[{"data":1,"prerenderedAt":1268},["ShallowReactive",2],{"blog-post-de-was-ist-ein-situationsplan":3,"blog-alternates-what-is-a-situation-plan":305},{"id":4,"title":5,"articleId":6,"body":7,"category":280,"date":281,"description":282,"extension":283,"lastUpdated":284,"locale":285,"meta":286,"navigation":287,"path":288,"publishDate":281,"readTime":289,"refreshInterval":290,"seo":291,"slug":292,"stem":293,"tags":294,"__hash__":304},"blog\u002Fblog\u002Fwhat-is-a-situation-plan.de.md","Was ist ein Situationsplan?","what-is-a-situation-plan",{"type":8,"value":9,"toc":268},"minimark",[10,15,33,40,44,61,110,113,117,122,157,161,241,244,248,262],[11,12,14],"h2",{"id":13},"ein-grundriss-ihrer-elektroinstallation","Ein Grundriss Ihrer Elektroinstallation",[16,17,18,19,23,24,27,28,32],"p",{},"Der Situationsplan (niederländisch: ",[20,21,22],"em",{},"situatieschema",", französisch: ",[20,25,26],{},"plan de situation",") ist ein vereinfachter Grundriss Ihres Gebäudes, auf dem die ",[29,30,31],"strong",{},"physische Position"," der relevanten elektrischen Komponenten eingezeichnet ist — etwa Steckdosen, Schalter, Leuchten, Verteiler und feste Geräte. Ein bestimmter Maßstab ist nicht pauschal vorgeschrieben; der Plan muss vor allem lesbar und eindeutig sein.",[16,34,35,36,39],{},"Anders als das Eindrahtschema zeigt der Situationsplan nicht die logische Schaltungshierarchie, sondern ",[29,37,38],{},"wo genau"," sich alles befindet.",[11,41,43],{"id":42},"was-sagt-das-arei","Was sagt das AREI?",[16,45,46,47,54,55,60],{},"Die ",[48,49,53],"a",{"href":50,"rel":51},"https:\u002F\u002Feconomie.fgov.be\u002Ffr\u002Fthemes\u002Fenergie\u002Fsources-et-vecteurs-denergie\u002Felectricite\u002Fsecurite-et-controle-des\u002Fcontrole-des-installations",[52],"nofollow","offizielle Übersicht des SPF Economie zur häuslichen Elektrokontrolle"," nennt Eindrahtschema und Situationsplan als mindestens vorzulegende Unterlagen. Das aktuelle ",[48,56,59],{"href":57,"rel":58},"https:\u002F\u002Feconomie.fgov.be\u002Fsites\u002Fdefault\u002Ffiles\u002FFiles\u002FPublications\u002Ffiles\u002FRGIE-Annexe-Livre-1-Installations-a-basse-tenstion-et-a-tres-basse-tension-2026.pdf",[52],"AREI\u002FRGIE Buch 1"," beschreibt Inhalt und gemeinsame Referenzen:",[62,63,64,80],"table",{},[65,66,67],"thead",{},[68,69,70,74,77],"tr",{},[71,72,73],"th",{},"Dokument",[71,75,76],{},"AREI-Artikel",[71,78,79],{},"Zeigt",[81,82,83,97],"tbody",{},[68,84,85,91,94],{},[86,87,88],"td",{},[29,89,90],{},"Eindrahtschema",[86,92,93],{},"Art. 9.1.2 Nr. 1",[86,95,96],{},"Logische Struktur — Schutzgeräte, Stromkreise, Hierarchie",[68,98,99,104,107],{},[86,100,101],{},[29,102,103],{},"Situationsplan",[86,105,106],{},"Art. 9.1.2 Nr. 2",[86,108,109],{},"Physische Position — wo ist alles im Gebäude installiert, inkl. Lage des Zählerkastens und der Erdungsanlage",[16,111,112],{},"Die Unterlagen müssen den tatsächlichen Zustand wiedergeben. Fehlende oder widersprüchliche Pläne können als Verstoß im Kontrollbericht erscheinen; den offiziellen Befund stellt allein der zugelassene Kontrollorganismus fest.",[11,114,116],{"id":115},"was-muss-auf-den-situationsplan","Was muss auf den Situationsplan?",[118,119,121],"h3",{"id":120},"checkliste","Checkliste",[123,124,125,129,132,135,138,141,144,147,154],"ul",{},[126,127,128],"li",{},"Lesbarer, vereinfachter Grundriss jeder betroffenen Etage",[126,130,131],{},"Position aller Steckdosen (Einzel, Doppel, mit Erdung)",[126,133,134],{},"Position aller Schalter (Ein\u002FAus, Wechsel, Dimmer)",[126,136,137],{},"Beleuchtungspunkte (Decke, Wand, Außen)",[126,139,140],{},"Verteilerkasten und Zählerposition",[126,142,143],{},"Festanschlussgeräte (Kochfeld, Boiler, Wallbox)",[126,145,146],{},"Eindeutige Lage der im Eindrahtschema genannten Betriebsmittel",[126,148,149,150,153],{},"Stromkreis-Referenznummern (die Nummerierung muss zwischen Situationsplan und Eindrahtschema ",[29,151,152],{},"identisch"," sein)",[126,155,156],{},"Passende Symbole aus AREI\u002FRGIE Tabelle 2.23 (Kapitel 2.13)",[11,158,160],{"id":159},"situationsplan-vs-eindrahtschema","Situationsplan vs. Eindrahtschema",[62,162,163,174],{},[65,164,165],{},[68,166,167,170,172],{},[71,168,169],{},"Eigenschaft",[71,171,103],{},[71,173,90],{},[81,175,176,187,198,208,219,230],{},[68,177,178,181,184],{},[86,179,180],{},"Darstellung",[86,182,183],{},"Physischer Grundriss",[86,185,186],{},"Logisches Schaltbild",[68,188,189,192,195],{},[86,190,191],{},"Zeigt Position?",[86,193,194],{},"Ja — wo genau",[86,196,197],{},"Nein",[68,199,200,203,205],{},[86,201,202],{},"Zeigt Hierarchie?",[86,204,197],{},[86,206,207],{},"Ja — vom Netz bis zum Verbraucher",[68,209,210,213,216],{},[86,211,212],{},"Schutzgeräte",[86,214,215],{},"Nur Position",[86,217,218],{},"Nennwerte, Typ, Koordination",[68,220,221,224,227],{},[86,222,223],{},"Kabelangaben",[86,225,226],{},"Verläufe sichtbar",[86,228,229],{},"Typ und Querschnitt angegeben",[68,231,232,235,238],{},[86,233,234],{},"Maßstab",[86,236,237],{},"Nicht pauschal vorgegeben; lesbar und eindeutig",[86,239,240],{},"Nicht maßstäblich",[16,242,243],{},"Beide Dokumente ergänzen sich und sind gleichermaßen Pflicht.",[11,245,247],{"id":246},"verwandte-artikel","Verwandte Artikel",[123,249,250,256],{},[126,251,252],{},[48,253,255],{"href":254},"\u002Fde\u002Fblog\u002Feindrahtschema-erstellen","Eindrahtschema selbst erstellen — Schritt für Schritt",[126,257,258],{},[48,259,261],{"href":260},"\u002Fde\u002Fblog\u002Felektroplan-kosten","Was kostet ein Elektroplan in Belgien?",[16,263,264],{},[48,265,267],{"href":266},"\u002F","Erstellen Sie jetzt Ihren Situationsplan mit PlanElec — kostenlos →",{"title":269,"searchDepth":270,"depth":270,"links":271},"",2,[272,273,274,278,279],{"id":13,"depth":270,"text":14},{"id":42,"depth":270,"text":43},{"id":115,"depth":270,"text":116,"children":275},[276],{"id":120,"depth":277,"text":121},3,{"id":159,"depth":270,"text":160},{"id":246,"depth":270,"text":247},"faq","2026-03-06","Der Situationsplan zeigt, wo alle elektrischen Komponenten in Ihrem Gebäude physisch installiert sind. Erfahren Sie, was drauf muss und wie er sich vom Eindrahtschema unterscheidet.","md","2026-08-29","de",{},true,"\u002Fblog\u002Fwhat-is-a-situation-plan.de","3 min",12,{"title":5,"description":282},"was-ist-ein-situationsplan","blog\u002Fwhat-is-a-situation-plan.de",[295,296,103,22,26,297,90,298,299,300,301,302,303],"AREI","RGIE","situation plan","Eendraadschema","schéma unifilaire","Stromabnahme","Keuring","Grundriss","Belgien","zF0HlnER8EfaDeyGlgElnlbLSqOUhslAS7U9UO0nJnk",[306,489,753,1010],{"id":4,"title":5,"articleId":6,"body":307,"category":280,"date":281,"description":282,"extension":283,"lastUpdated":284,"locale":285,"meta":486,"navigation":287,"path":288,"publishDate":281,"readTime":289,"refreshInterval":290,"seo":487,"slug":292,"stem":293,"tags":488,"__hash__":304},{"type":8,"value":308,"toc":477},[309,311,319,323,325,333,367,369,371,373,395,397,459,461,463,473],[11,310,14],{"id":13},[16,312,18,313,23,315,27,317,32],{},[20,314,22],{},[20,316,26],{},[29,318,31],{},[16,320,35,321,39],{},[29,322,38],{},[11,324,43],{"id":42},[16,326,46,327,54,330,60],{},[48,328,53],{"href":50,"rel":329},[52],[48,331,59],{"href":57,"rel":332},[52],[62,334,335,345],{},[65,336,337],{},[68,338,339,341,343],{},[71,340,73],{},[71,342,76],{},[71,344,79],{},[81,346,347,357],{},[68,348,349,353,355],{},[86,350,351],{},[29,352,90],{},[86,354,93],{},[86,356,96],{},[68,358,359,363,365],{},[86,360,361],{},[29,362,103],{},[86,364,106],{},[86,366,109],{},[16,368,112],{},[11,370,116],{"id":115},[118,372,121],{"id":120},[123,374,375,377,379,381,383,385,387,389,393],{},[126,376,128],{},[126,378,131],{},[126,380,134],{},[126,382,137],{},[126,384,140],{},[126,386,143],{},[126,388,146],{},[126,390,149,391,153],{},[29,392,152],{},[126,394,156],{},[11,396,160],{"id":159},[62,398,399,409],{},[65,400,401],{},[68,402,403,405,407],{},[71,404,169],{},[71,406,103],{},[71,408,90],{},[81,410,411,419,427,435,443,451],{},[68,412,413,415,417],{},[86,414,180],{},[86,416,183],{},[86,418,186],{},[68,420,421,423,425],{},[86,422,191],{},[86,424,194],{},[86,426,197],{},[68,428,429,431,433],{},[86,430,202],{},[86,432,197],{},[86,434,207],{},[68,436,437,439,441],{},[86,438,212],{},[86,440,215],{},[86,442,218],{},[68,444,445,447,449],{},[86,446,223],{},[86,448,226],{},[86,450,229],{},[68,452,453,455,457],{},[86,454,234],{},[86,456,237],{},[86,458,240],{},[16,460,243],{},[11,462,247],{"id":246},[123,464,465,469],{},[126,466,467],{},[48,468,255],{"href":254},[126,470,471],{},[48,472,261],{"href":260},[16,474,475],{},[48,476,267],{"href":266},{"title":269,"searchDepth":270,"depth":270,"links":478},[479,480,481,484,485],{"id":13,"depth":270,"text":14},{"id":42,"depth":270,"text":43},{"id":115,"depth":270,"text":116,"children":482},[483],{"id":120,"depth":277,"text":121},{"id":159,"depth":270,"text":160},{"id":246,"depth":270,"text":247},{},{"title":5,"description":282},[295,296,103,22,26,297,90,298,299,300,301,302,303],{"id":490,"title":491,"articleId":6,"body":492,"category":280,"date":281,"description":739,"extension":283,"lastUpdated":284,"locale":740,"meta":741,"navigation":287,"path":742,"publishDate":281,"readTime":289,"refreshInterval":290,"seo":743,"slug":6,"stem":744,"tags":745,"__hash__":752},"blog\u002Fblog\u002Fwhat-is-a-situation-plan.en.md","What Is a Situation Plan?",{"type":8,"value":493,"toc":730},[494,498,511,518,522,535,576,579,583,587,620,624,704,707,711,725],[11,495,497],{"id":496},"a-floor-plan-of-your-electrical-installation","A floor plan of your electrical installation",[16,499,500,501,503,504,506,507,510],{},"A situation plan (Dutch: ",[20,502,22],{},", French: ",[20,505,26],{},") is a simplified floor plan showing the ",[29,508,509],{},"physical location"," of relevant electrical equipment — such as sockets, switches, lights, distribution boards and fixed appliances. No universal drawing scale is prescribed; clarity and unambiguous locations matter.",[16,512,513,514,517],{},"Unlike a single-line diagram, the situation plan doesn't show the logical circuit hierarchy, but rather ",[29,515,516],{},"exactly where"," everything is located.",[11,519,521],{"id":520},"what-does-the-arei-say","What does the AREI say?",[16,523,524,525,529,530,534],{},"The Federal Public Service Economy's ",[48,526,528],{"href":50,"rel":527},[52],"official domestic-inspection guidance"," lists the single-line diagram and situation plan among the minimum documents to provide. The current ",[48,531,533],{"href":57,"rel":532},[52],"AREI\u002FRGIE Book 1"," defines their content and shared references:",[62,536,537,550],{},[65,538,539],{},[68,540,541,544,547],{},[71,542,543],{},"Document",[71,545,546],{},"AREI Article",[71,548,549],{},"Shows",[81,551,552,564],{},[68,553,554,559,561],{},[86,555,556],{},[29,557,558],{},"Single-line diagram",[86,560,93],{},[86,562,563],{},"Logical structure — protection devices, circuits, hierarchy",[68,565,566,571,573],{},[86,567,568],{},[29,569,570],{},"Situation plan",[86,572,106],{},[86,574,575],{},"Physical location — where everything is installed in the building, incl. location of the meter board and earthing system",[16,577,578],{},"The documents must reflect the real installation. Missing or inconsistent plans may be recorded as an infringement; only the approved inspection body determines the official outcome.",[11,580,582],{"id":581},"what-must-be-on-the-situation-plan","What must be on the situation plan?",[118,584,586],{"id":585},"checklist","Checklist",[123,588,589,592,595,598,601,604,607,610,617],{},[126,590,591],{},"Clear, simplified floor plan of each relevant storey",[126,593,594],{},"Position of all sockets (single, double, earthed)",[126,596,597],{},"Position of all switches (on\u002Foff, two-way, dimmer)",[126,599,600],{},"Lighting points (ceiling, wall, outdoor)",[126,602,603],{},"Distribution board and meter location",[126,605,606],{},"Fixed appliances (hob, boiler, EV charger)",[126,608,609],{},"Unambiguous locations for the equipment referenced on the single-line diagram",[126,611,612,613,616],{},"Circuit reference numbers (numbering must be ",[29,614,615],{},"identical"," between situation plan and single-line diagram)",[126,618,619],{},"Appropriate symbols from AREI\u002FRGIE Table 2.23 (Chapter 2.13)",[11,621,623],{"id":622},"situation-plan-vs-single-line-diagram","Situation plan vs. single-line diagram",[62,625,626,637],{},[65,627,628],{},[68,629,630,633,635],{},[71,631,632],{},"Property",[71,634,570],{},[71,636,558],{},[81,638,639,650,661,671,682,693],{},[68,640,641,644,647],{},[86,642,643],{},"Representation",[86,645,646],{},"Physical floor plan",[86,648,649],{},"Logical circuit diagram",[68,651,652,655,658],{},[86,653,654],{},"Shows position?",[86,656,657],{},"Yes — exact location",[86,659,660],{},"No",[68,662,663,666,668],{},[86,664,665],{},"Shows hierarchy?",[86,667,660],{},[86,669,670],{},"Yes — from grid to consumer",[68,672,673,676,679],{},[86,674,675],{},"Protection devices",[86,677,678],{},"Position only",[86,680,681],{},"Ratings, type, coordination",[68,683,684,687,690],{},[86,685,686],{},"Cable info",[86,688,689],{},"Routes visible",[86,691,692],{},"Type and cross-section listed",[68,694,695,698,701],{},[86,696,697],{},"Scaled",[86,699,700],{},"No universal scale; clear and unambiguous",[86,702,703],{},"Not to scale",[16,705,706],{},"Both documents complement each other and are equally mandatory.",[11,708,710],{"id":709},"related-articles","Related articles",[123,712,713,719],{},[126,714,715],{},[48,716,718],{"href":717},"\u002Fen\u002Fblog\u002Fsingle-line-diagram","How to create a single-line diagram — step by step",[126,720,721],{},[48,722,724],{"href":723},"\u002Fen\u002Fblog\u002Felectrical-plan-costs","How much does an electrical plan cost in Belgium?",[16,726,727],{},[48,728,729],{"href":266},"Create your situation plan with PlanElec now — free →",{"title":269,"searchDepth":270,"depth":270,"links":731},[732,733,734,737,738],{"id":496,"depth":270,"text":497},{"id":520,"depth":270,"text":521},{"id":581,"depth":270,"text":582,"children":735},[736],{"id":585,"depth":277,"text":586},{"id":622,"depth":270,"text":623},{"id":709,"depth":270,"text":710},"A situation plan shows where all electrical components are physically installed in your building. Learn what it must include and how it differs from a single-line diagram.","en",{},"\u002Fblog\u002Fwhat-is-a-situation-plan.en",{"title":491,"description":739},"blog\u002Fwhat-is-a-situation-plan.en",[295,296,297,22,103,26,746,747,90,299,748,749,750,751],"single-line diagram","eendraadschema","inspection","keuring","floor plan","Belgium","Sl_CbBTNKJDErh1j4L7pwbtQxJMic81QjWr0KyapMbw",{"id":754,"title":755,"articleId":6,"body":756,"category":280,"date":281,"description":998,"extension":283,"lastUpdated":284,"locale":999,"meta":1000,"navigation":287,"path":1001,"publishDate":281,"readTime":289,"refreshInterval":290,"seo":1002,"slug":1003,"stem":1004,"tags":1005,"__hash__":1009},"blog\u002Fblog\u002Fwhat-is-a-situation-plan.fr.md","Qu'est-ce qu'un plan de situation ?",{"type":8,"value":757,"toc":989},[758,762,775,782,786,799,839,842,846,850,879,883,963,966,970,984],[11,759,761],{"id":760},"un-plan-au-sol-de-votre-installation-électrique","Un plan au sol de votre installation électrique",[16,763,764,765,767,768,770,771,774],{},"Le plan de situation (néerlandais : ",[20,766,22],{},", allemand : ",[20,769,103],{},") est un plan simplifié du bâtiment montrant la ",[29,772,773],{},"position physique"," du matériel électrique pertinent — prises, interrupteurs, luminaires, tableaux et appareils fixes. Aucune échelle universelle n'est imposée ; la lisibilité et l'absence d'ambiguïté sont essentielles.",[16,776,777,778,781],{},"Contrairement au schéma unifilaire, le plan de situation ne montre pas la hiérarchie logique des circuits, mais ",[29,779,780],{},"où exactement"," tout se trouve.",[11,783,785],{"id":784},"que-dit-le-rgie","Que dit le RGIE ?",[16,787,788,789,793,794,798],{},"La ",[48,790,792],{"href":50,"rel":791},[52],"page officielle du SPF Economie sur le contrôle domestique"," cite le schéma unifilaire et le plan de situation parmi les documents à remettre au minimum. Le ",[48,795,797],{"href":57,"rel":796},[52],"Livre 1 du RGIE en vigueur"," précise leur contenu et leurs repères communs :",[62,800,801,813],{},[65,802,803],{},[68,804,805,807,810],{},[71,806,543],{},[71,808,809],{},"Article RGIE",[71,811,812],{},"Montre",[81,814,815,827],{},[68,816,817,822,824],{},[86,818,819],{},[29,820,821],{},"Schéma unifilaire",[86,823,93],{},[86,825,826],{},"Structure logique — dispositifs de protection, circuits, hiérarchie",[68,828,829,834,836],{},[86,830,831],{},[29,832,833],{},"Plan de situation",[86,835,106],{},[86,837,838],{},"Position physique — où tout est installé dans le bâtiment, y compris l'emplacement du compteur et du système de mise à la terre",[16,840,841],{},"Les documents doivent correspondre à l'installation réelle. Des plans absents ou contradictoires peuvent être repris comme infraction ; seul l'organisme agréé établit la conclusion officielle.",[11,843,845],{"id":844},"que-doit-contenir-le-plan-de-situation","Que doit contenir le plan de situation ?",[118,847,849],{"id":848},"liste-de-vérification","Liste de vérification",[123,851,852,855,858,861,864,867,870,873,876],{},[126,853,854],{},"Plan simplifié et lisible de chaque étage concerné",[126,856,857],{},"Position de toutes les prises (simple, double, avec terre)",[126,859,860],{},"Position de tous les interrupteurs (on\u002Foff, va-et-vient, variateur)",[126,862,863],{},"Points lumineux (plafond, mur, extérieur)",[126,865,866],{},"Tableau de distribution et emplacement du compteur",[126,868,869],{},"Appareils fixes (plaque de cuisson, chauffe-eau, borne de recharge)",[126,871,872],{},"Emplacement non ambigu du matériel référencé au schéma unifilaire",[126,874,875],{},"Numéros de référence des circuits (doivent correspondre au schéma unifilaire)",[126,877,878],{},"Symboles appropriés du tableau 2.23 du RGIE (chapitre 2.13)",[11,880,882],{"id":881},"plan-de-situation-vs-schéma-unifilaire","Plan de situation vs. schéma unifilaire",[62,884,885,896],{},[65,886,887],{},[68,888,889,892,894],{},[71,890,891],{},"Propriété",[71,893,833],{},[71,895,821],{},[81,897,898,909,920,930,941,952],{},[68,899,900,903,906],{},[86,901,902],{},"Représentation",[86,904,905],{},"Plan au sol physique",[86,907,908],{},"Schéma logique des circuits",[68,910,911,914,917],{},[86,912,913],{},"Montre la position ?",[86,915,916],{},"Oui — emplacement exact",[86,918,919],{},"Non",[68,921,922,925,927],{},[86,923,924],{},"Montre la hiérarchie ?",[86,926,919],{},[86,928,929],{},"Oui — du réseau au consommateur",[68,931,932,935,938],{},[86,933,934],{},"Dispositifs de protection",[86,936,937],{},"Position uniquement",[86,939,940],{},"Calibres, type, coordination",[68,942,943,946,949],{},[86,944,945],{},"Info câbles",[86,947,948],{},"Chemins visibles",[86,950,951],{},"Type et section indiqués",[68,953,954,957,960],{},[86,955,956],{},"À l'échelle",[86,958,959],{},"Pas d'échelle universelle ; lisible et sans ambiguïté",[86,961,962],{},"Non coté à l'échelle",[16,964,965],{},"Les deux documents se complètent et sont également obligatoires.",[11,967,969],{"id":968},"articles-connexes","Articles connexes",[123,971,972,978],{},[126,973,974],{},[48,975,977],{"href":976},"\u002Ffr\u002Fblog\u002Fschema-unifilaire","Créer un schéma unifilaire — étape par étape",[126,979,980],{},[48,981,983],{"href":982},"\u002Ffr\u002Fblog\u002Fcout-plan-electrique","Combien coûte un plan électrique en Belgique ?",[16,985,986],{},[48,987,988],{"href":266},"Créez votre plan de situation avec PlanElec — gratuit →",{"title":269,"searchDepth":270,"depth":270,"links":990},[991,992,993,996,997],{"id":760,"depth":270,"text":761},{"id":784,"depth":270,"text":785},{"id":844,"depth":270,"text":845,"children":994},[995],{"id":848,"depth":277,"text":849},{"id":881,"depth":270,"text":882},{"id":968,"depth":270,"text":969},"Le plan de situation montre où tous les composants électriques sont physiquement installés dans votre bâtiment. Découvrez ce qu'il doit contenir et comment il se distingue du schéma unifilaire.","fr",{},"\u002Fblog\u002Fwhat-is-a-situation-plan.fr",{"title":755,"description":998},"plan-de-situation","blog\u002Fwhat-is-a-situation-plan.fr",[295,296,26,22,103,297,299,747,90,1006,1007,1008],"contrôle électrique","plan au sol","Belgique","C0nI_Vt_a9zOgViA9ATEI6ri8t5FF9JKFGPnVfaTAEc",{"id":1011,"title":1012,"articleId":6,"body":1013,"category":280,"date":281,"description":1256,"extension":283,"lastUpdated":284,"locale":1257,"meta":1258,"navigation":287,"path":1259,"publishDate":281,"readTime":289,"refreshInterval":290,"seo":1260,"slug":1261,"stem":1262,"tags":1263,"__hash__":1267},"blog\u002Fblog\u002Fwhat-is-a-situation-plan.nl.md","Wat is een situatieschema?",{"type":8,"value":1014,"toc":1247},[1015,1019,1032,1039,1043,1056,1095,1098,1102,1104,1137,1141,1221,1224,1228,1242],[11,1016,1018],{"id":1017},"een-plattegrond-van-uw-elektrische-installatie","Een plattegrond van uw elektrische installatie",[16,1020,1021,1022,1024,1025,1027,1028,1031],{},"Het situatieschema (Frans: ",[20,1023,26],{},", Duits: ",[20,1026,103],{},") is een vereenvoudigde plattegrond met de ",[29,1029,1030],{},"fysieke positie"," van het relevante elektrische materieel — bijvoorbeeld stopcontacten, schakelaars, lichtpunten, verdeelborden en vaste toestellen. Er geldt geen universele tekenschaal; leesbaarheid en eenduidige locaties zijn doorslaggevend.",[16,1033,1034,1035,1038],{},"In tegenstelling tot het eendraadschema toont het situatieschema niet de logische circuithiërarchie, maar ",[29,1036,1037],{},"waar precies"," alles zich bevindt.",[11,1040,1042],{"id":1041},"wat-zegt-het-arei","Wat zegt het AREI?",[16,1044,1045,1046,1050,1051,1055],{},"De ",[48,1047,1049],{"href":50,"rel":1048},[52],"officiële FOD-pagina over huishoudelijke controles"," noemt het eendraadschema en situatieschema als minimaal voor te leggen documenten. Het actuele ",[48,1052,1054],{"href":57,"rel":1053},[52],"AREI\u002FRGIE Boek 1"," beschrijft de inhoud en gezamenlijke verwijzingen:",[62,1057,1058,1070],{},[65,1059,1060],{},[68,1061,1062,1064,1067],{},[71,1063,543],{},[71,1065,1066],{},"AREI-artikel",[71,1068,1069],{},"Toont",[81,1071,1072,1083],{},[68,1073,1074,1078,1080],{},[86,1075,1076],{},[29,1077,298],{},[86,1079,93],{},[86,1081,1082],{},"Logische structuur — beschermingstoestellen, kringen, hiërarchie",[68,1084,1085,1090,1092],{},[86,1086,1087],{},[29,1088,1089],{},"Situatieschema",[86,1091,106],{},[86,1093,1094],{},"Fysieke positie — waar alles in het gebouw is geïnstalleerd, incl. locatie van de meterkast en aardingsinstallatie",[16,1096,1097],{},"De documenten moeten met de werkelijke installatie overeenstemmen. Ontbrekende of tegenstrijdige plannen kunnen als inbreuk in het verslag komen; alleen het erkende keuringsorganisme bepaalt de officiële conclusie.",[11,1099,1101],{"id":1100},"wat-moet-op-het-situatieschema-staan","Wat moet op het situatieschema staan?",[118,1103,586],{"id":585},[123,1105,1106,1109,1112,1115,1118,1121,1124,1127,1134],{},[126,1107,1108],{},"Duidelijke, vereenvoudigde plattegrond van elke betrokken verdieping",[126,1110,1111],{},"Positie van alle stopcontacten (enkel, dubbel, geaard)",[126,1113,1114],{},"Positie van alle schakelaars (aan\u002Fuit, wissel, dimmer)",[126,1116,1117],{},"Verlichtingspunten (plafond, wand, buiten)",[126,1119,1120],{},"Verdeelbord en meterpositie",[126,1122,1123],{},"Vast aangesloten toestellen (kookplaat, boiler, laadpaal)",[126,1125,1126],{},"Eenduidige locaties van het materieel waarnaar het eendraadschema verwijst",[126,1128,1129,1130,1133],{},"Kringreferentienummers (de nummering moet tussen situatieschema en eendraadschema ",[29,1131,1132],{},"identiek"," zijn)",[126,1135,1136],{},"Passende symbolen uit AREI\u002FRGIE-tabel 2.23 (hoofdstuk 2.13)",[11,1138,1140],{"id":1139},"situatieschema-vs-eendraadschema","Situatieschema vs. eendraadschema",[62,1142,1143,1154],{},[65,1144,1145],{},[68,1146,1147,1150,1152],{},[71,1148,1149],{},"Eigenschap",[71,1151,1089],{},[71,1153,298],{},[81,1155,1156,1167,1178,1188,1199,1210],{},[68,1157,1158,1161,1164],{},[86,1159,1160],{},"Weergave",[86,1162,1163],{},"Fysieke plattegrond",[86,1165,1166],{},"Logisch schakelschema",[68,1168,1169,1172,1175],{},[86,1170,1171],{},"Toont positie?",[86,1173,1174],{},"Ja — exacte locatie",[86,1176,1177],{},"Nee",[68,1179,1180,1183,1185],{},[86,1181,1182],{},"Toont hiërarchie?",[86,1184,1177],{},[86,1186,1187],{},"Ja — van net tot verbruiker",[68,1189,1190,1193,1196],{},[86,1191,1192],{},"Beschermingstoestellen",[86,1194,1195],{},"Alleen positie",[86,1197,1198],{},"Waarden, type, coördinatie",[68,1200,1201,1204,1207],{},[86,1202,1203],{},"Kabelinfo",[86,1205,1206],{},"Routes zichtbaar",[86,1208,1209],{},"Type en doorsnede vermeld",[68,1211,1212,1215,1218],{},[86,1213,1214],{},"Op schaal",[86,1216,1217],{},"Geen universele schaal; duidelijk en eenduidig",[86,1219,1220],{},"Niet op schaal",[16,1222,1223],{},"Beide documenten vullen elkaar aan en zijn beide verplicht.",[11,1225,1227],{"id":1226},"gerelateerde-artikelen","Gerelateerde artikelen",[123,1229,1230,1236],{},[126,1231,1232],{},[48,1233,1235],{"href":1234},"\u002Fblog\u002Feendraadschema-maken","Eendraadschema zelf maken — stap voor stap",[126,1237,1238],{},[48,1239,1241],{"href":1240},"\u002Fblog\u002Fkosten-elektriciteitsplan","Wat kost een elektroplan in België?",[16,1243,1244],{},[48,1245,1246],{"href":266},"Maak nu uw situatieschema met PlanElec — gratis →",{"title":269,"searchDepth":270,"depth":270,"links":1248},[1249,1250,1251,1254,1255],{"id":1017,"depth":270,"text":1018},{"id":1041,"depth":270,"text":1042},{"id":1100,"depth":270,"text":1101,"children":1252},[1253],{"id":585,"depth":277,"text":586},{"id":1139,"depth":270,"text":1140},{"id":1226,"depth":270,"text":1227},"Het situatieschema toont waar alle elektrische componenten fysiek in uw gebouw zijn geïnstalleerd. Ontdek wat erop moet staan en hoe het verschilt van een eendraadschema.","nl",{},"\u002Fblog\u002Fwhat-is-a-situation-plan.nl",{"title":1012,"description":1256},"wat-is-een-situatieschema","blog\u002Fwhat-is-a-situation-plan.nl",[295,296,22,1264,26,103,297,747,90,299,749,1265,1266],"situatieplan","plattegrond","België","r54HTwjraF1ziwZwDOVYpCsF3_vt6HiqucwSFQ_KwsE",1788389253175]