983,11986,11997,12001,12004,12008,12014,12028,12032,12039,12043,12046,12050,12053,12057,12060,12077,12081,12084,12087,12104,12107,12111,12114,12117,12121,12124,12127,12131,12134,12138,12161,12164,12168,12174,12200,12203,12205,12209,12225],[17,11829,11830,11833],{},[221,11831,11832],{},"Procédez avec méthode."," Les sources officielles utilisées ici ne publient pas de pourcentage national fiable de contrôles négatifs. Un rapport négatif ne permet pas non plus de conclure, en général, qu'il s'agit uniquement de documents ou d'un danger immédiat. Chaque constat du rapport fait foi.",[17,11835,11836],{},"Dans ce guide, vous découvrirez ce qu'il faut faire après un contrôle négatif, quels sont les codes d'infraction et comment vous préparer au recontrôle.",[12,11838,11840],{"id":11839},"que-se-passe-t-il-après-un-contrôle-négatif","Que se passe-t-il après un contrôle négatif ?",[17,11842,11843,11844,11847],{},"Après le contrôle, vous recevez un ",[221,11845,11846],{},"rapport détaillé"," de l'organisme agréé. Il indique les infractions, les parties concernées et la conclusion.",[5686,11849,11851],{"id":11850},"lire-les-codes-avec-la-légende-du-rapport","Lire les codes avec la légende du rapport",[21,11853,11854,11864],{},[24,11855,11856],{},[27,11857,11858,11861],{},[30,11859,11860],{},"Champ du rapport",[30,11862,11863],{},"Ce qu'il permet de déterminer",[43,11865,11866,11874,11881,11889],{},[27,11867,11868,11871],{},[48,11869,11870],{},"Code ou catégorie",[48,11872,11873],{},"Sens donné uniquement par la légende de ce rapport",[27,11875,11876,11878],{},[48,11877,426],{},[48,11879,11880],{},"Prescription et fonction de protection contestées",[27,11882,11883,11886],{},[48,11884,11885],{},"Lieu ou circuit",[48,11887,11888],{},"Partie de l'installation concernée sans ambiguïté",[27,11890,11891,11894],{},[48,11892,11893],{},"Conclusion et délai",[48,11895,11896],{},"Conséquence du type de contrôle réel, pas d'un code générique",[17,11898,11899],{},"Les codes et classes de priorité peuvent varier selon l'organisme et son modèle. Ne déduisez pas un délai belge universel de « C1 », « C2 » ou « C3 ». Utilisez la légende du rapport et demandez au rédacteur de préciser la référence, le circuit et la preuve attendue. Tout danger immédiat signalé est prioritaire, quel que soit le code abrégé.",[12,11901,11903],{"id":11902},"délais-selon-la-situation","Délais selon la situation",[5686,11905,11907],{"id":11906},"lors-dune-vente-immobilière","Lors d'une vente immobilière",[17,11909,11910,11911,11914],{},"Pour le contrôle « vente » concerné d'une ancienne habitation, l'acheteur dispose en principe de ",[221,11912,11913],{},"18 mois à compter de l'acte authentique",", et non d'une simple offre privée, pour remettre en ordre et organiser une nouvelle visite.",[5686,11916,11918],{"id":11917},"pour-une-nouvelle-installation","Pour une nouvelle installation",[17,11920,11921],{},"Pour une installation neuve ou une modification importante, la partie en infraction ne peut pas être mise en usage. Il faut d'abord corriger puis faire réaliser un nouveau contrôle de conformité. Toute procédure de raccordement se vérifie séparément auprès du gestionnaire concerné.",[5686,11923,11925],{"id":11924},"lors-du-contrôle-périodique","Lors du contrôle périodique",[17,11927,11928,11929,11932],{},"Après un contrôle périodique négatif, l'information fédérale prévoit une visite complémentaire par ",[221,11930,11931],{},"le même organisme dans les douze mois",". Vérifiez toujours le type de contrôle et les instructions du rapport.",[12,11934,11936],{"id":11935},"dix-domaines-à-vérifier-sans-classement-statistique","Dix domaines à vérifier, sans classement statistique",[17,11938,11939],{},"Utilisez ces domaines comme aide de lecture, sans prétendre à une fréquence nationale ni à un verdict automatique :",[5034,11941,11942,11945,11948,11951,11954,11957,11960,11963,11966,11969],{},[714,11943,11944],{},"protection différentielle adaptée à chaque circuit et récepteur ;",[714,11946,11947],{},"cohérence du schéma unifilaire, du plan de situation et des étiquettes ;",[714,11949,11950],{},"terre, liaisons équipotentielles et coupure automatique étayées par des mesures ;",[714,11952,11953],{},"identification claire des circuits et protections ;",[714,11955,11956],{},"choix et protection mécanique des canalisations selon leur mode de pose ;",[714,11958,11959],{},"règles des emplacements spéciaux, dont la géométrie réelle de la salle de bains ;",[714,11961,11962],{},"commande et sectionnement principaux adaptés à l'installation ;",[714,11964,11965],{},"coordination des conducteurs, conditions de pose et protections contre les surintensités ;",[714,11967,11968],{},"évaluation explicite de la protection contre les surtensions ;",[714,11970,11971],{},"séparation entre constats RGIE et obligations régionales de logement, comme les détecteurs de fumée.",[17,11973,11974],{},"Le constat exact du contrôleur et le Livre 1 en vigueur déterminent la correction. Une liste ne remplace ni diagnostic, ni mesure, ni rapport.",[12,11976,11978],{"id":11977},"étape-par-étape-après-le-contrôle-négatif","Étape par étape : après le contrôle négatif",[5686,11980,11982],{"id":11981},"étape-1-lire-attentivement-le-rapport","Étape 1 : Lire attentivement le rapport",[17,11984,11985],{},"Examinez chaque infraction individuellement. Notez :",[711,11987,11988,11991,11994],{},[714,11989,11990],{},"Quelle catégorie et quelle légende le rapport emploie-t-il ?",[714,11992,11993],{},"Où se situe exactement le problème (pièce, circuit) ?",[714,11995,11996],{},"Que reproche-t-on exactement ?",[5686,11998,12000],{"id":11999},"étape-2-établir-les-priorités","Étape 2 : Établir les priorités",[17,12002,12003],{},"Commencez par tout constat qualifié de danger immédiat, de motif de coupure ou d'obstacle à la mise en usage. Ordonnez ensuite les autres travaux par dépendance : cause et concept de protection, réalisation, mesure puis documentation.",[5686,12005,12007],{"id":12006},"étape-3-professionnel-ou-soi-même","Étape 3 : Professionnel ou soi-même ?",[17,12009,12010,12011,1096],{},"Vous pouvez classer le rapport, rassembler les documents et comparer les plans au matériel visible. La possibilité de corriger soi-même dépend du travail et des compétences. Les interventions dans le tableau, sur les protections, la terre ou les canalisations fixes relèvent d'un ",[221,12012,12013],{},"professionnel",[711,12015,12016,12019,12022,12025],{},[714,12017,12018],{},"Ajouter ou remplacer le différentiel",[714,12020,12021],{},"Améliorer la mise à la terre",[714,12023,12024],{},"Placer les câbles dans des tubes de protection",[714,12026,12027],{},"Installer l'interrupteur principal",[5686,12029,12031],{"id":12030},"étape-4-mettre-à-jour-les-plans","Étape 4 : Mettre à jour les plans",[17,12033,12034,12035,12038],{},"Le schéma unifilaire et le plan de situation doivent refléter ",[221,12036,12037],{},"l'état actuel",". N'inventez ni section de conducteur ni calibre. Faites déterminer les caractéristiques inconnues avant l'export ou marquez-les comme ouvertes.",[5686,12040,12042],{"id":12041},"étape-5-planifier-le-recontrôle","Étape 5 : Planifier le recontrôle",[17,12044,12045],{},"L'organisme compétent dépend de la procédure. La visite complémentaire après contrôle périodique négatif revient au même organisme. Après le contrôle « vente » négatif concerné, l'acheteur peut en principe choisir un organisme agréé et la nouvelle visite porte sur l'ensemble de l'installation. Confirmez la portée avant de réserver.",[12,12047,12049],{"id":12048},"budgéter-sans-fausse-précision","Budgéter sans fausse précision",[17,12051,12052],{},"Tarifs et réparations dépendent de la procédure, de l'organisme, du déplacement, des tableaux, des mesures et du défaut réel. Demandez le tarif actuel directement. Un devis de correction devrait séparer diagnostic, matériel, travail, mesures, mise à jour des plans et nouvelle visite. Une fourchette en ligne ne représente pas une canalisation cachée ou une reconstruction de tableau.",[12,12054,12056],{"id":12055},"constituer-la-preuve-pour-la-nouvelle-visite","Constituer la preuve pour la nouvelle visite",[17,12058,12059],{},"Tenez une ligne par constat : texte du rapport, circuit, action, responsable, date d'achèvement et preuve. Les photos complètent le dossier sans remplacer les mesures. Actualisez les plans après la réalisation, puis rapprochez encore repères et étiquettes.",[17,12061,1759,12062,12066,12067,12071,12072,212],{},[203,12063,12065],{"href":11060,"rel":12064},[5373],"page officielle des types de contrôles domestiques"," explique conséquences et délais. La ",[203,12068,12070],{"href":11054,"rel":12069},[5373],"FAQ fédérale sur la vente"," détaille les dix-huit mois et le choix de l'organisme. Consultez aussi la ",[203,12073,12076],{"href":12074,"rel":12075},"https:\u002F\u002Feconomie.fgov.be\u002Ffr\u002Fthemes\u002Fenergie\u002Fsources-et-vecteurs-denergie\u002Felectricite\u002Fsecurite-et-controle-des\u002Forganismes-de-controle-agrees",[5373],"liste officielle des organismes agréés",[12,12078,12080],{"id":12079},"transformer-chaque-constat-en-action-vérifiable","Transformer chaque constat en action vérifiable",[17,12082,12083],{},"Le rapport décrit souvent un résultat et non sa cause technique. Un isolement insuffisant peut venir d'un conducteur endommagé, d'humidité, d'un appareil raccordé ou de plusieurs causes. « Plan non conforme à l'installation » peut désigner une prise absente du dessin comme un mauvais ordre de protections. Ne commandez donc pas immédiatement une pièce : déterminez la cause et la portée.",[17,12085,12086],{},"Pour chaque constat, posez cinq questions :",[5034,12088,12089,12092,12095,12098,12101],{},[714,12090,12091],{},"quelle partie a effectivement été contrôlée ?",[714,12093,12094],{},"quelle règle ou fonction de protection est concernée ?",[714,12096,12097],{},"quel diagnostic ou quelle mesure confirme la cause ?",[714,12099,12100],{},"quelle correction élimine la cause plutôt que son apparence ?",[714,12102,12103],{},"quelle preuve permettra à l'organisme de vérifier la correction terminée ?",[17,12105,12106],{},"Des constats peuvent dépendre les uns des autres. Une modification de tableau change schéma unifilaire, étiquettes, protections et parfois mesures. Une intervention sur la terre doit précéder les plans finaux et nouvelles mesures. Visez un état final cohérent plutôt qu'une série d'états intermédiaires contradictoires.",[12,12108,12110],{"id":12109},"séparer-défaut-documentaire-et-défaut-physique","Séparer défaut documentaire et défaut physique",[17,12112,12113],{},"Un plan manquant ne se corrige pas en dessinant des hypothèses. Relevez d'abord l'installation ; l'ouverture et la mesure sont réservées à une personne compétente et équipée. Reliez ensuite chaque symbole au circuit réel et vérifiez que tableau, schéma unifilaire et plan de situation utilisent le même repère.",[17,12115,12116],{},"Un défaut physique ne disparaît pas avec un meilleur dessin. Si une protection est inadéquate, la terre insuffisante ou un câble exposé, l'installation doit être corrigée puis, si nécessaire, mesurée. Le plan est mis à jour après la réalisation. Cette séquence évite de présenter des documents neufs devant un danger inchangé.",[12,12118,12120],{"id":12119},"cas-particulier-de-la-vente","Cas particulier de la vente",[17,12122,12123],{},"Après un contrôle « vente » négatif, conservez ensemble rapport, acte authentique et dossier. Les dix-huit mois partent de l'acte authentique. L'acheteur communique son identité et la date à l'organisme initial. Si un autre organisme agréé est choisi pour la nouvelle visite, l'explication fédérale prévoit que celui-ci informe le premier.",[17,12125,12126],{},"Le délai n'autorise pas à ignorer un danger manifeste. Faites évaluer rapidement les parties incertaines et mettez-les hors service si nécessaire. Une revente, une rénovation totale ou une démolition pendant ce délai peut modifier la procédure : consultez la FAQ fédérale et le contexte notarial concret.",[12,12128,12130],{"id":12129},"maîtriser-les-changements-avant-la-nouvelle-visite","Maîtriser les changements avant la nouvelle visite",[17,12132,12133],{},"Après correction, figez un état documenté : plans datés, repérage du tableau, mesures et photos des travaux qui seront ensuite cachés. Comparez toute modification ultérieure à cet état et actualisez le dossier si nécessaire. Un câble ajouté en apparence anodin peut sinon rompre la cohérence établie par l'électricien et le dessinateur. Demandez aux utilisateurs d'éviter raccordements provisoires et transformations autonomes avant le rendez-vous. Si un changement est indispensable, transmettez au professionnel responsable le rapport, les plans actuels et une description précise des nouveaux travaux. La chaîne de preuve reste ainsi continue et le contrôleur n'examine pas, sans le savoir, une installation différente de celle préparée.",[12,12135,12137],{"id":12136},"dernière-vérification-avant-le-rendez-vous","Dernière vérification avant le rendez-vous",[711,12139,12140,12143,12146,12149,12152,12155,12158],{},[714,12141,12142],{},"Chaque constat correspond à une action terminée.",[714,12144,12145],{},"Les corrections nécessitant des mesures disposent de résultats.",[714,12147,12148],{},"Les repères concordent entre tableau et deux plans.",[714,12150,12151],{},"Le matériel ajouté ou retiré figure au plan de situation.",[714,12153,12154],{},"Calibres et câbles correspondent au schéma réalisé.",[714,12156,12157],{},"L'organisme et le type de contrôle sont confirmés.",[714,12159,12160],{},"Rapport, plans, code EAN et notices utiles sont prêts.",[17,12162,12163],{},"Cette préparation ne promet pas un rapport positif. Elle évite qu'une réparation terminée soit impossible à vérifier à cause de documents contradictoires.",[12,12165,12167],{"id":12166},"comment-planelec-vous-aide","Comment PlanElec vous aide",[17,12169,12170,12171,1096],{},"PlanElec peut détecter bon nombre des causes de refus les plus fréquentes ",[221,12172,12173],{},"AVANT le contrôle",[711,12175,12176,12182,12188,12194],{},[714,12177,12178,12181],{},[221,12179,12180],{},"La validation"," signale des données prises en charge sur les différentiels et protections",[714,12183,12184,12187],{},[221,12185,12186],{},"Le schéma unifilaire"," représente de façon cohérente la topologie saisie",[714,12189,12190,12193],{},[221,12191,12192],{},"Le plan de situation"," utilise la bibliothèque belge prise en charge",[714,12195,12196,12199],{},[221,12197,12198],{},"L'étiquetage"," de tous les circuits est automatiquement documenté dans le schéma",[17,12201,12202],{},"L'autocontrôle n'est pas une attestation, n'effectue aucune mesure et ne garantit pas un résultat positif. Il aide à produire un dossier cohérent pour l'examen professionnel.",[7849,12204],{},[17,12206,12207],{},[221,12208,11707],{},[711,12210,12211,12217,12221],{},[714,12212,12213],{},[203,12214,12216],{"href":12215},"\u002Ffr\u002Fblog\u002F10-infractions-rgie-frequentes","Les 10 infractions RGIE les plus fréquentes",[714,12218,12219],{},[203,12220,11721],{"href":11720},[714,12222,12223],{},[203,12224,11726],{"href":1579},[17,12226,12227,11738,12230],{},[221,12228,12229],{},"Préparez vos plans électriques avec PlanElec et utilisez l'auto-contrôle comme aide avant la vérification professionnelle et le contrôle officiel.",[203,12231,11742],{"href":8394,"rel":12232},[5373],{"title":1212,"searchDepth":1213,"depth":1213,"links":12234},[12235,12238,12243,12244,12251,12252,12253,12254,12255,12256,12257,12258],{"id":11839,"depth":1213,"text":11840,"children":12236},[12237],{"id":11850,"depth":5848,"text":11851},{"id":11902,"depth":1213,"text":11903,"children":12239},[12240,12241,12242],{"id":11906,"depth":5848,"text":11907},{"id":11917,"depth":5848,"text":11918},{"id":11924,"depth":5848,"text":11925},{"id":11935,"depth":1213,"text":11936},{"id":11977,"depth":1213,"text":11978,"children":12245},[12246,12247,12248,12249,12250],{"id":11981,"depth":5848,"text":11982},{"id":11999,"depth":5848,"text":12000},{"id":12006,"depth":5848,"text":12007},{"id":12030,"depth":5848,"text":12031},{"id":12041,"depth":5848,"text":12042},{"id":12048,"depth":1213,"text":12049},{"id":12055,"depth":1213,"text":12056},{"id":12079,"depth":1213,"text":12080},{"id":12109,"depth":1213,"text":12110},{"id":12119,"depth":1213,"text":12120},{"id":12129,"depth":1213,"text":12130},{"id":12136,"depth":1213,"text":12137},{"id":12166,"depth":1213,"text":12167},"2026-06-16","Votre contrôle est négatif ? Apprenez à lire le rapport, déterminer le délai applicable, planifier des corrections sûres et préparer la nouvelle visite.",{},"\u002Fblog\u002Finspection-failed-what-now.fr","6 min",{"title":11824,"description":12260},"controle-electrique-refuse","blog\u002Finspection-failed-what-now.fr",[11816,11815,12268,11814,12269,8832,11819],"refuse","recontrole","LiLl3zQch0mbSuxpoAr0wXlFDlKXeVajF73_5Z0KsjM",{"id":12272,"title":12273,"articleId":12274,"body":12275,"category":10248,"date":12523,"description":12524,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":12525,"navigation":1234,"path":12526,"publishDate":12523,"readTime":10253,"refreshInterval":1237,"seo":12527,"slug":12528,"stem":12529,"tags":12530,"__hash__":12535},"blog\u002Fblog\u002Fsmart-home-domotica-arei.fr.md","Smart Home et RGIE : Que faut-il savoir sur la domotique ?","smart-home-domotica-arei",{"type":9,"value":12276,"toc":12515},[12277,12283,12287,12293,12296,12310,12314,12321,12328,12332,12428,12432,12435,12439,12446,12463,12467,12470,12483,12485,12489,12507],[17,12278,12279,12282],{},[221,12280,12281],{},"Le RGIE ne réglemente pas directement les appareils Smart Home"," — mais l'installation électrique sous-jacente doit dans tous les cas être conforme au RGIE. Qu'il s'agisse d'interrupteurs WiFi, de prises intelligentes ou de modules DIN-rail : tant que l'installation de base respecte les prescriptions, les solutions Smart Home ne posent aucun problème.",[12,12284,12286],{"id":12285},"quest-ce-qui-est-autorisé","Qu'est-ce qui est autorisé ?",[17,12288,12289,12290,212],{},"Les appareils Smart Home comme les interrupteurs WiFi (Shelly, Sonoff), les prises intelligentes (TP-Link, Hue Smart Plug) ou les ampoules connectées (Philips Hue, IKEA TRADFRI) peuvent être utilisés sans problème — ",[221,12291,12292],{},"tant que l'installation électrique sous-jacente est conforme au RGIE",[17,12294,12295],{},"Cela signifie :",[711,12297,12298,12301,12304,12307],{},[714,12299,12300],{},"Le câblage doit être correctement dimensionné",[714,12302,12303],{},"Les disjoncteurs et différentiels doivent être présents et correctement assignés",[714,12305,12306],{},"L'installation doit être mise à la terre",[714,12308,12309],{},"Les modules Smart Home dans l'installation fixe doivent porter le marquage CE et être employés selon la destination et les conditions d'installation déclarées par le fabricant",[12,12311,12313],{"id":12312},"modules-smart-din-rail-dans-le-tableau-de-distribution","Modules Smart DIN-rail dans le tableau de distribution",[17,12315,12316,12317,12320],{},"Une catégorie particulière concerne les ",[221,12318,12319],{},"modules Smart DIN-rail"," comme Shelly Pro, Shelly Pro 3EM ou les modules DIN Sonoff. Ceux-ci sont installés directement dans le tableau de distribution sur le rail DIN.",[17,12322,12323,12324,12327],{},"Important : comme ils font partie de l'installation fixe dans le tableau, ",[221,12325,12326],{},"les modules DIN-rail apparaissent dans le schéma unifilaire"," (qui, selon la Section 3.1.2.2.a, doit notamment représenter les dispositifs de protection, les interrupteurs et les appareils fixes ; l'obligation de conserver le schéma au sein du dossier de l'installation découle de l'Art. 9.1.2). Ils doivent y être correctement représentés, tout comme les autres composants du tableau.",[12,12329,12331],{"id":12330},"aperçu-types-smart-home-et-rgie","Aperçu : Types Smart Home et RGIE",[21,12333,12334,12349],{},[24,12335,12336],{},[27,12337,12338,12341,12343,12346],{},[30,12339,12340],{},"Type Smart Home",[30,12342,10622],{},[30,12344,12345],{},"RGIE pertinent ?",[30,12347,12348],{},"Dans le schéma unifilaire ?",[43,12350,12351,12365,12378,12390,12403,12416],{},[27,12352,12353,12356,12359,12362],{},[48,12354,12355],{},"Interrupteur WiFi (Shelly 1, Sonoff)",[48,12357,12358],{},"Derrière interrupteur existant",[48,12360,12361],{},"Non, si installation de base conforme",[48,12363,12364],{},"Non, si aucune modification du câblage. Oui, si le câblage fixe est modifié (par ex. neutre tiré vers l'interrupteur)",[27,12366,12367,12370,12373,12376],{},[48,12368,12369],{},"Prise intelligente (plug-in)",[48,12371,12372],{},"Dans prise existante",[48,12374,12375],{},"Non",[48,12377,12375],{},[27,12379,12380,12383,12386,12388],{},[48,12381,12382],{},"Ampoule connectée (Hue, TRADFRI)",[48,12384,12385],{},"Dans douille existante",[48,12387,12375],{},[48,12389,12375],{},[27,12391,12392,12395,12398,12401],{},[48,12393,12394],{},"Module DIN-rail (Shelly Pro)",[48,12396,12397],{},"Tableau de distribution",[48,12399,12400],{},"Oui — installation fixe",[48,12402,8064],{},[27,12404,12405,12408,12411,12414],{},[48,12406,12407],{},"Thermostat intelligent (Nest, tado)",[48,12409,12410],{},"Montage mural",[48,12412,12413],{},"Non, si correctement câblé",[48,12415,12375],{},[27,12417,12418,12421,12424,12426],{},[48,12419,12420],{},"Serrure connectée",[48,12422,12423],{},"Cadre de porte",[48,12425,12375],{},[48,12427,12375],{},[12,12429,12431],{"id":12430},"définir-commande-coupure-et-sectionnement","Définir commande, coupure et sectionnement",[17,12433,12434],{},"N'en déduisez pas qu'un interrupteur mural classique est universellement obligatoire pour chaque fonction connectée. La fonction et les règles applicables à la commande, coupure, séparation, urgence et maintenance sont déterminantes. Une application ou le cloud n'est pas un dispositif de sectionnement sauf conception explicite du produit et du circuit. Respectez la notice et faites concevoir le câblage fixe professionnellement.",[12,12436,12438],{"id":12437},"lors-du-contrôle-électrique","Lors du contrôle électrique",[17,12440,12441,12442,12445],{},"Lors du contrôle électrique, l'organisme de contrôle vérifie l'",[221,12443,12444],{},"installation électrique",", pas la logique Smart Home. Cela signifie :",[711,12447,12448,12451,12454,12460],{},[714,12449,12450],{},"Le câblage, les disjoncteurs et la mise à la terre sont vérifiés",[714,12452,12453],{},"Les modules DIN-rail doivent figurer dans le schéma",[714,12455,12456,12457],{},"L'application Smart Home ou les règles d'automatisation ne sont ",[221,12458,12459],{},"pas contrôlées",[714,12461,12462],{},"Les interrupteurs WiFi derrière le mur ne sont généralement pas contestés si l'installation de base est conforme",[12,12464,12466],{"id":12465},"documenter-les-composants-pris-en-charge-avec-planelec","Documenter les composants pris en charge avec PlanElec",[17,12468,12469],{},"PlanElec peut documenter les composants fixes pris en charge et leurs relations électriques. Si un actionneur précis n'est pas modélisé, consignez-le au dossier au lieu de choisir un autre article. L'autocontrôle n'évalue ni logique domotique, cybersécurité, disponibilité radio ni toutes les notices.",[17,12471,12472,12473,207,12477,12482],{},"Sources officielles : ",[203,12474,12476],{"href":5371,"rel":12475},[5373],"SPF Économie — Livre 1 V06",[203,12478,12481],{"href":12479,"rel":12480},"https:\u002F\u002Fsingle-market-economy.ec.europa.eu\u002Fsingle-market\u002Fce-marking_en",[5373],"Commission européenne — marquage CE",". Le CE est une déclaration du fabricant selon la législation applicable, pas une approbation tierce de l'installation belge.",[7849,12484],{},[17,12486,12487],{},[221,12488,11707],{},[711,12490,12491,12497,12501],{},[714,12492,12493],{},[203,12494,12496],{"href":12495},"\u002Ffr\u002Fblog\u002Fcircuits-dedies","Circuits dédiés : quels appareils nécessitent leur propre circuit ?",[714,12498,12499],{},[203,12500,12216],{"href":12215},[714,12502,12503],{},[203,12504,12506],{"href":12505},"\u002Ffr\u002Fblog\u002Freglementation-rgie-2026","Réglementation RGIE 2026 : qu'est-ce qui a changé ?",[17,12508,12509,11738,12512],{},[221,12510,12511],{},"Documentez les composants pris en charge et faites vérifier l'installation fixe.",[203,12513,7862],{"href":8394,"rel":12514},[5373],{"title":1212,"searchDepth":1213,"depth":1213,"links":12516},[12517,12518,12519,12520,12521,12522],{"id":12285,"depth":1213,"text":12286},{"id":12312,"depth":1213,"text":12313},{"id":12330,"depth":1213,"text":12331},{"id":12430,"depth":1213,"text":12431},{"id":12437,"depth":1213,"text":12438},{"id":12465,"depth":1213,"text":12466},"2026-06-09","Une installation Smart Home doit-elle être conforme au RGIE ? Oui — l'installation électrique sous-jacente doit respecter les prescriptions. Découvrez ce qui est autorisé et les points d'attention.",{},"\u002Fblog\u002Fsmart-home-domotica-arei.fr",{"title":12273,"description":12524},"domotique-rgie","blog\u002Fsmart-home-domotica-arei.fr",[12531,12532,8832,12533,12534,9647,11816],"smart-home","domotique","shelly","din-rail","u-lMR-KJD7F86Xfnj7Gs8hFueaPLIpihTS5ZvR2fxgI",{"id":12537,"title":12538,"articleId":12539,"body":12540,"category":1228,"date":12908,"description":12909,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":12910,"navigation":1234,"path":12911,"publishDate":12908,"readTime":4995,"refreshInterval":1237,"seo":12912,"slug":12913,"stem":12914,"tags":12915,"__hash__":12920},"blog\u002Fblog\u002Fhome-battery-arei.fr.md","Batterie domestique et RGIE : Intégrer correctement un stockage batterie dans l'installation électrique","home-battery-arei",{"type":9,"value":12541,"toc":12882},[12542,12545,12549,12552,12555,12559,12563,12566,12570,12573,12577,12583,12587,12590,12594,12597,12600,12603,12623,12626,12629,12646,12650,12653,12667,12671,12678,12682,12685,12699,12702,12705,12708,12742,12746,12749,12754,12759,12762,12766,12769,12782,12786,12789,12793,12796,12800,12824,12828,12831,12834,12838,12841,12845,12848,12851,12854,12856,12860,12874],[17,12543,12544],{},"Une batterie déplace l'énergie dans le temps, mais ne se conçoit pas à partir de sa seule capacité. Couplage AC ou DC, onduleur, fonctionnement parallèle, secours, protections, fabricant et déclaration régionale déterminent le projet. Ce guide propose donc un parcours documenté, sans promesse de conformité ni de rentabilité.",[12,12546,12548],{"id":12547},"pourquoi-une-batterie-domestique","Pourquoi une batterie domestique ?",[17,12550,12551],{},"Une batterie peut stocker un excédent puis le restituer. La réduction du prélèvement ou de la facture dépend des profils mesurés, de la capacité utile, du rendement, de la commande, du tarif, du vieillissement et du mode d'exploitation. Sans séries temporelles et modèle tarifaire daté, aucune économie ni durée d'amortissement fixe n'est étayée.",[17,12553,12554],{},"Le RGIE ne comporte pas de chapitre propre pour le stockage par batterie domestique — ce sont les règles générales qui s'appliquent (protection contre les chocs électriques, protection contre les surintensités, séparation\u002Fcoupure de sécurité). Le chapitre dédié aux batteries 7.103 (batteries d'accumulateurs industrielles) exclut explicitement les installations domestiques. Lorsque la batterie est couplée à une installation PV, l'Art. 7.112 (installations photovoltaïques domestiques à basse tension ≤ 10 kVA) s'applique à la partie PV ; la batterie elle-même n'en relève pas.",[12,12556,12558],{"id":12557},"exigences-rgie-pour-les-batteries-domestiques","Exigences RGIE pour les batteries domestiques",[5686,12560,12562],{"id":12561},"raccordement-ac-protection-et-conducteurs","Raccordement AC, protection et conducteurs",[17,12564,12565],{},"L'onduleur batterie ou hybride est une source dans la conception. Circuit, protection contre les surintensités, section, type de différentiel et pouvoir de coupure dépendent des caractéristiques, du schéma de terre, de la pose, de la notice et du RGIE. « Toujours 20 A sur 2,5 mm² » ou « triphasé signifie toujours type B » sont des raccourcis injustifiés. Une surveillance DC intégrée ne compte que si les documents du modèle et les règles l'autorisent.",[5686,12567,12569],{"id":12568},"interrupteur-de-séparation-point-de-coupure","Interrupteur de séparation (point de coupure)",[17,12571,12572],{},"Le projet exige un concept de sectionnement traçable. Les pôles, fonctions intégrées et sectionneurs supplémentaires dépendent de la topologie, des preuves du fabricant et des prescriptions applicables. Le schéma montre les dispositifs réels ; les dessiner ne prouve pas leur aptitude.",[5686,12574,12576],{"id":12575},"protection-contre-les-surtensions-spd","Protection contre les surtensions (SPD)",[17,12578,4930,12579,12582],{},[221,12580,12581],{},"parafoudre (SPD)"," est recommandé côté AC. L'Art. 4.5.1 formule le principe général que les personnes et les biens doivent être protégés contre les surtensions, mais ne prescrit pas de type SPD spécifique. Côté DC, un SPD est également conseillé, surtout en cas de câblage extérieur.",[5686,12584,12586],{"id":12585},"ventilation-pour-batteries-lithium","Ventilation pour batteries lithium",[17,12588,12589],{},"Emplacement, température, distances, ventilation et conditions d'incendie suivent la technologie, la notice et l'analyse de risques du projet. Une limite universelle de 35 °C ou une chimie unique pour tous les produits serait inexacte. Conservez type, limites et instructions dans le dossier.",[12,12591,12593],{"id":12592},"intégration-dans-le-schéma-unifilaire","Intégration dans le schéma unifilaire",[17,12595,12596],{},"Le schéma unifilaire doit représenter correctement la batterie domestique. L'intégration comprend deux côtés :",[5686,12598,10722],{"id":12599},"côté-dc",[17,12601,12602],{},"Le côté courant continu montre le trajet du pack batterie via le système de gestion de batterie (BMS) jusqu'à l'onduleur :",[711,12604,12605,12620],{},[714,12606,12607,12610,12611,12610,12614,12610,12617],{},[221,12608,12609],{},"Batterie"," → ",[221,12612,12613],{},"BMS",[221,12615,12616],{},"Interrupteur-sectionneur DC",[221,12618,12619],{},"Onduleur hybride",[714,12621,12622],{},"Pour les systèmes couplés AC : Batterie → onduleur batterie dédié → raccordement AC",[5686,12624,10716],{"id":12625},"côté-ac",[17,12627,12628],{},"Le côté courant alternatif montre l'intégration dans le réseau domestique :",[711,12630,12631,12643],{},[714,12632,12633,12610,12635,12610,12638,12610,12641],{},[221,12634,12619],{},[221,12636,12637],{},"Interrupteur de séparation AC",[221,12639,12640],{},"MCB",[221,12642,12397],{},[714,12644,12645],{},"Le raccordement se fait typiquement après l'interrupteur principal, mais avant les RCD individuels des circuits",[5686,12647,12649],{"id":12648},"représentation-dans-le-schéma","Représentation dans le schéma",[17,12651,12652],{},"Dans le schéma unifilaire, la batterie domestique apparaît comme un départ propre, similaire à l'installation PV. Les symboles comprennent :",[711,12654,12655,12658,12661,12664],{},[714,12656,12657],{},"Symbole de batterie (selon IEC 60617)",[714,12659,12660],{},"Symbole d'onduleur",[714,12662,12663],{},"Interrupteur de séparation",[714,12665,12666],{},"MCB et RCD associés",[12,12668,12670],{"id":12669},"fonction-de-secours-backup","Fonction de secours \u002F Backup",[17,12672,12673,12674,12677],{},"De nombreuses batteries domestiques modernes offrent une ",[221,12675,12676],{},"fonction de secours"," (backup). En cas de coupure du réseau, la batterie continue d'alimenter des circuits sélectionnés.",[5686,12679,12681],{"id":12680},"dispositif-de-commutation","Dispositif de commutation",[17,12683,12684],{},"Une fonction de secours exige un concept documenté de commutation et d'îlotage. Selon le système, la fonction peut être interne à l'onduleur ou réalisée par un appareillage externe ; une appellation commerciale ne prouve ni séparation sûre du réseau ni fonctionnement en îlot admissible :",[711,12686,12687,12693],{},[714,12688,12689,12692],{},[221,12690,12691],{},"Commutation automatique (ATS) :"," Un dispositif interne ou externe documenté change de mode dans les conditions approuvées.",[714,12694,12695,12698],{},[221,12696,12697],{},"Commutation manuelle :"," Un commutateur permet la séparation manuelle du réseau et le fonctionnement en mode îlot.",[17,12700,12701],{},"Représentez la fonction de commutation et la limite de la partie secourue sur le schéma unifilaire. Les conducteurs à couper découlent du schéma de terre, du traitement du neutre, des preuves fabricant et des conditions du gestionnaire. Le résultat doit empêcher toute remise sous tension dangereuse du réseau isolé ; « toujours omnipolaire » n'est pas une règle autonome sans cette topologie.",[12,12703,7459],{"id":12704},"déclaration-au-gestionnaire-de-réseau",[17,12706,12707],{},"Déclaration et raccordement sont régionaux et dépendent du mode de fonctionnement. Avant commande et mise en service, vérifiez la procédure actuelle du gestionnaire de l'adresse, en particulier pour un équipement parallèle au réseau ou techniquement capable de l'être :",[711,12709,12710,12716,12722,12730,12736],{},[714,12711,12712,12715],{},[221,12713,12714],{},"Avec installation PV existante :"," Déclaration de modification — l'installation est enregistrée comme PV + batterie",[714,12717,12718,12721],{},[221,12719,12720],{},"Données techniques :"," Capacité (kWh), puissance onduleur (kW), couplage AC ou DC",[714,12723,12724,12727,12728],{},[221,12725,12726],{},"Homologation :"," C10\u002F11 ed. 2.4 et l'homologation C10\u002F26 concernent les unités parallèles au réseau ou techniquement capables de l'être. Vérifiez modèle, variante et firmware avec la ",[203,12729,7697],{"href":7696},[714,12731,12732,12735],{},[221,12733,12734],{},"Documents :"," Actualisez schéma unifilaire et plan de situation selon l'exécution ; confirmez le dossier à transmettre auprès du gestionnaire compétent",[714,12737,12738,12741],{},[221,12739,12740],{},"Contrôle électrique :"," Nature et portée de la modification, avec le Livre 1, déterminent le nouveau contrôle requis",[12,12743,12745],{"id":12744},"séparer-choix-du-matériel-et-économie","Séparer choix du matériel et économie",[17,12747,12748],{},"Comparez les fiches datées et l'entrée Synergrid exacte, pas un classement de marques. Relevez puissances AC, phases, plage de tension, capacité utile, protections, firmware, comportements parallèle\u002Fsecours et conditions d'extension.",[17,12750,12751],{},[4068,12752,12753],{},"effet annuel = prélèvement évité + services valorisés − pertes supplémentaires − coûts courants",[17,12755,12756],{},[4068,12757,12758],{},"durée du scénario = investissement \u002F effet net annuel estimé prudemment",[17,12760,12761],{},"Ce sont des scénarios, pas des prévisions. Utilisez profils mesurés, capacité utile, pertes, limites de puissance, dégradation, garantie et trajectoire tarifaire transparente. Les primes et tarifs réseau sont régionaux et temporels.",[12,12763,12765],{"id":12764},"documenter-les-chemins-dénergie","Documenter les chemins d'énergie",[17,12767,12768],{},"Séparez AC, DC et états de fonctionnement. Pour chaque chemin : source, conversion, protection, sectionnement et destination. En couplage DC, PV et batterie partagent l'onduleur hybride mais gardent leurs limites. En couplage AC, un onduleur batterie séparé injecte côté AC. Aucune puissance de source ne doit disparaître de l'étude du raccordement.",[17,12770,12771,12772,63,12775,9577,12778,12781],{},"Marquez chaque donnée comme ",[221,12773,12774],{},"connue",[221,12776,12777],{},"issue du fabricant",[221,12779,12780],{},"à vérifier"," : puissance et courant par mode, phases, type et pose des câbles, protections, sectionneurs AC\u002FDC, mesures ou limitations, firmware, chemins parallèle et îlot. Un remplacement d'onduleur peut changer protections, puissance, homologation et déclaration sans changer la capacité.",[12,12783,12785],{"id":12784},"le-secours-est-un-projet-distinct","Le secours est un projet distinct",[17,12787,12788],{},"La mention commerciale « backup » ne signifie pas alimentation automatique de tout le logement. Commutation, séparation du réseau, neutre, terre en îlot, charges retenues, démarrages et batterie vide doivent être étudiés. Identifiez sur le plan les circuits secourus et vérifiez qu'aucune réinjection dangereuse vers le réseau coupé n'est possible.",[12,12790,12792],{"id":12791},"dossier-de-contrôle-et-déclaration","Dossier de contrôle et déclaration",[17,12794,12795],{},"Conservez schémas actualisés, fiches, notices, preuve Synergrid de la variante, réglages d'interface, rapport de contrôle et confirmation régionale. Fluvius relie explicitement en Flandre stockage, contrôle RGIE et conditions Synergrid. Wallonie et Bruxelles ont leurs opérateurs et procédures : ne recopiez pas des seuils flamands.",[12,12797,12799],{"id":12798},"sources-primaires-actuelles","Sources primaires actuelles",[711,12801,12802,12809,12816],{},[714,12803,12804,12808],{},[203,12805,12807],{"href":5371,"rel":12806},[5373],"SPF Économie : RGIE Livre 1 version 06",", y compris les modifications DC applicables au 1er avril 2026.",[714,12810,12811,12815],{},[203,12812,12814],{"href":6589,"rel":12813},[5373],"Synergrid : homologation des unités décentralisées",", C10\u002F11 ed.2.4 et C10\u002F26 pour onduleurs batterie et hybrides parallèles ou techniquement capables.",[714,12817,12818,12823],{},[203,12819,12822],{"href":12820,"rel":12821},"https:\u002F\u002Fwww.fluvius.be\u002Fnl\u002Fgroene-energie\u002Fthuisbatterij\u002Fopslagsysteem-aanmelden",[5373],"Fluvius : déclaration d'un stockage",", source régionale flamande.",[12,12825,12827],{"id":12826},"limite-planelec-et-contrôle-avant-exécution","Limite PlanElec et contrôle avant exécution",[17,12829,12830],{},"PlanElec relie aujourd'hui plan, topologie et exports disponibles. Son modèle peut représenter des sources, mais batterie, générateur et V2G ne disposent pas encore d'une chaîne publiée complète palette–inspecteur–rendu–export. Un symbole ou un auto-contrôle sans erreur ne prouve ni couverture complète ni conformité.",[17,12832,12833],{},"Avant travaux : décrire séparément réseau, zéro injection et secours ; relever modèle, firmware et statut Synergrid ; dessiner tous les chemins ; dériver protections du fabricant et du RGIE ; vérifier PV, comptage et raccordement ; confirmer contrôle et déclaration avec l'opérateur de l'adresse ; conserver réglages et documents après mise en service.",[12,12835,12837],{"id":12836},"figer-les-paramètres-de-mise-en-service","Figer les paramètres de mise en service",[17,12839,12840],{},"Ajoutez au dossier une fiche datée avec modèle, variante, firmware, modes réseau et secours, limites de puissance, protections réellement posées et réglages confirmés. Reliez chaque valeur à la plaque signalétique, à la notice ou au procès-verbal concerné. Lors d'une mise à jour logicielle ou d'un remplacement, comparez cette base avant de conclure que l'homologation, la protection et la déclaration restent inchangées.",[12,12842,12844],{"id":12843},"erreurs-de-documentation-à-éviter","Erreurs de documentation à éviter",[17,12846,12847],{},"Ne regroupez pas batterie et onduleur sous un symbole sans caractéristiques. Ne confondez pas versions AC et DC portant un nom commercial proche. Pour le secours, représentez aussi la commutation et la frontière entre partie secourue et partie normale. Vérifiez C10\u002F26 par modèle, variante et firmware, jamais uniquement par marque. Un exemple de disjoncteur ou différentiel fourni pour un autre réseau n'est pas une règle générale. Après un remplacement d'onduleur, mettez à jour schéma, réglages, contrôle et notification selon ce qui a réellement changé.",[17,12849,12850],{},"Pendant la mise en service, consignez les valeurs confirmées plutôt que les valeurs prévues. Comparez les références installées au dossier, vérifiez les étiquettes et remettez au propriétaire les instructions utiles à l'arrêt normal et d'urgence. Une réserve écrite sur une donnée non vérifiée est préférable à une case remplie par supposition. Le dossier devient ainsi une base de maintenance et pas seulement une pièce remise lors du premier contrôle.",[17,12852,12853],{},"Toute extension ultérieure doit reprendre ce même chemin : référence exacte, effet électrique, mise à jour des plans, vérification des conditions du fabricant et décision sur un nouveau contrôle ou une nouvelle notification.",[7849,12855],{},[17,12857,12858],{},[221,12859,11707],{},[711,12861,12862,12866,12870],{},[714,12863,12864],{},[203,12865,12506],{"href":12505},[714,12867,12868],{},[203,12869,12496],{"href":12495},[714,12871,12872],{},[203,12873,11726],{"href":1579},[17,12875,12876,11738,12879],{},[221,12877,12878],{},"Structurez les données connues dans PlanElec et faites vérifier protections, exécution et déclaration.",[203,12880,11742],{"href":8394,"rel":12881},[5373],{"title":1212,"searchDepth":1213,"depth":1213,"links":12883},[12884,12885,12891,12896,12899,12900,12901,12902,12903,12904,12905,12906,12907],{"id":12547,"depth":1213,"text":12548},{"id":12557,"depth":1213,"text":12558,"children":12886},[12887,12888,12889,12890],{"id":12561,"depth":5848,"text":12562},{"id":12568,"depth":5848,"text":12569},{"id":12575,"depth":5848,"text":12576},{"id":12585,"depth":5848,"text":12586},{"id":12592,"depth":1213,"text":12593,"children":12892},[12893,12894,12895],{"id":12599,"depth":5848,"text":10722},{"id":12625,"depth":5848,"text":10716},{"id":12648,"depth":5848,"text":12649},{"id":12669,"depth":1213,"text":12670,"children":12897},[12898],{"id":12680,"depth":5848,"text":12681},{"id":12704,"depth":1213,"text":7459},{"id":12744,"depth":1213,"text":12745},{"id":12764,"depth":1213,"text":12765},{"id":12784,"depth":1213,"text":12785},{"id":12791,"depth":1213,"text":12792},{"id":12798,"depth":1213,"text":12799},{"id":12826,"depth":1213,"text":12827},{"id":12836,"depth":1213,"text":12837},{"id":12843,"depth":1213,"text":12844},"2026-06-02","Comment installer une batterie domestique selon le RGIE ? Ce guide explique les exigences en matière de circuit dédié, interrupteur de séparation, schéma unifilaire et déclaration au gestionnaire de réseau.",{},"\u002Fblog\u002Fhome-battery-arei.fr",{"title":12538,"description":12909},"batterie-domestique-rgie","blog\u002Fhome-battery-arei.fr",[6822,12916,8832,12917,7929,12918,12919],"stockage-energie","photovoltaique","schema-unifilaire","secours","CC06VBb0KL7s-_QmSx3x82OW3CDUMGqtLhq8vCnAFlk",{"id":12922,"title":12923,"articleId":12924,"body":12925,"category":10248,"date":13183,"description":13184,"extension":1231,"lastUpdated":13185,"locale":1232,"meta":13186,"navigation":1234,"path":13187,"publishDate":13183,"readTime":10253,"refreshInterval":1237,"seo":13188,"slug":13189,"stem":13190,"tags":13191,"__hash__":13195},"blog\u002Fblog\u002Fsmoke-detector-mandatory.fr.md","Détecteur de fumée obligatoire en Belgique : que prévoit la loi en Flandre, Wallonie et Bruxelles ?","smoke-detector-mandatory",{"type":9,"value":12926,"toc":13172},[12927,12931,12937,12941,12945,12948,12971,12975,12981,12996,13000,13007,13024,13028,13095,13099,13106,13109,13113,13142,13146,13152,13154,13158,13164],[12928,12929,12923],"h1",{"id":12930},"détecteur-de-fumée-obligatoire-en-belgique-que-prévoit-la-loi-en-flandre-wallonie-et-bruxelles",[17,12932,12933,12936],{},[221,12934,12935],{},"Oui, les détecteurs de fumée sont obligatoires en Belgique"," — mais la législation est régionale. Selon que vous habitez en Flandre, en Wallonie ou à Bruxelles, les exigences en termes de nombre et d'emplacement diffèrent.",[12,12938,12940],{"id":12939},"réglementation-régionale-en-un-coup-doeil","Réglementation régionale en un coup d'oeil",[5686,12942,12944],{"id":12943},"flandre","Flandre",[17,12946,12947],{},"Depuis le 1er janvier 2020, tous les logements en Flandre doivent être équipés de détecteurs de fumée. Les règles :",[711,12949,12950,12955,12961,12968],{},[714,12951,12952],{},[221,12953,12954],{},"Au minimum un détecteur de fumée par étage",[714,12956,12957,12960],{},[221,12958,12959],{},"Dans chaque voie d'évacuation"," (couloir, cage d'escalier) un détecteur doit être installé",[714,12962,12963,12964,12967],{},"Dans les chambres à coucher, l'installation est ",[221,12965,12966],{},"recommandée"," mais pas obligatoire",[714,12969,12970],{},"S'applique à tous les logements locatifs et propriétés",[5686,12972,12974],{"id":12973},"wallonie","Wallonie",[17,12976,12977,12978,1096],{},"La Wallonie a été pionnière avec l'obligation ",[221,12979,12980],{},"depuis 2010",[711,12982,12983,12987,12993],{},[714,12984,12985],{},[221,12986,12954],{},[714,12988,12989,12990],{},"Emplacements obligatoires : ",[221,12991,12992],{},"couloirs et cages d'escalier",[714,12994,12995],{},"En cas de location, le propriétaire doit assurer l'installation",[5686,12997,12999],{"id":12998},"bruxelles","Bruxelles",[17,13001,13002,13003,13006],{},"La Région de Bruxelles-Capitale impose l'obligation ",[221,13004,13005],{},"depuis 2005"," — la plus ancienne réglementation en Belgique :",[711,13008,13009,13014,13021],{},[714,13010,13011],{},[221,13012,13013],{},"Un détecteur de fumée par étage",[714,13015,13016,13017,13020],{},"Obligatoire dans les ",[221,13018,13019],{},"voies d'évacuation"," (couloirs, escaliers)",[714,13022,13023],{},"S'applique à tous les bâtiments résidentiels",[12,13025,13027],{"id":13026},"tableau-récapitulatif","Tableau récapitulatif",[21,13029,13030,13049],{},[24,13031,13032],{},[27,13033,13034,13037,13040,13043,13046],{},[30,13035,13036],{},"Région",[30,13038,13039],{},"Obligatoire depuis",[30,13041,13042],{},"Nombre minimum",[30,13044,13045],{},"Emplacements obligatoires",[30,13047,13048],{},"Norme",[43,13050,13051,13067,13081],{},[27,13052,13053,13055,13058,13061,13064],{},[48,13054,12944],{},[48,13056,13057],{},"2020",[48,13059,13060],{},"1 par étage",[48,13062,13063],{},"Voies d'évacuation (couloirs, escaliers)",[48,13065,13066],{},"NBN EN 14604",[27,13068,13069,13071,13074,13076,13079],{},[48,13070,12974],{},[48,13072,13073],{},"2010",[48,13075,13060],{},[48,13077,13078],{},"Couloirs, cages d'escalier",[48,13080,13066],{},[27,13082,13083,13085,13088,13090,13093],{},[48,13084,12999],{},[48,13086,13087],{},"2005",[48,13089,13060],{},[48,13091,13092],{},"Voies d'évacuation",[48,13094,13066],{},[12,13096,13098],{"id":13097},"lien-avec-le-rgie-détecteurs-de-fumée-et-le-contrôle-électrique","Lien avec le RGIE : Détecteurs de fumée et le contrôle électrique",[17,13100,13101,13102,13105],{},"Point important : ",[221,13103,13104],{},"les détecteurs de fumée ne sont pas directement réglementés par le RGIE."," Le RGIE régit principalement l'installation électrique — câbles, fusibles, mise à la terre, etc. L'Art. 9.1.2 Nr. 2 exige que le dossier de l'installation électrique comprenne un plan de situation ; son contenu prescrit est défini de manière limitative (prises de courant, interrupteurs, points lumineux ainsi qu'appareils ou machines fixes) et ne comprend pas les détecteurs de fumée.",[17,13107,13108],{},"Comme les détecteurs de fumée ne font pas partie de l'installation électrique réglementée par le RGIE, ils ne font pas l'objet du contrôle électrique ; l'absence d'un détecteur de fumée ne constitue pas un défaut RGIE. Certains installateurs ou organismes de contrôle représentent néanmoins les détecteurs de fumée sur le plan de situation à titre informatif, afin de documenter la position de tous les appareils pertinents dans le logement.",[12,13110,13112],{"id":13111},"entretien-et-remplacement","Entretien et remplacement",[711,13114,13115,13121,13127,13133],{},[714,13116,13117,13120],{},[221,13118,13119],{},"Mensuellement :"," Appuyer sur le bouton de test pour vérifier le fonctionnement",[714,13122,13123,13126],{},[221,13124,13125],{},"Annuellement :"," Test approfondi et dépoussiérage",[714,13128,13129,13132],{},[221,13130,13131],{},"Tous les 10 ans :"," Remplacer complètement le détecteur (les capteurs perdent en sensibilité)",[714,13134,13135,13136,13139,13140],{},"Utilisez uniquement des détecteurs avec le ",[221,13137,13138],{},"marquage CE"," et conformes à la norme ",[221,13141,13066],{},[12,13143,13145],{"id":13144},"détecteurs-de-fumée-dans-le-plan-de-situation-avec-planelec","Détecteurs de fumée dans le plan de situation avec PlanElec",[17,13147,13148,13149,13151],{},"Avec PlanElec, vous pouvez dessiner les détecteurs de fumée directement dans le ",[221,13150,8422],{}," de votre logement. Le symbole du détecteur de fumée est affiché correctement selon la norme RGIE, assurant que votre plan est complet lors du contrôle électrique.",[7849,13153],{},[17,13155,13156],{},[221,13157,11707],{},[711,13159,13160],{},[714,13161,13162],{},[203,13163,12506],{"href":12505},[17,13165,13166,11738,13169],{},[221,13167,13168],{},"Créez votre plan électrique conforme au RGIE avec PlanElec — y compris les symboles de détecteur de fumée dans le plan de situation.",[203,13170,11742],{"href":8394,"rel":13171},[5373],{"title":1212,"searchDepth":1213,"depth":1213,"links":13173},[13174,13179,13180,13181,13182],{"id":12939,"depth":1213,"text":12940,"children":13175},[13176,13177,13178],{"id":12943,"depth":5848,"text":12944},{"id":12973,"depth":5848,"text":12974},{"id":12998,"depth":5848,"text":12999},{"id":13026,"depth":1213,"text":13027},{"id":13097,"depth":1213,"text":13098},{"id":13111,"depth":1213,"text":13112},{"id":13144,"depth":1213,"text":13145},"2026-05-28","Les détecteurs de fumée sont-ils obligatoires en Belgique ? Oui — mais les règles varient selon la région. Découvrez ce qui s'applique en Flandre, Wallonie et Bruxelles.","2026-06-05",{},"\u002Fblog\u002Fsmoke-detector-mandatory.fr",{"title":12923,"description":13184},"detecteur-fumee-obligatoire-belgique","blog\u002Fsmoke-detector-mandatory.fr",[13192,13193,11819,12943,12973,12998,13194],"detecteur-fumee","securite-incendie","securite","BKaCFr08o7LztMJFWhHRk7KKbSnjiCpmjFqJYrsyNks",{"id":13197,"title":13198,"articleId":13199,"body":13200,"category":1228,"date":13868,"description":13869,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":13870,"navigation":1234,"path":13871,"publishDate":13868,"readTime":8416,"refreshInterval":1237,"seo":13872,"slug":13873,"stem":13874,"tags":13875,"__hash__":13879},"blog\u002Fblog\u002Fborne-recharge-rgie.fr.md","Installer une borne de recharge selon le RGIE : Le guide complet pour la Belgique","ev-charger-installation-arei",{"type":9,"value":13201,"toc":13834},[13202,13205,13209,13212,13216,13223,13227,13230,13233,13236,13238,13241,13245,13249,13313,13318,13329,13334,13342,13346,13411,13416,13427,13432,13443,13447,13450,13454,13458,13526,13532,13535,13542,13564,13571,13575,13578,13582,13589,13592,13596,13607,13610,13614,13620,13624,13631,13636,13640,13643,13646,13650,13656,13660,13702,13706,13711,13725,13729,13732,13736,13774,13778,13781,13783,13798,13800,13802,13814,13822,13826],[17,13203,13204],{},"L'installation d'une borne de recharge en Belgique relève du chapitre 7.22 du Livre 1 du RGIE. Ce guide explique les principales questions d'étude ; il ne remplace ni la notice du fabricant, ni les conditions du gestionnaire de réseau, ni l'appréciation de l'électricien et de l'organisme agréé.",[12,13206,13208],{"id":13207},"exigences-rgie-pour-borne-de-recharge-art-722","Exigences RGIE pour borne de recharge (Art. 7.22)",[17,13210,13211],{},"Le RGIE pose les exigences de base suivantes pour les installations de bornes de recharge :",[5686,13213,13215],{"id":13214},"circuit-dédié","Circuit dédié",[17,13217,13218,13219,13222],{},"La borne de recharge ",[221,13220,13221],{},"doit"," disposer de son propre circuit dédié. Elle ne peut pas être raccordée à un circuit existant (par ex. prises dans le garage). Ce circuit dédié doit aller directement du coffret de distribution à la borne.",[5686,13224,13226],{"id":13225},"différentiel-protection-différentielle","Différentiel (protection différentielle)",[17,13228,13229],{},"Chaque borne de recharge nécessite son propre différentiel (RCD). Le type de différentiel dépend de la borne (plus de détails ci-dessous).",[5686,13231,13232],{"id":10265},"Disjoncteur",[17,13234,13235],{},"Un disjoncteur (MCB) correctement dimensionné protège le circuit de la borne contre les surcharges et les courts-circuits.",[5686,13237,12576],{"id":12575},[17,13239,13240],{},"L'art. 4.5.1 exige de manière générale la protection contre les surtensions selon les règles de l'art. En pratique, un SPD central est installé dans le coffret de distribution, protégeant tous les circuits y compris celui de la borne de recharge contre les surtensions transitoires causées par la foudre ou les commutations dans le réseau.",[12,13242,13244],{"id":13243},"monophasé-vs-triphasé-quelle-borne","Monophasé vs. triphasé : Quelle borne ?",[5686,13246,13248],{"id":13247},"monophasé-37-kw-ou-74-kw","Monophasé — 3,7 kW ou 7,4 kW",[21,13250,13251,13264],{},[24,13252,13253],{},[27,13254,13255,13258,13261],{},[30,13256,13257],{},"Caractéristique",[30,13259,13260],{},"3,7 kW (16A)",[30,13262,13263],{},"7,4 kW (32A)",[43,13265,13266,13275,13284,13292,13302],{},[27,13267,13268,13270,13273],{},[48,13269,8965],{},[48,13271,13272],{},"Monophasé, 230V",[48,13274,13272],{},[27,13276,13277,13280,13282],{},[48,13278,13279],{},"Intensité",[48,13281,11446],{},[48,13283,11472],{},[27,13285,13286,13288,13290],{},[48,13287,11427],{},[48,13289,3599],{},[48,13291,3619],{},[27,13293,13294,13296,13299],{},[48,13295,13232],{},[48,13297,13298],{},"20A type C",[48,13300,13301],{},"40A type C",[27,13303,13304,13307,13310],{},[48,13305,13306],{},"Temps de charge (batterie 50 kWh)",[48,13308,13309],{},"~14 heures",[48,13311,13312],{},"~7 heures",[17,13314,13315],{},[221,13316,13317],{},"Avantages monophasé :",[711,13319,13320,13323,13326],{},[714,13321,13322],{},"Installation moins chère",[714,13324,13325],{},"Câblage plus simple",[714,13327,13328],{},"Suffisant pour la plupart des ménages (charge nocturne)",[17,13330,13331],{},[221,13332,13333],{},"Inconvénients monophasé :",[711,13335,13336,13339],{},[714,13337,13338],{},"Puissance de charge limitée",[714,13340,13341],{},"À 7,4 kW : déséquilibre de phase possible (attention lors de la déclaration)",[5686,13343,13345],{"id":13344},"triphasé-11-kw-ou-22-kw","Triphasé — 11 kW ou 22 kW",[21,13347,13348,13360],{},[24,13349,13350],{},[27,13351,13352,13354,13357],{},[30,13353,13257],{},[30,13355,13356],{},"11 kW (16A)",[30,13358,13359],{},"22 kW (32A)",[43,13361,13362,13371,13381,13391,13401],{},[27,13363,13364,13366,13369],{},[48,13365,8965],{},[48,13367,13368],{},"Triphasé, 400V",[48,13370,13368],{},[27,13372,13373,13375,13378],{},[48,13374,13279],{},[48,13376,13377],{},"3x 16A",[48,13379,13380],{},"3x 32A",[27,13382,13383,13385,13388],{},[48,13384,11427],{},[48,13386,13387],{},"2,5 mm² (5G2,5)",[48,13389,13390],{},"6 mm² (5G6)",[27,13392,13393,13395,13398],{},[48,13394,13232],{},[48,13396,13397],{},"20A tripolaire type C",[48,13399,13400],{},"32A tripolaire type C",[27,13402,13403,13405,13408],{},[48,13404,13306],{},[48,13406,13407],{},"~5 heures",[48,13409,13410],{},"~2,5 heures",[17,13412,13413],{},[221,13414,13415],{},"Avantages triphasé :",[711,13417,13418,13421,13424],{},[714,13419,13420],{},"Charge nettement plus rapide",[714,13422,13423],{},"Répartition de charge équilibrée (pas de déséquilibre)",[714,13425,13426],{},"Pérenne",[17,13428,13429],{},[221,13430,13431],{},"Inconvénients triphasé :",[711,13433,13434,13437,13440],{},[714,13435,13436],{},"Installation plus coûteuse",[714,13438,13439],{},"Raccordement triphasé au coffret nécessaire",[714,13441,13442],{},"Coûts de matériel plus élevés (câbles plus épais, dispositifs de protection plus chers)",[5686,13444,13446],{"id":13445},"choix-selon-le-projet","Choix selon le projet",[17,13448,13449],{},"Il n'existe pas de puissance universellement optimale pour une maison. Phases disponibles, puissance de raccordement, protection générale, charges simultanées, chargeur embarqué du véhicule, énergie quotidienne et gestion de charge doivent être étudiés ensemble. Une borne de puissance nominale supérieure ne charge pas plus vite si le véhicule ou le raccordement impose la limite.",[12,13451,13453],{"id":13452},"câble-et-protection-le-bon-dimensionnement","Câble et protection : Le bon dimensionnement",[5686,13455,13457],{"id":13456},"aperçu-des-sections-de-câble","Aperçu des sections de câble",[21,13459,13460,13475],{},[24,13461,13462],{},[27,13463,13464,13467,13470,13473],{},[30,13465,13466],{},"Puissance",[30,13468,13469],{},"Type de câble",[30,13471,13472],{},"Section",[30,13474,13232],{},[43,13476,13477,13488,13500,13513],{},[27,13478,13479,13482,13484,13486],{},[48,13480,13481],{},"3,7 kW (1P, 16A)",[48,13483,6008],{},[48,13485,3599],{},[48,13487,13298],{},[27,13489,13490,13493,13496,13498],{},[48,13491,13492],{},"7,4 kW (1P, 32A)",[48,13494,13495],{},"XVB 3G6",[48,13497,3619],{},[48,13499,13301],{},[27,13501,13502,13505,13508,13510],{},[48,13503,13504],{},"11 kW (3P, 16A)",[48,13506,13507],{},"XVB 5G2,5",[48,13509,3599],{},[48,13511,13512],{},"20A 3P type C",[27,13514,13515,13518,13521,13523],{},[48,13516,13517],{},"22 kW (3P, 32A)",[48,13519,13520],{},"XVB 5G6",[48,13522,3619],{},[48,13524,13525],{},"32A 3P type C",[17,13527,13528,13531],{},[221,13529,13530],{},"Important :"," Pour de longues longueurs de câble (>15m), la section doit éventuellement être augmentée pour limiter la chute de tension (RGIE Art. 5.2.5 — variation de tension ; Art. 5.2.1.2b — choix des canalisations). Planifiez le parcours du câble à l'avance et consultez les tableaux de chute de tension en cas de doute.",[5686,13533,13469],{"id":13534},"type-de-câble",[17,13536,13537,13538,13541],{},"En Belgique, on utilise habituellement du ",[221,13539,13540],{},"câble XVB"," pour les installations fixes :",[711,13543,13544,13549,13554,13559],{},[714,13545,13546,13548],{},[221,13547,6008],{}," pour monophasé 16A",[714,13550,13551,13553],{},[221,13552,13495],{}," pour monophasé 32A",[714,13555,13556,13558],{},[221,13557,13507],{}," pour triphasé 16A",[714,13560,13561,13563],{},[221,13562,13520],{}," pour triphasé 32A",[17,13565,13566,13567,13570],{},"Pour une pose en tube Preflex, des ",[221,13568,13569],{},"conducteurs VOB individuels"," sont envisageables (H07V-U), à condition que le tube soit suffisamment dimensionné.",[12,13572,13574],{"id":13573},"type-de-différentiel-le-dispositif-de-protection-le-plus-important","Type de différentiel : Le dispositif de protection le plus important",[17,13576,13577],{},"Le choix du bon différentiel est particulièrement important pour les bornes de recharge — et peut entraîner des différences de coût considérables.",[5686,13579,13581],{"id":13580},"type-a-avec-capteur-de-courant-résiduel-dc","Type A avec capteur de courant résiduel DC",[17,13583,13584,13585,13588],{},"Le chapitre 7.22 impose une protection contre les composantes continues lisses du courant de défaut. Un type A seul n'assure pas cette fonction. Lorsque le fabricant documente une détection DC 6 mA intégrée (RDC-DD) adaptée à la borne exacte, elle peut faire partie d'une solution avec ",[221,13586,13587],{},"différentiel type A 30 mA"," en amont. Ne présumez pas cette combinaison sans preuve du produit.",[17,13590,13591],{},"Le type A choisi doit correspondre au réseau, au nombre de pôles, au calibre et aux conditions documentées de la borne. Sans ces paramètres, une fourchette de prix n'est pas une estimation fiable.",[5686,13593,13595],{"id":13594},"type-b-si-pas-de-capteur-dc-dans-la-borne","Type B (si pas de capteur DC dans la borne)",[17,13597,13598,13599,13602,13603,13606],{},"Si votre borne ",[221,13600,13601],{},"n'a pas"," de capteur de courant résiduel DC intégré, vous avez besoin d'un ",[221,13604,13605],{},"différentiel type B",". Celui-ci détecte également les courants de défaut continus (DC), qui peuvent survenir avec les chargeurs AC\u002FDC.",[17,13608,13609],{},"Vérifiez la déclaration du fabricant concernant la détection des courants résiduels DC. Le nom commercial du produit ne prouve pas, à lui seul, que la borne et le différentiel amont forment un ensemble conforme.",[5686,13611,13613],{"id":13612},"type-a-si-alternative","Type A-SI (alternative)",[17,13615,4930,13616,13619],{},[221,13617,13618],{},"différentiel type A-SI"," peut, selon le fabricant, mieux résister à certaines perturbations, mais il ne remplace pas à lui seul la détection requise des courants de défaut DC lisses. L'ensemble de protection documenté est déterminant.",[12,13621,13623],{"id":13622},"protection-contre-les-surtensions-spd-centralisée-pour-toute-linstallation","Protection contre les surtensions (SPD) — centralisée pour toute l'installation",[17,13625,13626,13627,13630],{},"L'art. 4.5.1 exige de manière générale la protection contre les surtensions selon les règles de l'art. En pratique, un ",[221,13628,13629],{},"SPD (parafoudre)"," est installé dans le coffret de distribution, protégeant tous les appareils raccordés y compris la borne de recharge contre les surtensions transitoires. Le RGIE ne mentionne pas de « Type 2 » spécifique — la désignation de type provient de la norme produit (IEC 61643-11).",[17,13632,13633,13635],{},[221,13634,13530],{}," Le SPD doit être protégé par un fusible amont (fusible gR ou MCB). Respectez les prescriptions du fabricant.",[12,13637,13639],{"id":13638},"gestionnaire-de-réseau-et-sens-de-lénergie","Gestionnaire de réseau et sens de l'énergie",[17,13641,13642],{},"Cet article ne déduit pas de la puissance nominale un seuil universel de déclaration ou de raccordement. Avant la commande, consultez les conditions actuelles du gestionnaire responsable de l'adresse. Préparez code EAN, type de raccordement, puissance projetée, phases, gestion de charge et description exacte du produit.",[17,13644,13645],{},"Déterminez explicitement si l'énergie circule uniquement du réseau vers le véhicule ou dans les deux sens. Synergrid indique que les bornes bidirectionnelles ou techniquement bidirectionnelles relèvent de C10\u002F11 édition 2.4 et nécessitent une homologation C10\u002F26. Les chargeurs strictement réseau-vers-véhicule n'exigent pas C10\u002F26 au titre de cette règle. Cela ne supprime pas automatiquement d'autres formalités, limites de capacité ou conditions du gestionnaire.",[12,13647,13649],{"id":13648},"mettre-à-jour-le-schéma-unifilaire","Mettre à jour le schéma unifilaire",[17,13651,13652,13653,13655],{},"Après l'installation d'une borne de recharge, le schéma unifilaire de votre installation électrique ",[221,13654,13221],{}," être mis à jour. La borne est représentée comme un départ propre dans le schéma :",[5686,13657,13659],{"id":13658},"que-doit-figurer-dans-le-schéma","Que doit figurer dans le schéma ?",[5034,13661,13662,13668,13674,13679,13684,13690,13696],{},[714,13663,13664,13667],{},[221,13665,13666],{},"Circuit propre"," depuis le coffret de distribution",[714,13669,13670,13673],{},[221,13671,13672],{},"Différentiel"," avec indication du type (A ou B)",[714,13675,13676,13678],{},[221,13677,13232],{}," avec courant nominal",[714,13680,13681,13683],{},[221,13682,10779],{}," (protection contre les surtensions)",[714,13685,13686,13689],{},[221,13687,13688],{},"Symbole de borne de recharge"," avec indication de puissance",[714,13691,13692,13695],{},[221,13693,13694],{},"Désignation du câble"," (par ex. XVB 5G2,5)",[714,13697,13698,13701],{},[221,13699,13700],{},"Attribution des phases"," (en triphasé : L1\u002FL2\u002FL3)",[5686,13703,13705],{"id":13704},"planelec-simplifie-les-choses","PlanElec simplifie les choses",[17,13707,13708,13710],{},[221,13709,5823],{}," aide à documenter une borne de recharge dans le projet :",[711,13712,13713,13716,13719,13722],{},[714,13714,13715],{},"Un symbole de borne est disponible pour la représentation sur le plan",[714,13717,13718],{},"L'auto-contrôle peut signaler certaines données prises en charge sur le circuit, le différentiel et le parafoudre",[714,13720,13721],{},"L'attribution des phases peut être saisie directement",[714,13723,13724],{},"L'export PDF reprend les données saisies dans le projet",[12,13726,13728],{"id":13727},"comparer-les-coûts-sur-un-périmètre-technique-commun","Comparer les coûts sur un périmètre technique commun",[17,13730,13731],{},"Un devis utile distingue la borne, les protections, le chemin de câble, les travaux de terrassement, l'adaptation du tableau, la gestion de charge, l'étude, le contrôle et une éventuelle procédure réseau. Le prix varie selon le matériel, la longueur et l'accessibilité du parcours, la puissance de raccordement et l'état du tableau. Demandez donc aux entreprises de chiffrer la même description technique ; une fourchette fixe publiée en ligne n'est pas un budget de projet fiable.",[12,13733,13735],{"id":13734},"éviter-les-erreurs-courantes","Éviter les erreurs courantes",[5034,13737,13738,13744,13750,13756,13762,13768],{},[714,13739,13740,13743],{},[221,13741,13742],{},"Pas de circuit dédié :"," Brancher la borne sur une prise existante est non seulement dangereux, mais contraire au RGIE.",[714,13745,13746,13749],{},[221,13747,13748],{},"Mauvais type de différentiel :"," Sans capteur DC dans la borne, un type B est obligatoire.",[714,13751,13752,13755],{},[221,13753,13754],{},"Surtensions non évaluées :"," La nécessité et la réalisation du SPD s'évaluent pour l'ensemble de l'installation et se coordonnent selon les prescriptions du fabricant.",[714,13757,13758,13761],{},[221,13759,13760],{},"Pas de schéma unifilaire mis à jour :"," Toute modification de l'installation doit être documentée dans le schéma.",[714,13763,13764,13767],{},[221,13765,13766],{},"Conditions réseau non vérifiées :"," Les formalités dépendent du gestionnaire et de la fonction de recharge ; les appareils bidirectionnels ou techniquement bidirectionnels relèvent aussi de C10\u002F11 et C10\u002F26.",[714,13769,13770,13773],{},[221,13771,13772],{},"Section de câble trop faible :"," Surtout pour les longs parcours (>15m), surveillez la chute de tension.",[12,13775,13777],{"id":13776},"conclusion","Conclusion",[17,13779,13780],{},"Une borne en Belgique exige un circuit dédié par point de connexion, des protections différentielle complémentaire et DC adaptées, un dimensionnement propre au projet et des plans à jour. Une documentation soignée facilite le contrôle, sans garantir un rapport positif.",[12,13782,6575],{"id":6574},[711,13784,13785,13792],{},[714,13786,13787],{},[203,13788,13791],{"href":13789,"rel":13790},"https:\u002F\u002Feconomie.fgov.be\u002Fsites\u002Fdefault\u002Ffiles\u002FFiles\u002FPublications\u002Ffiles\u002FRGIE-Annexe-Livre-1-Installations-a-basse-tenstion-et-a-tres-basse-tension-2026.pdf",[5373],"Livre 1 du RGIE, édition 2026 — chapitre 7.22",[714,13793,13794],{},[203,13795,13797],{"href":6589,"rel":13796},[5373],"Synergrid : champ C10\u002F26 des bornes bidirectionnelles ou techniquement bidirectionnelles",[7849,13799],{},[12,13801,10024],{"id":10023},[711,13803,13804,13809],{},[714,13805,13806],{},[203,13807,13808],{"href":1574},"Calculer la chute de tension d'une longue alimentation",[714,13810,13811],{},[203,13812,13813],{"href":210},"Comparatif coût : dessiner soi-même vs. électricien",[711,13815,13816],{},[714,13817,13818],{},[203,13819,13821],{"href":13820},"\u002Ffr\u002Fblog\u002Fplanelec-vs-excel-papier","PlanElec vs. Excel\u002Fpapier",[12,13823,13825],{"id":13824},"documenter-votre-borne-dans-le-schéma-unifilaire","Documenter votre borne dans le schéma unifilaire",[17,13827,6951,13828,13830,13831],{},[221,13829,5823],{},", documentez votre borne dans le schéma unifilaire et exportez le projet en PDF. L'auto-contrôle aide à la préparation, mais ne remplace ni le dimensionnement professionnel ni le contrôle officiel. ",[203,13832,11742],{"href":8394,"rel":13833},[5373],{"title":1212,"searchDepth":1213,"depth":1213,"links":13835},[13836,13842,13847,13851,13856,13857,13858,13862,13863,13864,13865,13866,13867],{"id":13207,"depth":1213,"text":13208,"children":13837},[13838,13839,13840,13841],{"id":13214,"depth":5848,"text":13215},{"id":13225,"depth":5848,"text":13226},{"id":10265,"depth":5848,"text":13232},{"id":12575,"depth":5848,"text":12576},{"id":13243,"depth":1213,"text":13244,"children":13843},[13844,13845,13846],{"id":13247,"depth":5848,"text":13248},{"id":13344,"depth":5848,"text":13345},{"id":13445,"depth":5848,"text":13446},{"id":13452,"depth":1213,"text":13453,"children":13848},[13849,13850],{"id":13456,"depth":5848,"text":13457},{"id":13534,"depth":5848,"text":13469},{"id":13573,"depth":1213,"text":13574,"children":13852},[13853,13854,13855],{"id":13580,"depth":5848,"text":13581},{"id":13594,"depth":5848,"text":13595},{"id":13612,"depth":5848,"text":13613},{"id":13622,"depth":1213,"text":13623},{"id":13638,"depth":1213,"text":13639},{"id":13648,"depth":1213,"text":13649,"children":13859},[13860,13861],{"id":13658,"depth":5848,"text":13659},{"id":13704,"depth":5848,"text":13705},{"id":13727,"depth":1213,"text":13728},{"id":13734,"depth":1213,"text":13735},{"id":13776,"depth":1213,"text":13777},{"id":6574,"depth":1213,"text":6575},{"id":10023,"depth":1213,"text":10024},{"id":13824,"depth":1213,"text":13825},"2026-05-25","Exigences RGIE pour les bornes en Belgique : circuit dédié, protections différentielle et DC, dimensionnement, documentation et règles réseau.",{},"\u002Fblog\u002Fborne-recharge-rgie.fr",{"title":13198,"description":13869},"borne-recharge-rgie","blog\u002Fborne-recharge-rgie.fr",[9283,13876,1242,13877,1133,13878,1249,1248],"wallbox","voiture électrique","protection différentielle","vq8GTIv3hYbuOLHOTBqXAm-hXBv2MsZk458hVFooIU8",{"id":13881,"title":13882,"articleId":13883,"body":13884,"category":8411,"date":14130,"description":14131,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":14132,"navigation":1234,"path":14133,"publishDate":14130,"readTime":12263,"refreshInterval":1237,"seo":14134,"slug":14135,"stem":14136,"tags":14137,"__hash__":14142},"blog\u002Fblog\u002Fcomparatif-cout-soi-meme-vs-electricien.fr.md","Comparatif coût : Dessiner son schéma unifilaire soi-même vs. faire appel à un électricien","cost-comparison-diy-vs-electrician",{"type":9,"value":13885,"toc":14116},[13886,13889,13893,13975,13978,13982,13985,13989,13994,13999,14002,14006,14009,14013,14016,14020,14027,14031,14034,14041,14045,14065,14068,14072,14095,14099,14102,14105,14107,14110],[17,13887,13888],{},"Pour un contrôle belge, les documents doivent représenter l'installation réelle. Une liste de prix générique ne permet pas de décider si l'auto-documentation ou la mission d'un professionnel est la plus économique. Il faut séparer relevé, dessin, responsabilité technique et contrôle.",[12,13890,13892],{"id":13891},"en-bref-comparer-le-même-périmètre","En bref — comparer le même périmètre",[21,13894,13895,13908],{},[24,13896,13897],{},[27,13898,13899,13902,13905],{},[30,13900,13901],{},"Tâche",[30,13903,13904],{},"Auto-documentation avec PlanElec",[30,13906,13907],{},"Mission d'un professionnel",[43,13909,13910,13921,13932,13943,13953,13964],{},[27,13911,13912,13915,13918],{},[48,13913,13914],{},"Relevé de l'existant",[48,13916,13917],{},"seulement pour les données établies sûrement et de façon fiable",[48,13919,13920],{},"peut inclure identification compétente et mesures",[27,13922,13923,13926,13929],{},[48,13924,13925],{},"Schéma et plan de situation",[48,13927,13928],{},"saisie structurée et export PDF",[48,13930,13931],{},"dessin depuis les données fournies ou relevées selon l'offre",[27,13933,13934,13937,13940],{},[48,13935,13936],{},"Étude technique",[48,13938,13939],{},"non remplacée par le logiciel",[48,13941,13942],{},"peut être commandée explicitement",[27,13944,13945,13947,13950],{},[48,13946,6080],{},[48,13948,13949],{},"à organiser séparément",[48,13951,13952],{},"incluse seulement si l'offre le dit",[27,13954,13955,13958,13961],{},[48,13956,13957],{},"Contrôle officiel",[48,13959,13960],{},"organisme agréé séparé",[48,13962,13963],{},"également séparé sauf organisation explicite",[27,13965,13966,13969,13972],{},[48,13967,13968],{},"Base tarifaire",[48,13970,13971],{},"Early Access PlanElec actuellement 0 EUR ; le temps personnel reste un effort",[48,13973,13974],{},"offre liée au projet, sans forfait officiel",[17,13976,13977],{},"Ce tableau ne prouve aucune économie fixe. Des données complètes et vérifiées facilitent l'auto-documentation ; une ancienne installation inconnue peut imposer un relevé professionnel.",[12,13979,13981],{"id":13980},"trois-scénarios-modifiables","Trois scénarios modifiables",[17,13983,13984],{},"Les champs suivants sont des postes de calcul, pas des moyennes belges. Inscrivez les montants de l'offre et votre propre valeur du temps.",[5686,13986,13988],{"id":13987},"_1-installation-existante-avec-dossier-fiable","1. Installation existante avec dossier fiable",[17,13990,13991],{},[4068,13992,13993],{},"voie professionnelle = relevé offert + dessin + vérification + contrôle",[17,13995,13996],{},[4068,13997,13998],{},"voie personnelle = heures propres × valeur personnelle + vérification + contrôle",[17,14000,14001],{},"Si le plan, les tableaux, protections et affectations sont vérifiés, le travail personnel peut se concentrer sur la saisie et la cohérence. Une donnée technique inconnue reste inconnue. Une entreprise peut aussi contrôler ce jeu de données limité et réaliser les plans.",[5686,14003,14005],{"id":14004},"_2-installation-sans-affectations-fiables","2. Installation sans affectations fiables",[17,14007,14008],{},"Il faut d'abord établir en sécurité quel circuit alimente chaque élément, quelle protection est présente et quelles données des conducteurs sont connues. Ouvrir des enveloppes et effectuer des mesures électriques ne sont pas des travaux de bricolage. Ajoutez un relevé professionnel dans le scénario personnel. Le prix nul d'un logiciel ne supprime pas ce travail nécessaire.",[5686,14010,14012],{"id":14011},"_3-installation-nouvelle-ou-modification-importante","3. Installation nouvelle ou modification importante",[17,14014,14015],{},"L'étude technique précède le dessin des nouveaux circuits ou sources. Les prescriptions du fabricant, les conditions du gestionnaire de réseau et le RGIE applicable peuvent changer la solution. Ne comparez pas une étude et exécution complètes avec un simple dessin. Séparez étude, exécution, documentation et contrôle.",[12,14017,14019],{"id":14018},"quel-résultat-faut-il-obtenir","Quel résultat faut-il obtenir ?",[17,14021,1759,14022,14026],{},[203,14023,14025],{"href":6185,"rel":14024},[5373],"page officielle du SPF Économie"," cite schéma unifilaire et plan de position parmi les pièces minimales d'un contrôle domestique. Le schéma reprend les données de canalisations, modes de pose et protections ; le plan localise les éléments correspondants. Tous deux appartiennent au dossier. Le résultat compte, pas l'outil qui trace les lignes.",[12,14028,14030],{"id":14029},"ce-que-planelec-fournit-aujourdhui","Ce que PlanElec fournit aujourd'hui",[17,14032,14033],{},"PlanElec réunit plan du bâtiment, topologie électrique et planification du tableau. Les PDF du schéma unifilaire et du plan de situation sont disponibles. L'auto-contrôle couvre un sous-ensemble documenté des règles décidables depuis les données ; ce n'est pas une attestation. La liste de matériel et le dossier de travail sont des fonctions pilotes avec limites visibles. Devis et paiement ne sont pas actifs.",[17,14035,14036,14037,14040],{},"Le seul énoncé tarifaire vérifié est : ",[221,14038,14039],{},"frais de produit de l'Early Access actuellement à 0 EUR",". Il n'existe ni paiement actif ni futur tarif publié. Temps, prestations professionnelles, travaux et contrôle officiel restent payants selon leur propre contrat.",[12,14042,14044],{"id":14043},"quand-laide-professionnelle-est-indispensable","Quand l'aide professionnelle est indispensable",[711,14046,14047,14050,14053,14056,14059,14062],{},[714,14048,14049],{},"quand le relevé sûr exige mesures ou ouverture d'enveloppes ;",[714,14051,14052],{},"quand conducteurs, coordination des protections ou terre sont incertains ;",[714,14054,14055],{},"quand circuits, PV, stockage, recharge ou secours sont conçus ;",[714,14057,14058],{},"quand un rapport signale des infractions physiques ;",[714,14060,14061],{},"quand il faut évaluer fabricant ou gestionnaire de réseau ;",[714,14063,14064],{},"quand la responsabilité des décisions techniques doit être confiée.",[17,14066,14067],{},"« Dessiner soi-même » ne signifie pas « installer soi-même ». Un logiciel de documentation ne donne aucune compétence électrique.",[12,14069,14071],{"id":14070},"sept-questions-pour-chaque-offre","Sept questions pour chaque offre",[5034,14073,14074,14077,14080,14083,14086,14089,14092],{},[714,14075,14076],{},"Qui réunit et vérifie les données ?",[714,14078,14079],{},"Les deux plans et tous les tableaux sont-ils compris ?",[714,14081,14082],{},"La mission comprend-elle les calculs ou seulement la reprise graphique ?",[714,14084,14085],{},"Qui vérifie la plausibilité technique ?",[714,14087,14088],{},"Comment les changements et corrections sont-ils facturés ?",[714,14090,14091],{},"TVA, déplacement et contrôle sont-ils séparés ?",[714,14093,14094],{},"Quel fichier modifiable et quels PDF sont remis ?",[12,14096,14098],{"id":14097},"une-règle-de-décision-équitable","Une règle de décision équitable",[17,14100,14101],{},"Choisissez l'auto-documentation lorsque les données sont fiables, le projet domestique reste maîtrisable et une vérification est prévue pour les incertitudes. Choisissez une mission professionnelle lorsque l'installation est inconnue, des choix techniques restent ouverts, des mesures sont nécessaires ou une coordination est souhaitée. Une voie hybride est souvent rationnelle : organiser les informations dans PlanElec, marquer les inconnues, puis demander à l'électricien de vérifier ce qui exige son jugement.",[17,14103,14104],{},"Consignez les hypothèses. Si l'offre exclut l'identification des circuits, indiquez qui fournit les affectations vérifiées. Si votre calcul ne valorise pas votre temps, rendez cette exclusion visible. Après des travaux, mettez les deux plans à jour. La transparence est plus utile qu'un pourcentage d'économie.",[12,14106,13777],{"id":13776},[17,14108,14109],{},"L'auto-documentation convient à un projet aux données vérifiées et aux limites professionnelles respectées. Une mission d'électricien peut être plus sûre et économique si relevé, étude ou responsabilité sont requis. Calculez avec des offres réelles et votre temps noté, sans promettre économie standard ni contrôle positif.",[17,14111,14112],{},[203,14113,14115],{"href":8394,"rel":14114},[5373],"Ouvrir PlanElec dans l'Early Access actuellement gratuit →",{"title":1212,"searchDepth":1213,"depth":1213,"links":14117},[14118,14119,14124,14125,14126,14127,14128,14129],{"id":13891,"depth":1213,"text":13892},{"id":13980,"depth":1213,"text":13981,"children":14120},[14121,14122,14123],{"id":13987,"depth":5848,"text":13988},{"id":14004,"depth":5848,"text":14005},{"id":14011,"depth":5848,"text":14012},{"id":14018,"depth":1213,"text":14019},{"id":14029,"depth":1213,"text":14030},{"id":14043,"depth":1213,"text":14044},{"id":14070,"depth":1213,"text":14071},{"id":14097,"depth":1213,"text":14098},{"id":13776,"depth":1213,"text":13777},"2026-05-19","Comment comparer l'auto-documentation et une mission professionnelle en Belgique sans prix de marché ni promesse d'économie non étayés.",{},"\u002Fblog\u002Fcomparatif-cout-soi-meme-vs-electricien.fr",{"title":13882,"description":14131},"comparatif-cout-soi-meme-vs-electricien","blog\u002Fcomparatif-cout-soi-meme-vs-electricien.fr",[14138,14139,1248,14140,5823,14141,1249],"coût","électricien","soi-même","contrôle","S_SXfP6a96SxitTXN8hvAECNQRI4kWs_NEmX0BKA_yc",{"id":14144,"title":14145,"articleId":14146,"body":14147,"category":8411,"date":14539,"description":14540,"extension":1231,"lastUpdated":13185,"locale":1232,"meta":14541,"navigation":1234,"path":14542,"publishDate":14539,"readTime":14543,"refreshInterval":1237,"seo":14544,"slug":14545,"stem":14546,"tags":14547,"__hash__":14551},"blog\u002Fblog\u002Fplanelec-vs-excel-papier.fr.md","PlanElec vs. Excel & papier : Pourquoi les schémas unifilaires numériques sont meilleurs","planelec-vs-excel-paper",{"type":9,"value":14148,"toc":14511},[14149,14152,14155,14159,14293,14297,14300,14303,14307,14311,14314,14318,14321,14325,14328,14332,14335,14339,14343,14346,14350,14353,14357,14360,14364,14367,14371,14375,14378,14382,14385,14389,14392,14408,14412,14415,14419,14422,14426,14429,14434,14457,14462,14467,14477,14480,14484,14487,14489,14492,14495,14497,14499,14503],[12928,14150,14145],{"id":14151},"planelec-vs-excel-papier-pourquoi-les-schémas-unifilaires-numériques-sont-meilleurs",[17,14153,14154],{},"De nombreux propriétaires et même certains électriciens utilisent encore un stylo et du papier ou Excel lorsqu'ils doivent créer un schéma unifilaire. Cela semble gratuit et simple au premier abord — mais comporte des risques considérables. Dans cette comparaison, nous montrons pourquoi un outil spécialisé comme PlanElec est le meilleur choix.",[12,14156,14158],{"id":14157},"tldr-comparaison-en-un-coup-dœil","TL;DR — Comparaison en un coup d'œil",[21,14160,14161,14175],{},[24,14162,14163],{},[27,14164,14165,14167,14169,14172],{},[30,14166,7958],{},[30,14168,5823],{},[30,14170,14171],{},"Excel\u002FWord",[30,14173,14174],{},"Papier",[43,14176,14177,14191,14207,14222,14236,14251,14267,14280],{},[27,14178,14179,14184,14186,14189],{},[48,14180,14181],{},[221,14182,14183],{},"Coût",[48,14185,9934],{},[48,14187,14188],{},"\"Gratuit\"",[48,14190,14188],{},[27,14192,14193,14198,14201,14204],{},[48,14194,14195],{},[221,14196,14197],{},"Symboles RGIE",[48,14199,14200],{},"✅ Corrects",[48,14202,14203],{},"❌ Aucun",[48,14205,14206],{},"❌ Souvent faux",[27,14208,14209,14214,14217,14220],{},[48,14210,14211],{},[221,14212,14213],{},"Mise en page auto",[48,14215,14216],{},"✅",[48,14218,14219],{},"❌",[48,14221,14219],{},[27,14223,14224,14229,14232,14234],{},[48,14225,14226],{},[221,14227,14228],{},"Auto-contrôle RGIE",[48,14230,14231],{},"✅ Indicatif",[48,14233,14219],{},[48,14235,14219],{},[27,14237,14238,14243,14246,14249],{},[48,14239,14240],{},[221,14241,14242],{},"Export PDF",[48,14244,14245],{},"✅ Centralisé",[48,14247,14248],{},"⚠️ Manuel",[48,14250,14219],{},[27,14252,14253,14258,14261,14264],{},[48,14254,14255],{},[221,14256,14257],{},"Modifications",[48,14259,14260],{},"✅ À tout moment",[48,14262,14263],{},"⚠️ Laborieux",[48,14265,14266],{},"❌ Redessiner",[27,14268,14269,14273,14276,14278],{},[48,14270,14271],{},[221,14272,13957],{},[48,14274,14275],{},"Requis séparément",[48,14277,14275],{},[48,14279,14275],{},[27,14281,14282,14286,14289,14291],{},[48,14283,14284],{},[221,14285,6995],{},[48,14287,14288],{},"✅ Intégré",[48,14290,14219],{},[48,14292,14219],{},[12,14294,14296],{"id":14295},"la-réalité-beaucoup-dessinent-encore-à-la-main","La réalité : Beaucoup dessinent encore à la main",[17,14298,14299],{},"Bien que nous soyons en 2026, la réalité en Belgique est souvent encore analogique. Lors de rénovations, d'extensions ou de la vente d'un bien immobilier, les propriétaires doivent présenter un schéma unifilaire et un plan de situation à jour. Beaucoup se tournent alors vers ce qu'ils connaissent : une feuille de papier ou un tableau Excel.",[17,14301,14302],{},"Le problème ? Le contrôleur lors du contrôle électrique attend des plans conformes aux normes — et ceux-ci sont pratiquement impossibles à réaliser sur papier ou dans Excel.",[12,14304,14306],{"id":14305},"problèmes-avec-le-papier","Problèmes avec le papier",[5686,14308,14310],{"id":14309},"non-conforme-aux-normes","Non conforme aux normes",[17,14312,14313],{},"Le RGIE (Règlement Général sur les Installations Électriques) prescrit certains symboles (Tableau 2.23, basé sur IEC 60617). Les symboles dessinés à la main ne correspondent presque jamais aux exigences normatives. Un contrôleur peut refuser le plan si les symboles ne sont pas corrects.",[5686,14315,14317],{"id":14316},"difficile-à-modifier","Difficile à modifier",[17,14319,14320],{},"Vous avez fait une erreur ou oublié une prise ? Avec un plan dessiné à la main, vous devez redessiner l'intégralité du schéma. Pour des installations complexes avec 20+ circuits, c'est un investissement en temps énorme.",[5686,14322,14324],{"id":14323},"illisible","Illisible",[17,14326,14327],{},"L'écriture manuscrite est subjective. Ce qui est clair pour vous peut être illisible pour le contrôleur. Les corrections rayées aggravent encore la situation.",[5686,14329,14331],{"id":14330},"risque-de-refus-au-contrôle","Risque de refus au contrôle",[17,14333,14334],{},"De plus en plus de contrôleurs n'acceptent les plans dessinés à la main qu'à contrecœur. Le RGIE (Art. 9.1.2) ne prescrit pas que les plans doivent être réalisés de manière numérique. L'essentiel est que la documentation soit lisible, complète et conforme aux normes. Un plan soigneusement dessiné à la main avec des symboles RGIE corrects est autorisé selon le RGIE — mais le risque de contestation en cas de dessins manuscrits illisibles ou erronés reste élevé.",[12,14336,14338],{"id":14337},"problèmes-avec-excel","Problèmes avec Excel",[5686,14340,14342],{"id":14341},"pas-de-symboles-rgie","Pas de symboles RGIE",[17,14344,14345],{},"Excel ne connaît pas les symboles électriques. Vous devriez insérer chaque symbole comme image ou le reconstituer laborieusement avec des formes. Le résultat a l'air non professionnel et ne respecte pas la norme.",[5686,14347,14349],{"id":14348},"pas-de-mise-en-page-automatique","Pas de mise en page automatique",[17,14351,14352],{},"Un schéma unifilaire a une structure claire : interrupteur principal, différentiels, disjoncteurs, consommateurs — le tout dans une hiérarchie définie. Dans Excel, vous devez construire cette structure manuellement et l'adapter à chaque modification.",[5686,14354,14356],{"id":14355},"pas-de-validation","Pas de validation",[17,14358,14359],{},"Excel ne vérifie pas si votre schéma est conforme au RGIE. Manque-t-il un différentiel ? La section de câble est-elle trop petite ? Avez-vous trop de circuits par RCD ? Excel ne le sait pas — mais le contrôleur, si.",[5686,14361,14363],{"id":14362},"problèmes-de-mise-en-forme","Problèmes de mise en forme",[17,14365,14366],{},"Les schémas plus grands ne tiennent pas sur une page A4. L'aperçu d'impression d'Excel est tristement célèbre pour ses sauts de page inattendus et ses contenus coupés.",[12,14368,14370],{"id":14369},"avantages-de-planelec-en-détail","Avantages de PlanElec en détail",[5686,14372,14374],{"id":14373},"symboles-conformes-aux-normes","Symboles conformes aux normes",[17,14376,14377],{},"PlanElec fournit un catalogue de symboles électriques pour le contexte de planification belge. Le professionnel doit déterminer les symboles et données requis pour le projet concret.",[5686,14379,14381],{"id":14380},"mise-en-page-automatique-goethals-jacobs","Mise en page automatique (Goethals-Jacobs)",[17,14383,14384],{},"PlanElec déduit de la topologie saisie une représentation structurée avec jeux de barres, protections et récepteurs. La justesse professionnelle dépend des données du projet.",[5686,14386,14388],{"id":14387},"auto-contrôle-rgie-assisté","Auto-contrôle RGIE assisté",[17,14390,14391],{},"L'auto-contrôle signale certaines erreurs de planification prises en charge, notamment pour les protections et le dimensionnement des câbles. Il ne constitue pas une preuve complète de conformité. L'état interne des règles date actuellement du 31.03.2025 ; les modifications de 2026 restent à intégrer.",[711,14393,14394,14397,14400,14402,14405],{},[714,14395,14396],{},"Nombre maximum de circuits par RCD : max. 8 (Art. 4.2.4.3b)",[714,14398,14399],{},"Sections de câble adaptées au disjoncteur",[714,14401,12576],{},[714,14403,14404],{},"Protection zones salle de bain (Art. 7.1)",[714,14406,14407],{},"Et bien plus encore",[5686,14409,14411],{"id":14410},"modifiable-à-tout-moment","Modifiable à tout moment",[17,14413,14414],{},"Prise oubliée ? Ajouter un circuit ? Avec PlanElec, vous ajoutez des modifications en secondes. La mise en page s'adapte automatiquement — pas besoin de redessiner, pas de chaos de mise en forme.",[5686,14416,14418],{"id":14417},"export-pdf-professionnel","Export PDF professionnel",[17,14420,14421],{},"Un clic et vous obtenez un PDF professionnel au format A4 paysage — avec cartouche, pagination et symboles conformes aux normes. Exactement ce que le contrôleur attend.",[12,14423,14425],{"id":14424},"largument-du-prix-gratuit-a-un-coût","L'argument du prix : \"Gratuit\" a un coût",[17,14427,14428],{},"Papier et Excel semblent gratuits. Mais faisons le calcul :",[17,14430,14431],{},[221,14432,14433],{},"Scénario : Refus au contrôle",[5034,14435,14436,14439,14445,14451],{},[714,14437,14438],{},"Vous dessinez votre schéma sur papier ou dans Excel : €0",[714,14440,14441,14442],{},"Le contrôleur refuse le plan : recontrôle ",[221,14443,14444],{},"€80-120",[714,14446,14447,14448],{},"Vous engagez un électricien pour refaire le plan : ",[221,14449,14450],{},"€150-300",[714,14452,14453,14454],{},"Nouveau contrôle : ",[221,14455,14456],{},"€150-200",[17,14458,14459],{},[221,14460,14461],{},"Coût total en cas de refus : €380-620",[17,14463,14464],{},[221,14465,14466],{},"Avec PlanElec :",[5034,14468,14469,14474],{},[714,14470,14471,14472],{},"Créer le schéma unifilaire avec PlanElec : ",[221,14473,9934],{},[714,14475,14476],{},"Faire vérifier la documentation par un professionnel et effectuer séparément le contrôle officiel",[17,14478,14479],{},"Les coûts de la vérification professionnelle et du contrôle officiel restent indépendants de l'outil de planification utilisé. Une économie totale fixe ne peut donc pas être promise sérieusement.",[12,14481,14483],{"id":14482},"quand-le-papier-fonctionne-encore","Quand le papier fonctionne encore",[17,14485,14486],{},"En toute honnêteté : pour des installations très simples (par ex. un seul circuit dans un abri de jardin), certains contrôleurs acceptent encore un plan proprement dessiné à la main. Mais dès que l'installation comporte plus de 3-4 circuits, le papier devient confus et source d'erreurs.",[12,14488,13777],{"id":13776},[17,14490,14491],{},"Le papier et Excel ne sont pas des outils adaptés à la création de schémas unifilaires. L'absence de symboles normalisés, la mise en page manuelle et l'absence de validation annulent rapidement l'avantage supposé du coût — au plus tard lors du contrôle.",[17,14493,14494],{},"PlanElec réunit le plan, la topologie électrique et la planification du tableau et exporte aujourd'hui le schéma unifilaire et le plan de situation en PDF. Le rapport d'auto-contrôle intégré est indicatif et ne remplace pas le contrôle officiel.",[7849,14496],{},[12,14498,10024],{"id":10023},[12,14500,14502],{"id":14501},"fini-le-papier-et-excel","Fini le papier et Excel !",[17,14504,6951,14505,14507,14508],{},[221,14506,5823],{},", planifiez le plan, la topologie électrique et le tableau dans un même projet, puis exportez le schéma unifilaire et le plan de situation en PDF. L'auto-contrôle aide à la préparation et ne remplace pas le contrôle officiel. ",[203,14509,11742],{"href":8394,"rel":14510},[5373],{"title":1212,"searchDepth":1213,"depth":1213,"links":14512},[14513,14514,14515,14521,14527,14534,14535,14536,14537,14538],{"id":14157,"depth":1213,"text":14158},{"id":14295,"depth":1213,"text":14296},{"id":14305,"depth":1213,"text":14306,"children":14516},[14517,14518,14519,14520],{"id":14309,"depth":5848,"text":14310},{"id":14316,"depth":5848,"text":14317},{"id":14323,"depth":5848,"text":14324},{"id":14330,"depth":5848,"text":14331},{"id":14337,"depth":1213,"text":14338,"children":14522},[14523,14524,14525,14526],{"id":14341,"depth":5848,"text":14342},{"id":14348,"depth":5848,"text":14349},{"id":14355,"depth":5848,"text":14356},{"id":14362,"depth":5848,"text":14363},{"id":14369,"depth":1213,"text":14370,"children":14528},[14529,14530,14531,14532,14533],{"id":14373,"depth":5848,"text":14374},{"id":14380,"depth":5848,"text":14381},{"id":14387,"depth":5848,"text":14388},{"id":14410,"depth":5848,"text":14411},{"id":14417,"depth":5848,"text":14418},{"id":14424,"depth":1213,"text":14425},{"id":14482,"depth":1213,"text":14483},{"id":13776,"depth":1213,"text":13777},{"id":10023,"depth":1213,"text":10024},{"id":14501,"depth":1213,"text":14502},"2026-05-05","Comparaison entre PlanElec et la création de schémas unifilaires avec Excel ou sur papier. Pourquoi les plans dessinés à la main échouent au contrôle et pourquoi les outils numériques font gagner temps et argent.",{},"\u002Fblog\u002Fplanelec-vs-excel-papier.fr","5 min",{"title":14145,"description":14540},"planelec-vs-excel-papier","blog\u002Fplanelec-vs-excel-papier.fr",[5823,14548,14549,14550,1248,1242,14141],"Excel","papier","comparaison","KR4Xvx7nF9EVN5fzCLNQWS52hqbKEGYHwuUMq1ncNhI",{"id":14553,"title":14554,"articleId":14555,"body":14556,"category":1228,"date":15567,"description":15568,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":15569,"navigation":1234,"path":15570,"publishDate":15567,"readTime":5436,"refreshInterval":1237,"seo":15571,"slug":15572,"stem":15573,"tags":15574,"__hash__":15578},"blog\u002Fblog\u002Fpv-system-documentation.fr.md","Panneaux solaires dans le schéma : Documentation et prescriptions RGIE pour les installations PV","pv-system-documentation",{"type":9,"value":14557,"toc":15533},[14558,14561,14563,14567,14570,14590,14595,14606,14608,14612,14615,14619,14625,14629,14709,14711,14715,14719,14774,14789,14793,14845,14849,14906,14918,14920,14924,14931,14990,15004,15006,15008,15012,15050,15054,15086,15090,15114,15118,15145,15147,15151,15155,15162,15182,15189,15193,15200,15218,15220,15231,15233,15237,15240,15244,15250,15254,15257,15273,15285,15287,15291,15302,15418,15422,15429,15450,15456,15458,15462,15465,15479,15481,15483,15503,15505,15515,15519,15522,15530],[17,14559,14560],{},"Une installation photovoltaïque (PV) sur le toit n'est pas seulement un investissement pour l'avenir en Belgique — elle doit aussi être correctement documentée et déclarée auprès du gestionnaire de réseau de distribution (GRD). Dans cet article, vous apprendrez comment l'installation PV est représentée dans le schéma unifilaire, quels dispositifs de protection sont nécessaires et ce qu'il faut savoir lors de la déclaration.",[7849,14562],{},[12,14564,14566],{"id":14565},"pourquoi-la-documentation-est-elle-obligatoire","Pourquoi la documentation est-elle obligatoire ?",[17,14568,14569],{},"Toute installation PV doit apparaître dans la documentation électrique de votre bâtiment — c'est-à-dire :",[5034,14571,14572,14578,14584],{},[714,14573,14574,14577],{},[221,14575,14576],{},"Schéma unifilaire :"," L'installation PV avec tous ses composants (modules, onduleur, protections) doit être dessinée.",[714,14579,14580,14583],{},[221,14581,14582],{},"Plan de situation :"," La position de l'onduleur et du sectionneur DC doit être marquée.",[714,14585,14586,14589],{},[221,14587,14588],{},"Déclaration au GRD :"," L'installation doit être enregistrée auprès du gestionnaire de réseau compétent.",[17,14591,14592],{},[221,14593,14594],{},"Sans documentation correcte :",[711,14596,14597,14600,14603],{},[714,14598,14599],{},"Le contrôle RGIE échoue.",[714,14601,14602],{},"Le GRD peut refuser le raccordement au réseau.",[714,14604,14605],{},"Le droit à la compensation ou au tarif prosommateur est perdu.",[7849,14607],{},[12,14609,14611],{"id":14610},"que-doit-contenir-le-schéma-unifilaire","Que doit contenir le schéma unifilaire ?",[17,14613,14614],{},"L'installation PV est représentée comme une branche distincte dans le schéma unifilaire. Le flux de signal va des modules jusqu'au point d'injection :",[5686,14616,14618],{"id":14617},"chaîne-de-composants","Chaîne de composants",[5508,14620,14623],{"className":14621,"code":14622,"language":5513},[5511],"Modules PV (strings)\n   │\n   ├── Câble DC (câble solaire, par ex. 6 mm²)\n   │\n   ├── Sectionneur DC (interrupteur pompiers)\n   │\n   ├── Parafoudre DC (côté DC)\n   │\n   └── Onduleur (Inverter)\n         │\n         ├── Parafoudre AC (côté AC)\n         │\n         ├── Disjoncteur pour circuit PV (par ex. C20A)\n         │\n         ├── Différentiel 30 mA Type A (ou Type B pour onduleur sans transformateur)\n         │\n         └── Point d'injection (raccordement au tableau principal)\n",[4068,14624,14622],{"__ignoreMap":1212},[5686,14626,14628],{"id":14627},"symboles-dans-le-schéma","Symboles dans le schéma",[21,14630,14631,14644],{},[24,14632,14633],{},[27,14634,14635,14638,14641],{},[30,14636,14637],{},"Composant",[30,14639,14640],{},"Symbole RGIE",[30,14642,14643],{},"Remarque",[43,14645,14646,14657,14667,14678,14689,14699],{},[27,14647,14648,14651,14654],{},[48,14649,14650],{},"Module PV",[48,14652,14653],{},"Rectangle avec symbole soleil",[48,14655,14656],{},"Indiquer nombre et puissance (par ex. « 12x 400 Wc »)",[27,14658,14659,14661,14664],{},[48,14660,6997],{},[48,14662,14663],{},"Rectangle avec « ~ » et « = »",[48,14665,14666],{},"Entrée DC \u002F Sortie AC",[27,14668,14669,14672,14675],{},[48,14670,14671],{},"Sectionneur DC",[48,14673,14674],{},"Symbole interrupteur avec « DC »",[48,14676,14677],{},"Coupure pompiers",[27,14679,14680,14683,14686],{},[48,14681,14682],{},"Parafoudre",[48,14684,14685],{},"Symbole éclair avec terre",[48,14687,14688],{},"Côté DC ET côté AC",[27,14690,14691,14693,14696],{},[48,14692,13232],{},[48,14694,14695],{},"Symbole MCB standard",[48,14697,14698],{},"La caractéristique B suffit pour la plupart des onduleurs modernes avec soft-start ; C uniquement en cas de courant d'appel élevé (consultez les spécifications du fabricant)",[27,14700,14701,14703,14706],{},[48,14702,13672],{},[48,14704,14705],{},"Symbole RCD standard",[48,14707,14708],{},"Indiquer le type (A ou B)",[7849,14710],{},[12,14712,14714],{"id":14713},"dispositifs-de-protection-pour-installations-pv","Dispositifs de protection pour installations PV",[5686,14716,14718],{"id":14717},"côté-dc-entre-modules-et-onduleur","Côté DC (entre modules et onduleur)",[21,14720,14721,14734],{},[24,14722,14723],{},[27,14724,14725,14728,14731],{},[30,14726,14727],{},"Dispositif",[30,14729,14730],{},"Fonction",[30,14732,14733],{},"Obligatoire ?",[43,14735,14736,14748,14761],{},[27,14737,14738,14742,14745],{},[48,14739,14740],{},[221,14741,14671],{},[48,14743,14744],{},"Mise hors tension des modules PV",[48,14746,14747],{},"Recommandé \u002F bonne pratique (souvent une exigence du fabricant ou du GRD ; ne découle pas de l'Art. 7.112)",[27,14749,14750,14755,14758],{},[48,14751,14752],{},[221,14753,14754],{},"Parafoudre DC",[48,14756,14757],{},"Protection contre les surtensions côté DC",[48,14759,14760],{},"Art. 4.5.1 exige de manière générale la protection contre les surtensions selon les règles de l'art ; en pratique recommandé pour le PV, notamment pour modules à >10 m de l'onduleur ou câbles en toiture",[27,14762,14763,14768,14771],{},[48,14764,14765],{},[221,14766,14767],{},"Fusibles de string",[48,14769,14770],{},"Protection en cas de strings multiples",[48,14772,14773],{},"À partir de 3+ strings parallèles",[9883,14775,14776],{},[17,14777,14778,14781,14782,207,14785,14788],{},[221,14779,14780],{},"Sectionneur DC :"," Un dispositif de sectionnement DC relève des bonnes pratiques (et est exigé par de nombreux fabricants d'onduleurs ou GRD) ; il ne découle toutefois pas de l'Art. 7.112. Il devrait être ",[221,14783,14784],{},"facilement accessible",[221,14786,14787],{},"clairement identifié",", et peut également être installé à l'intérieur du bâtiment, à condition de rester repérable.",[5686,14790,14792],{"id":14791},"côté-ac-entre-onduleur-et-tableau","Côté AC (entre onduleur et tableau)",[21,14794,14795,14805],{},[24,14796,14797],{},[27,14798,14799,14801,14803],{},[30,14800,14727],{},[30,14802,14730],{},[30,14804,14733],{},[43,14806,14807,14820,14832],{},[27,14808,14809,14814,14817],{},[48,14810,14811],{},[221,14812,14813],{},"Parafoudre AC",[48,14815,14816],{},"Protection contre les surtensions côté AC",[48,14818,14819],{},"Art. 4.5.1 — protection contre les surtensions selon les règles de l'art",[27,14821,14822,14827,14830],{},[48,14823,14824],{},[221,14825,14826],{},"Disjoncteur (caractéristique C)",[48,14828,14829],{},"Protection contre court-circuit et surcharge",[48,14831,8064],{},[27,14833,14834,14839,14842],{},[48,14835,14836],{},[221,14837,14838],{},"Différentiel 30 mA",[48,14840,14841],{},"Protection différentielle",[48,14843,14844],{},"Recommandé (un RCD dédié par circuit AC PV n'est pas imposé par le RGIE ; le circuit doit être protégé par les mesures de protection générales)",[5686,14846,14848],{"id":14847},"quel-type-de-différentiel","Quel type de différentiel ?",[21,14850,14851,14864],{},[24,14852,14853],{},[27,14854,14855,14858,14861],{},[30,14856,14857],{},"Type d'onduleur",[30,14859,14860],{},"Type de différentiel",[30,14862,14863],{},"Pourquoi ?",[43,14865,14866,14880,14894],{},[27,14867,14868,14874,14877],{},[48,14869,14870,14873],{},[221,14871,14872],{},"Avec transformateur"," (séparation galvanique)",[48,14875,14876],{},"Type A",[48,14878,14879],{},"Pas de courant de défaut DC possible",[27,14881,14882,14888,14891],{},[48,14883,14884,14887],{},[221,14885,14886],{},"Sans transformateur"," (sans séparation galvanique)",[48,14889,14890],{},"Type B",[48,14892,14893],{},"Courants de défaut DC possibles",[27,14895,14896,14901,14903],{},[48,14897,14898],{},[221,14899,14900],{},"Avec RCMU intégrée",[48,14902,14876],{},[48,14904,14905],{},"La RCMU détecte les courants DC en interne",[9883,14907,14908],{},[17,14909,14910,14913,14914,14917],{},[221,14911,14912],{},"Conseil :"," Les onduleurs modernes ont souvent une ",[221,14915,14916],{},"RCMU"," (Residual Current Monitoring Unit) intégrée qui détecte les courants de défaut DC. Dans ce cas, un différentiel Type A suffit. Vérifiez les spécifications du fabricant.",[7849,14919],{},[12,14921,14923],{"id":14922},"onduleur-homologation-selon-synergrid-c1026","Onduleur : homologation selon Synergrid C10\u002F26",[17,14925,14926,14927,14930],{},"Avant que le gestionnaire de réseau n'autorise l'injection, l'onduleur lui-même doit être admis. La référence est la ",[221,14928,14929],{},"liste Synergrid C10\u002F26"," – le registre des appareils homologués selon la prescription technique C10\u002F11 (annexe D). Elle vaut dans tout le pays, donc aussi en Wallonie et à Bruxelles.",[21,14932,14933,14943],{},[24,14934,14935],{},[27,14936,14937,14940],{},[30,14938,14939],{},"Ce qu'il faut vérifier",[30,14941,14942],{},"Pourquoi c'est déterminant",[43,14944,14945,14960,14970,14980],{},[27,14946,14947,14952],{},[48,14948,14949],{},[221,14950,14951],{},"Modèle exact",[48,14953,14954,14955,14957,14958,306],{},"Les suffixes distinguent les lignes (",[4068,14956,7713],{}," ≠ ",[4068,14959,7716],{},[27,14961,14962,14967],{},[48,14963,14964],{},[221,14965,14966],{},"Version de firmware",[48,14968,14969],{},"L'homologation vaut par version ; une version différente est considérée comme non homologuée",[27,14971,14972,14977],{},[48,14973,14974],{},[221,14975,14976],{},"Statut",[48,14978,14979],{},"Synergrid retire des lignes ; une homologation expirée n'est plus utilisable pour une nouvelle installation",[27,14981,14982,14987],{},[48,14983,14984],{},[221,14985,14986],{},"Appareil batterie \u002F hybride",[48,14988,14989],{},"L'onduleur de batterie a lui aussi besoin d'une ligne – les batteries DC dépendent de l'hybride listé",[17,14991,14992,14993,14995,14996,14999,15000,212],{},"Vérifiez votre appareil gratuitement avec la ",[203,14994,7754],{"href":7412}," (pour le stockage : ",[203,14997,14998],{"href":7696},"vérification batterie domestique","). En l'absence de résultat, l'outil propose des appareils homologués comparables. Pour lire référence, Smax et restrictions : ",[203,15001,15003],{"href":15002},"\u002Ffr\u002Fblog\u002Fliste-synergrid-c10-26-onduleur","la liste Synergrid C10\u002F26 expliquée",[7849,15005],{},[12,15007,7459],{"id":12704},[5686,15009,15011],{"id":15010},"grd-compétents-en-belgique","GRD compétents en Belgique",[21,15013,15014,15023],{},[24,15015,15016],{},[27,15017,15018,15020],{},[30,15019,13036],{},[30,15021,15022],{},"Gestionnaire de réseau",[43,15024,15025,15033,15042],{},[27,15026,15027,15031],{},[48,15028,15029],{},[221,15030,12944],{},[48,15032,9280],{},[27,15034,15035,15039],{},[48,15036,15037],{},[221,15038,12974],{},[48,15040,15041],{},"ORES, RESA, REW",[27,15043,15044,15048],{},[48,15045,15046],{},[221,15047,12999],{},[48,15049,9282],{},[5686,15051,15053],{"id":15052},"déroulement-de-la-déclaration","Déroulement de la déclaration",[5034,15055,15056,15062,15068,15074,15080],{},[714,15057,15058,15061],{},[221,15059,15060],{},"Avant l'installation :"," Demande de raccordement \u002F augmentation de capacité auprès du GRD (souvent nécessaire pour installations > 5 kVA).",[714,15063,15064,15067],{},[221,15065,15066],{},"Après l'installation :"," Soumettre la déclaration de conformité de l'installateur.",[714,15069,15070,15073],{},[221,15071,15072],{},"Contrôle RGIE :"," Par un organisme de contrôle agréé (par ex. BTV, Vinçotte, AIB).",[714,15075,15076,15079],{},[221,15077,15078],{},"Changement de compteur :"," Passage au compteur bidirectionnel (numérique).",[714,15081,15082,15085],{},[221,15083,15084],{},"Activation :"," Le GRD autorise l'injection.",[5686,15087,15089],{"id":15088},"documents-requis","Documents requis",[711,15091,15092,15095,15097,15100,15108,15111],{},[714,15093,15094],{},"Schéma unifilaire (avec installation PV)",[714,15096,6995],{},[714,15098,15099],{},"Fiche technique des modules PV",[714,15101,15102,15103,15105,15106,306],{},"Fiche technique de l'onduleur – l'onduleur doit figurer sur la liste Synergrid C10\u002F26, vérifiable avec la ",[203,15104,7754],{"href":7412}," (contexte : ",[203,15107,15003],{"href":15002},[714,15109,15110],{},"Déclaration de conformité de l'installateur",[714,15112,15113],{},"Rapport de contrôle RGIE",[5686,15115,15117],{"id":15116},"délais","Délais",[711,15119,15120,15130,15139],{},[714,15121,15122,15125,15126,15129],{},[221,15123,15124],{},"Fluvius (Flandre) :"," Déclaration dans les ",[221,15127,15128],{},"30 jours"," après la mise en service.",[714,15131,15132,15135,15136,15138],{},[221,15133,15134],{},"ORES (Wallonie) :"," Déclaration ",[221,15137,10691],{}," la mise en service recommandée.",[714,15140,15141,15144],{},[221,15142,15143],{},"Sibelga (Bruxelles) :"," Pré-déclaration pour installations > 5 kVA.",[7849,15146],{},[12,15148,15150],{"id":15149},"autoconsommation-vs-injection","Autoconsommation vs. injection",[5686,15152,15154],{"id":15153},"flandre-compteur-numérique","Flandre : Compteur numérique",[17,15156,15157,15158,15161],{},"Depuis 2021, tous les compteurs analogiques en Flandre sont progressivement remplacés par des ",[221,15159,15160],{},"compteurs numériques",". Le compteur numérique mesure la consommation et l'injection séparément :",[711,15163,15164,15170,15176],{},[714,15165,15166,15169],{},[221,15167,15168],{},"L'autoconsommation"," est directement déduite (pas de frais de réseau).",[714,15171,15172,15175],{},[221,15173,15174],{},"L'injection"," est rémunérée au prix du marché actuel (tarif d'injection).",[714,15177,15178,15181],{},[221,15179,15180],{},"Le prélèvement réseau"," est facturé au tarif normal.",[9883,15183,15184],{},[17,15185,15186,15188],{},[221,15187,14912],{}," Maximisez l'autoconsommation grâce à une gestion intelligente (pompe à chaleur, boiler, borne de recharge pendant la journée).",[5686,15190,15192],{"id":15191},"wallonie-tarif-prosommateur","Wallonie : Tarif prosommateur",[17,15194,15195,15196,15199],{},"En Wallonie, depuis 2024, le ",[221,15197,15198],{},"tarif prosommateur"," s'applique :",[711,15201,15202,15209,15212],{},[714,15203,15204,15205,15208],{},"Compensation entre injection et consommation sur ",[221,15206,15207],{},"base annuelle"," (encore jusqu'à fin 2030).",[714,15210,15211],{},"À partir de 2031, transition progressive vers la mesure en temps réel.",[714,15213,15214,15215,212],{},"Les frais de réseau sont calculés sur la base de la ",[221,15216,15217],{},"consommation annuelle",[5686,15219,12999],{"id":12998},[711,15221,15222,15228],{},[714,15223,15224,15227],{},[221,15225,15226],{},"Système de certificats verts"," : Certificats verts par MWh produit.",[714,15229,15230],{},"Compensation via le compteur possible (selon le type de compteur).",[7849,15232],{},[12,15234,15236],{"id":15235},"intégration-de-batterie-dans-le-schéma","Intégration de batterie dans le schéma",[17,15238,15239],{},"Si vous ajoutez un stockage par batterie, le schéma s'enrichit :",[5686,15241,15243],{"id":15242},"composants-supplémentaires","Composants supplémentaires",[5508,15245,15248],{"className":15246,"code":15247,"language":5513},[5511],"Onduleur (onduleur hybride)\n   │\n   ├── Sortie AC → Tableau principal (comme ci-dessus)\n   │\n   └── Raccordement batterie DC\n         │\n         ├── Sectionneur batterie (DC)\n         │\n         ├── BMS (Système de Gestion de Batterie, interne)\n         │\n         └── Stockage batterie (par ex. 10 kWh LFP)\n",[4068,15249,15247],{"__ignoreMap":1212},[5686,15251,15253],{"id":15252},"commutation-de-secours-optionnel","Commutation de secours (optionnel)",[17,15255,15256],{},"Pour un système capable de fournir du courant de secours :",[711,15258,15259,15264,15270],{},[714,15260,15261,15263],{},[221,15262,12681],{}," (automatique ou manuel) : isole la maison du réseau et l'alimente depuis la batterie.",[714,15265,15266,15267,212],{},"Doit être dessiné dans le schéma unifilaire comme ",[221,15268,15269],{},"commutateur",[714,15271,15272],{},"Les circuits de secours doivent être identifiés.",[9883,15274,15275],{},[17,15276,15277,15280,15281,15284],{},[221,15278,15279],{},"Prescription RGIE :"," Pour les systèmes de secours, il faut garantir qu'",[221,15282,15283],{},"aucune réinjection dans le réseau"," n'a lieu lorsque le réseau est coupé (protection anti-îlotage).",[7849,15286],{},[12,15288,15290],{"id":15289},"règles-spéciales-rgie-pour-le-pv-art-7112","Règles spéciales RGIE pour le PV (Art. 7.112)",[17,15292,15293,15294,15297,15298,15301],{},"Le RGIE consacre une section propre aux installations photovoltaïques domestiques à basse tension ",[221,15295,15296],{},"jusqu'à 10 kVA"," — ",[221,15299,15300],{},"Art. 7.112"," (ces règles spéciales ne s'appliquent pas aux installations > 10 kVA). Les mesures particulières prévues à l'Art. 7.112.2 sont : la mise à disposition de la documentation visée à la Section 9.1.2, l'identification des conducteurs à courant continu et des conducteurs actifs à courant alternatif, les panneaux d'avertissement (« Ne pas couper en charge » \u002F « L'installation électrique est toujours sous tension ») et la mise à la terre des cadres des modules. En complément, il existe d'autres bonnes pratiques et exigences des fabricants\u002FGRD :",[21,15303,15304,15316],{},[24,15305,15306],{},[27,15307,15308,15310,15313],{},[30,15309,423],{},[30,15311,15312],{},"Détails",[30,15314,15315],{},"Base",[43,15317,15318,15331,15343,15355,15367,15380,15392,15405],{},[27,15319,15320,15325,15328],{},[48,15321,15322],{},[221,15323,15324],{},"Identification conducteurs",[48,15326,15327],{},"Identifier les conducteurs à courant continu et les conducteurs actifs à courant alternatif",[48,15329,15330],{},"Art. 7.112.2",[27,15332,15333,15338,15341],{},[48,15334,15335],{},[221,15336,15337],{},"Panneaux d'avertissement",[48,15339,15340],{},"« Ne pas couper en charge » et « L'installation électrique est toujours sous tension » (ou équiv.)",[48,15342,15330],{},[27,15344,15345,15350,15353],{},[48,15346,15347],{},[221,15348,15349],{},"Mise à la terre des cadres",[48,15351,15352],{},"Conducteur de protection ≥ 2,5 mm² (avec) ou ≥ 4 mm² (sans protection mécanique)",[48,15354,15330],{},[27,15356,15357,15361,15364],{},[48,15358,15359],{},[221,15360,14671],{},[48,15362,15363],{},"Facilement accessible, clairement identifié",[48,15365,15366],{},"Bonne pratique \u002F fabricant",[27,15368,15369,15374,15377],{},[48,15370,15371],{},[221,15372,15373],{},"Cheminement câbles DC",[48,15375,15376],{},"Séparer des câbles AC (goulotte\u002Ftube dédié)",[48,15378,15379],{},"Bonne pratique \u002F CEI",[27,15381,15382,15387,15390],{},[48,15383,15384],{},[221,15385,15386],{},"Classe de protection câble",[48,15388,15389],{},"Câble DC min. classe II (double isolation)",[48,15391,15379],{},[27,15393,15394,15399,15402],{},[48,15395,15396],{},[221,15397,15398],{},"Protection foudre",[48,15400,15401],{},"Pour bâtiments avec paratonnerre : intégrer le PV dans le concept de protection foudre",[48,15403,15404],{},"Bonne pratique",[27,15406,15407,15412,15415],{},[48,15408,15409],{},[221,15410,15411],{},"Fixation toiture",[48,15413,15414],{},"Pas de prescription RGIE, mais droit de la construction (charge vent, statique)",[48,15416,15417],{},"Droit de la construction",[5686,15419,15421],{"id":15420},"signalisation-sur-le-bâtiment","Signalisation sur le bâtiment",[17,15423,15424,15425,15428],{},"Selon le RGIE, un ",[221,15426,15427],{},"panneau d'avertissement"," doit être apposé sur le bâtiment indiquant la présence de l'installation PV :",[711,15430,15431,15438,15443],{},[714,15432,15433,15434,15437],{},"Au ",[221,15435,15436],{},"coffret de comptage"," ou tableau principal",[714,15439,15433,15440],{},[221,15441,15442],{},"sectionneur DC",[714,15444,15445,15446,15449],{},"À l'",[221,15447,15448],{},"entrée du bâtiment"," (information pompiers)",[17,15451,15452,15453],{},"Texte : ",[60,15454,15455],{},"« Attention : Installation photovoltaïque. Une tension DC peut être présente même lorsque le réseau est coupé. »",[7849,15457],{},[12,15459,15461],{"id":15460},"planelec-pv-dans-le-schéma-unifilaire","PlanElec : PV dans le schéma unifilaire",[17,15463,15464],{},"Avec PlanElec, vous pouvez documenter votre installation PV directement dans le schéma unifilaire :",[711,15466,15467,15470,15473,15476],{},[714,15468,15469],{},"Ajouter les modules PV comme source",[714,15471,15472],{},"Placer l'onduleur et les dispositifs de protection",[714,15474,15475],{},"Auto-contrôle assisté pour les protections et données saisies",[714,15477,15478],{},"Export PDF pour examen ultérieur par un professionnel, le GRD ou l'organisme de contrôle",[7849,15480],{},[12,15482,10024],{"id":10023},[711,15484,15485,15490,15495,15499],{},[714,15486,15487],{},[203,15488,15489],{"href":3283},"Créer un schéma unifilaire en Belgique",[714,15491,15492],{},[203,15493,15494],{"href":567},"Planifier un tableau électrique : Conception et dimensionnement",[714,15496,15497],{},[203,15498,11726],{"href":1579},[714,15500,15501],{},[203,15502,7847],{"href":6216},[7849,15504],{},[17,15506,15507],{},[60,15508,15509,15510,15512,15513],{},"Documentez l'onduleur, les protections et le stockage batterie avec ",[221,15511,5823],{}," dans le schéma unifilaire. L'auto-contrôle est indicatif ; faites vérifier les documents avant leur remise. ",[203,15514,11742],{"href":7861},[12,15516,15518],{"id":15517},"revue-finale-avant-contrôle-et-déclaration","Revue finale avant contrôle et déclaration",[17,15520,15521],{},"Figez la configuration réellement installée. Relevez références exactes des modules, onduleur et stockage, firmware mentionné par l'homologation, valeurs AC\u002FDC, chaînes, protections, sectionnements, types et trajets de câbles. Un devis ou une brochure de gamme ne prouve pas le matériel posé. Les photos d'étiquettes améliorent la traçabilité sans remplacer schémas et déclarations.",[17,15523,15524,15525,15529],{},"Comparez la désignation et les restrictions avec la ",[203,15526,15528],{"href":6589,"rel":15527},[5373],"page officielle C10\u002F26 de Synergrid",". L'inscription porte sur le type d'interface réseau ; elle n'approuve ni l'installation complète, ni les câbles, ni le dossier RGIE. En cas d'ambiguïté, interrogez fabricant, importateur et gestionnaire plutôt que de choisir un nom voisin.",[17,15531,15532],{},"Rapprochez schéma unifilaire, plan de position et exécution. L'organisme agréé contrôle l'installation électrique ; le gestionnaire applique sa procédure de déclaration et de raccordement. Un rapport de contrôle n'est donc pas une autorisation réseau, et une référence C10\u002F26 n'est pas une réussite au contrôle. Après remplacement d'onduleur, ajout de chaînes, batterie ou modification des protections, conservez l'ancienne version et datez le nouvel état conforme à l'exécution. La base officielle reste le Livre 1 V06, chapitre 7.112 et partie 9, complété par la notice actuelle du matériel.",{"title":1212,"searchDepth":1213,"depth":1213,"links":15534},[15535,15536,15540,15545,15546,15552,15557,15561,15564,15565,15566],{"id":14565,"depth":1213,"text":14566},{"id":14610,"depth":1213,"text":14611,"children":15537},[15538,15539],{"id":14617,"depth":5848,"text":14618},{"id":14627,"depth":5848,"text":14628},{"id":14713,"depth":1213,"text":14714,"children":15541},[15542,15543,15544],{"id":14717,"depth":5848,"text":14718},{"id":14791,"depth":5848,"text":14792},{"id":14847,"depth":5848,"text":14848},{"id":14922,"depth":1213,"text":14923},{"id":12704,"depth":1213,"text":7459,"children":15547},[15548,15549,15550,15551],{"id":15010,"depth":5848,"text":15011},{"id":15052,"depth":5848,"text":15053},{"id":15088,"depth":5848,"text":15089},{"id":15116,"depth":5848,"text":15117},{"id":15149,"depth":1213,"text":15150,"children":15553},[15554,15555,15556],{"id":15153,"depth":5848,"text":15154},{"id":15191,"depth":5848,"text":15192},{"id":12998,"depth":5848,"text":12999},{"id":15235,"depth":1213,"text":15236,"children":15558},[15559,15560],{"id":15242,"depth":5848,"text":15243},{"id":15252,"depth":5848,"text":15253},{"id":15289,"depth":1213,"text":15290,"children":15562},[15563],{"id":15420,"depth":5848,"text":15421},{"id":15460,"depth":1213,"text":15461},{"id":10023,"depth":1213,"text":10024},{"id":15517,"depth":1213,"text":15518},"2026-04-21","Guide complet pour la documentation d'une installation PV dans le schéma unifilaire. Dispositifs de protection, déclaration au GRD, intégration batterie et RGIE Art. 7.112.",{},"\u002Fblog\u002Fpv-system-documentation.fr",{"title":14554,"description":15568},"panneaux-solaires-schema","blog\u002Fpv-system-documentation.fr",[15575,7928,1248,1242,7927,15576,15577,9280],"PV","gestionnaire de réseau","batterie","DjYvx6rBCNyaD6UiJd_YXw9BFidcfM8H24gCUoM7FQ0",{"id":15580,"title":15581,"articleId":15582,"body":15583,"category":1228,"date":16428,"description":16429,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":16430,"navigation":1234,"path":16431,"publishDate":16428,"readTime":8416,"refreshInterval":1237,"seo":16432,"slug":16433,"stem":16434,"tags":16435,"__hash__":16438},"blog\u002Fblog\u002Fold-building-arei-part8.fr.md","Ancien bâtiment et RGIE Partie 8 : Règles spéciales pour les installations existantes","old-building-arei-part8",{"type":9,"value":15584,"toc":16390},[15585,15592,15594,15598,15605,15616,15623,15625,15629,15636,15640,15643,15647,15654,15658,15684,15692,15694,15698,15701,15705,15743,15747,15783,15795,15799,15802,15831,15835,15841,15845,15866,15870,15873,15875,15879,15886,15890,15982,15986,15989,16015,16017,16021,16025,16028,16032,16039,16051,16055,16125,16136,16138,16142,16148,16152,16159,16179,16183,16201,16203,16207,16214,16218,16232,16236,16247,16251,16262,16266,16269,16273,16327,16329,16331,16353,16355,16366,16370,16373,16376,16379,16387],[17,15586,15587,15588,15591],{},"Toute installation électrique en Belgique ne doit pas forcément répondre aux dernières prescriptions du RGIE. Pour les bâtiments plus anciens, la ",[221,15589,15590],{},"Partie 8"," constitue un ensemble de règles spécifiques qui tolère certaines dérogations par rapport au standard actuel — tant qu'il n'existe pas de danger immédiat. Cet article explique quand la Partie 8 s'applique, ce qui est autorisé et où se trouvent les limites.",[7849,15593],{},[12,15595,15597],{"id":15596},"quest-ce-que-la-partie-8","Qu'est-ce que la Partie 8 ?",[17,15599,15600,15601,15604],{},"La Partie 8 du RGIE (Règlement Général sur les Installations Électriques) est une ",[221,15602,15603],{},"réglementation spéciale pour les installations existantes"," qui ont été réalisées et réceptionnées avant l'entrée en vigueur du RGIE actuel.",[17,15606,15607,15608,15611,15612,15615],{},"Le principe de base : tant qu'une installation fonctionne de manière ",[221,15609,15610],{},"sûre"," et ne représente ",[221,15613,15614],{},"aucun danger immédiat",", elle n'a pas à être entièrement mise aux normes actuelles — même si elle ne répond pas à toutes les prescriptions en vigueur.",[9883,15617,15618],{},[17,15619,15620,15622],{},[221,15621,13530],{}," La Partie 8 n'est pas un blanc-seing. Elle définit clairement quelles dérogations sont tolérées et lesquelles ne le sont pas.",[7849,15624],{},[12,15626,15628],{"id":15627},"quand-la-partie-8-sapplique-t-elle","Quand la Partie 8 s'applique-t-elle ?",[17,15630,15631,15632,15635],{},"La Partie 8 s'applique aux installations qui remplissent ",[221,15633,15634],{},"l'une"," des conditions suivantes :",[5686,15637,15639],{"id":15638},"condition-1-installation-avant-le-01101981","Condition 1 : Installation avant le 01.10.1981",[17,15641,15642],{},"Les installations réalisées avant le 1er octobre 1981 (date d'entrée en vigueur du RGIE original) tombent en principe sous la Partie 8.",[5686,15644,15646],{"id":15645},"condition-2-réceptionnée-sous-lancien-rgie","Condition 2 : Réceptionnée sous l'ancien RGIE",[17,15648,15649,15650,15653],{},"Les installations qui ont été réceptionnées sous une version antérieure du RGIE et qui n'ont ",[221,15651,15652],{},"pas été substantiellement modifiées"," depuis la dernière réception.",[5686,15655,15657],{"id":15656},"quest-ce-quune-modification-substantielle","Qu'est-ce qu'une « modification substantielle » ?",[711,15659,15660,15666,15672,15678],{},[714,15661,15662,15663],{},"Ajout de ",[221,15664,15665],{},"nouveaux circuits",[714,15667,15668,15669],{},"Extension du ",[221,15670,15671],{},"tableau de distribution",[714,15673,15674,15675],{},"Modification de l'",[221,15676,15677],{},"installation de comptage",[714,15679,15680,15683],{},[221,15681,15682],{},"Recâblage"," important",[9883,15685,15686],{},[17,15687,15688,15691],{},[221,15689,15690],{},"Attention :"," Les petites modifications comme le remplacement d'une prise ou d'un interrupteur ne comptent PAS comme modification substantielle.",[7849,15693],{},[12,15695,15697],{"id":15696},"ce-qui-est-autorisé-sous-la-partie-8-dérogations-tolérées","Ce qui est autorisé sous la Partie 8 (Dérogations tolérées)",[17,15699,15700],{},"Les points suivants s'écartent du RGIE actuel, mais sont tolérés sous la Partie 8 lors du contrôle :",[5686,15702,15704],{"id":15703},"_1-anciens-types-de-câbles","1. Anciens types de câbles",[21,15706,15707,15717],{},[24,15708,15709],{},[27,15710,15711,15714],{},[30,15712,15713],{},"RGIE actuel",[30,15715,15716],{},"Partie 8 tolère",[43,15718,15719,15727,15735],{},[27,15720,15721,15724],{},[48,15722,15723],{},"XVB \u002F VOBst en Preflex",[48,15725,15726],{},"Câbles VOB dans d'anciennes gaines",[27,15728,15729,15732],{},[48,15730,15731],{},"Classe de réaction au feu Cca",[48,15733,15734],{},"Types de câbles plus anciens sans classification CPR",[27,15736,15737,15740],{},[48,15738,15739],{},"Section minimale 2,5 mm² pour les prises",[48,15741,15742],{},"Minimum 1 mm² avec fusible max. 6 A ou disjoncteur max. 10 A (Art. 8.2.1 Nr. 5)",[5686,15744,15746],{"id":15745},"_2-différentiels-rcd","2. Différentiels (RCD)",[21,15748,15749,15757],{},[24,15750,15751],{},[27,15752,15753,15755],{},[30,15754,15713],{},[30,15756,15716],{},[43,15758,15759,15767,15775],{},[27,15760,15761,15764],{},[48,15762,15763],{},"Différentiel 30 mA par circuit prises",[48,15765,15766],{},"Pas de 30 mA nécessaire (seulement 300 mA principal)",[27,15768,15769,15772],{},[48,15770,15771],{},"Différentiel 30 mA obligatoire pour salle de bain",[48,15773,15774],{},"Reste obligatoire (non couvert par la dérogation Partie 8, Art. 4.2.4.3 b N° 3 \u002F Art. 7.1.4.3)",[27,15776,15777,15780],{},[48,15778,15779],{},"Max. 8 circuits par RCD",[48,15781,15782],{},"Plus de circuits autorisés",[9883,15784,15785],{},[17,15786,15787,15790,15791,15794],{},[221,15788,15789],{},"Note :"," Même sous la Partie 8, un ",[221,15792,15793],{},"différentiel principal 300 mA"," est recommandé et souvent exigé par le gestionnaire de réseau lors d'une nouvelle installation de compteur.",[5686,15796,15798],{"id":15797},"_3-prises-sans-contact-de-terre","3. Prises sans contact de terre",[17,15800,15801],{},"Les anciennes prises (type C, sans broche de terre) sont tolérées sous la Partie 8, à condition que :",[711,15803,15804,15811,15818,15828],{},[714,15805,15806,15807,15810],{},"La prise soit protégée par un ",[221,15808,15809],{},"différentiel à haute ou très haute sensibilité"," (max. 30 mA) (Art. 8.2.1 N° 6 lettre b).",[714,15812,15813,15814,15817],{},"Aucun appareil de ",[221,15815,15816],{},"classe de protection I"," (avec boîtier métallique) ne soit branché.",[714,15819,15820,15821,15824,15825,212],{},"La prise ne soit pas dans la ",[221,15822,15823],{},"salle de bain"," ou dans un ",[221,15826,15827],{},"lieu humide",[714,15829,15830],{},"Le circuit soit par ailleurs intact.",[5686,15832,15834],{"id":15833},"_4-pas-de-parafoudre-spd","4. Pas de parafoudre (SPD)",[17,15836,15837,15838,212],{},"Le RGIE actuel prescrit un parafoudre (SPD) Type 2 pour les nouvelles installations. Sous la Partie 8, ce n'est ",[221,15839,15840],{},"pas requis",[5686,15842,15844],{"id":15843},"_5-ancienne-technique-de-distribution","5. Ancienne technique de distribution",[711,15846,15847,15853,15859],{},[714,15848,4251,15849,15852],{},[221,15850,15851],{},"fusibles"," au lieu de disjoncteurs sont autorisés.",[714,15854,4251,15855,15858],{},[221,15856,15857],{},"fusibles à vis"," (Diazed) sont tolérés.",[714,15860,15861,15862,15865],{},"L'absence d'",[221,15863,15864],{},"étiquetage"," est mentionnée comme défaut, mais n'entraîne pas un échec.",[5686,15867,15869],{"id":15868},"_6-pas-de-classification-de-réaction-au-feu-des-câbles","6. Pas de classification de réaction au feu des câbles",[17,15871,15872],{},"Les câbles sans classification CPR (installés avant 2017) sont tolérés, car le règlement CPR ne s'applique qu'à partir de juillet 2017 pour les nouvelles installations.",[7849,15874],{},[12,15876,15878],{"id":15877},"ce-qui-nest-pas-autorisé-même-sous-la-partie-8","Ce qui n'est PAS autorisé (même sous la Partie 8)",[17,15880,15881,15882,15885],{},"Certaines situations ne sont ",[221,15883,15884],{},"jamais tolérées",", quel que soit l'âge de l'installation :",[5686,15887,15889],{"id":15888},"absolument-inadmissible","Absolument inadmissible :",[21,15891,15892,15900],{},[24,15893,15894],{},[27,15895,15896,15898],{},[30,15897,3379],{},[30,15899,14863],{},[43,15901,15902,15912,15922,15932,15942,15952,15962,15972],{},[27,15903,15904,15909],{},[48,15905,15906],{},[221,15907,15908],{},"Câbles dénudés ou endommagés",[48,15910,15911],{},"Danger immédiat d'électrocution",[27,15913,15914,15919],{},[48,15915,15916],{},[221,15917,15918],{},"Absence totale de mise à la terre",[48,15920,15921],{},"Pas de protection en cas de défaut d'isolement",[27,15923,15924,15929],{},[48,15925,15926],{},[221,15927,15928],{},"Eau en contact avec l'électricité",[48,15930,15931],{},"Danger de mort",[27,15933,15934,15939],{},[48,15935,15936],{},[221,15937,15938],{},"Parties sous tension accessibles",[48,15940,15941],{},"Risque de contact direct",[27,15943,15944,15949],{},[48,15945,15946],{},[221,15947,15948],{},"Câbles ou connexions en surchauffe",[48,15950,15951],{},"Risque d'incendie",[27,15953,15954,15959],{},[48,15955,15956],{},[221,15957,15958],{},"Connexions desserrées dans les boîtes de dérivation",[48,15960,15961],{},"Risque d'arc\u002Fincendie",[27,15963,15964,15969],{},[48,15965,15966],{},[221,15967,15968],{},"Boîtes de dérivation sans couvercle",[48,15970,15971],{},"Protection contre les contacts manquante",[27,15973,15974,15979],{},[48,15975,15976],{},[221,15977,15978],{},"Prise de salle de bain en zone 0 ou 1",[48,15980,15981],{},"Danger de mort, interdit même sous Partie 8",[5686,15983,15985],{"id":15984},"exigences-minimales-de-sécurité","Exigences minimales de sécurité :",[17,15987,15988],{},"Même sous la Partie 8, il faut garantir :",[711,15990,15991,15997,16003,16009],{},[714,15992,15993,15996],{},[221,15994,15995],{},"Section suffisante"," pour la charge réelle (pas de câble 0,75 mm² surchargé).",[714,15998,15999,16002],{},[221,16000,16001],{},"Fusibles fonctionnels"," (pas de fusibles « pontés »).",[714,16004,16005,16008],{},[221,16006,16007],{},"Mise à la terre du tableau principal"," (connexion à l'électrode de terre).",[714,16010,16011,16014],{},[221,16012,16013],{},"Accessibilité"," du tableau de distribution.",[7849,16016],{},[12,16018,16020],{"id":16019},"contrôle-périodique","Contrôle périodique",[5686,16022,16024],{"id":16023},"la-périodicité-dépend-de-lhistorique","La périodicité dépend de l'historique",[17,16026,16027],{},"Dire que toute ancienne installation est contrôlée automatiquement tous les 25 ans est trop général. Le SPF Économie distingue les installations déjà contrôlées sous le RGIE et les anciennes installations d'avant le 1er octobre 1981 sans cet historique. Vente, modification ou extension importante, renforcement et conditions d'un rapport antérieur peuvent entraîner des visites et délais différents. Vérifiez le cas officiel et le dernier rapport.",[5686,16029,16031],{"id":16030},"lors-dun-changement-de-propriétaire","Lors d'un changement de propriétaire",[17,16033,16034,16035,16038],{},"Lors de la ",[221,16036,16037],{},"vente d'un bien immobilier",", une attestation de contrôle valide (de moins de 25 ans) est obligatoire. Si elle n'existe pas, un contrôle doit être effectué avant la vente.",[9883,16040,16041],{},[17,16042,16043,16046,16047,16050],{},[221,16044,16045],{},"Délai de 18 mois (Art. 8.4.2.2) :"," Lors de l'achat d'un bien immobilier avec un rapport de contrôle négatif, l'acheteur dispose de ",[221,16048,16049],{},"18 mois"," à compter de la date d'achat pour remédier aux défauts et faire effectuer un recontrôle.",[5686,16052,16054],{"id":16053},"que-vérifie-t-on-lors-du-contrôle-périodique","Que vérifie-t-on lors du contrôle périodique ?",[21,16056,16057,16067],{},[24,16058,16059],{},[27,16060,16061,16064],{},[30,16062,16063],{},"Point de contrôle",[30,16065,16066],{},"Évaluation",[43,16068,16069,16077,16085,16093,16101,16109,16117],{},[27,16070,16071,16074],{},[48,16072,16073],{},"Inspection visuelle des câbles et connexions",[48,16075,16076],{},"Dommages, surchauffe",[27,16078,16079,16082],{},[48,16080,16081],{},"Mesure de la résistance de terre",[48,16083,16084],{},"≤ 30 Ω (seuil réglementaire selon Art. 4.2.4.3b ; au-delà, des mesures de protection supplémentaires sont nécessaires)",[27,16086,16087,16090],{},[48,16088,16089],{},"Mesure de la résistance d'isolement",[48,16091,16092],{},"> 0,5 MΩ",[27,16094,16095,16098],{},[48,16096,16097],{},"Test RCD (si présent)",[48,16099,16100],{},"Temps et courant de déclenchement",[27,16102,16103,16106],{},[48,16104,16105],{},"Vérification de la protection contre les courts-circuits",[48,16107,16108],{},"Fusibles \u002F disjoncteurs présents",[27,16110,16111,16114],{},[48,16112,16113],{},"Protection contre les contacts directs",[48,16115,16116],{},"Couvercles, protection IP",[27,16118,16119,16122],{},[48,16120,16121],{},"Documentation",[48,16123,16124],{},"Schéma unifilaire + plan de situation présents ?",[9883,16126,16127],{},[17,16128,16129,15790,16131,11213,16133,16135],{},[221,16130,15789],{},[221,16132,1248],{},[221,16134,8422],{}," doivent être disponibles — même s'ils doivent être établis rétroactivement.",[7849,16137],{},[12,16139,16141],{"id":16140},"la-règle-de-contamination-lors-dune-rénovation-partielle","La règle de contamination lors d'une rénovation partielle",[17,16143,16144,16145,212],{},"Un aspect particulièrement important pour les anciens bâtiments : la ",[221,16146,16147],{},"règle de contamination",[5686,16149,16151],{"id":16150},"comment-fonctionne-t-elle","Comment fonctionne-t-elle ?",[17,16153,16154,16155,16158],{},"Lorsque vous modifiez ",[221,16156,16157],{},"substantiellement"," une partie de votre installation (par ex. ajout de nouveaux circuits) :",[5034,16160,16161,16167,16173],{},[714,16162,1759,16163,16166],{},[221,16164,16165],{},"nouvelle partie"," doit entièrement répondre au RGIE actuel.",[714,16168,1759,16169,16172],{},[221,16170,16171],{},"partie existante"," continue d'être évaluée selon la Partie 8.",[714,16174,16175,16178],{},[221,16176,16177],{},"MAIS :"," Si la nouvelle partie « contamine » la partie existante (par ex. nouveaux câbles dans le même tableau), le contrôleur peut décider que l'ensemble du tableau doit répondre au RGIE actuel.",[5686,16180,16182],{"id":16181},"conséquences-pratiques","Conséquences pratiques :",[711,16184,16185,16191,16198],{},[714,16186,16187,16188,212],{},"Planifiez les rénovations de manière à ce que les parties nouvelles et anciennes soient ",[221,16189,16190],{},"clairement séparées",[714,16192,16193,16194,16197],{},"Idéalement, un ",[221,16195,16196],{},"sous-tableau séparé"," pour les nouveaux circuits.",[714,16199,16200],{},"Documentez précisément ce qui est ancien et ce qui est nouveau.",[7849,16202],{},[12,16204,16206],{"id":16205},"recommandation-modernisation-progressive","Recommandation : Modernisation progressive",[17,16208,16209,16210,16213],{},"Même si la Partie 8 tolère des dérogations, une ",[221,16211,16212],{},"modernisation progressive"," est recommandée :",[5686,16215,16217],{"id":16216},"priorité-1-critique-pour-la-sécurité","Priorité 1 (Critique pour la sécurité)",[711,16219,16220,16223,16226,16229],{},[714,16221,16222],{},"Installer un différentiel principal 300 mA (s'il est absent)",[714,16224,16225],{},"Remplacer les câbles endommagés",[714,16227,16228],{},"Réparer les connexions desserrées",[714,16230,16231],{},"Vérifier et améliorer la mise à la terre si nécessaire",[5686,16233,16235],{"id":16234},"priorité-2-recommandé","Priorité 2 (Recommandé)",[711,16237,16238,16241,16244],{},[714,16239,16240],{},"Différentiels de groupe 30 mA pour salle de bain et cuisine",[714,16242,16243],{},"Remplacer les anciens fusibles par des disjoncteurs",[714,16245,16246],{},"Installer un parafoudre Type 2",[5686,16248,16250],{"id":16249},"priorité-3-confort-pérennité","Priorité 3 (Confort + pérennité)",[711,16252,16253,16256,16259],{},[714,16254,16255],{},"Moderniser le tableau (plus de rangées, étiquetage)",[714,16257,16258],{},"Installer des prises avec terre",[714,16260,16261],{},"Préparation pour borne de recharge \u002F installation PV",[5686,16263,16265],{"id":16264},"définir-les-travaux-avant-de-chiffrer","Définir les travaux avant de chiffrer",[17,16267,16268],{},"Une fourchette générique en ligne n'est pas un budget fiable. Faites inventorier l'installation, séparez les défauts de sécurité des améliorations facultatives et demandez une offre datée pour le bâtiment réel. Tracés, finitions, accès, état du tableau et ampleur de rénovation modifient fortement le travail.",[12,16270,16272],{"id":16271},"résumé","Résumé",[21,16274,16275,16285],{},[24,16276,16277],{},[27,16278,16279,16282],{},[30,16280,16281],{},"Question",[30,16283,16284],{},"Réponse",[43,16286,16287,16295,16303,16311,16319],{},[27,16288,16289,16292],{},[48,16290,16291],{},"Mon ancien bâtiment doit-il répondre au RGIE actuel ?",[48,16293,16294],{},"Pas entièrement, la Partie 8 autorise des dérogations",[27,16296,16297,16300],{},[48,16298,16299],{},"Ai-je besoin d'un différentiel 30 mA ?",[48,16301,16302],{},"Pas obligatoire sous Partie 8, mais fortement recommandé",[27,16304,16305,16308],{},[48,16306,16307],{},"Les anciennes prises sans terre sont-elles autorisées ?",[48,16309,16310],{},"Sous conditions oui (pas de salle de bain, pas d'appareils classe I)",[27,16312,16313,16316],{},[48,16314,16315],{},"À quelle fréquence faut-il contrôler ?",[48,16317,16318],{},"Selon l'historique et le motif ; la vente suit son cas précis",[27,16320,16321,16324],{},[48,16322,16323],{},"Que se passe-t-il en cas de rénovation partielle ?",[48,16325,16326],{},"Nouvelle partie = RGIE actuel, ancienne = Partie 8 (règle de contamination)",[7849,16328],{},[12,16330,10024],{"id":10023},[711,16332,16333,16338,16344,16349],{},[714,16334,16335],{},[203,16336,16337],{"href":6216},"Contrôle électrique en Belgique : Que vérifie-t-on ?",[714,16339,16340],{},[203,16341,16343],{"href":16342},"\u002Ffr\u002Fblog\u002Frgie-2026-changements","Que change le RGIE 2026 ?",[714,16345,16346],{},[203,16347,16348],{"href":1551},"Preflex vs. pose libre",[714,16350,16351],{},[203,16352,568],{"href":567},[7849,16354],{},[17,16356,16357],{},[60,16358,16359,16360,16362,16363],{},"Même pour les anciens bâtiments, ",[221,16361,5823],{}," aide à construire numériquement le schéma unifilaire et le plan de situation. L'auto-contrôle est indicatif ; faites vérifier les documents et les dérogations applicables par un professionnel. ",[203,16364,16365],{"href":7861},"Commencer gratuitement →",[12,16367,16369],{"id":16368},"établir-lhistorique-avant-dinvoquer-une-dérogation","Établir l'historique avant d'invoquer une dérogation",[17,16371,16372],{},"L'âge du bâtiment ne suffit pas. Constituez une chronologie à partir des rapports, étiquettes de tableau, factures, permis et éléments visibles. Identifiez les parties antérieures au 1er octobre 1981, les modifications ou extensions ultérieures et leur éventuel contrôle de conformité. La partie 8 définit les anciennes installations et des dérogations précises ; elle n'exempte pas automatiquement chaque composant d'une vieille maison.",[17,16374,16375],{},"Marquez parties anciennes et nouvelles sur une copie du schéma. Pour chaque dérogation envisagée, notez la disposition V06 exacte, le circuit, la preuve d'âge et les conditions de sécurité restantes. Sans preuve, indiquez « inconnu » : couleur et aspect d'un câble ne datent pas sûrement une pose. L'organisme agréé statue sur l'application au cas réel.",[17,16377,16378],{},"N'utilisez pas la « règle de contamination » informelle comme un article du RGIE. Une modification ou extension importante est appréciée selon les dispositions actuelles applicables ; le statut de l'existant dépend des définitions, du champ et de l'historique. Un tableau ou des protections communs rendent la limite importante, mais son étendue vient du règlement et du projet, pas d'un slogan. Consultez l'organisme avant travaux si cette limite commande la rénovation.",[17,16380,16381,16382,16386],{},"Lors d'une vente, suivez la ",[203,16383,16385],{"href":11054,"rel":16384},[5373],"FAQ du SPF Économie",". Elle distingue obligations du vendeur, communication de l'acheteur et parcours de 18 mois après rapport négatif. Ce parcours ne se confond pas avec le suivi de 12 mois d'autres contrôles. Date de l'acte et type de rapport comptent.",[17,16388,16389],{},"Le dossier transmis contient schémas actuels, rapports, déclarations, notices et modifications. PlanElec aide à garder les références cohérentes sans décider l'éligibilité d'une dérogation ni couvrir tous les cas. Revue du 29 août 2026 selon le Livre 1 V06 et la page SPF du 1er avril 2026.",{"title":1212,"searchDepth":1213,"depth":1213,"links":16391},[16392,16393,16398,16406,16410,16415,16419,16425,16426,16427],{"id":15596,"depth":1213,"text":15597},{"id":15627,"depth":1213,"text":15628,"children":16394},[16395,16396,16397],{"id":15638,"depth":5848,"text":15639},{"id":15645,"depth":5848,"text":15646},{"id":15656,"depth":5848,"text":15657},{"id":15696,"depth":1213,"text":15697,"children":16399},[16400,16401,16402,16403,16404,16405],{"id":15703,"depth":5848,"text":15704},{"id":15745,"depth":5848,"text":15746},{"id":15797,"depth":5848,"text":15798},{"id":15833,"depth":5848,"text":15834},{"id":15843,"depth":5848,"text":15844},{"id":15868,"depth":5848,"text":15869},{"id":15877,"depth":1213,"text":15878,"children":16407},[16408,16409],{"id":15888,"depth":5848,"text":15889},{"id":15984,"depth":5848,"text":15985},{"id":16019,"depth":1213,"text":16020,"children":16411},[16412,16413,16414],{"id":16023,"depth":5848,"text":16024},{"id":16030,"depth":5848,"text":16031},{"id":16053,"depth":5848,"text":16054},{"id":16140,"depth":1213,"text":16141,"children":16416},[16417,16418],{"id":16150,"depth":5848,"text":16151},{"id":16181,"depth":5848,"text":16182},{"id":16205,"depth":1213,"text":16206,"children":16420},[16421,16422,16423,16424],{"id":16216,"depth":5848,"text":16217},{"id":16234,"depth":5848,"text":16235},{"id":16249,"depth":5848,"text":16250},{"id":16264,"depth":5848,"text":16265},{"id":16271,"depth":1213,"text":16272},{"id":10023,"depth":1213,"text":10024},{"id":16368,"depth":1213,"text":16369},"2026-04-14","Ce qui s'applique aux anciennes installations électriques en Belgique. RGIE Partie 8 expliqué : dérogations autorisées, contrôle périodique et conseils pour une modernisation progressive.",{},"\u002Fblog\u002Fold-building-arei-part8.fr",{"title":15581,"description":16429},"ancien-rgie-part-8","blog\u002Fold-building-arei-part8.fr",[16436,1242,15590,10093,10089,14141,16437],"ancien bâtiment","périodique","Bz0szqbDbhaeeN40Eg5eez-MOaxzuNjDvXHgqEY6PkI",{"id":16440,"title":16441,"articleId":16442,"body":16443,"category":1228,"date":17688,"description":17689,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":17690,"navigation":1234,"path":17691,"publishDate":17688,"readTime":1994,"refreshInterval":1237,"seo":17692,"slug":17693,"stem":17694,"tags":17695,"__hash__":17701},"blog\u002Fblog\u002Fdistribution-board-planning.fr.md","Planifier un tableau électrique : Conception et dimensionnement selon le RGIE","distribution-board-planning",{"type":9,"value":16444,"toc":17659},[16445,16448,16450,16454,16458,16469,16473,16484,16573,16577,16580,16649,16656,16658,16662,16665,16809,16820,16822,16826,16833,16837,16843,16847,16913,16916,16919,16921,16925,16929,16936,16940,16994,16996,17000,17007,17018,17022,17033,17035,17039,17042,17046,17129,17133,17243,17247,17350,17354,17453,17458,17460,17464,17558,17560,17564,17571,17582,17589,17593,17596,17599,17602,17605,17609,17620,17622,17624,17645,17647],[17,16446,16447],{},"Le tableau de distribution (aussi coffret électrique ou tableau divisionnaire) est le cœur de toute installation électrique. C'est là que tous les circuits convergent, c'est là que se trouvent les dispositifs de protection qui protègent votre habitation et votre famille contre les dangers électriques. Une planification réfléchie permet non seulement d'économiser de l'argent, mais aussi d'éviter les problèmes lors du contrôle RGIE.",[7849,16449],{},[12,16451,16453],{"id":16452},"bases-structure-dun-tableau-de-distribution","Bases : Structure d'un tableau de distribution",[5686,16455,16457],{"id":16456},"rail-din-rail-oméga","Rail DIN (rail oméga)",[17,16459,16460,16461,16464,16465,16468],{},"Tous les modules du tableau sont encliquetés sur des ",[221,16462,16463],{},"rails DIN"," standardisés (rail oméga 35 mm selon EN 60715). Chaque rail forme une ",[221,16466,16467],{},"rangée"," dans le tableau.",[5686,16470,16472],{"id":16471},"modules-unités-de-division","Modules (unités de division)",[17,16474,16475,16476,16479,16480,16483],{},"La largeur d'un module est mesurée en ",[221,16477,16478],{},"modules"," (aussi appelés pas de 9 mm ou TE). Un module correspond à ",[221,16481,16482],{},"18 mm",". Largeurs typiques :",[21,16485,16486,16496],{},[24,16487,16488],{},[27,16489,16490,16493],{},[30,16491,16492],{},"Module",[30,16494,16495],{},"Largeur (modules)",[43,16497,16498,16506,16514,16522,16529,16537,16544,16551,16559,16566],{},[27,16499,16500,16503],{},[48,16501,16502],{},"Disjoncteur 1 pôle",[48,16504,16505],{},"1 module",[27,16507,16508,16511],{},[48,16509,16510],{},"Disjoncteur 2 pôles",[48,16512,16513],{},"2 modules",[27,16515,16516,16519],{},[48,16517,16518],{},"Disjoncteur 3 pôles",[48,16520,16521],{},"3 modules",[27,16523,16524,16527],{},[48,16525,16526],{},"Différentiel 2 pôles (30 mA \u002F 300 mA)",[48,16528,16513],{},[27,16530,16531,16534],{},[48,16532,16533],{},"Différentiel 4 pôles",[48,16535,16536],{},"4 modules",[27,16538,16539,16542],{},[48,16540,16541],{},"Interrupteur principal 2 pôles",[48,16543,16513],{},[27,16545,16546,16549],{},[48,16547,16548],{},"Interrupteur principal 4 pôles",[48,16550,16536],{},[27,16552,16553,16556],{},[48,16554,16555],{},"Parafoudre (SPD)",[48,16557,16558],{},"2–4 modules",[27,16560,16561,16564],{},[48,16562,16563],{},"Transformateur de sonnerie",[48,16565,16513],{},[27,16567,16568,16571],{},[48,16569,16570],{},"Minuterie",[48,16572,16513],{},[5686,16574,16576],{"id":16575},"dimensions-des-tableaux","Dimensions des tableaux",[17,16578,16579],{},"Les tableaux sont dimensionnés selon le nombre de rangées et de modules par rangée :",[21,16581,16582,16598],{},[24,16583,16584],{},[27,16585,16586,16589,16592,16595],{},[30,16587,16588],{},"Désignation",[30,16590,16591],{},"Rangées",[30,16593,16594],{},"Modules\u002Frangée",[30,16596,16597],{},"Total modules",[43,16599,16600,16612,16624,16636],{},[27,16601,16602,16605,16607,16610],{},[48,16603,16604],{},"1 rangée",[48,16606,4482],{},[48,16608,16609],{},"12–18",[48,16611,16609],{},[27,16613,16614,16617,16619,16621],{},[48,16615,16616],{},"2 rangées",[48,16618,4515],{},[48,16620,16609],{},[48,16622,16623],{},"24–36",[27,16625,16626,16629,16631,16633],{},[48,16627,16628],{},"3 rangées",[48,16630,4532],{},[48,16632,16609],{},[48,16634,16635],{},"36–54",[27,16637,16638,16641,16644,16646],{},[48,16639,16640],{},"4 rangées",[48,16642,16643],{},"4",[48,16645,16609],{},[48,16647,16648],{},"48–72",[9883,16650,16651],{},[17,16652,16653],{},[221,16654,16655],{},"Pour une maison unifamiliale typique, nous recommandons au minimum un tableau 4 rangées avec 18 modules par rangée (72 modules au total).",[7849,16657],{},[12,16659,16661],{"id":16660},"étape-1-compter-les-circuits","Étape 1 : Compter les circuits",[17,16663,16664],{},"Listez tous les circuits nécessaires. Pour une maison unifamiliale moyenne (3 chambres, 150 m²) :",[21,16666,16667,16679],{},[24,16668,16669],{},[27,16670,16671,16674,16677],{},[30,16672,16673],{},"Type",[30,16675,16676],{},"Nombre",[30,16678,13232],{},[43,16680,16681,16692,16703,16713,16723,16732,16740,16748,16757,16766,16776,16785,16795],{},[27,16682,16683,16686,16689],{},[48,16684,16685],{},"Éclairage",[48,16687,16688],{},"3–4 circuits",[48,16690,16691],{},"B10A ou B16A",[27,16693,16694,16697,16700],{},[48,16695,16696],{},"Prises générales",[48,16698,16699],{},"4–6 circuits",[48,16701,16702],{},"B16A",[27,16704,16705,16708,16710],{},[48,16706,16707],{},"Cuisine dédiée (four)",[48,16709,4482],{},[48,16711,16712],{},"B20A ou B32A",[27,16714,16715,16718,16720],{},[48,16716,16717],{},"Cuisine dédiée (taque)",[48,16719,4482],{},[48,16721,16722],{},"B32A (triphasé évent.)",[27,16724,16725,16728,16730],{},[48,16726,16727],{},"Cuisine dédiée (lave-vaisselle)",[48,16729,4482],{},[48,16731,16702],{},[27,16733,16734,16736,16738],{},[48,16735,10167],{},[48,16737,4482],{},[48,16739,16702],{},[27,16741,16742,16744,16746],{},[48,16743,10173],{},[48,16745,4482],{},[48,16747,16702],{},[27,16749,16750,16753,16755],{},[48,16751,16752],{},"Prises salle de bain",[48,16754,4482],{},[48,16756,16702],{},[27,16758,16759,16762,16764],{},[48,16760,16761],{},"Prises extérieures",[48,16763,4482],{},[48,16765,16702],{},[27,16767,16768,16771,16773],{},[48,16769,16770],{},"Chauffe-eau \u002F boiler",[48,16772,4482],{},[48,16774,16775],{},"B16A ou B20A",[27,16777,16778,16781,16783],{},[48,16779,16780],{},"Garage",[48,16782,4482],{},[48,16784,16702],{},[27,16786,16787,16790,16792],{},[48,16788,16789],{},"Borne de recharge (si présente)",[48,16791,4482],{},[48,16793,16794],{},"B32A",[27,16796,16797,16802,16807],{},[48,16798,16799],{},[221,16800,16801],{},"Total",[48,16803,16804],{},[221,16805,16806],{},"17–20 circuits",[48,16808],{},[9883,16810,16811],{},[17,16812,16813,16815,16816,16819],{},[221,16814,14912],{}," Maximum ",[221,16817,16818],{},"8 prises simples ou multiples"," par circuit terminal (RGIE Art. 5.3.5.2b). Les circuits d'éclairage peuvent avoir plus de points, mais en pratique on recommande max. 8 luminaires par circuit.",[7849,16821],{},[12,16823,16825],{"id":16824},"étape-2-choisir-les-dispositifs-de-protection","Étape 2 : Choisir les dispositifs de protection",[17,16827,16828,16829,16832],{},"Les dispositifs de protection sont disposés de manière ",[221,16830,16831],{},"hiérarchique"," — de l'alimentation (en haut) vers le bas :",[5686,16834,16836],{"id":16835},"hiérarchie-des-protections","Hiérarchie des protections",[5508,16838,16841],{"className":16839,"code":16840,"language":5513},[5511],"Interrupteur principal (40A ou 63A)\n   └── Différentiel principal 300 mA (Type A-S, sélectif)\n        ├── Différentiel groupe 30 mA #1 (Type A)\n        │    ├── Disj. Éclairage RDC (B10A)\n        │    ├── Disj. Éclairage étage (B10A)\n        │    ├── Disj. Prises séjour (B16A)\n        │    └── Disj. Prises couloir (B16A)\n        ├── Différentiel groupe 30 mA #2 (Type A)\n        │    ├── Disj. Prises cuisine (B16A)\n        │    ├── Disj. Four (B20A)\n        │    ├── Disj. Lave-vaisselle (B16A)\n        │    └── Disj. Prises chambres (B16A)\n        └── Différentiel groupe 30 mA #3 (Type A)\n             ├── Disj. Lave-linge (B16A)\n             ├── Disj. Salle de bain (B16A)\n             ├── Disj. Extérieur (B16A)\n             └── Disj. Garage (B16A)\n",[4068,16842,16840],{"__ignoreMap":1212},[5686,16844,16846],{"id":16845},"types-de-différentiels","Types de différentiels",[21,16848,16849,16860],{},[24,16850,16851],{},[27,16852,16853,16855,16857],{},[30,16854,16673],{},[30,16856,13257],{},[30,16858,16859],{},"Limite de conception",[43,16861,16862,16875,16888,16900],{},[27,16863,16864,16869,16872],{},[48,16865,16866],{},[221,16867,16868],{},"maximum 300 mA, min. type A",[48,16870,16871],{},"Protection à l'origine de l'installation domestique",[48,16873,16874],{},"Calibre et pôles doivent convenir ; le type S n'est qu'une option lorsque la sélectivité temporelle est démontrée",[27,16876,16877,16882,16885],{},[48,16878,16879],{},[221,16880,16881],{},"maximum 30 mA, type A",[48,16883,16884],{},"Haute ou très haute sensibilité",[48,16886,16887],{},"Pour les circuits cités à l'art. 4.2.4.3b ; les conditions propres aux appareils restent à vérifier",[27,16889,16890,16894,16897],{},[48,16891,16892],{},[221,16893,14890],{},[48,16895,16896],{},"Détecte aussi les défauts continus lisses",[48,16898,16899],{},"Seulement si spectre de défaut et concept du matériel l'exigent ; pas de choix général pour toute borne ou tout onduleur",[27,16901,16902,16907,16910],{},[48,16903,16904],{},[221,16905,16906],{},"Type F",[48,16908,16909],{},"Détecte certains courants de défaut à fréquences mixtes",[48,16911,16912],{},"À employer uniquement lorsque charge, norme produit et documentation fabricant demandent cette caractéristique",[5686,16914,16915],{"id":3819},"Sélectivité",[17,16917,16918],{},"La sélectivité ne signifie pas que le différentiel amont « observe » la réaction du différentiel de groupe. Elle se démontre à partir des sensibilités, courbes temps-courant, coordinations fabricant et du concept complet de protection. Un appareil temporisé peut participer à cette solution, mais ne garantit pas à lui seul la sélectivité ni le déclenchement du seul groupe concerné.",[7849,16920],{},[12,16922,16924],{"id":16923},"étape-3-répartition-en-rangées","Étape 3 : Répartition en rangées",[5686,16926,16928],{"id":16927},"règle-rgie-max-8-circuits-terminaux-par-différentiel","Règle RGIE : Max. 8 circuits terminaux par différentiel",[17,16930,16931,16932,16935],{},"Selon le RGIE Art. 4.2.4.3b, un maximum de ",[221,16933,16934],{},"8 circuits terminaux"," peut être raccordé derrière un différentiel (RCD). En pratique, 4–6 circuits par différentiel sont recommandés pour une réserve confortable.",[5686,16937,16939],{"id":16938},"répartition-typique-des-rangées","Répartition typique des rangées",[21,16941,16942,16952],{},[24,16943,16944],{},[27,16945,16946,16949],{},[30,16947,16948],{},"Rangée",[30,16950,16951],{},"Contenu",[43,16953,16954,16964,16974,16984],{},[27,16955,16956,16961],{},[48,16957,16958],{},[221,16959,16960],{},"Rangée 1",[48,16962,16963],{},"Interrupteur principal, Différentiel principal (300 mA), Parafoudre, évent. transfo sonnerie",[27,16965,16966,16971],{},[48,16967,16968],{},[221,16969,16970],{},"Rangée 2",[48,16972,16973],{},"Différentiel groupe #1 (30 mA) + disjoncteurs associés (éclairage + prises séjour)",[27,16975,16976,16981],{},[48,16977,16978],{},[221,16979,16980],{},"Rangée 3",[48,16982,16983],{},"Différentiel groupe #2 (30 mA) + disjoncteurs associés (cuisine + chambres)",[27,16985,16986,16991],{},[48,16987,16988],{},[221,16989,16990],{},"Rangée 4",[48,16992,16993],{},"Différentiel groupe #3 (30 mA) + disjoncteurs associés (SDB, extérieur, garage, technique)",[7849,16995],{},[12,16997,16999],{"id":16998},"étape-4-prévoir-des-emplacements-de-réserve","Étape 4 : Prévoir des emplacements de réserve",[17,17001,17002,17003,17006],{},"Prévoyez au minimum ",[221,17004,17005],{},"20 % d'emplacements de réserve"," — idéalement 30 %. Cela signifie :",[711,17008,17009,17012],{},[714,17010,17011],{},"Pour 20 disjoncteurs nécessaires → au minimum 4–6 emplacements libres.",[714,17013,17014,17015,212],{},"Les emplacements vides sont fermés par des ",[221,17016,17017],{},"obturateurs",[17,17019,17020],{},[221,17021,14863],{},[711,17023,17024,17027,17030],{},[714,17025,17026],{},"Extensions futures (borne de recharge, climatisation, sauna).",[714,17028,17029],{},"Redistribution si un différentiel a trop de circuits.",[714,17031,17032],{},"Éviter un remplacement coûteux du tableau.",[7849,17034],{},[12,17036,17038],{"id":17037},"exemple-tableau-4-rangées-pour-maison-unifamiliale","Exemple : Tableau 4 rangées pour maison unifamiliale",[17,17040,17041],{},"Voici un exemple complet pour une maison belge typique (3 CH, 150 m², sans PV) :",[5686,17043,17045],{"id":17044},"rangée-1-alimentation-protection-18-modules","Rangée 1 — Alimentation & protection (18 modules)",[21,17047,17048,17062],{},[24,17049,17050],{},[27,17051,17052,17055,17057,17060],{},[30,17053,17054],{},"Position",[30,17056,16492],{},[30,17058,17059],{},"Modules",[30,17061,14730],{},[43,17063,17064,17077,17090,17102,17115],{},[27,17065,17066,17069,17072,17074],{},[48,17067,17068],{},"1–2",[48,17070,17071],{},"Interrupteur principal 2P",[48,17073,4515],{},[48,17075,17076],{},"40A interrupteur principal",[27,17078,17079,17082,17085,17087],{},[48,17080,17081],{},"3–4",[48,17083,17084],{},"Différentiel principal 2P",[48,17086,4515],{},[48,17088,17089],{},"300 mA Type A-S",[27,17091,17092,17095,17097,17099],{},[48,17093,17094],{},"5–8",[48,17096,16555],{},[48,17098,16643],{},[48,17100,17101],{},"Protection contre les surtensions",[27,17103,17104,17107,17110,17112],{},[48,17105,17106],{},"9–10",[48,17108,17109],{},"Transfo sonnerie",[48,17111,4515],{},[48,17113,17114],{},"Sonnerie 8V",[27,17116,17117,17120,17123,17126],{},[48,17118,17119],{},"11–18",[48,17121,17122],{},"Réserve",[48,17124,17125],{},"8",[48,17127,17128],{},"Obturateurs",[5686,17130,17132],{"id":17131},"rangée-2-groupe-1-éclairage-séjour-18-modules","Rangée 2 — Groupe 1 : Éclairage + séjour (18 modules)",[21,17134,17135,17147],{},[24,17136,17137],{},[27,17138,17139,17141,17143,17145],{},[30,17140,17054],{},[30,17142,16492],{},[30,17144,17059],{},[30,17146,14730],{},[43,17148,17149,17160,17172,17183,17195,17208,17220,17231],{},[27,17150,17151,17153,17156,17158],{},[48,17152,17068],{},[48,17154,17155],{},"Différentiel groupe 30 mA",[48,17157,4515],{},[48,17159,14876],{},[27,17161,17162,17164,17167,17169],{},[48,17163,4532],{},[48,17165,17166],{},"Disj. B10A",[48,17168,4482],{},[48,17170,17171],{},"Éclairage RDC",[27,17173,17174,17176,17178,17180],{},[48,17175,16643],{},[48,17177,17166],{},[48,17179,4482],{},[48,17181,17182],{},"Éclairage étage",[27,17184,17185,17188,17190,17192],{},[48,17186,17187],{},"5",[48,17189,17166],{},[48,17191,4482],{},[48,17193,17194],{},"Éclairage cave\u002Fextérieur",[27,17196,17197,17200,17203,17205],{},[48,17198,17199],{},"6",[48,17201,17202],{},"Disj. B16A",[48,17204,4482],{},[48,17206,17207],{},"Prises séjour",[27,17209,17210,17213,17215,17217],{},[48,17211,17212],{},"7",[48,17214,17202],{},[48,17216,4482],{},[48,17218,17219],{},"Prises salle à manger",[27,17221,17222,17224,17226,17228],{},[48,17223,17125],{},[48,17225,17202],{},[48,17227,4482],{},[48,17229,17230],{},"Prises couloir",[27,17232,17233,17236,17238,17241],{},[48,17234,17235],{},"9–18",[48,17237,17122],{},[48,17239,17240],{},"10",[48,17242,17128],{},[5686,17244,17246],{"id":17245},"rangée-3-groupe-2-cuisine-chambres-18-modules","Rangée 3 — Groupe 2 : Cuisine + chambres (18 modules)",[21,17248,17249,17261],{},[24,17250,17251],{},[27,17252,17253,17255,17257,17259],{},[30,17254,17054],{},[30,17256,16492],{},[30,17258,17059],{},[30,17260,14730],{},[43,17262,17263,17273,17284,17296,17307,17318,17329,17340],{},[27,17264,17265,17267,17269,17271],{},[48,17266,17068],{},[48,17268,17155],{},[48,17270,4515],{},[48,17272,14876],{},[27,17274,17275,17277,17279,17281],{},[48,17276,4532],{},[48,17278,17202],{},[48,17280,4482],{},[48,17282,17283],{},"Prises cuisine",[27,17285,17286,17288,17291,17293],{},[48,17287,16643],{},[48,17289,17290],{},"Disj. B20A",[48,17292,4482],{},[48,17294,17295],{},"Four (dédié)",[27,17297,17298,17300,17302,17304],{},[48,17299,17187],{},[48,17301,17202],{},[48,17303,4482],{},[48,17305,17306],{},"Lave-vaisselle (dédié)",[27,17308,17309,17311,17313,17315],{},[48,17310,17199],{},[48,17312,17202],{},[48,17314,4482],{},[48,17316,17317],{},"Réfrigérateur (dédié)",[27,17319,17320,17322,17324,17326],{},[48,17321,17212],{},[48,17323,17202],{},[48,17325,4482],{},[48,17327,17328],{},"Prises chambre 1",[27,17330,17331,17333,17335,17337],{},[48,17332,17125],{},[48,17334,17202],{},[48,17336,4482],{},[48,17338,17339],{},"Prises chambres 2+3",[27,17341,17342,17344,17346,17348],{},[48,17343,17235],{},[48,17345,17122],{},[48,17347,17240],{},[48,17349,17128],{},[5686,17351,17353],{"id":17352},"rangée-4-groupe-3-sdb-extérieur-technique-18-modules","Rangée 4 — Groupe 3 : SDB, extérieur, technique (18 modules)",[21,17355,17356,17368],{},[24,17357,17358],{},[27,17359,17360,17362,17364,17366],{},[30,17361,17054],{},[30,17363,16492],{},[30,17365,17059],{},[30,17367,14730],{},[43,17369,17370,17380,17390,17401,17412,17423,17433,17443],{},[27,17371,17372,17374,17376,17378],{},[48,17373,17068],{},[48,17375,17155],{},[48,17377,4515],{},[48,17379,14876],{},[27,17381,17382,17384,17386,17388],{},[48,17383,4532],{},[48,17385,17202],{},[48,17387,4482],{},[48,17389,16752],{},[27,17391,17392,17394,17396,17398],{},[48,17393,16643],{},[48,17395,17202],{},[48,17397,4482],{},[48,17399,17400],{},"Lave-linge (dédié)",[27,17402,17403,17405,17407,17409],{},[48,17404,17187],{},[48,17406,17202],{},[48,17408,4482],{},[48,17410,17411],{},"Sèche-linge (dédié)",[27,17413,17414,17416,17418,17420],{},[48,17415,17199],{},[48,17417,17290],{},[48,17419,4482],{},[48,17421,17422],{},"Boiler (dédié)",[27,17424,17425,17427,17429,17431],{},[48,17426,17212],{},[48,17428,17202],{},[48,17430,4482],{},[48,17432,16761],{},[27,17434,17435,17437,17439,17441],{},[48,17436,17125],{},[48,17438,17202],{},[48,17440,4482],{},[48,17442,16780],{},[27,17444,17445,17447,17449,17451],{},[48,17446,17235],{},[48,17448,17122],{},[48,17450,17240],{},[48,17452,17128],{},[17,17454,17455],{},[221,17456,17457],{},"Total : 18 disjoncteurs + 4 différentiels + parafoudre + interrupteur principal + transfo sonnerie = 34 modules occupés sur 72 → 53 % de réserve",[7849,17459],{},[12,17461,17463],{"id":17462},"erreurs-typiques-de-planification","Erreurs typiques de planification",[21,17465,17466,17479],{},[24,17467,17468],{},[27,17469,17470,17473,17476],{},[30,17471,17472],{},"Erreur",[30,17474,17475],{},"Conséquence",[30,17477,17478],{},"Solution",[43,17480,17481,17492,17503,17514,17525,17536,17547],{},[27,17482,17483,17486,17489],{},[48,17484,17485],{},"Trop peu de rangées",[48,17487,17488],{},"Pas de marge utile ou thermique",[48,17490,17491],{},"Dimensionner selon modules, câblage et données du coffret",[27,17493,17494,17497,17500],{},[48,17495,17496],{},"Parafoudre écarté sans étude",[48,17498,17499],{},"Le concept de protection reste sans justification",[48,17501,17502],{},"Vérifier l'applicabilité et le choix pour le projet",[27,17504,17505,17508,17511],{},[48,17506,17507],{},"Plus de 8 circuits terminaux par différentiel",[48,17509,17510],{},"Non-conformité RGIE (Art. 4.2.4.3b)",[48,17512,17513],{},"Ajouter un différentiel de groupe",[27,17515,17516,17519,17522],{},[48,17517,17518],{},"Étiquetage manquant",[48,17520,17521],{},"Remarque lors du contrôle",[48,17523,17524],{},"Étiqueter chaque disjoncteur (n° circuit + fonction)",[27,17526,17527,17530,17533],{},[48,17528,17529],{},"Protection différentielle générale absente",[48,17531,17532],{},"Chaîne au point d'alimentation incomplète",[48,17534,17535],{},"Vérifier professionnellement la configuration applicable jusqu'à 300 mA",[27,17537,17538,17541,17544],{},[48,17539,17540],{},"Type de différentiel de borne choisi par raccourci",[48,17542,17543],{},"La protection contre le courant continu peut être insuffisante",[48,17545,17546],{},"Croiser chapitre 7.22, détection DC intégrée et notice fabricant",[27,17548,17549,17552,17555],{},[48,17550,17551],{},"Pas de réserve utilisable",[48,17553,17554],{},"Extension inutilement difficile",[48,17556,17557],{},"Prévoir une marge de modules, bornes et câblage propre au projet",[7849,17559],{},[12,17561,17563],{"id":17562},"étiquetage-et-documentation","Étiquetage et documentation",[17,17565,17566,17567,17570],{},"Chaque disjoncteur doit être ",[221,17568,17569],{},"étiqueté"," avec :",[711,17572,17573,17576,17579],{},[714,17574,17575],{},"Numéro de circuit (identique au schéma unifilaire et au plan de situation)",[714,17577,17578],{},"Fonction (par ex. « Éclairage RDC », « Prises cuisine »)",[714,17580,17581],{},"Optionnel : pièce ou étage",[17,17583,17584,17585,17588],{},"Collez l'étiquette ",[221,17586,17587],{},"dans le couvercle"," du tableau ou utilisez une bandelette d'identification. La plupart des fabricants de tableaux fournissent des inserts inscriptibles.",[12,17590,17592],{"id":17591},"passer-de-limplantation-au-projet-dexécution","Passer de l'implantation au projet d'exécution",[17,17594,17595],{},"Le comptage des modules ne constitue que l'étude d'encombrement. Avant toute commande, l'électricien vérifie les données du raccordement, le schéma de mise à la terre, le courant de court-circuit présumé, la sélectivité ou la protection de secours ainsi que les associations admises par les fabricants. Le calibre, le pouvoir de coupure et la section ne se recopient donc pas d'un exemple de maison. La dissipation thermique dans le coffret, la température ambiante, l'aération et les limites des bornes influencent également le choix final.",[17,17597,17598],{},"Relisez chaque rangée comme une chaîne. L'alimentation, la coupure générale, les différentiels et le parafoudre doivent former un chemin compréhensible avant les circuits terminaux. Une rangée bien alignée ne garantit ni sélectivité ni coordination. En présence de photovoltaïque, de stockage, d'un groupe ou d'une borne, le document doit aussi montrer les sens d'énergie possibles et les parties susceptibles de rester alimentées. Les instructions du différentiel, du SPD, de l'onduleur ou de la borne concernée restent des données obligatoires de l'étude professionnelle.",[17,17600,17601],{},"La réserve ne se limite pas à des modules vides. Pensez aux bornes disponibles, aux goulottes réellement utilisables, aux barres N et PE accessibles, à l'espace de mesure et au sens d'une extension future. Aucun pourcentage universel de réserve n'est imposé par le RGIE. La marge dépend des usages prévus, des limites du coffret et de la puissance disponible au raccordement.",[17,17603,17604],{},"Avant l'export, comparez trois réalités : l'occupation physique du tableau, la chaîne de protection du schéma unifilaire et les références du plan de situation. Elles doivent décrire le même état réalisé. Le Livre 1 V06 demande un numéro, une version et la date de cette version sur les schémas et documents. Les plans domestiques reprennent aussi l'adresse de l'installation et les données du responsable des travaux. L'auto-contrôle PlanElec peut signaler des lacunes modélisées ; il ne produit ni mesures, ni preuve fabricant, ni décision d'un organisme agréé.",[12,17606,17608],{"id":17607},"base-officielle","Base officielle",[711,17610,17611,17617],{},[714,17612,17613],{},[203,17614,17616],{"href":5371,"rel":17615},[5373],"SPF Économie : publication officielle du RGIE, Livre 1 Version 06",[714,17618,17619],{},"Voir notamment la section 3.1.2 et les parties 4 et 5 consacrées aux protections et au matériel.",[7849,17621],{},[12,17623,10024],{"id":10023},[711,17625,17626,17630,17636,17640],{},[714,17627,17628],{},[203,17629,15489],{"href":3283},[714,17631,17632],{},[203,17633,17635],{"href":17634},"\u002Ffr\u002Fblog\u002F30ma-rcd-par-prise","Différentiel 30 mA obligatoire par circuit prises",[714,17637,17638],{},[203,17639,11726],{"href":1579},[714,17641,17642],{},[203,17643,17644],{"href":6354},"Installation PV dans le schéma",[7849,17646],{},[17,17648,17649],{},[60,17650,17651,17652,17655,17656],{},"Planifiez votre tableau visuellement avec le ",[221,17653,17654],{},"PlanElec Cabinet Editor"," et placez les modules sur le rail DIN. L'auto-contrôle indicatif ne remplace ni l'étude professionnelle ni le contrôle officiel. ",[203,17657,17658],{"href":7861},"Essayer maintenant →",{"title":1212,"searchDepth":1213,"depth":1213,"links":17660},[17661,17666,17667,17672,17676,17677,17683,17684,17685,17686,17687],{"id":16452,"depth":1213,"text":16453,"children":17662},[17663,17664,17665],{"id":16456,"depth":5848,"text":16457},{"id":16471,"depth":5848,"text":16472},{"id":16575,"depth":5848,"text":16576},{"id":16660,"depth":1213,"text":16661},{"id":16824,"depth":1213,"text":16825,"children":17668},[17669,17670,17671],{"id":16835,"depth":5848,"text":16836},{"id":16845,"depth":5848,"text":16846},{"id":3819,"depth":5848,"text":16915},{"id":16923,"depth":1213,"text":16924,"children":17673},[17674,17675],{"id":16927,"depth":5848,"text":16928},{"id":16938,"depth":5848,"text":16939},{"id":16998,"depth":1213,"text":16999},{"id":17037,"depth":1213,"text":17038,"children":17678},[17679,17680,17681,17682],{"id":17044,"depth":5848,"text":17045},{"id":17131,"depth":5848,"text":17132},{"id":17245,"depth":5848,"text":17246},{"id":17352,"depth":5848,"text":17353},{"id":17462,"depth":1213,"text":17463},{"id":17562,"depth":1213,"text":17563},{"id":17591,"depth":1213,"text":17592},{"id":17607,"depth":1213,"text":17608},{"id":10023,"depth":1213,"text":10024},"2026-04-07","Guide complet pour la planification d'un tableau de distribution. Rail DIN, dispositifs de protection, répartition en rangées et exemple pour une maison unifamiliale.",{},"\u002Fblog\u002Fdistribution-board-planning.fr",{"title":16441,"description":17689},"planifier-tableau-electrique","blog\u002Fdistribution-board-planning.fr",[1247,17696,17697,17698,12640,1242,17699,17700],"distribution","rail DIN","RCD","planification","maison unifamiliale","JzGfPeTQU4oLnA_6Yj7xKFJT0ak4CAne9EP5mPfkVbM",{"id":17703,"title":17704,"articleId":17705,"body":17706,"category":1228,"date":18539,"description":18540,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":18541,"navigation":1234,"path":18542,"publishDate":18539,"readTime":1994,"refreshInterval":1237,"seo":18543,"slug":18544,"stem":18545,"tags":18546,"__hash__":18551},"blog\u002Fblog\u002Fdraw-situation-plan.fr.md","Dessiner un plan de situation : Guide étape par étape selon le RGIE","draw-situation-plan",{"type":9,"value":17707,"toc":18517},[17708,17715,17731,17734,17736,17740,17744,17747,17751,17773,17777,17780,17883,17885,17889,17894,18062,18069,18071,18075,18078,18082,18115,18119,18139,18143,18160,18164,18167,18171,18190,18192,18196,18203,18208,18219,18224,18238,18255,18257,18261,18264,18290,18292,18294,18382,18384,18388,18451,18455,18458,18461,18464,18468,18471,18474,18476,18487,18489,18491,18505,18507],[17,17709,17710,17711,17714],{},"Le plan de situation (aussi appelé schéma de position) montre ",[221,17712,17713],{},"où exactement"," chaque composant électrique se trouve dans votre bâtiment. Pour une nouvelle installation domestique ou une modification ou extension importante, il est établi avec le schéma unifilaire. Les installations existantes et petits changements suivent des règles précises ; l'organisme agréé examine le dossier concret.",[9883,17716,17717],{},[17,17718,17719,17722,17723,17726,17727,17730],{},[221,17720,17721],{},"En bref :"," Tandis que le schéma unifilaire représente le ",[60,17724,17725],{},"raccordement logique"," (quel interrupteur commande quel luminaire, via quel circuit), le plan de situation montre la ",[60,17728,17729],{},"position physique"," de chaque composant sur le plan d'étage.",[17,17732,17733],{},"Ce guide explique comment préparer un plan de situation vérifiable, étape par étape. Seul un organisme agréé peut conclure à la conformité du dossier complet et de l'installation réalisée.",[7849,17735],{},[12,17737,17739],{"id":17738},"étape-1-préparer-le-plan-détage","Étape 1 : Préparer le plan d'étage",[5686,17741,17743],{"id":17742},"dimensions-et-échelle","Dimensions et échelle",[17,17745,17746],{},"Le plan d'étage constitue la base de votre plan de situation. Vous pouvez le reprendre d'un plan de construction ou le dessiner vous-même.",[17,17748,17749],{},[221,17750,13530],{},[711,17752,17753,17760,17766],{},[714,17754,17755,17756,17759],{},"Utilisez une ",[221,17757,17758],{},"échelle uniforme"," (courante : 1:50 ou 1:100).",[714,17761,17762,17763,212],{},"Dessinez tous les ",[221,17764,17765],{},"murs, portes et fenêtres",[714,17767,17768,17769,17772],{},"Marquez le ",[221,17770,17771],{},"sens d'ouverture"," des portes (quart de cercle) — cela influence la position des interrupteurs.",[5686,17774,17776],{"id":17775},"étiqueter-les-pièces","Étiqueter les pièces",[17,17778,17779],{},"Identifiez chaque pièce avec sa désignation et idéalement sa surface :",[21,17781,17782,17795],{},[24,17783,17784],{},[27,17785,17786,17789,17792],{},[30,17787,17788],{},"Abréviation",[30,17790,17791],{},"Pièce",[30,17793,17794],{},"Surface typique",[43,17796,17797,17808,17819,17830,17841,17852,17862,17873],{},[27,17798,17799,17802,17805],{},[48,17800,17801],{},"SÉJ",[48,17803,17804],{},"Séjour",[48,17806,17807],{},"25–40 m²",[27,17809,17810,17813,17816],{},[48,17811,17812],{},"CUI",[48,17814,17815],{},"Cuisine",[48,17817,17818],{},"10–20 m²",[27,17820,17821,17824,17827],{},[48,17822,17823],{},"CH",[48,17825,17826],{},"Chambre",[48,17828,17829],{},"12–18 m²",[27,17831,17832,17835,17838],{},[48,17833,17834],{},"SDB",[48,17836,17837],{},"Salle de bain",[48,17839,17840],{},"5–10 m²",[27,17842,17843,17846,17849],{},[48,17844,17845],{},"COU",[48,17847,17848],{},"Couloir",[48,17850,17851],{},"5–15 m²",[27,17853,17854,17857,17859],{},[48,17855,17856],{},"GAR",[48,17858,16780],{},[48,17860,17861],{},"15–30 m²",[27,17863,17864,17867,17870],{},[48,17865,17866],{},"CAV",[48,17868,17869],{},"Cave",[48,17871,17872],{},"variable",[27,17874,17875,17878,17881],{},[48,17876,17877],{},"EXT",[48,17879,17880],{},"Extérieur",[48,17882,17872],{},[7849,17884],{},[12,17886,17888],{"id":17887},"étape-2-utiliser-les-symboles-rgie","Étape 2 : Utiliser les symboles RGIE",[17,17890,1530,17891,17893],{},[221,17892,5442],{}," du RGIE donne une liste non exhaustive de symboles. Si aucun symbole n'est repris pour un composant, un autre signe clairement identifiable peut être utilisé s'il est défini dans la légende. Voici dix groupes utiles pour le plan de situation :",[21,17895,17896,17911],{},[24,17897,17898],{},[27,17899,17900,17903,17906,17908],{},[30,17901,17902],{},"N°",[30,17904,17905],{},"Symbole",[30,17907,11157],{},[30,17909,17910],{},"Utilisation",[43,17912,17913,17928,17942,17957,17972,17987,18002,18017,18031,18047],{},[27,17914,17915,17917,17920,17925],{},[48,17916,4482],{},[48,17918,17919],{},"⏚ Demi-cercle",[48,17921,17922],{},[221,17923,17924],{},"Prise simple",[48,17926,17927],{},"Marquer position murale",[27,17929,17930,17932,17935,17940],{},[48,17931,4515],{},[48,17933,17934],{},"⏚⏚ Double demi-cercle",[48,17936,17937],{},[221,17938,17939],{},"Prise double",[48,17941,17927],{},[27,17943,17944,17946,17949,17954],{},[48,17945,4532],{},[48,17947,17948],{},"○ avec croix",[48,17950,17951],{},[221,17952,17953],{},"Plafonnier",[48,17955,17956],{},"Centre de la pièce\u002Fposition",[27,17958,17959,17961,17964,17969],{},[48,17960,16643],{},[48,17962,17963],{},"─○ avec trait",[48,17965,17966],{},[221,17967,17968],{},"Applique murale",[48,17970,17971],{},"Sur le mur",[27,17973,17974,17976,17979,17984],{},[48,17975,17187],{},[48,17977,17978],{},"Symbole interrupteur",[48,17980,17981],{},[221,17982,17983],{},"Interrupteur unipolaire",[48,17985,17986],{},"À côté de la porte (côté ouverture)",[27,17988,17989,17991,17994,17999],{},[48,17990,17199],{},[48,17992,17993],{},"Symbole interrupteur 2 flèches",[48,17995,17996],{},[221,17997,17998],{},"Interrupteur sériel",[48,18000,18001],{},"Commande 2 luminaires",[27,18003,18004,18006,18009,18014],{},[48,18005,17212],{},[48,18007,18008],{},"Symbole interrupteur avec ligne",[48,18010,18011],{},[221,18012,18013],{},"Interrupteur va-et-vient",[48,18015,18016],{},"Deux points, un luminaire",[27,18018,18019,18021,18024,18028],{},[48,18020,17125],{},[48,18022,18023],{},"Rectangle avec éclair",[48,18025,18026],{},[221,18027,12397],{},[48,18029,18030],{},"Généralement couloir\u002Flocal technique",[27,18032,18033,18036,18039,18044],{},[48,18034,18035],{},"9",[48,18037,18038],{},"⏚ avec PE",[48,18040,18041],{},[221,18042,18043],{},"Prise de terre",[48,18045,18046],{},"Point de mise à la terre",[27,18048,18049,18051,18054,18059],{},[48,18050,17240],{},[48,18052,18053],{},"Cercle avec R",[48,18055,18056],{},[221,18057,18058],{},"Détecteur de fumée",[48,18060,18061],{},"Chaque chambre, couloir, cage d'escalier",[9883,18063,18064],{},[17,18065,18066,18068],{},[221,18067,14912],{}," Utilisez les symboles RGIE du Tableau 2.23 pour les composants courants. Si des symboles différents sont nécessaires, ils doivent être clairement identifiables et expliqués dans la légende — les symboles non définis ou non expliqués seront refusés lors du contrôle.",[7849,18070],{},[12,18072,18074],{"id":18073},"étape-3-dessiner-les-composants","Étape 3 : Dessiner les composants",[17,18076,18077],{},"Placez maintenant les symboles sur le plan d'étage. Les règles suivantes aident au positionnement correct :",[5686,18079,18081],{"id":18080},"prises-de-courant","Prises de courant",[711,18083,18084,18091,18097,18103,18109],{},[714,18085,18086,18087,18090],{},"Dessiner ",[221,18088,18089],{},"sur le mur",", à la position réelle.",[714,18092,18093,18096],{},[221,18094,18095],{},"Cuisine :"," Relever séparément les prises de travail et appareils fixes réels ; quantité et circuits dédiés découlent de l'usage et de l'étude professionnelle.",[714,18098,18099,18102],{},[221,18100,18101],{},"Pièces de vie :"," Dessiner les prises prévues ou existantes ; le RGIE ne fixe aucun nombre général par surface.",[714,18104,18105,18108],{},[221,18106,18107],{},"Salle de bain :"," Prises basse tension à partir de la zone 2 (uniquement pour les baignoires ; la prise doit être protégée par un dispositif différentiel à très haute sensibilité ≤ 10 mA, ou individuellement par un transformateur de séparation d'une puissance maximale de 100 W) ou hors zones. Pour les douches, la zone 2 n'existe pas (art. 7.1.3.2 n° 3b, art. 7.1.5.2d).",[714,18110,18111,18114],{},[221,18112,18113],{},"Extérieur :"," Déterminer professionnellement les influences externes, l'indice IP requis et la protection 30 mA applicable ; un différentiel dédié n'est pas une conclusion générale du plan.",[5686,18116,18118],{"id":18117},"interrupteurs","Interrupteurs",[711,18120,18121,18127,18133],{},[714,18122,18123,18126],{},[221,18124,18125],{},"À côté de la porte"," du côté de l'ouverture, à environ 105 cm de hauteur (recommandation pratique — le RGIE ne prescrit pas de hauteur spécifique pour les interrupteurs, mais exige qu'ils soient « facilement accessibles »).",[714,18128,18129,18132],{},[221,18130,18131],{},"Interrupteurs va-et-vient"," pour les pièces à plusieurs entrées ou en début\u002Ffin d'escalier.",[714,18134,18135,18136,212],{},"Reliez les interrupteurs et les luminaires associés par une ",[221,18137,18138],{},"ligne pointillée",[5686,18140,18142],{"id":18141},"points-lumineux","Points lumineux",[711,18144,18145,18151,18157],{},[714,18146,18147,18150],{},[221,18148,18149],{},"Plafonniers"," au centre de la pièce ou à la position prévue.",[714,18152,18153,18156],{},[221,18154,18155],{},"Appliques murales"," à la position sur le mur.",[714,18158,18159],{},"Dessiner tous les points lumineux réellement prévus ou présents ; leur nombre relève de l'usage et de l'étude.",[5686,18161,18163],{"id":18162},"informations-régionales-de-sécurité-incendie","Informations régionales de sécurité incendie",[17,18165,18166],{},"Les détecteurs peuvent être ajoutés dans une couche bâtiment distincte. Les exigences varient selon la région et l'usage et se vérifient auprès de la source officielle compétente actuelle. Elles ne constituent pas une mention générale du plan RGIE et restent séparées des références électriques.",[5686,18168,18170],{"id":18169},"consommateurs-spéciaux","Consommateurs spéciaux",[711,18172,18173,18178,18184],{},[714,18174,18175,18177],{},[221,18176,6620],{}," (véhicule électrique) : garage ou mur extérieur, circuit dédié.",[714,18179,18180,18183],{},[221,18181,18182],{},"Chauffe-eau\u002FBoiler :"," Circuit dédié, dessiner la position.",[714,18185,18186,18189],{},[221,18187,18188],{},"Pompe à chaleur\u002FClimatisation :"," Marquer unité extérieure + unité intérieure.",[7849,18191],{},[12,18193,18195],{"id":18194},"étape-4-attribuer-les-numéros-de-circuits","Étape 4 : Attribuer les numéros de circuits",[17,18197,18198,18199,18202],{},"Chaque composant du plan de situation reçoit le ",[221,18200,18201],{},"même numéro de circuit"," que dans le schéma unifilaire. C'est essentiel pour l'attribution lors du contrôle.",[17,18204,18205],{},[221,18206,18207],{},"Comment ça marche :",[5034,18209,18210,18213,18216],{},[714,18211,18212],{},"Le RGIE identifie les circuits élémentaires par une lettre majuscule (A, B, C, ...) et les éléments individuels (point lumineux, prise) par un numéro d'ordre — par ex. « A1, A2, ... ».",[714,18214,18215],{},"Inscrivez cet identifiant à côté de chaque composant sur le plan de situation.",[714,18217,18218],{},"Une numérotation simplifiée (par ex. « C1 » ou « 1 ») est courante en pratique, pour autant que le schéma unifilaire et le plan de situation restent cohérents.",[17,18220,18221],{},[221,18222,18223],{},"Exemple :",[711,18225,18226,18229,18232,18235],{},[714,18227,18228],{},"Circuit 1 : Éclairage rez-de-chaussée → Tous les luminaires du RDC reçoivent « 1 ».",[714,18230,18231],{},"Circuit 2 : Prises séjour → Toutes les prises du séjour reçoivent « 2 ».",[714,18233,18234],{},"Circuit 3 : Prises cuisine → Toutes les prises de cuisine reçoivent « 3 ».",[714,18236,18237],{},"Circuit 4 : Dédié four → Une prise avec « 4 ».",[9883,18239,18240,18249],{},[17,18241,18242,18244,18245,18248],{},[221,18243,13530],{}," Les numéros doivent correspondre ",[221,18246,18247],{},"exactement"," entre le schéma unifilaire et le plan de situation. Les incohérences sont l'une des causes les plus fréquentes de remarques lors du contrôle.",[17,18250,18251,18254],{},[221,18252,18253],{},"Obligation de documentation :"," Art. 9.1.2 n° 1 (schéma unifilaire) et art. 9.1.2 n° 2 (plan de situation).",[7849,18256],{},[12,18258,18260],{"id":18259},"étape-5-légende-et-étiquetage","Étape 5 : Légende et étiquetage",[17,18262,18263],{},"Complétez votre plan avec :",[711,18265,18266,18272,18278,18284],{},[714,18267,18268,18271],{},[221,18269,18270],{},"Légende"," avec tous les symboles utilisés et leur signification.",[714,18273,18274,18277],{},[221,18275,18276],{},"Cartouche"," avec : nom du propriétaire, adresse, date, auteur du plan, échelle.",[714,18279,18280,18283],{},[221,18281,18282],{},"Flèche nord"," (optionnel, mais utile).",[714,18285,18286,18289],{},[221,18287,18288],{},"Indication d'étage"," pour les bâtiments à plusieurs niveaux (un plan par étage).",[7849,18291],{},[12,18293,5266],{"id":5265},[21,18295,18296,18306],{},[24,18297,18298],{},[27,18299,18300,18302,18304],{},[30,18301,17472],{},[30,18303,17475],{},[30,18305,17478],{},[43,18307,18308,18319,18330,18340,18350,18361,18372],{},[27,18309,18310,18313,18316],{},[48,18311,18312],{},"Présenter les règles incendie régionales comme règle RGIE",[48,18314,18315],{},"Mauvaise base de contrôle",[48,18317,18318],{},"Vérifier séparément la source régionale actuelle et identifier la couche",[27,18320,18321,18324,18327],{},[48,18322,18323],{},"Traiter toutes les prises extérieures pareil",[48,18325,18326],{},"Influences ou protection potentiellement erronées",[48,18328,18329],{},"Étudier indice IP et protection 30 mA pour le projet",[27,18331,18332,18335,18337],{},[48,18333,18334],{},"Étiquetage \u002F numéros de circuits manquants",[48,18336,14643],{},[48,18338,18339],{},"Numéroter chaque composant",[27,18341,18342,18345,18347],{},[48,18343,18344],{},"Symboles non définis\u002Fnon expliqués",[48,18346,14643],{},[48,18348,18349],{},"Utiliser les symboles RGIE (Tableau 2.23) ; choisir des symboles différents de façon claire et les expliquer dans la légende",[27,18351,18352,18355,18358],{},[48,18353,18354],{},"Interrupteur du mauvais côté de la porte",[48,18356,18357],{},"Non pratique (pas d'infraction RGIE)",[48,18359,18360],{},"Vérifier le sens d'ouverture",[27,18362,18363,18366,18369],{},[48,18364,18365],{},"Prise de salle de bains représentée dans une zone erronée",[48,18367,18368],{},"Le plan et l'exécution peuvent produire un constat de sécurité",[48,18370,18371],{},"Vérifier professionnellement zones et protections selon le chapitre 7.1 actuel",[27,18373,18374,18377,18379],{},[48,18375,18376],{},"Pas de légende",[48,18378,14643],{},[48,18380,18381],{},"Joindre un tableau de symboles",[7849,18383],{},[12,18385,18387],{"id":18386},"checklist-avant-soumission","Checklist avant soumission",[711,18389,18391,18397,18403,18409,18415,18421,18427,18433,18439,18445],{"className":18390},[6084],[714,18392,18394,18396],{"className":18393},[6088],[6090,18395],{"disabled":1234,"type":6092}," Toutes les pièces étiquetées",[714,18398,18400,18402],{"className":18399},[6088],[6090,18401],{"disabled":1234,"type":6092}," Toutes les prises, interrupteurs, luminaires dessinés",[714,18404,18406,18408],{"className":18405},[6088],[6090,18407],{"disabled":1234,"type":6092}," Informations incendie régionales, si affichées, vérifiées et identifiées séparément",[714,18410,18412,18414],{"className":18411},[6088],[6090,18413],{"disabled":1234,"type":6092}," Prises extérieures relevées avec étude IP et protection propre au projet",[714,18416,18418,18420],{"className":18417},[6088],[6090,18419],{"disabled":1234,"type":6092}," Numéros de circuits sur chaque composant",[714,18422,18424,18426],{"className":18423},[6088],[6090,18425],{"disabled":1234,"type":6092}," Les numéros correspondent au schéma unifilaire",[714,18428,18430,18432],{"className":18429},[6088],[6090,18431],{"disabled":1234,"type":6092}," Symboles RGIE utilisés (Tableau 2.23)",[714,18434,18436,18438],{"className":18435},[6088],[6090,18437],{"disabled":1234,"type":6092}," Légende présente",[714,18440,18442,18444],{"className":18441},[6088],[6090,18443],{"disabled":1234,"type":6092}," Cartouche avec nom, adresse, date",[714,18446,18448,18450],{"className":18447},[6088],[6090,18449],{"disabled":1234,"type":6092}," Un plan par étage",[12,18452,18454],{"id":18453},"faire-la-visite-de-concordance-sur-place","Faire la visite de concordance sur place",[17,18456,18457],{},"Parcourez le bâtiment avec le projet imprimé ou affiché. Partez du tableau et suivez chaque circuit. Ne vérifiez pas seulement la présence d'une prise : distinguez prise multiple, prise commandée, boîte de connexion, raccordement fixe et point lumineux. La référence d'un interrupteur doit permettre d'identifier le luminaire ou l'appareil commandé. Les équipements cachés par un meuble, les points extérieurs, les locaux techniques et les dépendances sont souvent oubliés.",[17,18459,18460],{},"Comparez ensuite le schéma unifilaire. Un élément A3 sur le plan de situation doit correspondre au même A3 du circuit A. Les doublons, numéros sautés et appareils déplacés après le relevé créent des dossiers contradictoires. Pour plusieurs niveaux ou bâtiments, adoptez une structure de feuilles explicite et conservez numéro, version et date de version sur chaque document diffusé.",[17,18462,18463],{},"Le plan décrit l'état réel et non le seul projet initial. Ne clôturez une modification qu'après vérification de la position et du parcours concernés. Pour une modification domestique non importante, le Livre 1 peut accepter une description succincte à la place d'un nouveau schéma unifilaire ; la modification ou l'extension reste à reporter sur le plan de situation. Une modification ou extension importante exige des plans actualisés et le contrôle des travaux concernés avant mise en usage.",[12,18465,18467],{"id":18466},"ce-quun-symbole-ne-démontre-pas","Ce qu'un symbole ne démontre pas",[17,18469,18470],{},"Un symbole n'atteste ni hauteur de pose, ni indice de protection, ni respect des volumes de salle de bains, ni qualité de terre, ni temps de coupure. Il faut une visite, des mesures et parfois les documents du fabricant. Les obligations de détecteurs de fumée relèvent aussi des règles régionales de construction et de logement ; elles ne doivent pas être transformées en exigence générale du plan RGIE.",[17,18472,18473],{},"PlanElec relie position et affectation électrique dans le même projet, mais chaque proposition doit être contrôlée. Un équipement non placé, sans circuit ou présent uniquement sur une image de référence ne peut pas être considéré comme achevé. L'auto-contrôle est indicatif et limité aux règles prises en charge. L'évaluation officielle appartient à l'organisme agréé.",[12,18475,10009],{"id":10008},[711,18477,18478,18484],{},[714,18479,18480],{},[203,18481,18483],{"href":5371,"rel":18482},[5373],"SPF Économie : RGIE, Livre 1 dans sa version officielle actuelle",[714,18485,18486],{},"La section 3.1.2 et le tableau 2.23 constituent la base. Si le tableau ne prévoit aucun symbole, un signe non ambigu défini dans la légende peut être employé.",[7849,18488],{},[12,18490,10024],{"id":10023},[711,18492,18493,18497,18501],{},[714,18494,18495],{},[203,18496,15489],{"href":3283},[714,18498,18499],{},[203,18500,7847],{"href":6216},[714,18502,18503],{},[203,18504,15494],{"href":567},[7849,18506],{},[17,18508,18509],{},[60,18510,6951,18511,18513,18514],{},[221,18512,5823],{},", créez votre plan de situation directement à partir du plan d'étage — dessinez les pièces, placez les appareils par glisser-déposer, les symboles RGIE sont utilisés automatiquement. ",[203,18515,18516],{"href":7861},"Essayer gratuitement →",{"title":1212,"searchDepth":1213,"depth":1213,"links":18518},[18519,18523,18524,18531,18532,18533,18534,18535,18536,18537,18538],{"id":17738,"depth":1213,"text":17739,"children":18520},[18521,18522],{"id":17742,"depth":5848,"text":17743},{"id":17775,"depth":5848,"text":17776},{"id":17887,"depth":1213,"text":17888},{"id":18073,"depth":1213,"text":18074,"children":18525},[18526,18527,18528,18529,18530],{"id":18080,"depth":5848,"text":18081},{"id":18117,"depth":5848,"text":18118},{"id":18141,"depth":5848,"text":18142},{"id":18162,"depth":5848,"text":18163},{"id":18169,"depth":5848,"text":18170},{"id":18194,"depth":1213,"text":18195},{"id":18259,"depth":1213,"text":18260},{"id":5265,"depth":1213,"text":5266},{"id":18386,"depth":1213,"text":18387},{"id":18453,"depth":1213,"text":18454},{"id":18466,"depth":1213,"text":18467},{"id":10008,"depth":1213,"text":10009},{"id":10023,"depth":1213,"text":10024},"2026-03-30","Guide complet pour préparer un plan de situation vérifiable : plan d'étage, symboles RGIE, références de circuits et contrôle professionnel.",{},"\u002Fblog\u002Fdraw-situation-plan.fr",{"title":17704,"description":18540},"dessiner-plan-situation-guide","blog\u002Fdraw-situation-plan.fr",[8422,1242,18547,1228,18548,18549,18550],"symboles","dessin","plan électrique","plan d'étage","0DsnGLD1kt8JxB2vtO-3DC_dtbOB7BM1DKJOaH5m2zA",{"id":18553,"title":18554,"articleId":18555,"body":18556,"category":10248,"date":18833,"description":18834,"extension":1231,"lastUpdated":18833,"locale":1232,"meta":18835,"navigation":1234,"path":18836,"publishDate":18833,"readTime":10253,"refreshInterval":1237,"seo":18837,"slug":18838,"stem":18839,"tags":18840,"__hash__":18845},"blog\u002Fblog\u002Fpreflex-vs-open-wiring.fr.md","Preflex vs. pose libre : Quelle méthode de câblage pour votre projet ?","preflex-vs-open-wiring",{"type":9,"value":18557,"toc":18824},[18558,18562,18567,18571,18574,18578,18689,18693,18713,18717,18737,18741,18760,18767,18771,18791,18793,18795,18812,18814],[12928,18559,18561],{"id":18560},"preflex-vs-pose-libre-quelle-méthode-convient-à-votre-projet","Preflex vs. pose libre : Quelle méthode convient à votre projet ?",[17,18563,18564,18566],{},[221,18565,7404],{}," Le Preflex est une gaine préfabriquée avec des câbles déjà tirés — idéal pour la construction neuve, où il est directement coulé dans le béton. La pose libre (par ex. XVB en apparent ou en goulotte) convient mieux aux rénovations, où les gaines sont difficiles à installer après coup.",[12,18568,18570],{"id":18569},"quest-ce-que-le-preflex","Qu'est-ce que le Preflex ?",[17,18572,18573],{},"Le Preflex est un tube annelé flexible (gaine d'attente) dans lequel les câbles appropriés sont déjà tirés en usine. En Belgique, cette méthode est extrêmement répandue dans la construction neuve : les gaines sont posées pendant la phase de gros œuvre sur la dalle en béton ou dans la chape, puis coulées. Les câbles sont ainsi entièrement protégés et remplaçables ultérieurement si nécessaire.",[12,18575,18577],{"id":18576},"comparaison-preflex-safe-vs-preflex-normal-vs-pose-libre","Comparaison : Preflex Safe vs. Preflex normal vs. pose libre",[21,18579,18580,18595],{},[24,18581,18582],{},[27,18583,18584,18586,18589,18592],{},[30,18585,7958],{},[30,18587,18588],{},"Preflex Safe",[30,18590,18591],{},"Preflex normal",[30,18593,18594],{},"Pose libre (XVB)",[43,18596,18597,18613,18629,18644,18658,18673],{},[27,18598,18599,18604,18607,18610],{},[48,18600,18601],{},[221,18602,18603],{},"Gaine",[48,18605,18606],{},"Sans halogène (LSOH)",[48,18608,18609],{},"PVC standard",[48,18611,18612],{},"Pas de gaine, câble direct",[27,18614,18615,18620,18623,18626],{},[48,18616,18617],{},[221,18618,18619],{},"Classe CPR",[48,18621,18622],{},"Cca-s1,d1,a1 (câble dans conduit)",[48,18624,18625],{},"Eca (câble dans conduit ; la classe CPR se réfère au câble, pas au conduit lui-même)",[48,18627,18628],{},"XVB avec marquage CPR Cca-s1,d2,a1 (exigé dans certains modes de pose pour les nouvelles installations ; les stocks anciens peuvent encore être classés Eca)",[27,18630,18631,18635,18638,18641],{},[48,18632,18633],{},[221,18634,7594],{},[48,18636,18637],{},"Neuf, bâtiments publics",[48,18639,18640],{},"Neuf résidentiel",[48,18642,18643],{},"Rénovation, apparent",[27,18645,18646,18651,18653,18655],{},[48,18647,18648],{},[221,18649,18650],{},"Remplacement câble",[48,18652,8064],{},[48,18654,8064],{},[48,18656,18657],{},"Non (installation fixe)",[27,18659,18660,18664,18667,18670],{},[48,18661,18662],{},[221,18663,14183],{},[48,18665,18666],{},"Le plus élevé",[48,18668,18669],{},"Moyen",[48,18671,18672],{},"Le plus bas",[27,18674,18675,18680,18683,18686],{},[48,18676,18677],{},[221,18678,18679],{},"Conformité RGIE",[48,18681,18682],{},"Toutes applications",[48,18684,18685],{},"Résidentiel autorisé",[48,18687,18688],{},"Toutes applications (si type de câble correct)",[12,18690,18692],{"id":18691},"avantages-du-preflex","Avantages du Preflex",[711,18694,18695,18701,18707],{},[714,18696,18697,18700],{},[221,18698,18699],{},"Installation soignée :"," Pas de câbles visibles, tout est encastré ou coulé.",[714,18702,18703,18706],{},[221,18704,18705],{},"Pérennité :"," Les câbles peuvent être remplacés ou ajoutés ultérieurement sans casser les murs.",[714,18708,18709,18712],{},[221,18710,18711],{},"Protection :"," La gaine protège contre les dommages mécaniques.",[12,18714,18716],{"id":18715},"inconvénients-du-preflex","Inconvénients du Preflex",[711,18718,18719,18725,18731],{},[714,18720,18721,18724],{},[221,18722,18723],{},"Plus cher"," que la pose directe de câbles (matériel + main-d'œuvre).",[714,18726,18727,18730],{},[221,18728,18729],{},"Uniquement en construction neuve\u002Frénovation lourde"," — difficilement installable lors d'une simple rénovation.",[714,18732,18733,18736],{},[221,18734,18735],{},"Rayons de courbure"," à respecter : des courbes trop serrées compliquent le retirage ultérieur.",[12,18738,18740],{"id":18739},"que-dit-le-rgie","Que dit le RGIE ?",[17,18742,18743,18744,18747,18748,18751,18752,18755,18756,18759],{},"Le RGIE ne prescrit pas de méthode d'installation particulière — les deux sont autorisées. Ce qui compte, c'est la ",[221,18745,18746],{},"classe de réaction au feu"," (règlement CPR) : les câbles posés individuellement doivent avoir au minimum ",[221,18749,18750],{},"Eca"," (art. 5.2.7.2). En ",[221,18753,18754],{},"faisceaux, cloisons creuses et cavités constructives",", la classe minimale ",[221,18757,18758],{},"Cca"," est exigée (art. 5.2.7.3, art. 4.3.3.5b). Attention : les murs à ossature bois (fréquents en rénovation) comptent comme cavité constructive !",[17,18761,18762,18763,18766],{},"Le conduit ne doit pas être rempli à plus de ",[221,18764,18765],{},"40 %"," par des câbles (règle d'installation générale selon les règles de l'art), afin de permettre le retirage ultérieur.",[12,18768,18770],{"id":18769},"quelle-méthode-choisir","Quelle méthode choisir ?",[711,18772,18773,18779,18785],{},[714,18774,18775,18778],{},[221,18776,18777],{},"Construction neuve"," → Preflex (Safe pour la meilleure protection incendie)",[714,18780,18781,18784],{},[221,18782,18783],{},"Rénovation"," → Câble XVB en goulotte ou en apparent",[714,18786,18787,18790],{},[221,18788,18789],{},"Rénovation partielle"," → Combinaison possible (nouveaux circuits en Preflex, existants conservés)",[7849,18792],{},[12,18794,10024],{"id":10023},[711,18796,18797,18801,18807],{},[714,18798,18799],{},[203,18800,16343],{"href":16342},[714,18802,18803],{},[203,18804,18806],{"href":18805},"\u002Ffr\u002Fblog\u002Fsalle-de-bain-cables-rgie-zones","Électricité salle de bain : Zones et types de câbles",[714,18808,18809],{},[203,18810,18811],{"href":10031},"Ancien bâtiment et RGIE Partie 8",[7849,18813],{},[17,18815,18816],{},[60,18817,18818,18819,18821,18822],{},"Planifiez votre installation électrique avec ",[221,18820,5823],{}," — en construction neuve avec Preflex ou en rénovation avec pose libre — puis exportez le schéma unifilaire et le plan de situation. L'auto-contrôle reste indicatif. ",[203,18823,16365],{"href":7861},{"title":1212,"searchDepth":1213,"depth":1213,"links":18825},[18826,18827,18828,18829,18830,18831,18832],{"id":18569,"depth":1213,"text":18570},{"id":18576,"depth":1213,"text":18577},{"id":18691,"depth":1213,"text":18692},{"id":18715,"depth":1213,"text":18716},{"id":18739,"depth":1213,"text":18740},{"id":18769,"depth":1213,"text":18770},{"id":10023,"depth":1213,"text":10024},"2026-03-27","Comparaison des gaines Preflex et de la pose libre de câbles en Belgique. Avantages, inconvénients et classes de réaction au feu RGIE.",{},"\u002Fblog\u002Fpreflex-vs-open-wiring.fr",{"title":18554,"description":18834},"preflex-vs-pose-libre","blog\u002Fpreflex-vs-open-wiring.fr",[18841,18842,6254,10089,1242,18843,18844],"preflex","câblage","sécurité incendie","XVB","48j9FIfLvdN3Kks8yUI2zJD2hC2yKxhXAJmYWRrJ4js",{"id":18847,"title":18848,"articleId":18849,"body":18850,"category":10248,"date":19172,"description":19173,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":19174,"navigation":1234,"path":19175,"publishDate":19172,"readTime":8416,"refreshInterval":1237,"seo":19176,"slug":19177,"stem":19178,"tags":19179,"__hash__":19184},"blog\u002Fblog\u002Frcd-type-a-vs-b.fr.md","Différentiel type A ou type B en 2026 : lequel choisir ?","rcd-type-a-vs-b",{"type":9,"value":18851,"toc":19157},[18852,18855,18858,18861,18865,18879,18883,18963,18967,18978,18981,18985,18988,18992,18995,18998,19002,19005,19008,19014,19018,19021,19025,19028,19048,19052,19097,19101,19104,19108,19128,19132,19154],[12928,18853,18848],{"id":18854},"différentiel-type-a-ou-type-b-en-2026-lequel-choisir",[17,18856,18857],{},"Dans une installation domestique belge en courant alternatif, le RGIE Livre 1 version 06 exige des dispositifs différentiels au moins de type A. Cette règle ne signifie ni que le type A convient à tout équipement, ni que chaque appareil électronique impose un type B. Les formes de courant de défaut, les protections internes et la notice du modèle déterminent ensemble le choix.",[17,18859,18860],{},"Ce guide couvre les installations domestiques AC. Les schémas DC mis à la terre ajoutés depuis le 1er avril 2026 sont un autre domaine.",[12,18862,18864],{"id":18863},"forme-donde-immunité-et-sélectivité","Forme d'onde, immunité et sélectivité",[17,18866,1530,18867,18870,18871,18874,18875,18878],{},[221,18868,18869],{},"type AC, A, F ou B"," définit les courants résiduels couverts. Les mentions ",[221,18872,18873],{},"SI, HI ou AP-R"," sont des désignations de fabricants pour une immunité renforcée. La ",[221,18876,18877],{},"sélectivité ou temporisation"," décrit le comportement dans le temps face à un appareil aval et requiert un marquage S ou une courbe documentée. Un A-SI peut être instantané : il n'est pas automatiquement sélectif.",[12,18880,18882],{"id":18881},"aperçu-de-tous-les-types-de-ddr","Aperçu de tous les types de DDR",[21,18884,18885,18897],{},[24,18886,18887],{},[27,18888,18889,18891,18894],{},[30,18890,16673],{},[30,18892,18893],{},"Détecte",[30,18895,18896],{},"Domaine d'application",[43,18898,18899,18912,18925,18938,18950],{},[27,18900,18901,18906,18909],{},[48,18902,18903],{},[221,18904,18905],{},"AC",[48,18907,18908],{},"Uniquement les courants de défaut alternatifs purs",[48,18910,18911],{},"Ne satisfait pas au minimum type A d'une nouvelle installation domestique",[27,18913,18914,18919,18922],{},[48,18915,18916],{},[221,18917,18918],{},"A",[48,18920,18921],{},"Alternatif et continu pulsé",[48,18923,18924],{},"Classe minimale domestique ; les instructions des appareils restent à vérifier",[27,18926,18927,18932,18935],{},[48,18928,18929],{},[221,18930,18931],{},"A-SI",[48,18933,18934],{},"Comme type A",[48,18936,18937],{},"Immunité renforcée, pas nécessairement sélectif",[27,18939,18940,18944,18947],{},[48,18941,18942],{},[221,18943,3683],{},[48,18945,18946],{},"Aussi le continu lisse",[48,18948,18949],{},"Quand la conception et le fabricant l'exigent",[27,18951,18952,18957,18960],{},[48,18953,18954],{},[221,18955,18956],{},"F",[48,18958,18959],{},"Certaines fréquences mixtes supplémentaires",[48,18961,18962],{},"Pour des charges monophasées spécifiées",[12,18964,18966],{"id":18965},"quatre-caractéristiques-indépendantes","Quatre caractéristiques indépendantes",[17,18968,18969,18970,18973,18974,18977],{},"Le type ne répond qu'à la question de la forme d'onde. ",[4068,18971,18972],{},"IΔn"," (30 ou 300 mA, par exemple) est la sensibilité différentielle. ",[4068,18975,18976],{},"In"," (40 ou 63 A) est le courant que l'appareil peut transporter en permanence ; ce n'est pas un seuil de surcharge. Un DDR sans fonction de surintensité exige donc une protection coordonnée. Son pouvoir de coupure ou son courant conditionnel de court-circuit doit également convenir au point d'installation.",[17,18979,18980],{},"Nombre de pôles, tension et câblage comptent aussi. Tous les conducteurs actifs du circuit protégé passent dans le tore et les neutres de groupes différents ne doivent pas être mélangés. Le bouton de test vérifie un circuit interne du DDR ; il ne mesure pas la terre et ne valide pas toute la mesure de protection. Les contrôles réglementaires comprennent d'autres essais.",[5686,18982,18984],{"id":18983},"neuf-modification-ou-installation-existante","Neuf, modification ou installation existante ?",[17,18986,18987],{},"Le minimum type A est la base du neuf domestique. Dans l'existant, il faut examiner la date, les dérogations de la partie 8 et la portée d'une modification ou extension. Un ancien type AC ne peut donc être déclaré généralement acceptable sans cette analyse, mais sa seule présence ne prouve pas non plus que toute l'installation est inutilisable.",[12,18989,18991],{"id":18990},"partir-du-circuit-et-de-la-notice-pas-dun-slogan","Partir du circuit et de la notice, pas d'un slogan",[17,18993,18994],{},"“PV égale type B” ou “domestique égale type A” ne suffit pas pour concevoir. Une pompe à chaleur peut combiner compresseur, appoint et commande avec des exigences différentes. Pour le photovoltaïque, topologie de l'onduleur, surveillance interne et raccordement sont déterminants. Pour la recharge, il faut savoir si la borne intègre un RDC-DD et avec quel DDR externe il peut être coordonné. Plusieurs charges électroniques derrière le même DDR imposent aussi d'examiner le cumul des courants de fuite normaux et des composantes continues possibles.",[17,18996,18997],{},"Un type F ou B n'est pas simplement “meilleur” qu'un type A. Sa couverture de formes d'onde ne remplace ni sensibilité correcte, courant assigné, temps de coupure, protection contre les surintensités ou câblage. Une prescription relative à un appareil ne s'étend pas automatiquement à tout le tableau : la chaîne complète doit rester cohérente.",[12,18999,19001],{"id":19000},"diagnostiquer-les-déclenchements-indésirables","Diagnostiquer les déclenchements indésirables",[17,19003,19004],{},"Remplacer immédiatement un DDR par une version SI n'explique pas un déclenchement. Il faut d'abord rechercher défaut d'isolement, humidité, neutres mélangés, fuites cumulées ou erreur de câblage. Une immunité renforcée peut ensuite être choisie si sa notice couvre le phénomène, sans réduire la protection des personnes.",[17,19006,19007],{},"Dans une cascade, les tableaux de coordination des fabricants comptent davantage que les seuls marquages 300 et 30 mA. L'amont sélectif doit posséder la courbe adaptée et l'aval couper dans le délai prescrit. Une marge suffisante entre les fuites normales cumulées et la zone de déclenchement améliore également la robustesse, sans constituer une garantie absolue.",[17,19009,19010,19011,19013],{},"Un disjoncteur différentiel (RCBO) peut réunir protection différentielle et surintensité pour un circuit terminal. Sa classe de forme d'onde doit néanmoins convenir à la charge et sa coordination avec le DDR amont reste à vérifier. Pour un DDR séparé, ",[4068,19012,18976],{}," n'est pas une protection contre la surcharge. Calibre amont, tableau et courants de charge possibles se dimensionnent ensemble. La référence exacte et sa notice, pas seulement “30 mA type A”, doivent rester dans le dossier.",[12,19015,19017],{"id":19016},"quand-le-type-b-est-il-requis","Quand le Type B est-il requis ?",[17,19019,19020],{},"Le type B est pertinent si un courant continu lisse est possible et qu'aucune autre combinaison admise ne couvre le risque. Pour une pompe à chaleur ou un onduleur PV, il faut vérifier les formes indiquées par le fabricant, la surveillance DC interne, le type externe prescrit et la coordination de plusieurs convertisseurs. « Inverter » ou « sans transformateur » ne crée pas une obligation générale de type B.",[12,19022,19024],{"id":19023},"quand-le-type-a-suffit-il","Quand le Type A suffit-il ?",[17,19026,19027],{},"Le Type A est suffisant pour :",[711,19029,19030,19036,19042],{},[714,19031,19032,19035],{},[221,19033,19034],{},"Point de charge avec détection DC coordonnée :"," le RGIE 7.22.4.1.b exige un différentiel individuel de 30 mA maximum par circuit AC séparé, puis soit un dispositif restant opérationnel face à la composante DC, tel qu'un type B adapté, soit un différentiel coordonné avec une détection DC résiduelle, par exemple type A plus RDC-DD. Les éléments peuvent être dans l'installation, la borne ou les deux.",[714,19037,19038,19041],{},[221,19039,19040],{},"Appareils ménagers normaux :"," Machine à laver, lave-vaisselle, plaque de cuisson, éclairage",[714,19043,19044,19047],{},[221,19045,19046],{},"Circuits prises de courant :"," DDR standard 30 mA Type A",[12,19049,19051],{"id":19050},"exigences-rgie","Exigences RGIE",[21,19053,19054,19064],{},[24,19055,19056],{},[27,19057,19058,19061],{},[30,19059,19060],{},"Article RGIE",[30,19062,19063],{},"Exigence",[43,19065,19066,19074,19081,19089],{},[27,19067,19068,19071],{},[48,19069,19070],{},"Art. 4.2.4.3_b",[48,19072,19073],{},"Protection de 300 mA maximum à l'origine, puis haute ou très haute sensibilité pour les circuits domestiques énumérés",[27,19075,19076,19078],{},[48,19077,19070],{},[48,19079,19080],{},"Maximum 8 circuits départ par DDR 30 mA",[27,19082,19083,19086],{},[48,19084,19085],{},"Art. 5.3.5.3_a",[48,19087,19088],{},"Dispositifs de protection à courant différentiel résiduel dans les installations domestiques au minimum Type A ; au point d'alimentation au minimum 40 A de courant nominal",[27,19090,19091,19094],{},[48,19092,19093],{},"Art. 7.22",[48,19095,19096],{},"Borne de recharge : circuit dédié avec DDR approprié",[12,19098,19100],{"id":19099},"respecter-la-sélectivité","Respecter la sélectivité",[17,19102,19103],{},"La succession 300 mA puis 30 mA ne garantit pas la sélectivité. Il faut vérifier le rapport des sensibilités, une caractéristique amont explicitement sélective ou correctement temporisée, la combinaison admise, les temps de coupure et les fuites normales. L'immunité renforcée ne remplace pas cette coordination. Sans preuve, il est impossible de garantir que seul l'appareil aval déclenchera.",[12,19105,19107],{"id":19106},"sélection-en-six-étapes","Sélection en six étapes",[5034,19109,19110,19113,19116,19119,19122,19125],{},[714,19111,19112],{},"Identifier circuit et équipements.",[714,19114,19115],{},"Fixer la sensibilité imposée par le RGIE.",[714,19117,19118],{},"Lire les exigences de chaque fabricant sur les courants de défaut et la détection DC.",[714,19120,19121],{},"Vérifier la coordination des références en cascade.",[714,19123,19124],{},"Documenter type, sensibilité, courant assigné et éventuelle temporisation.",[714,19126,19127],{},"Faire contrôler l'exécution par un organisme agréé.",[12,19129,19131],{"id":19130},"sources-et-articles-associés","Sources et articles associés",[711,19133,19134,19139,19144,19149],{},[714,19135,19136],{},[203,19137,19138],{"href":12505},"Réglementation RGIE 2026",[714,19140,19141],{},[203,19142,19143],{"href":10208},"Faut-il un différentiel 30 mA par prise ?",[714,19145,19146],{},[203,19147,19148],{"href":8765},"Installer une borne selon le RGIE",[714,19150,19151],{},[203,19152,19153],{"href":1204},"Démarrer dans PlanElec",[17,19155,19156],{},"Sources primaires : RGIE Livre 1 version 06, 4.2.4.3.b, 5.3.5.3.a et 7.22.4.1.b, plus la FAQ de la Direction générale de l'Énergie relative à l'arrêté royal du 5 mars 2023. PlanElec documente les caractéristiques dans le projet, le schéma et le PDF et signale certains cas pris en charge dans un auto-contrôle indicatif. Il ne remplace ni l'étude professionnelle ni le contrôle officiel.",{"title":1212,"searchDepth":1213,"depth":1213,"links":19158},[19159,19160,19161,19164,19165,19166,19167,19168,19169,19170,19171],{"id":18863,"depth":1213,"text":18864},{"id":18881,"depth":1213,"text":18882},{"id":18965,"depth":1213,"text":18966,"children":19162},[19163],{"id":18983,"depth":5848,"text":18984},{"id":18990,"depth":1213,"text":18991},{"id":19000,"depth":1213,"text":19001},{"id":19016,"depth":1213,"text":19017},{"id":19023,"depth":1213,"text":19024},{"id":19050,"depth":1213,"text":19051},{"id":19099,"depth":1213,"text":19100},{"id":19106,"depth":1213,"text":19107},{"id":19130,"depth":1213,"text":19131},"2026-03-25","Types de différentiels pour une installation domestique belge selon le RGIE Livre 1 version 06 : type A, type B, détection DC, immunité et sélectivité.",{},"\u002Fblog\u002Frcd-type-a-vs-b.fr",{"title":18848,"description":19173},"differentiel-type-a-vs-type-b","blog\u002Frcd-type-a-vs-b.fr",[11817,19180,19181,19182,8832,19183],"ddr","type-a","type-b","borne-de-recharge","lPxXkm5hJzikBehJKlrLPZBmBYlYD5UqTyzcpm6uOLA",{"id":19186,"title":19187,"articleId":19188,"body":19189,"category":10248,"date":19366,"description":19367,"extension":1231,"lastUpdated":13185,"locale":1232,"meta":19368,"navigation":1234,"path":19369,"publishDate":19366,"readTime":19370,"refreshInterval":1237,"seo":19371,"slug":19372,"stem":19373,"tags":19374,"__hash__":19378},"blog\u002Fblog\u002Fmain-switch-mandatory.fr.md","Interrupteur général obligatoire : Que prescrit le RGIE ?","main-switch-mandatory",{"type":9,"value":19190,"toc":19358},[19191,19194,19200,19204,19207,19239,19243,19278,19282,19285,19299,19303,19310,19313,19330,19334,19341,19348,19350],[12928,19192,19187],{"id":19193},"interrupteur-général-obligatoire-que-prescrit-le-rgie",[17,19195,19196,19199],{},[221,19197,19198],{},"Oui, un interrupteur général est obligatoire en Belgique."," Selon le RGIE Art. 5.3.5.1b, chaque ensemble d'appareillage principal doit disposer d'un interrupteur-sectionneur principal omnipolaire permettant la coupure simultanée de tous les conducteurs actifs et éventuellement du neutre. Le RGIE prescrit un courant nominal d'au moins 40 A pour les installations domestiques (Art. 5.3.5.1b) ; le minimum général est de 25 A. En pratique, un interrupteur-sectionneur est utilisé comme interrupteur principal. Contrairement à un simple sectionneur, il peut être manoeuvré en charge.",[12,19201,19203],{"id":19202},"exigences-pour-linterrupteur-général","Exigences pour l'interrupteur général",[17,19205,19206],{},"L'interrupteur général doit satisfaire les conditions suivantes :",[711,19208,19209,19215,19221,19227,19233],{},[714,19210,19211,19214],{},[221,19212,19213],{},"Omnipolaire :"," Pour un raccordement monophasé, 2 pôles (phase + neutre) ; pour un raccordement triphasé, 4 pôles (3 phases + neutre)",[714,19216,19217,19220],{},[221,19218,19219],{},"Courant nominal au moins 40 A"," pour les installations domestiques (Art. 5.3.5.1b), adapté à l'installation concernée",[714,19222,19223,19226],{},[221,19224,19225],{},"Couper toute l'installation :"," Une seule manoeuvre doit séparer tous les conducteurs actifs",[714,19228,19229,19232],{},[221,19230,19231],{},"Facilement accessible :"," Hauteur de manoeuvre max. 1,80 m (valeur pratique des organismes de contrôle — le RGIE exige uniquement que les ensembles d'appareillage soient 'facilement accessibles sans moyens particuliers' (Art. 5.3.5.1c), sans préciser de hauteur exacte)",[714,19234,19235,19238],{},[221,19236,19237],{},"À l'entrée de l'installation :"," Avant le tableau de distribution, comme premier organe de coupure après le compteur",[12,19240,19242],{"id":19241},"articles-rgie","Articles RGIE",[21,19244,19245,19253],{},[24,19246,19247],{},[27,19248,19249,19251],{},[30,19250,19060],{},[30,19252,19063],{},[43,19254,19255,19263,19270],{},[27,19256,19257,19260],{},[48,19258,19259],{},"Art. 5.3.5.1b",[48,19261,19262],{},"Interrupteur-sectionneur principal obligatoire, omnipolaire, sur l'ensemble d'appareillage principal",[27,19264,19265,19267],{},[48,19266,19259],{},[48,19268,19269],{},"Courant nominal au moins 40 A pour les installations domestiques, adapté à l'installation concernée",[27,19271,19272,19275],{},[48,19273,19274],{},"Art. 5.3.5.1c",[48,19276,19277],{},"Les ensembles d'appareillage doivent être facilement accessibles et manoeuvrables",[12,19279,19281],{"id":19280},"pourquoi-linterrupteur-général-est-il-si-important","Pourquoi l'interrupteur général est-il si important ?",[17,19283,19284],{},"L'interrupteur général remplit deux fonctions centrales :",[5034,19286,19287,19293],{},[714,19288,19289,19292],{},[221,19290,19291],{},"Coupure d'urgence :"," En cas d'urgence (incendie, inondation, électrocution), tout occupant doit pouvoir couper l'ensemble de l'installation d'une seule manoeuvre — même sans connaissances en électricité.",[714,19294,19295,19298],{},[221,19296,19297],{},"Maintenance :"," Pour les travaux sur l'installation électrique, l'ensemble de l'installation doit pouvoir être mise hors tension en toute sécurité.",[12,19300,19302],{"id":19301},"défaut-fréquent-au-contrôle","Défaut fréquent au contrôle",[17,19304,19305,19306,19309],{},"L'interrupteur général absent ou mal dimensionné est l'un des ",[221,19307,19308],{},"défauts les plus fréquents lors du contrôle électrique"," en Belgique. Surtout dans les anciennes installations, il est souvent totalement absent, ou seul un interrupteur unipolaire est installé, qui ne coupe pas le neutre.",[17,19311,19312],{},"Défauts typiques :",[711,19314,19315,19318,19321,19324,19327],{},[714,19316,19317],{},"Aucun interrupteur général présent",[714,19319,19320],{},"Unipolaire au lieu d'omnipolaire",[714,19322,19323],{},"Courant nominal inférieur à 40 A dans une installation domestique",[714,19325,19326],{},"Monté trop haut (pas facilement accessible)",[714,19328,19329],{},"Pas facilement accessible (derrière des meubles, dans un local fermé)",[12,19331,19333],{"id":19332},"interrupteur-général-vs-disjoncteur-principal","Interrupteur général vs. disjoncteur principal",[17,19335,19336,19337,19340],{},"L'interrupteur général n'est ",[221,19338,19339],{},"pas un disjoncteur"," — il n'a pas de fonction de protection contre les surintensités. Il sert exclusivement d'interrupteur de sectionnement. La protection contre les surintensités est assurée par le gestionnaire de réseau (fusible avant le compteur) et les disjoncteurs en aval dans le tableau.",[17,19342,19343,19344,19347],{},"Cependant, un ",[221,19345,19346],{},"disjoncteur principal"," (p.ex. 40 A) peut combiner les deux fonctions : sectionnement et protection contre les surintensités.",[12,19349,10024],{"id":10023},[17,19351,19352,19353,19357],{},"Planifiez votre tableau avec ",[203,19354,5823],{"href":19355,"rel":19356},"https:\u002F\u002Fwww.planelec.be",[5373],". L'auto-contrôle peut signaler certaines configurations prises en charge, mais ne remplace pas la vérification professionnelle ou le contrôle officiel.",{"title":1212,"searchDepth":1213,"depth":1213,"links":19359},[19360,19361,19362,19363,19364,19365],{"id":19202,"depth":1213,"text":19203},{"id":19241,"depth":1213,"text":19242},{"id":19280,"depth":1213,"text":19281},{"id":19301,"depth":1213,"text":19302},{"id":19332,"depth":1213,"text":19333},{"id":10023,"depth":1213,"text":10024},"2026-03-23","Pourquoi l'interrupteur général est obligatoire en Belgique et quelles exigences le RGIE Art. 5.3.5.1b impose.",{},"\u002Fblog\u002Fmain-switch-mandatory.fr","4 min",{"title":19187,"description":19367},"interrupteur-general-obligatoire-rgie","blog\u002Fmain-switch-mandatory.fr",[19375,8832,19376,19377,11816],"interrupteur-general","obligatoire","tableau","Jb2Cgp2et-0vI5Rp5uoV9DKLsbIvIx1fXlHsQ_gLDe4",{"id":19380,"title":19381,"articleId":19382,"body":19383,"category":10248,"date":19690,"description":19691,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":19692,"navigation":1234,"path":19693,"publishDate":19690,"readTime":8416,"refreshInterval":1237,"seo":19694,"slug":19695,"stem":19696,"tags":19697,"__hash__":19700},"blog\u002Fblog\u002Fearthing-tt-vs-tns.fr.md","Mise à la terre TT ou TN-S en 2026 : protection selon le RGIE V06","earthing-tt-vs-tns",{"type":9,"value":19384,"toc":19678},[19385,19389,19396,19403,19407,19414,19456,19459,19463,19466,19469,19474,19495,19499,19509,19512,19516,19522,19525,19529,19573,19576,19580,19583,19586,19590,19599,19602,19606,19609,19612,19638,19642,19645,19648,19652,19669,19673],[12928,19386,19388],{"id":19387},"tt-ou-tn-s-suivre-la-boucle-de-défaut-plutôt-quune-réputation","TT ou TN-S : suivre la boucle de défaut plutôt qu'une réputation",[17,19390,19391,19392,19395],{},"TT et TN-S indiquent comment le point mis à la terre de la source et les masses de l'installation sont reliés. Cette architecture détermine le trajet du courant de défaut et les conditions de coupure. ",[221,19393,19394],{},"Le RGIE ne proclame pas le TT “standard résidentiel belge” et ne réserve pas le TN-S au neuf ou à l'industrie."," Il faut identifier le réseau réellement fourni à l'adresse concernée ; l'âge ou l'usage du bâtiment ne suffit pas.",[17,19397,19398,19399,19402],{},"Ce guide vise les installations domestiques en ",[221,19400,19401],{},"courant alternatif"," couvertes par le Livre 1, version 06, applicable depuis le 1er avril 2026. Les nouvelles dispositions V06 relatives au courant continu constituent un domaine séparé.",[12,19404,19406],{"id":19405},"lire-les-lettres-du-régime-de-neutre","Lire les lettres du régime de neutre",[17,19408,19409,19410,19413],{},"La première lettre décrit le lien entre la source et la terre. ",[4068,19411,19412],{},"T"," signifie qu'un point de la source est directement relié à la terre. La seconde décrit les masses de l'installation utilisatrice :",[711,19415,19416,19422,19428,19442],{},[714,19417,19418,19421],{},[221,19419,19420],{},"TT"," : les masses sont reliées à une prise de terre locale, indépendante de celle de la source ;",[714,19423,19424,19427],{},[221,19425,19426],{},"TN"," : elles sont reliées au point mis à la terre de la source par des conducteurs de protection ;",[714,19429,19430,19433,19434,19437,19438,19441],{},[221,19431,19432],{},"TN-S"," : le neutre ",[4068,19435,19436],{},"N"," et le conducteur de protection ",[4068,19439,19440],{},"PE"," restent séparés ;",[714,19443,19444,19447,19448,19451,19452,207,19454,212],{},[221,19445,19446],{},"TN-C-S"," : un conducteur combiné ",[4068,19449,19450],{},"PEN"," existe sur une partie, puis est séparé en ",[4068,19453,19440],{},[4068,19455,19436],{},[17,19457,19458],{},"On ne peut pas conclure “TN-C-S parce que la maison est ancienne”. La connexion, le cheminement des conducteurs et les informations du gestionnaire de réseau doivent être vérifiés.",[12,19460,19462],{"id":19461},"en-tt-prise-de-terre-locale-et-ddr","En TT : prise de terre locale et DDR",[17,19464,19465],{},"Lors d'un défaut d'isolement, le courant retourne vers le point de la source mis à la terre en passant par la masse, le conducteur de protection, la prise de terre locale et le sol. L'impédance de cette boucle peut empêcher un disjoncteur de surintensité de déclencher assez vite. La coupure automatique en TT repose donc généralement sur des dispositifs différentiels résiduels.",[17,19467,19468],{},"La condition fondamentale est :",[17,19470,19471],{},[4068,19472,19473],{},"IΔn × R_E ≤ U_L",[17,19475,19476,19478,19479,19482,19483,19486,19487,19490,19491,19494],{},[4068,19477,18972],{}," est le courant différentiel assigné du DDR, ",[4068,19480,19481],{},"R_E"," la résistance de dispersion de l'installation et ",[4068,19484,19485],{},"U_L"," la tension limite conventionnelle. Le calcul ",[4068,19488,19489],{},"50 V \u002F 0,3 A ≈ 166 Ω"," n'annule pas l'exigence domestique spécifique de ",[221,19492,19493],{},"moins de 100 Ω",". Une protection contre les surintensités peut en principe assurer la coupure en TT si toutes les conditions d'impédance et de temps sont réellement remplies. Dire que le TT ne fonctionne “que par différentiel” serait donc excessif, même si le DDR est la solution usuelle.",[12,19496,19498],{"id":19497},"en-tn-s-retour-métallique-par-le-pe","En TN-S : retour métallique par le PE",[17,19500,19501,19502,19504,19505,19508],{},"Le courant de défaut revient au point source via le ",[4068,19503,19440],{},". La boucle doit être assez peu impédante pour faire déclencher la protection dans le délai prescrit. La relation simplifiée est ",[4068,19506,19507],{},"Zs × Ia ≤ U0"," : impédance de boucle multipliée par le courant assurant le déclenchement, comparée à la tension phase-terre.",[17,19510,19511],{},"Cela ne signifie pas que le gestionnaire “garantit une résistance de terre”, ni que les DDR deviennent inutiles. Les obligations domestiques de la section 4.2.4.3 s'appliquent aussi en TN-S. Inversement, un DDR 30 mA ne remplace pas les contrôles de continuité du PE et des conditions de coupure.",[12,19513,19515],{"id":19514},"une-prise-de-terre-locale-peut-rester-nécessaire-en-tn","Une prise de terre locale peut rester nécessaire en TN",[17,19517,19518,19519,19521],{},"La présence d'un ",[4068,19520,19440],{}," fourni par le réseau ne permet pas de supprimer sans étude la prise de terre de l'installation. Le Livre 1 impose, pour les installations domestiques, une résistance de dispersion inférieure à 100 Ω. Conducteur de terre, borne principale, barrette de coupure et liaisons équipotentielles doivent être durables, accessibles et contrôlables.",[17,19523,19524],{},"Le choix d'une boucle, d'une prise de fondation ou de piquets dépend du neuf, de l'existant, des fondations et du sol. Les sections examinées ne donnent pas une règle universelle “tout piquet mesure au moins 1,50 m”. C'est la solution réglementaire complète et sa mesure qui comptent.",[12,19526,19528],{"id":19527},"les-seuils-de-30-ω-et-100-ω-ne-jouent-pas-le-même-rôle","Les seuils de 30 Ω et 100 Ω ne jouent pas le même rôle",[21,19530,19531,19541],{},[24,19532,19533],{},[27,19534,19535,19538],{},[30,19536,19537],{},"Mesure",[30,19539,19540],{},"Conséquence domestique",[43,19542,19543,19553,19563],{},[27,19544,19545,19550],{},[48,19546,19547],{},[4068,19548,19549],{},"R_E \u003C 30 Ω",[48,19551,19552],{},"Les règles différentielles domestiques ordinaires s'appliquent ; ce résultat ne démontre pas à lui seul toutes les protections.",[27,19554,19555,19560],{},[48,19556,19557],{},[4068,19558,19559],{},"30 Ω \u003C R_E \u003C 100 Ω",[48,19561,19562],{},"Au moins deux DDR à haute ou très haute sensibilité, chacun alimentant au maximum 16 socles simples ou multiples, et protection des autres circuits à 100 mA au maximum.",[27,19564,19565,19570],{},[48,19566,19567],{},[4068,19568,19569],{},"R_E ≥ 100 Ω",[48,19571,19572],{},"La limite domestique n'est pas respectée ; la prise de terre doit être diagnostiquée et améliorée. Ajouter des DDR ne corrige pas ce défaut.",[17,19574,19575],{},"La limite de 16 compte les socles de prises, pas les circuits terminaux. Par ailleurs, une nouvelle installation domestique ne peut placer que huit circuits terminaux au maximum derrière un même DDR à haute ou très haute sensibilité. Les deux limites peuvent se cumuler.",[12,19577,19579],{"id":19578},"mesure-et-contrôle","Mesure et contrôle",[17,19581,19582],{},"La résistance se mesure avec un appareil et une méthode adaptés. Humidité du sol, température, corrosion, connexion desserrée ou conducteur endommagé peuvent modifier le résultat. Une inspection visuelle ne suffit pas. Le contrôle couvre aussi la continuité des conducteurs de protection, les liaisons équipotentielles, les DDR et les autres mesures contre les contacts indirects.",[17,19584,19585],{},"Le rapport de l'organisme agréé reprend la résistance mesurée. Un résultat positif ne garantit pas chaque modification ou dégradation pendant vingt-cinq ans. Ce délai concerne certaines visites périodiques domestiques ; une visite de vente négative ou un autre motif de contrôle peut entraîner un délai différent.",[12,19587,19589],{"id":19588},"terre-pe-et-équipotentialité-forment-un-ensemble","Terre, PE et équipotentialité forment un ensemble",[17,19591,19592,19593,19595,19596,19598],{},"L'électrode n'est qu'un élément. Conducteur de terre, borne principale, barrette de coupure, conducteurs de protection et liaisons équipotentielles doivent rester continus et vérifiables. Une canalisation d'eau ou de gaz ne remplace pas la prise de terre exigée. Une faible résistance ne compense pas un ",[4068,19594,19440],{}," interrompu ; une bonne continuité du ",[4068,19597,19440],{}," ne mesure pas la résistance de dispersion. Résistance, continuité, isolement, fonctionnement des DDR et coupure sont donc contrôlés séparément.",[17,19600,19601],{},"Conservez date, périmètre et rapport de mesure. Une ancienne valeur ne peut pas être transposée à une extension ou une connexion modifiée. Des chemins de terre parallèles ou une barrette inaccessible influencent la méthode et doivent être pris en compte par la personne compétente.",[12,19603,19605],{"id":19604},"que-montrer-dans-les-plans","Que montrer dans les plans ?",[17,19607,19608],{},"Le chapitre 9.1 impose notamment le schéma unifilaire, le plan de position et d'autres pièces. Il ne dit pas de façon générale que “TT” ou “TN-S” est un champ textuel obligatoire sur tout schéma. En revanche, les éléments réels doivent être représentés correctement : conducteur de terre, barrette de coupure, liaisons équipotentielles principales, dispositifs de protection et connexions pertinentes.",[17,19610,19611],{},"Pour qualifier l'installation sans deviner :",[5034,19613,19614,19617,19627,19629,19632,19635],{},[714,19615,19616],{},"vérifier le raccordement et les données du gestionnaire ;",[714,19618,19619,19620,63,19622,19624,19625,9468],{},"suivre ",[4068,19621,19436],{},[4068,19623,19440],{}," et, s'il existe, ",[4068,19626,19450],{},[714,19628,10912],{},[714,19630,19631],{},"faire mesurer résistance et continuité ;",[714,19633,19634],{},"vérifier DDR, surintensités et temps de coupure ;",[714,19636,19637],{},"comparer tableau, repérage, schéma unifilaire et plan de position à la réalité.",[12,19639,19641],{"id":19640},"tt-ou-tn-s-pas-de-classement-universel","TT ou TN-S : pas de classement universel",[17,19643,19644],{},"Les deux architectures peuvent être sûres si alimentation, conducteurs et protections forment un ensemble cohérent et contrôlé. Le TT n'est pas automatiquement plus indépendant ; le TN-S n'est pas automatiquement plus fiable. La question utile est : le défaut possède-t-il un trajet maîtrisé et l'alimentation est-elle coupée à temps ?",[17,19646,19647],{},"PlanElec permet de documenter les éléments de terre et les protections dans l'éditeur, d'exporter schéma unifilaire et plan de position en PDF et d'effectuer un auto-contrôle indicatif. Il ne mesure pas la terre, n'identifie pas automatiquement le régime et ne produit pas de rapport officiel.",[12,19649,19651],{"id":19650},"à-lire-également","À lire également",[711,19653,19654,19659,19664],{},[714,19655,19656],{},[203,19657,19658],{"href":10208},"DDR 30 mA : circuits, prises et installations existantes",[714,19660,19661],{},[203,19662,19663],{"href":5607},"Différentiel type A ou type B sans confusion",[714,19665,19666],{},[203,19667,19668],{"href":10042},"Que contrôle l'inspecteur lors de la visite ?",[17,19670,19671],{},[203,19672,11095],{"href":1204},[17,19674,19675],{},[60,19676,19677],{},"Référence : RGIE Livre 1 V06, notamment 4.2.3, 4.2.4.3, 6.5 et 9.1. Le texte officiel, les données de raccordement et les mesures de l'installation restent déterminants.",{"title":1212,"searchDepth":1213,"depth":1213,"links":19679},[19680,19681,19682,19683,19684,19685,19686,19687,19688,19689],{"id":19405,"depth":1213,"text":19406},{"id":19461,"depth":1213,"text":19462},{"id":19497,"depth":1213,"text":19498},{"id":19514,"depth":1213,"text":19515},{"id":19527,"depth":1213,"text":19528},{"id":19578,"depth":1213,"text":19579},{"id":19588,"depth":1213,"text":19589},{"id":19604,"depth":1213,"text":19605},{"id":19640,"depth":1213,"text":19641},{"id":19650,"depth":1213,"text":19651},"2026-03-20","Distinguer TT et TN-S sans raccourci : boucle de défaut, coupure automatique, prise de terre locale et seuils de 30\u002F100 ohms dans les installations domestiques AC selon le RGIE Livre 1 V06.",{},"\u002Fblog\u002Fearthing-tt-vs-tns.fr",{"title":19381,"description":19691},"mise-a-la-terre-tt-tns-belgique","blog\u002Fearthing-tt-vs-tns.fr",[11818,19698,19699,8832,11819],"systeme-tt","tn-s","EgJyTQkCWcBSCc09sG0d17tHPeUyjJzPLmF4uP-0xIY",{"id":19702,"title":19703,"articleId":19704,"body":19705,"category":10248,"date":20148,"description":20149,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":20150,"navigation":1234,"path":20151,"publishDate":20148,"readTime":8416,"refreshInterval":1237,"seo":20152,"slug":20153,"stem":20154,"tags":20155,"__hash__":20157},"blog\u002Fblog\u002Fcable-cross-section-breaker.fr.md","Section de câble par disjoncteur : quel câble pour quelle protection ?","cable-cross-section-breaker",{"type":9,"value":19706,"toc":20137},[19707,19710,19716,19720,19727,19826,19836,19840,19978,19981,19985,19999,20002,20025,20028,20032,20035,20070,20073,20077,20087,20091,20099,20103,20106,20110,20119,20121],[12928,19708,1580],{"id":19709},"section-de-câble-par-disjoncteur",[17,19711,19712,19715],{},[221,19713,19714],{},"La protection protège la canalisation, pas l’appareil raccordé."," Un disjoncteur trop puissant pour la canalisation peut la laisser chauffer trop longtemps en cas de surcharge. Mais le bon choix ne se résume pas à chercher une section dans un tableau : la charge, le câble et les conditions de pose doivent être examinés ensemble. Voici ce que le tableau 4.11 du RGIE Livre 1 V06 permet réellement de conclure et ce qu’un dimensionnement complet doit encore vérifier.",[12,19717,19719],{"id":19718},"lire-le-tableau-411-dans-lautre-sens","Lire le tableau 4.11 dans l’autre sens",[17,19721,19722,19723,19726],{},"Le tableau 4.11 de la sous-section 4.4.1.4 donne, pour les installations domestiques, le courant nominal maximal d’un coupe-circuit à fusible et d’un disjoncteur selon la section du conducteur. Le tableau ci-dessous est donc une ",[221,19724,19725],{},"limite légale indicative pour la section",", et non la garantie universelle qu’un câble de cette section est dimensionné dans toute situation.",[21,19728,19729,19741],{},[24,19730,19731],{},[27,19732,19733,19735,19738],{},[30,19734,13232],{},[30,19736,19737],{},"Plus petite section qui ressort du tableau 4.11",[30,19739,19740],{},"Exemple d’utilisation",[43,19742,19743,19753,19763,19773,19782,19791,19800,19809,19818],{},[27,19744,19745,19747,19750],{},[48,19746,3591],{},[48,19748,19749],{},"1,5 mm² pour un circuit domestique fixe ; 1 mm² figure au tableau mais pas dans le tableau 5.1 pour une canalisation fixe neuve",[48,19751,19752],{},"Éclairage sans prises",[27,19754,19755,19757,19760],{},[48,19756,3594],{},[48,19758,19759],{},"1,5 mm² selon le tableau 4.11, mais un circuit de prises exige au moins 2,5 mm² selon 5.2.1.2",[48,19761,19762],{},"Éclairage ou circuit sans prises",[27,19764,19765,19767,19770],{},[48,19766,3604],{},[48,19768,19769],{},"2,5 mm² comme plafond du tableau",[48,19771,19772],{},"Circuit terminal dédié, si les autres vérifications l’autorisent",[27,19774,19775,19777,19779],{},[48,19776,3614],{},[48,19778,3609],{},[48,19780,19781],{},"Circuit terminal de charge plus élevée",[27,19783,19784,19786,19788],{},[48,19785,3622],{},[48,19787,3619],{},[48,19789,19790],{},"Récepteur dédié plus puissant",[27,19792,19793,19795,19797],{},[48,19794,3625],{},[48,19796,3619],{},[48,19798,19799],{},"Alimentation ou circuit terminal lourd, après calcul complet",[27,19801,19802,19804,19806],{},[48,19803,3636],{},[48,19805,3630],{},[48,19807,19808],{},"Alimentation d’un tableau divisionnaire, après calcul complet",[27,19810,19811,19813,19815],{},[48,19812,3646],{},[48,19814,3641],{},[48,19816,19817],{},"Canalisation d’alimentation, après calcul complet",[27,19819,19820,19822,19824],{},[48,19821,3656],{},[48,19823,3651],{},[48,19825,19817],{},[17,19827,19828,19829,207,19832,19835],{},"Pour 2,5 mm², le tableau indique ",[221,19830,19831],{},"16 A comme maximum du fusible",[221,19833,19834],{},"20 A comme maximum du disjoncteur",". Cela ne rend pas automatiquement correct un disjoncteur de 20 A : pose, charge, chute de tension, court-circuit et type de canalisation restent à vérifier. Pour un circuit de prises, la section minimale de 5.2.1.2 reste applicable, même avec une protection plus faible.",[12,19837,19839],{"id":19838},"le-tableau-411-complet","Le tableau 4.11 complet",[21,19841,19842,19855],{},[24,19843,19844],{},[27,19845,19846,19848,19851,19853],{},[30,19847,3575],{},[30,19849,19850],{"align":8968},"Fusible max.",[30,19852,11433],{"align":8968},[30,19854,7522],{},[43,19856,19857,19871,19884,19896,19907,19918,19928,19938,19948,19958,19968],{},[27,19858,19859,19862,19865,19868],{},[48,19860,19861],{},"0,5 mm²",[48,19863,19864],{"align":8968},"2 A",[48,19866,19867],{"align":8968},"4 A",[48,19869,19870],{},"Circuits de commande, contrôle, signalisation et mesure uniquement",[27,19872,19873,19876,19878,19881],{},[48,19874,19875],{},"0,75 mm²",[48,19877,19867],{"align":8968},[48,19879,19880],{"align":8968},"6 A",[48,19882,19883],{},"Circuits intégrés dans les tableaux et ensembles de connexion",[27,19885,19886,19889,19891,19893],{},[48,19887,19888],{},"1 mm²",[48,19890,19880],{"align":8968},[48,19892,3591],{"align":8968},[48,19894,19895],{},"Pas d’exception neuve dans le tableau 5.1",[27,19897,19898,19900,19902,19904],{},[48,19899,3588],{},[48,19901,3591],{"align":8968},[48,19903,3594],{"align":8968},[48,19905,19906],{},"Circuits sans socles de prise de courant",[27,19908,19909,19911,19913,19915],{},[48,19910,3599],{},[48,19912,3594],{"align":8968},[48,19914,3604],{"align":8968},[48,19916,19917],{},"Catégorie générale du tableau",[27,19919,19920,19922,19924,19926],{},[48,19921,3609],{},[48,19923,3604],{"align":8968},[48,19925,3614],{"align":8968},[48,19927,19917],{},[27,19929,19930,19932,19934,19936],{},[48,19931,3619],{},[48,19933,3622],{"align":8968},[48,19935,3625],{"align":8968},[48,19937,19917],{},[27,19939,19940,19942,19944,19946],{},[48,19941,3630],{},[48,19943,3633],{"align":8968},[48,19945,3636],{"align":8968},[48,19947,19917],{},[27,19949,19950,19952,19954,19956],{},[48,19951,3641],{},[48,19953,3636],{"align":8968},[48,19955,3646],{"align":8968},[48,19957,19917],{},[27,19959,19960,19962,19964,19966],{},[48,19961,3651],{},[48,19963,3646],{"align":8968},[48,19965,3656],{"align":8968},[48,19967,19917],{},[27,19969,19970,19972,19974,19976],{},[48,19971,3661],{},[48,19973,3656],{"align":8968},[48,19975,3666],{"align":8968},[48,19977,19917],{},[17,19979,19980],{},"Les deux colonnes ne sont pas interchangeables. Remplacer un fusible de 16 A par un disjoncteur de 20 A sur 2,5 mm² augmente le courant nominal et demande une nouvelle vérification ; le tableau juxtapose seulement deux plafonds.",[12,19982,19984],{"id":19983},"pourquoi-le-tableau-ne-suffit-pas","Pourquoi le tableau ne suffit pas",[17,19986,19987,19988,19991,19992,19994,19995,19998],{},"Un dimensionnement correct commence par le courant de conception ",[221,19989,19990],{},"Ib",", attendu de la charge. On choisit ensuite le courant nominal ",[221,19993,18976],{}," et la capacité de transport ",[221,19996,19997],{},"Iz"," de la canalisation. Une vérification courante est Ib ≤ In ≤ Iz, avec les caractéristiques exigées de la protection. Iz ne dépend pas de la seule section.",[17,20000,20001],{},"Il faut notamment considérer :",[711,20003,20004,20007,20010,20013,20016,20019,20022],{},[714,20005,20006],{},"le matériau, l’isolation et la constitution du câble ou de la canalisation ;",[714,20008,20009],{},"le mode de pose (tube, isolation thermique, paroi, faisceau ou chemin de câbles) ;",[714,20011,20012],{},"le nombre de conducteurs chargés simultanément et les facteurs de groupement ;",[714,20014,20015],{},"la température ambiante, l’évacuation de la chaleur et les influences externes ;",[714,20017,20018],{},"la longueur, la charge et la chute de tension admissible ;",[714,20020,20021],{},"les conditions de coupure en cas de court-circuit et l’impédance de boucle de défaut ;",[714,20023,20024],{},"le pouvoir de coupure de la protection par rapport au courant de court-circuit présumé.",[17,20026,20027],{},"La protection doit donc être compatible avec la section et le circuit réel. Une longue liaison peut nécessiter une section supérieure pour la chute de tension ; une pose défavorable peut diminuer Iz. Un calibre acceptable reste inadéquat si l’impédance de boucle ne permet pas la coupure automatique ou si le pouvoir de coupure est insuffisant.",[12,20029,20031],{"id":20030},"tableau-51-les-exceptions-limitées-sous-25-mm","Tableau 5.1 : les exceptions limitées sous 2,5 mm²",[17,20033,20034],{},"La sous-section 5.2.1.2 interdit en principe les conducteurs isolés de moins de 2,5 mm² lorsqu’ils ne font pas partie intégrante d’une machine ou d’un appareil. Le tableau 5.1 énumère les exceptions :",[21,20036,20037,20047],{},[24,20038,20039],{},[27,20040,20041,20044],{},[30,20042,20043],{},"Minimum",[30,20045,20046],{},"Uniquement pour",[43,20048,20049,20056,20063],{},[27,20050,20051,20053],{},[48,20052,3588],{},[48,20054,20055],{},"Canalisations de circuits sans prises, sauf une prise individuelle d’au plus 2,5 A intégrée dans un luminaire",[27,20057,20058,20060],{},[48,20059,19875],{},[48,20061,20062],{},"Circuits intégrés dans les tableaux et ensembles de connexion alimentant un seul socle de prise ; la protection doit être adaptée à cette section",[27,20064,20065,20067],{},[48,20066,19861],{},[48,20068,20069],{},"Circuits de commande, contrôle, signalisation et mesure",[17,20071,20072],{},"La ligne 1 mm² du tableau 4.11 n’est donc pas, à elle seule, une autorisation de poser aujourd’hui une canalisation fixe de 1 mm² dans une habitation. Le tableau fixe la protection maximale lorsqu’une règle applicable permet cette section ; le tableau 5.1 en fixe ici le domaine d’emploi.",[12,20074,20076],{"id":20075},"câbles-emcb-et-emcvb-de-1-mm-dans-lexistant","Câbles EMCB et EMCVB de 1 mm² dans l’existant",[17,20078,20079,20080,20083,20084,20086],{},"Pour les parties existantes, les dérogations de la Partie 8 sont pertinentes. Pour les installations dont l’exécution sur place a commencé avant le ",[221,20081,20082],{},"17 mai 1986",", une canalisation EMCB ou EMCVB de ",[221,20085,19888],{}," peut rester en service, sous les conditions de la disposition dérogatoire, lorsqu’elle appartient à un circuit sans prises. Le dispositif de protection doit être adapté à la section. Il s’agit d’une tolérance pour une installation existante et non d’une règle permettant de poser du 1 mm² dans une installation neuve. L’état réel, la date et les documents disponibles doivent pouvoir être établis lors du contrôle.",[12,20088,20090],{"id":20089},"chute-de-tension-3-et-5-ne-sont-pas-une-limite-rgie","Chute de tension : 3 % et 5 % ne sont pas une limite RGIE",[17,20092,20093,20094,207,20096,20098],{},"Pour une vérification préalable, on utilise souvent ",[221,20095,8453],{},[221,20097,8456],{},". Ce sont des hypothèses utiles, pas des limites générales imposées par le RGIE 5.2.5, qui renvoie aux règles de l’art. Présentez-les comme un contrôle non contraignant : une longue liaison, un moteur, une borne de recharge ou un matériel sensible peut demander davantage après calcul.",[12,20100,20102],{"id":20101},"remplacer-un-ancien-fusible","Remplacer un ancien fusible",[17,20104,20105],{},"Sur un circuit existant, il faut d’abord identifier la canalisation réellement posée, son mode de pose, la charge attendue et les éventuelles dérogations liées à l’époque de construction. Les colonnes du tableau 4.11 viennent ensuite. Pour 2,5 mm², 16 A pour un fusible et 20 A pour un disjoncteur sont les plafonds du tableau ; ce ne sont pas des consignes d’augmenter la protection. Pour 1,5 mm², la limite du disjoncteur est 16 A, tandis qu’un circuit de prises reste soumis à la section minimale applicable.",[12,20107,20109],{"id":20108},"concevoir-et-documenter","Concevoir et documenter",[17,20111,6951,20112,20114,20115,20118],{},[203,20113,5823],{"href":1204},", vous pouvez saisir sections, protections, circuits et longueurs dans l’éditeur, exporter un PDF et lancer un ",[221,20116,20117],{},"auto-contrôle indicatif",". L’outil aide à organiser les données et les points ouverts. Il ne constitue ni un dimensionnement complet, ni une attestation de conformité RGIE, ni un remplacement des mesures ou du contrôle officiel.",[12,20120,1173],{"id":1172},[711,20122,20123,20128,20132],{},[714,20124,20125],{},[203,20126,20127],{"href":1574},"Calcul de chute de tension et choix de la section",[714,20129,20130],{},[203,20131,7847],{"href":6216},[714,20133,20134],{},[203,20135,20136],{"href":3283},"Créer un schéma unifilaire",{"title":1212,"searchDepth":1213,"depth":1213,"links":20138},[20139,20140,20141,20142,20143,20144,20145,20146,20147],{"id":19718,"depth":1213,"text":19719},{"id":19838,"depth":1213,"text":19839},{"id":19983,"depth":1213,"text":19984},{"id":20030,"depth":1213,"text":20031},{"id":20075,"depth":1213,"text":20076},{"id":20089,"depth":1213,"text":20090},{"id":20101,"depth":1213,"text":20102},{"id":20108,"depth":1213,"text":20109},{"id":1172,"depth":1213,"text":1173},"2026-03-18","Lisez correctement le tableau 4.11 du RGIE Livre 1 V06 : son plafond légal ne remplace pas le dimensionnement complet. Voyez aussi le tableau 5.1, les câbles EMCB et EMCVB anciens et la chute de tension.",{},"\u002Fblog\u002Fcable-cross-section-breaker.fr",{"title":19703,"description":20149},"section-cable-disjoncteur","blog\u002Fcable-cross-section-breaker.fr",[8830,10265,8832,20156],"installation-electrique","MBYBMaV5-RrnhLT9FlG908vEUWtprBLtqr26bXd1gKg",{"id":20159,"title":20160,"articleId":20161,"body":20162,"category":10248,"date":20408,"description":20409,"extension":1231,"lastUpdated":20410,"locale":1232,"meta":20411,"navigation":1234,"path":20412,"publishDate":20408,"readTime":19370,"refreshInterval":1237,"seo":20413,"slug":20414,"stem":20415,"tags":20416,"__hash__":20420},"blog\u002Fblog\u002Fxvb-vs-vob-cable.fr.md","Câble XVB vs. VOB : Lequel choisir pour votre installation ?","xvb-vs-vob-cable",{"type":9,"value":20163,"toc":20400},[20164,20168,20174,20178,20181,20185,20192,20196,20302,20304,20340,20344,20354,20373,20392,20394],[12928,20165,20167],{"id":20166},"câble-xvb-vs-vob-lequel-choisir","Câble XVB vs. VOB : Lequel choisir ?",[17,20169,20170,20173],{},[221,20171,20172],{},"Le XVB est le câble sous gaine standard pour les installations fixes dans les nouvelles constructions en Belgique."," Il contient plusieurs conducteurs avec une gaine extérieure et peut être posé directement dans les murs, les sols ou les conduits. Le VOB, en revanche, est un fil individuel qui doit toujours être placé dans un tube de protection ou une goulotte.",[12,20175,20177],{"id":20176},"quest-ce-que-le-xvb","Qu'est-ce que le XVB ?",[17,20179,20180],{},"Le XVB (p.ex. XVB 3G2,5) est un câble multiconducteur avec isolation PVC et gaine extérieure PVC. La désignation indique le nombre de conducteurs et la section. Le XVB est conçu pour une pose fixe — dans des saignées murales, sous enduit, dans des conduits ou sur des chemins de câbles.",[12,20182,20184],{"id":20183},"quest-ce-que-le-vob","Qu'est-ce que le VOB ?",[17,20186,20187,20188,20191],{},"Le VOB (p.ex. VOB 2,5mm²) est un fil souple individuel avec isolation PVC. Il ne peut ",[221,20189,20190],{},"jamais être posé librement"," et doit toujours être installé dans un tube de protection (conduit) ou une goulotte. Le VOB est moins cher au mètre, mais nécessite le coût supplémentaire du tube de protection.",[12,20193,20195],{"id":20194},"tableau-comparatif","Tableau comparatif",[21,20197,20198,20209],{},[24,20199,20200],{},[27,20201,20202,20204,20206],{},[30,20203,13257],{},[30,20205,18844],{},[30,20207,20208],{},"VOB",[43,20210,20211,20224,20237,20250,20263,20276,20289],{},[27,20212,20213,20218,20221],{},[48,20214,20215],{},[221,20216,20217],{},"Construction",[48,20219,20220],{},"Multiconducteur avec gaine",[48,20222,20223],{},"Fil individuel sans gaine",[27,20225,20226,20231,20234],{},[48,20227,20228],{},[221,20229,20230],{},"Pose",[48,20232,20233],{},"Directe dans mur, sol, conduit",[48,20235,20236],{},"Uniquement dans conduit\u002Fgoulotte",[27,20238,20239,20244,20247],{},[48,20240,20241],{},[221,20242,20243],{},"Tube requis ?",[48,20245,20246],{},"Non (optionnel)",[48,20248,20249],{},"Oui, toujours",[27,20251,20252,20257,20260],{},[48,20253,20254],{},[221,20255,20256],{},"Prix au mètre",[48,20258,20259],{},"Plus élevé (~1,50–3,00 €\u002Fm pour 3G2,5)",[48,20261,20262],{},"Plus bas (~0,30–0,50 €\u002Fm par conducteur)",[27,20264,20265,20270,20273],{},[48,20266,20267],{},[221,20268,20269],{},"Coût total",[48,20271,20272],{},"Souvent moins cher (pas de tube)",[48,20274,20275],{},"Tube + main-d'œuvre = plus cher",[27,20277,20278,20283,20286],{},[48,20279,20280],{},[221,20281,20282],{},"Flexibilité",[48,20284,20285],{},"Plus rigide, difficile à courber",[48,20287,20288],{},"Plus flexible dans le tube",[27,20290,20291,20296,20299],{},[48,20292,20293],{},[221,20294,20295],{},"Application typique",[48,20297,20298],{},"Neuf, rénovation",[48,20300,20301],{},"Rénovation dans conduits existants",[12,20303,19051],{"id":19050},[21,20305,20306,20314],{},[24,20307,20308],{},[27,20309,20310,20312],{},[30,20311,19060],{},[30,20313,19063],{},[43,20315,20316,20324],{},[27,20317,20318,20321],{},[48,20319,20320],{},"Art. 5.2.2",[48,20322,20323],{},"Les câbles doivent être adaptés au mode de pose ; les fils individuels (VOB) uniquement dans des tubes ou goulottes d'installation électrique",[27,20325,20326,20329],{},[48,20327,20328],{},"Art. 5.2.7.2 \u002F 5.2.7.3",[48,20330,20331,20332,18751,20334,20336,20337,20339],{},"Classe de réaction au feu CPR : câbles posés individuellement au minimum ",[221,20333,18750],{},[221,20335,18754],{}," au minimum ",[221,20338,18758],{}," (art. 5.2.7.3, art. 4.3.3.5b)",[12,20341,20343],{"id":20342},"recommandation","Recommandation",[17,20345,4201,20346,20349,20350,20353],{},[221,20347,20348],{},"nouvelles installations",", le XVB est le premier choix : moins d'étapes de travail, pas de tubes de protection nécessaires et conforme au RGIE. Le VOB convient surtout aux ",[221,20351,20352],{},"rénovations"," où des conduits existent déjà et où des fils individuels doivent être tirés.",[17,20355,20356,20357,20359,20360,20362,20363,7861,20366,20369,20370,20372],{},"Pour les deux types de câbles, veillez à la classe de réaction au feu CPR prescrite — en faisceaux, cloisons creuses et cavités constructives au minimum ",[221,20358,18758],{}," (art. 5.2.7.3), et pour les câbles posés individuellement dans les murs massifs sous enduit ",[221,20361,18750],{}," suffit (art. 5.2.7.2). La classification complémentaire à faible émission de fumée et faible acidité (",[221,20364,20365],{},"s1",[221,20367,20368],{},"a1",") est imposée par l'art. 4.3.3.7 a pour les lieux du tableau 4.10 : voies d'évacuation dans les bâtiments, locaux accessibles au public pouvant recevoir au moins 50 personnes et tunnels. À l'intérieur du logement, elle ne s'applique pas — le tableau 4.10 exclut expressément les installations domestiques. Attention toutefois en immeuble à appartements : les parties communes et locaux techniques d'un immeuble d'habitation ne sont ",[221,20371,1095],{}," des installations domestiques selon la partie 2 du RGIE, l'exigence vaut donc bien dans la cage d'escalier. Les câbles plus anciens sans classification CPR ne peuvent plus être utilisés dans les nouvelles installations.",[9883,20374,20375],{},[17,20376,20377,20380,20381,20384,20385,20388,20389,212],{},[221,20378,20379],{},"Code couleur (art. 5.1.6.2) :"," Le ",[221,20382,20383],{},"vert-jaune"," est réservé au conducteur de protection (PE\u002FPEN), le ",[221,20386,20387],{},"bleu"," au conducteur neutre (N) — ces deux couleurs sont interdites pour les conducteurs actifs (phases). Pour les conducteurs de phase (L1\u002FL2\u002FL3), on utilise donc habituellement le ",[221,20390,20391],{},"brun\u002Fnoir\u002Fgris",[12,20393,10024],{"id":10023},[17,20395,18818,20396,20399],{},[203,20397,5823],{"href":19355,"rel":20398},[5373],". L'auto-contrôle peut signaler certaines combinaisons de câble et de protection prises en charge, mais ne remplace pas un calcul professionnel.",{"title":1212,"searchDepth":1213,"depth":1213,"links":20401},[20402,20403,20404,20405,20406,20407],{"id":20176,"depth":1213,"text":20177},{"id":20183,"depth":1213,"text":20184},{"id":20194,"depth":1213,"text":20195},{"id":19050,"depth":1213,"text":19051},{"id":20342,"depth":1213,"text":20343},{"id":10023,"depth":1213,"text":10024},"2026-03-16","Comparaison entre le câble sous gaine XVB et le fil VOB pour les installations électriques belges selon le RGIE.","2026-08-18",{},"\u002Fblog\u002Fxvb-vs-vob-cable.fr",{"title":20160,"description":20409},"cable-xvb-vs-vob","blog\u002Fxvb-vs-vob-cable.fr",[20417,20418,20419,1133,8832],"câble","xvb","vob","ymobiuj7tzERW5y_4_XnGP97htqbyzdrfAcPhkICmaU",{"id":20422,"title":20423,"articleId":20424,"body":20425,"category":10248,"date":20658,"description":20659,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":20660,"navigation":1234,"path":20661,"publishDate":20658,"readTime":19370,"refreshInterval":1237,"seo":20662,"slug":20663,"stem":20664,"tags":20665,"__hash__":20673},"blog\u002Fblog\u002Finspection-checklist.fr.md","Que vérifie le contrôleur lors du contrôle électrique ?","inspection-checklist",{"type":9,"value":20426,"toc":20649},[20427,20431,20434,20438,20441,20465,20473,20477,20480,20530,20534,20537,20607,20610,20615,20617,20629,20634,20638,20641],[12,20428,20430],{"id":20429},"trois-domaines-documentation-contrôle-visuel-mesures","Trois domaines : documentation, contrôle visuel, mesures",[17,20432,20433],{},"Un organisme agréé examine les documents, l'installation visible et les essais ou mesures prévus. L'ordre et les conclusions relèvent de l'organisme ; les documents manquants sont appréciés selon les obligations applicables au dossier.",[12,20435,20437],{"id":20436},"_1-documentation","1. Documentation",[17,20439,20440],{},"Le contrôleur exige les documents suivants :",[711,20442,20443,20448,20453,20459],{},[714,20444,20445,20447],{},[221,20446,5869],{}," — présent, complet et à jour ?",[714,20449,20450,20452],{},[221,20451,6995],{}," — plan des pièces avec prises, interrupteurs et luminaires indiqués ?",[714,20454,20455,20458],{},[221,20456,20457],{},"Déclaration de conformité"," de l'installateur ?",[714,20460,20461,20464],{},[221,20462,20463],{},"Fiches techniques"," — tableau de distribution, différentiels, disjoncteurs ?",[9883,20466,20467],{},[17,20468,20469,20472],{},[221,20470,20471],{},"Préparez d'abord le dossier :"," un schéma absent ou dépassé peut donner lieu à une infraction. Cela ne permet pas de prédire l'ordre suivi par chaque organisme.",[12,20474,20476],{"id":20475},"_2-contrôle-visuel","2. Contrôle visuel",[17,20478,20479],{},"Ensuite, le contrôleur vérifie visuellement l'installation :",[711,20481,20482,20487,20493,20499,20505,20512,20519,20525],{},[714,20483,20484,20486],{},[221,20485,11427],{}," correcte par disjoncteur ? (ex. min. 2,5 mm² pour 16A pour circuits de prises ; pour l'éclairage 1,5 mm² pour 16A suffit)",[714,20488,20489,20492],{},[221,20490,20491],{},"Différentiel 30mA"," présent pour tous les circuits de prises ?",[714,20494,20495,20498],{},[221,20496,20497],{},"Zones de salle de bain"," respectées ? (Zone 0, 1, 2 selon RGIE Art. 7.1, définitions des zones Art. 7.1.3.2)",[714,20500,20501,20504],{},[221,20502,20503],{},"Raccordement de terre"," présent et accessible ?",[714,20506,20507,20508,20511],{},"Toutes les ",[221,20509,20510],{},"boîtes de dérivation"," fermées ?",[714,20513,20514,20515,20518],{},"Câbles correctement ",[221,20516,20517],{},"fixés"," et protégés ?",[714,20520,20521,20524],{},[221,20522,20523],{},"Interrupteur principal"," présent et librement accessible ?",[714,20526,20527,20529],{},[221,20528,12576],{}," présente ? (Art. 4.5.1 exige de manière générale la protection contre les surtensions selon les règles de l'art — en pratique, un SPD Type 2 est recommandé)",[12,20531,20533],{"id":20532},"_3-mesures","3. Mesures",[17,20535,20536],{},"Enfin, le contrôleur effectue des mesures techniques :",[21,20538,20539,20550],{},[24,20540,20541],{},[27,20542,20543,20545,20547],{},[30,20544,19537],{},[30,20546,3845],{},[30,20548,20549],{},"Instrument",[43,20551,20552,20563,20574,20585,20596],{},[27,20553,20554,20557,20560],{},[48,20555,20556],{},"Résistance de terre",[48,20558,20559],{},"\u003C 100 Ohm (Art. 4.2.4.3 a\u002Fb) ; au-delà de 30 Ohm, au moins deux différentiels à haute sensibilité requis",[48,20561,20562],{},"Telluromètre",[27,20564,20565,20568,20571],{},[48,20566,20567],{},"Résistance d'isolement",[48,20569,20570],{},"> 0,5 MOhm",[48,20572,20573],{},"Mégohmmètre (Megger)",[27,20575,20576,20579,20582],{},[48,20577,20578],{},"Impédance de boucle",[48,20580,20581],{},"Selon courant nominal MCB",[48,20583,20584],{},"Mesureur d'impédance de boucle",[27,20586,20587,20590,20593],{},[48,20588,20589],{},"Temps de déclenchement différentiel",[48,20591,20592],{},"\u003C 300 ms au courant différentiel nominal I∆n, \u003C 40 ms à 5× I∆n (selon IEC 61008)",[48,20594,20595],{},"Testeur de différentiel",[27,20597,20598,20601,20604],{},[48,20599,20600],{},"Mesure de tension",[48,20602,20603],{},"230V ±10%",[48,20605,20606],{},"Multimètre",[12,20608,9318],{"id":20609},"résultat",[17,20611,11843,20612,20614],{},[221,20613,11130],{},". Pour les nouvelles constructions et les rénovations importantes, le contrôle doit être réussi avant que le gestionnaire de réseau n'active le raccordement électrique. En cas de défauts, vous recevez un délai pour les corrections et devez planifier un nouveau contrôle.",[12,20616,10024],{"id":10023},[711,20618,20619,20624],{},[714,20620,20621],{},[203,20622,20623],{"href":6216},"Contrôle électrique en Belgique — ce qu'il faut savoir",[714,20625,20626],{},[203,20627,20628],{"href":4789},"Combien de prises par circuit ? (Limites RGIE)",[17,20630,20631],{},[203,20632,20633],{"href":7861},"Créez votre schéma unifilaire conforme RGIE — gratuit →",[12,20635,20637],{"id":20636},"préparer-un-dossier-vérifiable","Préparer un dossier vérifiable",[17,20639,20640],{},"Avant le rendez-vous, confrontez le schéma unifilaire et le plan de position à l'installation réelle. Reprenez les mêmes lettres de circuits et numéros de points, étiquetez le tableau, laissez les capots accessibles et rassemblez les anciens rapports ainsi que les notices qui appartiennent au dossier. N'ouvrez jamais une partie sous tension pour préparer la visite.",[17,20642,20643,20644,20648],{},"La référence est la ",[203,20645,20647],{"href":6185,"rel":20646},[5373],"page du SPF Économie sur le contrôle des installations domestiques",". Le rapport de l'organisme, et non cette liste ni l'autocontrôle indicatif de PlanElec, fixe les constatations et l'éventuel délai de suivi.",{"title":1212,"searchDepth":1213,"depth":1213,"links":20650},[20651,20652,20653,20654,20655,20656,20657],{"id":20429,"depth":1213,"text":20430},{"id":20436,"depth":1213,"text":20437},{"id":20475,"depth":1213,"text":20476},{"id":20532,"depth":1213,"text":20533},{"id":20609,"depth":1213,"text":9318},{"id":10023,"depth":1213,"text":10024},{"id":20636,"depth":1213,"text":20637},"2026-03-13","Documentation, contrôle visuel, mesures — découvrez point par point ce que le contrôleur vérifie et mesure réellement lors d'un contrôle électrique en Belgique.",{},"\u002Fblog\u002Finspection-checklist.fr",{"title":20423,"description":20659},"checklist-controle","blog\u002Finspection-checklist.fr",[1243,1242,14141,6255,1248,20666,8422,20667,20668,20669,20670,1249,20671,20672],"eendraadschema","Situationsplan","différentiel","résistance de terre","résistance d'isolement","Eindrahtschema","single-line diagram","vi2njD105w-Yr7bN1KiwFfzZxFy_P-1y0be9HrCEzxM",{"id":20675,"title":20628,"articleId":20676,"body":20677,"category":10248,"date":20860,"description":20861,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":20862,"navigation":1234,"path":20863,"publishDate":20860,"readTime":10253,"refreshInterval":1237,"seo":20864,"slug":20865,"stem":20866,"tags":20867,"__hash__":20869},"blog\u002Fblog\u002Fsockets-per-circuit.fr.md","sockets-per-circuit",{"type":9,"value":20678,"toc":20851},[20679,20683,20697,20701,20748,20752,20807,20811,20814,20818,20824,20826,20836,20840,20844],[12,20680,20682],{"id":20681},"maximum-8-prises-par-circuit","Maximum 8 prises par circuit",[17,20684,20685,20686,20689,20690,20692,20693,20696],{},"Le RGIE stipule à l'",[221,20687,20688],{},"Art. 5.3.5.2b"," : un maximum de ",[221,20691,16818],{}," peut être installé par circuit terminal. Cette limite de huit points s'applique exclusivement aux prises, pas aux points lumineux. Une règle de comptage importante s'applique — une prise double compte comme ",[221,20694,20695],{},"un"," seul point, pas deux.",[12,20698,20700],{"id":20699},"règles-de-comptage-en-détail","Règles de comptage en détail",[21,20702,20703,20712],{},[24,20704,20705],{},[27,20706,20707,20709],{},[30,20708,8965],{},[30,20710,20711],{},"Compte comme",[43,20713,20714,20721,20727,20734,20741],{},[27,20715,20716,20718],{},[48,20717,17924],{},[48,20719,20720],{},"1 point",[27,20722,20723,20725],{},[48,20724,17939],{},[48,20726,20720],{},[27,20728,20729,20732],{},[48,20730,20731],{},"Prise triple",[48,20733,20720],{},[27,20735,20736,20739],{},[48,20737,20738],{},"Point lumineux",[48,20740,20720],{},[27,20742,20743,20746],{},[48,20744,20745],{},"Raccordement fixe (four, taque)",[48,20747,13215],{},[12,20749,20751],{"id":20750},"câble-et-disjoncteur-par-type-de-circuit","Câble et disjoncteur par type de circuit",[21,20753,20754,20768],{},[24,20755,20756],{},[27,20757,20758,20761,20763,20765],{},[30,20759,20760],{},"Type de circuit",[30,20762,1059],{},[30,20764,13232],{},[30,20766,20767],{},"Max. points",[43,20769,20770,20781,20794],{},[27,20771,20772,20774,20776,20779],{},[48,20773,5134],{},[48,20775,6008],{},[48,20777,20778],{},"16A ou 20A",[48,20780,17125],{},[27,20782,20783,20785,20788,20791],{},[48,20784,16685],{},[48,20786,20787],{},"XVB 3G1,5",[48,20789,20790],{},"10A ou 16A",[48,20792,20793],{},"aucun maximum fixe (min. 2 circuits éclairage si >2 pièces)",[27,20795,20796,20799,20802,20805],{},[48,20797,20798],{},"Dédié (four)",[48,20800,20801],{},"XVB 3G4 ou 3G6",[48,20803,20804],{},"20A ou 32A",[48,20806,4482],{},[12,20808,20810],{"id":20809},"scénario-de-planification-modifiable","Scénario de planification modifiable",[17,20812,20813],{},"Pour une maison de trois chambres avec cuisine, salle de bains et séjour, commencez par grouper les points par usage. Le nombre réel découle des points comptés, circuits exclusifs, répartition spatiale et disponibilité souhaitée. Les anciennes fourchettes de cet article n'étaient pas une statistique officielle et ne sont donc plus présentées comme exigence typique.",[12,20815,20817],{"id":20816},"installations-existantes-rgie-partie-8","Installations existantes (RGIE Partie 8)",[17,20819,20820,20821,20823],{},"Pour les installations existantes construites avant le RGIE actuel, la ",[221,20822,15590],{}," autorise plus de 8 prises par circuit sous certaines conditions — à condition que la puissance des appareils raccordés n'excède pas la puissance admise pour la canalisation et que la section du câble soit suffisamment dimensionnée. Toutefois, en cas de rénovation ou d'extension, les limites actuelles s'appliquent.",[12,20825,10024],{"id":10023},[711,20827,20828,20832],{},[714,20829,20830],{},[203,20831,10209],{"href":10208},[714,20833,20834],{},[203,20835,20623],{"href":6216},[17,20837,20838],{},[203,20839,20633],{"href":7861},[12,20841,20843],{"id":20842},"compter-avant-de-documenter","Compter avant de documenter",[17,20845,20846,20847,212],{},"Comptez les points de raccordement, non les cadres. Sur un circuit mixte, la sous-section 5.3.5.2 assimile un appareil fixe, ou un groupe commandé ensemble, à une prise. Vérifiez aussi si la sous-section 5.2.1.2 impose un circuit exclusif. Reprenez les mêmes numéros sur les deux plans. Source : ",[203,20848,20850],{"href":5371,"rel":20849},[5373],"Livre 1 V06",{"title":1212,"searchDepth":1213,"depth":1213,"links":20852},[20853,20854,20855,20856,20857,20858,20859],{"id":20681,"depth":1213,"text":20682},{"id":20699,"depth":1213,"text":20700},{"id":20750,"depth":1213,"text":20751},{"id":20809,"depth":1213,"text":20810},{"id":20816,"depth":1213,"text":20817},{"id":10023,"depth":1213,"text":10024},{"id":20842,"depth":1213,"text":20843},"2026-03-11","Maximum 8 points par circuit — mais comment compter correctement ? Découvrez les règles du RGIE pour les prises, l'éclairage et les circuits dédiés.",{},"\u002Fblog\u002Fsockets-per-circuit.fr",{"title":20628,"description":20861},"prises-par-circuit","blog\u002Fsockets-per-circuit.fr",[1243,1242,20868,7391,10265,20417,18844,1248,20666,10095,12444,1249,20671,8422],"prise","lWNx4zr5eIPBpxs39qVpB4su4meS9deeIxgLPl-pNbA",{"id":20871,"title":20872,"articleId":20873,"body":20874,"category":10248,"date":21240,"description":21241,"extension":1231,"lastUpdated":13185,"locale":1232,"meta":21242,"navigation":1234,"path":21243,"publishDate":21240,"readTime":19370,"refreshInterval":1237,"seo":21244,"slug":21245,"stem":21246,"tags":21247,"__hash__":21252},"blog\u002Fblog\u002Fbathroom-cables-arei-zones.fr.md","Quels câbles utiliser dans la salle de bain ? (Zones RGIE)","bathroom-cables-arei-zones",{"type":9,"value":20875,"toc":21229},[20876,20880,20890,20894,20901,20960,20971,20974,20978,21085,21089,21118,21122,21183,21187,21194,21205,21209,21212,21214,21224],[12,20877,20879],{"id":20878},"le-xvb-est-toujours-autorisé-le-vob-sous-conditions","Le XVB est toujours autorisé — le VOB sous conditions",[17,20881,20882,20883,20885,20886,20889],{},"L'installation électrique dans la salle de bain est soumise à des règles particulières en Belgique. La règle de base : le ",[221,20884,13540],{}," (câble sous gaine) est autorisé dans toutes les zones de la salle de bain en dehors de la zone 0. Le ",[221,20887,20888],{},"fil VOB en conduit"," (Preflex) est soumis à des restrictions — notamment dans les cloisons creuses.",[12,20891,20893],{"id":20892},"les-zones-rgie-de-la-salle-de-bain","Les zones RGIE de la salle de bain",[17,20895,20896,20897,20900],{},"Le RGIE définit ",[221,20898,20899],{},"trois zones"," autour de la baignoire et de la douche : zone 0, zone 1, zone 2 (uniquement pour les baignoires) et la zone hors périmètre (art. 7.1.3.2).",[21,20902,20903,20916],{},[24,20904,20905],{},[27,20906,20907,20910,20913],{},[30,20908,20909],{},"Zone",[30,20911,20912],{},"Périmètre",[30,20914,20915],{},"Installation autorisée",[43,20917,20918,20931,20944],{},[27,20919,20920,20925,20928],{},[48,20921,20922],{},[221,20923,20924],{},"Zone 0",[48,20926,20927],{},"Intérieur de la baignoire\u002Fdouche",[48,20929,20930],{},"TBTS ≤ 12V uniquement, IPX7",[27,20932,20933,20938,20941],{},[48,20934,20935],{},[221,20936,20937],{},"Zone 1",[48,20939,20940],{},"Verticalement au-dessus de la zone 0, jusqu'à 2,25 m de hauteur",[48,20942,20943],{},"Appareils fixes ≥ IPX4 ; prises TBTS et interrupteurs TBTS autorisés (art. 7.1.5.2c n° 2 et 4)",[27,20945,20946,20951,20957],{},[48,20947,20948],{},[221,20949,20950],{},"Zone 2",[48,20952,20953,20954],{},"60 cm autour de la zone 1 — ",[221,20955,20956],{},"uniquement pour les baignoires",[48,20958,20959],{},"Prises uniquement avec différentiel à très haute sensibilité (≤ 10 mA) ou transformateur de séparation de 100 W (art. 7.1.5.2d n° 2) ; appareils ≥ IPX4",[9883,20961,20962],{},[17,20963,20964,20966,20967,20970],{},[221,20965,13530],{}," La zone 2 n'est ",[221,20968,20969],{},"pas définie"," pour les douches (art. 7.1.3.2 n° 3b). Pour les douches, la zone 1 est directement suivie de la zone hors périmètre.",[17,20972,20973],{},"En dehors de ces zones, les règles d'installation normales s'appliquent.",[12,20975,20977],{"id":20976},"types-de-câbles-et-leur-admissibilité","Types de câbles et leur admissibilité",[21,20979,20980,20997],{},[24,20981,20982],{},[27,20983,20984,20986,20988,20990,20992,20994],{},[30,20985,13469],{},[30,20987,18619],{},[30,20989,20924],{},[30,20991,20937],{},[30,20993,20950],{},[30,20995,20996],{},"Hors zones",[43,20998,20999,21015,21032,21049,21068],{},[27,21000,21001,21005,21007,21009,21011,21013],{},[48,21002,21003],{},[221,21004,6008],{},[48,21006,18758],{},[48,21008,12375],{},[48,21010,8064],{},[48,21012,8064],{},[48,21014,8064],{},[27,21016,21017,21021,21023,21025,21028,21030],{},[48,21018,21019],{},[221,21020,20787],{},[48,21022,18758],{},[48,21024,12375],{},[48,21026,21027],{},"Oui (éclairage)",[48,21029,8064],{},[48,21031,8064],{},[27,21033,21034,21039,21041,21043,21045,21047],{},[48,21035,21036],{},[221,21037,21038],{},"VOB en Preflex gris",[48,21040,3402],{},[48,21042,12375],{},[48,21044,8064],{},[48,21046,8064],{},[48,21048,8064],{},[27,21050,21051,21056,21058,21060,21063,21066],{},[48,21052,21053],{},[221,21054,21055],{},"VOB en Preflex vert",[48,21057,3402],{},[48,21059,12375],{},[48,21061,21062],{},"Non (cloison creuse)",[48,21064,21065],{},"Restreint",[48,21067,8064],{},[27,21069,21070,21075,21077,21079,21081,21083],{},[48,21071,21072],{},[221,21073,21074],{},"H07Z1-U (sans halogène)",[48,21076,18758],{},[48,21078,12375],{},[48,21080,8064],{},[48,21082,8064],{},[48,21084,8064],{},[5686,21086,21088],{"id":21087},"notes-importantes-sur-les-types-de-câbles","Notes importantes sur les types de câbles",[711,21090,21091,21096,21106,21112],{},[714,21092,21093,21095],{},[221,21094,18844],{}," (câble sous gaine) : Toujours le choix sûr. Adapté pour l'encastrement, le montage en saillie et les chemins de câbles.",[714,21097,21098,21101,21102,21105],{},[221,21099,21100],{},"Preflex gris"," (conduit standard avec VOB pré-tiré) : Autorisé dans les murs massifs. ",[221,21103,21104],{},"Interdit"," dans les cloisons creuses et faux plafonds.",[714,21107,21108,21111],{},[221,21109,21110],{},"Preflex Safe (vert)"," : Dans les murs massifs, le Preflex Safe (Cca) est autorisé même en zone 1. La restriction concerne les cloisons creuses (construction sèche), pas la zone elle-même.",[714,21113,21114,21117],{},[221,21115,21116],{},"H07Z1-U"," : Fil sans halogène, particulièrement recommandé pour les zones sensibles. Note : le H07Z1-U en tant que fil individuel n'a pas de classe CPR Cca inhérente — la classe se réfère au système de câblage (fil + conduit). Le H07Z1-U en Preflex Safe atteint Cca.",[12,21119,21121],{"id":21120},"tableau-des-sections","Tableau des sections",[21,21123,21124,21135],{},[24,21125,21126],{},[27,21127,21128,21130,21133],{},[30,21129,17910],{},[30,21131,21132],{},"Section min.",[30,21134,13232],{},[43,21136,21137,21145,21153,21163,21172],{},[27,21138,21139,21141,21143],{},[48,21140,16685],{},[48,21142,3588],{},[48,21144,20790],{},[27,21146,21147,21149,21151],{},[48,21148,5134],{},[48,21150,3599],{},[48,21152,20778],{},[27,21154,21155,21158,21160],{},[48,21156,21157],{},"Lave-linge \u002F sèche-linge",[48,21159,3599],{},[48,21161,21162],{},"16A (circuit dédié)",[27,21164,21165,21168,21170],{},[48,21166,21167],{},"Chauffe-eau électrique (sous évier, ≤ 2 kW)",[48,21169,3599],{},[48,21171,11446],{},[27,21173,21174,21177,21180],{},[48,21175,21176],{},"Chauffe-eau instantané (18–27 kW)",[48,21178,21179],{},"6 mm² (32A) ou 10 mm² (40A, triphasé)",[48,21181,21182],{},"32A ou 40A",[12,21184,21186],{"id":21185},"la-protection-différentielle-30ma-est-obligatoire","La protection différentielle 30mA est obligatoire",[17,21188,21189,21190,21193],{},"Selon l'article 7.1.4.3 du RGIE, ",[221,21191,21192],{},"tous les circuits de la salle de bain"," doivent être protégés par un différentiel à haute ou très haute sensibilité (typiquement 30 mA) — à l'exception des circuits TBTS, des circuits à séparation électrique et des installations de sécurité. Cela s'applique aussi bien à l'éclairage qu'aux prises et aux appareils fixes.",[9883,21195,21196],{},[17,21197,21198,21200,21201,21204],{},[221,21199,9889],{}," : Même les circuits qui ne font que ",[60,21202,21203],{},"traverser"," la salle de bain (par exemple, des câbles vers les combles) doivent respecter les exigences des zones s'ils passent à l'intérieur des zones de protection.",[12,21206,21208],{"id":21207},"liaison-équipotentielle-dans-la-salle-de-bain","Liaison équipotentielle dans la salle de bain",[17,21210,21211],{},"Important : le RGIE (art. 7.1.4.4) exige une liaison équipotentielle supplémentaire dans la salle de bain — toutes les parties métalliques simultanément accessibles (conduites d'eau, radiateurs, baignoire, tuyaux d'évacuation) doivent être reliées localement entre elles et aux conducteurs de protection des circuits de la salle de bain. L'absence de liaison équipotentielle est un motif fréquent de non-conformité lors du contrôle.",[12,21213,10024],{"id":10023},[711,21215,21216,21220],{},[714,21217,21218],{},[203,21219,10209],{"href":10208},[714,21221,21222],{},[203,21223,20623],{"href":6216},[17,21225,21226],{},[203,21227,21228],{"href":7861},"Planifiez l'électricité de votre salle de bain avec PlanElec — gratuit →",{"title":1212,"searchDepth":1213,"depth":1213,"links":21230},[21231,21232,21233,21236,21237,21238,21239],{"id":20878,"depth":1213,"text":20879},{"id":20892,"depth":1213,"text":20893},{"id":20976,"depth":1213,"text":20977,"children":21234},[21235],{"id":21087,"depth":5848,"text":21088},{"id":21120,"depth":1213,"text":21121},{"id":21185,"depth":1213,"text":21186},{"id":21207,"depth":1213,"text":21208},{"id":10023,"depth":1213,"text":10024},"2026-03-09","Le XVB est toujours autorisé, le VOB en conduit seulement sous conditions. Découvrez quels types de câbles sont autorisés dans chaque zone RGIE.",{},"\u002Fblog\u002Fbathroom-cables-arei-zones.fr",{"title":20872,"description":21241},"cables-salle-de-bain-rgie","blog\u002Fbathroom-cables-arei-zones.fr",[1243,1242,15823,21248,18844,20208,21249,2785,20668,21250,10095,12444,1249,1248,20666,8422,21251],"zones","Preflex","30mA","CPR","hc3YRUsC3jb5q4ZpZfM02fE4vg-csXF6E99UgpOx1OM",{"id":21254,"title":8371,"articleId":21255,"body":21256,"category":10248,"date":21488,"description":21489,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":21490,"navigation":1234,"path":21491,"publishDate":21488,"readTime":10253,"refreshInterval":1237,"seo":21492,"slug":21493,"stem":21494,"tags":21495,"__hash__":21498},"blog\u002Fblog\u002Fwhat-is-a-situation-plan.fr.md","what-is-a-situation-plan",{"type":9,"value":21257,"toc":21479},[21258,21262,21275,21281,21283,21295,21334,21337,21341,21345,21374,21378,21457,21460,21462,21474],[12,21259,21261],{"id":21260},"un-plan-au-sol-de-votre-installation-électrique","Un plan au sol de votre installation électrique",[17,21263,21264,21265,21268,21269,21271,21272,21274],{},"Le plan de situation (néerlandais : ",[60,21266,21267],{},"situatieschema",", allemand : ",[60,21270,20667],{},") est un plan simplifié du bâtiment montrant la ",[221,21273,17729],{}," du matériel électrique pertinent — prises, interrupteurs, luminaires, tableaux et appareils fixes. Aucune échelle universelle n'est imposée ; la lisibilité et l'absence d'ambiguïté sont essentielles.",[17,21276,21277,21278,21280],{},"Contrairement au schéma unifilaire, le plan de situation ne montre pas la hiérarchie logique des circuits, mais ",[221,21279,17713],{}," tout se trouve.",[12,21282,18740],{"id":18739},[17,21284,1759,21285,21289,21290,21294],{},[203,21286,21288],{"href":6185,"rel":21287},[5373],"page officielle du SPF Economie sur le contrôle domestique"," cite le schéma unifilaire et le plan de situation parmi les documents à remettre au minimum. Le ",[203,21291,21293],{"href":13789,"rel":21292},[5373],"Livre 1 du RGIE en vigueur"," précise leur contenu et leurs repères communs :",[21,21296,21297,21308],{},[24,21298,21299],{},[27,21300,21301,21303,21305],{},[30,21302,2589],{},[30,21304,19060],{},[30,21306,21307],{},"Montre",[43,21309,21310,21322],{},[27,21311,21312,21316,21319],{},[48,21313,21314],{},[221,21315,5869],{},[48,21317,21318],{},"Art. 9.1.2 Nr. 1",[48,21320,21321],{},"Structure logique — dispositifs de protection, circuits, hiérarchie",[27,21323,21324,21328,21331],{},[48,21325,21326],{},[221,21327,6995],{},[48,21329,21330],{},"Art. 9.1.2 Nr. 2",[48,21332,21333],{},"Position physique — où tout est installé dans le bâtiment, y compris l'emplacement du compteur et du système de mise à la terre",[17,21335,21336],{},"Les documents doivent correspondre à l'installation réelle. Des plans absents ou contradictoires peuvent être repris comme infraction ; seul l'organisme agréé établit la conclusion officielle.",[12,21338,21340],{"id":21339},"que-doit-contenir-le-plan-de-situation","Que doit contenir le plan de situation ?",[5686,21342,21344],{"id":21343},"liste-de-vérification","Liste de vérification",[711,21346,21347,21350,21353,21356,21359,21362,21365,21368,21371],{},[714,21348,21349],{},"Plan simplifié et lisible de chaque étage concerné",[714,21351,21352],{},"Position de toutes les prises (simple, double, avec terre)",[714,21354,21355],{},"Position de tous les interrupteurs (on\u002Foff, va-et-vient, variateur)",[714,21357,21358],{},"Points lumineux (plafond, mur, extérieur)",[714,21360,21361],{},"Tableau de distribution et emplacement du compteur",[714,21363,21364],{},"Appareils fixes (plaque de cuisson, chauffe-eau, borne de recharge)",[714,21366,21367],{},"Emplacement non ambigu du matériel référencé au schéma unifilaire",[714,21369,21370],{},"Numéros de référence des circuits (doivent correspondre au schéma unifilaire)",[714,21372,21373],{},"Symboles appropriés du tableau 2.23 du RGIE (chapitre 2.13)",[12,21375,21377],{"id":21376},"plan-de-situation-vs-schéma-unifilaire","Plan de situation vs. schéma unifilaire",[21,21379,21380,21391],{},[24,21381,21382],{},[27,21383,21384,21387,21389],{},[30,21385,21386],{},"Propriété",[30,21388,6995],{},[30,21390,5869],{},[43,21392,21393,21404,21414,21424,21435,21446],{},[27,21394,21395,21398,21401],{},[48,21396,21397],{},"Représentation",[48,21399,21400],{},"Plan au sol physique",[48,21402,21403],{},"Schéma logique des circuits",[27,21405,21406,21409,21412],{},[48,21407,21408],{},"Montre la position ?",[48,21410,21411],{},"Oui — emplacement exact",[48,21413,12375],{},[27,21415,21416,21419,21421],{},[48,21417,21418],{},"Montre la hiérarchie ?",[48,21420,12375],{},[48,21422,21423],{},"Oui — du réseau au consommateur",[27,21425,21426,21429,21432],{},[48,21427,21428],{},"Dispositifs de protection",[48,21430,21431],{},"Position uniquement",[48,21433,21434],{},"Calibres, type, coordination",[27,21436,21437,21440,21443],{},[48,21438,21439],{},"Info câbles",[48,21441,21442],{},"Chemins visibles",[48,21444,21445],{},"Type et section indiqués",[27,21447,21448,21451,21454],{},[48,21449,21450],{},"À l'échelle",[48,21452,21453],{},"Pas d'échelle universelle ; lisible et sans ambiguïté",[48,21455,21456],{},"Non coté à l'échelle",[17,21458,21459],{},"Les deux documents se complètent et sont également obligatoires.",[12,21461,10024],{"id":10023},[711,21463,21464,21469],{},[714,21465,21466],{},[203,21467,21468],{"href":3283},"Créer un schéma unifilaire — étape par étape",[714,21470,21471],{},[203,21472,21473],{"href":205},"Combien coûte un plan électrique en Belgique ?",[17,21475,21476],{},[203,21477,21478],{"href":7861},"Créez votre plan de situation avec PlanElec — gratuit →",{"title":1212,"searchDepth":1213,"depth":1213,"links":21480},[21481,21482,21483,21486,21487],{"id":21260,"depth":1213,"text":21261},{"id":18739,"depth":1213,"text":18740},{"id":21339,"depth":1213,"text":21340,"children":21484},[21485],{"id":21343,"depth":5848,"text":21344},{"id":21376,"depth":1213,"text":21377},{"id":10023,"depth":1213,"text":10024},"2026-03-06","Le plan de situation montre où tous les composants électriques sont physiquement installés dans votre bâtiment. Découvrez ce qu'il doit contenir et comment il se distingue du schéma unifilaire.",{},"\u002Fblog\u002Fwhat-is-a-situation-plan.fr",{"title":8371,"description":21489},"plan-de-situation","blog\u002Fwhat-is-a-situation-plan.fr",[1243,1242,8422,21267,20667,21496,1248,20666,20671,10095,21497,1249],"situation plan","plan au sol","C0nI_Vt_a9zOgViA9ATEI6ri8t5FF9JKFGPnVfaTAEc",{"id":21500,"title":21501,"articleId":21502,"body":21503,"category":10248,"date":21690,"description":21691,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":21692,"navigation":1234,"path":21693,"publishDate":21690,"readTime":7919,"refreshInterval":1237,"seo":21694,"slug":21695,"stem":21696,"tags":21697,"__hash__":21699},"blog\u002Fblog\u002F30ma-rcd-per-socket.fr.md","Un différentiel 30 mA par prise ? Ce que dit le RGIE Livre 1 V06 (2026)","30ma-rcd-per-socket",{"type":9,"value":21504,"toc":21679},[21505,21509,21512,21515,21519,21526,21571,21578,21581,21585,21592,21595,21598,21602,21609,21616,21619,21623,21626,21629,21633,21640,21643,21647,21650,21654,21662,21664],[12,21506,21508],{"id":21507},"réponse-courte-ni-par-prise-ni-par-circuit","Réponse courte : ni par prise, ni par circuit",[17,21510,21511],{},"Non. Pour une installation domestique neuve, le RGIE ne demande pas un différentiel de 30 mA pour chaque prise individuelle. Il ne demande pas non plus un différentiel séparé pour chaque circuit de prises. L’exigence porte sur la protection des circuits concernés : un seul dispositif de protection à courant différentiel-résiduel (DDR) à haute ou très haute sensibilité peut protéger plusieurs circuits terminaux. Dans l’exécution habituelle, son courant différentiel de fonctionnement est au maximum de 30 mA.",[17,21513,21514],{},"Le choix dépend de la nature des circuits, de la protection à l’origine et de la prise de terre. Une multiprise ne change rien au circuit auquel elle est raccordée.",[12,21516,21518],{"id":21517},"rgie-livre-1-v06-la-règle-pour-une-installation-neuve","RGIE Livre 1 V06 : la règle pour une installation neuve",[17,21520,21521,21522,21525],{},"Cette explication a été vérifiée dans le ",[221,21523,21524],{},"RGIE Livre 1 V06 officiel"," disponible localement. Pour les installations domestiques, la règle principale se trouve à la sous-section 4.2.4.3, point b. À l’origine de l’installation, au moins un DDR dont le courant différentiel de fonctionnement ne dépasse pas 300 mA est installé. Immédiatement en aval, au moins un DDR à haute ou très haute sensibilité (maximum 30 mA) protège au minimum les groupes suivants :",[21,21527,21528,21538],{},[24,21529,21530],{},[27,21531,21532,21535],{},[30,21533,21534],{},"Circuit ou local",[30,21536,21537],{},"Sens de la règle",[43,21539,21540,21548,21555,21563],{},[27,21541,21542,21545],{},[48,21543,21544],{},"Prises qui ne servent pas des appareils fixes",[48,21546,21547],{},"Les circuits ordinaires de prises passent derrière le DDR sensible.",[27,21549,21550,21552],{},[48,21551,16685],{},[48,21553,21554],{},"Les circuits d’éclairage sont également repris pour une installation domestique neuve.",[27,21556,21557,21560],{},[48,21558,21559],{},"Locaux avec baignoire et\u002Fou douche",[48,21561,21562],{},"Les circuits qui alimentent ces locaux sont concernés.",[27,21564,21565,21568],{},[48,21566,21567],{},"Lave-linge, sèche-linge et lave-vaisselle",[48,21569,21570],{},"Ces appareils sont expressément cités.",[17,21572,21573,21574,21577],{},"Un tel différentiel ne peut reprendre que ",[221,21575,21576],{},"huit circuits terminaux au maximum",". Cette limite concerne les circuits en aval, non les prises. Une maison ayant six circuits appropriés peut donc avoir un seul différentiel 30 mA ; en répartir trois sur chacun de deux différentiels est aussi possible. Cette répartition limite l’étendue d’une coupure, mais le RGIE n’impose pas un DDR séparé par circuit.",[17,21579,21580],{},"Les appareils fixes ou à poste fixe, comme un réfrigérateur, une cuisinière ou un chauffage électrique, peuvent être raccordés à un DDR supplémentaire à l’origine selon l’exception prévue. Ce n’est pas une permission de placer prises ou éclairage derrière 300 mA : lave-linge, sèche-linge et lave-vaisselle sont dans la liste 30 mA.",[12,21582,21584],{"id":21583},"huit-prises-par-circuit-terminal","Huit prises par circuit terminal",[17,21586,21587,21588,21591],{},"La sous-section 5.3.5.2, point b, limite à huit le nombre de ",[221,21589,21590],{},"socles de prise de courant simples ou multiples"," par circuit terminal. Cette règle concerne donc le circuit terminal lui-même, et non l’ajout d’un différentiel par prise.",[17,21593,21594],{},"Un socle multiple est le bloc fixe installé dans ou sur le mur avec, par exemple, deux ou trois possibilités de raccordement. Une prise double compte comme un socle multiple, donc comme un seul point au sens de cette règle, et ne justifie pas un différentiel supplémentaire. Une multiprise ou un enrouleur portable n’est pas un moyen de contourner la limite : il est branché sur un socle existant et ne crée ni circuit ni protection nouvelle.",[17,21596,21597],{},"Prises, luminaires et appareils fixes peuvent parfois partager un circuit terminal. Un appareil fixe, ou un groupe commandé par un appareil commun, est alors assimilé à un socle. Les appareils qui exigent leur propre circuit selon 5.2.1.2 restent exclus. Cela ne compte pas toutes les fiches utilisées.",[12,21599,21601],{"id":21600},"résistance-de-dispersion-supérieure-à-30-ohms","Résistance de dispersion supérieure à 30 ohms",[17,21603,21604,21605,21608],{},"Le seuil de 30 ohms n’est pas une alternative à la protection 30 mA. Lorsque la résistance de dispersion de la prise de terre est ",[221,21606,21607],{},"supérieure à 30 ohms",", le Livre 1 V06 exige au moins deux DDR à haute ou très haute sensibilité pour les circuits visés. Chaque DDR peut reprendre au maximum seize socles de prise de courant simples ou multiples. Un appareil fixe, ou un groupe d’appareils fixes commandé par un appareil commun, peut être assimilé à un socle pour ce décompte.",[17,21610,21611,21612,21615],{},"Une mesure complémentaire est alors nécessaire. Pour les circuits de l’exception concernant les appareils fixes, les transformateurs de séparation individuels et les autres circuits qui ne figurent pas dans la liste des circuits 30 mA, les DDR placés à l’origine de l’installation doivent aussi être complétés par au moins un DDR dont le courant différentiel de fonctionnement ne dépasse pas ",[221,21613,21614],{},"100 mA par circuit ou groupe de circuits",". Ce 100 mA est une protection additionnelle : il ne remplace pas le 30 mA exigé pour les circuits sensibles.",[17,21617,21618],{},"Une mesure exactement égale à 30 ohms n’est pas supérieure à 30 ohms. Faites évaluer la prise de terre et la répartition par une personne compétente.",[12,21620,21622],{"id":21621},"salle-de-bains-le-30-ma-ne-suffit-pas-à-lui-seul","Salle de bains : le 30 mA ne suffit pas à lui seul",[17,21624,21625],{},"Les circuits qui alimentent un local avec baignoire et\u002Fou douche doivent, selon la sous-section 7.1.4.3, être protégés par un ou plusieurs DDR à haute ou très haute sensibilité, installés à l’extérieur du local. Les volumes 0, 1 et 2, l’indice de protection du matériel et la liaison équipotentielle restent distincts : un 30 mA ne rend pas une prise en volume interdit automatiquement autorisée.",[17,21627,21628],{},"Le Livre 1 prévoit des dispositions transitoires ciblées pour les salles de bains existantes et certains projets commencés avant le 1er mars 2025. Ce ne sont pas des règles générales pour une salle de bains neuve : alimenter un autre local ne supprime pas les exigences du chapitre 7.1.",[12,21630,21632],{"id":21631},"transition-pour-les-installations-commencées-avant-le-1er-juin-2023","Transition pour les installations commencées avant le 1er juin 2023",[17,21634,21635,21636,21639],{},"Pour les parties existantes dont l’exécution sur place a commencé ",[221,21637,21638],{},"avant le 1er juin 2023",", la sous-section 6.5.8.1, point 1, prévoit une dérogation précise ; le contrôle de conformité avant mise en usage a alors lieu à partir du 1er juin 2023. Les circuits visés peuvent rester en service sans la protection sensible actuelle, y compris après certaines modifications non importantes. Plus de huit circuits peuvent aussi rester derrière un DDR sensible et une configuration existante peut regrouper l’éclairage sur un DDR et chaque autre circuit ou groupe sur au maximum seize socles.",[17,21641,21642],{},"Ce n’est pas une exemption automatique : la partie existante, la date et les conditions du contrôle doivent correspondre. L’organisme agréé doit être informé et mentionner la dérogation dans son rapport. Une modification importante peut imposer le DDR requis à l’origine pour toute l’installation. Une installation neuve ou commencée après le 1er juin 2023 ne peut pas invoquer cette transition.",[12,21644,21646],{"id":21645},"aucune-garantie-dabsence-de-coupure","Aucune garantie d’absence de coupure",[17,21648,21649],{},"Un différentiel déclenche lorsqu’il détecte un courant de défaut. C’est une fonction de sécurité, pas une promesse d’alimentation ininterrompue. Une fuite, l’humidité ou un appareil défectueux peuvent provoquer un déclenchement. Plusieurs DDR peuvent limiter les conséquences, sans empêcher le déclenchement ni prouver la conformité.",[12,21651,21653],{"id":21652},"dessiner-exporter-puis-faire-contrôler","Dessiner, exporter, puis faire contrôler",[17,21655,6951,21656,21658,21659,21661],{},[203,21657,5823],{"href":1204},", vous pouvez saisir les circuits, les différentiels et les prises dans l’éditeur, exporter un PDF et lancer un ",[221,21660,20117],{},". Cet outil rend les informations et les points à vérifier plus visibles ; il ne constitue pas une attestation de conformité RGIE et ne remplace ni une étude complète, ni des mesures, ni un contrôle officiel.",[12,21663,1173],{"id":1172},[711,21665,21666,21670,21674],{},[714,21667,21668],{},[203,21669,20136],{"href":3283},[714,21671,21672],{},[203,21673,7847],{"href":6216},[714,21675,21676],{},[203,21677,21678],{"href":4789},"Prises : combien par circuit ?",{"title":1212,"searchDepth":1213,"depth":1213,"links":21680},[21681,21682,21683,21684,21685,21686,21687,21688,21689],{"id":21507,"depth":1213,"text":21508},{"id":21517,"depth":1213,"text":21518},{"id":21583,"depth":1213,"text":21584},{"id":21600,"depth":1213,"text":21601},{"id":21621,"depth":1213,"text":21622},{"id":21631,"depth":1213,"text":21632},{"id":21645,"depth":1213,"text":21646},{"id":21652,"depth":1213,"text":21653},{"id":1172,"depth":1213,"text":1173},"2026-03-04","Un différentiel 30 mA ne se place pas par prise et pas automatiquement par circuit. Découvrez les règles du RGIE Livre 1 V06 pour les installations domestiques neuves et existantes.",{},"\u002Fblog\u002F30ma-rcd-per-socket.fr",{"title":21501,"description":21691},"30ma-ddr-par-prise","blog\u002F30ma-rcd-per-socket.fr",[1243,1242,20850,20668,21698,21250,20868,7391,10095,12444,1249,1248,2003],"dispositif différentiel","KSJ2RkZAXo_gGahPdJfZOK1Z-bABCHyHJRa9Ub6rRhY",{"id":21701,"title":21702,"articleId":21703,"body":21704,"category":1228,"date":22093,"description":22094,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":22095,"navigation":1234,"path":22096,"publishDate":22097,"readTime":4995,"refreshInterval":1237,"seo":22098,"slug":22099,"stem":22100,"tags":22101,"__hash__":22103},"blog\u002Fblog\u002Felectrical-plan-costs.fr.md","Combien coûte un plan électrique ? Comparaison des prix 2026","electrical-plan-costs",{"type":9,"value":21705,"toc":22070},[21706,21710,21713,21720,21724,21737,21740,21772,21776,21779,21869,21873,21876,21881,21884,21889,21892,21896,21899,21903,21906,21910,21913,21917,21920,21922,21925,21976,21979,21983,22006,22010,22013,22016,22018,22022,22025,22029,22032,22036,22039,22043,22046,22050,22053,22057,22060,22062,22065],[12,21707,21709],{"id":21708},"réponse-courte-il-nexiste-pas-de-tarif-forfaitaire-belge","Réponse courte : il n'existe pas de tarif forfaitaire belge",[17,21711,21712],{},"Aucun barème officiel belge ne fixe le prix d'un schéma unifilaire et d'un plan de situation. Une offre sérieuse dépend de la mission : les données de relevé sont-elles fiables, faut-il identifier les circuits sur place, la prestation se limite-t-elle au dessin et comprend-elle des calculs, des corrections matérielles, une vérification professionnelle ou le contrôle réglementaire ? Une « fourchette du marché » nationale sans échantillon, date, région ni régime de TVA donnerait une précision trompeuse.",[17,21714,21715,21716,21719],{},"La comparaison utile n'oppose donc pas un prix logiciel à une facture d'électricien. Elle compare ",[221,21717,21718],{},"le même résultat et le même périmètre",". PlanElec est actuellement sans frais de produit pendant l'Early Access. Le temps personnel, les mesures, le matériel, les travaux, l'accompagnement professionnel et le contrôle d'un organisme agréé restent distincts.",[12,21721,21723],{"id":21722},"quels-documents-les-sources-officielles-demandent-elles","Quels documents les sources officielles demandent-elles ?",[17,21725,21726,21727,21731,21732,21736],{},"Le SPF Économie indique que le demandeur présente au minimum les schémas unifilaires, les plans de position et, s'il est disponible, le code EAN. Le schéma reprend notamment les canalisations et leur mode de pose, les différentiels, les protections contre les surintensités, interrupteurs, boîtes, prises, points lumineux, appareils fixes et sources. Le plan de position localise les éléments correspondants. Ces pièces et les rapports de contrôle composent le dossier de l'installation. La ",[203,21728,21730],{"href":6185,"rel":21729},[5373],"page officielle sur le contrôle domestique"," et le ",[203,21733,21735],{"href":5371,"rel":21734},[5373],"RGIE Livre 1 version 06"," sont les sources primaires de cette synthèse.",[17,21738,21739],{},"Le motif du dossier détermine ensuite l'étendue du travail :",[711,21741,21742,21748,21754,21760,21766],{},[714,21743,21744,21747],{},[221,21745,21746],{},"Nouvelle installation :"," les schémas, le plan de position et le contrôle avant mise en usage font partie du projet.",[714,21749,21750,21753],{},[221,21751,21752],{},"Modification ou extension importante :"," la modification et son influence sur la partie existante doivent être documentées et contrôlées. L'ajout d'un circuit est un exemple officiel.",[714,21755,21756,21759],{},[221,21757,21758],{},"Modification non importante :"," une description succincte, datée et signée peut suffire, mais le plan de position doit continuer à montrer la situation réelle.",[714,21761,21762,21765],{},[221,21763,21764],{},"Vente d'une unité d'habitation :"," le contrôle prévu est réalisé et le dossier disponible est transmis. Un croquis de traçabilité dressé en l'absence de plans n'est pas automatiquement un schéma réglementaire complet.",[714,21767,21768,21771],{},[221,21769,21770],{},"Contrôle périodique ou renforcement du raccordement :"," le déclencheur exact détermine les documents applicables.",[12,21773,21775],{"id":21774},"définir-la-mission-avant-de-comparer-le-prix","Définir la mission avant de comparer le prix",[17,21777,21778],{},"Une offre ne devient comparable que lorsque chaque prestation est écrite.",[21,21780,21781,21791],{},[24,21782,21783],{},[27,21784,21785,21788],{},[30,21786,21787],{},"Prestation",[30,21789,21790],{},"Question à clarifier",[43,21792,21793,21800,21808,21815,21822,21830,21838,21846,21853,21861],{},[27,21794,21795,21797],{},[48,21796,13914],{},[48,21798,21799],{},"Les locaux, prises, appareils fixes, chemins de câbles et tableaux sont-ils relevés sur place ou fournis sous forme de données vérifiées ?",[27,21801,21802,21805],{},[48,21803,21804],{},"Identification des circuits",[48,21806,21807],{},"Les affectations sont-elles connues ou doivent-elles être établies par commutation sûre, examen et mesure ?",[27,21809,21810,21812],{},[48,21811,5869],{},[48,21813,21814],{},"Les caractéristiques des protections, conducteurs, modes de pose, sources et appareils fixes sont-elles incluses ?",[27,21816,21817,21819],{},[48,21818,6995],{},[48,21820,21821],{},"Existe-t-il un plan exploitable et toutes les références correspondent-elles au schéma ?",[27,21823,21824,21827],{},[48,21825,21826],{},"Calculs",[48,21828,21829],{},"Le dimensionnement, le courant de défaut, la sélectivité ou la chute de tension font-ils réellement partie de la mission ?",[27,21831,21832,21835],{},[48,21833,21834],{},"Relecture technique",[48,21836,21837],{},"Un professionnel vérifie-t-il la plausibilité ou la prestation est-elle uniquement graphique ?",[27,21839,21840,21843],{},[48,21841,21842],{},"Travaux correctifs",[48,21844,21845],{},"Les interventions au tableau, aux câbles ou au matériel sont-elles comprises ?",[27,21847,21848,21850],{},[48,21849,13957],{},[48,21851,21852],{},"La rétribution de l'organisme agréé est-elle comprise ou séparée ?",[27,21854,21855,21858],{},[48,21856,21857],{},"Corrections",[48,21859,21860],{},"Combien de cycles de correction motivée sont inclus ?",[27,21862,21863,21866],{},[48,21864,21865],{},"TVA et déplacements",[48,21867,21868],{},"Le montant inclut-il TVA, trajet et éventuelle seconde visite ?",[12,21870,21872],{"id":21871},"un-modèle-de-calcul-modifiable-pas-un-prix-inventé","Un modèle de calcul modifiable, pas un prix inventé",[17,21874,21875],{},"N'inscrivez que des montants issus d'une offre réelle et votre propre valorisation du temps. La formule suivante est un outil de décision, pas une promesse commerciale :",[17,21877,21878],{},[4068,21879,21880],{},"total du scénario = relevé + dessin + vérification + travaux + contrôle + déplacement + temps personnel",[17,21882,21883],{},"Le temps personnel peut devenir visible avec :",[17,21885,21886],{},[4068,21887,21888],{},"temps valorisé = heures notées × valeur de comparaison personnelle",[17,21890,21891],{},"Cette valeur n'est ni une facture ni un tarif horaire belge. Elle évite simplement de considérer automatiquement un week-end de travail comme gratuit. Inversement, un forfait professionnel n'est pas cher par définition s'il comprend le relevé, les mesures, la responsabilité technique et les corrections.",[5686,21893,21895],{"id":21894},"scénario-a-les-données-sont-vérifiées","Scénario A : les données sont vérifiées",[17,21897,21898],{},"Le tableau est clairement identifié, l'affectation des circuits est contrôlée, un plan exploitable existe et les données des protections sont lisibles. Le travail porte alors surtout sur la saisie, la cohérence et le dessin. PlanElec peut centraliser le modèle du projet, le plan, la topologie et les PDF ; un électricien peut réaliser une relecture ciblée.",[5686,21900,21902],{"id":21901},"scénario-b-ancienne-installation-sans-dossier-fiable","Scénario B : ancienne installation sans dossier fiable",[17,21904,21905],{},"Lorsque sections, modes de pose ou affectations sont inconnus, le dessin n'est que la dernière étape. Une personne compétente doit d'abord établir l'état réel en sécurité. Une personne non qualifiée ne doit pas ouvrir des enveloppes ni effectuer des mesures électriques. Le relevé peut donc représenter plus de travail que le dessin, et aucun logiciel ne supprime cette étape.",[5686,21907,21909],{"id":21908},"scénario-c-rénovation-encore-à-concevoir","Scénario C : rénovation encore à concevoir",[17,21911,21912],{},"De nouveaux circuits, du photovoltaïque, une batterie, une borne, une pompe à chaleur ou une modification du tableau imposent des choix techniques avant la documentation. Le schéma enregistre la décision ; il ne la prend pas. Demandez des postes séparés pour relevé, étude, prescriptions du fabricant, conditions du gestionnaire de réseau, exécution et contrôle.",[5686,21914,21916],{"id":21915},"scénario-d-vente-avec-échéance","Scénario D : vente avec échéance",[17,21918,21919],{},"Une échéance ne prouve pas l'existence d'un supplément urgent standard. Demandez une offre écrite avec délai, prérequis et procédure de correction. Déterminez qui commande le contrôle et quels anciens rapports appartiennent au dossier. Un plan rapide qui ne correspond pas à l'installation ne résout rien.",[12,21921,14030],{"id":14029},[17,21923,21924],{},"Dans l'état Dev\u002FPilote actuel, PlanElec relie plan du bâtiment, topologie électrique et tableau dans un même projet. Le schéma unifilaire et le plan de situation sont exportables en PDF. L'auto-contrôle RGIE assisté ne traite que les règles prises en charge et décidables à partir des données enregistrées ; les informations manquantes restent visibles. La liste détaillée et neutre de matériel ainsi que le dossier de travail configurable sont des fonctions pilotes, pas une liste prête à commander ni un rapport officiel. Les devis et paiements ne sont pas actifs.",[21,21926,21927,21936],{},[24,21928,21929],{},[27,21930,21931,21933],{},[30,21932,584],{},[30,21934,21935],{},"Situation au 29 août 2026",[43,21937,21938,21946,21953,21961,21969],{},[27,21939,21940,21943],{},[48,21941,21942],{},"Frais de produit PlanElec",[48,21944,21945],{},"actuellement 0 EUR",[27,21947,21948,21951],{},[48,21949,21950],{},"Paiement actif",[48,21952,865],{},[27,21954,21955,21958],{},[48,21956,21957],{},"Pilote B2B payant",[48,21959,21960],{},"prévu, conditions non publiées",[27,21962,21963,21966],{},[48,21964,21965],{},"Vérification électrique professionnelle",[48,21967,21968],{},"prestation distincte si nécessaire",[27,21970,21971,21973],{},[48,21972,13957],{},[48,21974,21975],{},"prestation d'un organisme agréé",[17,21977,21978],{},"Zéro frais de produit ne signifie donc pas une économie totale fixe. Un projet aux données complètes n'a pas la même charge qu'une installation inconnue à relever.",[12,21980,21982],{"id":21981},"obtenir-des-offres-comparables","Obtenir des offres comparables",[5034,21984,21985,21988,21991,21994,21997,22000,22003],{},[714,21986,21987],{},"Décrivez le bâtiment, le raccordement, les tableaux et circuits connus.",[714,21989,21990],{},"Mentionnez PV, batterie, borne, pompe à chaleur et autres sources ou charges particulières.",[714,21992,21993],{},"Fournissez les plans et rapports existants sans deviner les données manquantes.",[714,21995,21996],{},"Demandez des postes séparés pour relevé, dessin, étude, exécution et contrôle.",[714,21998,21999],{},"Vérifiez TVA, déplacement, format livré et corrections comprises.",[714,22001,22002],{},"Comparez responsabilité et couverture, pas seulement le total.",[714,22004,22005],{},"Après les travaux, mettez le dossier à jour selon l'état réel.",[12,22007,22009],{"id":22008},"définir-la-remise-et-les-révisions-comme-prestations","Définir la remise et les révisions comme prestations",[17,22011,22012],{},"Une offre ne devrait pas indiquer seulement « plan PDF », mais préciser l'état documentaire remis. Identifiez les anciens documents vérifiés, les données fournies par le client et les inconnues maintenues ouvertes. Convenez du nombre de corrections incluses, de la personne qui communique les changements après chantier et de la version qui représentera finalement l'état réalisé.",[17,22014,22015],{},"À la réception, comparez les repères entre tableau, schéma unifilaire et plan de situation, vérifiez les appareils ajoutés ou retirés et conservez fiches et mesures auprès du dossier correspondant. Cette remise rend comparables dessin, examen professionnel et maintenance future sans inventer de prix moyen ni d'économie garantie.",[12,22017,7801],{"id":7800},[5686,22019,22021],{"id":22020},"quelles-données-réunir-avant-de-demander-une-offre","Quelles données réunir avant de demander une offre ?",[17,22023,22024],{},"Commencez par les informations disponibles sans intervention dangereuse : adresse et type de raccordement, nombre et emplacement des tableaux, caractéristiques lisibles des différentiels et protections, libellés des circuits, plan du bâtiment, anciens schémas et rapports. Relevez séparément les charges fixes et les sources. Marquez une inconnue comme telle. Inventer une section de conducteur rend le dessin apparemment complet mais techniquement moins fiable. Des photos préparent le relevé ; elles ne remplacent ni mesure ni identification sûre d'un câblage caché.",[5686,22026,22028],{"id":22027},"quelles-prestations-ne-doivent-pas-disparaître-dans-un-prix-du-plan","Quelles prestations ne doivent pas disparaître dans un « prix du plan » ?",[17,22030,22031],{},"Une modification physique, une recherche de panne, des procès-verbaux de mesure, un dimensionnement selon le fabricant et la correction d'une infraction diffèrent du dessin. Les démarches du gestionnaire de réseau pour une production ou un stockage ne sont pas incluses automatiquement. Si elles sont nécessaires, inscrivez-les comme livrables séparés avec responsable et date. Le client sait ce qui est livré et l'entreprise n'endosse pas implicitement des parties inconnues ou non commandées.",[5686,22033,22035],{"id":22034},"comment-gérer-une-modification-après-le-premier-export","Comment gérer une modification après le premier export ?",[17,22037,22038],{},"Conservez une version de référence traçable, enregistrez les changements confirmés dans le projet et le plan de situation et faites vérifier les modifications techniques. N'écrivez pas seulement « cuisine modifiée » : identifiez circuit, protection, câble et points concernés. La révision suivante reste alors ciblée au lieu de devenir un nouveau relevé complet.",[5686,22040,22042],{"id":22041},"puis-je-dessiner-moi-même","Puis-je dessiner moi-même ?",[17,22044,22045],{},"Les règles officielles fixent le contenu, l'identification et la responsabilité. Les documents doivent représenter fidèlement l'installation et suivre la procédure de contrôle applicable. Le dessin personnel ne remplace pas un relevé sûr ni un travail électrique compétent.",[5686,22047,22049],{"id":22048},"un-pdf-planelec-prouve-t-il-la-conformité","Un PDF PlanElec prouve-t-il la conformité ?",[17,22051,22052],{},"Non. Il documente les données saisies. L'auto-contrôle est indicatif et incomplet. Seul un organisme agréé statue dans la procédure officielle sur l'installation contrôlée.",[5686,22054,22056],{"id":22055},"quel-est-le-principal-facteur-de-coût","Quel est le principal facteur de coût ?",[17,22058,22059],{},"Il n'est pas universel. L'incertitude sur l'existant et le périmètre commandé comptent souvent plus que la superficie seule. Des données vérifiées réduisent le relevé ; des câbles inconnus, plusieurs tableaux et des modifications l'augmentent.",[12,22061,13777],{"id":13776},[17,22063,22064],{},"Le prix sérieux d'un plan électrique est une offre liée au projet, pas une fourchette Internet sans source. Séparez relevé, dessin, vérification, travaux et contrôle, valorisez votre propre temps et comparez des prestations identiques. PlanElec soutient la documentation structurée sans garantir économie, conformité ni contrôle positif.",[17,22066,22067],{},[203,22068,22069],{"href":7861},"Structurer le projet dans l'Early Access actuellement gratuit →",{"title":1212,"searchDepth":1213,"depth":1213,"links":22071},[22072,22073,22074,22075,22081,22082,22083,22084,22092],{"id":21708,"depth":1213,"text":21709},{"id":21722,"depth":1213,"text":21723},{"id":21774,"depth":1213,"text":21775},{"id":21871,"depth":1213,"text":21872,"children":22076},[22077,22078,22079,22080],{"id":21894,"depth":5848,"text":21895},{"id":21901,"depth":5848,"text":21902},{"id":21908,"depth":5848,"text":21909},{"id":21915,"depth":5848,"text":21916},{"id":14029,"depth":1213,"text":14030},{"id":21981,"depth":1213,"text":21982},{"id":22008,"depth":1213,"text":22009},{"id":7800,"depth":1213,"text":7801,"children":22085},[22086,22087,22088,22089,22090,22091],{"id":22020,"depth":5848,"text":22021},{"id":22027,"depth":5848,"text":22028},{"id":22034,"depth":5848,"text":22035},{"id":22041,"depth":5848,"text":22042},{"id":22048,"depth":5848,"text":22049},{"id":22055,"depth":5848,"text":22056},{"id":13776,"depth":1213,"text":13777},"2026-02-19","Les prestations qui déterminent le prix d'un plan électrique belge et une méthode de calcul modifiable pour comparer les offres sans promesse d'économie.",{},"\u002Fblog\u002Felectrical-plan-costs.fr",null,{"title":21702,"description":22094},"cout-plan-electrique","blog\u002Felectrical-plan-costs.fr",[1243,1242,1248,20666,8422,20667,14138,22102,18549,10095,14139,11129,1249,20671,20672],"prix","fhXRwU-SHF35h7nfbOe5lFQvpGgXWsKSdvnbbvnC8lg",{"id":22105,"title":22106,"articleId":22107,"body":22108,"category":1228,"date":22467,"description":22468,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":22469,"navigation":1234,"path":22470,"publishDate":22097,"readTime":8416,"refreshInterval":1237,"seo":22471,"slug":11815,"stem":22472,"tags":22473,"__hash__":22476},"blog\u002Fblog\u002Felectrical-inspection.fr.md","Contrôle Électrique en Belgique : Le Guide Complet 2026","electrical-inspection",{"type":9,"value":22109,"toc":22449},[22110,22114,22117,22120,22124,22127,22164,22172,22176,22179,22183,22186,22204,22208,22211,22234,22238,22241,22261,22265,22268,22294,22297,22301,22308,22311,22315,22322,22325,22342,22345,22349,22352,22355,22358,22362,22365,22368,22372,22376,22379,22382,22385,22392,22396,22399,22401,22407,22439,22444],[12,22111,22113],{"id":22112},"quest-ce-quun-contrôle-électrique","Qu'est-ce qu'un Contrôle Électrique ?",[17,22115,22116],{},"En Belgique, les installations électriques sont contrôlées par un organisme agréé aux moments définis par le RGIE : notamment avant la mise en usage d'une nouvelle installation, lors d'une modification ou extension importante, périodiquement et dans certaines ventes.",[17,22118,22119],{},"La procédure dépend du cas. Le contrôle « vente » d'une ancienne installation n'est pas le contrôle de conformité d'une construction neuve. Une durée ou un surcoût fixe ne peut pas être annoncé sans connaître le projet et le prestataire.",[12,22121,22123],{"id":22122},"quand-avez-vous-besoin-dun-contrôle","Quand avez-vous besoin d'un contrôle ?",[17,22125,22126],{},"Un contrôle électrique est requis dans les situations suivantes :",[711,22128,22129,22135,22141,22146,22152,22158],{},[714,22130,22131,22134],{},[221,22132,22133],{},"Nouvelles installations"," : Avant le premier raccordement au réseau électrique",[714,22136,22137,22140],{},[221,22138,22139],{},"Modifications ou extensions importantes"," : par exemple l'ajout d'un circuit au tableau ; une petite modification est traitée autrement",[714,22142,22143,22145],{},[221,22144,16020],{}," : Tous les 25 ans pour les bâtiments résidentiels",[714,22147,22148,22151],{},[221,22149,22150],{},"Vente immobilière"," : Visite de contrôle lors de la vente d'une unité d'habitation",[714,22153,22154,22157],{},[221,22155,22156],{},"Après un rapport d'infraction"," : Recontrôle après correction des problèmes identifiés",[714,22159,22160,22163],{},[221,22161,22162],{},"Renforcement de puissance"," : dans les cas prévus pour certaines anciennes installations domestiques",[9883,22165,22166],{},[17,22167,22168,22171],{},[221,22169,22170],{},"Bon à savoir"," : Même si vous n'ajoutez que quelques nouveaux circuits, un recontrôle complet peut être déclenché. Vérifiez toujours auprès de votre électricien ou organisme de contrôle au préalable.",[12,22173,22175],{"id":22174},"comment-se-préparer-au-contrôle","Comment se préparer au contrôle",[17,22177,22178],{},"Une bonne préparation rend l'installation contrôlable, sans garantir une conclusion positive. Préparez notamment :",[5686,22180,22182],{"id":22181},"_1-documentation-requise","1. Documentation requise",[17,22184,22185],{},"L'inspecteur demandera les documents suivants :",[711,22187,22188,22193,22198],{},[714,22189,22190,22192],{},[221,22191,5869],{}," — Un aperçu schématique de tous les circuits, dispositifs de protection et raccordements",[714,22194,22195,22197],{},[221,22196,6995],{}," — Indique l'emplacement physique de tous les composants électriques",[714,22199,22200,22203],{},[221,22201,22202],{},"Documents techniques"," utiles pour les équipements particuliers comme PV, borne ou batterie",[5686,22205,22207],{"id":22206},"_2-exigences-de-linstallation","2. Exigences de l'installation",[17,22209,22210],{},"Assurez-vous que votre installation répond à ces exigences de base :",[711,22212,22213,22216,22219,22222,22225,22228,22231],{},[714,22214,22215],{},"Tous les circuits sont correctement protégés par des disjoncteurs",[714,22217,22218],{},"Un différentiel de 300mA protège l'ensemble de l'installation",[714,22220,22221],{},"Protection différentielle supplémentaire de 30mA (haute ou très haute sensibilité) pour les circuits de prises de courant, l'éclairage, les pièces humides (salle de bain\u002Fdouche), ainsi que les lave-linge, sèche-linge et lave-vaisselle",[714,22223,22224],{},"Mise à la terre correcte avec une résistance maximale de 30 Ohms (RGIE Art. 4.2.4.3b : en cas de dépassement de 30 Ω, des dispositifs différentiels à haute sensibilité supplémentaires sont requis ; formule générale : R_A × I∆n ≤ 50 V)",[714,22226,22227],{},"Tous les câbles sont correctement fixés et protégés",[714,22229,22230],{},"Les boîtes de dérivation sont accessibles et correctement fermées",[714,22232,22233],{},"Au moins deux circuits d'éclairage séparés pour les appartements de plus de deux pièces (Art. 5.3.5.2b)",[5686,22235,22237],{"id":22236},"_3-erreurs-courantes-à-éviter","3. Erreurs courantes à éviter",[17,22239,22240],{},"Ces points méritent une attention particulière ; aucune statistique ni hiérarchie non sourcée n'est affirmée ici :",[711,22242,22243,22246,22249,22252,22255,22258],{},[714,22244,22245],{},"Schéma unifilaire manquant ou incorrect",[714,22247,22248],{},"Protection différentielle insuffisante",[714,22250,22251],{},"Résistance de terre trop élevée",[714,22253,22254],{},"Câbles mal fixés ou non protégés",[714,22256,22257],{},"Couvercles manquants sur les boîtes de dérivation",[714,22259,22260],{},"Moins de deux circuits d'éclairage séparés pour les appartements de plus de deux pièces",[12,22262,22264],{"id":22263},"que-se-passe-t-il-pendant-le-contrôle","Que se passe-t-il pendant le contrôle ?",[17,22266,22267],{},"La portée et la durée dépendent de l'installation et du type de contrôle. Le représentant va notamment :",[5034,22269,22270,22276,22282,22288],{},[714,22271,22272,22275],{},[221,22273,22274],{},"Vérifier la documentation"," — S'assurer que le schéma unifilaire et le plan de situation correspondent à l'installation réelle",[714,22277,22278,22281],{},[221,22279,22280],{},"Inspection visuelle"," — Contrôler tous les composants, câbles et connexions visibles",[714,22283,22284,22287],{},[221,22285,22286],{},"Effectuer des mesures"," — Tester la résistance de terre, la résistance d'isolement et l'impédance de boucle",[714,22289,22290,22293],{},[221,22291,22292],{},"Tests fonctionnels"," — Tester tous les différentiels et disjoncteurs",[17,22295,22296],{},"Après le contrôle, vous recevez un rapport écrit ou électronique. Il mentionne la conclusion, les infractions et la suite éventuelle. Les 25 ans souvent cités correspondent à la périodicité ordinaire après un premier contrôle positif d'une installation domestique ; ce n'est pas un « certificat vert » universel.",[12,22298,22300],{"id":22299},"déterminer-dabord-le-type-de-contrôle","Déterminer d'abord le type de contrôle",[17,22302,1759,22303,22307],{},[203,22304,22306],{"href":11060,"rel":22305},[5373],"page officielle du SPF Economie"," distingue plusieurs procédures. Une installation neuve et une modification ou extension importante font l'objet d'un contrôle de conformité avant mise en usage. Le contrôle périodique suit la sécurité pendant l'exploitation. Le contrôle lors de la vente vise certaines anciennes installations domestiques qui n'ont pas subi l'examen complet concerné. Le renforcement de puissance possède encore d'autres conditions.",[17,22309,22310],{},"Cette distinction détermine les délais et la portée. Pour une extension importante, l'organisme considère les travaux et leurs effets possibles sur la partie inchangée. Une modification non importante n'entraîne pas nécessairement le même contrôle, mais le dossier doit rester à jour. Décrivez les travaux réels plutôt que de les résumer par le mot « rénovation ».",[12,22312,22314],{"id":22313},"comparer-les-plans-avec-linstallation","Comparer les plans avec l'installation",[17,22316,1759,22317,22321],{},[203,22318,22320],{"href":6185,"rel":22319},[5373],"page fédérale sur le contrôle domestique"," demande au minimum les schémas unifilaires, les plans de situation et, s'il est disponible, le code EAN. Le schéma décrit les circuits, connexions et caractéristiques du matériel. Le plan situe les tableaux, boîtes, prises, points lumineux, interrupteurs, machines fixes et sources auxquels il fait référence.",[17,22323,22324],{},"Effectuez un rapprochement systématique :",[5034,22326,22327,22330,22333,22336,22339],{},[714,22328,22329],{},"les repères de circuits correspondent-ils au tableau et sur les deux plans ?",[714,22331,22332],{},"calibres, nombre de pôles, type et section des câbles sont-ils corrects ?",[714,22334,22335],{},"les prises, luminaires, appareils fixes et sources ajoutés figurent-ils sur les plans ?",[714,22337,22338],{},"les boîtes de connexion et de dérivation restent-elles repérables et accessibles ?",[714,22340,22341],{},"les notices du PV, de la borne, de la batterie ou d'un autre matériel spécial sont-elles disponibles ?",[17,22343,22344],{},"Un beau dessin ne suffit pas s'il décrit un état ancien. Inversement, une réalisation correcte n'efface pas l'obligation documentaire. Notez les incertitudes et résolvez-les avant le rendez-vous.",[12,22346,22348],{"id":22347},"préparer-lexamen-les-essais-et-les-mesures","Préparer l'examen, les essais et les mesures",[17,22350,22351],{},"L'organisme compare les documents avec l'état visible et réalise les essais et mesures prévus. Il ne faut ni inventer de valeurs ni recopier celles d'un ancien rapport. Résistance de terre, isolement et fonctionnement des protections s'apprécient sur l'installation présente.",[17,22353,22354],{},"Rendez accessibles le tableau, la barrette de coupure de terre et les locaux concernés. Les étiquettes doivent être lisibles et les enveloppes complètes. Signalez la production locale, la batterie, la fonction de secours, la recharge et les parties anciennes. L'ouverture d'appareils ou les mesures sous tension ne sont pas des tâches de préparation pour un particulier.",[17,22356,22357],{},"Les chiffres simples demandent aussi du contexte. Trente ohms n'est pas un verdict universel pour toute mise à la terre : le Livre 1 relie résistance de terre, protection différentielle et tension de contact admissible. La protection d'un câble dépend de sa section, mais aussi du matériau, de la pose, du groupement, de la température, de la longueur et du dispositif choisi.",[12,22359,22361],{"id":22360},"suivre-le-rapport-et-le-bon-délai","Suivre le rapport et le bon délai",[17,22363,22364],{},"Un rapport positif consigne une appréciation à un moment et pour une portée définis. Il ne supprime ni l'entretien ni un nouveau contrôle après de futurs travaux importants. Conservez-le avec le dossier et notez les petites modifications ultérieures.",[17,22366,22367],{},"En cas de rapport négatif, traitez chaque infraction. Lors d'un contrôle avant mise en usage, la partie concernée ne peut être utilisée avant correction et nouveau contrôle. Après un contrôle périodique négatif, les informations fédérales prévoient une visite complémentaire par le même organisme dans les douze mois. Pour le contrôle « vente » d'une ancienne habitation concernée, l'acheteur dispose en principe de dix-huit mois à compter de l'acte authentique pour remettre en ordre et faire réaliser une nouvelle visite. Le type de contrôle et le rapport restent déterminants.",[12,22369,22371],{"id":22370},"employer-planelec-dans-son-périmètre-réel","Employer PlanElec dans son périmètre réel",[12,22373,22375],{"id":22374},"lors-de-la-réservation-et-le-jour-du-contrôle","Lors de la réservation et le jour du contrôle",[17,22377,22378],{},"Indiquez à l'organisme l'usage domestique, le type de contrôle, le nombre de tableaux et la présence de PV, batterie, secours ou borne. Demandez quels documents doivent être imprimés ou numériques, quels accès prévoir et confirmez directement le tarif actuel. Pour une vente, mentionnez l'âge et les anciens rapports ; pour une extension, séparez clairement existant et neuf.",[17,22380,22381],{},"Prévoyez un interlocuteur connaissant l'installation, rendez tableaux et barrette de terre accessibles en sécurité et ne modifiez rien improvisé pendant la visite. À réception, vérifiez adresse, type, portée et liste des documents. Posez toute question technique par écrit en citant le constat exact et conservez le rapport final avec les plans présentés.",[17,22383,22384],{},"PlanElec transforme la topologie saisie en schéma unifilaire et plan de situation, produit des PDF et signale certains problèmes de conception déductibles des données. Son autocontrôle n'est pas une attestation de conformité. Il ne voit pas les canalisations cachées, n'effectue aucune mesure et ne connaît pas automatiquement chaque notice ou dérogation ancienne.",[17,22386,22387,22388,212],{},"Utilisez-le comme base documentaire cohérente : saisir, comparer avec la réalisation, faire vérifier les incertitudes, puis exporter. La conclusion officielle appartient à l'organisme agréé. Le ",[203,22389,22391],{"href":12074,"rel":22390},[5373],"SPF Economie en publie la liste",[12,22393,22395],{"id":22394},"consigner-le-périmètre-contrôlé-après-la-visite","Consigner le périmètre contrôlé après la visite",[17,22397,22398],{},"Notez quels tableaux, locaux, sources d'énergie et modes de fonctionnement étaient accessibles et réellement compris dans le contrôle. Comparez cette limite avec le libellé du rapport. Un rapport positif pour une partie clairement délimitée ne se prononce pas sur les ajouts ultérieurs ni sur les zones non inspectées. Si des canalisations fixes, protections, fonctions photovoltaïques, batterie ou recharge changent après la visite, actualisez les plans et le dossier, puis déterminez quel nouveau contrôle est requis. Conservez sans modification la version des plans présentée au rendez-vous avec le rapport ; créez une nouvelle version datée pour les travaux suivants. Il reste ainsi possible d'identifier l'état effectivement évalué par l'organisme.",[12,22400,12167],{"id":12166},[17,22402,22403,22404,22406],{},"La création de la documentation requise est souvent la partie la plus chronophage de la préparation d'un contrôle électrique. ",[221,22405,5823],{}," simplifie considérablement ce processus :",[711,22408,22409,22415,22421,22427,22433],{},[714,22410,22411,22414],{},[221,22412,22413],{},"Créer des schémas unifilaires structurés"," à partir des circuits saisis",[714,22416,22417,22420],{},[221,22418,22419],{},"Bibliothèque de symboles belges"," pour les représentations prises en charge",[714,22422,22423,22426],{},[221,22424,22425],{},"Plans de situation"," basés sur le plan d'étage saisi",[714,22428,22429,22432],{},[221,22430,22431],{},"Export en PDF"," pour une soumission facile à l'inspecteur",[714,22434,22435,22438],{},[221,22436,22437],{},"Support multilingue"," — Documentation en néerlandais, français, allemand ou anglais",[9883,22440,22441],{},[17,22442,22443],{},"Comparez l'export à l'installation réalisée et faites valider dimensionnement, mesures et questions techniques par un professionnel.",[17,22445,22446],{},[203,22447,22448],{"href":7861},"Commencez gratuitement votre documentation électrique →",{"title":1212,"searchDepth":1213,"depth":1213,"links":22450},[22451,22452,22453,22458,22459,22460,22461,22462,22463,22464,22465,22466],{"id":22112,"depth":1213,"text":22113},{"id":22122,"depth":1213,"text":22123},{"id":22174,"depth":1213,"text":22175,"children":22454},[22455,22456,22457],{"id":22181,"depth":5848,"text":22182},{"id":22206,"depth":5848,"text":22207},{"id":22236,"depth":5848,"text":22237},{"id":22263,"depth":1213,"text":22264},{"id":22299,"depth":1213,"text":22300},{"id":22313,"depth":1213,"text":22314},{"id":22347,"depth":1213,"text":22348},{"id":22360,"depth":1213,"text":22361},{"id":22370,"depth":1213,"text":22371},{"id":22374,"depth":1213,"text":22375},{"id":22394,"depth":1213,"text":22395},{"id":12166,"depth":1213,"text":12167},"2026-01-08","Tout ce que vous devez savoir sur le contrôle électrique — de la préparation à l'inspection finale.",{},"\u002Fblog\u002Felectrical-inspection.fr",{"title":22106,"description":22468},"blog\u002Felectrical-inspection.fr",[1243,1242,10095,22474,1248,20666,8422,20667,22475,20668,1246,14139,1249,20671,20672],"keuring","conformité","1rKs4EEbNHCpHdxeRfe6J7rl6kAoW8lN3wM5YUMuR9E",{"id":22478,"title":22479,"articleId":22480,"body":22481,"category":5859,"date":22986,"description":22987,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":22988,"navigation":1234,"path":22989,"publishDate":22097,"readTime":22990,"refreshInterval":1237,"seo":22991,"slug":12918,"stem":22992,"tags":22993,"__hash__":22995},"blog\u002Fblog\u002Fsingle-line-diagram.fr.md","Schéma unifilaire en Belgique : guide RGIE étape par étape","single-line-diagram",{"type":9,"value":22482,"toc":22956},[22483,22490,22494,22502,22505,22509,22512,22544,22551,22554,22557,22560,22583,22586,22612,22616,22634,22638,22642,22645,22670,22674,22677,22702,22705,22709,22712,22726,22730,22733,22758,22762,22769,22772,22776,22780,22783,22787,22790,22794,22797,22811,22815,22818,22822,22854,22858,22861,22864,22868,22871,22874,22878,22881,22885,22888,22892,22902,22905,22909,22912,22926,22931,22933],[9883,22484,22485],{},[17,22486,22487,22489],{},[221,22488,17721],{}," le schéma unifilaire représente la structure électrique de l'installation, du tableau aux circuits et aux récepteurs. En Belgique, il fait partie du dossier utilisé lors du contrôle. Ce guide explique les symboles, les informations à reprendre, la méthode de création et l'export PDF.",[12,22491,22493],{"id":22492},"quest-ce-quun-schéma-unifilaire","Qu'est-ce qu'un schéma unifilaire ?",[17,22495,22496,22497,21268,22499,22501],{},"Un schéma unifilaire (néerlandais : ",[60,22498,20666],{},[60,22500,20671],{},") est un schéma électrique simplifié qui représente la structure de votre installation complète à l'aide de symboles standardisés. Contrairement à un schéma de câblage qui montre chaque conducteur individuel, un schéma unifilaire utilise une seule ligne pour représenter chaque circuit.",[17,22503,22504],{},"Ce document fait partie des pièces demandées en Belgique lors du contrôle électrique selon le RGIE. Il doit être à jour et correspondre à l'installation réelle ; le contrôle officiel reste du ressort d'un organisme agréé.",[12,22506,22508],{"id":22507},"pourquoi-est-ce-important","Pourquoi est-ce important ?",[17,22510,22511],{},"Le schéma unifilaire remplit plusieurs fonctions essentielles :",[711,22513,22514,22520,22526,22532,22538],{},[714,22515,22516,22519],{},[221,22517,22518],{},"Documentation prescrite"," — Pour une nouvelle installation domestique et une modification ou extension importante",[714,22521,22522,22525],{},[221,22523,22524],{},"Vue d'ensemble de la sécurité"," — Montre tous les dispositifs de protection et leur coordination",[714,22527,22528,22531],{},[221,22529,22530],{},"Référence de maintenance"," — Aide les électriciens à identifier rapidement les circuits et composants",[714,22533,22534,22537],{},[221,22535,22536],{},"Planification des modifications"," — Indispensable pour planifier les changements futurs",[714,22539,22540,22543],{},[221,22541,22542],{},"Documentation immobilière"," — Requis lors de la vente d'un bien",[9883,22545,22546],{},[17,22547,22548,22550],{},[221,22549,10730],{}," : Les documents décrivent l'état actuel. Pour un changement non important, une description succincte datée peut suffire, tandis que le plan de situation reste actualisé.",[12,22552,6211],{"id":22553},"comprendre-les-symboles-rgie",[17,22555,22556],{},"Le tableau 2.23 du RGIE fournit les symboles de départ. À défaut, un autre symbole non ambigu peut être employé s'il est défini dans la légende. Voici les groupes principaux :",[5686,22558,21428],{"id":22559},"dispositifs-de-protection",[711,22561,22562,22567,22572,22578],{},[714,22563,22564,22566],{},[221,22565,13232],{}," — Protège contre les surintensités",[714,22568,22569,22571],{},[221,22570,13672],{}," (differentieelschakelaar) — Protège contre les fuites à la terre",[714,22573,22574,22577],{},[221,22575,22576],{},"Fusible"," (smeltzekering) — Protection traditionnelle contre les surintensités",[714,22579,22580,22582],{},[221,22581,20523],{}," (hoofdschakelaar) — Déconnecte l'ensemble de l'installation",[5686,22584,1045],{"id":22585},"consommateurs",[711,22587,22588,22594,22600,22606],{},[714,22589,22590,22593],{},[221,22591,22592],{},"Prise de courant"," — Représentée par un symbole en demi-cercle",[714,22595,22596,22599],{},[221,22597,22598],{},"Point d'éclairage"," — Cercle avec rayons ou croix",[714,22601,22602,22605],{},[221,22603,22604],{},"Appareil fixe"," — Rectangle avec désignation de l'appareil",[714,22607,22608,22611],{},[221,22609,22610],{},"Moteur"," — Cercle avec désignation M",[5686,22613,22615],{"id":22614},"symboles-spéciaux","Symboles spéciaux",[711,22617,22618,22623,22629],{},[714,22619,22620,22622],{},[221,22621,151],{}," — Trois lignes horizontales de longueur décroissante",[714,22624,22625,22628],{},[221,22626,22627],{},"Liaison équipotentielle"," — Ligne de connexion avec symbole de terre",[714,22630,22631,22633],{},[221,22632,14682],{}," — Ligne en zigzag avec flèche",[12,22635,22637],{"id":22636},"guide-étape-par-étape-avec-planelec","Guide étape par étape avec PlanElec",[5686,22639,22641],{"id":22640},"étape-1-définir-votre-installation","Étape 1 : Définir votre installation",[17,22643,22644],{},"Commencez par cartographier votre installation électrique :",[5034,22646,22647,22650,22653],{},[714,22648,22649],{},"Ouvrez PlanElec et créez un nouveau projet",[714,22651,22652],{},"Définissez les pièces de votre bâtiment (salon, cuisine, chambres, etc.)",[714,22654,22655,22656],{},"Pour chaque pièce, spécifiez les composants électriques :\n",[711,22657,22658,22661,22664,22667],{},[714,22659,22660],{},"Nombre et type de prises (simple, double, avec broche de terre)",[714,22662,22663],{},"Points d'éclairage (plafond, mur, commuté)",[714,22665,22666],{},"Appareils fixes (four, plaque de cuisson, chauffe-eau, etc.)",[714,22668,22669],{},"Circuits spéciaux (borne de recharge VE, pompe à chaleur, panneaux solaires)",[5686,22671,22673],{"id":22672},"étape-2-configurer-les-dispositifs-de-protection","Étape 2 : Configurer les dispositifs de protection",[17,22675,22676],{},"PlanElec peut proposer des protections comme point de départ à vérifier :",[711,22678,22679,22685,22691,22697],{},[714,22680,22681,22684],{},[221,22682,22683],{},"Protection différentielle générale"," — Maximum 300 mA au point d'alimentation (art. 4.2.4.3b) ; type, calibre et coordination se vérifient pour la chaîne réelle",[714,22686,22687,22690],{},[221,22688,22689],{},"Différentiels 30 mA supplémentaires"," — Pour les prises (hors appareils fixes), l'éclairage, les salles de bains, lave-linge\u002Fsèche-linge\u002Flave-vaisselle (Art. 4.2.4.3b) ; max. 8 circuits terminaux par RCD 30 mA",[714,22692,22693,22696],{},[221,22694,22695],{},"Disjoncteurs"," — Dimensionnés selon la section du câble et le type de circuit",[714,22698,22699,22701],{},[221,22700,17101],{}," — Si requise par votre type d'installation",[17,22703,22704],{},"Vous pouvez ajuster ces suggestions en fonction de vos besoins spécifiques ou des recommandations de votre électricien.",[5686,22706,22708],{"id":22707},"étape-3-vérifier-la-topologie","Étape 3 : Vérifier la topologie",[17,22710,22711],{},"PlanElec génère automatiquement la topologie des circuits :",[711,22713,22714,22717,22720,22723],{},[714,22715,22716],{},"Les circuits sont regroupés logiquement (éclairage, prises, circuits dédiés)",[714,22718,22719],{},"Chaque circuit reçoit un identifiant unique (ex. : A1, A2, B1, B2)",[714,22721,22722],{},"La hiérarchie de l'interrupteur principal au consommateur final est clairement visible",[714,22724,22725],{},"Les sections de câble sont indiquées pour chaque circuit",[5686,22727,22729],{"id":22728},"étape-4-générer-et-exporter","Étape 4 : Générer et exporter",[17,22731,22732],{},"PlanElec reconstruit le schéma unifilaire à partir des circuits, protections, câbles et récepteurs saisis dans le projet :",[711,22734,22735,22741,22747,22753],{},[714,22736,22737,22740],{},[221,22738,22739],{},"Représentation adaptée au contexte belge"," — Structure lisible du tableau vers les circuits et les récepteurs",[714,22742,22743,22746],{},[221,22744,22745],{},"Catalogue de symboles"," — Symboles électriques pour le contexte de planification belge",[714,22748,22749,22752],{},[221,22750,22751],{},"Étiquetage automatique"," — Références de circuits, types de câbles et valeurs de protection",[714,22754,22755,22757],{},[221,22756,14242],{}," — Sortie documentaire centralisée pour vérification professionnelle",[12,22759,22761],{"id":22760},"exemple-de-schéma-unifilaire-en-pdf","Exemple de schéma unifilaire en PDF",[17,22763,1530,22764,22768],{},[203,22765,22767],{"href":22766},"\u002Fexamples\u002Fdossiers\u002Fplanelec-pilot-dossier-fr.pdf","dossier d'exemple PlanElec"," contient un schéma unifilaire issu d'un projet fictif, accompagné du plan de situation et des autres documents actuellement disponibles. Il montre la structure de l'export réel sans constituer un dossier utilisable pour une installation ou un contrôle.",[17,22770,22771],{},"Utilisez cet exemple pour comprendre la hiérarchie du document, les références de circuits et la relation avec le plan de situation. Pour votre propre projet, toutes les données doivent correspondre à l'installation réelle et être vérifiées professionnellement.",[12,22773,22775],{"id":22774},"erreurs-courantes-à-éviter","Erreurs courantes à éviter",[5686,22777,22779],{"id":22778},"_1-circuits-incomplets","1. Circuits incomplets",[17,22781,22782],{},"Chaque consommateur doit être traçable jusqu'à l'interrupteur principal via une chaîne claire de dispositifs de protection. Ne laissez aucune connexion \"flottante\".",[5686,22784,22786],{"id":22785},"_2-mauvaise-utilisation-des-symboles","2. Mauvaise utilisation des symboles",[17,22788,22789],{},"Utilisez les symboles prescrits pour votre application. Les erreurs courantes incluent d'anciens symboles DIN ou des notations personnelles. Le catalogue PlanElec aide à garder une représentation cohérente ; la responsabilité professionnelle reste celle du créateur.",[5686,22791,22793],{"id":22792},"_3-informations-manquantes","3. Informations manquantes",[17,22795,22796],{},"Chaque circuit doit indiquer :",[711,22798,22799,22802,22805,22808],{},[714,22800,22801],{},"Numéro de référence du circuit",[714,22803,22804],{},"Type et section du câble (ex. : XVB 3G2,5)",[714,22806,22807],{},"Valeur nominale du dispositif de protection (par exemple 16 A ou 20 A ; les tableaux donnent des plafonds et ne remplacent pas le dimensionnement complet)",[714,22809,22810],{},"Nombre et type de consommateurs",[5686,22812,22814],{"id":22813},"_4-schéma-obsolète","4. Schéma obsolète",[17,22816,22817],{},"Si vous avez apporté des modifications à votre installation, le schéma unifilaire doit être mis à jour en conséquence. Un document qui ne correspond plus à l'installation peut entraîner des remarques lors du contrôle.",[12,22819,22821],{"id":22820},"conseils-pour-un-schéma-parfait","Conseils pour un schéma parfait",[711,22823,22824,22830,22836,22842,22848],{},[714,22825,22826,22829],{},[221,22827,22828],{},"Gardez-le propre"," — Évitez les croisements inutiles et les étiquettes qui se chevauchent",[714,22831,22832,22835],{},[221,22833,22834],{},"Soyez cohérent"," — Utilisez le même style de notation dans tout le document",[714,22837,22838,22841],{},[221,22839,22840],{},"Incluez tous les circuits"," — Même les petits ajouts comme une sonnette ou un éclairage de jardin",[714,22843,22844,22847],{},[221,22845,22846],{},"Datez votre document"," — Incluez toujours la date de création\u002Fmodification",[714,22849,22850,22853],{},[221,22851,22852],{},"Ajoutez vos coordonnées"," — Adresse de l'installation et nom du créateur",[12,22855,22857],{"id":22856},"vérifier-systématiquement-les-mentions-requises","Vérifier systématiquement les mentions requises",[17,22859,22860],{},"Pour une installation domestique, le Livre 1 V06 demande notamment le type, la section et le nombre de conducteurs, le mode de pose, le type et les caractéristiques des protections différentielles et contre les surintensités, les interrupteurs, boîtes de connexion et de dérivation, prises, points lumineux, machines et appareils fixes ainsi que les sources telles qu'onduleur ou batterie. Les documents portent aussi numéro, version et date de version. La tension, la nature du courant et l'identification des circuits complètent le contexte.",[17,22862,22863],{},"Une lettre majuscule identifie le circuit élémentaire. Les points lumineux, prises et organes de commande sont numérotés dans l'ordre à partir de la protection contre les surintensités. Le plan de situation réutilise ces références. Un interrupteur renvoie au circuit et au point qu'il commande. C'est cette clé commune qui permet de lire les deux plans ensemble.",[12,22865,22867],{"id":22866},"parcourir-chaque-chaîne-électrique","Parcourir chaque chaîne électrique",[17,22869,22870],{},"Commencez à l'alimentation et suivez chaque branche jusqu'au dernier récepteur. À chaque étape, demandez si le matériel existe réellement, si sa fonction est claire, si le câble est décrit et si la référence spatiale concorde. Les boîtes et ramifications demandent une attention particulière : une simple rangée de symboles ne représente pas correctement une dérivation physique.",[17,22872,22873],{},"Avec plusieurs sources, réseau, onduleur PV et toute alimentation explicitement modélisée doivent rester séparés et compréhensibles. Une icône de batterie ou de borne bidirectionnelle ne prouve pas un flux PlanElec complet publié. Pour le photovoltaïque, l'application peut représenter des chaînes DC structurées et les segments de protection ou câble documentés ; les valeurs inconnues ou non affectées restent signalées comme lacunes.",[12,22875,22877],{"id":22876},"installation-existante-et-modifications","Installation existante et modifications",[17,22879,22880],{},"Une modification ou extension importante impose la création ou l'actualisation du schéma unifilaire et du plan de situation. Pour un changement non important, une description succincte datée et signée peut remplacer un nouveau schéma unifilaire, tandis que le plan spatial reste mis à jour. Les parties antérieures au 1er octobre 1981 sont marquées « partie ancienne ». La Partie 8 prévoit des dérogations ciblées, pas une dispense générale de documentation ou de sécurité.",[12,22882,22884],{"id":22883},"privilégier-la-vérité-électrique","Privilégier la vérité électrique",[17,22886,22887],{},"Une mise en page lisible ne démontre aucun dimensionnement. Section et protection dépendent aussi du mode de pose, du courant admissible, du groupement, de la température, de la chute de tension, du défaut et de la coupure. Même prudence pour type de différentiel, sélectivité, parafoudre et consignes d'appareil. Un symbole personnalisé n'est acceptable que s'il est non ambigu et expliqué dans la légende ; le tableau 2.23 reste le point de départ officiel.",[12,22889,22891],{"id":22890},"source-et-limite","Source et limite",[711,22893,22894,22899],{},[714,22895,22896],{},[203,22897,10017],{"href":5371,"rel":22898},[5373],[714,22900,22901],{},"La section 3.1.2 et le tableau 2.23 encadrent particulièrement le contenu des plans.",[17,22903,22904],{},"PlanElec produit des documents traçables et un auto-contrôle indicatif. Il ne délivre pas de certificat de conformité. Seul l'organisme agréé évalue officiellement l'installation réalisée et le dossier complet.",[12,22906,22908],{"id":22907},"laissez-planelec-faire-le-travail","Laissez PlanElec faire le travail",[17,22910,22911],{},"PlanElec réunit le plan, la topologie électrique et le tableau dans un même projet, puis en déduit le schéma unifilaire.",[711,22913,22914,22917,22920,22923],{},[714,22915,22916],{},"Aucun logiciel CAO nécessaire",[714,22918,22919],{},"Données de projet centralisées sans double saisie",[714,22921,22922],{},"Auto-contrôle RGIE indicatif pour les règles prises en charge et décidables à partir des données",[714,22924,22925],{},"Export PDF du schéma unifilaire et du plan de situation",[17,22927,22928],{},[203,22929,22930],{"href":7861},"Créez votre schéma unifilaire maintenant — c'est gratuit →",[12,22932,1173],{"id":1172},[711,22934,22935,22940,22945,22950],{},[714,22936,22937],{},[203,22938,22939],{"href":1966},"Dessiner un plan de situation selon le RGIE",[714,22941,22942],{},[203,22943,22944],{"href":567},"Planifier un tableau électrique en Belgique",[714,22946,22947],{},[203,22948,22949],{"href":8765},"Documenter une borne de recharge dans le schéma unifilaire",[714,22951,22952],{},[203,22953,22955],{"href":22954},"\u002Ffr\u002Fblog\u002Fchecklist-controle","Préparer les documents du contrôle électrique",{"title":1212,"searchDepth":1213,"depth":1213,"links":22957},[22958,22959,22960,22965,22971,22972,22978,22979,22980,22981,22982,22983,22984,22985],{"id":22492,"depth":1213,"text":22493},{"id":22507,"depth":1213,"text":22508},{"id":22553,"depth":1213,"text":6211,"children":22961},[22962,22963,22964],{"id":22559,"depth":5848,"text":21428},{"id":22585,"depth":5848,"text":1045},{"id":22614,"depth":5848,"text":22615},{"id":22636,"depth":1213,"text":22637,"children":22966},[22967,22968,22969,22970],{"id":22640,"depth":5848,"text":22641},{"id":22672,"depth":5848,"text":22673},{"id":22707,"depth":5848,"text":22708},{"id":22728,"depth":5848,"text":22729},{"id":22760,"depth":1213,"text":22761},{"id":22774,"depth":1213,"text":22775,"children":22973},[22974,22975,22976,22977],{"id":22778,"depth":5848,"text":22779},{"id":22785,"depth":5848,"text":22786},{"id":22792,"depth":5848,"text":22793},{"id":22813,"depth":5848,"text":22814},{"id":22820,"depth":1213,"text":22821},{"id":22856,"depth":1213,"text":22857},{"id":22866,"depth":1213,"text":22867},{"id":22876,"depth":1213,"text":22877},{"id":22883,"depth":1213,"text":22884},{"id":22890,"depth":1213,"text":22891},{"id":22907,"depth":1213,"text":22908},{"id":1172,"depth":1213,"text":1173},"2026-01-05","Découvrez comment réaliser un schéma unifilaire en Belgique : symboles RGIE, informations obligatoires, exemple PDF et génération avec PlanElec.",{},"\u002Fblog\u002Fsingle-line-diagram.fr","14 min",{"title":22479,"description":22987},"blog\u002Fsingle-line-diagram.fr",[1243,1242,1248,20666,20671,20672,18547,22994,10095,20668,10265,20868,8422,1249],"IEC 60617","lQFm5SBN4dfq0-Vo_2_lHkIdkprZx9yBU2TKBysoC3w",{"id":22997,"title":22998,"articleId":22999,"body":23000,"category":23205,"date":23206,"description":23207,"extension":1231,"lastUpdated":5432,"locale":1232,"meta":23208,"navigation":1234,"path":23209,"publishDate":22097,"readTime":4995,"refreshInterval":7920,"seo":23210,"slug":23211,"stem":23212,"tags":23213,"__hash__":23218},"blog\u002Fblog\u002Farei-regulations-2026.fr.md","Réglementation RGIE 2026 : Les Changements Clés","arei-regulations-2026",{"type":9,"value":23001,"toc":23191},[23002,23006,23013,23029,23032,23036,23039,23042,23062,23065,23069,23073,23076,23083,23087,23090,23094,23097,23101,23104,23111,23114,23131,23135,23138,23141,23145,23148,23154,23160,23166,23170,23173,23179,23183,23186],[12,23003,23005],{"id":23004},"ce-qui-sapplique-depuis-le-1er-avril-2026","Ce qui s'applique depuis le 1er avril 2026",[17,23007,23008,23009,23012],{},"Le RGIE — AREI en néerlandais — se compose de trois livres. Le Livre 1 est la référence principale pour les installations domestiques à basse tension. Une nouvelle version coordonnée de ce livre s'applique depuis le ",[221,23010,23011],{},"1er avril 2026",". Elle intègre l'arrêté royal du 6 octobre 2025, publié le 29 octobre 2025. Un erratum du 5 novembre a corrigé la présentation de la publication sans modifier son contenu.",[17,23014,23015,23016,23019,23020,23024,23025,212],{},"La portée officielle est plus ciblée que ne le laissent entendre de nombreux résumés. La modification intègre les ",[221,23017,23018],{},"schémas mis à la terre en courant continu"," dans le règlement. Elle décrit les variantes DC des schémas TN, TT et IT, les relie aux protections contre les contacts indirects et adapte des définitions et renvois du Livre 1. Le SPF Economie expose cette portée sur sa ",[203,23021,23023],{"href":5371,"rel":23022},[5373],"page officielle du RGIE en vigueur",", où il publie aussi le ",[203,23026,23028],{"href":13789,"rel":23027},[5373],"Livre 1 coordonné pour 2026",[17,23030,23031],{},"Il ne s'agit donc pas d'une réécriture générale de toutes les règles domestiques. Les circuits de recharge, les volumes de salle de bains, les documents photovoltaïques ou les périodicités de contrôle restent importants, mais ne sont pas automatiquement des « nouveautés 2026 ». La date d'exécution, la nature des travaux et le chapitre applicable du texte coordonné déterminent la règle pertinente.",[12,23033,23035],{"id":23034},"la-modification-de-fond-une-place-structurée-pour-le-courant-continu","La modification de fond : une place structurée pour le courant continu",[17,23037,23038],{},"Le photovoltaïque, les batteries, les distributions DC et les appareils capables de réinjecter de l'énergie rendent insuffisante une lecture exclusivement AC du bâtiment. Le texte 2026 étend donc les classifications usuelles aux schémas DC mis à la terre. Les lettres TN, TT et IT décrivent toujours le rapport entre conducteurs actifs, terre et masses accessibles, mais la mesure de protection doit correspondre à la source continue, à la mise à la terre et au comportement de coupure.",[17,23040,23041],{},"Cela ne signifie pas que chaque logement doit recevoir un réseau DC. Cela signifie qu'une partie continue qui dépasse le câblage interne ordinaire d'un équipement, ou qui constitue une distribution mise à la terre, ne peut pas être documentée comme un simple départ AC. L'auteur de l'étude doit au minimum déterminer :",[711,23043,23044,23047,23050,23053,23056,23059],{},[714,23045,23046],{},"où commence et où se termine la partie DC ;",[714,23048,23049],{},"si elle est isolée de la terre ou volontairement mise à la terre, et en quel point ;",[714,23051,23052],{},"quels conducteurs actifs sont commandés et sectionnés ;",[714,23054,23055],{},"quelle mesure réagit à un défaut d'isolement ;",[714,23057,23058],{},"quelles conditions de coupure correspondent au schéma TN, TT ou IT choisi ;",[714,23060,23061],{},"quelles limites du fabricant encadrent tension, polarité, protections et cheminement.",[17,23063,23064],{},"Ces réponses dépendent du projet. Le mot « batterie » ou « PV » n'impose ni un schéma de terre unique ni une protection universelle. Le dimensionnement relève d'un professionnel qualifié, puis l'organisme agréé évalue l'installation terminée au regard du texte applicable et des preuves fournies.",[12,23066,23068],{"id":23067},"ce-quil-ne-faut-pas-présenter-comme-une-nouvelle-obligation-2026","Ce qu'il ne faut pas présenter comme une nouvelle obligation 2026",[5686,23070,23072],{"id":23071},"recharge-des-véhicules","Recharge des véhicules",[17,23074,23075],{},"Le chapitre spécial 7.22 relatif aux bornes conductives existait avant 2026. Il impose notamment un circuit terminal dédié à chaque point de connexion, une protection différentielle complémentaire individuelle de 30 mA au plus pour chaque circuit AC et une protection contre les composantes continues lisses du courant de défaut. La solution peut associer un différentiel de type B, un type A avec détection DC appropriée ou une autre combinaison conforme ; elle dépend de la borne et de toute la chaîne de protection. La notice du fabricant reste indispensable.",[17,23077,23078,23079,212],{},"Les bornes bidirectionnelles, ou techniquement capables de l'être, ajoutent une question de raccordement au réseau. Synergrid indique qu'elles relèvent de C10\u002F11 édition 2.4 et nécessitent une homologation C10\u002F26. Les chargeurs strictement unidirectionnels, du réseau vers le véhicule, ne nécessitent pas une homologation C10\u002F26 du seul fait qu'ils rechargent une voiture. Cette distinction figure sur la ",[203,23080,23082],{"href":6589,"rel":23081},[5373],"page Synergrid des unités de production décentralisée",[5686,23084,23086],{"id":23085},"salles-de-bains","Salles de bains",[17,23088,23089],{},"Les salles de bains et de douches restent des emplacements spéciaux. Les volumes, indices IP, matériels admis et protections différentielles doivent être vérifiés dans le chapitre 7.1 de la version coordonnée. La présentation officielle de la modification 2026 ne justifie pas l'affirmation générale d'un « nouveau volume 3 ». De même, IPX5 n'est pas une exigence inconditionnelle pour le volume 1 : le degré de protection dépend notamment de l'emploi éventuel de jets d'eau pour le nettoyage. Il faut relever la géométrie réelle et la sortie d'eau fixe, plutôt que reproduire un dessin simplifié trouvé en ligne.",[5686,23091,23093],{"id":23092},"surtensions-pv-et-documents-numériques","Surtensions, PV et documents numériques",[17,23095,23096],{},"La protection contre les surtensions, la conception des protections PV et les documents électroniques ne forment pas davantage un paquet de nouvelles obligations 2026. Le Livre 1 contient des principes dont l'application dépend de l'installation, du risque, du matériel et de la date d'exécution. La transmission électronique d'un rapport de contrôle n'est pas, en elle-même, une nouvelle mesure de protection électrique. Le texte en vigueur, les preuves du fabricant et l'analyse professionnelle restent déterminants.",[12,23098,23100],{"id":23099},"comment-déterminer-les-règles-applicables-à-lexistant","Comment déterminer les règles applicables à l'existant",[17,23102,23103],{},"La question utile n'est pas seulement « Quel âge a le bâtiment ? », mais « Quand chaque partie a-t-elle été réalisée et quels travaux sont entrepris maintenant ? ». Certaines parties existantes peuvent relever de dérogations, tandis qu'un nouveau circuit doit satisfaire aux exigences actuelles. Une modification ou extension importante requiert un contrôle de conformité avant mise en usage ; le contrôle vise les travaux et leurs effets possibles sur la partie inchangée.",[17,23105,1759,23106,23110],{},[203,23107,23109],{"href":6185,"rel":23108},[5373],"page officielle sur le contrôle des installations domestiques"," cite les principaux cas : avant mise en usage, après modification ou extension importante, pour certains renforcements de puissance, lors de la vente d'une unité d'habitation et périodiquement. Elle donne l'ajout d'une prise sur un circuit existant comme exemple d'extension non importante. La qualification finale dépend néanmoins de la portée réelle des travaux.",[17,23112,23113],{},"Un dossier de rénovation devrait donc conserver une liste claire des modifications :",[5034,23115,23116,23119,23122,23125,23128],{},[714,23117,23118],{},"relever l'existant et sa période d'exécution connue ou estimée ;",[714,23120,23121],{},"distinguer les parties neuves et inchangées sur les plans ;",[714,23123,23124],{},"analyser l'effet d'une nouvelle source, batterie ou borne sur le tableau et les protections ;",[714,23126,23127],{},"lever les hypothèses avec l'électricien et l'organisme agréé ;",[714,23129,23130],{},"mettre à jour le schéma unifilaire et le plan de situation après les travaux.",[12,23132,23134],{"id":23133},"ce-que-doit-contenir-le-dossier-présenté-au-contrôle","Ce que doit contenir le dossier présenté au contrôle",[17,23136,23137],{},"Pour un contrôle domestique, le SPF Economie demande au minimum les schémas unifilaires, les plans de situation et, s'il est disponible, le code EAN du raccordement. Le schéma unifilaire décrit les circuits, leurs interconnexions et les caractéristiques du matériel. Le plan de situation localise tableaux, boîtes de connexion et de dérivation, prises, points lumineux, interrupteurs, machines fixes et sources. Ces plans font partie du dossier avec les rapports de contrôle, les descriptions succinctes des modifications non importantes et les documents techniques, notamment ceux du photovoltaïque.",[17,23139,23140],{},"Pour une distribution DC, une documentation utile ne se limite pas au nom de l'appareil. Elle précise les références des sources et câbles, tensions assignées, polarité, points de sectionnement, dispositifs de protection, concept de mise à la terre et document fabricant associé. Un schéma lisible ne remplace ni calculs ni mesures, mais permet au propriétaire, à l'installateur et au contrôleur de parler de la même installation.",[12,23142,23144],{"id":23143},"une-méthode-de-vérification-pour-un-projet-en-2026","Une méthode de vérification pour un projet en 2026",[17,23146,23147],{},"Procédez en trois étapes avant la commande ou la pose.",[17,23149,23150,23153],{},[221,23151,23152],{},"Confirmer la version réglementaire."," Utilisez l'édition coordonnée applicable à la date prévue des travaux. Un article de blog sert d'orientation et non de source juridique. En cas de doute, la publication du SPF Economie et ses interprétations officielles priment.",[17,23155,23156,23159],{},[221,23157,23158],{},"Déterminer le champ d'application."," Notez s'il s'agit d'une installation neuve, d'une extension importante, d'une petite modification, d'une vente, d'un contrôle périodique ou d'un renforcement. Pour une borne, définissez aussi le sens du flux d'énergie : la capacité bidirectionnelle peut déclencher des obligations réseau absentes d'un chargeur unidirectionnel.",[17,23161,23162,23165],{},[221,23163,23164],{},"Rassembler les preuves."," Conservez le choix des câbles et protections, les notices, les mesures et les plans. Pour les composants DC, les fiches doivent traiter de la mise à la terre admise, du comportement aux courants de défaut et du sectionnement. Sans ces données, un dessin visuellement complet ne constitue pas encore une justification technique complète.",[12,23167,23169],{"id":23168},"ce-que-planelec-apporte-et-ses-limites","Ce que PlanElec apporte, et ses limites",[17,23171,23172],{},"PlanElec accompagne le parcours du plan d'étage et de la topologie électrique vers le schéma unifilaire, le plan de situation et l'export PDF. Son autocontrôle assisté par logiciel signale des problèmes pris en charge et déductibles des données saisies. Il ne constitue pas une attestation de conformité et ne remplace ni mesures, ni documents fabricant, ni conditions sur site.",[17,23174,23175,23176,23178],{},"Le texte réglementaire complet documenté correspond au Livre 1 V06, applicable depuis le ",[221,23177,23011],{},". La validation du produit n'en traduit toutefois qu'un sous-ensemble documenté en règles automatisées. Les schémas DC TN, TT et IT mis à la terre, les rôles de leurs conducteurs et la logique de protection associée ne sont notamment pas encore modélisés dans leur totalité. Un tel projet exige donc une étude professionnelle, les preuves du matériel et le contrôle officiel. PlanElec aide à structurer des informations cohérentes ; seul un organisme agréé rend l'appréciation officielle.",[12,23180,23182],{"id":23181},"en-résumé","En résumé",[17,23184,23185],{},"La nouveauté 2026 vérifiable est l'intégration systématique des schémas DC mis à la terre dans le Livre 1. Elle n'impose pas une rénovation générale de chaque logement existant et ne crée pas un paquet unique de nouvelles obligations pour bornes, salles de bains, SPD et documents numériques. Qualifiez d'abord les travaux, consultez le texte officiel actuel et documentez clairement les parties AC et DC. Vous fournissez ainsi une base solide à l'électricien et au contrôleur sans anticiper le résultat du contrôle.",[17,23187,23188],{},[203,23189,23190],{"href":7861},"Structurer votre documentation électrique avec PlanElec →",{"title":1212,"searchDepth":1213,"depth":1213,"links":23192},[23193,23194,23195,23200,23201,23202,23203,23204],{"id":23004,"depth":1213,"text":23005},{"id":23034,"depth":1213,"text":23035},{"id":23067,"depth":1213,"text":23068,"children":23196},[23197,23198,23199],{"id":23071,"depth":5848,"text":23072},{"id":23085,"depth":5848,"text":23086},{"id":23092,"depth":5848,"text":23093},{"id":23099,"depth":1213,"text":23100},{"id":23133,"depth":1213,"text":23134},{"id":23143,"depth":1213,"text":23144},{"id":23168,"depth":1213,"text":23169},{"id":23181,"depth":1213,"text":23182},"news","2026-01-02","Ce qui a réellement changé dans le RGIE au 1er avril 2026 et comment en mesurer les effets sur l'étude, le dossier et le contrôle.",{},"\u002Fblog\u002Farei-regulations-2026.fr",{"title":22998,"description":23207},"reglementations-rgie-2026","blog\u002Farei-regulations-2026.fr",[1243,1242,23214,23215,23216,10095,1248,8422,9283,23217,1249],"réglementation 2026","réglementations électriques","courant continu","photovoltaïque","oGYLqia3bZYZFLt2kW3wU3YYxFm41FM5waVXonObHwM",1788389230121]