[{"data":1,"prerenderedAt":2244},["ShallowReactive",2],{"blog-post-en-inspection-failed-what-now":3,"blog-alternates-inspection-failed-what-now":499},{"id":4,"title":5,"articleId":6,"body":7,"category":477,"date":478,"description":479,"extension":480,"lastUpdated":481,"locale":482,"meta":483,"navigation":484,"path":485,"publishDate":478,"readTime":486,"refreshInterval":487,"seo":488,"slug":6,"stem":489,"tags":490,"__hash__":498},"blog\u002Fblog\u002Finspection-failed-what-now.en.md","Electrical Inspection Failed — What Now? Step-by-Step Guide After a Negative Inspection","inspection-failed-what-now",{"type":8,"value":9,"toc":448},"minimark",[10,18,21,26,33,38,90,93,97,101,108,112,115,119,126,130,133,167,170,173,177,181,184,196,200,203,207,214,228,232,239,243,246,250,253,257,260,283,287,290,293,310,313,317,320,323,327,330,333,337,340,344,367,370,374,380,406,409,412,417,437],[11,12,13,17],"p",{},[14,15,16],"strong",{},"Work methodically."," The official sources used here do not publish a dependable national failure percentage. A negative report also does not tell you, in the abstract, whether it concerns documentation or an immediate safety risk. The individual findings in the inspection body's report are decisive.",[11,19,20],{},"In this guide, you'll learn what to do after a negative inspection, what the deficiency codes mean and how to prepare for the re-inspection.",[22,23,25],"h2",{"id":24},"what-happens-after-a-negative-inspection","What Happens After a Negative Inspection?",[11,27,28,29,32],{},"After the inspection, you receive a ",[14,30,31],{},"detailed report"," from the approved inspection body. It lists the infringements, affected installation sections and conclusion.",[34,35,37],"h3",{"id":36},"read-codes-using-the-reports-own-legend","Read codes using the report's own legend",[39,40,41,54],"table",{},[42,43,44],"thead",{},[45,46,47,51],"tr",{},[48,49,50],"th",{},"Report field",[48,52,53],{},"What to derive from it",[55,56,57,66,74,82],"tbody",{},[45,58,59,63],{},[60,61,62],"td",{},"Code or category",[60,64,65],{},"Meaning from this report's own legend only",[45,67,68,71],{},[60,69,70],{},"Rule reference",[60,72,73],{},"Provision and protective function being challenged",[45,75,76,79],{},[60,77,78],{},"Location or circuit",[60,80,81],{},"Unambiguous affected installation section",[45,83,84,87],{},[60,85,86],{},"Conclusion and deadline",[60,88,89],{},"Consequence of the actual control type, not a generic short code",[11,91,92],{},"Code systems and priority classes can vary between organisations and report templates. Do not derive a universal Belgian deadline from “C1”, “C2” or “C3”. Use the legend in the actual report and ask the issuer to clarify the rule reference, circuit and expected proof. Any finding identified as immediate danger takes priority regardless of its short code.",[22,94,96],{"id":95},"deadlines-by-situation","Deadlines by Situation",[34,98,100],{"id":99},"property-sale","Property Sale",[11,102,103,104,107],{},"For the relevant sale inspection of an old dwelling, the buyer generally has ",[14,105,106],{},"18 months from the authentic deed",", not simply a private offer date, to remedy the installation and arrange a new inspection.",[34,109,111],{"id":110},"new-installation","New Installation",[11,113,114],{},"For a new installation or major modification, the section affected by infringements cannot be put into use. The issues must first be corrected and a new conformity control carried out. Any grid-connection process must be confirmed separately with the relevant operator.",[34,116,118],{"id":117},"periodic-inspection","Periodic Inspection",[11,120,121,122,125],{},"After a negative periodic inspection, federal guidance requires a supplementary visit by the ",[14,123,124],{},"same body within twelve months",". Still verify the control type, report and any special instruction.",[22,127,129],{"id":128},"ten-review-areas-not-a-statistical-ranking","Ten review areas, not a statistical ranking",[11,131,132],{},"Use these as review areas, not a claim about national frequency or an automatic verdict:",[134,135,136,140,143,146,149,152,155,158,161,164],"ol",{},[137,138,139],"li",{},"residual-current protection appropriate to each circuit and load;",[137,141,142],{},"single-line diagram, situation plan and board labels describing the same installation;",[137,144,145],{},"earthing, bonding and automatic-disconnection concept supported by measurements;",[137,147,148],{},"clear identification of circuits and protective devices;",[137,150,151],{},"cable selection and mechanical protection appropriate to the installation method;",[137,153,154],{},"special-location rules, including the actual bathroom geometry;",[137,156,157],{},"main switching and isolation suitable for the installation;",[137,159,160],{},"coordination of conductor, installation conditions and overcurrent protection;",[137,162,163],{},"an explicit project assessment of surge protection;",[137,165,166],{},"separation of AREI\u002FRGIE findings from regional housing duties such as smoke alarms.",[11,168,169],{},"The inspector's exact finding and the current Book 1 text determine what must be corrected. A list cannot replace diagnosis, measurements or the report.",[11,171,172],{},"Record the applicable edition and the inspector's wording before choosing a remedy.",[22,174,176],{"id":175},"step-by-step-after-the-negative-inspection","Step by Step: After the Negative Inspection",[34,178,180],{"id":179},"step-1-read-the-report-carefully","Step 1: Read the Report Carefully",[11,182,183],{},"Go through each deficiency individually. Note down:",[185,186,187,190,193],"ul",{},[137,188,189],{},"Which report category and legend does the inspection body use?",[137,191,192],{},"Where exactly is the problem (room, circuit)?",[137,194,195],{},"What exactly is the complaint?",[34,197,199],{"id":198},"step-2-set-priorities","Step 2: Set Priorities",[11,201,202],{},"Start with every item the report identifies as immediate danger, a reason for disconnection, or a barrier to first use. Then order the remaining work by dependency: cause and protection concept first, followed by execution, measurement and documentation.",[34,204,206],{"id":205},"step-3-professional-or-diy","Step 3: Professional or DIY?",[11,208,209,210,213],{},"You can organise the report, collect records and compare the drawings with visible equipment. Whether a correction is safe and lawful to carry out yourself depends on the work and your competence. Work inside a distribution board or on protection, earthing and fixed wiring belongs with an ",[14,211,212],{},"electrical professional",":",[185,215,216,219,222,225],{},[137,217,218],{},"Retrofit or replace RCDs",[137,220,221],{},"Improve earthing",[137,223,224],{},"Route cables through protective conduit",[137,226,227],{},"Install the main switch",[34,229,231],{"id":230},"step-4-update-plans","Step 4: Update Plans",[11,233,234,235,238],{},"The single-line diagram and situation plan must reflect the ",[14,236,237],{},"current state",". Do not invent conductor sizes or protection ratings. Resolve unknown characteristics before export or record them clearly as open.",[34,240,242],{"id":241},"step-5-schedule-the-re-inspection","Step 5: Schedule the Re-Inspection",[11,244,245],{},"The responsible body depends on the procedure. A supplementary visit after a negative periodic inspection is carried out by the same body. For a new inspection after the relevant negative sale inspection, the buyer may generally select an approved body and the complete installation is reviewed again. Confirm the scope from the report before booking.",[22,247,249],{"id":248},"budget-without-false-precision","Budget without false precision",[11,251,252],{},"Fees and repair costs vary with procedure, inspection body, travel, number of boards, measurement effort and the actual defect. Request the current tariff directly. A repair quotation should separate diagnosis, materials, labour, measurements, drawing updates and the next inspection. A fixed online price cannot represent concealed wiring repairs or a board rebuild.",[22,254,256],{"id":255},"build-evidence-for-the-next-inspection","Build evidence for the next inspection",[11,258,259],{},"Keep one row per finding: report text, affected circuit, planned action, responsible person, completion date and evidence. Photos can support the record but do not replace measurements. Update drawings only after the work has actually been completed, then reconcile labels and references again.",[11,261,262,263,270,271,276,277,282],{},"The official ",[264,265,269],"a",{"href":266,"rel":267},"https:\u002F\u002Feconomie.fgov.be\u002Ffr\u002Fthemes\u002Fenergie\u002Fsources-et-vecteurs-denergie\u002Felectricite\u002Fsecurite-et-controle-des\u002Fcontrole-des-installations\u002Ftypes-de-controle-des",[268],"nofollow","domestic inspection-types page"," explains consequences and deadlines. The ",[264,272,275],{"href":273,"rel":274},"https:\u002F\u002Feconomie.fgov.be\u002Ffr\u002Fthemes\u002Fenergie\u002Fsources-et-vecteurs-denergie\u002Felectricite\u002Fsecurite-et-controle-des\u002Flivre-1-du-reglement-general",[268],"federal property-sale FAQ"," covers the 18-month period and selection of an inspection body. Use the federal ",[264,278,281],{"href":279,"rel":280},"https:\u002F\u002Feconomie.fgov.be\u002Ffr\u002Fthemes\u002Fenergie\u002Fsources-et-vecteurs-denergie\u002Felectricite\u002Fsecurite-et-controle-des\u002Forganismes-de-controle-agrees",[268],"list of approved bodies"," when booking.",[22,284,286],{"id":285},"turn-each-finding-into-a-verifiable-action","Turn each finding into a verifiable action",[11,288,289],{},"An inspection report often states an outcome rather than the technical cause. Low insulation resistance might come from a damaged conductor, moisture, connected equipment or several issues together. “Drawing does not match” can mean a missing socket or an incorrect sequence of protective devices. Do not immediately order one component; first establish the cause and affected scope.",[11,291,292],{},"Ask five questions for every finding:",[134,294,295,298,301,304,307],{},[137,296,297],{},"which installation section was actually inspected?",[137,299,300],{},"which rule or protective function is affected?",[137,302,303],{},"what diagnosis or measurement confirms the cause?",[137,305,306],{},"what correction removes the cause instead of hiding the symptom?",[137,308,309],{},"what evidence will allow the inspection body to verify the completed correction?",[11,311,312],{},"Findings can depend on one another. A board alteration changes the single-line diagram, labels, protective devices and potentially measurements. Earthing work must be complete before the final drawings and repeat measurements. Plan one consistent final state instead of documenting a chain of contradictory intermediate states.",[22,314,316],{"id":315},"separate-documentation-from-physical-defects","Separate documentation from physical defects",[11,318,319],{},"A missing drawing is not solved by drawing unverified assumptions. Survey the installation first; opening and measuring equipment belongs only with someone able to do so safely and competently. Then connect every plan symbol to the actual circuit and confirm that the board, single-line diagram and situation plan use the same reference.",[11,321,322],{},"A physical defect is not solved by improving the drawing. If a protective device is unsuitable, earthing inadequate or a cable mechanically exposed, the physical installation must be corrected and, where required, measured again. Only then should the drawings be updated to the executed condition. This order prevents a return visit from finding current documents but the same hazard.",[22,324,326],{"id":325},"the-property-sale-case","The property-sale case",[11,328,329],{},"After a negative sale inspection, keep the report, authentic deed and installation file together. The eighteen months run from the authentic deed. The buyer communicates identity and deed date to the original inspection body. If another approved body is chosen for the new visit, the official federal explanation says that body informs the first one.",[11,331,332],{},"The period is not permission to ignore an evident hazard. Have unsafe sections assessed promptly and isolated where necessary. A resale, complete renovation or demolition during the period may change the procedure; use the federal FAQ and the specific notarial situation rather than a generic answer.",[22,334,336],{"id":335},"control-changes-before-the-follow-up-visit","Control changes before the follow-up visit",[11,338,339],{},"After remediation, freeze a documented state: dated plans, board labels, measurement records and photographs of work that will become concealed. Compare every later change with that state and update the file where necessary. Otherwise, one seemingly minor added cable can break the consistency that the electrician and drafter established. Ask all users to avoid temporary connections and independent alterations before the visit. If a change is unavoidable, give the responsible professional the report, current plans and an exact description of the new work. The evidence then remains continuous and the inspector does not unknowingly assess a different installation from the one prepared.",[22,341,343],{"id":342},"final-readiness-check","Final readiness check",[185,345,346,349,352,355,358,361,364],{},[137,347,348],{},"Every finding maps to a completed action.",[137,350,351],{},"Corrections requiring measurements have documented results.",[137,353,354],{},"Circuit references match at the board and on both plans.",[137,356,357],{},"Added and removed equipment is reflected on the situation plan.",[137,359,360],{},"Ratings and cable data match the executed single-line diagram.",[137,362,363],{},"The correct body and inspection type are confirmed.",[137,365,366],{},"Report, drawings, EAN code and relevant manufacturer evidence are ready.",[11,368,369],{},"This cannot promise a positive report. It does prevent a completed repair from becoming unverifiable because records or references contradict one another.",[22,371,373],{"id":372},"how-planelec-helps","How PlanElec Helps",[11,375,376,377,213],{},"The PlanElec self-check can flag some supported planning issues ",[14,378,379],{},"before the inspection",[185,381,382,388,394,400],{},[137,383,384,387],{},[14,385,386],{},"Validation"," flags supported data about RCDs and protection sizing",[137,389,390,393],{},[14,391,392],{},"Single-line diagram"," represents the entered topology consistently",[137,395,396,399],{},[14,397,398],{},"Situation plan"," uses the supported Belgian symbol library",[137,401,402,405],{},[14,403,404],{},"Labelling"," of all circuits is automatically documented in the diagram",[11,407,408],{},"The self-check is not a conformity certificate, performs no measurements and cannot guarantee a positive result. It supports a consistent file for professional review.",[410,411],"hr",{},[11,413,414],{},[14,415,416],{},"Related articles:",[185,418,419,425,431],{},[137,420,421],{},[264,422,424],{"href":423},"\u002Fen\u002Fblog\u002Ftop-10-arei-violations","Top 10 AREI Violations",[137,426,427],{},[264,428,430],{"href":429},"\u002Fen\u002Fblog\u002F30ma-rcd-per-socket","30 mA RCD: When Is It Mandatory?",[137,432,433],{},[264,434,436],{"href":435},"\u002Fen\u002Fblog\u002Fcable-cross-section-breaker","Cable Cross-Section and Breaker: The Right Combination",[11,438,439,442,443],{},[14,440,441],{},"Prepare your electrical plans with PlanElec and use the self-check as guidance before professional review and the official inspection."," ",[264,444,447],{"href":445,"rel":446},"https:\u002F\u002Fplanelec.be",[268],"Get started →",{"title":449,"searchDepth":450,"depth":450,"links":451},"",2,[452,456,461,462,469,470,471,472,473,474,475,476],{"id":24,"depth":450,"text":25,"children":453},[454],{"id":36,"depth":455,"text":37},3,{"id":95,"depth":450,"text":96,"children":457},[458,459,460],{"id":99,"depth":455,"text":100},{"id":110,"depth":455,"text":111},{"id":117,"depth":455,"text":118},{"id":128,"depth":450,"text":129},{"id":175,"depth":450,"text":176,"children":463},[464,465,466,467,468],{"id":179,"depth":455,"text":180},{"id":198,"depth":455,"text":199},{"id":205,"depth":455,"text":206},{"id":230,"depth":455,"text":231},{"id":241,"depth":455,"text":242},{"id":248,"depth":450,"text":249},{"id":255,"depth":450,"text":256},{"id":285,"depth":450,"text":286},{"id":315,"depth":450,"text":316},{"id":325,"depth":450,"text":326},{"id":335,"depth":450,"text":336},{"id":342,"depth":450,"text":343},{"id":372,"depth":450,"text":373},"guide","2026-06-16","Your electrical inspection came back negative? Learn how to read the report, identify the applicable deadline, plan safe corrections and prepare the next inspection.","md","2026-08-29","en",{},true,"\u002Fblog\u002Finspection-failed-what-now.en","6 min",12,{"title":5,"description":479},"blog\u002Finspection-failed-what-now.en",[491,492,493,494,495,496,497],"inspection","electrical-inspection","failed","deficiencies","re-inspection","arei","belgium","7jZl0H6vyH4U2qw0McO_s2xf1uoYREMPn4MLk15YcAs",[500,1006,1310,1771],{"id":501,"title":502,"articleId":6,"body":503,"category":477,"date":478,"description":991,"extension":480,"lastUpdated":481,"locale":992,"meta":993,"navigation":484,"path":994,"publishDate":478,"readTime":486,"refreshInterval":487,"seo":995,"slug":996,"stem":997,"tags":998,"__hash__":1005},"blog\u002Fblog\u002Finspection-failed-what-now.de.md","Elektrokontrolle durchgefallen — was nun? Schritt-für-Schritt-Anleitung nach einer negativen Elektrokontrolle",{"type":8,"value":504,"toc":965},[505,511,514,518,525,529,532,536,540,547,551,554,558,565,569,696,700,704,707,718,722,725,729,735,749,753,760,764,767,771,774,778,781,799,803,806,809,826,829,833,836,839,843,846,849,853,856,860,883,886,889,893,900,926,929,931,936,956],[11,506,507,510],{},[14,508,509],{},"Bleiben Sie systematisch."," Eine belastbare landesweite Quote negativer Elektrokontrollen ist in den hier verwendeten offiziellen Quellen nicht veröffentlicht. Aus einem negativen Bericht lässt sich auch nicht pauschal ableiten, ob nur Dokumentation fehlt oder ein Sicherheitsrisiko besteht. Maßgeblich sind die einzelnen Feststellungen des Kontrollorganismus.",[11,512,513],{},"In diesem Guide erfahren Sie, was nach einer negativen Kontrolle zu tun ist, welche Mängelcodes es gibt und wie Sie sich auf die Nachkontrolle vorbereiten.",[22,515,517],{"id":516},"was-passiert-nach-einer-negativen-kontrolle","Was passiert nach einer negativen Kontrolle?",[11,519,520,521,524],{},"Nach der Kontrolle erhalten Sie einen ",[14,522,523],{},"ausführlichen Bericht"," des zugelassenen Kontrollorganismus. Er nennt die festgestellten Verstöße, betroffene Anlagenteile und die Schlussfolgerung.",[34,526,528],{"id":527},"mängelcodes-richtig-lesen","Mängelcodes richtig lesen",[11,530,531],{},"Interne Kürzel und Prioritätsklassen können zwischen Organismen und Berichtsvorlagen variieren. Leiten Sie aus „C1“, „C2“ oder „C3“ daher keine allgemeingültige belgische Frist ab. Lesen Sie die Legende des konkreten Berichts. Bei unklarer Beschreibung bitten Sie den Aussteller schriftlich um die genaue Fundstelle, den betroffenen Stromkreis und die erwartete Nachweisform. Hinweise auf unmittelbare Gefahr haben unabhängig vom Kürzel Vorrang; schalten Sie den betroffenen Teil nicht eigenmächtig wieder ein.",[22,533,535],{"id":534},"fristen-je-nach-situation","Fristen je nach Situation",[34,537,539],{"id":538},"bei-immobilienverkauf","Bei Immobilienverkauf",[11,541,542,543,546],{},"Bei der einschlägigen Verkaufskontrolle einer alten Wohneinheit hat der Käufer grundsätzlich ",[14,544,545],{},"18 Monate ab dem Datum der authentischen Urkunde",", um die Anlage in Ordnung zu bringen und eine neue Kontrolle durchführen zu lassen. Das ist nicht einfach das Datum eines privaten Kaufversprechens.",[34,548,550],{"id":549},"bei-neuinstallation","Bei Neuinstallation",[11,552,553],{},"Bei einer neuen Installation oder wichtigen Änderung darf der von Verstößen betroffene Teil nicht in Gebrauch genommen werden. Zuerst werden die Verstöße behoben, danach erfolgt eine neue Konformitätskontrolle. Netzanschlussprozesse sind zusätzlich mit dem zuständigen Netzbetreiber zu klären.",[34,555,557],{"id":556},"bei-periodischer-kontrolle","Bei periodischer Kontrolle",[11,559,560,561,564],{},"Nach einer negativen periodischen Kontrolle sieht die offizielle Information eine ergänzende Kontrolle durch ",[14,562,563],{},"denselben Organismus innerhalb von zwölf Monaten"," vor. Prüfen Sie dennoch Kontrollart, Bericht und eventuelle besondere Anweisung.",[22,566,568],{"id":567},"zehn-prüfbereiche-statt-unbelegter-rangliste","Zehn Prüfbereiche statt unbelegter Rangliste",[39,570,571,584],{},[42,572,573],{},[45,574,575,578,581],{},[48,576,577],{},"Nr.",[48,579,580],{},"Zu prüfender Bereich",[48,582,583],{},"Bezug",[55,585,586,597,608,619,630,641,652,663,674,685],{},[45,587,588,591,594],{},[60,589,590],{},"1",[60,592,593],{},"Fehlender oder ungeeigneter FI-Schutz; Empfindlichkeit und Typ müssen zum Stromkreis passen",[60,595,596],{},"Buch 1, Schutz gegen elektrischen Schlag",[45,598,599,602,605],{},[60,600,601],{},"2",[60,603,604],{},"Fehlende oder veraltete Elektropläne; Eindrahtschema, Situationsplan und Anlage müssen übereinstimmen",[60,606,607],{},"Buch 1, Installationsdossier",[45,609,610,613,616],{},[60,611,612],{},"3",[60,614,615],{},"Erdung und Fehlerstromschutz passen nicht zusammen; ein einzelner Messwert ist ohne Schutzkonzept nicht ausreichend",[60,617,618],{},"Buch 1, Erdung und automatische Abschaltung",[45,620,621,624,627],{},[60,622,623],{},"4",[60,625,626],{},"Stromkreise sind nicht eindeutig beschriftet",[60,628,629],{},"Kennzeichnung und Dossier",[45,631,632,635,638],{},[60,633,634],{},"5",[60,636,637],{},"Leitungen sind für Typ und Verlegeart nicht ausreichend mechanisch geschützt",[60,639,640],{},"Auswahl und Verlegung von Leitungen",[45,642,643,646,649],{},[60,644,645],{},"6",[60,647,648],{},"Volumen und Schutzanforderungen im Bad wurden nicht eingehalten",[60,650,651],{},"Kapitel 7.1",[45,653,654,657,660],{},[60,655,656],{},"7",[60,658,659],{},"Hauptschalt- oder Trenneinrichtung entspricht nicht der konkreten Anlage",[60,661,662],{},"Buch 1, häusliche Anlagen",[45,664,665,668,671],{},[60,666,667],{},"8",[60,669,670],{},"Schutzgerät, Querschnitt und Verlegebedingungen sind nicht koordiniert",[60,672,673],{},"Überstromschutz",[45,675,676,679,682],{},[60,677,678],{},"9",[60,680,681],{},"Überspannungsrisiko und gegebenenfalls SPD-Ausführung wurden nicht fachlich bewertet",[60,683,684],{},"Schutz gegen Überspannungen",[45,686,687,690,693],{},[60,688,689],{},"10",[60,691,692],{},"Regionale Rauchmelderpflicht wird mit AREI-Dokumentationspflicht vermischt; beide Rechtsbereiche getrennt prüfen",[60,694,695],{},"Regionales Wohnrecht, nicht pauschal AREI",[22,697,699],{"id":698},"schritt-für-schritt-nach-der-negativen-kontrolle","Schritt-für-Schritt: Nach der negativen Kontrolle",[34,701,703],{"id":702},"schritt-1-bericht-sorgfältig-lesen","Schritt 1: Bericht sorgfältig lesen",[11,705,706],{},"Gehen Sie jeden Mangel einzeln durch. Notieren Sie sich:",[185,708,709,712,715],{},[137,710,711],{},"Welche Berichtskategorie und welche Legende verwendet der Organismus?",[137,713,714],{},"Wo genau ist das Problem (Raum, Stromkreis)?",[137,716,717],{},"Was genau wird bemängelt?",[34,719,721],{"id":720},"schritt-2-prioritäten-setzen","Schritt 2: Prioritäten setzen",[11,723,724],{},"Beginnen Sie mit allen Feststellungen, die der Bericht als unmittelbare Gefahr, Abschaltgrund oder Hindernis für die Ingebrauchnahme kennzeichnet. Danach planen Sie die übrigen Verstöße nach Abhängigkeit: Erst Ursache und Schutzkonzept, dann Ausführung, Messung und Dokumentation.",[34,726,728],{"id":727},"schritt-3-fachmann-oder-selbst","Schritt 3: Fachmann oder Selbst?",[11,730,731,732,213],{},"Sie können den Bericht ordnen, vorhandene Unterlagen sammeln und Pläne mit der sichtbaren Anlage vergleichen. Ob eine konkrete Korrektur selbst ausgeführt werden darf und sicher ist, hängt von Arbeit, Qualifikation und Zustand der Anlage ab. Arbeiten im Verteiler, an Schutzgeräten, Erdung oder festen Leitungen gehören zu einer ",[14,733,734],{},"Elektrofachkraft",[185,736,737,740,743,746],{},[137,738,739],{},"FI-Schalter nachrüsten oder tauschen",[137,741,742],{},"Erdung verbessern",[137,744,745],{},"Kabel in Schutzrohre verlegen",[137,747,748],{},"Hauptschalter installieren",[34,750,752],{"id":751},"schritt-4-pläne-aktualisieren","Schritt 4: Pläne aktualisieren",[11,754,755,756,759],{},"Eindrahtschema und Situationsplan müssen ",[14,757,758],{},"den aktuellen Zustand"," widerspiegeln. Übernehmen Sie keine vermuteten Leiterquerschnitte oder Schutzwerte. Unbekannte Merkmale werden vor dem Export geklärt oder ausdrücklich als offen behandelt.",[34,761,763],{"id":762},"schritt-5-nachkontrolle-vereinbaren","Schritt 5: Nachkontrolle vereinbaren",[11,765,766],{},"Welcher Organismus zuständig ist, hängt von der Kontrollart ab. Die ergänzende Kontrolle nach einer negativen periodischen Kontrolle erfolgt durch denselben Organismus. Bei der neuen Kontrolle nach einer negativen einschlägigen Verkaufskontrolle kann der Käufer grundsätzlich einen zugelassenen Organismus wählen; die gesamte Installation wird dabei erneut betrachtet. Klären Sie den Umfang anhand des Berichts, bevor Sie buchen.",[22,768,770],{"id":769},"kosten-ohne-scheingenauigkeit-planen","Kosten ohne Scheingenauigkeit planen",[11,772,773],{},"Tarife und Reparaturkosten hängen von Kontrollart, Organismus, Anfahrt, Zahl der Verteiler, Messaufwand und tatsächlichem Mangel ab. Holen Sie den aktuellen Tarif direkt beim Organismus ein. Für Reparaturen sollte ein Angebot die Diagnose, Materialien, Arbeitszeit, Messungen, Plananpassung und neue Kontrolle getrennt ausweisen. Starre Online-Preise können eine verdeckte Leitungsreparatur oder einen Umbau des Verteilers nicht seriös abbilden.",[22,775,777],{"id":776},"belastbare-akte-für-die-neue-kontrolle","Belastbare Akte für die neue Kontrolle",[11,779,780],{},"Führen Sie eine Tabelle mit je einer Zeile pro Feststellung: Berichtstext, betroffener Stromkreis, geplante Maßnahme, verantwortliche Person, Abschlussdatum und Nachweis. Hängen Sie Fotos nur ergänzend an; sie ersetzen keine Messung. Aktualisieren Sie die Pläne erst nach der tatsächlichen Ausführung und prüfen Sie danach noch einmal Beschriftungen und Referenzen.",[11,782,783,784,788,789,793,794,798],{},"Die offizielle ",[264,785,787],{"href":266,"rel":786},[268],"FOD-Seite zu den Arten häuslicher Kontrollen"," erläutert Folgen und Fristen. Für Verkaufssituationen beantwortet die ",[264,790,792],{"href":273,"rel":791},[268],"FAQ für Notare und Immobiliensektor"," unter anderem die 18-Monats-Frist und die Wahl des Organismus. Die ",[264,795,797],{"href":279,"rel":796},[268],"Liste zugelassener Kontrollorganismen"," ist ebenfalls amtlich.",[22,800,802],{"id":801},"feststellung-in-eine-prüfbare-maßnahme-übersetzen","Feststellung in eine prüfbare Maßnahme übersetzen",[11,804,805],{},"Der Bericht beschreibt oft ein Ergebnis, nicht automatisch die technische Ursache. „Isolationswiderstand unzureichend“ kann beispielsweise einen beschädigten Leiter, Feuchtigkeit, ein angeschlossenes Gerät oder eine Kombination betreffen. „Plan stimmt nicht überein“ kann von einer fehlenden Steckdose bis zu einer falschen Schutzgerätefolge reichen. Beauftragen Sie deshalb nicht sofort ein einzelnes Bauteil, sondern lassen Sie Ursache und betroffenen Umfang bestimmen.",[11,807,808],{},"Für jede Feststellung helfen fünf Fragen:",[134,810,811,814,817,820,823],{},[137,812,813],{},"Welcher Anlagenteil wurde tatsächlich kontrolliert?",[137,815,816],{},"Welche Regelstelle oder Schutzfunktion ist betroffen?",[137,818,819],{},"Welche Diagnose oder Messung bestätigt die Ursache?",[137,821,822],{},"Welche Korrektur beseitigt die Ursache, nicht nur das sichtbare Symptom?",[137,824,825],{},"Welcher Nachweis zeigt dem Kontrollorganismus die fertige Korrektur?",[11,827,828],{},"Bei mehreren Verstößen können Abhängigkeiten bestehen. Eine geänderte Verteilung beeinflusst das Eindrahtschema, die Beschriftung, Schutzgeräte und möglicherweise Messwerte. Eine neue Erdungsmaßnahme muss vor der Planfinalisierung und der erneuten Messung abgeschlossen sein. Planen Sie deshalb einen einzigen konsistenten Endstand statt einer Folge widersprüchlicher Zwischenstände.",[22,830,832],{"id":831},"dokumentationsmangel-und-ausführungsmangel-trennen","Dokumentationsmangel und Ausführungsmangel trennen",[11,834,835],{},"Ein fehlender Plan wird nicht dadurch behoben, dass ein nicht verifizierter Plan gezeichnet wird. Erfassen Sie zuerst die Anlage. Öffnen und messen darf nur, wer dies sicher und fachgerecht ausführen kann. Ordnen Sie anschließend jedem Symbol den tatsächlichen Stromkreis zu und prüfen Sie, ob Verteilerbeschriftung, Eindrahtschema und Situationsplan dieselbe Referenz verwenden.",[11,837,838],{},"Ein Ausführungsmangel wird umgekehrt nicht durch eine schönere Zeichnung behoben. Ist ein Schutzgerät ungeeignet, die Erdung unzureichend oder eine Leitung mechanisch gefährdet, muss die physische Anlage korrigiert und gegebenenfalls erneut gemessen werden. Der Plan wird danach auf den ausgeführten Zustand gebracht. Diese Reihenfolge verhindert, dass die neue Kontrolle zwar aktuelle Unterlagen, aber eine unveränderte Gefahr vorfindet.",[22,840,842],{"id":841},"sonderfall-verkauf","Sonderfall Verkauf",[11,844,845],{},"Bei einer negativen Verkaufskontrolle sollte der Käufer Bericht, authentische Urkunde und Installationsdossier gemeinsam aufbewahren. Die 18 Monate beginnen am Tag der authentischen Urkunde. Der Käufer teilt dem ursprünglichen Organismus Identität und Datum mit. Wird ein anderer zugelassener Organismus für die neue Kontrolle gewählt, informiert dieser den ersten Organismus nach der offiziellen Beschreibung.",[11,847,848],{},"Die Frist ist kein Aufschub für erkennbare Gefahren. Unsichere Anlagenteile sollten sofort von einer Fachkraft bewertet und gegebenenfalls außer Betrieb genommen werden. Wenn innerhalb der Verkaufsfrist weiterverkauft, vollständig renoviert oder abgerissen werden soll, gelten besondere Abläufe; klären Sie diese anhand der FOD-FAQ und der notariellen Situation, statt eine allgemeine Internetantwort zu übernehmen.",[22,850,852],{"id":851},"änderungen-bis-zur-nachkontrolle-beherrschen","Änderungen bis zur Nachkontrolle beherrschen",[11,854,855],{},"Fixieren Sie nach der Mängelbeseitigung einen dokumentierten Stand: datierte Pläne, Verteilerbeschriftung, Messunterlagen und Fotos der nicht mehr sichtbaren Arbeiten. Jede weitere Änderung vor dem Kontrolltermin wird gegen diesen Stand geprüft und gegebenenfalls nachgeführt. Sonst kann eine kleine zusätzliche Leitung genau die Übereinstimmung zerstören, die Elektriker und Planer zuvor hergestellt haben. Weisen Sie alle Nutzer darauf hin, provisorische Anschlüsse und eigenständige Umbauten bis zur Kontrolle zu vermeiden. Muss doch etwas geändert werden, erhält die verantwortliche Fachkraft Bericht, aktuelle Pläne und eine eindeutige Beschreibung der Änderung. So bleibt der Nachweis geschlossen und der Kontrolleur beurteilt nicht versehentlich eine andere Anlage als die vorbereitete.",[22,857,859],{"id":858},"letzter-check-vor-dem-neuen-termin","Letzter Check vor dem neuen Termin",[185,861,862,865,868,871,874,877,880],{},[137,863,864],{},"Alle Feststellungen sind einer abgeschlossenen Maßnahme zugeordnet.",[137,866,867],{},"Messpflichtige Korrekturen wurden fachgerecht gemessen und dokumentiert.",[137,869,870],{},"Stromkreiskennzeichen stimmen in Verteiler und beiden Plänen überein.",[137,872,873],{},"Neue oder entfernte Geräte sind im Situationsplan nachgeführt.",[137,875,876],{},"Nennwerte und Leitungsangaben im Eindrahtschema entsprechen der Ausführung.",[137,878,879],{},"Der richtige Organismus und der richtige Kontrolltyp sind bestätigt.",[137,881,882],{},"Bericht, Pläne, EAN-Nummer und relevante Herstellerunterlagen liegen bereit.",[11,884,885],{},"Damit versprechen Sie keinen positiven Bericht. Sie vermeiden aber, dass eine erledigte Reparatur wegen widersprüchlicher Unterlagen oder fehlender Nachweise nicht nachvollziehbar ist.",[11,887,888],{},"Planen Sie außerdem Zeit für Rückfragen und gegebenenfalls eine zweite Diagnose ein. Erst wenn Ursache, Ausführung und Nachweis zusammenpassen, ist die Feststellung wirklich bearbeitet; ein bloßer Haken in einer Aufgabenliste genügt nicht.",[22,890,892],{"id":891},"wie-planelec-hilft","Wie PlanElec hilft",[11,894,895,896,899],{},"PlanElec kann einige unterstützte, aus den erfassten Daten ableitbare Planungsprobleme ",[14,897,898],{},"vor der Kontrolle"," anzeigen:",[185,901,902,908,914,920],{},[137,903,904,907],{},[14,905,906],{},"Validierung"," weist auf unterstützte Angaben zu FI-Schutz und Absicherung hin",[137,909,910,913],{},[14,911,912],{},"Eindrahtschema"," bildet die eingegebene Topologie strukturiert ab",[137,915,916,919],{},[14,917,918],{},"Situationsplan"," verwendet die unterstützte belgische Symbolbibliothek",[137,921,922,925],{},[14,923,924],{},"Beschriftung"," aller Stromkreise wird automatisch im Schema dokumentiert",[11,927,928],{},"Der Selbstcheck ist keine Konformitätsbescheinigung, führt keine Messungen aus und garantiert kein positives Ergebnis. Er unterstützt eine konsistente Akte für die fachliche Prüfung.",[410,930],{},[11,932,933],{},[14,934,935],{},"Verwandte Artikel:",[185,937,938,944,950],{},[137,939,940],{},[264,941,943],{"href":942},"\u002Fde\u002Fblog\u002F10-haeufigste-arei-verstoesse","Die 10 häufigsten AREI-Verstöße",[137,945,946],{},[264,947,949],{"href":948},"\u002Fde\u002Fblog\u002F30ma-fi-schutzschalter","30 mA FI-Schutzschalter: Wann ist er Pflicht?",[137,951,952],{},[264,953,955],{"href":954},"\u002Fde\u002Fblog\u002Fkabelquerschnitt-sicherung","Kabelquerschnitt und Sicherung: Die richtige Kombination",[11,957,958,442,961],{},[14,959,960],{},"Bereiten Sie Ihre Unterlagen strukturiert vor und lassen Sie Ausführung und offene Fachfragen vor der offiziellen Kontrolle prüfen.",[264,962,964],{"href":445,"rel":963},[268],"Jetzt starten →",{"title":449,"searchDepth":450,"depth":450,"links":966},[967,970,975,976,983,984,985,986,987,988,989,990],{"id":516,"depth":450,"text":517,"children":968},[969],{"id":527,"depth":455,"text":528},{"id":534,"depth":450,"text":535,"children":971},[972,973,974],{"id":538,"depth":455,"text":539},{"id":549,"depth":455,"text":550},{"id":556,"depth":455,"text":557},{"id":567,"depth":450,"text":568},{"id":698,"depth":450,"text":699,"children":977},[978,979,980,981,982],{"id":702,"depth":455,"text":703},{"id":720,"depth":455,"text":721},{"id":727,"depth":455,"text":728},{"id":751,"depth":455,"text":752},{"id":762,"depth":455,"text":763},{"id":769,"depth":450,"text":770},{"id":776,"depth":450,"text":777},{"id":801,"depth":450,"text":802},{"id":831,"depth":450,"text":832},{"id":841,"depth":450,"text":842},{"id":851,"depth":450,"text":852},{"id":858,"depth":450,"text":859},{"id":891,"depth":450,"text":892},"Ihre Elektrokontrolle ist negativ? So lesen Sie den Bericht, bestimmen die geltende Frist, planen sichere Korrekturen und bereiten die neue Kontrolle vor.","de",{},"\u002Fblog\u002Finspection-failed-what-now.de",{"title":502,"description":991},"stromabnahme-durchgefallen","blog\u002Finspection-failed-what-now.de",[999,1000,1001,1002,1003,496,1004],"keuring","elektrokontrolle","durchgefallen","mängel","nachkontrolle","belgien","2VJ6MzoTpg_PnFHfFgfWR6dbGYclS73I4JMCZJelc7Q",{"id":4,"title":5,"articleId":6,"body":1007,"category":477,"date":478,"description":479,"extension":480,"lastUpdated":481,"locale":482,"meta":1307,"navigation":484,"path":485,"publishDate":478,"readTime":486,"refreshInterval":487,"seo":1308,"slug":6,"stem":489,"tags":1309,"__hash__":498},{"type":8,"value":1008,"toc":1281},[1009,1013,1015,1017,1021,1023,1059,1061,1063,1065,1069,1071,1073,1075,1079,1081,1083,1105,1107,1109,1111,1113,1115,1123,1125,1127,1129,1133,1143,1145,1149,1151,1153,1155,1157,1159,1161,1172,1174,1176,1178,1190,1192,1194,1196,1198,1200,1202,1204,1206,1208,1210,1226,1228,1230,1234,1252,1254,1256,1260,1274],[11,1010,1011,17],{},[14,1012,16],{},[11,1014,20],{},[22,1016,25],{"id":24},[11,1018,28,1019,32],{},[14,1020,31],{},[34,1022,37],{"id":36},[39,1024,1025,1033],{},[42,1026,1027],{},[45,1028,1029,1031],{},[48,1030,50],{},[48,1032,53],{},[55,1034,1035,1041,1047,1053],{},[45,1036,1037,1039],{},[60,1038,62],{},[60,1040,65],{},[45,1042,1043,1045],{},[60,1044,70],{},[60,1046,73],{},[45,1048,1049,1051],{},[60,1050,78],{},[60,1052,81],{},[45,1054,1055,1057],{},[60,1056,86],{},[60,1058,89],{},[11,1060,92],{},[22,1062,96],{"id":95},[34,1064,100],{"id":99},[11,1066,103,1067,107],{},[14,1068,106],{},[34,1070,111],{"id":110},[11,1072,114],{},[34,1074,118],{"id":117},[11,1076,121,1077,125],{},[14,1078,124],{},[22,1080,129],{"id":128},[11,1082,132],{},[134,1084,1085,1087,1089,1091,1093,1095,1097,1099,1101,1103],{},[137,1086,139],{},[137,1088,142],{},[137,1090,145],{},[137,1092,148],{},[137,1094,151],{},[137,1096,154],{},[137,1098,157],{},[137,1100,160],{},[137,1102,163],{},[137,1104,166],{},[11,1106,169],{},[11,1108,172],{},[22,1110,176],{"id":175},[34,1112,180],{"id":179},[11,1114,183],{},[185,1116,1117,1119,1121],{},[137,1118,189],{},[137,1120,192],{},[137,1122,195],{},[34,1124,199],{"id":198},[11,1126,202],{},[34,1128,206],{"id":205},[11,1130,209,1131,213],{},[14,1132,212],{},[185,1134,1135,1137,1139,1141],{},[137,1136,218],{},[137,1138,221],{},[137,1140,224],{},[137,1142,227],{},[34,1144,231],{"id":230},[11,1146,234,1147,238],{},[14,1148,237],{},[34,1150,242],{"id":241},[11,1152,245],{},[22,1154,249],{"id":248},[11,1156,252],{},[22,1158,256],{"id":255},[11,1160,259],{},[11,1162,262,1163,270,1166,276,1169,282],{},[264,1164,269],{"href":266,"rel":1165},[268],[264,1167,275],{"href":273,"rel":1168},[268],[264,1170,281],{"href":279,"rel":1171},[268],[22,1173,286],{"id":285},[11,1175,289],{},[11,1177,292],{},[134,1179,1180,1182,1184,1186,1188],{},[137,1181,297],{},[137,1183,300],{},[137,1185,303],{},[137,1187,306],{},[137,1189,309],{},[11,1191,312],{},[22,1193,316],{"id":315},[11,1195,319],{},[11,1197,322],{},[22,1199,326],{"id":325},[11,1201,329],{},[11,1203,332],{},[22,1205,336],{"id":335},[11,1207,339],{},[22,1209,343],{"id":342},[185,1211,1212,1214,1216,1218,1220,1222,1224],{},[137,1213,348],{},[137,1215,351],{},[137,1217,354],{},[137,1219,357],{},[137,1221,360],{},[137,1223,363],{},[137,1225,366],{},[11,1227,369],{},[22,1229,373],{"id":372},[11,1231,376,1232,213],{},[14,1233,379],{},[185,1235,1236,1240,1244,1248],{},[137,1237,1238,387],{},[14,1239,386],{},[137,1241,1242,393],{},[14,1243,392],{},[137,1245,1246,399],{},[14,1247,398],{},[137,1249,1250,405],{},[14,1251,404],{},[11,1253,408],{},[410,1255],{},[11,1257,1258],{},[14,1259,416],{},[185,1261,1262,1266,1270],{},[137,1263,1264],{},[264,1265,424],{"href":423},[137,1267,1268],{},[264,1269,430],{"href":429},[137,1271,1272],{},[264,1273,436],{"href":435},[11,1275,1276,442,1278],{},[14,1277,441],{},[264,1279,447],{"href":445,"rel":1280},[268],{"title":449,"searchDepth":450,"depth":450,"links":1282},[1283,1286,1291,1292,1299,1300,1301,1302,1303,1304,1305,1306],{"id":24,"depth":450,"text":25,"children":1284},[1285],{"id":36,"depth":455,"text":37},{"id":95,"depth":450,"text":96,"children":1287},[1288,1289,1290],{"id":99,"depth":455,"text":100},{"id":110,"depth":455,"text":111},{"id":117,"depth":455,"text":118},{"id":128,"depth":450,"text":129},{"id":175,"depth":450,"text":176,"children":1293},[1294,1295,1296,1297,1298],{"id":179,"depth":455,"text":180},{"id":198,"depth":455,"text":199},{"id":205,"depth":455,"text":206},{"id":230,"depth":455,"text":231},{"id":241,"depth":455,"text":242},{"id":248,"depth":450,"text":249},{"id":255,"depth":450,"text":256},{"id":285,"depth":450,"text":286},{"id":315,"depth":450,"text":316},{"id":325,"depth":450,"text":326},{"id":335,"depth":450,"text":336},{"id":342,"depth":450,"text":343},{"id":372,"depth":450,"text":373},{},{"title":5,"description":479},[491,492,493,494,495,496,497],{"id":1311,"title":1312,"articleId":6,"body":1313,"category":477,"date":478,"description":1755,"extension":480,"lastUpdated":481,"locale":1756,"meta":1757,"navigation":484,"path":1758,"publishDate":478,"readTime":486,"refreshInterval":487,"seo":1759,"slug":1760,"stem":1761,"tags":1762,"__hash__":1770},"blog\u002Fblog\u002Finspection-failed-what-now.fr.md","Contrôle électrique refusé — que faire ? Guide étape par étape après un contrôle négatif",{"type":8,"value":1314,"toc":1729},[1315,1321,1324,1328,1335,1339,1385,1388,1392,1396,1403,1407,1410,1414,1421,1425,1428,1460,1463,1467,1471,1474,1485,1489,1492,1496,1503,1517,1521,1528,1532,1535,1539,1542,1546,1549,1567,1571,1574,1577,1594,1597,1601,1604,1607,1611,1614,1617,1621,1624,1628,1651,1654,1658,1664,1690,1693,1695,1700,1720],[11,1316,1317,1320],{},[14,1318,1319],{},"Procédez avec méthode."," Les sources officielles utilisées ici ne publient pas de pourcentage national fiable de contrôles négatifs. Un rapport négatif ne permet pas non plus de conclure, en général, qu'il s'agit uniquement de documents ou d'un danger immédiat. Chaque constat du rapport fait foi.",[11,1322,1323],{},"Dans ce guide, vous découvrirez ce qu'il faut faire après un contrôle négatif, quels sont les codes d'infraction et comment vous préparer au recontrôle.",[22,1325,1327],{"id":1326},"que-se-passe-t-il-après-un-contrôle-négatif","Que se passe-t-il après un contrôle négatif ?",[11,1329,1330,1331,1334],{},"Après le contrôle, vous recevez un ",[14,1332,1333],{},"rapport détaillé"," de l'organisme agréé. Il indique les infractions, les parties concernées et la conclusion.",[34,1336,1338],{"id":1337},"lire-les-codes-avec-la-légende-du-rapport","Lire les codes avec la légende du rapport",[39,1340,1341,1351],{},[42,1342,1343],{},[45,1344,1345,1348],{},[48,1346,1347],{},"Champ du rapport",[48,1349,1350],{},"Ce qu'il permet de déterminer",[55,1352,1353,1361,1369,1377],{},[45,1354,1355,1358],{},[60,1356,1357],{},"Code ou catégorie",[60,1359,1360],{},"Sens donné uniquement par la légende de ce rapport",[45,1362,1363,1366],{},[60,1364,1365],{},"Référence",[60,1367,1368],{},"Prescription et fonction de protection contestées",[45,1370,1371,1374],{},[60,1372,1373],{},"Lieu ou circuit",[60,1375,1376],{},"Partie de l'installation concernée sans ambiguïté",[45,1378,1379,1382],{},[60,1380,1381],{},"Conclusion et délai",[60,1383,1384],{},"Conséquence du type de contrôle réel, pas d'un code générique",[11,1386,1387],{},"Les codes et classes de priorité peuvent varier selon l'organisme et son modèle. Ne déduisez pas un délai belge universel de « C1 », « C2 » ou « C3 ». Utilisez la légende du rapport et demandez au rédacteur de préciser la référence, le circuit et la preuve attendue. Tout danger immédiat signalé est prioritaire, quel que soit le code abrégé.",[22,1389,1391],{"id":1390},"délais-selon-la-situation","Délais selon la situation",[34,1393,1395],{"id":1394},"lors-dune-vente-immobilière","Lors d'une vente immobilière",[11,1397,1398,1399,1402],{},"Pour le contrôle « vente » concerné d'une ancienne habitation, l'acheteur dispose en principe de ",[14,1400,1401],{},"18 mois à compter de l'acte authentique",", et non d'une simple offre privée, pour remettre en ordre et organiser une nouvelle visite.",[34,1404,1406],{"id":1405},"pour-une-nouvelle-installation","Pour une nouvelle installation",[11,1408,1409],{},"Pour une installation neuve ou une modification importante, la partie en infraction ne peut pas être mise en usage. Il faut d'abord corriger puis faire réaliser un nouveau contrôle de conformité. Toute procédure de raccordement se vérifie séparément auprès du gestionnaire concerné.",[34,1411,1413],{"id":1412},"lors-du-contrôle-périodique","Lors du contrôle périodique",[11,1415,1416,1417,1420],{},"Après un contrôle périodique négatif, l'information fédérale prévoit une visite complémentaire par ",[14,1418,1419],{},"le même organisme dans les douze mois",". Vérifiez toujours le type de contrôle et les instructions du rapport.",[22,1422,1424],{"id":1423},"dix-domaines-à-vérifier-sans-classement-statistique","Dix domaines à vérifier, sans classement statistique",[11,1426,1427],{},"Utilisez ces domaines comme aide de lecture, sans prétendre à une fréquence nationale ni à un verdict automatique :",[134,1429,1430,1433,1436,1439,1442,1445,1448,1451,1454,1457],{},[137,1431,1432],{},"protection différentielle adaptée à chaque circuit et récepteur ;",[137,1434,1435],{},"cohérence du schéma unifilaire, du plan de situation et des étiquettes ;",[137,1437,1438],{},"terre, liaisons équipotentielles et coupure automatique étayées par des mesures ;",[137,1440,1441],{},"identification claire des circuits et protections ;",[137,1443,1444],{},"choix et protection mécanique des canalisations selon leur mode de pose ;",[137,1446,1447],{},"règles des emplacements spéciaux, dont la géométrie réelle de la salle de bains ;",[137,1449,1450],{},"commande et sectionnement principaux adaptés à l'installation ;",[137,1452,1453],{},"coordination des conducteurs, conditions de pose et protections contre les surintensités ;",[137,1455,1456],{},"évaluation explicite de la protection contre les surtensions ;",[137,1458,1459],{},"séparation entre constats RGIE et obligations régionales de logement, comme les détecteurs de fumée.",[11,1461,1462],{},"Le constat exact du contrôleur et le Livre 1 en vigueur déterminent la correction. Une liste ne remplace ni diagnostic, ni mesure, ni rapport.",[22,1464,1466],{"id":1465},"étape-par-étape-après-le-contrôle-négatif","Étape par étape : après le contrôle négatif",[34,1468,1470],{"id":1469},"étape-1-lire-attentivement-le-rapport","Étape 1 : Lire attentivement le rapport",[11,1472,1473],{},"Examinez chaque infraction individuellement. Notez :",[185,1475,1476,1479,1482],{},[137,1477,1478],{},"Quelle catégorie et quelle légende le rapport emploie-t-il ?",[137,1480,1481],{},"Où se situe exactement le problème (pièce, circuit) ?",[137,1483,1484],{},"Que reproche-t-on exactement ?",[34,1486,1488],{"id":1487},"étape-2-établir-les-priorités","Étape 2 : Établir les priorités",[11,1490,1491],{},"Commencez par tout constat qualifié de danger immédiat, de motif de coupure ou d'obstacle à la mise en usage. Ordonnez ensuite les autres travaux par dépendance : cause et concept de protection, réalisation, mesure puis documentation.",[34,1493,1495],{"id":1494},"étape-3-professionnel-ou-soi-même","Étape 3 : Professionnel ou soi-même ?",[11,1497,1498,1499,1502],{},"Vous pouvez classer le rapport, rassembler les documents et comparer les plans au matériel visible. La possibilité de corriger soi-même dépend du travail et des compétences. Les interventions dans le tableau, sur les protections, la terre ou les canalisations fixes relèvent d'un ",[14,1500,1501],{},"professionnel"," :",[185,1504,1505,1508,1511,1514],{},[137,1506,1507],{},"Ajouter ou remplacer le différentiel",[137,1509,1510],{},"Améliorer la mise à la terre",[137,1512,1513],{},"Placer les câbles dans des tubes de protection",[137,1515,1516],{},"Installer l'interrupteur principal",[34,1518,1520],{"id":1519},"étape-4-mettre-à-jour-les-plans","Étape 4 : Mettre à jour les plans",[11,1522,1523,1524,1527],{},"Le schéma unifilaire et le plan de situation doivent refléter ",[14,1525,1526],{},"l'état actuel",". N'inventez ni section de conducteur ni calibre. Faites déterminer les caractéristiques inconnues avant l'export ou marquez-les comme ouvertes.",[34,1529,1531],{"id":1530},"étape-5-planifier-le-recontrôle","Étape 5 : Planifier le recontrôle",[11,1533,1534],{},"L'organisme compétent dépend de la procédure. La visite complémentaire après contrôle périodique négatif revient au même organisme. Après le contrôle « vente » négatif concerné, l'acheteur peut en principe choisir un organisme agréé et la nouvelle visite porte sur l'ensemble de l'installation. Confirmez la portée avant de réserver.",[22,1536,1538],{"id":1537},"budgéter-sans-fausse-précision","Budgéter sans fausse précision",[11,1540,1541],{},"Tarifs et réparations dépendent de la procédure, de l'organisme, du déplacement, des tableaux, des mesures et du défaut réel. Demandez le tarif actuel directement. Un devis de correction devrait séparer diagnostic, matériel, travail, mesures, mise à jour des plans et nouvelle visite. Une fourchette en ligne ne représente pas une canalisation cachée ou une reconstruction de tableau.",[22,1543,1545],{"id":1544},"constituer-la-preuve-pour-la-nouvelle-visite","Constituer la preuve pour la nouvelle visite",[11,1547,1548],{},"Tenez une ligne par constat : texte du rapport, circuit, action, responsable, date d'achèvement et preuve. Les photos complètent le dossier sans remplacer les mesures. Actualisez les plans après la réalisation, puis rapprochez encore repères et étiquettes.",[11,1550,1551,1552,1556,1557,1561,1562,1566],{},"La ",[264,1553,1555],{"href":266,"rel":1554},[268],"page officielle des types de contrôles domestiques"," explique conséquences et délais. La ",[264,1558,1560],{"href":273,"rel":1559},[268],"FAQ fédérale sur la vente"," détaille les dix-huit mois et le choix de l'organisme. Consultez aussi la ",[264,1563,1565],{"href":279,"rel":1564},[268],"liste officielle des organismes agréés",".",[22,1568,1570],{"id":1569},"transformer-chaque-constat-en-action-vérifiable","Transformer chaque constat en action vérifiable",[11,1572,1573],{},"Le rapport décrit souvent un résultat et non sa cause technique. Un isolement insuffisant peut venir d'un conducteur endommagé, d'humidité, d'un appareil raccordé ou de plusieurs causes. « Plan non conforme à l'installation » peut désigner une prise absente du dessin comme un mauvais ordre de protections. Ne commandez donc pas immédiatement une pièce : déterminez la cause et la portée.",[11,1575,1576],{},"Pour chaque constat, posez cinq questions :",[134,1578,1579,1582,1585,1588,1591],{},[137,1580,1581],{},"quelle partie a effectivement été contrôlée ?",[137,1583,1584],{},"quelle règle ou fonction de protection est concernée ?",[137,1586,1587],{},"quel diagnostic ou quelle mesure confirme la cause ?",[137,1589,1590],{},"quelle correction élimine la cause plutôt que son apparence ?",[137,1592,1593],{},"quelle preuve permettra à l'organisme de vérifier la correction terminée ?",[11,1595,1596],{},"Des constats peuvent dépendre les uns des autres. Une modification de tableau change schéma unifilaire, étiquettes, protections et parfois mesures. Une intervention sur la terre doit précéder les plans finaux et nouvelles mesures. Visez un état final cohérent plutôt qu'une série d'états intermédiaires contradictoires.",[22,1598,1600],{"id":1599},"séparer-défaut-documentaire-et-défaut-physique","Séparer défaut documentaire et défaut physique",[11,1602,1603],{},"Un plan manquant ne se corrige pas en dessinant des hypothèses. Relevez d'abord l'installation ; l'ouverture et la mesure sont réservées à une personne compétente et équipée. Reliez ensuite chaque symbole au circuit réel et vérifiez que tableau, schéma unifilaire et plan de situation utilisent le même repère.",[11,1605,1606],{},"Un défaut physique ne disparaît pas avec un meilleur dessin. Si une protection est inadéquate, la terre insuffisante ou un câble exposé, l'installation doit être corrigée puis, si nécessaire, mesurée. Le plan est mis à jour après la réalisation. Cette séquence évite de présenter des documents neufs devant un danger inchangé.",[22,1608,1610],{"id":1609},"cas-particulier-de-la-vente","Cas particulier de la vente",[11,1612,1613],{},"Après un contrôle « vente » négatif, conservez ensemble rapport, acte authentique et dossier. Les dix-huit mois partent de l'acte authentique. L'acheteur communique son identité et la date à l'organisme initial. Si un autre organisme agréé est choisi pour la nouvelle visite, l'explication fédérale prévoit que celui-ci informe le premier.",[11,1615,1616],{},"Le délai n'autorise pas à ignorer un danger manifeste. Faites évaluer rapidement les parties incertaines et mettez-les hors service si nécessaire. Une revente, une rénovation totale ou une démolition pendant ce délai peut modifier la procédure : consultez la FAQ fédérale et le contexte notarial concret.",[22,1618,1620],{"id":1619},"maîtriser-les-changements-avant-la-nouvelle-visite","Maîtriser les changements avant la nouvelle visite",[11,1622,1623],{},"Après correction, figez un état documenté : plans datés, repérage du tableau, mesures et photos des travaux qui seront ensuite cachés. Comparez toute modification ultérieure à cet état et actualisez le dossier si nécessaire. Un câble ajouté en apparence anodin peut sinon rompre la cohérence établie par l'électricien et le dessinateur. Demandez aux utilisateurs d'éviter raccordements provisoires et transformations autonomes avant le rendez-vous. Si un changement est indispensable, transmettez au professionnel responsable le rapport, les plans actuels et une description précise des nouveaux travaux. La chaîne de preuve reste ainsi continue et le contrôleur n'examine pas, sans le savoir, une installation différente de celle préparée.",[22,1625,1627],{"id":1626},"dernière-vérification-avant-le-rendez-vous","Dernière vérification avant le rendez-vous",[185,1629,1630,1633,1636,1639,1642,1645,1648],{},[137,1631,1632],{},"Chaque constat correspond à une action terminée.",[137,1634,1635],{},"Les corrections nécessitant des mesures disposent de résultats.",[137,1637,1638],{},"Les repères concordent entre tableau et deux plans.",[137,1640,1641],{},"Le matériel ajouté ou retiré figure au plan de situation.",[137,1643,1644],{},"Calibres et câbles correspondent au schéma réalisé.",[137,1646,1647],{},"L'organisme et le type de contrôle sont confirmés.",[137,1649,1650],{},"Rapport, plans, code EAN et notices utiles sont prêts.",[11,1652,1653],{},"Cette préparation ne promet pas un rapport positif. Elle évite qu'une réparation terminée soit impossible à vérifier à cause de documents contradictoires.",[22,1655,1657],{"id":1656},"comment-planelec-vous-aide","Comment PlanElec vous aide",[11,1659,1660,1661,1502],{},"PlanElec peut détecter bon nombre des causes de refus les plus fréquentes ",[14,1662,1663],{},"AVANT le contrôle",[185,1665,1666,1672,1678,1684],{},[137,1667,1668,1671],{},[14,1669,1670],{},"La validation"," signale des données prises en charge sur les différentiels et protections",[137,1673,1674,1677],{},[14,1675,1676],{},"Le schéma unifilaire"," représente de façon cohérente la topologie saisie",[137,1679,1680,1683],{},[14,1681,1682],{},"Le plan de situation"," utilise la bibliothèque belge prise en charge",[137,1685,1686,1689],{},[14,1687,1688],{},"L'étiquetage"," de tous les circuits est automatiquement documenté dans le schéma",[11,1691,1692],{},"L'autocontrôle n'est pas une attestation, n'effectue aucune mesure et ne garantit pas un résultat positif. Il aide à produire un dossier cohérent pour l'examen professionnel.",[410,1694],{},[11,1696,1697],{},[14,1698,1699],{},"Articles connexes :",[185,1701,1702,1708,1714],{},[137,1703,1704],{},[264,1705,1707],{"href":1706},"\u002Ffr\u002Fblog\u002F10-infractions-rgie-frequentes","Les 10 infractions RGIE les plus fréquentes",[137,1709,1710],{},[264,1711,1713],{"href":1712},"\u002Ffr\u002Fblog\u002Fdifferentiel-30ma","Différentiel 30 mA : quand est-il obligatoire ?",[137,1715,1716],{},[264,1717,1719],{"href":1718},"\u002Ffr\u002Fblog\u002Fsection-cable-disjoncteur","Section de câble et disjoncteur : la bonne combinaison",[11,1721,1722,442,1725],{},[14,1723,1724],{},"Préparez vos plans électriques avec PlanElec et utilisez l'auto-contrôle comme aide avant la vérification professionnelle et le contrôle officiel.",[264,1726,1728],{"href":445,"rel":1727},[268],"Commencer maintenant →",{"title":449,"searchDepth":450,"depth":450,"links":1730},[1731,1734,1739,1740,1747,1748,1749,1750,1751,1752,1753,1754],{"id":1326,"depth":450,"text":1327,"children":1732},[1733],{"id":1337,"depth":455,"text":1338},{"id":1390,"depth":450,"text":1391,"children":1735},[1736,1737,1738],{"id":1394,"depth":455,"text":1395},{"id":1405,"depth":455,"text":1406},{"id":1412,"depth":455,"text":1413},{"id":1423,"depth":450,"text":1424},{"id":1465,"depth":450,"text":1466,"children":1741},[1742,1743,1744,1745,1746],{"id":1469,"depth":455,"text":1470},{"id":1487,"depth":455,"text":1488},{"id":1494,"depth":455,"text":1495},{"id":1519,"depth":455,"text":1520},{"id":1530,"depth":455,"text":1531},{"id":1537,"depth":450,"text":1538},{"id":1544,"depth":450,"text":1545},{"id":1569,"depth":450,"text":1570},{"id":1599,"depth":450,"text":1600},{"id":1609,"depth":450,"text":1610},{"id":1619,"depth":450,"text":1620},{"id":1626,"depth":450,"text":1627},{"id":1656,"depth":450,"text":1657},"Votre contrôle est négatif ? Apprenez à lire le rapport, déterminer le délai applicable, planifier des corrections sûres et préparer la nouvelle visite.","fr",{},"\u002Fblog\u002Finspection-failed-what-now.fr",{"title":1312,"description":1755},"controle-electrique-refuse","blog\u002Finspection-failed-what-now.fr",[1763,1764,1765,1766,1767,1768,1769],"controle","controle-electrique","refuse","infractions","recontrole","rgie","belgique","LiLl3zQch0mbSuxpoAr0wXlFDlKXeVajF73_5Z0KsjM",{"id":1772,"title":1773,"articleId":6,"body":1774,"category":477,"date":478,"description":2230,"extension":480,"lastUpdated":481,"locale":2231,"meta":2232,"navigation":484,"path":2233,"publishDate":478,"readTime":486,"refreshInterval":487,"seo":2234,"slug":2235,"stem":2236,"tags":2237,"__hash__":2243},"blog\u002Fblog\u002Finspection-failed-what-now.nl.md","Elektrokeuring afgekeurd — wat nu? Stap-voor-stap gids na een negatieve keuring",{"type":8,"value":1775,"toc":2204},[1776,1782,1785,1789,1796,1800,1846,1849,1853,1857,1864,1868,1871,1875,1882,1886,1889,1921,1924,1928,1931,1934,1937,1940,1944,1948,1951,1962,1966,1969,1973,1979,1993,1997,2004,2008,2011,2015,2018,2022,2025,2042,2046,2049,2052,2069,2072,2076,2079,2082,2086,2089,2092,2096,2119,2122,2125,2128,2132,2139,2165,2168,2170,2175,2195],[11,1777,1778,1781],{},[14,1779,1780],{},"Werk methodisch."," De gebruikte officiële bronnen publiceren geen betrouwbaar nationaal percentage negatieve keuringen. Uit een negatief verslag volgt evenmin algemeen of het alleen om documenten of om onmiddellijk gevaar gaat. De afzonderlijke vaststellingen in het verslag zijn bepalend.",[11,1783,1784],{},"In deze gids leest u wat er na een negatieve keuring moet gebeuren, welke inbreukcodes er bestaan en hoe u zich voorbereidt op de herkeuring.",[22,1786,1788],{"id":1787},"wat-gebeurt-er-na-een-negatieve-keuring","Wat gebeurt er na een negatieve keuring?",[11,1790,1791,1792,1795],{},"Na de keuring ontvangt u een ",[14,1793,1794],{},"uitgebreid verslag"," van het erkende organisme. Het vermeldt inbreuken, betrokken installatiedelen en conclusie.",[34,1797,1799],{"id":1798},"lees-codes-met-de-legende-van-het-verslag","Lees codes met de legende van het verslag",[39,1801,1802,1812],{},[42,1803,1804],{},[45,1805,1806,1809],{},[48,1807,1808],{},"Veld in het verslag",[48,1810,1811],{},"Wat u eruit afleidt",[55,1813,1814,1822,1830,1838],{},[45,1815,1816,1819],{},[60,1817,1818],{},"Code of categorie",[60,1820,1821],{},"Betekenis uitsluitend volgens de legende van dit verslag",[45,1823,1824,1827],{},[60,1825,1826],{},"Regelverwijzing",[60,1828,1829],{},"Voorschrift en beveiligingsfunctie die worden betwist",[45,1831,1832,1835],{},[60,1833,1834],{},"Plaats of kring",[60,1836,1837],{},"Eenduidig betrokken installatiedeel",[45,1839,1840,1843],{},[60,1841,1842],{},"Conclusie en termijn",[60,1844,1845],{},"Gevolg van het werkelijke controletype, niet van een algemene korte code",[11,1847,1848],{},"Codes en prioriteitsklassen kunnen per organisme en verslagmodel verschillen. Leid uit “C1”, “C2” of “C3” geen universele Belgische termijn af. Gebruik de legende in het concrete verslag en vraag de opsteller om regelreferentie, kring en verwacht bewijs te verduidelijken. Een vermelding van onmiddellijk gevaar krijgt voorrang, ongeacht de korte code.",[22,1850,1852],{"id":1851},"termijnen-per-situatie","Termijnen per situatie",[34,1854,1856],{"id":1855},"bij-verkoop-van-vastgoed","Bij verkoop van vastgoed",[11,1858,1859,1860,1863],{},"Bij de relevante verkoopkeuring van een oude woning heeft de koper in beginsel ",[14,1861,1862],{},"18 maanden vanaf de authentieke akte",", niet gewoon vanaf een onderhandse overeenkomst, om de installatie in orde te brengen en een nieuwe controle te organiseren.",[34,1865,1867],{"id":1866},"bij-nieuwe-installatie","Bij nieuwe installatie",[11,1869,1870],{},"Bij een nieuwe installatie of belangrijke wijziging mag het deel met inbreuken niet in gebruik worden genomen. Eerst volgt herstel en daarna een nieuwe gelijkvormigheidscontrole. Een netaansluitingsproces wordt daarnaast apart met de bevoegde netbeheerder afgestemd.",[34,1872,1874],{"id":1873},"bij-periodieke-keuring","Bij periodieke keuring",[11,1876,1877,1878,1881],{},"Na een negatieve periodieke keuring beschrijft de federale informatie een aanvullende controle door ",[14,1879,1880],{},"hetzelfde organisme binnen twaalf maanden",". Controleer toch altijd controletype en bijzondere instructies in het verslag.",[22,1883,1885],{"id":1884},"tien-controlegebieden-geen-statistische-rangschikking","Tien controlegebieden, geen statistische rangschikking",[11,1887,1888],{},"Gebruik deze domeinen als leeshulp, niet als nationale frequentierangschikking of automatisch oordeel:",[134,1890,1891,1894,1897,1900,1903,1906,1909,1912,1915,1918],{},[137,1892,1893],{},"differentieelbescherming afgestemd op elke kring en belasting;",[137,1895,1896],{},"eendraadschema, situatieplan en bordlabels die dezelfde installatie beschrijven;",[137,1898,1899],{},"aarding, equipotentiale verbindingen en automatische uitschakeling onderbouwd door metingen;",[137,1901,1902],{},"duidelijke identificatie van kringen en beveiligingstoestellen;",[137,1904,1905],{},"kabelkeuze en mechanische bescherming passend bij de plaatsingswijze;",[137,1907,1908],{},"regels voor bijzondere ruimten, inclusief werkelijke badkamergeometrie;",[137,1910,1911],{},"hoofdschakeling en scheiding passend bij de installatie;",[137,1913,1914],{},"coördinatie van geleider, plaatsingsvoorwaarden en overstroombeveiliging;",[137,1916,1917],{},"expliciete projectbeoordeling van overspanningsbeveiliging;",[137,1919,1920],{},"scheiding van AREI-vaststellingen en regionale woonplichten zoals rookmelders.",[11,1922,1923],{},"De precieze vaststelling en het actuele Boek 1 bepalen wat moet worden gecorrigeerd. Een lijst vervangt diagnose, metingen of verslag niet.",[22,1925,1927],{"id":1926},"onduidelijke-vaststellingen-schriftelijk-verduidelijken","Onduidelijke vaststellingen schriftelijk verduidelijken",[11,1929,1930],{},"Formuleer een vraag met verslagnummer, letterlijke vaststelling, kringreferentie en concrete onduidelijkheid. Vraag niet alleen “wat moet ik kopen?”, maar welke beschermingsfunctie of documentinformatie ontbreekt en welk bewijs bij de volgende controle wordt verwacht. Zo vermijdt u dat een aannemer een zichtbaar onderdeel vervangt terwijl de onderliggende oorzaak ongewijzigd blijft.",[11,1932,1933],{},"Bewaar antwoord en verslag samen. Een telefonische toelichting kan nuttig zijn, maar een schriftelijke bevestiging maakt later duidelijk welke situatie werd besproken. Wijzigt de geplande oplossing de verdeling, aardingswijze, bron of vaste bedrading, laat dan ook de gevolgen voor andere kringen en plannen beoordelen.",[11,1935,1936],{},"Kies bij offertes één omschrijving van de vaststellingen en laat iedere aanbieder dezelfde scope opnemen: diagnose, uitvoering, metingen, documentatie en voorbereiding van de nieuwe controle. Vermeld wie de plannen na uitvoering bijwerkt. De goedkoopste losse component is niet noodzakelijk de goedkoopste volledige oplossing wanneer metingen of tweede werkzaamheden ontbreken.",[11,1938,1939],{},"Controleer tenslotte of het keuringsorganisme extra stukken vraagt voor bijzondere apparatuur. Een batterij, PV-installatie, laadpaal of noodstroomfunctie kan fabrikantdocumentatie en een duidelijk beschreven bedrijfsmodus vereisen. Voeg alleen stukken toe die bij het werkelijk geplaatste model horen.",[22,1941,1943],{"id":1942},"stap-voor-stap-na-de-negatieve-keuring","Stap voor stap: na de negatieve keuring",[34,1945,1947],{"id":1946},"stap-1-verslag-zorgvuldig-lezen","Stap 1: Verslag zorgvuldig lezen",[11,1949,1950],{},"Ga elke inbreuk apart door. Noteer:",[185,1952,1953,1956,1959],{},[137,1954,1955],{},"Welke categorie en legende gebruikt het verslag?",[137,1957,1958],{},"Waar is het probleem precies (kamer, stroomkring)?",[137,1960,1961],{},"Wat wordt er precies betwist?",[34,1963,1965],{"id":1964},"stap-2-prioriteiten-stellen","Stap 2: Prioriteiten stellen",[11,1967,1968],{},"Begin met elke vaststelling die het verslag als onmiddellijk gevaar, reden tot uitschakeling of hinderpaal voor ingebruikname aanduidt. Rangschik daarna op afhankelijkheid: oorzaak en beveiligingsconcept, uitvoering, meting en documentatie.",[34,1970,1972],{"id":1971},"stap-3-vakman-of-zelf","Stap 3: Vakman of zelf?",[11,1974,1975,1976,213],{},"U kunt het verslag ordenen, documenten verzamelen en plannen met zichtbaar materieel vergelijken. Of u een correctie zelf veilig mag uitvoeren, hangt van werk en deskundigheid af. Werk in het bord of aan beveiliging, aarding en vaste leidingen hoort bij een ",[14,1977,1978],{},"elektrisch vakpersoon",[185,1980,1981,1984,1987,1990],{},[137,1982,1983],{},"Differentieel bijplaatsen of vervangen",[137,1985,1986],{},"Aarding verbeteren",[137,1988,1989],{},"Kabels in beschermbuizen leggen",[137,1991,1992],{},"Hoofdschakelaar installeren",[34,1994,1996],{"id":1995},"stap-4-plannen-bijwerken","Stap 4: Plannen bijwerken",[11,1998,1999,2000,2003],{},"Eendraadschema en situatieplan moeten ",[14,2001,2002],{},"de huidige toestand"," weerspiegelen. Verzin geen geleiderdoorsneden of nominale waarden. Laat onbekende kenmerken vóór export bepalen of markeer ze duidelijk als open.",[34,2005,2007],{"id":2006},"stap-5-herkeuring-afspreken","Stap 5: Herkeuring afspreken",[11,2009,2010],{},"Het bevoegde organisme hangt van de procedure af. De aanvullende controle na een negatieve periodieke keuring gebeurt door hetzelfde organisme. Na de relevante negatieve verkoopkeuring mag de koper in beginsel een erkend organisme kiezen en wordt de volledige installatie opnieuw bekeken. Bevestig de scope vóór reservatie.",[22,2012,2014],{"id":2013},"budgetteren-zonder-schijnprecisie","Budgetteren zonder schijnprecisie",[11,2016,2017],{},"Tarieven en herstelkosten hangen af van procedure, organisme, verplaatsing, aantal borden, metingen en het werkelijke defect. Vraag het actuele tarief rechtstreeks. Een herstelofferte splitst diagnose, materiaal, arbeid, metingen, planwijziging en nieuwe controle uit. Een vaste online prijsvork kan een verborgen leidingfout of verbouwing van het bord niet weergeven.",[22,2019,2021],{"id":2020},"bewijs-voor-de-nieuwe-controle-opbouwen","Bewijs voor de nieuwe controle opbouwen",[11,2023,2024],{},"Houd per vaststelling één regel bij: verslagtekst, betrokken kring, actie, verantwoordelijke, voltooiingsdatum en bewijs. Foto's vullen aan maar vervangen geen meting. Werk de plannen na de echte uitvoering bij en vergelijk daarna labels en referenties opnieuw.",[11,2026,2027,2028,2032,2033,2037,2038,1566],{},"De officiële ",[264,2029,2031],{"href":266,"rel":2030},[268],"pagina over soorten huishoudelijke controles"," beschrijft gevolgen en termijnen. De ",[264,2034,2036],{"href":273,"rel":2035},[268],"federale verkoop-FAQ"," behandelt de achttien maanden en keuze van organisme. Gebruik ook de ",[264,2039,2041],{"href":279,"rel":2040},[268],"officiële lijst van erkende organismen",[22,2043,2045],{"id":2044},"zet-elke-vaststelling-om-in-een-controleerbare-actie","Zet elke vaststelling om in een controleerbare actie",[11,2047,2048],{},"Een verslag beschrijft vaak een resultaat, niet automatisch de technische oorzaak. Onvoldoende isolatieweerstand kan komen door een beschadigde geleider, vocht, aangesloten apparatuur of een combinatie. “Plan stemt niet overeen” kan gaan van een ontbrekend stopcontact tot een verkeerde volgorde van beveiligingstoestellen. Bestel dus niet meteen één onderdeel, maar bepaal oorzaak en getroffen scope.",[11,2050,2051],{},"Stel per vaststelling vijf vragen:",[134,2053,2054,2057,2060,2063,2066],{},[137,2055,2056],{},"welk installatiedeel werd werkelijk gecontroleerd?",[137,2058,2059],{},"welke regel of beveiligingsfunctie is getroffen?",[137,2061,2062],{},"welke diagnose of meting bevestigt de oorzaak?",[137,2064,2065],{},"welke correctie verwijdert de oorzaak in plaats van alleen het symptoom?",[137,2067,2068],{},"welk bewijs maakt de voltooide correctie voor het organisme verifieerbaar?",[11,2070,2071],{},"Vaststellingen kunnen samenhangen. Een wijziging aan het bord beïnvloedt eendraadschema, labels, beveiligingen en mogelijk metingen. Aardingswerk moet klaar zijn vóór definitieve plannen en nieuwe meting. Werk naar één consistente eindtoestand in plaats van tegenstrijdige tussenstanden te documenteren.",[22,2073,2075],{"id":2074},"scheid-documentatie-en-uitvoeringsgebreken","Scheid documentatie- en uitvoeringsgebreken",[11,2077,2078],{},"Een ontbrekend plan wordt niet opgelost door onbevestigde aannames te tekenen. Inventariseer de installatie eerst; openen en meten hoort alleen bij iemand die dat veilig en deskundig kan. Koppel daarna elk symbool aan de werkelijke kring en bevestig dat bord, eendraadschema en situatieplan dezelfde referentie gebruiken.",[11,2080,2081],{},"Een fysiek gebrek verdwijnt niet met een betere tekening. Is een beveiliging ongeschikt, de aarding onvoldoende of een leiding mechanisch bedreigd, dan moet de installatie worden gecorrigeerd en zo nodig opnieuw gemeten. Werk pas daarna de plannen bij. Zo vindt de nieuwe controle geen actuele documenten naast hetzelfde oude gevaar.",[22,2083,2085],{"id":2084},"bijzondere-verkoopsituatie","Bijzondere verkoopsituatie",[11,2087,2088],{},"Bewaar na een negatieve verkoopkeuring verslag, authentieke akte en dossier samen. De achttien maanden lopen vanaf de authentieke akte. De koper deelt identiteit en aktedatum mee aan het oorspronkelijke organisme. Kiest hij voor de nieuwe controle een ander erkend organisme, dan informeert dit volgens de federale uitleg het eerste.",[11,2090,2091],{},"De termijn is geen toestemming om een zichtbaar gevaar te laten bestaan. Laat onveilige delen snel beoordelen en indien nodig buiten gebruik stellen. Doorverkoop, totaalrenovatie of afbraak binnen de termijn kan de procedure wijzigen; gebruik daarvoor de federale FAQ en de concrete notariële situatie.",[22,2093,2095],{"id":2094},"laatste-controle-vóór-de-afspraak","Laatste controle vóór de afspraak",[185,2097,2098,2101,2104,2107,2110,2113,2116],{},[137,2099,2100],{},"Elke vaststelling is aan een voltooide actie gekoppeld.",[137,2102,2103],{},"Correcties met meetplicht hebben gedocumenteerde resultaten.",[137,2105,2106],{},"Kringreferenties stemmen overeen in bord en beide plannen.",[137,2108,2109],{},"Toegevoegde en verwijderde toestellen staan op het situatieplan.",[137,2111,2112],{},"Nominale waarden en kabelgegevens passen bij de uitvoering.",[137,2114,2115],{},"Juiste organisme en controletype zijn bevestigd.",[137,2117,2118],{},"Verslag, plannen, EAN-code en fabrikantstukken liggen klaar.",[11,2120,2121],{},"Dit belooft geen positief verslag. Het voorkomt wel dat een uitgevoerde herstelling door tegenstrijdige documenten niet controleerbaar is.",[11,2123,2124],{},"Voorzie ook tijd voor vragen en eventueel een tweede diagnose. Pas wanneer oorzaak, uitvoering en bewijs bij elkaar passen, is de vaststelling werkelijk afgehandeld; alleen een vinkje in een takenlijst volstaat niet.",[11,2126,2127],{},"Archiveer bij de afspraak exact de planversie die werd voorgelegd en koppel ze aan het uiteindelijke verslag. Noteer schriftelijke verduidelijkingen van het keuringsorganisme bij de betrokken vaststelling, zodat een latere wijziging niet met de beoordeelde toestand wordt verward.",[22,2129,2131],{"id":2130},"hoe-planelec-helpt","Hoe PlanElec helpt",[11,2133,2134,2135,2138],{},"De PlanElec-zelfcontrole kan enkele ondersteunde planningsproblemen ",[14,2136,2137],{},"vóór de keuring"," signaleren:",[185,2140,2141,2147,2153,2159],{},[137,2142,2143,2146],{},[14,2144,2145],{},"Validatie"," signaleert ondersteunde gegevens over differentielen en beveiliging",[137,2148,2149,2152],{},[14,2150,2151],{},"Eendraadschema"," geeft de ingevoerde topologie consistent weer",[137,2154,2155,2158],{},[14,2156,2157],{},"Situatieplan"," gebruikt de ondersteunde Belgische symbolenbibliotheek",[137,2160,2161,2164],{},[14,2162,2163],{},"Etikettering"," van alle stroomkringen wordt automatisch in het schema gedocumenteerd",[11,2166,2167],{},"De zelfcontrole is geen attest, voert geen metingen uit en garandeert geen positief resultaat. Ze ondersteunt een consistent dossier voor professionele beoordeling.",[410,2169],{},[11,2171,2172],{},[14,2173,2174],{},"Gerelateerde artikelen:",[185,2176,2177,2183,2189],{},[137,2178,2179],{},[264,2180,2182],{"href":2181},"\u002Fblog\u002F10-meest-voorkomende-arei-overtredingen","De 10 meest voorkomende AREI-overtredingen",[137,2184,2185],{},[264,2186,2188],{"href":2187},"\u002Fblog\u002F30ma-differentieel","30 mA differentieel: Wanneer is het verplicht?",[137,2190,2191],{},[264,2192,2194],{"href":2193},"\u002Fblog\u002Fkabeldoorsnede-zekering","Kabeldoorsnede en zekering: De juiste combinatie",[11,2196,2197,442,2200],{},[14,2198,2199],{},"Bereid uw elektrische plannen voor met PlanElec en gebruik de zelfcontrole als hulp vóór professionele beoordeling en de officiële keuring.",[264,2201,2203],{"href":445,"rel":2202},[268],"Nu starten →",{"title":449,"searchDepth":450,"depth":450,"links":2205},[2206,2209,2214,2215,2216,2223,2224,2225,2226,2227,2228,2229],{"id":1787,"depth":450,"text":1788,"children":2207},[2208],{"id":1798,"depth":455,"text":1799},{"id":1851,"depth":450,"text":1852,"children":2210},[2211,2212,2213],{"id":1855,"depth":455,"text":1856},{"id":1866,"depth":455,"text":1867},{"id":1873,"depth":455,"text":1874},{"id":1884,"depth":450,"text":1885},{"id":1926,"depth":450,"text":1927},{"id":1942,"depth":450,"text":1943,"children":2217},[2218,2219,2220,2221,2222],{"id":1946,"depth":455,"text":1947},{"id":1964,"depth":455,"text":1965},{"id":1971,"depth":455,"text":1972},{"id":1995,"depth":455,"text":1996},{"id":2006,"depth":455,"text":2007},{"id":2013,"depth":450,"text":2014},{"id":2020,"depth":450,"text":2021},{"id":2044,"depth":450,"text":2045},{"id":2074,"depth":450,"text":2075},{"id":2084,"depth":450,"text":2085},{"id":2094,"depth":450,"text":2095},{"id":2130,"depth":450,"text":2131},"Is uw elektrokeuring negatief? Lees hoe u het verslag beoordeelt, de juiste termijn bepaalt, veilige correcties plant en de nieuwe controle voorbereidt.","nl",{},"\u002Fblog\u002Finspection-failed-what-now.nl",{"title":1773,"description":2230},"elektrokeuring-afgekeurd","blog\u002Finspection-failed-what-now.nl",[999,2238,2239,2240,2241,496,2242],"elektrokeuring","afgekeurd","inbreuken","herkeuring","belgie","RQ092-Mffn3f1DXospOyJh-mLjtyNv17FN2YGyppNM0",1788389263070]