[{"data":1,"prerenderedAt":6229},["ShallowReactive",2],{"blog-post-de-verlegearten-arei-eindrahtschema":3,"blog-alternates-installation-methods-arei":1381},{"id":4,"title":5,"articleId":6,"body":7,"category":1358,"date":1359,"description":1360,"extension":1361,"lastUpdated":1359,"locale":1362,"meta":1363,"navigation":1364,"path":1365,"publishDate":1359,"readTime":1366,"refreshInterval":1367,"seo":1368,"slug":1369,"stem":1370,"tags":1371,"__hash__":1380},"blog\u002Fblog\u002Finstallation-methods-arei.de.md","Verlegearten nach AREI: welche Angabe gehört ins Eindrahtschema?","installation-methods-arei",{"type":8,"value":9,"toc":1341},"minimark",[10,15,45,52,395,402,406,419,440,444,449,513,519,539,543,546,568,582,602,606,609,687,694,702,706,716,719,723,733,743,753,775,795,813,817,827,830,837,841,844,943,972,976,979,1153,1160,1163,1167,1170,1220,1224,1301,1305,1330,1336],[11,12,14],"h2",{"id":13},"welche-verlegearten-kennt-das-arei-und-welche-gehört-ins-eindrahtschema","Welche Verlegearten kennt das AREI — und welche gehört ins Eindrahtschema?",[16,17,18,19,23,24,27,28,31,32,35,36,40,41,44],"p",{},"Das AREI zählt die zulässigen Verlegearten für Niederspannungsleitungen abschließend auf: siebzehn Buchstaben von ",[20,21,22],"em",{},"a"," bis ",[20,25,26],{},"q"," in ",[20,29,30],{},"Unterabschnitt 5.2.2.1",", von der Freileitung über Erdverlegung, Aufputz, Unterputz, Fußleisten und Kabelrinnen bis zu Heizleitungen in Decken und Böden. Für die meisten dieser Arten enthält ",[20,33,34],{},"Abschnitt 5.2.9"," zusätzlich eigene, verbindliche Regeln. Und die gewählte Art ist kein internes Detail des Installateurs: Das Einstrich-Schema einer hauswirtschaftlichen Anlage muss neben Typ, Querschnitt und Leiterzahl ausdrücklich die ",[37,38,39],"strong",{},"Arten der Verlegung elektrischer Leitungen"," angeben (",[20,42,43],{},"Unterabschnitt 3.1.2.2 Buchstabe a",").",[16,46,47,48,51],{},"Der Grund dafür steht an anderer Stelle im Regelwerk: Die Strombelastbarkeit IZ einer Leitung hängt unter anderem von der „Verlegeart und Umgebung der elektrischen Leitung“ ab (",[20,49,50],{},"Unterabschnitt 4.4.1.4","). Ohne die Verlegeart lässt sich also nicht beurteilen, ob ein Querschnitt zum Stromkreis passt — deshalb steht sie im Schema.",[53,54,55,78],"table",{},[56,57,58],"thead",{},[59,60,61,69,72,75],"tr",{},[62,63,64,65,68],"th",{},"Buchstabe (",[20,66,67],{},"5.2.2.1",")",[62,70,71],{},"Verlegeart",[62,73,74],{},"Typische Anwendung im Wohnbau",[62,76,77],{},"Besondere Regeln",[79,80,81,101,118,133,148,164,181,197,214,230,247,263,279,299,316,333,349,365,380],"tbody",{},[59,82,83,86,89,92],{},[84,85,22],"td",{},[84,87,88],{},"Freileitungen",[84,90,91],{},"Zuleitung zum Nebengebäude",[84,93,94,97,98,68],{},[20,95,96],{},"5.2.9.1"," (verweist auf Buch 3, ",[20,99,100],{},"Kapitel 7.1",[59,102,103,106,109,112],{},[84,104,105],{},"b.1",[84,107,108],{},"direkt erdverlegt",[84,110,111],{},"Gartensteckdose, Carport",[84,113,114,117],{},[20,115,116],{},"5.2.9.2 Buchstabe a",": ≥ 0,60 m Tiefe, nur Kabel",[59,119,120,123,126,129],{},[84,121,122],{},"b.2",[84,124,125],{},"erdverlegt mit mechanischem Schutz",[84,127,128],{},"Kabel unter Abdeckband",[84,130,131],{},[20,132,116],{},[59,134,135,138,141,144],{},[84,136,137],{},"b.3",[84,139,140],{},"erdverlegt in Kabelrohren",[84,142,143],{},"Durchführung unter Einfahrt oder Terrasse",[84,145,146],{},[20,147,116],{},[59,149,150,153,156,159],{},[84,151,152],{},"c",[84,154,155],{},"Fahrleitungen für Wälz- oder Gleitkontakte",[84,157,158],{},"im Wohnbau nicht relevant",[84,160,161],{},[20,162,163],{},"5.2.1.4 Buchstabe a",[59,165,166,169,172,175],{},[84,167,168],{},"d",[84,170,171],{},"auf Putz",[84,173,174],{},"XVB sichtbar im Keller, Technikraum, Garage",[84,176,177,180],{},[20,178,179],{},"5.2.9.5",": nur Kabel; Wandabstand ≤ 0,3 × Außendurchmesser",[59,182,183,186,189,192],{},[84,184,185],{},"e",[84,187,188],{},"unter Putz (in eingelassenen Rohren)",[84,190,191],{},"Standard im Neubau: VOB im Preflex",[84,193,194],{},[20,195,196],{},"5.2.9.3",[59,198,199,202,205,208],{},[84,200,201],{},"f",[84,203,204],{},"in Leisten, Fußleisten und Einfassungen",[84,206,207],{},"Renovierung, sichtbarer Kabelkanal",[84,209,210,213],{},[20,211,212],{},"5.2.9.4",": nur isolierte Leiter oder Einleiterkabel",[59,215,216,219,222,225],{},[84,217,218],{},"g",[84,220,221],{},"im Freien mit Schellen, auf Kabelwannen, -leitern, -pritschen, Auslegern",[84,223,224],{},"Technikraum, Heizungsraum",[84,226,227,229],{},[20,228,179],{},": Wandabstand ≥ 0,3 × Außendurchmesser",[59,231,232,235,238,241],{},[84,233,234],{},"h",[84,236,237],{},"in Kabelschächten und Kabelrinnen",[84,239,240],{},"Verteilertrasse im Technikraum",[84,242,243,246],{},[20,244,245],{},"5.2.9.6",": in Rinnen nur Kabel; isolierte Leiter nur in Kabelschächten",[59,248,249,252,255,258],{},[84,250,251],{},"i",[84,253,254],{},"in einem Kabelschutz",[84,256,257],{},"Trasse über dem Boden",[84,259,260],{},[20,261,262],{},"5.2.9.7",[59,264,265,268,271,274],{},[84,266,267],{},"j",[84,269,270],{},"in offenen, geschlossenen oder sandgefüllten Kabelkanälen",[84,272,273],{},"Bodenkanal, Industrieanlage",[84,275,276],{},[20,277,278],{},"5.2.9.8",[59,280,281,284,287,290],{},[84,282,283],{},"k",[84,285,286],{},"in baulichen Hohlräumen, Aussparungen, vorgefertigten Blöcken",[84,288,289],{},"Hohlblockstein, Zwischendecke",[84,291,292,295,296],{},[20,293,294],{},"5.2.9.9"," und ",[20,297,298],{},"4.3.3.5 Buchstabe b",[59,300,301,304,307,310],{},[84,302,303],{},"l",[84,305,306],{},"hinter Wandplatten",[84,308,309],{},"Trockenbau, Ständerwand",[84,311,312,295,314],{},[20,313,294],{},[20,315,298],{},[59,317,318,321,324,327],{},[84,319,320],{},"m",[84,322,323],{},"direkte Unterputzverlegung, ohne Rohre",[84,325,326],{},"XVB direkt im Schlitz",[84,328,329,332],{},[20,330,331],{},"5.2.9.10",": Installationszonen, Beton ≥ 3 cm, Putz ≥ 0,4 cm",[59,334,335,338,341,344],{},[84,336,337],{},"n",[84,339,340],{},"in Schienenverteilern",[84,342,343],{},"im Wohnbau selten",[84,345,346],{},[20,347,348],{},"5.2.9.11",[59,350,351,354,357,360],{},[84,352,353],{},"o",[84,355,356],{},"auf Isolatoren",[84,358,359],{},"Altbestand",[84,361,362],{},[20,363,364],{},"5.2.9.12",[59,366,367,369,372,375],{},[84,368,16],{},[84,370,371],{},"unter Wasser",[84,373,374],{},"Schwimmbadtechnik",[84,376,377],{},[20,378,379],{},"5.2.2.1 Buchstabe p",[59,381,382,384,387,390],{},[84,383,26],{},[84,385,386],{},"in Decken, Fußböden und Wänden für Heizleitungen und -flächen",[84,388,389],{},"Fußbodenheizung, Heizmatten",[84,391,392],{},[20,393,394],{},"5.2.9.13",[16,396,397,398,401],{},"Andere Verlegearten sind nicht verboten, aber sie fallen unter die Auffangregel: Sie entsprechen „den diesbezüglichen Regeln des Fachs“ (",[20,399,400],{},"Unterabschnitt 5.2.2.4","). Wer außerhalb der Liste arbeitet, verlässt damit den Bereich, für den das AREI selbst eine Regel formuliert.",[11,403,405],{"id":404},"was-unterscheidet-buchstabe-e-von-buchstabe-m","Was unterscheidet Buchstabe e von Buchstabe m?",[16,407,408,409,411,412,414,415,418],{},"Diese beiden sind der häufigste Verwechslungspunkt, weil beide im Deutschen „unter Putz“ heißen. Der Unterschied ist das Rohr. Die niederländische Fassung nennt Buchstabe ",[20,410,185],{}," „in verzonken buizen“, die französische „sous conduits encastrés“ — also Leitungen in eingelassenen Elektroinstallationsrohren. Buchstabe ",[20,413,320],{}," heißt dagegen ausdrücklich „direkte Unterputzverlegung, ",[37,416,417],{},"ohne"," Elektroinstallationsrohre“.",[16,420,421,422,424,425,428,429,424,431,434,435,439],{},"Das ist keine Wortklauberei, sondern der Unterschied zwischen zwei Regelwerken: Für ",[20,423,185],{}," gilt ",[20,426,427],{},"Unterabschnitt 5.2.9.3"," mit den Rohrregeln (Krümmungsradien, jederzeit einziehbare Leiter, keine Verbindungen im Rohr). Für ",[20,430,320],{},[20,432,433],{},"Unterabschnitt 5.2.9.10"," mit den Installationszonen und den Mindestdeckungen. Welches Material man in welchem Fall wählt und was das kostet, ist in ",[22,436,438],{"href":437},"\u002Fde\u002Fblog\u002Fpreflex-vs-freie-verlegung","Preflex vs. freie Verlegung"," verglichen; dieser Artikel beschreibt die Systematik, in der beide Varianten stehen.",[11,441,443],{"id":442},"warum-bestimmt-die-verlegeart-die-zulässige-strombelastbarkeit","Warum bestimmt die Verlegeart die zulässige Strombelastbarkeit?",[16,445,446,448],{},[20,447,50],{}," nennt fünf Größen, von denen IZ abhängt. Die Verlegeart ist eine davon, und sie ist die einzige, die man einem Kabel nicht ansieht.",[53,450,451,464],{},[56,452,453],{},[59,454,455,461],{},[62,456,457,458],{},"Einflussgröße nach ",[20,459,460],{},"4.4.1.4",[62,462,463],{},"Was sie im Plan bedeutet",[79,465,466,477,485,493,502],{},[59,467,468,471],{},[84,469,470],{},"Leiterquerschnitt",[84,472,473,474,68],{},"Angabe im Eindrahtschema (",[20,475,476],{},"3.1.2.2 Buchstabe a",[59,478,479,482],{},[84,480,481],{},"Isolierung der Leiter",[84,483,484],{},"Kabeltyp, z. B. XVB oder VOB",[59,486,487,490],{},[84,488,489],{},"Beschaffenheit der elektrischen Leitung",[84,491,492],{},"Ein- oder Mehrleiterkabel, Bewehrung, Schirm",[59,494,495,498],{},[84,496,497],{},"Verlegeart und Umgebung",[84,499,473,500,68],{},[20,501,476],{},[59,503,504,507],{},[84,505,506],{},"Umgebungstemperatur",[84,508,509,510],{},"Ort der Leitung, siehe ",[20,511,512],{},"5.2.3.1",[16,514,515,516,518],{},"Der eigentliche Rechenweg steht nicht im AREI. Der Text sagt nur: Die Strombelastbarkeit „wird gemäß den Regeln des Fachs berechnet“ (",[20,517,460],{},"), und die zuständigen Minister können dafür nähere Regeln erlassen. In der Praxis heißt das: Die Tabellen und Korrekturfaktoren kommen aus den einschlägigen Normen der Reihe NBN HD 60364-5-52, nicht aus dem AREI.",[16,520,521,522,525,526,529,530,533,534,538],{},"Was das AREI selbst festlegt, ist etwas anderes und wird oft damit verwechselt: ",[20,523,524],{},"Tabelle 4.11"," nennt für hauswirtschaftliche Anlagen die ",[37,527,528],{},"maximale"," Nennstromstärke je Leiterquerschnitt, getrennt für Sicherung und Leitungsschutzschalter: bei 1,5 mm² 10 A beziehungsweise 16 A, bei 2,5 mm² 16 A beziehungsweise 20 A, bei 4 mm² 20 A beziehungsweise 25 A, bei 6 mm² 32 A beziehungsweise 40 A, bei 10 mm² 50 A beziehungsweise 63 A. Diese Tabelle kennt die Verlegeart nicht. Sie ist eine Obergrenze, keine Freigabe: Die Bedingung IZ ≥ IB aus ",[20,531,532],{},"Unterabschnitt 5.2.1.2 Buchstabe a"," muss zusätzlich erfüllt sein. Die Zuordnung Querschnitt zu Absicherung ist in ",[22,535,537],{"href":536},"\u002Fde\u002Fblog\u002Fkabelquerschnitt-sicherungsautomat","Kabelquerschnitt und Sicherungsautomat"," ausführlich behandelt.",[11,540,542],{"id":541},"was-machen-häufung-umgebungstemperatur-und-wärmedämmung-mit-der-belastbarkeit","Was machen Häufung, Umgebungstemperatur und Wärmedämmung mit der Belastbarkeit?",[16,544,545],{},"Alle drei senken IZ, und in allen drei Fällen liefert das AREI die Randbedingung, nicht den Faktor.",[16,547,548,551,552,555,556,559,560,563,564,567],{},[37,549,550],{},"Häufung."," Das AREI definiert die Grenze exakt: Ein Kabel oder isolierter Leiter gilt als ",[37,553,554],{},"einzeln verlegt",", wenn er mindestens 20 mm Abstand zu jedem anderen Kabel oder isolierten Leiter hat (",[20,557,558],{},"Abschnitt 2.7.1","). Alles darunter ist „in Bündeln oder in ebener Anordnung“ verlegt. Diese Unterscheidung hat im AREI eine unmittelbare Folge — allerdings für den Brandschutz, nicht für die Erwärmung: Einzeln verlegte Leiter und Kabel brauchen mindestens die Eigenschaft F1 beziehungsweise die CPR-Klasse Eca (",[20,561,562],{},"Unterabschnitt 5.2.7.2","), in Bündeln oder in ebener Anordnung mindestens F2 beziehungsweise Cca (",[20,565,566],{},"Unterabschnitt 5.2.7.3","), und zwar „unabhängig von der Länge der Strecke“, über die tatsächlich gebündelt wird. Der thermische Häufungsfaktor selbst folgt wieder aus den Regeln des Fachs.",[16,569,570,573,574,577,578,581],{},[37,571,572],{},"Umgebungstemperatur."," ",[20,575,576],{},"Unterabschnitt 5.2.3.1"," verlangt, dass Leitungen für die niedrigste und höchste örtliche Umgebungstemperatur geeignet sind und nur innerhalb des vom Hersteller angegebenen Temperaturbereichs verlegt werden. Dazu kommt ",[20,579,580],{},"Abschnitt 5.2.8",": Leitungen dürfen in der Nähe von Heizungs- oder Warmluftleitungen und Rauchabzügen keinen schädlichen Temperaturen ausgesetzt sein und müssen ausreichend Abstand halten oder durch eine Wärmeabschirmung getrennt sein. Wer eine Leitung parallel neben die Heizungsverteilung legt, ändert damit ihre thermische Umgebung — und die ist Teil derselben Angabe wie die Verlegeart.",[16,583,584,587,588,591,592,594,595,598,599,601],{},[37,585,586],{},"Wärmedämmung."," Hier ist die Lage ehrlich zu benennen: Das AREI enthält für Leitungen in oder unter Wärmedämmung ",[37,589,590],{},"keinen"," eigenen Reduktionsfaktor. „Wärmedämmung“ taucht im Regelwerk als Vorkehrung bei Temperaturen unter −25 °C auf (",[20,593,512],{},") und im Kapitel über Heizflächen, wo Dämmmaterial in Berührung mit der Heizungsanlage nicht brennbar sein muss (",[20,596,597],{},"5.2.9.13 Buchstabe b.5","). Eine Leitung, die in einer gedämmten Dachschräge oder unter Aufdachdämmung liegt, fällt damit unter „Verlegeart und Umgebung“ nach ",[20,600,460],{}," und ist nach den Regeln des Fachs zu bewerten — nicht nach einer AREI-Tabelle, die es nicht gibt.",[11,603,605],{"id":604},"wo-gehört-die-verlegeart-hin-eindrahtschema-situationsplan-oder-materialliste","Wo gehört die Verlegeart hin — Eindrahtschema, Situationsplan oder Materialliste?",[16,607,608],{},"Diese drei Dokumente haben im AREI klar getrennte Pflichtinhalte.",[53,610,611,624],{},[56,612,613],{},[59,614,615,618,621],{},[62,616,617],{},"Unterlage",[62,619,620],{},"Verlegeart verlangt?",[62,622,623],{},"Fundstelle",[79,625,626,641,658,673],{},[59,627,628,631,637],{},[84,629,630],{},"Einstrich-Schema (hauswirtschaftlich)",[84,632,633,636],{},[37,634,635],{},"ja",", ausdrücklich",[84,638,639],{},[20,640,476],{},[59,642,643,646,653],{},[84,644,645],{},"Lageplan (hauswirtschaftlich)",[84,647,648,649,652],{},"nein — dort steht die ",[37,650,651],{},"Lage"," der Bestandteile",[84,654,655],{},[20,656,657],{},"3.1.2.3 Buchstabe a",[59,659,660,663,668],{},[84,661,662],{},"Schaltplan (nicht hauswirtschaftlich)",[84,664,665,667],{},[37,666,635],{},", zusammen mit Länge und Leiterzahl",[84,669,670],{},[20,671,672],{},"3.1.2.2 Buchstabe b",[59,674,675,678,681],{},[84,676,677],{},"Materialliste",[84,679,680],{},"nicht vorgeschrieben",[84,682,683,684],{},"zulässig als Anlage nach ",[20,685,686],{},"3.1.2.1 Buchstabe c",[16,688,689,690,693],{},"Die Materialliste ist im AREI keine Pflichtunterlage. ",[20,691,692],{},"Unterabschnitt 3.1.2.1 Buchstabe c"," erlaubt lediglich, Schemata und Pläne durch Unterlagen zu ergänzen, „in denen die verschiedenen Eigenschaften der elektrischen Betriebsmittel und\u002Foder Produkte näher beschrieben werden“. Eine Kabelliste mit Verlegeart je Leitung ist genau so eine Anlage: nützlich für Kalkulation und Ausführung, aber sie entbindet nicht davon, die Angabe im Einstrich-Schema selbst zu führen.",[16,695,696,697,701],{},"Wie sich Schema und Lageplan sonst aufteilen, ist in ",[22,698,700],{"href":699},"\u002Fde\u002Fblog\u002Fkabelwege-und-leitungslaengen-ermitteln","Kabelwege und Leitungslängen"," beschrieben; dort steht auch, warum die Länge nur im nicht hauswirtschaftlichen Schaltplan Pflichtangabe ist.",[11,703,705],{"id":704},"wann-ändert-sich-die-verlegeart-innerhalb-einer-leitung","Wann ändert sich die Verlegeart innerhalb einer Leitung?",[16,707,708,709,712,713,44],{},"Eine Leitung hat selten nur eine Verlegeart. Vom Verteiler durch die Wand, über die Decke, ins Erdreich und wieder an eine Außenwand — das sind vier. Das AREI hat für diesen Fall einen eigenen Begriff: Als ",[37,710,711],{},"Beginn des Stromkreises"," gilt entweder der Beginn der elektrischen Leitung „oder der Ort, an dem sich Querschnitt, Art oder Beschaffenheit der elektrischen Leitung oder ihre Verlegeart ändert“ (",[20,714,715],{},"Abschnitt 2.6.1",[16,717,718],{},"Praktisch heißt das: Jeder Wechsel der Verlegeart ist eine eigene Betrachtungsstrecke. Für die Bemessung zählt die ungünstigste — eine Leitung, die auf zwei Metern durch ein Rohrbündel läuft und danach frei in der Decke liegt, wird nicht nach der freien Strecke bemessen. Für die Angabe im Schema heißt es: Alle vorkommenden Arten gehören dokumentiert, nicht nur die längste.",[11,720,722],{"id":721},"welche-regeln-gelten-für-unter-putz-verlegte-leitungen","Welche Regeln gelten für unter Putz verlegte Leitungen?",[16,724,725,726,729,730,732],{},"Für die direkte Verlegung ohne Rohr (",[20,727,728],{},"Buchstabe m",") ist ",[20,731,433],{}," die maßgebliche Stelle, und sie ist ungewöhnlich konkret.",[16,734,735,736,739,740,44],{},"In ",[37,737,738],{},"Beton oder Zement"," eingebaute Leitungen werden mit einer mindestens 3 cm dicken Beton- oder Zementschicht überdeckt; Leiter mit nur Basisisolierung dürfen dort gar nicht eingebaut werden (",[20,741,742],{},"Buchstabe a",[16,744,735,745,748,749,752],{},[37,746,747],{},"Wände von Räumlichkeiten"," eingebaute Leitungen ohne Rohr müssen zusätzlich in den Installationszonen bleiben (",[20,750,751],{},"Buchstabe b","):",[754,755,756,760,763,766,769,772],"ul",{},[757,758,759],"li",{},"Der Verlauf ist ausschließlich waagerecht oder senkrecht; waagerechte Führungen in Decken verlaufen rechtwinklig zu den senkrechten Wänden.",[757,761,762],{},"Waagerechte Führungen liegen 25 bis 35 cm über dem Boden beziehungsweise unter der Decke, ebenso 25 bis 35 cm über der Unterseite von Fensterstürzen — sofern dann mindestens 25 cm Abstand zur Decke bleibt.",[757,764,765],{},"Senkrechte Führungen liegen so nah wie möglich an einer Raumecke oder 10 bis 20 cm von Türeinfassungen und -zargen entfernt.",[757,767,768],{},"Außerhalb dieser Zonen ist nur die senkrechte Führung über einem sichtbaren Gerät zulässig.",[757,770,771],{},"Die Leitungen werden weder bei der Verlegung noch danach mechanisch beansprucht und ohne Beschädigung befestigt.",[757,773,774],{},"Die abdeckende Putzschicht ist mindestens 0,4 cm dick.",[16,776,777,778,780,781,784,785,788,789,792,793,44],{},"Für Rohre gilt statt dessen ",[20,779,427],{},": Leiter oder Kabel müssen jederzeit einziehbar und entfernbar bleiben (",[20,782,783],{},"Buchstabe e","), Verbindungen im Rohr sind verboten (",[20,786,787],{},"Buchstabe f","), und in eingebauten Rohren sind T-Stücke und Winkel unzulässig, während Leiter in Verbindungs-, Abzweig- und Zugdosen zugänglich bleiben (",[20,790,791],{},"Buchstabe i.2","). Rohre aus brennbarem Material dürfen nur verwendet werden, wenn sie mindestens 3 cm tief in nicht brennbare Materialien eingebaut sind (",[20,794,787],{},[16,796,797,798,801,802,805,806,809,810,812],{},"Eine wichtige Ausnahme: Für ",[37,799,800],{},"Kleinspannungsanlagen"," gilt der Zonenkatalog aus ",[20,803,804],{},"5.2.9.10 Buchstabe b"," ausdrücklich nicht (",[20,807,808],{},"Unterabschnitt 5.2.9.15 Buchstabe b","). Bus-, Klingel- und Steuerleitungen auf ELV müssen sich also nicht an das Zonenraster halten — die übrigen Regeln von ",[20,811,34],{}," bleiben anwendbar.",[11,814,816],{"id":815},"was-gilt-für-erdverlegte-leitungen","Was gilt für erdverlegte Leitungen?",[16,818,819,822,823,826],{},[20,820,821],{},"Unterabschnitt 5.2.9.2 Buchstabe a"," ist eine der klarsten Stellen im ganzen Kapitel. In der Erde und in unzugänglichen unterirdischen Kabelrohren dürfen — mit Ausnahme unabhängiger Schutzleiter — ",[37,824,825],{},"nur Kabel"," verlegt werden. Die Mindesttiefe beträgt 0,60 m, gemessen von der Bodenoberfläche, „sofern dies aus technischen Gründen nicht unmöglich ist“. Ist die Tiefe nicht erreichbar, tritt an ihre Stelle ein durchgehendes oder abgedichtetes Kabelrohr aus dauerhaftem, widerstandsfähigem Material.",[16,828,829],{},"Zusätzlich muss das Kabel eine von drei Bedingungen erfüllen: geerdeter Schutzschirm mit Bewehrung oder verstärktem Außenmantel; oder ein widerstandsfähiger Außenmantel plus eine durchgehende Abdeckung, die bei Ausschachtungsarbeiten schützt und beidseitig übersteht; oder Verlegung in einem Kabelrohr beziehungsweise gleichwertigen System. Ist eine dieser Bedingungen erfüllt, sind für den Schutz gegen elektrischen Schlag keine zusätzlichen Maßnahmen erforderlich.",[16,831,832,833,836],{},"Für die Kennzeichnung im Erdreich enthält ",[20,834,835],{},"Buchstabe d"," eigene Regeln — Markierungen an den Enden gerader Abschnitte, mindestens alle 200 m, mit einer Mindestfläche von 0,01 m² und einem Blitz im Relief. Anschlüsse von Niederspannungsnetzbenutzern sind davon ausgenommen.",[11,838,840],{"id":839},"welches-kabel-darf-in-welche-verlegeart","Welches Kabel darf in welche Verlegeart?",[16,842,843],{},"Die Verlegeart schränkt die Kabelwahl ein, und zwar unabhängig vom Querschnitt.",[53,845,846,857],{},[56,847,848],{},[59,849,850,852,855],{},[62,851,71],{},[62,853,854],{},"Zulässig",[62,856,623],{},[79,858,859,871,882,893,905,918,931],{},[59,860,861,864,866],{},[84,862,863],{},"erdverlegt",[84,865,825],{},[84,867,868],{},[20,869,870],{},"5.2.9.2 a",[59,872,873,876,878],{},[84,874,875],{},"im Freien oder auf Putz",[84,877,825],{},[84,879,880],{},[20,881,179],{},[59,883,884,887,889],{},[84,885,886],{},"Kabelrinne",[84,888,825],{},[84,890,891],{},[20,892,245],{},[59,894,895,898,901],{},[84,896,897],{},"Kabelschacht",[84,899,900],{},"auch isolierte Leiter, außerhalb elektrischer Betriebsstätten mit vollwandigem Schacht und werkzeugbedientem Deckel",[84,902,903],{},[20,904,245],{},[59,906,907,910,913],{},[84,908,909],{},"Leisten, Fußleisten, Einfassungen",[84,911,912],{},"isolierte Leiter oder Einleiterkabel",[84,914,915],{},[20,916,917],{},"5.2.9.4 b",[59,919,920,923,926],{},[84,921,922],{},"Elektroinstallationsrohr",[84,924,925],{},"isolierte Leiter oder Kabel",[84,927,928],{},[20,929,930],{},"5.2.9.3 b",[59,932,933,936,939],{},[84,934,935],{},"bauliche Hohlräume",[84,937,938],{},"keine Leiter mit nur Basisisolierung",[84,940,941],{},[20,942,294],{},[16,944,945,946,949,950,953,954,957,958,961,962,966,967,971],{},"Dazu kommt die Brandklasse. In ",[37,947,948],{},"baulichen Hohlräumen"," sowie in ",[37,951,952],{},"Leisten, Fußleisten oder Einfassungen aus brennbaren Materialien"," verlangt ",[20,955,956],{},"Unterabschnitt 4.3.3.5 Buchstabe b"," ausdrücklich die Eigenschaft beziehungsweise Klasse aus ",[20,959,960],{},"5.2.7.3"," — also F2 oder mindestens Cca. Eine Holzständerwand ist ein baulicher Hohlraum. Welcher Kabeltyp zu welchem Einsatz passt, ist in ",[22,963,965],{"href":964},"\u002Fde\u002Fblog\u002Fxvb-vs-vob-kabel","XVB oder VOB"," beschrieben; für Bad- und Feuchtbereiche gelten zusätzlich die Bereichsregeln aus ",[22,968,970],{"href":969},"\u002Fde\u002Fblog\u002Fbadezimmer-kabel-arei-zonen","Badezimmerkabel und AREI-Zonen",".",[11,973,975],{"id":974},"wie-hält-planelec-die-verlegeart-fest-und-was-steht-im-export","Wie hält PlanElec die Verlegeart fest, und was steht im Export?",[16,977,978],{},"PlanElec kennt zwölf für den Wohnbau praxisrelevante Verlegearten und hinterlegt zu jeder den AREI-Verweis, unter dem sie steht:",[53,980,981,994],{},[56,982,983],{},[59,984,985,988,991],{},[62,986,987],{},"Auswahl in PlanElec",[62,989,990],{},"Kurzcode",[62,992,993],{},"Hinterlegter AREI-Verweis",[79,995,996,1009,1025,1038,1051,1063,1075,1088,1101,1114,1127,1140],{},[59,997,998,1001,1004],{},[84,999,1000],{},"Aufputz",[84,1002,1003],{},"AP",[84,1005,1006],{},[20,1007,1008],{},"5.2.2.1 d",[59,1010,1011,1014,1017],{},[84,1012,1013],{},"Elektroinstallationsrohr auf Putz",[84,1015,1016],{},"AR",[84,1018,1019,1021,1022],{},[20,1020,1008],{}," \u002F ",[20,1023,1024],{},"5.2.9.3 h",[59,1026,1027,1030,1033],{},[84,1028,1029],{},"Unterputz im Leerrohr",[84,1031,1032],{},"UR",[84,1034,1035],{},[20,1036,1037],{},"5.2.2.1 e",[59,1039,1040,1043,1046],{},[84,1041,1042],{},"Unterputz direkt",[84,1044,1045],{},"UD",[84,1047,1048],{},[20,1049,1050],{},"5.2.2.1 m",[59,1052,1053,1056,1059],{},[84,1054,1055],{},"Im Elektroinstallationsrohr",[84,1057,1058],{},"IR",[84,1060,1061],{},[20,1062,196],{},[59,1064,1065,1068,1071],{},[84,1066,1067],{},"Bündel von Elektroinstallationsrohren",[84,1069,1070],{},"RB",[84,1072,1073],{},[20,1074,196],{},[59,1076,1077,1080,1083],{},[84,1078,1079],{},"Hohlwand \u002F Wandplatten",[84,1081,1082],{},"HW",[84,1084,1085],{},[20,1086,1087],{},"5.2.2.1 k + l",[59,1089,1090,1093,1096],{},[84,1091,1092],{},"Fußleiste \u002F Kabelkanal",[84,1094,1095],{},"FL",[84,1097,1098],{},[20,1099,1100],{},"5.2.2.1 f",[59,1102,1103,1106,1109],{},[84,1104,1105],{},"Erdverlegt",[84,1107,1108],{},"EV",[84,1110,1111],{},[20,1112,1113],{},"5.2.2.1 b.1 + b.2",[59,1115,1116,1119,1122],{},[84,1117,1118],{},"Erdverlegt im Kabelrohr",[84,1120,1121],{},"ER",[84,1123,1124],{},[20,1125,1126],{},"5.2.2.1 b.3",[59,1128,1129,1132,1135],{},[84,1130,1131],{},"Kabelwanne \u002F -rinne",[84,1133,1134],{},"KW",[84,1136,1137],{},[20,1138,1139],{},"5.2.2.1 g + h",[59,1141,1142,1145,1148],{},[84,1143,1144],{},"Frei in Decke\u002FHohlraum",[84,1146,1147],{},"FV",[84,1149,1150],{},[20,1151,1152],{},"5.2.2.1 g",[16,1154,1155,1156,1159],{},"Die Verlegeart hängt an der Teilstrecke, nicht am ganzen Kabel: Ein Kabelweg im Grundriss kann abschnittsweise verschiedene Arten tragen, und jede Teilstrecke wird in ihrer eigenen Farbe mit dem zweibuchstabigen Kurzcode dargestellt. Im Eindrahtschema wird standardmäßig ",[37,1157,1158],{},"eine"," maßgebliche Art gezeichnet — die restriktivste der vorkommenden. Arten, für die im Werkzeug keine belastbare Referenztabelle hinterlegt ist, erhalten dabei bewusst Vorrang, statt durch eine erfundene thermische Bewertung verdeckt zu werden.",[16,1161,1162],{},"Seit dem Update vom 28. August 2026 lassen sich Leitungen im Rohr, Rohrbündel, erdverlegte Leitungen im Kabelrohr und Rohre auf der Wand getrennt auswählen; jede Verlegeart trägt in Kabelmenü, Editor, Vorschau und PDF dasselbe vollständige Zeichen mit eigener Trägerlinie. Diese Trägerlinie ist der Grund, warum sich Aufputz und Unterputz überhaupt unterscheiden lassen: Sie stellt den Leiter dar, und ob die Mauerzeichen darüber oder darunter liegen, ist die eigentliche Aussage. Seit dem 29. August 2026 lässt sich die Verlegeart direkt im Schema anklicken; das Kabelmenü erscheint an der gewählten Stelle und bleibt zusätzlich im Eigenschaften-Panel erreichbar. In der Kabelliste erscheint sie als eigene Spalte „Verlegeart“.",[11,1164,1166],{"id":1165},"was-die-arei-selbstprüfung-zur-verlegeart-nicht-leistet","Was die AREI-Selbstprüfung zur Verlegeart nicht leistet",[16,1168,1169],{},"Die Selbstprüfung ist orientierend. Für die Verlegeart heißt das konkret:",[754,1171,1172,1182,1190,1200,1205],{},[757,1173,1174,1175,1178,1179,1181],{},"Sie prüft ",[37,1176,1177],{},"nicht"," die Strombelastbarkeit unter der erfassten Verlegeart. Geprüft wird, ob der Kabelquerschnitt zur Nennstromstärke der Absicherung passt — das ist die Zuordnung aus ",[20,1180,524],{},", und die kennt die Verlegeart nicht. Häufung, Umgebungstemperatur und Dämmung gehen in keine Prüfung ein.",[757,1183,1174,1184,1186,1187,1189],{},[37,1185,1177],{},", ob die Installationszonen aus ",[20,1188,804],{}," eingehalten sind, ob die Putz- oder Betondeckung ausreicht oder ob eine Erdleitung tief genug liegt. Das sind Maße am Bau, nicht Angaben im Modell.",[757,1191,1174,1192,1194,1195,1021,1197,1199],{},[37,1193,1158],{}," verlegeartabhängige Regel: In baulichen Hohlräumen verlegte Kabel müssen im Leerrohr geführt werden oder mindestens die CPR-Klasse Cca erreichen (",[20,1196,298],{},[20,1198,960],{},"). Fehlt die Brandklasse, meldet PlanElec eine Datenlücke statt eines Fehlers; liegt sie unter Cca und ist kein Rohr dokumentiert, ist es ein Fehler.",[757,1201,1174,1202,1204],{},[37,1203,1177],{},", ob die eingetragene Verlegeart der später tatsächlich ausgeführten entspricht. Das ist eine Sichtprüfung vor Ort.",[757,1206,1207,1208,1211,1212,1215,1216,971],{},"Sie ersetzt ",[37,1209,1210],{},"weder"," Messung ",[37,1213,1214],{},"noch"," Kontrolle; die offizielle Beurteilung erfolgt ausschließlich durch eine zugelassene Stelle. Der vollständige Prüfumfang steht in ",[22,1217,1219],{"href":1218},"\u002Fde\u002Fhelp\u002Fwas-die-selbstpruefung-kontrolliert","Was die Selbstprüfung kontrolliert",[11,1221,1223],{"id":1222},"welche-fehler-fallen-bei-der-kontrolle-auf","Welche Fehler fallen bei der Kontrolle auf?",[754,1225,1226,1238,1246,1255,1265,1274,1284,1292],{},[757,1227,1228,1231,1232,1234,1235,1237],{},[37,1229,1230],{},"Isolierte Leiter statt Kabel auf Putz oder in der Kabelrinne."," VOB-Adern sichtbar an der Wand oder lose in einer Rinne verstoßen gegen ",[20,1233,179],{}," beziehungsweise ",[20,1236,245],{}," — dort sind ausschließlich Kabel zugelassen.",[757,1239,1240,1243,1244,971],{},[37,1241,1242],{},"Schlitz außerhalb der Installationszonen."," Diagonale Führungen und Verläufe quer durch die Wandmitte sind der Klassiker zu ",[20,1245,804],{},[757,1247,1248,1251,1252,44],{},[37,1249,1250],{},"Zu dünne Deckung."," Weniger als 0,4 cm Putz über der Leitung oder weniger als 3 cm Beton bei eingegossenen Leitungen (",[20,1253,1254],{},"5.2.9.10 Buchstaben a und b",[757,1256,1257,1260,1261,1264],{},[37,1258,1259],{},"Verbindung im Rohr."," Klemmstellen und Lüsterklemmen im Elektroinstallationsrohr sind verboten (",[20,1262,1263],{},"5.2.9.3 Buchstabe f","); Anschlüsse in Zug- und Verbindungskästen gehören auf einen geeigneten Klemmenblock.",[757,1266,1267,1270,1271,44],{},[37,1268,1269],{},"Rohr nicht mehr nachziehbar."," Zu enge Krümmungen oder überfüllte Rohre verletzen die Forderung, dass Leiter jederzeit eingezogen und entfernt werden können (",[20,1272,1273],{},"5.2.9.3 Buchstabe e",[757,1275,1276,1279,1280,1021,1282,44],{},[37,1277,1278],{},"Hohlraum mit Eca statt Cca und ohne Rohr."," Ein häufiger Befund im Holzbau und in abgehängten Decken (",[20,1281,298],{},[20,1283,960],{},[757,1285,1286,1289,1290,44],{},[37,1287,1288],{},"Erdkabel zu flach."," Weniger als 0,60 m ohne durchgehendes Schutzrohr (",[20,1291,116],{},[757,1293,1294,1297,1298,1300],{},[37,1295,1296],{},"Verlegeart fehlt im Schema."," Ein Einstrich-Schema mit Typ, Querschnitt und Leiterzahl, aber ohne Verlegeart, ist unvollständig (",[20,1299,476],{},") — unabhängig davon, wie sauber die Anlage ausgeführt ist.",[11,1302,1304],{"id":1303},"weiterführende-artikel","Weiterführende Artikel",[754,1306,1307,1311,1315,1320,1324],{},[757,1308,1309],{},[22,1310,537],{"href":536},[757,1312,1313],{},[22,1314,700],{"href":699},[757,1316,1317],{},[22,1318,1319],{"href":964},"XVB oder VOB: welches Kabel wofür",[757,1321,1322],{},[22,1323,438],{"href":437},[757,1325,1326],{},[22,1327,1329],{"href":1328},"\u002Fde\u002Fblog\u002Feindrahtschema-erstellen","Eindrahtschema erstellen: Schritt für Schritt",[16,1331,1332],{},[22,1333,1335],{"href":1334},"\u002Fde","PlanElec öffnen und Verlegearten eintragen →",[16,1337,1338],{},[20,1339,1340],{},"Regelgrundlage: AREI\u002FRGIE Buch 1 V06 — Abschnitte 2.6.1, 2.7.1, 2.7.2, 5.2.2, 5.2.8, Unterabschnitte 3.1.2.1, 3.1.2.2, 3.1.2.3, 4.3.3.5, 4.4.1.4 mit Tabelle 4.11, 5.2.1.2, 5.2.3.1, 5.2.7.2, 5.2.7.3 und Abschnitt 5.2.9 mit den Unterabschnitten 5.2.9.1 bis 5.2.9.15. Maßgeblich bleiben die amtliche Fassung, der reale Anlagenzustand und die Kontrolle der zugelassenen Stelle.",{"title":1342,"searchDepth":1343,"depth":1343,"links":1344},"",2,[1345,1346,1347,1348,1349,1350,1351,1352,1353,1354,1355,1356,1357],{"id":13,"depth":1343,"text":14},{"id":404,"depth":1343,"text":405},{"id":442,"depth":1343,"text":443},{"id":541,"depth":1343,"text":542},{"id":604,"depth":1343,"text":605},{"id":704,"depth":1343,"text":705},{"id":721,"depth":1343,"text":722},{"id":815,"depth":1343,"text":816},{"id":839,"depth":1343,"text":840},{"id":974,"depth":1343,"text":975},{"id":1165,"depth":1343,"text":1166},{"id":1222,"depth":1343,"text":1223},{"id":1303,"depth":1343,"text":1304},"guide","2026-08-31","Die siebzehn Verlegearten aus Unterabschnitt 5.2.2.1, ihre besonderen Regeln in Abschnitt 5.2.9, der Einfluss auf die Strombelastbarkeit und die Frage, wo die Angabe verbindlich hingehört — mit AREI-Artikel neben jeder Aussage.","md","de",{},true,"\u002Fblog\u002Finstallation-methods-arei.de","12 min",12,{"title":5,"description":1360},"verlegearten-arei-eindrahtschema","blog\u002Finstallation-methods-arei.de",[1372,1373,1374,1375,1376,1377,1378,1379],"AREI","RGIE","Verlegearten","Eindrahtschema","Strombelastbarkeit","Kabelverlegung","Installationszonen","Belgien","AwWeLzH3tJGT587cHlVl_Aevj08x8fCZWFm6HWpLMBA",[1382,2333,3626,4947],{"id":4,"title":5,"articleId":6,"body":1383,"category":1358,"date":1359,"description":1360,"extension":1361,"lastUpdated":1359,"locale":1362,"meta":2330,"navigation":1364,"path":1365,"publishDate":1359,"readTime":1366,"refreshInterval":1367,"seo":2331,"slug":1369,"stem":1370,"tags":2332,"__hash__":1380},{"type":8,"value":1384,"toc":2315},[1385,1387,1401,1405,1657,1661,1663,1671,1683,1685,1689,1739,1743,1753,1755,1757,1769,1777,1789,1791,1793,1853,1857,1861,1863,1869,1871,1873,1879,1885,1891,1905,1917,1927,1929,1935,1937,1941,1943,1945,2029,2043,2045,2047,2183,2187,2189,2191,2193,2227,2229,2283,2285,2307,2311],[11,1386,14],{"id":13},[16,1388,18,1389,23,1391,27,1393,31,1395,35,1397,40,1399,44],{},[20,1390,22],{},[20,1392,26],{},[20,1394,30],{},[20,1396,34],{},[37,1398,39],{},[20,1400,43],{},[16,1402,47,1403,51],{},[20,1404,50],{},[53,1406,1407,1421],{},[56,1408,1409],{},[59,1410,1411,1415,1417,1419],{},[62,1412,64,1413,68],{},[20,1414,67],{},[62,1416,71],{},[62,1418,74],{},[62,1420,77],{},[79,1422,1423,1437,1449,1461,1473,1485,1497,1509,1521,1533,1545,1557,1569,1583,1597,1609,1621,1633,1645],{},[59,1424,1425,1427,1429,1431],{},[84,1426,22],{},[84,1428,88],{},[84,1430,91],{},[84,1432,1433,97,1435,68],{},[20,1434,96],{},[20,1436,100],{},[59,1438,1439,1441,1443,1445],{},[84,1440,105],{},[84,1442,108],{},[84,1444,111],{},[84,1446,1447,117],{},[20,1448,116],{},[59,1450,1451,1453,1455,1457],{},[84,1452,122],{},[84,1454,125],{},[84,1456,128],{},[84,1458,1459],{},[20,1460,116],{},[59,1462,1463,1465,1467,1469],{},[84,1464,137],{},[84,1466,140],{},[84,1468,143],{},[84,1470,1471],{},[20,1472,116],{},[59,1474,1475,1477,1479,1481],{},[84,1476,152],{},[84,1478,155],{},[84,1480,158],{},[84,1482,1483],{},[20,1484,163],{},[59,1486,1487,1489,1491,1493],{},[84,1488,168],{},[84,1490,171],{},[84,1492,174],{},[84,1494,1495,180],{},[20,1496,179],{},[59,1498,1499,1501,1503,1505],{},[84,1500,185],{},[84,1502,188],{},[84,1504,191],{},[84,1506,1507],{},[20,1508,196],{},[59,1510,1511,1513,1515,1517],{},[84,1512,201],{},[84,1514,204],{},[84,1516,207],{},[84,1518,1519,213],{},[20,1520,212],{},[59,1522,1523,1525,1527,1529],{},[84,1524,218],{},[84,1526,221],{},[84,1528,224],{},[84,1530,1531,229],{},[20,1532,179],{},[59,1534,1535,1537,1539,1541],{},[84,1536,234],{},[84,1538,237],{},[84,1540,240],{},[84,1542,1543,246],{},[20,1544,245],{},[59,1546,1547,1549,1551,1553],{},[84,1548,251],{},[84,1550,254],{},[84,1552,257],{},[84,1554,1555],{},[20,1556,262],{},[59,1558,1559,1561,1563,1565],{},[84,1560,267],{},[84,1562,270],{},[84,1564,273],{},[84,1566,1567],{},[20,1568,278],{},[59,1570,1571,1573,1575,1577],{},[84,1572,283],{},[84,1574,286],{},[84,1576,289],{},[84,1578,1579,295,1581],{},[20,1580,294],{},[20,1582,298],{},[59,1584,1585,1587,1589,1591],{},[84,1586,303],{},[84,1588,306],{},[84,1590,309],{},[84,1592,1593,295,1595],{},[20,1594,294],{},[20,1596,298],{},[59,1598,1599,1601,1603,1605],{},[84,1600,320],{},[84,1602,323],{},[84,1604,326],{},[84,1606,1607,332],{},[20,1608,331],{},[59,1610,1611,1613,1615,1617],{},[84,1612,337],{},[84,1614,340],{},[84,1616,343],{},[84,1618,1619],{},[20,1620,348],{},[59,1622,1623,1625,1627,1629],{},[84,1624,353],{},[84,1626,356],{},[84,1628,359],{},[84,1630,1631],{},[20,1632,364],{},[59,1634,1635,1637,1639,1641],{},[84,1636,16],{},[84,1638,371],{},[84,1640,374],{},[84,1642,1643],{},[20,1644,379],{},[59,1646,1647,1649,1651,1653],{},[84,1648,26],{},[84,1650,386],{},[84,1652,389],{},[84,1654,1655],{},[20,1656,394],{},[16,1658,397,1659,401],{},[20,1660,400],{},[11,1662,405],{"id":404},[16,1664,408,1665,411,1667,414,1669,418],{},[20,1666,185],{},[20,1668,320],{},[37,1670,417],{},[16,1672,421,1673,424,1675,428,1677,424,1679,434,1681,439],{},[20,1674,185],{},[20,1676,427],{},[20,1678,320],{},[20,1680,433],{},[22,1682,438],{"href":437},[11,1684,443],{"id":442},[16,1686,1687,448],{},[20,1688,50],{},[53,1690,1691,1701],{},[56,1692,1693],{},[59,1694,1695,1699],{},[62,1696,457,1697],{},[20,1698,460],{},[62,1700,463],{},[79,1702,1703,1711,1717,1723,1731],{},[59,1704,1705,1707],{},[84,1706,470],{},[84,1708,473,1709,68],{},[20,1710,476],{},[59,1712,1713,1715],{},[84,1714,481],{},[84,1716,484],{},[59,1718,1719,1721],{},[84,1720,489],{},[84,1722,492],{},[59,1724,1725,1727],{},[84,1726,497],{},[84,1728,473,1729,68],{},[20,1730,476],{},[59,1732,1733,1735],{},[84,1734,506],{},[84,1736,509,1737],{},[20,1738,512],{},[16,1740,515,1741,518],{},[20,1742,460],{},[16,1744,521,1745,525,1747,529,1749,533,1751,538],{},[20,1746,524],{},[37,1748,528],{},[20,1750,532],{},[22,1752,537],{"href":536},[11,1754,542],{"id":541},[16,1756,545],{},[16,1758,1759,551,1761,555,1763,559,1765,563,1767,567],{},[37,1760,550],{},[37,1762,554],{},[20,1764,558],{},[20,1766,562],{},[20,1768,566],{},[16,1770,1771,573,1773,577,1775,581],{},[37,1772,572],{},[20,1774,576],{},[20,1776,580],{},[16,1778,1779,587,1781,591,1783,594,1785,598,1787,601],{},[37,1780,586],{},[37,1782,590],{},[20,1784,512],{},[20,1786,597],{},[20,1788,460],{},[11,1790,605],{"id":604},[16,1792,608],{},[53,1794,1795,1805],{},[56,1796,1797],{},[59,1798,1799,1801,1803],{},[62,1800,617],{},[62,1802,620],{},[62,1804,623],{},[79,1806,1807,1819,1831,1843],{},[59,1808,1809,1811,1815],{},[84,1810,630],{},[84,1812,1813,636],{},[37,1814,635],{},[84,1816,1817],{},[20,1818,476],{},[59,1820,1821,1823,1827],{},[84,1822,645],{},[84,1824,648,1825,652],{},[37,1826,651],{},[84,1828,1829],{},[20,1830,657],{},[59,1832,1833,1835,1839],{},[84,1834,662],{},[84,1836,1837,667],{},[37,1838,635],{},[84,1840,1841],{},[20,1842,672],{},[59,1844,1845,1847,1849],{},[84,1846,677],{},[84,1848,680],{},[84,1850,683,1851],{},[20,1852,686],{},[16,1854,689,1855,693],{},[20,1856,692],{},[16,1858,696,1859,701],{},[22,1860,700],{"href":699},[11,1862,705],{"id":704},[16,1864,708,1865,712,1867,44],{},[37,1866,711],{},[20,1868,715],{},[16,1870,718],{},[11,1872,722],{"id":721},[16,1874,725,1875,729,1877,732],{},[20,1876,728],{},[20,1878,433],{},[16,1880,735,1881,739,1883,44],{},[37,1882,738],{},[20,1884,742],{},[16,1886,735,1887,748,1889,752],{},[37,1888,747],{},[20,1890,751],{},[754,1892,1893,1895,1897,1899,1901,1903],{},[757,1894,759],{},[757,1896,762],{},[757,1898,765],{},[757,1900,768],{},[757,1902,771],{},[757,1904,774],{},[16,1906,777,1907,780,1909,784,1911,788,1913,792,1915,44],{},[20,1908,427],{},[20,1910,783],{},[20,1912,787],{},[20,1914,791],{},[20,1916,787],{},[16,1918,797,1919,801,1921,805,1923,809,1925,812],{},[37,1920,800],{},[20,1922,804],{},[20,1924,808],{},[20,1926,34],{},[11,1928,816],{"id":815},[16,1930,1931,822,1933,826],{},[20,1932,821],{},[37,1934,825],{},[16,1936,829],{},[16,1938,832,1939,836],{},[20,1940,835],{},[11,1942,840],{"id":839},[16,1944,843],{},[53,1946,1947,1957],{},[56,1948,1949],{},[59,1950,1951,1953,1955],{},[62,1952,71],{},[62,1954,854],{},[62,1956,623],{},[79,1958,1959,1969,1979,1989,1999,2009,2019],{},[59,1960,1961,1963,1965],{},[84,1962,863],{},[84,1964,825],{},[84,1966,1967],{},[20,1968,870],{},[59,1970,1971,1973,1975],{},[84,1972,875],{},[84,1974,825],{},[84,1976,1977],{},[20,1978,179],{},[59,1980,1981,1983,1985],{},[84,1982,886],{},[84,1984,825],{},[84,1986,1987],{},[20,1988,245],{},[59,1990,1991,1993,1995],{},[84,1992,897],{},[84,1994,900],{},[84,1996,1997],{},[20,1998,245],{},[59,2000,2001,2003,2005],{},[84,2002,909],{},[84,2004,912],{},[84,2006,2007],{},[20,2008,917],{},[59,2010,2011,2013,2015],{},[84,2012,922],{},[84,2014,925],{},[84,2016,2017],{},[20,2018,930],{},[59,2020,2021,2023,2025],{},[84,2022,935],{},[84,2024,938],{},[84,2026,2027],{},[20,2028,294],{},[16,2030,945,2031,949,2033,953,2035,957,2037,961,2039,966,2041,971],{},[37,2032,948],{},[37,2034,952],{},[20,2036,956],{},[20,2038,960],{},[22,2040,965],{"href":964},[22,2042,970],{"href":969},[11,2044,975],{"id":974},[16,2046,978],{},[53,2048,2049,2059],{},[56,2050,2051],{},[59,2052,2053,2055,2057],{},[62,2054,987],{},[62,2056,990],{},[62,2058,993],{},[79,2060,2061,2071,2083,2093,2103,2113,2123,2133,2143,2153,2163,2173],{},[59,2062,2063,2065,2067],{},[84,2064,1000],{},[84,2066,1003],{},[84,2068,2069],{},[20,2070,1008],{},[59,2072,2073,2075,2077],{},[84,2074,1013],{},[84,2076,1016],{},[84,2078,2079,1021,2081],{},[20,2080,1008],{},[20,2082,1024],{},[59,2084,2085,2087,2089],{},[84,2086,1029],{},[84,2088,1032],{},[84,2090,2091],{},[20,2092,1037],{},[59,2094,2095,2097,2099],{},[84,2096,1042],{},[84,2098,1045],{},[84,2100,2101],{},[20,2102,1050],{},[59,2104,2105,2107,2109],{},[84,2106,1055],{},[84,2108,1058],{},[84,2110,2111],{},[20,2112,196],{},[59,2114,2115,2117,2119],{},[84,2116,1067],{},[84,2118,1070],{},[84,2120,2121],{},[20,2122,196],{},[59,2124,2125,2127,2129],{},[84,2126,1079],{},[84,2128,1082],{},[84,2130,2131],{},[20,2132,1087],{},[59,2134,2135,2137,2139],{},[84,2136,1092],{},[84,2138,1095],{},[84,2140,2141],{},[20,2142,1100],{},[59,2144,2145,2147,2149],{},[84,2146,1105],{},[84,2148,1108],{},[84,2150,2151],{},[20,2152,1113],{},[59,2154,2155,2157,2159],{},[84,2156,1118],{},[84,2158,1121],{},[84,2160,2161],{},[20,2162,1126],{},[59,2164,2165,2167,2169],{},[84,2166,1131],{},[84,2168,1134],{},[84,2170,2171],{},[20,2172,1139],{},[59,2174,2175,2177,2179],{},[84,2176,1144],{},[84,2178,1147],{},[84,2180,2181],{},[20,2182,1152],{},[16,2184,1155,2185,1159],{},[37,2186,1158],{},[16,2188,1162],{},[11,2190,1166],{"id":1165},[16,2192,1169],{},[754,2194,2195,2201,2207,2215,2219],{},[757,2196,1174,2197,1178,2199,1181],{},[37,2198,1177],{},[20,2200,524],{},[757,2202,1174,2203,1186,2205,1189],{},[37,2204,1177],{},[20,2206,804],{},[757,2208,1174,2209,1194,2211,1021,2213,1199],{},[37,2210,1158],{},[20,2212,298],{},[20,2214,960],{},[757,2216,1174,2217,1204],{},[37,2218,1177],{},[757,2220,1207,2221,1211,2223,1215,2225,971],{},[37,2222,1210],{},[37,2224,1214],{},[22,2226,1219],{"href":1218},[11,2228,1223],{"id":1222},[754,2230,2231,2239,2245,2251,2257,2263,2271,2277],{},[757,2232,2233,1231,2235,1234,2237,1237],{},[37,2234,1230],{},[20,2236,179],{},[20,2238,245],{},[757,2240,2241,1243,2243,971],{},[37,2242,1242],{},[20,2244,804],{},[757,2246,2247,1251,2249,44],{},[37,2248,1250],{},[20,2250,1254],{},[757,2252,2253,1260,2255,1264],{},[37,2254,1259],{},[20,2256,1263],{},[757,2258,2259,1270,2261,44],{},[37,2260,1269],{},[20,2262,1273],{},[757,2264,2265,1279,2267,1021,2269,44],{},[37,2266,1278],{},[20,2268,298],{},[20,2270,960],{},[757,2272,2273,1289,2275,44],{},[37,2274,1288],{},[20,2276,116],{},[757,2278,2279,1297,2281,1300],{},[37,2280,1296],{},[20,2282,476],{},[11,2284,1304],{"id":1303},[754,2286,2287,2291,2295,2299,2303],{},[757,2288,2289],{},[22,2290,537],{"href":536},[757,2292,2293],{},[22,2294,700],{"href":699},[757,2296,2297],{},[22,2298,1319],{"href":964},[757,2300,2301],{},[22,2302,438],{"href":437},[757,2304,2305],{},[22,2306,1329],{"href":1328},[16,2308,2309],{},[22,2310,1335],{"href":1334},[16,2312,2313],{},[20,2314,1340],{},{"title":1342,"searchDepth":1343,"depth":1343,"links":2316},[2317,2318,2319,2320,2321,2322,2323,2324,2325,2326,2327,2328,2329],{"id":13,"depth":1343,"text":14},{"id":404,"depth":1343,"text":405},{"id":442,"depth":1343,"text":443},{"id":541,"depth":1343,"text":542},{"id":604,"depth":1343,"text":605},{"id":704,"depth":1343,"text":705},{"id":721,"depth":1343,"text":722},{"id":815,"depth":1343,"text":816},{"id":839,"depth":1343,"text":840},{"id":974,"depth":1343,"text":975},{"id":1165,"depth":1343,"text":1166},{"id":1222,"depth":1343,"text":1223},{"id":1303,"depth":1343,"text":1304},{},{"title":5,"description":1360},[1372,1373,1374,1375,1376,1377,1378,1379],{"id":2334,"title":2335,"articleId":6,"body":2336,"category":1358,"date":1359,"description":3612,"extension":1361,"lastUpdated":1359,"locale":3613,"meta":3614,"navigation":1364,"path":3615,"publishDate":1359,"readTime":1366,"refreshInterval":1367,"seo":3616,"slug":6,"stem":3617,"tags":3618,"__hash__":3625},"blog\u002Fblog\u002Finstallation-methods-arei.en.md","Installation methods under the AREI: which entry belongs on the single-line diagram?",{"type":8,"value":2337,"toc":3597},[2338,2342,2366,2373,2680,2687,2691,2704,2725,2729,2735,2797,2803,2822,2826,2829,2851,2864,2884,2888,2891,2969,2976,2984,2988,2998,3001,3005,3015,3025,3035,3055,3075,3093,3097,3107,3110,3117,3121,3124,3221,3248,3252,3255,3405,3412,3419,3423,3426,3477,3481,3557,3561,3586,3592],[11,2339,2341],{"id":2340},"which-installation-methods-does-the-arei-recognise-and-which-one-belongs-on-the-diagram","Which installation methods does the AREI recognise — and which one belongs on the diagram?",[16,2343,2344,2345,2347,2348,2350,2351,2354,2355,2358,2359,2362,2363,44],{},"The AREI lists the permitted installation methods for low-voltage wiring exhaustively: seventeen letters, ",[20,2346,22],{}," to ",[20,2349,26],{},", in ",[20,2352,2353],{},"sub-section 5.2.2.1"," — overhead lines, buried cables, surface and concealed wiring, skirtings, trunking and troughs, all the way to heating cables in ceilings and floors. For most of these methods, ",[20,2356,2357],{},"section 5.2.9"," adds its own binding rules. And the chosen method is not the installer's private business: the single-line diagram of a domestic installation must state, alongside type, cross-section and number of conductors, ",[37,2360,2361],{},"the installation method of the wiring"," (",[20,2364,2365],{},"sub-section 3.1.2.2 point a",[16,2367,2368,2369,2372],{},"The reason sits elsewhere in the regulation. The current-carrying capacity IZ of a cable depends, among other things, on \"the installation method and the environment of the wiring\" (",[20,2370,2371],{},"sub-section 4.4.1.4","). Without the installation method you cannot judge whether a cross-section suits the circuit — which is exactly why it is on the diagram.",[53,2374,2375,2393],{},[56,2376,2377],{},[59,2378,2379,2384,2387,2390],{},[62,2380,2381,2382,68],{},"Letter (",[20,2383,67],{},[62,2385,2386],{},"Installation method",[62,2388,2389],{},"Typical residential use",[62,2391,2392],{},"Specific rules",[79,2394,2395,2413,2429,2443,2457,2472,2487,2501,2516,2531,2546,2560,2574,2592,2608,2623,2637,2651,2666],{},[59,2396,2397,2399,2402,2405],{},[84,2398,22],{},[84,2400,2401],{},"overhead lines",[84,2403,2404],{},"supply to an outbuilding",[84,2406,2407,2409,2410,68],{},[20,2408,96],{}," (refers to book 3, ",[20,2411,2412],{},"chapter 7.1",[59,2414,2415,2417,2420,2423],{},[84,2416,105],{},[84,2418,2419],{},"directly buried",[84,2421,2422],{},"garden socket, carport",[84,2424,2425,2428],{},[20,2426,2427],{},"5.2.9.2 point a",": at least 0.60 m deep, cables only",[59,2430,2431,2433,2436,2439],{},[84,2432,122],{},[84,2434,2435],{},"buried with mechanical protection",[84,2437,2438],{},"cable under a warning tape",[84,2440,2441],{},[20,2442,2427],{},[59,2444,2445,2447,2450,2453],{},[84,2446,137],{},[84,2448,2449],{},"buried in ducts",[84,2451,2452],{},"crossing under a driveway or terrace",[84,2454,2455],{},[20,2456,2427],{},[59,2458,2459,2461,2464,2467],{},[84,2460,152],{},[84,2462,2463],{},"contact lines for rolling or sliding contacts",[84,2465,2466],{},"not relevant in housing",[84,2468,2469],{},[20,2470,2471],{},"5.2.1.4 point a",[59,2473,2474,2476,2479,2482],{},[84,2475,168],{},[84,2477,2478],{},"surface-mounted",[84,2480,2481],{},"visible XVB in cellar, garage, plant room",[84,2483,2484,2486],{},[20,2485,179],{},": cables only; wall clearance ≤ 0.3 × outer diameter",[59,2488,2489,2491,2494,2497],{},[84,2490,185],{},[84,2492,2493],{},"in concealed conduits",[84,2495,2496],{},"new-build standard: VOB inside Preflex",[84,2498,2499],{},[20,2500,196],{},[59,2502,2503,2505,2508,2511],{},[84,2504,201],{},[84,2506,2507],{},"in mouldings, skirtings and architraves",[84,2509,2510],{},"renovation, visible trunking",[84,2512,2513,2515],{},[20,2514,212],{},": insulated conductors or single-core cables only",[59,2517,2518,2520,2523,2526],{},[84,2519,218],{},[84,2521,2522],{},"in free air with clips, or on trays, ladders, brackets and similar supports",[84,2524,2525],{},"plant room, boiler room",[84,2527,2528,2530],{},[20,2529,179],{},": clearance from any wall ≥ 0.3 × outer diameter",[59,2532,2533,2535,2538,2541],{},[84,2534,234],{},[84,2536,2537],{},"in trunking and troughs",[84,2539,2540],{},"distribution run in a plant room",[84,2542,2543,2545],{},[20,2544,245],{},": troughs take cables only",[59,2547,2548,2550,2553,2556],{},[84,2549,251],{},[84,2551,2552],{},"in ducts above floor level",[84,2554,2555],{},"route above the floor",[84,2557,2558],{},[20,2559,262],{},[59,2561,2562,2564,2567,2570],{},[84,2563,267],{},[84,2565,2566],{},"in open, closed or sand-filled channels",[84,2568,2569],{},"floor channel, industrial use",[84,2571,2572],{},[20,2573,278],{},[59,2575,2576,2578,2581,2584],{},[84,2577,283],{},[84,2579,2580],{},"in structural voids, recesses and manufactured blocks",[84,2582,2583],{},"hollow blocks, suspended ceiling",[84,2585,2586,2588,2589],{},[20,2587,294],{}," and ",[20,2590,2591],{},"4.3.3.5 point b",[59,2593,2594,2596,2599,2602],{},[84,2595,303],{},[84,2597,2598],{},"behind wall panels",[84,2600,2601],{},"drywall, timber frame",[84,2603,2604,2588,2606],{},[20,2605,294],{},[20,2607,2591],{},[59,2609,2610,2612,2615,2618],{},[84,2611,320],{},[84,2613,2614],{},"directly concealed, without conduits",[84,2616,2617],{},"XVB straight into the chase",[84,2619,2620,2622],{},[20,2621,331],{},": installation zones, concrete ≥ 3 cm, plaster ≥ 0.4 cm",[59,2624,2625,2627,2630,2633],{},[84,2626,337],{},[84,2628,2629],{},"in busbar trunking systems",[84,2631,2632],{},"rare in housing",[84,2634,2635],{},[20,2636,348],{},[59,2638,2639,2641,2644,2647],{},[84,2640,353],{},[84,2642,2643],{},"on insulators",[84,2645,2646],{},"legacy installations",[84,2648,2649],{},[20,2650,364],{},[59,2652,2653,2655,2658,2661],{},[84,2654,16],{},[84,2656,2657],{},"submerged in water",[84,2659,2660],{},"swimming-pool equipment",[84,2662,2663],{},[20,2664,2665],{},"5.2.2.1 point p",[59,2667,2668,2670,2673,2676],{},[84,2669,26],{},[84,2671,2672],{},"in ceilings, floors and walls for heating cables and panels",[84,2674,2675],{},"underfloor heating, heating mats",[84,2677,2678],{},[20,2679,394],{},[16,2681,2682,2683,2686],{},"Other methods are not forbidden, but they fall under the residual clause: they must comply with \"the relevant rules of the trade\" (",[20,2684,2685],{},"sub-section 5.2.2.4","). Working outside the list therefore means leaving the territory for which the AREI itself states a rule.",[11,2688,2690],{"id":2689},"what-separates-point-e-from-point-m","What separates point e from point m?",[16,2692,2693,2694,2696,2697,2699,2700,2703],{},"This is the pair that gets confused most often, because in everyday speech both are simply \"concealed\". The difference is the conduit. Point ",[20,2695,185],{}," is literally \"in concealed conduits\" — the Dutch text says \"in verzonken buizen\", the French \"sous conduits encastrés\". Point ",[20,2698,320],{}," is expressly \"directly concealed, ",[37,2701,2702],{},"without"," conduits\".",[16,2705,2706,2707,2709,2710,2713,2714,2709,2716,2719,2720,2724],{},"That is not wordplay but the boundary between two sets of rules. Point ",[20,2708,185],{}," is governed by ",[20,2711,2712],{},"sub-section 5.2.9.3"," with the conduit rules: bending radii, conductors that remain drawable and removable at all times, no connections inside the conduit. Point ",[20,2715,320],{},[20,2717,2718],{},"sub-section 5.2.9.10"," with the installation zones and the minimum covers. Which material to choose in each case, and what it costs, is compared in ",[22,2721,2723],{"href":2722},"\u002Fen\u002Fblog\u002Fpreflex-vs-open-wiring","Preflex versus open wiring","; this article describes the systematics that both variants sit inside.",[11,2726,2728],{"id":2727},"why-does-the-installation-method-govern-current-carrying-capacity","Why does the installation method govern current-carrying capacity?",[16,2730,2731,2734],{},[20,2732,2733],{},"Sub-section 4.4.1.4"," names five quantities that IZ depends on. The installation method is one of them, and it is the only one you cannot read off the cable itself.",[53,2736,2737,2749],{},[56,2738,2739],{},[59,2740,2741,2746],{},[62,2742,2743,2744],{},"Quantity per ",[20,2745,460],{},[62,2747,2748],{},"What it means on the plan",[79,2750,2751,2762,2770,2778,2787],{},[59,2752,2753,2756],{},[84,2754,2755],{},"conductor cross-section",[84,2757,2758,2759,68],{},"entry on the single-line diagram (",[20,2760,2761],{},"3.1.2.2 point a",[59,2763,2764,2767],{},[84,2765,2766],{},"conductor insulation",[84,2768,2769],{},"cable type, for example XVB or VOB",[59,2771,2772,2775],{},[84,2773,2774],{},"construction of the wiring",[84,2776,2777],{},"single- or multi-core, armouring, screen",[59,2779,2780,2783],{},[84,2781,2782],{},"installation method and environment",[84,2784,2758,2785,68],{},[20,2786,2761],{},[59,2788,2789,2792],{},[84,2790,2791],{},"ambient temperature",[84,2793,2794,2795],{},"where the cable runs, see ",[20,2796,512],{},[16,2798,2799,2800,2802],{},"The calculation itself is not in the AREI. The text only says that current-carrying capacity \"is calculated in accordance with the rules of the trade\" (",[20,2801,460],{},"), and that the competent ministers may set out further rules. In practice the tables and correction factors therefore come from the NBN HD 60364-5-52 series, not from the AREI.",[16,2804,2805,2806,2809,2810,2813,2814,2817,2818,971],{},"What the AREI does fix is frequently mistaken for that: ",[20,2807,2808],{},"table 4.11"," gives, for domestic installations, the ",[37,2811,2812],{},"maximum"," rated current per conductor cross-section, separately for the fuse and for the circuit breaker: at 1.5 mm² 10 A and 16 A, at 2.5 mm² 16 A and 20 A, at 4 mm² 20 A and 25 A, at 6 mm² 32 A and 40 A, at 10 mm² 50 A and 63 A. That table knows nothing about the installation method. It is a ceiling, not a clearance: the condition IZ ≥ IB from ",[20,2815,2816],{},"sub-section 5.2.1.2 point a"," has to be met on top of it. The cross-section-to-protection pairing is covered in ",[22,2819,2821],{"href":2820},"\u002Fen\u002Fblog\u002Fcable-cross-section-breaker","Cable cross-section and breaker rating",[11,2823,2825],{"id":2824},"what-do-grouping-ambient-temperature-and-thermal-insulation-do-to-the-capacity","What do grouping, ambient temperature and thermal insulation do to the capacity?",[16,2827,2828],{},"All three lower IZ, and in all three cases the AREI supplies the boundary condition, not the factor.",[16,2830,2831,2834,2835,2838,2839,2842,2843,2846,2847,2850],{},[37,2832,2833],{},"Grouping."," The AREI defines the threshold precisely: a cable or insulated conductor counts as ",[37,2836,2837],{},"installed separately"," when it lies at least 20 mm away from any other cable or insulated conductor (",[20,2840,2841],{},"section 2.7.1","). Anything closer is installed \"in bunches or in a flat layer\". That distinction has a direct consequence in the AREI — but for fire propagation, not for heating: separately installed conductors and cables must have at least characteristic F1 or class Eca (",[20,2844,2845],{},"sub-section 5.2.7.2","); in bunches or a flat layer, at least F2 or class Cca (",[20,2848,2849],{},"sub-section 5.2.7.3","), and that applies \"regardless of the distance over which\" they are actually bunched. The thermal grouping factor itself again follows from the rules of the trade.",[16,2852,2853,573,2856,2859,2860,2863],{},[37,2854,2855],{},"Ambient temperature.",[20,2857,2858],{},"Sub-section 5.2.3.1"," requires wiring to suit both the lowest and the highest local ambient temperature and to be installed only within the temperature range stated by the manufacturer. ",[20,2861,2862],{},"Section 5.2.8"," adds to this: wiring must not be exposed to harmful temperatures near heating pipes, hot-air ducts or flues, and must keep sufficient distance or be separated by a heat shield. Routing a cable alongside the heating manifold changes its thermal environment — and that environment is part of the same entry as the installation method.",[16,2865,2866,2869,2870,2873,2874,2876,2877,2880,2881,2883],{},[37,2867,2868],{},"Thermal insulation."," Here an honest statement is due: the AREI contains ",[37,2871,2872],{},"no"," reduction factor of its own for cables in or under thermal insulation. \"Thermal insulation\" appears in the regulation as a precaution for temperatures below −25 °C (",[20,2875,512],{},") and in the chapter on heating panels, where insulating material in contact with the heating installation must be non-combustible (",[20,2878,2879],{},"5.2.9.13 point b.5","). A cable running through an insulated pitched roof therefore falls under \"installation method and environment\" in ",[20,2882,460],{}," and is assessed by the rules of the trade — not by an AREI table that does not exist.",[11,2885,2887],{"id":2886},"where-does-the-entry-belong-single-line-diagram-position-plan-or-bill-of-materials","Where does the entry belong: single-line diagram, position plan or bill of materials?",[16,2889,2890],{},"These three documents have clearly separated mandatory content in the AREI.",[53,2892,2893,2906],{},[56,2894,2895],{},[59,2896,2897,2900,2903],{},[62,2898,2899],{},"Document",[62,2901,2902],{},"Installation method required?",[62,2904,2905],{},"Reference",[79,2907,2908,2923,2940,2955],{},[59,2909,2910,2913,2919],{},[84,2911,2912],{},"single-line diagram (domestic)",[84,2914,2915,2918],{},[37,2916,2917],{},"yes",", explicitly",[84,2920,2921],{},[20,2922,2761],{},[59,2924,2925,2928,2935],{},[84,2926,2927],{},"position plan (domestic)",[84,2929,2930,2931,2934],{},"no — it shows the ",[37,2932,2933],{},"position"," of the components",[84,2936,2937],{},[20,2938,2939],{},"3.1.2.3 point a",[59,2941,2942,2945,2950],{},[84,2943,2944],{},"circuit diagram (non-domestic)",[84,2946,2947,2949],{},[37,2948,2917],{},", together with length and conductor count",[84,2951,2952],{},[20,2953,2954],{},"3.1.2.2 point b",[59,2956,2957,2960,2963],{},[84,2958,2959],{},"bill of materials",[84,2961,2962],{},"not prescribed",[84,2964,2965,2966],{},"permitted as an annex under ",[20,2967,2968],{},"3.1.2.1 point c",[16,2970,2971,2972,2975],{},"The bill of materials is not a mandatory document under the AREI. ",[20,2973,2974],{},"Sub-section 3.1.2.1 point c"," merely allows diagrams and plans to be supplemented by documents \"describing in more detail the various characteristics of the electrical equipment and\u002For products\". A cable list carrying the installation method per run is exactly such an annex: useful for pricing and execution, but it does not remove the obligation to carry the entry on the single-line diagram itself.",[16,2977,2978,2979,2983],{},"How diagram and position plan divide the work is set out in ",[22,2980,2982],{"href":2981},"\u002Fen\u002Fblog\u002Fcable-routes-and-lengths","Cable routes and cable lengths",", which also explains why the length is mandatory only on the non-domestic circuit diagram.",[11,2985,2987],{"id":2986},"when-does-the-installation-method-change-within-one-cable-run","When does the installation method change within one cable run?",[16,2989,2990,2991,2994,2995,44],{},"A cable run rarely has a single installation method. Out of the board, through the wall, across the ceiling, into the ground and back up an outside wall — that is four. The AREI has a term for this. The ",[37,2992,2993],{},"origin of the circuit"," is either the start of the wiring \"or the point where the cross-section, nature or construction of the wiring, or its installation method, changes\" (",[20,2996,2997],{},"section 2.6.1",[16,2999,3000],{},"In practice: every change of method opens a separate stretch for assessment. For sizing, the least favourable one governs — a cable that runs two metres inside a bundle of conduits before continuing freely across a ceiling is not sized on the free stretch. For the diagram: every method that occurs must be documented, not just the longest one.",[11,3002,3004],{"id":3003},"which-rules-apply-to-concealed-wiring","Which rules apply to concealed wiring?",[16,3006,3007,3008,3011,3012,3014],{},"For direct concealment without conduit (",[20,3009,3010],{},"point m","), ",[20,3013,2718],{}," is the governing provision, and it is unusually concrete.",[16,3016,3017,3018,3021,3022,44],{},"Wiring embedded in ",[37,3019,3020],{},"concrete or cement"," is covered by a layer of at least 3 cm; conductors with basic insulation only may not be embedded there at all (",[20,3023,3024],{},"point a",[16,3026,3027,3028,3031,3032,752],{},"Wiring concealed without conduit ",[37,3029,3030],{},"in the walls of rooms"," must additionally stay within the installation zones (",[20,3033,3034],{},"point b",[754,3036,3037,3040,3043,3046,3049,3052],{},[757,3038,3039],{},"the route consists exclusively of horizontal and vertical stretches, horizontal runs in a ceiling being perpendicular to the vertical walls;",[757,3041,3042],{},"horizontal runs lie 25 to 35 cm above the floor or below the ceiling, and likewise 25 to 35 cm above the underside of window lintels, provided they then remain at least 25 cm below the ceiling;",[757,3044,3045],{},"vertical runs lie as close as possible to a corner of the room, or 10 to 20 cm from door frames and architraves;",[757,3047,3048],{},"outside these zones, only a vertical run above a visible machine or appliance is permitted;",[757,3050,3051],{},"the wiring is subjected to no mechanical stress, neither during installation nor afterwards, and is fixed to the walls without damage;",[757,3053,3054],{},"the covering plaster layer is at least 0.4 cm thick.",[16,3056,3057,3058,3060,3061,3064,3065,3068,3069,3072,3073,44],{},"For conduits, ",[20,3059,2712],{}," applies instead: conductors or cables must remain drawable and removable at all times (",[20,3062,3063],{},"point e","), connections inside the conduit are forbidden (",[20,3066,3067],{},"point f","), and in embedded conduits tees and elbows are not permitted while conductors stay accessible in junction, branch and draw boxes (",[20,3070,3071],{},"point i.2","). Conduits made of combustible material may only be used when embedded at least 3 cm deep in non-combustible materials (",[20,3074,3067],{},[16,3076,3077,3078,3081,3082,3085,3086,3089,3090,3092],{},"One important exception: for ",[37,3079,3080],{},"extra-low voltage installations",", the zone pattern of ",[20,3083,3084],{},"5.2.9.10 point b"," expressly does not apply (",[20,3087,3088],{},"sub-section 5.2.9.15 point b","). Bus, bell and control wiring at ELV therefore need not follow the zones — the remaining rules of ",[20,3091,2357],{}," still do.",[11,3094,3096],{"id":3095},"what-applies-to-buried-cables","What applies to buried cables?",[16,3098,3099,3102,3103,3106],{},[20,3100,3101],{},"Sub-section 5.2.9.2 point a"," is one of the sharpest provisions in the chapter. In the ground and in inaccessible underground ducts, only ",[37,3104,3105],{},"cables"," may be installed, independent protective conductors excepted. The minimum depth is 0.60 m measured from the ground surface, \"unless technically impossible\". Where that depth cannot be reached, protection is provided instead by a continuous or sealed duct of durable, resistant material.",[16,3108,3109],{},"The cable must additionally satisfy one of three conditions: an earthed electrical screen with armouring or a reinforced outer sheath; or a resistant outer sheath plus a continuous cover that protects against tools during excavation and overhangs on both sides; or installation in a duct or an equivalent system. Once one of these is satisfied, no additional measures are required for protection against electric shock.",[16,3111,3112,3113,3116],{},"For marking in the ground, ",[20,3114,3115],{},"point d"," carries its own rules: markers at the ends of straight sections, at least every two hundred metres, with a surface of at least 0.01 m² and a lightning symbol in relief. Connections of low-voltage network users are exempt.",[11,3118,3120],{"id":3119},"which-cable-is-allowed-in-which-installation-method","Which cable is allowed in which installation method?",[16,3122,3123],{},"The installation method restricts the choice of cable, independently of cross-section.",[53,3125,3126,3137],{},[56,3127,3128],{},[59,3129,3130,3132,3135],{},[62,3131,2386],{},[62,3133,3134],{},"Permitted",[62,3136,2905],{},[79,3138,3139,3151,3162,3173,3185,3197,3209],{},[59,3140,3141,3144,3147],{},[84,3142,3143],{},"buried",[84,3145,3146],{},"cables only",[84,3148,3149],{},[20,3150,870],{},[59,3152,3153,3156,3158],{},[84,3154,3155],{},"in free air and surface-mounted",[84,3157,3146],{},[84,3159,3160],{},[20,3161,179],{},[59,3163,3164,3167,3169],{},[84,3165,3166],{},"trough",[84,3168,3146],{},[84,3170,3171],{},[20,3172,245],{},[59,3174,3175,3178,3181],{},[84,3176,3177],{},"trunking",[84,3179,3180],{},"insulated conductors as well; outside electrical service rooms with solid walls and a lid that opens only with a tool",[84,3182,3183],{},[20,3184,245],{},[59,3186,3187,3190,3193],{},[84,3188,3189],{},"mouldings, skirtings, architraves",[84,3191,3192],{},"insulated conductors or single-core cables",[84,3194,3195],{},[20,3196,917],{},[59,3198,3199,3202,3205],{},[84,3200,3201],{},"conduits",[84,3203,3204],{},"insulated conductors or cables",[84,3206,3207],{},[20,3208,930],{},[59,3210,3211,3214,3217],{},[84,3212,3213],{},"structural voids",[84,3215,3216],{},"no conductors with basic insulation only",[84,3218,3219],{},[20,3220,294],{},[16,3222,3223,3224,3226,3227,3230,3231,3234,3235,3237,3238,3242,3243,3247],{},"On top of that comes the reaction-to-fire class. In ",[37,3225,3213],{}," and in ",[37,3228,3229],{},"mouldings, skirtings or architraves made of combustible materials",", ",[20,3232,3233],{},"sub-section 4.3.3.5 point b"," expressly requires the characteristic or class of ",[20,3236,960],{}," — that is, F2 or at least Cca. A timber-stud wall is a structural void. Which cable type suits which use is covered in ",[22,3239,3241],{"href":3240},"\u002Fen\u002Fblog\u002Fxvb-vs-vob-cable","XVB versus VOB","; for wet rooms the volume rules from ",[22,3244,3246],{"href":3245},"\u002Fen\u002Fblog\u002Fbathroom-cables-arei-zones","Bathroom cables and AREI zones"," apply on top.",[11,3249,3251],{"id":3250},"how-does-planelec-record-the-installation-method-and-what-appears-in-the-export","How does PlanElec record the installation method, and what appears in the export?",[16,3253,3254],{},"PlanElec knows twelve installation methods relevant to housing and stores the AREI reference each one sits under:",[53,3256,3257,3270],{},[56,3258,3259],{},[59,3260,3261,3264,3267],{},[62,3262,3263],{},"Choice in PlanElec",[62,3265,3266],{},"Short code",[62,3268,3269],{},"Stored AREI reference",[79,3271,3272,3282,3295,3306,3317,3328,3339,3350,3361,3372,3383,3394],{},[59,3273,3274,3276,3278],{},[84,3275,2478],{},[84,3277,1003],{},[84,3279,3280],{},[20,3281,1008],{},[59,3283,3284,3287,3289],{},[84,3285,3286],{},"surface-mounted conduit",[84,3288,1016],{},[84,3290,3291,1021,3293],{},[20,3292,1008],{},[20,3294,1024],{},[59,3296,3297,3300,3302],{},[84,3298,3299],{},"concealed in flexible conduit",[84,3301,1032],{},[84,3303,3304],{},[20,3305,1037],{},[59,3307,3308,3311,3313],{},[84,3309,3310],{},"concealed direct",[84,3312,1045],{},[84,3314,3315],{},[20,3316,1050],{},[59,3318,3319,3322,3324],{},[84,3320,3321],{},"in conduit",[84,3323,1058],{},[84,3325,3326],{},[20,3327,196],{},[59,3329,3330,3333,3335],{},[84,3331,3332],{},"bundle of conduits",[84,3334,1070],{},[84,3336,3337],{},[20,3338,196],{},[59,3340,3341,3344,3346],{},[84,3342,3343],{},"hollow wall \u002F wall panel",[84,3345,1082],{},[84,3347,3348],{},[20,3349,1087],{},[59,3351,3352,3355,3357],{},[84,3353,3354],{},"skirting \u002F cable trunking",[84,3356,1095],{},[84,3358,3359],{},[20,3360,1100],{},[59,3362,3363,3366,3368],{},[84,3364,3365],{},"underground",[84,3367,1108],{},[84,3369,3370],{},[20,3371,1113],{},[59,3373,3374,3377,3379],{},[84,3375,3376],{},"underground in cable conduit",[84,3378,1121],{},[84,3380,3381],{},[20,3382,1126],{},[59,3384,3385,3388,3390],{},[84,3386,3387],{},"cable tray \u002F ladder",[84,3389,1134],{},[84,3391,3392],{},[20,3393,1139],{},[59,3395,3396,3399,3401],{},[84,3397,3398],{},"free in ceiling or cavity",[84,3400,1147],{},[84,3402,3403],{},[20,3404,1152],{},[16,3406,3407,3408,3411],{},"The method is attached to the segment, not to the whole cable: a route on the floor plan can carry a different method per stretch, and each stretch is drawn in its own colour with the two-letter short code. On the single-line diagram, ",[37,3409,3410],{},"one"," governing method is drawn by default — the most restrictive of those present. Methods for which the tool holds no reliable reference table are deliberately given priority instead of being hidden behind an invented thermal ranking.",[16,3413,3414,3415,3418],{},"Since the update of 28 August 2026, cables in conduit, bundles of conduits, buried cables in a duct and surface conduits can be selected separately; each installation method carries the same complete sign with its own carrier line in the cable menu, the editor, the preview and the PDF. That carrier line is precisely what makes surface and concealed distinguishable: it represents the conductor, and which side the wall marks sit on ",[37,3416,3417],{},"is"," the statement. Since 29 August 2026 the installation method can be clicked directly in the diagram; the cable menu opens at the chosen spot and remains available in the properties panel. In the cable list it appears as its own column, \"Installation method\".",[11,3420,3422],{"id":3421},"what-the-arei-self-check-does-not-cover-here","What the AREI self-check does not cover here",[16,3424,3425],{},"The self-check is indicative. For the installation method that means, concretely:",[754,3427,3428,3438,3446,3457,3462],{},[757,3429,3430,3431,3434,3435,3437],{},"It does ",[37,3432,3433],{},"not"," check current-carrying capacity under the recorded installation method. What is checked is whether the cable cross-section matches the rated current of the protective device — that is the pairing from ",[20,3436,2808],{},", which ignores the installation method. Grouping, ambient temperature and insulation enter no check at all.",[757,3439,3430,3440,3442,3443,3445],{},[37,3441,3433],{}," check whether the installation zones of ",[20,3444,3084],{}," are respected, whether the plaster or concrete cover is thick enough, or whether a buried cable lies deep enough. Those are site dimensions, not model data.",[757,3447,3448,3449,3451,3452,1021,3454,3456],{},"It does check ",[37,3450,3410],{}," method-dependent rule: cables installed in structural voids must run in a conduit or reach at least class Cca (",[20,3453,2591],{},[20,3455,960],{},"). If the fire class is missing, PlanElec reports a data gap rather than an error; if it is below Cca with no conduit documented, it is an error.",[757,3458,3430,3459,3461],{},[37,3460,3433],{}," check whether the recorded installation method matches what was actually installed later. That is a visual finding on site.",[757,3463,3464,3465,3468,3469,3472,3473,971],{},"It replaces ",[37,3466,3467],{},"neither"," measurement ",[37,3470,3471],{},"nor"," inspection; the official assessment rests exclusively with an approved body. The full scope is listed in ",[22,3474,3476],{"href":3475},"\u002Fen\u002Fhelp\u002Fwhat-the-self-check-verifies","What the self-check verifies",[11,3478,3480],{"id":3479},"which-mistakes-show-up-at-inspection","Which mistakes show up at inspection?",[754,3482,3483,3494,3502,3511,3521,3530,3540,3548],{},[757,3484,3485,3488,3489,2588,3491,3493],{},[37,3486,3487],{},"Insulated conductors instead of cables, surface-mounted or in a trough."," Loose VOB cores visible on a wall or lying in a trough breach ",[20,3490,179],{},[20,3492,245],{}," respectively: only cables are admitted there.",[757,3495,3496,3499,3500,971],{},[37,3497,3498],{},"Chase outside the installation zones."," Diagonal runs and routes straight across the middle of a wall are the classic finding under ",[20,3501,3084],{},[757,3503,3504,3507,3508,44],{},[37,3505,3506],{},"Cover too thin."," Less than 0.4 cm of plaster over the cable, or less than 3 cm of concrete for embedded wiring (",[20,3509,3510],{},"5.2.9.10 points a and b",[757,3512,3513,3516,3517,3520],{},[37,3514,3515],{},"Connection inside the conduit."," Terminals and connectors within a conduit are forbidden (",[20,3518,3519],{},"5.2.9.3 point f","); connections in draw and junction boxes belong on a suitable terminal block.",[757,3522,3523,3526,3527,44],{},[37,3524,3525],{},"Conduit no longer drawable."," Tight bends or overfilled conduits breach the requirement that conductors can be drawn in and removed at any time (",[20,3528,3529],{},"5.2.9.3 point e",[757,3531,3532,3535,3536,1021,3538,44],{},[37,3533,3534],{},"Structural void with Eca instead of Cca and no conduit."," A frequent finding in timber frame and suspended ceilings (",[20,3537,2591],{},[20,3539,960],{},[757,3541,3542,3545,3546,44],{},[37,3543,3544],{},"Buried cable too shallow."," Less than 0.60 m without a continuous protective duct (",[20,3547,2427],{},[757,3549,3550,3553,3554,3556],{},[37,3551,3552],{},"Installation method missing from the diagram."," A single-line diagram carrying type, cross-section and conductor count but no installation method is incomplete (",[20,3555,2761],{},") — however cleanly the installation itself was executed.",[11,3558,3560],{"id":3559},"further-reading","Further reading",[754,3562,3563,3567,3571,3576,3580],{},[757,3564,3565],{},[22,3566,2821],{"href":2820},[757,3568,3569],{},[22,3570,2982],{"href":2981},[757,3572,3573],{},[22,3574,3575],{"href":3240},"XVB versus VOB: which cable for what",[757,3577,3578],{},[22,3579,2723],{"href":2722},[757,3581,3582],{},[22,3583,3585],{"href":3584},"\u002Fen\u002Fblog\u002Fsingle-line-diagram","Creating a single-line diagram step by step",[16,3587,3588],{},[22,3589,3591],{"href":3590},"\u002Fen","Open PlanElec and record your installation methods →",[16,3593,3594],{},[20,3595,3596],{},"Regulatory basis: AREI\u002FRGIE book 1 V06 — sections 2.6.1, 2.7.1, 2.7.2, 5.2.2, 5.2.8, sub-sections 3.1.2.1, 3.1.2.2, 3.1.2.3, 4.3.3.5, 4.4.1.4 with table 4.11, 5.2.1.2, 5.2.3.1, 5.2.7.2, 5.2.7.3 and section 5.2.9 with sub-sections 5.2.9.1 to 5.2.9.15. The official text, the actual condition of the installation and the judgement of the approved body remain decisive.",{"title":1342,"searchDepth":1343,"depth":1343,"links":3598},[3599,3600,3601,3602,3603,3604,3605,3606,3607,3608,3609,3610,3611],{"id":2340,"depth":1343,"text":2341},{"id":2689,"depth":1343,"text":2690},{"id":2727,"depth":1343,"text":2728},{"id":2824,"depth":1343,"text":2825},{"id":2886,"depth":1343,"text":2887},{"id":2986,"depth":1343,"text":2987},{"id":3003,"depth":1343,"text":3004},{"id":3095,"depth":1343,"text":3096},{"id":3119,"depth":1343,"text":3120},{"id":3250,"depth":1343,"text":3251},{"id":3421,"depth":1343,"text":3422},{"id":3479,"depth":1343,"text":3480},{"id":3559,"depth":1343,"text":3560},"The seventeen installation methods of sub-section 5.2.2.1, their specific rules in section 5.2.9, how they govern current-carrying capacity and where the entry is actually mandatory — with the AREI article next to every statement.","en",{},"\u002Fblog\u002Finstallation-methods-arei.en",{"title":2335,"description":3612},"blog\u002Finstallation-methods-arei.en",[1372,1373,3619,3620,3621,3622,3623,3624],"installation methods","single-line diagram","current-carrying capacity","cable installation","installation zones","Belgium","U-n7W9vh2ymcdPyPLaDwiRUpN3HWDKdtxIzl-lzken4",{"id":3627,"title":3628,"articleId":6,"body":3629,"category":1358,"date":1359,"description":4932,"extension":1361,"lastUpdated":1359,"locale":4933,"meta":4934,"navigation":1364,"path":4935,"publishDate":1359,"readTime":1366,"refreshInterval":1367,"seo":4936,"slug":4937,"stem":4938,"tags":4939,"__hash__":4946},"blog\u002Fblog\u002Finstallation-methods-arei.fr.md","Modes de pose selon le RGIE : quelle mention doit figurer au schéma unifilaire ?",{"type":8,"value":3630,"toc":4917},[3631,3635,3658,3665,3985,3992,3996,4009,4030,4034,4040,4104,4110,4128,4132,4135,4157,4171,4191,4195,4198,4274,4281,4289,4293,4303,4306,4310,4319,4329,4340,4360,4380,4398,4402,4412,4415,4422,4426,4429,4528,4555,4559,4562,4722,4729,4736,4740,4743,4794,4798,4874,4878,4906,4912],[11,3632,3634],{"id":3633},"quels-modes-de-pose-le-rgie-reconnaît-il-et-lequel-figure-au-schéma-unifilaire","Quels modes de pose le RGIE reconnaît-il — et lequel figure au schéma unifilaire ?",[16,3636,3637,3638,3640,3641,3643,3644,3647,3648,3651,3652,2362,3655,44],{},"Le RGIE énumère de manière limitative les modes de pose admis pour les canalisations basse tension : dix-sept lettres, de ",[20,3639,22],{}," à ",[20,3642,26],{},", à la ",[20,3645,3646],{},"sous-section 5.2.2.1.",", des lignes aériennes à la pose enterrée, en montage apparent, encastrée, sous plinthes et gouttières, jusqu’aux canalisations chauffantes dans les plafonds et planchers. Pour la plupart de ces modes, la ",[20,3649,3650],{},"section 5.2.9."," ajoute des règles propres et contraignantes. Et le mode retenu n’est pas une affaire interne à l’installateur : le schéma unifilaire d’une installation domestique doit reprendre, à côté du type, de la section et du nombre de conducteurs, ",[37,3653,3654],{},"le mode de pose des canalisations électriques",[20,3656,3657],{},"sous-section 3.1.2.2. point a.",[16,3659,3660,3661,3664],{},"La raison figure ailleurs dans le règlement. Le courant admissible IZ d’une canalisation est notamment fonction « du mode de pose et de l’environnement des canalisations électriques » (",[20,3662,3663],{},"sous-section 4.4.1.4.","). Sans le mode de pose, impossible donc de juger si une section convient au circuit — d’où sa présence au schéma.",[53,3666,3667,3686],{},[56,3668,3669],{},[59,3670,3671,3677,3680,3683],{},[62,3672,3673,3674,68],{},"Lettre (",[20,3675,3676],{},"5.2.2.1.",[62,3678,3679],{},"Mode de pose",[62,3681,3682],{},"Application courante en logement",[62,3684,3685],{},"Règles particulières",[79,3687,3688,3707,3723,3737,3751,3766,3782,3797,3813,3828,3844,3859,3874,3893,3909,3925,3940,3955,3970],{},[59,3689,3690,3692,3695,3698],{},[84,3691,22],{},[84,3693,3694],{},"lignes aériennes",[84,3696,3697],{},"alimentation d’une annexe",[84,3699,3700,3703,3704,68],{},[20,3701,3702],{},"5.2.9.1."," (renvoie au livre 3, ",[20,3705,3706],{},"chapitre 7.1.",[59,3708,3709,3711,3714,3717],{},[84,3710,105],{},[84,3712,3713],{},"enterrées directement",[84,3715,3716],{},"prise de jardin, carport",[84,3718,3719,3722],{},[20,3720,3721],{},"5.2.9.2. point a."," : 0,60 m de profondeur au minimum, câbles uniquement",[59,3724,3725,3727,3730,3733],{},[84,3726,122],{},[84,3728,3729],{},"enterrées avec protection mécanique",[84,3731,3732],{},"câble sous bande de protection",[84,3734,3735],{},[20,3736,3721],{},[59,3738,3739,3741,3744,3747],{},[84,3740,137],{},[84,3742,3743],{},"enterrées dans des fourreaux",[84,3745,3746],{},"traversée sous une allée ou une terrasse",[84,3748,3749],{},[20,3750,3721],{},[59,3752,3753,3755,3758,3761],{},[84,3754,152],{},[84,3756,3757],{},"lignes de contacts roulants ou glissants",[84,3759,3760],{},"sans objet en logement",[84,3762,3763],{},[20,3764,3765],{},"5.2.1.4. point a.",[59,3767,3768,3770,3773,3776],{},[84,3769,168],{},[84,3771,3772],{},"en montage apparent",[84,3774,3775],{},"XVB visible en cave, garage, local technique",[84,3777,3778,3781],{},[20,3779,3780],{},"5.2.9.5."," : câbles uniquement ; distance à la paroi ≤ 0,3 × diamètre extérieur",[59,3783,3784,3786,3789,3792],{},[84,3785,185],{},[84,3787,3788],{},"sous conduits encastrés",[84,3790,3791],{},"standard en construction neuve : VOB en préflex",[84,3793,3794],{},[20,3795,3796],{},"5.2.9.3.",[59,3798,3799,3801,3804,3807],{},[84,3800,201],{},[84,3802,3803],{},"sous moulures, plinthes et chambranles",[84,3805,3806],{},"rénovation, goulotte apparente",[84,3808,3809,3812],{},[20,3810,3811],{},"5.2.9.4."," : conducteurs isolés ou câbles unipolaires uniquement",[59,3814,3815,3817,3820,3823],{},[84,3816,218],{},[84,3818,3819],{},"à l’air libre avec attaches ou sur chemins de câbles, échelles, tablettes, corbeaux",[84,3821,3822],{},"local technique, chaufferie",[84,3824,3825,3827],{},[20,3826,3780],{}," : distance à toute paroi ≥ 0,3 × diamètre extérieur",[59,3829,3830,3832,3835,3838],{},[84,3831,234],{},[84,3833,3834],{},"sous goulottes et gouttières",[84,3836,3837],{},"tracé de distribution en local technique",[84,3839,3840,3843],{},[20,3841,3842],{},"5.2.9.6."," : dans les gouttières, câbles uniquement",[59,3845,3846,3848,3851,3854],{},[84,3847,251],{},[84,3849,3850],{},"dans des gaines",[84,3852,3853],{},"tracé au-dessus du sol",[84,3855,3856],{},[20,3857,3858],{},"5.2.9.7.",[59,3860,3861,3863,3866,3869],{},[84,3862,267],{},[84,3864,3865],{},"dans des caniveaux ouverts, fermés ou remplis de sable",[84,3867,3868],{},"caniveau de sol, application industrielle",[84,3870,3871],{},[20,3872,3873],{},"5.2.9.8.",[59,3875,3876,3878,3881,3884],{},[84,3877,283],{},[84,3879,3880],{},"dans les vides de construction, alvéoles et blocs manufacturés",[84,3882,3883],{},"blocs creux, faux plafond",[84,3885,3886,3889,3890],{},[20,3887,3888],{},"5.2.9.9."," et ",[20,3891,3892],{},"4.3.3.5. point b.",[59,3894,3895,3897,3900,3903],{},[84,3896,303],{},[84,3898,3899],{},"dans les huisseries",[84,3901,3902],{},"cloison sèche, ossature bois",[84,3904,3905,3889,3907],{},[20,3906,3888],{},[20,3908,3892],{},[59,3910,3911,3913,3916,3919],{},[84,3912,320],{},[84,3914,3915],{},"en encastrements directs, sans conduits",[84,3917,3918],{},"XVB directement dans la saignée",[84,3920,3921,3924],{},[20,3922,3923],{},"5.2.9.10."," : gabarit, béton ≥ 3 cm, enduit ≥ 0,4 cm",[59,3926,3927,3929,3932,3935],{},[84,3928,337],{},[84,3930,3931],{},"dans les canalisations préfabriquées",[84,3933,3934],{},"rare en logement",[84,3936,3937],{},[20,3938,3939],{},"5.2.9.11.",[59,3941,3942,3944,3947,3950],{},[84,3943,353],{},[84,3945,3946],{},"sur des isolateurs",[84,3948,3949],{},"installations anciennes",[84,3951,3952],{},[20,3953,3954],{},"5.2.9.12.",[59,3956,3957,3959,3962,3965],{},[84,3958,16],{},[84,3960,3961],{},"par immersion dans l’eau",[84,3963,3964],{},"technique de piscine",[84,3966,3967],{},[20,3968,3969],{},"5.2.2.1. point p.",[59,3971,3972,3974,3977,3980],{},[84,3973,26],{},[84,3975,3976],{},"dans les plafonds, planchers et murs pour canalisations et panneaux chauffants",[84,3978,3979],{},"chauffage par le sol, trames chauffantes",[84,3981,3982],{},[20,3983,3984],{},"5.2.9.13.",[16,3986,3987,3988,3991],{},"D’autres modes de pose ne sont pas interdits, mais ils relèvent de la clause résiduelle : ils répondent « aux règles de l’art en la matière » (",[20,3989,3990],{},"sous-section 5.2.2.4.","). Travailler hors de la liste, c’est donc quitter le domaine pour lequel le RGIE formule lui-même une règle.",[11,3993,3995],{"id":3994},"quelle-est-la-différence-entre-le-point-e-et-le-point-m","Quelle est la différence entre le point e et le point m ?",[16,3997,3998,3999,4001,4002,4004,4005,4008],{},"C’est la confusion la plus fréquente, car dans le langage courant les deux s’appellent « encastré ». La différence est le conduit. Le point ",[20,4000,185],{}," s’intitule littéralement « sous conduits encastrés » — le texte néerlandais dit « in verzonken buizen ». Le point ",[20,4003,320],{}," s’intitule au contraire « en encastrements directs, ",[37,4006,4007],{},"sans"," conduits ».",[16,4010,4011,4012,4014,4015,4018,4019,4014,4021,4024,4025,4029],{},"Ce n’est pas une nuance de vocabulaire mais la frontière entre deux corps de règles. Pour ",[20,4013,185],{},", c’est la ",[20,4016,4017],{},"sous-section 5.2.9.3."," qui s’applique, avec les règles des conduits : rayons de courbure, conducteurs toujours enfilables et retirables, pas de connexion dans le conduit. Pour ",[20,4020,320],{},[20,4022,4023],{},"sous-section 5.2.9.10."," avec le gabarit et les recouvrements minimaux. Le choix du matériel dans chaque cas et son coût sont comparés dans ",[22,4026,4028],{"href":4027},"\u002Ffr\u002Fblog\u002Fpreflex-vs-pose-libre","préflex ou pose libre"," ; le présent article décrit la systématique dans laquelle ces deux variantes se situent.",[11,4031,4033],{"id":4032},"pourquoi-le-mode-de-pose-détermine-t-il-le-courant-admissible","Pourquoi le mode de pose détermine-t-il le courant admissible ?",[16,4035,4036,4037,4039],{},"La ",[20,4038,3663],{}," énumère cinq grandeurs dont dépend IZ. Le mode de pose en est une, et c’est la seule qui ne se lit pas sur le câble lui-même.",[53,4041,4042,4055],{},[56,4043,4044],{},[59,4045,4046,4052],{},[62,4047,4048,4049],{},"Grandeur selon ",[20,4050,4051],{},"4.4.1.4.",[62,4053,4054],{},"Ce qu’elle signifie sur le plan",[79,4056,4057,4068,4076,4084,4093],{},[59,4058,4059,4062],{},[84,4060,4061],{},"section des conducteurs",[84,4063,4064,4065,68],{},"mention au schéma unifilaire (",[20,4066,4067],{},"3.1.2.2. point a.",[59,4069,4070,4073],{},[84,4071,4072],{},"isolation des conducteurs",[84,4074,4075],{},"type de câble, par exemple XVB ou VOB",[59,4077,4078,4081],{},[84,4079,4080],{},"constitution de la canalisation électrique",[84,4082,4083],{},"unipolaire ou multipolaire, armure, écran",[59,4085,4086,4089],{},[84,4087,4088],{},"mode de pose et environnement",[84,4090,4064,4091,68],{},[20,4092,4067],{},[59,4094,4095,4098],{},[84,4096,4097],{},"température ambiante",[84,4099,4100,4101],{},"emplacement de la canalisation, voir ",[20,4102,4103],{},"5.2.3.1.",[16,4105,4106,4107,4109],{},"Le calcul proprement dit ne figure pas dans le RGIE. Le texte se borne à dire que le courant admissible « est calculé conformément aux règles de l’art » (",[20,4108,4051],{},") et que les ministres compétents peuvent en fixer les modalités. En pratique, les tableaux et les facteurs de correction viennent donc de la série de normes NBN HD 60364-5-52, et non du RGIE.",[16,4111,4112,4113,4116,4117,4119,4120,4123,4124,971],{},"Ce que le RGIE fixe, en revanche, est souvent confondu avec cela : le ",[20,4114,4115],{},"tableau 4.11."," donne, pour les installations domestiques, l’intensité nominale ",[37,4118,528],{}," par section, séparément pour le coupe-circuit à fusible et pour le disjoncteur : pour 1,5 mm² 10 A et 16 A, pour 2,5 mm² 16 A et 20 A, pour 4 mm² 20 A et 25 A, pour 6 mm² 32 A et 40 A, pour 10 mm² 50 A et 63 A. Ce tableau ignore le mode de pose. C’est un plafond, pas une autorisation : la condition IZ ≥ IB de la ",[20,4121,4122],{},"sous-section 5.2.1.2. point a."," doit être satisfaite en plus. La correspondance section-protection est développée dans ",[22,4125,4127],{"href":4126},"\u002Ffr\u002Fblog\u002Fsection-cable-disjoncteur","section de câble et disjoncteur",[11,4129,4131],{"id":4130},"que-font-le-groupement-la-température-ambiante-et-lisolant-thermique-au-courant-admissible","Que font le groupement, la température ambiante et l’isolant thermique au courant admissible ?",[16,4133,4134],{},"Les trois abaissent IZ, et dans les trois cas le RGIE fournit la condition, pas le facteur.",[16,4136,4137,4140,4141,4144,4145,4148,4149,4152,4153,4156],{},[37,4138,4139],{},"Groupement."," Le RGIE fixe la limite avec précision : un câble ou conducteur isolé est ",[37,4142,4143],{},"installé séparément"," lorsqu’il se trouve à une distance supérieure ou égale à 20 mm de tout autre câble ou conducteur isolé (",[20,4146,4147],{},"section 2.7.1.","). En deçà, il est posé « en faisceaux ou en nappe ». Cette distinction a une conséquence directe dans le RGIE — mais pour la propagation du feu, pas pour l’échauffement : posés séparément, les conducteurs et câbles ont au moins la caractéristique F1 ou la classe Eca (",[20,4150,4151],{},"sous-section 5.2.7.2.",") ; en faisceaux ou en nappe, au moins F2 ou la classe Cca (",[20,4154,4155],{},"sous-section 5.2.7.3.","), et ce « indépendamment de la distance sur laquelle » ils sont effectivement groupés. Le facteur thermique de groupement, lui, relève à nouveau des règles de l’art.",[16,4158,4159,4162,4163,4166,4167,4170],{},[37,4160,4161],{},"Température ambiante."," La ",[20,4164,4165],{},"sous-section 5.2.3.1."," exige que les canalisations conviennent à la température ambiante locale la plus basse comme la plus élevée et ne soient posées que dans la plage de température indiquée par le fabricant. S’y ajoute la ",[20,4168,4169],{},"section 5.2.8."," : les canalisations ne peuvent être soumises à des températures nuisibles au voisinage de conduites de chauffage, d’air chaud ou de fumée, et doivent en être suffisamment éloignées ou séparées par un écran thermique. Poser une canalisation le long du collecteur de chauffage, c’est modifier son environnement thermique — lequel relève de la même mention que le mode de pose.",[16,4172,4173,4176,4177,4180,4181,4183,4184,4187,4188,4190],{},[37,4174,4175],{},"Isolant thermique."," Ici, une constatation honnête s’impose : le RGIE ne contient ",[37,4178,4179],{},"aucun"," facteur de réduction propre aux canalisations posées dans ou sous un isolant thermique. L’« isolation thermique » y apparaît comme précaution pour les températures inférieures à −25 °C (",[20,4182,4103],{},") et au chapitre des panneaux chauffants, où le matériau isolant en contact avec l’installation de chauffage doit être incombustible (",[20,4185,4186],{},"5.2.9.13. point b.5.","). Une canalisation posée dans une toiture inclinée isolée relève donc du « mode de pose et environnement » de ",[20,4189,4051],{}," et s’apprécie selon les règles de l’art — pas selon un tableau RGIE qui n’existe pas.",[11,4192,4194],{"id":4193},"où-la-mention-doit-elle-figurer-schéma-unifilaire-plan-de-position-ou-liste-de-matériel","Où la mention doit-elle figurer : schéma unifilaire, plan de position ou liste de matériel ?",[16,4196,4197],{},"Ces trois documents ont dans le RGIE des contenus obligatoires nettement distincts.",[53,4199,4200,4212],{},[56,4201,4202],{},[59,4203,4204,4206,4209],{},[62,4205,2899],{},[62,4207,4208],{},"Mode de pose exigé ?",[62,4210,4211],{},"Référence",[79,4213,4214,4229,4245,4260],{},[59,4215,4216,4219,4225],{},[84,4217,4218],{},"schéma unifilaire (domestique)",[84,4220,4221,4224],{},[37,4222,4223],{},"oui",", explicitement",[84,4226,4227],{},[20,4228,4067],{},[59,4230,4231,4234,4240],{},[84,4232,4233],{},"plan de position (domestique)",[84,4235,4236,4237,4239],{},"non — il indique la ",[37,4238,2933],{}," des éléments",[84,4241,4242],{},[20,4243,4244],{},"3.1.2.3. point a.",[59,4246,4247,4250,4255],{},[84,4248,4249],{},"schéma de circuits (non domestique)",[84,4251,4252,4254],{},[37,4253,4223],{},", avec la longueur et le nombre de conducteurs",[84,4256,4257],{},[20,4258,4259],{},"3.1.2.2. point b.",[59,4261,4262,4265,4268],{},[84,4263,4264],{},"liste de matériel",[84,4266,4267],{},"non prescrite",[84,4269,4270,4271],{},"admise comme annexe au titre de ",[20,4272,4273],{},"3.1.2.1. point c.",[16,4275,4276,4277,4280],{},"La liste de matériel n’est pas un document obligatoire au sens du RGIE. La ",[20,4278,4279],{},"sous-section 3.1.2.1. point c."," permet seulement de compléter schémas et plans par des documents « précisant les différentes caractéristiques du matériel électrique et\u002Fou des produits ». Une liste de câbles reprenant le mode de pose par canalisation est exactement cela : utile pour le métré et l’exécution, mais elle ne dispense pas de porter la mention au schéma unifilaire lui-même.",[16,4282,4283,4284,4288],{},"La répartition entre schéma et plan de position est détaillée dans ",[22,4285,4287],{"href":4286},"\u002Ffr\u002Fblog\u002Fcheminements-et-longueurs-de-cables","cheminements et longueurs de câbles"," ; on y lit aussi pourquoi la longueur n’est obligatoire que dans le schéma de circuits non domestique.",[11,4290,4292],{"id":4291},"quand-le-mode-de-pose-change-t-il-à-lintérieur-dune-même-canalisation","Quand le mode de pose change-t-il à l’intérieur d’une même canalisation ?",[16,4294,4295,4296,4299,4300,44],{},"Une canalisation n’a que rarement un seul mode de pose. Du tableau à travers le mur, sur le plafond, puis en terre et enfin contre une façade : cela en fait quatre. Le RGIE dispose d’une notion pour ce cas. On entend par ",[37,4297,4298],{},"origine du circuit"," l’origine de la canalisation électrique, « soit l’endroit où change la section, la nature ou la constitution de la canalisation électrique ainsi que son mode de pose » (",[20,4301,4302],{},"section 2.6.1.",[16,4304,4305],{},"Concrètement : chaque changement de mode de pose ouvre un tronçon d’étude distinct. Pour le dimensionnement, c’est le plus défavorable qui compte — une canalisation qui traverse deux mètres de faisceau de conduits avant de courir librement dans le plafond ne se dimensionne pas sur la partie libre. Pour le schéma : tous les modes rencontrés doivent être documentés, pas seulement le plus long.",[11,4307,4309],{"id":4308},"quelles-règles-sappliquent-aux-canalisations-encastrées","Quelles règles s’appliquent aux canalisations encastrées ?",[16,4311,4312,4313,4315,4316,4318],{},"Pour l’encastrement direct sans conduit (",[20,4314,3010],{},"), la ",[20,4317,4023],{}," est la disposition de référence, et elle est inhabituellement concrète.",[16,4320,4321,4322,4325,4326,44],{},"Les canalisations noyées dans le ",[37,4323,4324],{},"béton ou le ciment"," sont couvertes d’une couche d’au moins 3 cm ; les conducteurs pourvus de la seule isolation principale ne peuvent pas y être noyés (",[20,4327,4328],{},"point a.",[16,4330,4331,4332,4335,4336,4339],{},"Les canalisations encastrées sans conduit ",[37,4333,4334],{},"dans les murs des locaux"," doivent en outre rester dans le gabarit (",[20,4337,4338],{},"point b.",") :",[754,4341,4342,4345,4348,4351,4354,4357],{},[757,4343,4344],{},"le parcours ne comporte que des tracés horizontaux et verticaux, les tracés horizontaux dans un plafond étant perpendiculaires aux parois verticales ;",[757,4346,4347],{},"les parcours horizontaux se trouvent entre 25 et 35 cm du plancher ou du plafond, et également entre 25 et 35 cm au-dessus de la face inférieure du linteau des fenêtres, pour autant qu’ils demeurent alors à 25 cm au moins sous le plafond ;",[757,4349,4350],{},"les parcours verticaux se trouvent le plus près possible d’un angle du local ou entre 10 et 20 cm des chambranles ou huisseries des portes ;",[757,4352,4353],{},"hors de ce gabarit, seule la pose à la verticale d’une machine ou d’un appareil visible est admise ;",[757,4355,4356],{},"les canalisations ne sont soumises à aucune contrainte mécanique, ni lors de la pose ni ultérieurement, et sont fixées sans détérioration aux parois ;",[757,4358,4359],{},"l’épaisseur de l’enduit de revêtement n’est pas inférieure à 0,4 cm.",[16,4361,4362,4363,4365,4366,4369,4370,4373,4374,4377,4378,44],{},"Pour les conduits, c’est la ",[20,4364,4017],{}," qui prend le relais : les conducteurs ou câbles doivent pouvoir être enfilés et retirés à tout moment (",[20,4367,4368],{},"point e.","), les connexions dans le conduit sont interdites (",[20,4371,4372],{},"point f.","), et dans les conduits encastrés les tés et coudes sont proscrits tandis que les conducteurs restent accessibles dans les boîtes de jonction, de dérivation et de tirage (",[20,4375,4376],{},"point i.2.","). Les conduits en matériau combustible ne sont admis que noyés à 3 cm au moins dans des matériaux incombustibles (",[20,4379,4372],{},[16,4381,4382,4383,4386,4387,4390,4391,4394,4395,4397],{},"Une exception importante : pour les ",[37,4384,4385],{},"installations à très basse tension",", le gabarit de ",[20,4388,4389],{},"5.2.9.10. point b."," ne s’applique explicitement pas (",[20,4392,4393],{},"sous-section 5.2.9.15. point b.","). Les lignes de bus, de sonnerie et de commande en TBT ne doivent donc pas suivre le gabarit — les autres règles de la ",[20,4396,3650],{}," restent d’application.",[11,4399,4401],{"id":4400},"que-prévoit-le-rgie-pour-les-canalisations-enterrées","Que prévoit le RGIE pour les canalisations enterrées ?",[16,4403,4036,4404,4407,4408,4411],{},[20,4405,4406],{},"sous-section 5.2.9.2. point a."," est l’une des dispositions les plus nettes du chapitre. Dans le sol et dans les fourreaux souterrains inaccessibles, seuls des ",[37,4409,4410],{},"câbles"," peuvent être posés, à l’exception des conducteurs de protection indépendants. La profondeur minimale est de 0,60 m mesurée à partir de la surface du sol, « sauf impossibilité technique ». Si cette profondeur ne peut être atteinte, la protection est assurée par un fourreau continu ou à joints étanches en matériau durable et résistant.",[16,4413,4414],{},"Le câble doit en outre remplir l’une de trois conditions : écran électrique mis à la terre avec armure ou gaine extérieure renforcée ; ou gaine extérieure résistante complétée par une couverture continue qui protège des outils lors de travaux de fouille et déborde des deux côtés ; ou pose dans un fourreau ou un système équivalent. L’une de ces conditions remplie, aucune mesure supplémentaire n’est requise pour la protection contre les chocs électriques.",[16,4416,4417,4418,4421],{},"Pour la signalisation dans le sol, le ",[20,4419,4420],{},"point d."," contient ses propres règles : repères aux extrémités des tronçons rectilignes, au moins tous les deux cents mètres, d’une surface d’au moins 0,01 m² et portant un éclair en relief. Les branchements des utilisateurs du réseau basse tension en sont dispensés.",[11,4423,4425],{"id":4424},"quel-câble-pour-quel-mode-de-pose","Quel câble pour quel mode de pose ?",[16,4427,4428],{},"Le mode de pose restreint le choix du câble, indépendamment de la section.",[53,4430,4431,4442],{},[56,4432,4433],{},[59,4434,4435,4437,4440],{},[62,4436,3679],{},[62,4438,4439],{},"Admis",[62,4441,4211],{},[79,4443,4444,4457,4468,4479,4491,4504,4516],{},[59,4445,4446,4449,4452],{},[84,4447,4448],{},"enterré",[84,4450,4451],{},"câbles uniquement",[84,4453,4454],{},[20,4455,4456],{},"5.2.9.2. a.",[59,4458,4459,4462,4464],{},[84,4460,4461],{},"à l’air libre et en montage apparent",[84,4463,4451],{},[84,4465,4466],{},[20,4467,3780],{},[59,4469,4470,4473,4475],{},[84,4471,4472],{},"gouttière",[84,4474,4451],{},[84,4476,4477],{},[20,4478,3842],{},[59,4480,4481,4484,4487],{},[84,4482,4483],{},"goulotte",[84,4485,4486],{},"également conducteurs isolés ; hors des locaux du service électrique, à parois pleines et couvercle ouvrable à l’outil",[84,4488,4489],{},[20,4490,3842],{},[59,4492,4493,4496,4499],{},[84,4494,4495],{},"moulures, plinthes et chambranles",[84,4497,4498],{},"conducteurs isolés ou câbles unipolaires",[84,4500,4501],{},[20,4502,4503],{},"5.2.9.4. b.",[59,4505,4506,4508,4511],{},[84,4507,3201],{},[84,4509,4510],{},"conducteurs isolés ou câbles",[84,4512,4513],{},[20,4514,4515],{},"5.2.9.3. b.",[59,4517,4518,4521,4524],{},[84,4519,4520],{},"vides de construction",[84,4522,4523],{},"pas de conducteurs pourvus de la seule isolation principale",[84,4525,4526],{},[20,4527,3888],{},[16,4529,4530,4531,4533,4534,4537,4538,4541,4542,4545,4546,4550,4551,971],{},"S’y ajoute la classe de réaction au feu. Dans les ",[37,4532,4520],{}," ainsi que dans les ",[37,4535,4536],{},"moulures, plinthes ou chambranles en matériaux combustibles",", la ",[20,4539,4540],{},"sous-section 4.3.3.5. point b."," exige explicitement la caractéristique ou la classe de ",[20,4543,4544],{},"5.2.7.3."," — donc F2 ou au moins Cca. Une cloison à ossature bois est un vide de construction. Le type de câble adapté à chaque usage est traité dans ",[22,4547,4549],{"href":4548},"\u002Ffr\u002Fblog\u002Fcable-xvb-vs-vob","XVB ou VOB"," ; pour les locaux humides s’ajoutent les règles de volumes de ",[22,4552,4554],{"href":4553},"\u002Ffr\u002Fblog\u002Fcables-salle-de-bain-rgie","câbles de salle de bain et volumes RGIE",[11,4556,4558],{"id":4557},"comment-planelec-enregistre-t-il-le-mode-de-pose-et-que-montre-lexport","Comment PlanElec enregistre-t-il le mode de pose, et que montre l’export ?",[16,4560,4561],{},"PlanElec connaît douze modes de pose pertinents pour le logement et conserve pour chacun la référence RGIE dont il relève :",[53,4563,4564,4577],{},[56,4565,4566],{},[59,4567,4568,4571,4574],{},[62,4569,4570],{},"Choix dans PlanElec",[62,4572,4573],{},"Code court",[62,4575,4576],{},"Référence RGIE enregistrée",[79,4578,4579,4591,4605,4617,4629,4640,4651,4663,4675,4686,4698,4710],{},[59,4580,4581,4584,4586],{},[84,4582,4583],{},"en saillie",[84,4585,1003],{},[84,4587,4588],{},[20,4589,4590],{},"5.2.2.1. d",[59,4592,4593,4596,4598],{},[84,4594,4595],{},"conduit apparent sur paroi",[84,4597,1016],{},[84,4599,4600,1021,4602],{},[20,4601,4590],{},[20,4603,4604],{},"5.2.9.3. h",[59,4606,4607,4610,4612],{},[84,4608,4609],{},"encastré dans gaine flexible",[84,4611,1032],{},[84,4613,4614],{},[20,4615,4616],{},"5.2.2.1. e",[59,4618,4619,4622,4624],{},[84,4620,4621],{},"encastré direct",[84,4623,1045],{},[84,4625,4626],{},[20,4627,4628],{},"5.2.2.1. m",[59,4630,4631,4634,4636],{},[84,4632,4633],{},"sous conduit",[84,4635,1058],{},[84,4637,4638],{},[20,4639,3796],{},[59,4641,4642,4645,4647],{},[84,4643,4644],{},"faisceau de conduits",[84,4646,1070],{},[84,4648,4649],{},[20,4650,3796],{},[59,4652,4653,4656,4658],{},[84,4654,4655],{},"cloison creuse \u002F panneau mural",[84,4657,1082],{},[84,4659,4660],{},[20,4661,4662],{},"5.2.2.1. k + l",[59,4664,4665,4668,4670],{},[84,4666,4667],{},"plinthe \u002F goulotte",[84,4669,1095],{},[84,4671,4672],{},[20,4673,4674],{},"5.2.2.1. f",[59,4676,4677,4679,4681],{},[84,4678,4448],{},[84,4680,1108],{},[84,4682,4683],{},[20,4684,4685],{},"5.2.2.1. b.1 + b.2",[59,4687,4688,4691,4693],{},[84,4689,4690],{},"enterré dans un fourreau",[84,4692,1121],{},[84,4694,4695],{},[20,4696,4697],{},"5.2.2.1. b.3",[59,4699,4700,4703,4705],{},[84,4701,4702],{},"chemin de câbles",[84,4704,1134],{},[84,4706,4707],{},[20,4708,4709],{},"5.2.2.1. g + h",[59,4711,4712,4715,4717],{},[84,4713,4714],{},"libre en plafond ou creux",[84,4716,1147],{},[84,4718,4719],{},[20,4720,4721],{},"5.2.2.1. g",[16,4723,4724,4725,4728],{},"Le mode de pose est attaché au tronçon, pas au câble entier : un cheminement sur le plan peut changer de mode d’un tronçon à l’autre, et chaque tronçon reçoit sa propre couleur avec le code de deux lettres. Au schéma unifilaire, ",[37,4726,4727],{},"un seul"," mode déterminant est tracé par défaut — le plus restrictif de ceux rencontrés. Les modes pour lesquels l’outil ne dispose d’aucune table de référence fiable reçoivent délibérément la priorité, plutôt que d’être masqués derrière un classement thermique inventé.",[16,4730,4731,4732,4735],{},"Depuis la mise à jour du 28 août 2026, les canalisations sous conduit, les faisceaux de conduits, les canalisations enterrées sous fourreau et les conduits apparents se choisissent séparément ; chaque mode de pose porte, dans le menu câble, l’éditeur, l’aperçu et le PDF, le même signe complet avec sa propre ligne support. Cette ligne support est précisément ce qui permet de distinguer l’apparent de l’encastré : elle représente le conducteur, et le côté où se trouvent les signes de paroi ",[37,4733,4734],{},"est"," l’information. Depuis le 29 août 2026, le mode de pose se clique directement dans le schéma ; le menu câble apparaît à l’endroit choisi et reste accessible dans le panneau des propriétés. Dans la liste de câbles, il apparaît en colonne propre « Mode de pose ».",[11,4737,4739],{"id":4738},"ce-que-lautocontrôle-rgie-ne-fait-pas-sur-ce-point","Ce que l’autocontrôle RGIE ne fait pas sur ce point",[16,4741,4742],{},"L’autocontrôle est indicatif. Pour le mode de pose, cela signifie concrètement :",[754,4744,4745,4755,4763,4775,4780],{},[757,4746,4747,4748,4751,4752,4754],{},"Il ne vérifie ",[37,4749,4750],{},"pas"," le courant admissible sous le mode de pose encodé. Ce qui est vérifié, c’est la correspondance entre la section du câble et l’intensité nominale de la protection — c’est-à-dire le ",[20,4753,4115],{},", qui ignore le mode de pose. Le groupement, la température ambiante et l’isolant n’entrent dans aucun contrôle.",[757,4756,4747,4757,4759,4760,4762],{},[37,4758,4750],{}," le respect du gabarit de ",[20,4761,4389],{},", l’épaisseur de l’enduit ou du béton, ni la profondeur d’une canalisation enterrée. Ce sont des cotes sur chantier, pas des données du modèle.",[757,4764,4765,4766,4769,4770,1021,4772,4774],{},"Il vérifie ",[37,4767,4768],{},"une"," règle dépendante du mode de pose : les câbles posés dans les vides de construction doivent être sous conduit ou atteindre au moins la classe Cca (",[20,4771,3892],{},[20,4773,4544],{},"). Si la classe de réaction au feu manque, PlanElec signale une donnée absente et non une erreur ; si elle est inférieure à Cca sans conduit documenté, c’est une erreur.",[757,4776,4747,4777,4779],{},[37,4778,4750],{}," si le mode de pose encodé correspond à ce qui a réellement été posé ensuite. C’est un constat visuel sur place.",[757,4781,4782,4783,4786,4787,4789,4790,971],{},"Il ne remplace ",[37,4784,4785],{},"ni"," mesure ",[37,4788,4785],{}," contrôle ; l’appréciation officielle relève exclusivement d’un organisme agréé. L’étendue complète est décrite dans ",[22,4791,4793],{"href":4792},"\u002Ffr\u002Fhelp\u002Fce-que-verifie-l-autocontrole","ce que vérifie l’autocontrôle",[11,4795,4797],{"id":4796},"quelles-erreurs-ressortent-au-contrôle","Quelles erreurs ressortent au contrôle ?",[754,4799,4800,4811,4819,4828,4838,4847,4857,4865],{},[757,4801,4802,4805,4806,3889,4808,4810],{},[37,4803,4804],{},"Conducteurs isolés au lieu de câbles en apparent ou en gouttière."," Des conducteurs VOB visibles contre le mur ou posés dans une gouttière contreviennent à ",[20,4807,3780],{},[20,4809,3842],{}," : seuls les câbles y sont admis.",[757,4812,4813,4816,4817],{},[37,4814,4815],{},"Saignée hors gabarit."," Tracés en diagonale et parcours au milieu de la paroi : le classique de ",[20,4818,4389],{},[757,4820,4821,4824,4825,44],{},[37,4822,4823],{},"Recouvrement insuffisant."," Moins de 0,4 cm d’enduit au-dessus de la canalisation ou moins de 3 cm de béton pour les canalisations noyées (",[20,4826,4827],{},"5.2.9.10. points a. et b.",[757,4829,4830,4833,4834,4837],{},[37,4831,4832],{},"Connexion dans le conduit."," Bornes et connecteurs à l’intérieur d’un conduit sont interdits (",[20,4835,4836],{},"5.2.9.3. point f.",") ; les raccordements dans les boîtes de tirage et de jonction se font sur un bornier approprié.",[757,4839,4840,4843,4844,44],{},[37,4841,4842],{},"Conduit devenu inutilisable."," Coudes trop serrés ou conduits surchargés violent l’exigence de pouvoir enfiler et retirer les conducteurs à tout moment (",[20,4845,4846],{},"5.2.9.3. point e.",[757,4848,4849,4852,4853,1021,4855,44],{},[37,4850,4851],{},"Vide de construction en Eca au lieu de Cca et sans conduit."," Constat fréquent en ossature bois et en faux plafond (",[20,4854,3892],{},[20,4856,4544],{},[757,4858,4859,4862,4863,44],{},[37,4860,4861],{},"Câble enterré trop peu profond."," Moins de 0,60 m sans fourreau continu (",[20,4864,3721],{},[757,4866,4867,4870,4871,4873],{},[37,4868,4869],{},"Mode de pose absent du schéma."," Un schéma unifilaire reprenant type, section et nombre de conducteurs mais pas le mode de pose est incomplet (",[20,4872,4067],{},") — quelle que soit la qualité d’exécution de l’installation.",[11,4875,4877],{"id":4876},"pour-aller-plus-loin","Pour aller plus loin",[754,4879,4880,4885,4890,4895,4900],{},[757,4881,4882],{},[22,4883,4884],{"href":4126},"Section de câble et disjoncteur",[757,4886,4887],{},[22,4888,4889],{"href":4286},"Cheminements et longueurs de câbles",[757,4891,4892],{},[22,4893,4894],{"href":4548},"XVB ou VOB : quel câble pour quel usage",[757,4896,4897],{},[22,4898,4899],{"href":4027},"Préflex ou pose libre",[757,4901,4902],{},[22,4903,4905],{"href":4904},"\u002Ffr\u002Fblog\u002Fschema-unifilaire","Réaliser un schéma unifilaire pas à pas",[16,4907,4908],{},[22,4909,4911],{"href":4910},"\u002Ffr","Ouvrir PlanElec et encoder les modes de pose →",[16,4913,4914],{},[20,4915,4916],{},"Base réglementaire : RGIE\u002FAREI livre 1 V06 — sections 2.6.1., 2.7.1., 2.7.2., 5.2.2., 5.2.8., sous-sections 3.1.2.1., 3.1.2.2., 3.1.2.3., 4.3.3.5., 4.4.1.4. avec le tableau 4.11., 5.2.1.2., 5.2.3.1., 5.2.7.2., 5.2.7.3. et section 5.2.9. avec les sous-sections 5.2.9.1. à 5.2.9.15. Le texte officiel, l’état réel de l’installation et le jugement de l’organisme agréé restent déterminants.",{"title":1342,"searchDepth":1343,"depth":1343,"links":4918},[4919,4920,4921,4922,4923,4924,4925,4926,4927,4928,4929,4930,4931],{"id":3633,"depth":1343,"text":3634},{"id":3994,"depth":1343,"text":3995},{"id":4032,"depth":1343,"text":4033},{"id":4130,"depth":1343,"text":4131},{"id":4193,"depth":1343,"text":4194},{"id":4291,"depth":1343,"text":4292},{"id":4308,"depth":1343,"text":4309},{"id":4400,"depth":1343,"text":4401},{"id":4424,"depth":1343,"text":4425},{"id":4557,"depth":1343,"text":4558},{"id":4738,"depth":1343,"text":4739},{"id":4796,"depth":1343,"text":4797},{"id":4876,"depth":1343,"text":4877},"Les dix-sept modes de pose de la sous-section 5.2.2.1, leurs règles particulières à la section 5.2.9, leur influence sur le courant admissible et l’endroit où la mention est obligatoire — avec la référence RGIE en regard de chaque affirmation.","fr",{},"\u002Fblog\u002Finstallation-methods-arei.fr",{"title":3628,"description":4932},"modes-de-pose-rgie","blog\u002Finstallation-methods-arei.fr",[1373,1372,4940,4941,4942,4943,4944,4945],"modes de pose","schéma unifilaire","courant admissible","pose de câbles","gabarit de pose","Belgique","XnO16CX903WzGSzKEl5cZqrc7hoXgXXKGSlWAjrxeic",{"id":4948,"title":4949,"articleId":6,"body":4950,"category":1358,"date":1359,"description":6214,"extension":1361,"lastUpdated":1359,"locale":6215,"meta":6216,"navigation":1364,"path":6217,"publishDate":1359,"readTime":1366,"refreshInterval":1367,"seo":6218,"slug":6219,"stem":6220,"tags":6221,"__hash__":6228},"blog\u002Fblog\u002Finstallation-methods-arei.nl.md","Plaatsingswijzen volgens het AREI: welke vermelding hoort in het eendraadschema?",{"type":8,"value":4951,"toc":6199},[4952,4956,4979,4986,5292,5299,5303,5316,5337,5341,5347,5409,5415,5433,5437,5440,5462,5475,5495,5499,5502,5578,5585,5593,5597,5607,5610,5614,5624,5633,5643,5663,5683,5701,5705,5715,5718,5725,5729,5732,5828,5853,5857,5860,6010,6017,6020,6024,6027,6075,6079,6156,6160,6188,6194],[11,4953,4955],{"id":4954},"welke-plaatsingswijzen-kent-het-arei-en-welke-hoort-in-het-eendraadschema","Welke plaatsingswijzen kent het AREI — en welke hoort in het eendraadschema?",[16,4957,4958,4959,4961,4962,27,4964,4967,4968,4971,4972,4975,4976,44],{},"Het AREI somt de toegelaten plaatsingswijzen voor laagspanningsleidingen limitatief op: zeventien letters van ",[20,4960,22],{}," tot ",[20,4963,26],{},[20,4965,4966],{},"onderafdeling 5.2.2.1.",", van luchtlijnen over ondergrondse plaatsing, opbouw, inbouw, plinten en goten tot verwarmingsleidingen in zolderingen en vloeren. Voor de meeste van die wijzen bevat ",[20,4969,4970],{},"afdeling 5.2.9."," bovendien eigen, bindende regels. En de gekozen wijze is geen interne aangelegenheid van de installateur: het eendraadschema van een huishoudelijke installatie moet naast type, doorsnede en aantal geleiders uitdrukkelijk ",[37,4973,4974],{},"de plaatsingswijze van de elektrische leidingen"," vermelden (",[20,4977,4978],{},"onderafdeling 3.1.2.2. punt a.",[16,4980,4981,4982,4985],{},"De reden staat elders in het reglement. De toelaatbare stroom IZ van een leiding is onder meer functie van „de plaatsing en de omgeving van de elektrische leiding” (",[20,4983,4984],{},"onderafdeling 4.4.1.4.","). Zonder de plaatsingswijze kun je dus niet beoordelen of een doorsnede bij de stroombaan past — daarom staat ze in het schema.",[53,4987,4988,5005],{},[56,4989,4990],{},[59,4991,4992,4996,4999,5002],{},[62,4993,2381,4994,68],{},[20,4995,3676],{},[62,4997,4998],{},"Plaatsingswijze",[62,5000,5001],{},"Typische toepassing in de woningbouw",[62,5003,5004],{},"Bijzondere regels",[79,5006,5007,5025,5041,5055,5069,5084,5099,5113,5128,5143,5158,5172,5186,5204,5220,5235,5249,5263,5278],{},[59,5008,5009,5011,5014,5017],{},[84,5010,22],{},[84,5012,5013],{},"luchtlijnen",[84,5015,5016],{},"voeding naar een bijgebouw",[84,5018,5019,5021,5022,68],{},[20,5020,3702],{}," (verwijst naar boek 3, ",[20,5023,5024],{},"hoofdstuk 7.1.",[59,5026,5027,5029,5032,5035],{},[84,5028,105],{},[84,5030,5031],{},"rechtstreeks ingegraven",[84,5033,5034],{},"tuinstopcontact, carport",[84,5036,5037,5040],{},[20,5038,5039],{},"5.2.9.2. punt a.",": minstens 0,60 m diep, enkel kabels",[59,5042,5043,5045,5048,5051],{},[84,5044,122],{},[84,5046,5047],{},"ingegraven met mechanische bescherming",[84,5049,5050],{},"kabel onder afdekband",[84,5052,5053],{},[20,5054,5039],{},[59,5056,5057,5059,5062,5065],{},[84,5058,137],{},[84,5060,5061],{},"ingegraven in een huls",[84,5063,5064],{},"doorgang onder oprit of terras",[84,5066,5067],{},[20,5068,5039],{},[59,5070,5071,5073,5076,5079],{},[84,5072,152],{},[84,5074,5075],{},"contactlijn voor rol- of glijcontacten",[84,5077,5078],{},"niet relevant in de woningbouw",[84,5080,5081],{},[20,5082,5083],{},"5.2.1.4. punt a.",[59,5085,5086,5088,5091,5094],{},[84,5087,168],{},[84,5089,5090],{},"in opbouw",[84,5092,5093],{},"zichtbare XVB in kelder, garage, techniek",[84,5095,5096,5098],{},[20,5097,3780],{},": enkel kabels; afstand tot de wand ≤ 0,3 × buitendiameter",[59,5100,5101,5103,5106,5109],{},[84,5102,185],{},[84,5104,5105],{},"in verzonken buizen",[84,5107,5108],{},"standaard bij nieuwbouw: VOB in preflex",[84,5110,5111],{},[20,5112,3796],{},[59,5114,5115,5117,5120,5123],{},[84,5116,201],{},[84,5118,5119],{},"in sierlijsten, plinten en lijsten",[84,5121,5122],{},"renovatie, zichtbare kabelgoot",[84,5124,5125,5127],{},[20,5126,3811],{},": enkel geïsoleerde geleiders of eenaderige kabels",[59,5129,5130,5132,5135,5138],{},[84,5131,218],{},[84,5133,5134],{},"in de vrije lucht met klemmen of op kabelrekken, kabelladders, kraagstukken, haken",[84,5136,5137],{},"technische ruimte, stookplaats",[84,5139,5140,5142],{},[20,5141,3780],{},": afstand tot alle wanden ≥ 0,3 × buitendiameter",[59,5144,5145,5147,5150,5153],{},[84,5146,234],{},[84,5148,5149],{},"in kabelbanen of goten",[84,5151,5152],{},"verdeeltracé in de technische ruimte",[84,5154,5155,5157],{},[20,5156,3842],{},": in open goten enkel kabels",[59,5159,5160,5162,5165,5168],{},[84,5161,251],{},[84,5163,5164],{},"in kokers",[84,5166,5167],{},"tracé boven de vloer",[84,5169,5170],{},[20,5171,3858],{},[59,5173,5174,5176,5179,5182],{},[84,5175,267],{},[84,5177,5178],{},"in open, gesloten of met zand gevulde kabelkanalen",[84,5180,5181],{},"vloerkanaal, industriële toepassing",[84,5183,5184],{},[20,5185,3873],{},[59,5187,5188,5190,5193,5196],{},[84,5189,283],{},[84,5191,5192],{},"in holle constructieruimten, holten en geprefabriceerde uitgeholde blokken",[84,5194,5195],{},"holle blokken, verlaagd plafond",[84,5197,5198,5200,5201],{},[20,5199,3888],{}," en ",[20,5202,5203],{},"4.3.3.5. punt b.",[59,5205,5206,5208,5211,5214],{},[84,5207,303],{},[84,5209,5210],{},"achter wandpanelen",[84,5212,5213],{},"gipskartonwand, houtskeletbouw",[84,5215,5216,5200,5218],{},[20,5217,3888],{},[20,5219,5203],{},[59,5221,5222,5224,5227,5230],{},[84,5223,320],{},[84,5225,5226],{},"rechtstreeks verzonken, zonder buizen",[84,5228,5229],{},"XVB rechtstreeks in de sleuf",[84,5231,5232,5234],{},[20,5233,3923],{},": gabarit, beton ≥ 3 cm, bepleistering ≥ 0,4 cm",[59,5236,5237,5239,5242,5245],{},[84,5238,337],{},[84,5240,5241],{},"in geprefabriceerde leidingen",[84,5243,5244],{},"zelden in de woningbouw",[84,5246,5247],{},[20,5248,3939],{},[59,5250,5251,5253,5256,5259],{},[84,5252,353],{},[84,5254,5255],{},"op isolatoren",[84,5257,5258],{},"bestaande oude installaties",[84,5260,5261],{},[20,5262,3954],{},[59,5264,5265,5267,5270,5273],{},[84,5266,16],{},[84,5268,5269],{},"onder water",[84,5271,5272],{},"zwembadtechniek",[84,5274,5275],{},[20,5276,5277],{},"5.2.2.1. punt p.",[59,5279,5280,5282,5285,5288],{},[84,5281,26],{},[84,5283,5284],{},"in zolderingen, vloeren en muren voor verwarmingsleidingen en -panelen",[84,5286,5287],{},"vloerverwarming, verwarmingsmatten",[84,5289,5290],{},[20,5291,3984],{},[16,5293,5294,5295,5298],{},"Andere plaatsingswijzen zijn niet verboden, maar vallen onder de restbepaling: ze beantwoorden aan „de desbetreffende regels van goed vakmanschap” (",[20,5296,5297],{},"onderafdeling 5.2.2.4.","). Wie buiten de lijst werkt, verlaat dus het gebied waarvoor het AREI zelf een regel formuleert.",[11,5300,5302],{"id":5301},"wat-is-het-verschil-tussen-punt-e-en-punt-m","Wat is het verschil tussen punt e en punt m?",[16,5304,5305,5306,5308,5309,5311,5312,5315],{},"Dit is het vaakst verwarde paar, want in de dagelijkse taal heet allebei „inbouw”. Het verschil is de buis. Punt ",[20,5307,185],{}," heet in de Nederlandse tekst letterlijk „in verzonken buizen” — de Franse tekst zegt „sous conduits encastrés”. Punt ",[20,5310,320],{}," heet daarentegen uitdrukkelijk „rechtstreeks verzonken, ",[37,5313,5314],{},"zonder"," buizen”.",[16,5317,5318,5319,5321,5322,5325,5326,5321,5328,5331,5332,5336],{},"Dat is geen woordenspel maar het verschil tussen twee regelsets. Voor ",[20,5320,185],{}," geldt ",[20,5323,5324],{},"onderafdeling 5.2.9.3."," met de buisregels: buigstralen, geleiders die altijd inschuifbaar en verwijderbaar blijven, geen verbindingen in de buis. Voor ",[20,5327,320],{},[20,5329,5330],{},"onderafdeling 5.2.9.10."," met het gabarit en de minimale bedekking. Welk materiaal je in welk geval kiest en wat dat kost, staat vergeleken in ",[22,5333,5335],{"href":5334},"\u002Fnl\u002Fblog\u002Fpreflex-vs-vrije-bedrading","preflex versus vrije bedrading","; dit artikel beschrijft de systematiek waarin beide varianten staan.",[11,5338,5340],{"id":5339},"waarom-bepaalt-de-plaatsingswijze-de-toelaatbare-stroom","Waarom bepaalt de plaatsingswijze de toelaatbare stroom?",[16,5342,5343,5346],{},[20,5344,5345],{},"Onderafdeling 4.4.1.4."," noemt vijf grootheden waarvan IZ afhangt. De plaatsingswijze is er één van, en het is de enige die je niet aan de kabel zelf kunt aflezen.",[53,5348,5349,5361],{},[56,5350,5351],{},[59,5352,5353,5358],{},[62,5354,5355,5356],{},"Grootheid volgens ",[20,5357,4051],{},[62,5359,5360],{},"Wat ze in het plan betekent",[79,5362,5363,5374,5382,5390,5399],{},[59,5364,5365,5368],{},[84,5366,5367],{},"doorsnede van de geleiders",[84,5369,5370,5371,68],{},"vermelding in het eendraadschema (",[20,5372,5373],{},"3.1.2.2. punt a.",[59,5375,5376,5379],{},[84,5377,5378],{},"isolatie van de geleiders",[84,5380,5381],{},"kabeltype, bijvoorbeeld XVB of VOB",[59,5383,5384,5387],{},[84,5385,5386],{},"samenstelling van de elektrische leiding",[84,5388,5389],{},"een- of meeraderig, wapening, scherm",[59,5391,5392,5395],{},[84,5393,5394],{},"plaatsing en omgeving van de leiding",[84,5396,5370,5397,68],{},[20,5398,5373],{},[59,5400,5401,5404],{},[84,5402,5403],{},"omgevingstemperatuur",[84,5405,5406,5407],{},"waar de leiding ligt, zie ",[20,5408,4103],{},[16,5410,5411,5412,5414],{},"De eigenlijke berekening staat niet in het AREI. De tekst zegt enkel dat de toelaatbare stroom „volgens de regels van goed vakmanschap” berekend moet worden (",[20,5413,4051],{},") en dat de bevoegde ministers daarvoor nadere regels kunnen vaststellen. In de praktijk komen de tabellen en correctiefactoren dus uit de normenreeks NBN HD 60364-5-52, niet uit het AREI zelf.",[16,5416,5417,5418,5421,5422,5424,5425,5428,5429,971],{},"Wat het AREI wél vastlegt, wordt daar vaak mee verward: ",[20,5419,5420],{},"tabel 4.11."," geeft voor huishoudelijke installaties de ",[37,5423,528],{}," nominale stroom per doorsnede, apart voor de smeltzekering en voor de vermogensschakelaar: bij 1,5 mm² 10 A respectievelijk 16 A, bij 2,5 mm² 16 A respectievelijk 20 A, bij 4 mm² 20 A respectievelijk 25 A, bij 6 mm² 32 A respectievelijk 40 A, bij 10 mm² 50 A respectievelijk 63 A. Die tabel kent de plaatsingswijze niet. Ze is een bovengrens, geen vrijgeleide: de voorwaarde IZ ≥ IB uit ",[20,5426,5427],{},"onderafdeling 5.2.1.2. punt a."," moet daarnaast vervuld zijn. De koppeling doorsnede-beveiliging staat uitgewerkt in ",[22,5430,5432],{"href":5431},"\u002Fnl\u002Fblog\u002Fkabeldoorsnede-automaat","kabeldoorsnede en automaat",[11,5434,5436],{"id":5435},"wat-doen-bundeling-omgevingstemperatuur-en-isolatiemateriaal-met-de-belastbaarheid","Wat doen bundeling, omgevingstemperatuur en isolatiemateriaal met de belastbaarheid?",[16,5438,5439],{},"Alle drie verlagen ze IZ, en in alle drie de gevallen levert het AREI de randvoorwaarde, niet de factor.",[16,5441,5442,5445,5446,5449,5450,5453,5454,5457,5458,5461],{},[37,5443,5444],{},"Bundeling."," Het AREI legt de grens exact vast: een kabel of geïsoleerde geleider is ",[37,5447,5448],{},"afzonderlijk geïnstalleerd"," wanneer hij op minstens 20 mm van elke andere kabel of geïsoleerde geleider ligt (",[20,5451,5452],{},"afdeling 2.7.1.","). Alles daaronder is „in bundel of in laag” geplaatst. Dat onderscheid heeft in het AREI een rechtstreeks gevolg — maar voor de brandvoortplanting, niet voor de opwarming: afzonderlijk geplaatste geleiders en kabels hebben minstens de karakteristiek F1 of klasse Eca (",[20,5455,5456],{},"onderafdeling 5.2.7.2.","), in bundel of in laag minstens F2 of klasse Cca (",[20,5459,5460],{},"onderafdeling 5.2.7.3.","), en dat „onafhankelijk van de afstand waarover ze effectief in bundel of laag geïnstalleerd zijn”. De thermische bundelingsfactor zelf volgt opnieuw uit de regels van goed vakmanschap.",[16,5463,5464,573,5467,5470,5471,5474],{},[37,5465,5466],{},"Omgevingstemperatuur.",[20,5468,5469],{},"Onderafdeling 5.2.3.1."," eist dat leidingen geschikt zijn voor de laagste en de hoogste plaatselijke omgevingstemperatuur en enkel binnen het door de fabrikant opgegeven temperatuurbereik geplaatst worden. Daar komt ",[20,5472,5473],{},"afdeling 5.2.8."," bij: leidingen mogen in de buurt van verwarmings- of warmeluchtleidingen en rookafvoeren niet aan schadelijke temperaturen blootgesteld worden en moeten voldoende afstand houden of door een warmteschild gescheiden zijn. Wie een leiding vlak naast de verwarmingscollector legt, verandert daarmee haar thermische omgeving — en die maakt deel uit van dezelfde vermelding als de plaatsingswijze.",[16,5476,5477,5480,5481,5484,5485,5487,5488,5491,5492,5494],{},[37,5478,5479],{},"Thermische isolatie."," Hier hoort een eerlijke vaststelling: het AREI bevat ",[37,5482,5483],{},"geen"," eigen reductiefactor voor leidingen in of onder isolatiemateriaal. „Thermische isolatie” komt in het reglement voor als voorzorg bij temperaturen onder −25 °C (",[20,5486,4103],{},") en in het hoofdstuk over verwarmingspanelen, waar isolatiemateriaal in contact met de verwarmingsinstallatie onbrandbaar moet zijn (",[20,5489,5490],{},"5.2.9.13. punt b.5.","). Een leiding in een geïsoleerd hellend dak valt dus onder „plaatsing en omgeving” van ",[20,5493,4051],{}," en wordt beoordeeld volgens de regels van goed vakmanschap — niet volgens een AREI-tabel die niet bestaat.",[11,5496,5498],{"id":5497},"waar-hoort-de-plaatsingswijze-thuis-eendraadschema-situatieplan-of-materiaallijst","Waar hoort de plaatsingswijze thuis: eendraadschema, situatieplan of materiaallijst?",[16,5500,5501],{},"Die drie documenten hebben in het AREI duidelijk gescheiden verplichte inhoud.",[53,5503,5504,5516],{},[56,5505,5506],{},[59,5507,5508,5510,5513],{},[62,5509,2899],{},[62,5511,5512],{},"Plaatsingswijze vereist?",[62,5514,5515],{},"Vindplaats",[79,5517,5518,5532,5549,5564],{},[59,5519,5520,5523,5528],{},[84,5521,5522],{},"eendraadschema (huishoudelijk)",[84,5524,5525,5527],{},[37,5526,635],{},", uitdrukkelijk",[84,5529,5530],{},[20,5531,5373],{},[59,5533,5534,5537,5544],{},[84,5535,5536],{},"situatieplan (huishoudelijk)",[84,5538,5539,5540,5543],{},"nee — daar staat de ",[37,5541,5542],{},"plaats"," van de onderdelen",[84,5545,5546],{},[20,5547,5548],{},"3.1.2.3. punt a.",[59,5550,5551,5554,5559],{},[84,5552,5553],{},"stroombaanschema (niet-huishoudelijk)",[84,5555,5556,5558],{},[37,5557,635],{},", samen met lengte en aantal geleiders",[84,5560,5561],{},[20,5562,5563],{},"3.1.2.2. punt b.",[59,5565,5566,5569,5572],{},[84,5567,5568],{},"materiaallijst",[84,5570,5571],{},"niet voorgeschreven",[84,5573,5574,5575],{},"toegelaten als bijlage bij ",[20,5576,5577],{},"3.1.2.1. punt c.",[16,5579,5580,5581,5584],{},"De materiaallijst is in het AREI geen verplicht document. ",[20,5582,5583],{},"Onderafdeling 3.1.2.1. punt c."," laat enkel toe schema’s en plannen aan te vullen met documenten „waarin de verschillende kenmerken van het elektrisch materieel en\u002Fof de producten nader beschreven worden”. Een kabellijst met de plaatsingswijze per leiding is precies zo’n bijlage: nuttig voor calculatie en uitvoering, maar ze ontslaat je niet van de vermelding in het eendraadschema zelf.",[16,5586,5587,5588,5592],{},"Hoe schema en situatieplan zich verder verdelen, staat in ",[22,5589,5591],{"href":5590},"\u002Fnl\u002Fblog\u002Fkabelwegen-en-kabellengtes-bepalen","kabelwegen en kabellengtes","; daar lees je ook waarom de lengte enkel in het niet-huishoudelijke stroombaanschema verplicht is.",[11,5594,5596],{"id":5595},"wanneer-verandert-de-plaatsingswijze-binnen-één-leiding","Wanneer verandert de plaatsingswijze binnen één leiding?",[16,5598,5599,5600,5603,5604,44],{},"Een leiding heeft zelden maar één plaatsingswijze. Van het bord door de muur, over het plafond, de grond in en weer tegen een buitenmuur: dat zijn er vier. Het AREI heeft daar een eigen begrip voor. Als ",[37,5601,5602],{},"begin van een stroombaan"," geldt het begin van de elektrische leiding „hetzij de plaats waar de doorsnede, aard of samenstelling van de elektrische leiding of haar plaatsingswijze verandert” (",[20,5605,5606],{},"afdeling 2.6.1.",[16,5608,5609],{},"Praktisch betekent dat: elke wissel van plaatsingswijze is een eigen beschouwingstraject. Voor de dimensionering telt het ongunstigste — een leiding die twee meter door een bundel buizen loopt en daarna vrij in het plafond ligt, wordt niet op het vrije stuk gedimensioneerd. Voor het schema betekent het: alle voorkomende wijzen horen gedocumenteerd, niet alleen de langste.",[11,5611,5613],{"id":5612},"welke-regels-gelden-voor-verzonken-leidingen","Welke regels gelden voor verzonken leidingen?",[16,5615,5616,5617,5620,5621,5623],{},"Voor de rechtstreekse plaatsing zonder buis (",[20,5618,5619],{},"punt m",") is ",[20,5622,5330],{}," de maatgevende bepaling, en ze is ongewoon concreet.",[16,5625,735,5626,5629,5630,44],{},[37,5627,5628],{},"beton of cement"," verzonken leidingen worden bedekt met een laag beton of cement van minstens 3 cm; geleiders met enkel basisisolatie mogen er helemaal niet in verzonken worden (",[20,5631,5632],{},"punt a.",[16,5634,5635,5636,5639,5640,752],{},"Leidingen die zonder buis ",[37,5637,5638],{},"in de muren van lokalen"," verzonken worden, moeten daarnaast binnen het gabarit blijven (",[20,5641,5642],{},"punt b.",[754,5644,5645,5648,5651,5654,5657,5660],{},[757,5646,5647],{},"het traject volgt alleen horizontale en verticale wegen; horizontale wegen in een plafond staan haaks op de verticale wanden;",[757,5649,5650],{},"horizontale trajecten bevinden zich op 25 à 35 cm van de vloer of het plafond, en eveneens op 25 à 35 cm boven de onderkant van de bovendrempel van het raam, voor zover ze dan minstens 25 cm onder het plafond blijven;",[757,5652,5653],{},"verticale trajecten liggen zo dicht mogelijk in een hoek van het lokaal of op 10 à 20 cm van de lijsten of kozijnen van de deuren;",[757,5655,5656],{},"buiten dit gabarit mag enkel verticaal ten opzichte van een zichtbaar toestel geplaatst worden;",[757,5658,5659],{},"de leidingen worden noch bij de plaatsing noch later aan mechanische invloeden onderworpen en zonder beschadiging aan de wanden gehecht;",[757,5661,5662],{},"de dekkende bepleistering is minstens 0,4 cm dik.",[16,5664,5665,5666,5668,5669,5672,5673,5676,5677,5680,5681,44],{},"Voor buizen geldt in de plaats daarvan ",[20,5667,5324],{},": geleiders of kabels moeten altijd ingeschoven en verwijderd kunnen worden (",[20,5670,5671],{},"punt e.","), verbindingen in de buis zijn verboden (",[20,5674,5675],{},"punt f.","), en in ingebouwde buizen zijn T-stukken en hoekstukken niet toegelaten terwijl de geleiders in verbindings-, aftak- en trekdozen toegankelijk blijven (",[20,5678,5679],{},"punt i.2.","). Buizen uit brandbaar materiaal mogen enkel gebruikt worden als ze minstens 3 cm diep in onbrandbaar materiaal zitten (",[20,5682,5675],{},[16,5684,5685,5686,5689,5690,5693,5694,5697,5698,5700],{},"Eén belangrijke uitzondering: voor ",[37,5687,5688],{},"installaties op zeer lage spanning"," geldt het gabarit van ",[20,5691,5692],{},"5.2.9.10. punt b."," uitdrukkelijk niet (",[20,5695,5696],{},"onderafdeling 5.2.9.15. punt b.","). Bus-, bel- en stuurleidingen op ZLS moeten dus niet in het zonepatroon blijven — de overige regels van ",[20,5699,4970],{}," blijven wel van toepassing.",[11,5702,5704],{"id":5703},"wat-geldt-voor-ondergrondse-leidingen","Wat geldt voor ondergrondse leidingen?",[16,5706,5707,5710,5711,5714],{},[20,5708,5709],{},"Onderafdeling 5.2.9.2. punt a."," is een van de scherpste bepalingen van het hoofdstuk. In de grond en in ontoegankelijke ondergrondse hulzen mogen — met uitzondering van onafhankelijke beschermingsgeleiders — ",[37,5712,5713],{},"enkel kabels"," geplaatst worden. De minimale diepte is 0,60 m, gemeten vanaf het grondvlak, „behalve indien het technisch onmogelijk is”. Kan die diepte niet gehaald worden, dan komt er een doorlopend of afgedicht omhulsel in duurzaam en weerstandbiedend materiaal in de plaats.",[16,5716,5717],{},"Bovendien moet de kabel aan één van drie voorwaarden voldoen: een geaard elektrisch scherm met wapening of versterkte buitenmantel; of een weerstandbiedende buitenmantel plus een doorlopende afdekking die bij graafwerken beschermt en aan beide zijden uitsteekt; of plaatsing in een huls dan wel een gelijkwaardig systeem. Is aan één daarvan voldaan, dan zijn voor de bescherming tegen elektrische schokken geen bijkomende maatregelen vereist.",[16,5719,5720,5721,5724],{},"Voor de signalisatie in de grond bevat ",[20,5722,5723],{},"punt d."," eigen regels: merktekens aan de uiteinden van rechte stukken, minstens om de tweehonderd meter, met een oppervlakte van minstens 0,01 m² en een bliksemschicht in reliëf. Aansluitingen van laagspanningsnetgebruikers zijn daarvan vrijgesteld.",[11,5726,5728],{"id":5727},"welke-kabel-mag-in-welke-plaatsingswijze","Welke kabel mag in welke plaatsingswijze?",[16,5730,5731],{},"De plaatsingswijze beperkt de kabelkeuze, los van de doorsnede.",[53,5733,5734,5745],{},[56,5735,5736],{},[59,5737,5738,5740,5743],{},[62,5739,4998],{},[62,5741,5742],{},"Toegelaten",[62,5744,5515],{},[79,5746,5747,5758,5769,5780,5792,5804,5816],{},[59,5748,5749,5752,5754],{},[84,5750,5751],{},"ondergronds",[84,5753,5713],{},[84,5755,5756],{},[20,5757,4456],{},[59,5759,5760,5763,5765],{},[84,5761,5762],{},"in de vrije lucht en in opbouw",[84,5764,5713],{},[84,5766,5767],{},[20,5768,3780],{},[59,5770,5771,5774,5776],{},[84,5772,5773],{},"open goot",[84,5775,5713],{},[84,5777,5778],{},[20,5779,3842],{},[59,5781,5782,5785,5788],{},[84,5783,5784],{},"gesloten goot",[84,5786,5787],{},"ook geïsoleerde geleiders; buiten de lokalen van de elektrische dienst volwandig en met deksel dat enkel met gereedschap opengaat",[84,5789,5790],{},[20,5791,3842],{},[59,5793,5794,5797,5800],{},[84,5795,5796],{},"sierlijsten, plinten en lijsten",[84,5798,5799],{},"geïsoleerde geleiders of eenaderige kabels",[84,5801,5802],{},[20,5803,4503],{},[59,5805,5806,5809,5812],{},[84,5807,5808],{},"buizen",[84,5810,5811],{},"geïsoleerde geleiders of kabels",[84,5813,5814],{},[20,5815,4515],{},[59,5817,5818,5821,5824],{},[84,5819,5820],{},"holle constructieruimten",[84,5822,5823],{},"geen geleiders met enkel basisisolatie",[84,5825,5826],{},[20,5827,3888],{},[16,5829,5830,5831,5833,5834,5837,5838,5841,5842,5844,5845,5848,5849,971],{},"Daar komt de brandklasse bij. In ",[37,5832,5820],{}," en in ",[37,5835,5836],{},"sierlijsten, plinten of lijsten uit brandbare materialen"," eist ",[20,5839,5840],{},"onderafdeling 4.3.3.5. punt b."," uitdrukkelijk de karakteristiek of klasse van ",[20,5843,4544],{}," — dus F2 of minstens Cca. Een houtskeletwand is een holle constructieruimte. Welk kabeltype bij welke toepassing hoort, staat in ",[22,5846,3241],{"href":5847},"\u002Fnl\u002Fblog\u002Fxvb-vs-vob-kabel","; voor natte ruimten gelden bovendien de volumeregels uit ",[22,5850,5852],{"href":5851},"\u002Fnl\u002Fblog\u002Fbadkamer-kabels-arei-zones","badkamerkabels en AREI-zones",[11,5854,5856],{"id":5855},"hoe-legt-planelec-de-plaatsingswijze-vast-en-wat-staat-er-in-de-export","Hoe legt PlanElec de plaatsingswijze vast, en wat staat er in de export?",[16,5858,5859],{},"PlanElec kent twaalf voor de woningbouw relevante plaatsingswijzen en houdt bij elke wijze de AREI-verwijzing bij waaronder ze valt:",[53,5861,5862,5875],{},[56,5863,5864],{},[59,5865,5866,5869,5872],{},[62,5867,5868],{},"Keuze in PlanElec",[62,5870,5871],{},"Korte code",[62,5873,5874],{},"Vastgelegde AREI-verwijzing",[79,5876,5877,5888,5901,5912,5923,5934,5945,5956,5967,5977,5988,5999],{},[59,5878,5879,5882,5884],{},[84,5880,5881],{},"opbouw",[84,5883,1003],{},[84,5885,5886],{},[20,5887,4590],{},[59,5889,5890,5893,5895],{},[84,5891,5892],{},"leiding in buis op de wand",[84,5894,1016],{},[84,5896,5897,1021,5899],{},[20,5898,4590],{},[20,5900,4604],{},[59,5902,5903,5906,5908],{},[84,5904,5905],{},"inbouw in flexibele buis",[84,5907,1032],{},[84,5909,5910],{},[20,5911,4616],{},[59,5913,5914,5917,5919],{},[84,5915,5916],{},"inbouw direct",[84,5918,1045],{},[84,5920,5921],{},[20,5922,4628],{},[59,5924,5925,5928,5930],{},[84,5926,5927],{},"in buis",[84,5929,1058],{},[84,5931,5932],{},[20,5933,3796],{},[59,5935,5936,5939,5941],{},[84,5937,5938],{},"bundel van buizen",[84,5940,1070],{},[84,5942,5943],{},[20,5944,3796],{},[59,5946,5947,5950,5952],{},[84,5948,5949],{},"holle wand \u002F wandplaat",[84,5951,1082],{},[84,5953,5954],{},[20,5955,4662],{},[59,5957,5958,5961,5963],{},[84,5959,5960],{},"plint \u002F kabelgoot",[84,5962,1095],{},[84,5964,5965],{},[20,5966,4674],{},[59,5968,5969,5971,5973],{},[84,5970,5751],{},[84,5972,1108],{},[84,5974,5975],{},[20,5976,4685],{},[59,5978,5979,5982,5984],{},[84,5980,5981],{},"ondergronds in kabelbuis",[84,5983,1121],{},[84,5985,5986],{},[20,5987,4697],{},[59,5989,5990,5993,5995],{},[84,5991,5992],{},"kabelgoot \u002F -ladder",[84,5994,1134],{},[84,5996,5997],{},[20,5998,4709],{},[59,6000,6001,6004,6006],{},[84,6002,6003],{},"vrij in plafond of holte",[84,6005,1147],{},[84,6007,6008],{},[20,6009,4721],{},[16,6011,6012,6013,6016],{},"De plaatsingswijze hangt aan het deeltraject, niet aan de hele kabel: een kabelroute in het grondplan kan per stuk een andere wijze dragen, en elk deeltraject krijgt zijn eigen kleur met de tweeletterige code. In het eendraadschema wordt standaard ",[37,6014,6015],{},"één"," maatgevende wijze getekend — de meest restrictieve van de voorkomende. Wijzen waarvoor in het gereedschap geen betrouwbare referentietabel bestaat, krijgen daarbij bewust voorrang in plaats van verborgen te worden achter een verzonnen thermische rangorde.",[16,6018,6019],{},"Sinds de update van 28 augustus 2026 kun je leidingen in buis, bundels van buizen, ondergrondse leidingen in kabelbuis en buizen op de wand afzonderlijk kiezen; elke plaatsingswijze draagt in kabelmenu, editor, voorbeeld en pdf hetzelfde volledige teken met zijn eigen draaglijn. Die draaglijn is precies waarom opbouw en inbouw van elkaar te onderscheiden zijn: ze stelt de geleider voor, en of de muurtekens erboven of eronder liggen ís de uitspraak. Sinds 29 augustus 2026 klik je de plaatsingswijze rechtstreeks in het schema aan; het kabelmenu verschijnt op de gekozen plek en blijft daarnaast bereikbaar in het eigenschappenpaneel. In de kabellijst verschijnt ze als aparte kolom „Installatiemethode”.",[11,6021,6023],{"id":6022},"wat-de-arei-zelfcontrole-hierover-niet-doet","Wat de AREI-zelfcontrole hierover niet doet",[16,6025,6026],{},"De zelfcontrole is oriënterend. Voor de plaatsingswijze betekent dat concreet:",[754,6028,6029,6039,6047,6057,6062],{},[757,6030,6031,6032,6035,6036,6038],{},"Ze controleert ",[37,6033,6034],{},"niet"," de toelaatbare stroom bij de ingevoerde plaatsingswijze. Wat gecontroleerd wordt, is of de kabeldoorsnede bij de nominale stroom van de beveiliging past — dat is de koppeling uit ",[20,6037,5420],{},", en die kent de plaatsingswijze niet. Bundeling, omgevingstemperatuur en isolatiemateriaal spelen in geen enkele controle mee.",[757,6040,6031,6041,6043,6044,6046],{},[37,6042,6034],{}," of het gabarit van ",[20,6045,5692],{}," gerespecteerd is, of de bepleistering en de betonbedekking dik genoeg zijn, of een ondergrondse leiding diep genoeg ligt. Dat zijn maten op de werf, geen gegevens in het model.",[757,6048,6031,6049,6051,6052,1021,6054,6056],{},[37,6050,6015],{}," plaatsingsafhankelijke regel: kabels in holle constructieruimten moeten in een buis liggen of minstens klasse Cca halen (",[20,6053,5203],{},[20,6055,4544],{},"). Ontbreekt de brandklasse, dan meldt PlanElec een gegevenslacune in plaats van een fout; ligt ze onder Cca zonder gedocumenteerde buis, dan is het een fout.",[757,6058,6031,6059,6061],{},[37,6060,6034],{}," of de ingevoerde plaatsingswijze overeenkomt met wat er nadien werkelijk geplaatst is. Dat is een visuele vaststelling ter plaatse.",[757,6063,6064,6065,6067,6068,6070,6071,971],{},"Ze vervangt ",[37,6066,1214],{}," meting ",[37,6069,1214],{}," keuring; de officiële beoordeling gebeurt uitsluitend door een erkend organisme. De volledige omvang staat in ",[22,6072,6074],{"href":6073},"\u002Fnl\u002Fhelp\u002Fwat-controleert-de-zelfcontrole","wat de zelfcontrole controleert",[11,6076,6078],{"id":6077},"welke-fouten-vallen-op-bij-de-keuring","Welke fouten vallen op bij de keuring?",[754,6080,6081,6093,6101,6110,6120,6129,6139,6147],{},[757,6082,6083,6086,6087,6089,6090,6092],{},[37,6084,6085],{},"Geïsoleerde geleiders in plaats van kabels in opbouw of in een open goot."," Losse VOB-aders zichtbaar tegen de muur of in een goot zijn in strijd met ",[20,6088,3780],{}," respectievelijk ",[20,6091,3842],{},": daar zijn uitsluitend kabels toegelaten.",[757,6094,6095,6098,6099],{},[37,6096,6097],{},"Sleuf buiten het gabarit."," Diagonale trajecten en verlopen dwars door het midden van de muur zijn de klassieker bij ",[20,6100,5692],{},[757,6102,6103,6106,6107,44],{},[37,6104,6105],{},"Te dunne bedekking."," Minder dan 0,4 cm bepleistering boven de leiding of minder dan 3 cm beton bij ingegoten leidingen (",[20,6108,6109],{},"5.2.9.10. punten a. en b.",[757,6111,6112,6115,6116,6119],{},[37,6113,6114],{},"Verbinding in de buis."," Klemmen en lasdoppen in een buis zijn verboden (",[20,6117,6118],{},"5.2.9.3. punt f.","); aansluitingen in trek- en verbindingsdozen horen op een geschikt klemmenblok.",[757,6121,6122,6125,6126,44],{},[37,6123,6124],{},"Buis niet meer natrekbaar."," Te scherpe bochten of overvolle buizen schenden de eis dat geleiders altijd ingeschoven en verwijderd kunnen worden (",[20,6127,6128],{},"5.2.9.3. punt e.",[757,6130,6131,6134,6135,1021,6137,44],{},[37,6132,6133],{},"Holte met Eca in plaats van Cca en zonder buis."," Een frequente bevinding in houtbouw en verlaagde plafonds (",[20,6136,5203],{},[20,6138,4544],{},[757,6140,6141,6144,6145,44],{},[37,6142,6143],{},"Ondergrondse kabel te ondiep."," Minder dan 0,60 m zonder doorlopend beschermingsomhulsel (",[20,6146,5039],{},[757,6148,6149,6152,6153,6155],{},[37,6150,6151],{},"Plaatsingswijze ontbreekt in het schema."," Een eendraadschema met type, doorsnede en aantal geleiders maar zonder plaatsingswijze is onvolledig (",[20,6154,5373],{},") — hoe netjes de installatie ook uitgevoerd is.",[11,6157,6159],{"id":6158},"verder-lezen","Verder lezen",[754,6161,6162,6167,6172,6177,6182],{},[757,6163,6164],{},[22,6165,6166],{"href":5431},"Kabeldoorsnede en automaat",[757,6168,6169],{},[22,6170,6171],{"href":5590},"Kabelwegen en kabellengtes",[757,6173,6174],{},[22,6175,6176],{"href":5847},"XVB versus VOB: welke kabel waarvoor",[757,6178,6179],{},[22,6180,6181],{"href":5334},"Preflex versus vrije bedrading",[757,6183,6184],{},[22,6185,6187],{"href":6186},"\u002Fnl\u002Fblog\u002Feendraadschema-maken","Eendraadschema maken: stap voor stap",[16,6189,6190],{},[22,6191,6193],{"href":6192},"\u002Fnl","PlanElec openen en plaatsingswijzen invullen →",[16,6195,6196],{},[20,6197,6198],{},"Reglementaire basis: AREI\u002FRGIE boek 1 V06 — afdelingen 2.6.1., 2.7.1., 2.7.2., 5.2.2., 5.2.8., onderafdelingen 3.1.2.1., 3.1.2.2., 3.1.2.3., 4.3.3.5., 4.4.1.4. met tabel 4.11., 5.2.1.2., 5.2.3.1., 5.2.7.2., 5.2.7.3. en afdeling 5.2.9. met de onderafdelingen 5.2.9.1. tot 5.2.9.15. De officiële tekst, de werkelijke toestand van de installatie en het oordeel van het erkende organisme blijven doorslaggevend.",{"title":1342,"searchDepth":1343,"depth":1343,"links":6200},[6201,6202,6203,6204,6205,6206,6207,6208,6209,6210,6211,6212,6213],{"id":4954,"depth":1343,"text":4955},{"id":5301,"depth":1343,"text":5302},{"id":5339,"depth":1343,"text":5340},{"id":5435,"depth":1343,"text":5436},{"id":5497,"depth":1343,"text":5498},{"id":5595,"depth":1343,"text":5596},{"id":5612,"depth":1343,"text":5613},{"id":5703,"depth":1343,"text":5704},{"id":5727,"depth":1343,"text":5728},{"id":5855,"depth":1343,"text":5856},{"id":6022,"depth":1343,"text":6023},{"id":6077,"depth":1343,"text":6078},{"id":6158,"depth":1343,"text":6159},"De zeventien plaatsingswijzen van onderafdeling 5.2.2.1, hun bijzondere regels in afdeling 5.2.9, de invloed op de toelaatbare stroom en waar de vermelding verplicht thuishoort — met het AREI-artikel bij elke uitspraak.","nl",{},"\u002Fblog\u002Finstallation-methods-arei.nl",{"title":4949,"description":6214},"plaatsingswijzen-arei-eendraadschema","blog\u002Finstallation-methods-arei.nl",[1372,1373,6222,6223,6224,6225,6226,6227],"plaatsingswijzen","eendraadschema","toelaatbare stroom","kabelplaatsing","installatiezones","België","jvJcit6gofVNcTqmokHBgXiKFRmCT2Kk3zgnpSJ4Sk0",1788389240417]